INSTALLATION MANUAL FOR ILB HELIOS
Contents
1. d Grounding Module frames and mounting racks must be properly grounded in accordance to local and national electrical codes before wiring the circuit in order to avoid electrical shock For a proper grounding connect in the first step all module frames in series with a proper grounding conductor Secondly connect this conductor to the supporting frame and then to the other supporting members of the installation creating a ring this ring has then to be grounded at 2 or 3 points ILB HELIOS PV module frames is equipped with a ground mark and a 4mm diameter hole Attach the grounding cable by first stripping about 10 to 15mm of the insulation from the end of the conductor and passing the bare wire in between the head of a stainless steel screw DIN 933 A2 M4x20 and a pressure and dented washer DIN 6798 A A2 M4 to break the frame anodization Finally tighten the nut DIN 934 A2 M4 AU DIN 933 M4x20 bolt DIN 6798 M4 dented washer Grounding wirer DIN 934 M4 nut Fig 4 Grounding Connection MN After you have attached the grounding cable please check the function of the grounding S ECE ILB Helios AG ILB International Logistikbetriebe AG Bruggerstrasse 71 CH 5401 Baden Phone 41 56 205 30 60 Fax 41 56 210 02 28 8 14 www ilb helios group ch Copyright 2009 ILB Helios AG Specifications are subject to change without prior note ILB Helios is not responsible for spelling mistakes or miss
2. ILB HELIOS photovoltaic modules are qualified for Application Class A Hazardous voltage IEC 61730 higher than 50V DC EN 61730 higher than 120V DC hazardous power applications higher than 240W where general contact access is anticipated ILB HELIOS photovoltaic modules qualified for safety through EN IEC 61730 1 and 2 within this application class are considered to meet the requirements for Safety Class ll Under normal conditions a photovoltaic module is likely to experience conditions that produce more current and or voltage than reported at standard test conditions Accordingly the values of Isc and Voc marked on this module should be multiplied by a factor of 1 25 when determining component voltage ratings conductor current ratings fuse sizes and size of controls connected to the PV output 2 GENERAL HANDLING AND INSTALLATION PN PV modules generate electricity when exposed to a light source Lethal shock and burn hazard can result from the contact of module live parts or wiring These hazards are increased with the multiple connections of PV modules to increase the system voltage or current The front surface of the module must be covered completely with an opaque material during installation maintenance or other ways of handling to avoid these hazards Do not connect or disconnect the cable coupler under load this can cause an electrical arc Shut down the string before start working on the modules YN Pv modules installation i
3. SEE ILB Helios AG ILB International Logistikbetriebe AG Bruggerstrasse 71 CH 5401 Baden Phone 41 56 205 30 60 Fax 41 56 210 02 28 2 14 www ilb helios group ch Copyright 2009 ILB Helios AG Specifications are subject to change without prior note ILB Helios is not responsible for spelling mistakes or missing parts ILB Helios AG Switzerland ILB Helios Spain S A ILB Helios Italia S r l NA Series Stand 25 02 2011 1 HELIOS GROUP du This guide provides basic information regarding the installation and handling precautions of ILB HELIOS photovoltaic modules PHOTOVOLTAIC NA Series 1 GENERAL INFORMATION Please read this guide entirely before the installation handling operation or maintenance of a PV module All instructions should be read and understood prior to performing the mentioned works ILB HELIOS is not responsible for damages caused by not following the instructions in the manual Please consult also the manual from the other companies supplier who are involved in the whole installation sit The installation manual is part of the documents bounded to the solar system and has to be stored together with the other documents related to this installation over the whole lifecycle of the product Please overhand this document to the operating company Pleas call ILB HELIOS if you have any questions related to the module installation site tilt angel or the installation it selves
