        A251x Series 50W LV Boards User Manual
         Contents
1.    All adjacent channels can be paralleled  with the exception of Channel 3 and 4  The pictured configuration shows   e Channels 0 1 paralleled  e Channels 2 3 paralleled  e Channel 4 5 6 7 paralleled    With this configuration the SYx527 system detects 3 channels  0  2  4   the lower channel index is assigned to the  paralleled channels     UM2851   A251x Series 50W LV Boards User Manual 10    11    CAEN Q Electronic Instrumentation       Fig  2   Mod  A251x with paralleled channels    Once the Connection Keys are secured  it is possible to put the shield in place    Remember that  at this point  it is necessary to short circuit the paralleled channels output  these connections must  be made as close as possible to the connectors  for both positive and negative voltages    The same procedure is necessary for the Sense terminals     UM2851   A251x Series 50W LV Boards User Manual    CAEN Q Electronic Instrumentation    3  Safety and installation requirements    General safety information    This section contains the fundamental safety rules for the installation and operation of the board  Read  thoroughly this section before starting any procedure of installation or operation of the product     Injury Precautions    Review the following precautions to avoid injury and prevent damage to this product or any products  connected to it  To avoid potential hazards  use the product only as specified  Only qualified personnel  should perform service procedures    Avoid Electric Overl
2.  2  aa        E  m    LALLLLLLIL   WITIIIIIII       Type  FCI ICD26513E4GVOOLF D Sub SKT 26 POS 2 28mm Type  FCI ICD26S13E4GVOOLF D Sub SKT 26 POS 2 28mm  Function  Group Interlock  insulated   Group Status Function  Group Interlock  insulated   Group Status   insulated   Status  0   3  4   7   VAUX  DGND  insulated   Individual Interlock  GND   Individual Status   GND   VAUX  DGND  Interlock operation  A251x  One Group  channels 0  3 and 4  7  can be ENABLED in one of the following ways       Short circuit IT  with DGND and IT  with VAUX pins on service connector      Send signal 4 6V   SmA current between IT  and IT   A251xA  One Group  channels 0  3 and 4  7  can be ENABLED in one of the following ways     UM2851   A251x Series 50W LV Boards User Manual    CAEN Q Electronic Instrumentation        Short circuit IT  with DGND and IT  with VAUX pins on service connector      Send signal 4 6V     5mA current between IT  and IT    One channel can be ENABLED in one of the following ways       Short circuit IT  with VAUX pins on service connector        Send signal 4 6V     5mA current between IT  and DGND    Status operation   A251x      Contact closed between ST  and ST  when no FAIL is present on one Group channel  0  3 and 4  7       Contact open between ST  and ST  when FAIL is present on one Group channel  0  3 and 4  7    A251xA      Contact closed between ST  and ST  when no FAIL is present on one Group channel  0  3 and 4  7       Contact open between ST  and ST  when FA
3.  UNDERVOLTAGE condition     EXTTRIP  channel OFF due to external TRIP line signal       INTTRIP  channel OFF due to internal OVERCURRENT condition   EXT_DIS  channel disabled by board INTERLOCK protection   PWR FAIL  channel OFF due to a Power failure    OVV PROT  channel with connector over voltage detected    TEMP ERR  channel over  gt 85  C   under  lt 5  C temperature     PID  Proportional Integrative Derivative  Parameters    The channels implement a digital type controller  The user has the possibility to change the loop parameters  Kp  Ki  and Kd   These operations are not allowed by CAENGECO2020 Control Software  but they can be done only in  transparent mode  see SY4527 manual   By typing P from the main menu  it is possible to open the interface to  modify the PID coefficients of the channels  All changes of the coefficients are saved by typing S    N B  The PID coefficients can be modified when the channels are switched off  In case of change of the coefficients  with the channels on  a confirmation message asks authorization to turn off the channel and change the  coefficients     t EXTTRIP and INTTRIP parameters are expressed in Hexadecimal format    UM2851   A251x Series 50W LV Boards User Manual 14    CAEN Electronic Instrumentation    Tools for Discovery          CAEN SpA is acknowledged as the only company in the world providing a complete range of High Low Voltage Power  Supply systems and Front End Data Acquisition modules which meet IEEE Standards for Nucl
