Operating Instructions Switch Butler DSE 409S
Contents
1. Operating Instructions Switch Butler DSE 409S For your safety Do not fail to read before putting into operation Models Digital operation Type 889 400 for 230VAC Introduction Dear customer As with all electrical equipment also with this appliance special care is called for to avoid injuries fire or equipment damage Please study these operating instructions before putting the appliance into operation and comply with the safety remarks Use of the Operating Instructions These operating instructions cannot take every conceivable application into consideration For addi tional information or in case of problems which are not dealt with in sufficient detail in these operating instructions please consult your specialist dealer Keep these operating instructions carefully and if so required pass them on to any later users General Description The Switch Butler DSE 409 utilizes the public telephone network in conjunction with a paging network for controlling electrical consumer equipment There is no fixed subscription fee The DSE 409 oper ates in accordance with the minicall principle in which only the call is subject to a charge Required for operation is a tone dial telephone with the keys and The number of the Swissphone Paging Service is 0900 104 055 The Switch Butler is supplied with pre programmed call number and PIN code After dialling the paging centre enter the call number of the DSE 409 and confirm wi
2. conds 1 99 first 00 and then the numbers cor responding to the number of seconds are dialled For programming a continuous relay operation the numbers for the time indications are left out Programming A message is built up as follows 1 Dial the paging centre telephone number 0900 104 055 wait for the text message 2 Enter the call number confirm with wait for the text message 3 Enter the PIN code relay number s relay function ON OFF and the switching on duration Confirm with and hang up the phone The call number Call No and the PIN code you will find on the name plate of the appliance Example 1 Dial the number of the paging centre 0900 104 055 2 Wait for the text message 3 Enter the call number Call No of your DSE 409 and confirm with Wait for the text message and enter the PIN code followed by the corresponding message Confirm with and hand up the phone 1 Relay 1 is to be activated for 2 hours Number sequence PIN code 1 1 2 2 Relay 2 is to be activated for 20 minutes Number sequence PIN code 2 1 020 3 Relay 3 is to be activated for 30 seconds Number sequence PIN code 3 1 0030 4 Relay 1 is to be continuously activated Number sequence PIN code 1 1 5 Relay 1 is to be de activated Number sequence PIN code 1 0 6 Relays 1 3 are to be activated for 1 minute Number sequence PIN code 41 01 7 Relays 2 3 are to be activated for 1 second Number sequenc
3. e PIN code 5 1 001 The relay operating conditions On Off of the DSE 409 are indicated by means of LEDs The LEDs in case of activated relays are lit red and are extinguished in case of de activated relays When the power supply is switched on the corresponding LED is lit green O In case of traffic via the paging system the corresponding relay is intermittently lit orange Schematic connection diagram Output 1 Output 2 Output 3 NO C NC NO C NC NO C NC NO Normally open C Common NG Normally closed 230 V AC Phase Neutral Safety Regulations Danger Electric current can be fatal Never let the SwitchPager come into contact with water or other liquids Danger of a short circuit Not authorized operators Persons who are not familiar with the operating instructions children as well as persons under the influence of alcohol or drugs must not operate the SwitchPager or else only under supervision Additional Regulations The user has the responsibility to ensure that appliances connected to the remote switch do not cause any damage The user is responsible for ensuring that in case of a malfunction of the remote switch no damage is caused Itis not permitted to connect electrical appliances which must only be operated under supervision Guarantee Any damage problems which are attributable to disturbances faults of the paging network are not subject to the appliance guarantee The guarantee
4. services are limited to the material value of the remote switch The duration of the guarantee is 12 months as from the date of purchase The guarantee becomes null and void if the appliance is opened by an unauthorized person Technical Data of the DSE 409S HF part POCSAG standard Frequency ranges 130 170 MHz 275 300 MHz 440 470 MHz Transmission speeds 512 1200 2400 Baud Dimensions 90 mm x 72 mm x 60 mm 4 modules standard DIN construction Weight approx 300 g BNC aerial connector plug with 50 Q impedance Electric power supply 230 VAC 10 50 60 Hz 25 VA Current demand in standby operation 30 mA Current demand with all relays activated 110 mA Output relays Relay contact load 230 VAC 10 A Electric power failure In case of an electric power failure the backup period for all static values amounts to 200 h the timer functions are lost Ambient Operating temperature range 20 40 C Relative humidity 5 95 without any condensation Remark The operation of the device can be influenced by powerful magnetic fields The following precautionary measures are to be implemented Do not install the DSE 409 in the vicinity of powerful inductive loads If necessary utilize line filters Select a suitable location for the aerial The DSE 409 must not be installed inside a closed metallic housing If this is unavoidable the aerial has to be brought to the exterior through a suitable line coa
5. th the key Then enter the 4 digit PIN code followed by the control code of the required relay output Complete the process by pushing the key Depending on the current traffic load in the paging network the DSE 409 receives the message within 120 seconds and controls the relay output or outputs In the immediate vicinity of the DSE 409 the switching noise of the relay can be heard and the lighting up of the corresponding LED observed The DSE 409 has three potential free individually controllable switching contacts refer to the sche matic diagram The relay contacts can be activated individually in pairs or all together The duration of operation can be activated in seconds minutes and hours 1 99 or as a permanent switching on or off The individual relays are controlled in accordance with the following scheme Relay 1 dial number 1 Relays 1 and 3 dial number 4 Relay 2 dial number 2 Relays 2 and 3 dial number 5 Relay 3 dial number 3 Relays 1 and 2 dial number 6 All relays together dial number 7 Programming the relay contacts Number 1 On Number 0 Off For programming a duration of operation in hours 1 99 the numbers corresponding to the number of hours are dialled For programming a duration of operation in minutes 1 99 first 0 and then the numbers corre sponding to the number of minutes are dialled For programming a duration of operation in se
6. xial cable RG58 509 If you should have any technical questions or reception problems please directly contact the company Elbro AG Phone 01 854 73 00 Fax 01 8547301 Elbro AG Gewerbestrasse 4 Postfach 11 CH 8162 Steinmaur