4. information about the cable and the cable coupler please consult the module data sheet The module wiring is designed for series interconnection between modules by connecting the positive connector of one module to the negative connector of the adjacent module Make sure that the array is disconnected during the installation of modules Do not connect or disconnect the cable coupler under load Keep cable lengths as short as possible to reduce voltage drop Secure the wiring of modules connection to the supporting frame and use fastening techniques to avoid loose wirings Do not squeeze pull or bend cables forcibly Avoid running wiring over sharp edges Use only modules of the same type for series or parallel connections For the Maximum series fuse please consult the module data for detailed information For the module wiring use only cable coupler of the same type Keep the contacts of the cable coupler all the time clean Don t connect dirty cable coupler To connect the solar modules with each other in the array use only cable which has the licensing for this kind of use Do not connect or disconnect the cable coupler under load Bear the polarity in mind while wiring the modules 5 Ea CE ILB Helios AG ILB International Logistikbetriebe AG Bruggerstrasse 71 CH 5401 Baden Phone 41 56 205 30 60 Fax 41 56 210 02 28 9 14 www ilb helios group ch Copyright 2009 ILB Helios AG Specification
5. 09 ILB Helios AG Specifications are subject to change without prior note ILB Helios is not responsible for spelling mistakes or missing parts ILB Helios AG Switzerland ILB Helios Spain S A ILB Helios Italia S r l NA Series Stand 25 02 2011 1 HELIOS GROUP PHOTOVOLTAIC P swen 1 seeme rons ICE T A Non integral Modules Panels must be install over a fire resistance roof covering rated for the application class of the Module Panel Modules should not be shaded by external objects at any time Avoid mounting the modules with the junction box at the lower edge Do not drill holes in to the frame of the module as this may cause severe damage Do not cut or bend the module nor do any kind of modification on the frame Assure that the mounting systems are capable of safely supporting ILB HELIOS PV modules and ensure that the modules are not subjected to excessive forces due to thermal expansions of the support frame or structure Do not install PV module where wind or snow loads exceed its specified limit Please consult the module data sheet for detailed information Do not install PV module where inflammable materials are used Do not install PV module at locations where they may be exposed to corrosive matters as chemical factory etc Clearance distance between the module frame and the support frame or structure is required to allow ambient air circulation around the back of the module Min
6. ILB Helios AG Switzerland ILB Helios Spain S A ILB Helios Italia S r NA Series Stand 25 02 2011 HELIOS GROUP PHOTOVOLTAIC NA Series INSTALLATION MANUAL FOR ILB HELIOS PHOTOVOLTAIC MODULES Copyright 2009 ILB Helios AG Specifications are subject to change without prior note ILB Helios is not responsible for spelling mistakes or missing parts SCE ILB Helios AG ILB International Logistikbetriebe AG Bruggerstrasse 71 CH 5401 Baden Phone 41 56 205 30 60 Fax 41 56 210 02 28 www ilb helios group ch 1 14 ILB Helios AG Switzerland ILB Helios Spain S A ILB Helios Italia S r l NA Series Stand 25 02 2011 15 HELIOS GROUP dm 2 PHOTOVOLTAIC NA Series Content 1 GENERAL INFORMATION esseesennnm Imm mnm 3 2 GENERAL HANDLING AND INSTALLATION eer 3 3 MODULE WIRING AND ELECTRICAL CONNECTIONS eene 5 a e d trennen 6 D Parallel COBDecllOlIusvsvesurtfesastveiviuvqa ave vsY te kPs quM rad EvspraYVa aupra dFs UPS PUN URP FU VPxKd T Cc ByPass DOUG ene eee en eee ene eee eee 209 299 9014099 8000009 ee T as OUN ee E E E E EE 8 4 MECHANICAL INSTALLATION eere 9 NB Ez NANCE 13 6 Electrical Ratings of the Modules eeseeseeeeeeeeeeneennenne 13 ki COMIC 2 14