4.  of the board   s Internal Trip Bus lines   Bits  0 N 1  allow the channel to sense the trip status from the corresponding lines when set to one  in  the same way  bits  N 2N 1  allow the channel to propagate the trip status over the Trip Bus  bit N on  line O and so on  see SY4527 User s manual     TripExt  settable  Must be set in the 0 255 range  Bits  0 3  allow the channel to sense the trip status from the  corresponding lines when set to one  in the same way  bits  4 7  allow the channel to propagate the trip  status over the trip bus  bit 4 on line O and so on  see SY4527 User s manual        13 UM2851   A251x Series 50W LV Boards User Manual    CAEN Q Electronic Instrumentation    All parameters can be changed when the channel is off  When the channel is switched on  only a variation of VSET in  a range of   5  is allowed  for adjustment purposes     To ensure that two or more channels are turned on   off with delays programmed by user  these  channels must be assigned the same value of the ChToGroup parameter and the desired time must be  entered in the OnGrDel and OffGrDel parameters  0   no delay   The switching on and off are performed  by entering the ChToGroup parameter value in the field OnGroup   OffGroup   available as parameters  of the board      The following messages may be returned by the SYSTEM when monitoring the channel status     OFF  channel turned OFF    OVC  channel in OVERCURRENT condition   OVV  channel in OVERVOLTAGE condition   UNV  channel in
5.  optimized to any load     UM2851   A251x Series 50W LV Boards User Manual 4    CAEN Q Electronic Instrumentation    2  Technical Specifications    Channel Characteristic Table    Table 1   Channel characteristics of the A251x LV Boards    Output Voltage 1 5 V  connector output  5 15 V  connector output   Max  Output Current 15 A 5A   Over Under voltage thresholds 0 6 V settable for each channel 4 16 V settable for each channel  Hardware OVV Protection 7 50V 17 50V       5 UM2851   A251x Series 50W LV Boards User Manual    CAEN Q Electronic Instrumentation    Front Panel    Ezaa agga      CA  aa a NG NG NA NG NG NG GG Se    sr TIITII        UG AAAH  eee       AIII  STTIITIIIL  FTTTTITITL     IPARADA Wi    CO E    SERRE HER aa KGG GNG KU    ca    BGH 3784  10A SOW    n       Fig  1   Mod  A251x series front panel  8 pin  amp  db 37 version     UM2851   A251x Series 50W LV Boards User Manual    CAEN Q Electronic Instrumentation    External connections    Output connectors  A251x A251xA          Safety Loop    S    SeOEGQSCOEOCSESEGOESOSSESS      Ka    CH4    CHa    o    CHS  CHS    Sze    To short on    Comet    E EJ EENEI  E E EE    CHG CH6      r    B    MAEL LL LL LESEEESLRr E3L  e i  UA KAEN EE   LL LE 3    i       O OOQDOOQOQOOQO         CH7   F7  Cd y   Safety Loop  Type  DC8W8SAOOLF D Sub 8W8 Type  FCI DCPV37S300GT DB37  Function  Out Channels  0 3  4 7  Function  Out Channels  0 3  4 7   Service connector  A251xA        STATUS   4 7  Ng    INT 4  7  KA                2 
6. CAEN Electronic Instrumentation    Tools for Discovery    UM2851  A251x Series 50W LV Boards User Manual  Rev  1   26 June 2014       Purpose of this Manual    This document is the A251x Series 50W LV Boards User Manual  it contains information about the installation  the  configuration and the use of the boards     Change Document Record      Date   Revision   Changes    26 May 2014 O   Ys PRELIMINARY Release       26 June 2014 Updated parameters p 13    Symbols  abbreviated terms and notation    T B D     Reference Documents    Disclaimer    No part of this manual may be reproduced in any form or by any means  electronic  mechanical  recording  or  otherwise  without the prior written permission of CAEN SpA     CAEN will repair or replace any product within the guarantee period if the Guarantor declares that the product is  defective due to workmanship or materials and has not been caused by mishandling  negligence on behalf of the User   accident or any abnormal conditions or operations     CAEN declines all responsibility for damages or injuries caused by an improper use of the Modules due to negligence on  behalf of the User  It is strongly recommended to read thoroughly the CAEN User s Manual before any kind of  operation  CAEN reserves the right to change partially or entirely the contents of this Manual at any time and without  giving any notice     Disposal of the Product The product must never be dumped in the Municipal Waste  Please check your local regulations  fo