7. Ratings of the Modules You will find the actual electrical ratings for modules of the NA series in the data sheets provided on the ILB HELIOS home page http www ilb helios group com downloads datenblaetter e php or in your purchasing contract ECE ILB Helios AG ILB International Logistikbetriebe AG Bruggerstrasse 71 CH 5401 Baden Phone 41 56 205 30 60 Fax 41 56 210 02 28 13 14 www ilb helios group ch Copyright 2009 ILB Helios AG Specifications are subject to change without prior note ILB Helios is not responsible for spelling mistakes or missing parts ILB Helios AG Switzerland ILB Helios Spain S A ILB Helios Italia S r l NA Series Stand 25 02 2011 1 HELIOS GROUP d PHOTOVOLTAIC p NA Series 7 Contacts ILB Helios AG Switzerland Chamerstrasse 175 CH 6300 Zug Fax 41 0 41 7400842 E Mail solar ilb helios com Internet www ilb helios group com ILB Helios Spain S A S A Alvarez de Baena 4 ES 28006 Madrid Phone 34 91590330 Fax 34 914114547 E Mail spain ilb helios com Internet www ilb helios group com ILB Helios Italia S r l Via Leonardo da Vinci 97 I 20090 Trezzano s Naviglio MI Phone 39 02 48464167 Fax 39 02 48420120 E Mail italy ilbhelios com Internet www ilb helios group com Copyright 2009 ILB Helios AG Specifications are subject to change without prior note ILB Helios is not responsible for spelling mistake
8. ax 41 56 210 02 28 9 14 www ilb helios group ch Copyright 2009 ILB Helios AG Specifications are subject to change without prior note ILB Helios is not responsible for spelling mistakes or missing parts ILB Helios AG Switzerland ILB Helios Spain S A ILB Helios Italia S r NA Series Stand 25 02 2011 15 HELIOS GROUP PHOTOVOLTAIC p NA Series PV module should be fastened to each of the four supports using the appropriate clamping technique as per Fig 5 The fastening could be done on the front side of the frame with the precaution of not touching the glass and not becoming a source of shadow for the PV cells The holding bolt should be at least type Metric M6 8 8 See Fig 6 Fig 6 PV module could also be attached and mounted using predrilled holes on the frame those holes will be performed by ILB HELIOS upon request The module will be then attached with bolts washers and nuts of at least type Metric M6 see Fig 7 8 amp 9 The mounting procedure should be approved by ILB HELIOS otherwise ILB HELIOS cannot give any guaranty for the module Fig 7 VW Bear in mind the thermal expansion of the modules while you are installing them and keep enough space 5mm between each module SCEE ILB Helios AG ILB International Logistikbetriebe AG Bruggerstrasse 71 CH 5401 Baden Phone 41 56 205 30 60 Fax 41 56 210 02 28 10 14 www ilb helios group ch Copyright 20
9. ght 2009 ILB Helios AG Specifications are subject to change without prior 2 C ILB Helios AG ILB International Logistikbetriebe AG Bruggerstrasse 71 CH 5401 Baden Phone 41 56 205 30 60 Fax 41 56 210 02 28 12 14 www ilb helios group ch note ILB Helios is not responsible for spelling mistakes or missing parts ILB Helios AG Switzerland ILB Helios Spain S A ILB Helios Italia S r NA Series Stand 25 02 2011 1 HELIOS GROUP d The objective of this paragraph is to clarify the minimum general operations that should be followed for a suitable maintenance of ILB HELIOS PV modules and installations PHOTOVOLTAIC E NA Series 9 MAINTENANCE ILB HELIOS will perform periodical preventive maintenance of the PV modules or installation upon customer s request ILB HELIOS PV modules are designed to require very little maintenance The most important inspections to perform are the following Clean the glass surface regularly with a clean and soft cloth using mild detergent and water power output may decline with the dirt Do not use chemicals and do not uninstall the PV module from the array Periodically inspect for tightness all the electrical and mechanical connections of the PV modules including grounding connections of the PV modules and mounting racks This inspection should be carried at least twice a year Loose connections will cause damage to the module or array 6 Electrical
10. imum distance should be of 5 cm Assure the fulfilment of prevailing safety regulations when installing modules and use prescribed safety equipment Do not carry out installations with strong winds rain snow humidity or any other type of adverse meteorological condition Do not unpack the module until it is ready for installation Do not step or stand on module frame or glass surface back surface neither during installation or handling do not allow any object to fall and do not place any weight over the module Do not drop the module on the floor and do not lay it upon uneven surfaces The materials in contact with the aluminium frame should be corrosion resistant as stainless steel galvanized steel and aluminium or plastic Check each module for damages before installation Don t install damaged modules Modules are not allowed to stay in tail water Do not lift the module on the junction box nor on the cable of the junction box ILB Helios AG ILB International Logistikbetriebe AG Bruggerstrasse 71 CH 5401 Baden Phone 41 56 205 30 60 Fax 41 56 210 02 28 www ilb helios group ch 11 14 Copyright 2009 ILB Helios AG Specifications are subject to change without prior note ILB Helios is not responsible for spelling mistakes or missing parts ILB Helios AG Switzerland ILB Helios Spain S A ILB Helios Italia S r NA Series Stand 25 02 2011 JHELIOS GROUP PHOTOVOLTAIC NA Series Copyri
11. ing parts ILB Helios AG Switzerland ILB Helios Spain S A ILB Helios Italia S r l NA Series Stand 25 02 2011 1 HELIOS GROUP Adm eZ PV modules should be positioned facing south in the northern latitudes and facing north in the southern latitudes PV modules should not be shaded by other objects The tilt angle should be at least 10 to assure the self cleaning feature of the Module Please consult ILB HELIOS for detailed information regarding the recommended tilt angle for your site PHOTOVOLTAIC p NA Series 4 MECHANICAL INSTALLATION PV modules must be securely attached to the mounting surface using support frames systems or the corresponding installation kits provided by ILB HELIOS Pleas read the installation manual for the installation kit and or consult your seller for further information ILB HELIOS can also provide the planning and the installation of PV modules ILB HELIOS PV module mounting shall be performed according to the following instructions The PV module should be supported and anchorage on rigid beams by at least four points the supports should be located on the rear of the photovoltaic module by the frame side Each support should have at least an area of 4 cm The four supports should be located symmetrical to the centre of the module See Fig 5 S ECE ILB Helios AG ILB International Logistikbetriebe AG Bruggerstrasse 71 CH 5401 Baden Phone 41 56 205 30 60 F
12. land ILB Helios Spain S A ILB Helios Italia S r l NA Series Stand 25 02 2011 1 HELIOS GROUP PHOTOVOLTAIC NA Series b Parallel connection For applications with high current consumption containing low voltage loads you can interconnect several modules or strings parallel Wiring and connectors may become overheated based on the higher current in the system so correct dimensioned of cross sectional wires and connectors approved for the systems short circuit current should be used Fig 2 Parallel Connection c By Pass Diode By pass diodes are required to protect each string of the module from the effect of shading ILB HELIOS PV modules are equipped with factory installed by pass diodes Please consult the module data sheet for detailed information about the rated currency and the reverse voltage Bypass Diode Blocking Diode Salar Module Fig 3 Blocking and bypass diode installation SEE ILB Helios AG ILB International Logistikbetriebe AG Bruggerstrasse 71 CH 5401 Baden Phone 41 56 205 30 60 Fax 41 56 210 02 28 7 14 www ilb helios group ch Copyright 2009 ILB Helios AG Specifications are subject to change without prior note ILB Helios is not responsible for spelling mistakes or missing parts ILB Helios AG Switzerland ILB Helios Spain S A ILB Helios Italia S r l NA Series Stand 25 02 2011 1 HELIOS GROUP m 2 PHOTOVOLTAIC E NA Series
13. mble the module or remove any attached components nor step on the PV modules Do not drag the PV modules during handling Do not damage the back sheet of the module during handling Do not attach anything to the back surface Bear in mind the maximum weight load of the module q v module data sheet ILB HELIOS is not responsible for any problems related to an installation which was not done by ILB HELIOS it selves and ILB Helios will not take over the responsibility for such an installation Please read very carful the installation instruction for the installation kit Keep children away from the installation site Warn from danger points of the installation site Unauthorized person are not allowed to enter the installation site ILB Helios AG ILB International Logistikbetriebe AG Bruggerstrasse 71 CH 5401 Baden Phone 41 56 205 30 60 Fax 41 56 210 02 28 www ilb helios group ch 4 14 Copyright 2009 ILB Helios AG Specifications are subject to change without prior note ILB Helios is not responsible for spelling mistakes or missing parts ILB Helios AG Switzerland ILB Helios Spain S A ILB Helios Italia S r NA Series Stand 25 02 2011 1 HELIOS GROUP dm 2 3 MODULE WIRING AND ELECTRICAL CONNECTIONS PHOTOVOLTAIC NA Series Each ILB HELIOS photovoltaic module has two 4mm flexible solar cables Each cable has cable coupler with a snap in locking system MN For specific technical
14. nvolves electricity and requires specialized skills and knowledge The installation should only be performed by qualified personnel familiarized with the appropriate safety procedures The national and international regulations for installing electrical components and safety regulations have to be followed Special safety regulations must be obey for installations on the rooftop to protect the installation team and people who are passing by 5 E CE s ILB Helios AG ILB International Logistikbetriebe AG Bruggerstrasse 71 CH 5401 Baden Phone 41 56 205 30 60 Fax 41 56 210 02 28 3 14 www ilb helios group ch Copyright 2009 ILB Helios AG Specifications are subject to change without prior note ILB Helios is not responsible for spelling mistakes or missing parts ILB Helios AG Switzerland ILB Helios Spain S A ILB Helios Italia S r l NA Series Stand 25 02 2011 15 HELIOS GROUP PHOTOVOLTAIC NA Series we AEN onem roast ECEE m 2 Do not touch live parts or terminal connections with bare hands Use insulated tools and the appropriate safety equipment and procedures that are approved for working on electrical installations Do not open the junction box Follow the national and international regulations for lightning protection Work under dry conditions only Do not concentrate light artificially on surface of the PV module to increase its electrical output Do not bend disasse
15. s are subject to change without prior note ILB Helios is not responsible for spelling mistakes or missing parts ILB Helios AG Switzerland ILB Helios Spain S A ILB Helios Italia S r l NA Series Stand 25 02 2011 1 HELIOS GROUP PHOTOVOLTAIC NA Series a Series connection For applications with high operating voltage several modules or strings of modules are connected in series it is recommended to protect each string by an external blocking diode as per Fig 3 There is a risk of arcing with high DC voltages so the use of properly insulated wiring and connectors approved for the maximum system open circuit voltage is recommended YN The maximum open circuit voltage of the system must not be higher than the maximum system voltage for the module 1000V The amount of modules you can interconnect in an array should be selected according the optimum working voltage of the inverter but must not exceed the maximum system voltage of 1000V FN All junction boxes in the array must have at least the licensing for IP65 or IP67 Fig 1 Serial Connection gt ECE ILB Helios AG ILB International Logistikbetriebe AG Bruggerstrasse 71 CH 5401 Baden Phone 41 56 205 30 60 Fax 41 56 210 02 28 6 14 www ilb helios group ch Copyright 2009 ILB Helios AG Specifications are subject to change without prior note ILB Helios is not responsible for spelling mistakes or missing parts ILB Helios AG Switzer
16. s or missing parts SCE ILB Helios AG ILB International Logistikbetriebe AG Bruggerstrasse 71 CH 5401 Baden Phone 41 56 205 30 60 Fax 41 56 210 02 28 14 14 www ilb helios group ch