7. IL is present on one Group channel  0  3 and 4  7       Level high on ST  when no FAIL is present        Square wave  TTL grounded  on ST  when FAIL is present    UM2851   A251x Series 50W LV Boards User Manual 8    CAEN Q Electronic Instrumentation    Channels in parallel    The A251x boards are provided with six Connection Keys  four X keys and two Z keys   that allow to connect the  channels in parallel     The X key allows to parallel two channels  the Z key allows to parallel four channels     As two or four channels are paralleled  the system automatically recognizes the actual number of channels  two or    four paralleled channels are seen by the control software as one channel with double or quadruple output current  and power     In order to connect the channels in parallel  follow these steps     e Remove ONLY the screws as indicated  orange circles     Li  I     I     l                    I  i  H       e Remove carefully the shield  e Insert the Connection Keys between the channels to be paralleled    o Each connection key is provided with 2x3 pin male strips  two for X keys and four for Z keys        X key Z key    o The 2x3 strips must be plugged into the relevant sockets on A251x  named J20 J27  see figure     UM2851   A251x Series 50W LV Boards User Manual    CAEN Q Electronic Instrumentation    mar     8  Na    r       d  3 E d      CG Oe   M   WD  j  gt     i    P   a r BEN paii m  ah pi B m a RA Do ish z  ka a SR     or  SE    ta oooe  eo    ht  ra    we    
8. des    The A251x boards can be controlled  either locally or remotely  through the SYSTEM software interface   For details on SYx527 System operation  please refer to the User s Manual of this product  The following  sections contain a description of commands available for the board control and status monitoring     A WARNING    THE MOD  A251x BOARD REQUIRE  SYSTEM FIRMWARE VERSION 2 00 01 OR LATER       Output control and monitoring    The following board parameters are available       Descritpion    BdStatus  monitor  bit O  PowerFail  if 1  failure in the channels local power supply  bit 1  Firwmare Checksum Error  if 1  error in the board firmware checksum  bit 2  HVMax Calibration Error  if 1  the board HVMax parameter  if present  is not calibrated  bit 3  Temperature Calibration Error  if 1  the board temperature sensor  if present  is not calibrated  bit 4  Under Temperature  if 1  the board temperature sensor  if present  signals a board temperature x 5   C  bit 5  Over Temperature  if 1  the board temperature sensor  if present  signals a board temperature  gt  65   C  bits 6  31  Reserved    For each output channel  the following parameters are available          Parameter   Descritpion    PW  ON OFF  Power parameter shows the ON OFF channel status  when set to ON  the channel is switched on  if the  INTERLOCK is not active and if the channel is enabled either locally or remotely     Tripint  settable  2N bit word  Dec  0 242N 1  max 16 lines  where N is the number
9. ear and Particle Physics   Extensive Research and Development capabilities have allowed CAEN SpA to play an important  long term role in this field   Our activities have always been at the forefront of technology  thanks to years of intensive collaborations with the most  important Research Centres of the world  Our products appeal to a wide range of customers including engineers  scientists  and technical professionals who all trust them to help achieve their goals faster and more effectively              CAEN S p A  CAEN GmbH CAEN Technologies  Inc   Via Vetraia  11 Klingenstrafge 108 1140 Bay Street   Suite 2 C  55049 Viareggio D 42651 Solingen   Germany Staten Island  NY 10305  Italy Phone  49  0 212 254 4077 USA   Tel   39 0584 388 398 Fax  49  0 212 25 44079 Tel   1 718 981 0401   Fax  39 0584 388 959 Mobile  49  0 151 16 548 484 Fax  1 718 556 9185  info caen it info caen de com info caentechnologies com  www caen it www caen de com www caentechnologies com    CAEN Q  Electronic Instrumentation    Tools for Discovery    UM2851   A251x Series 50W LV Boards User Manual rev  1   26 June 2014  00102 13 A2518 MUTX    Copyright    CAEN SpA  All rights reserved  Information in this publication supersedes all earlier versions  Specifications subject to change without notice     
10. egrative Derivative  Parameters             cccccccccccsseccccceesececcueeecseceueccesaueeccsssueecessuuecesstsueeeeeseueeeeeseggesss 14    List of Figures    Fig  1     Mod  A251x series front panel  8 pin  amp  db 37 VErsiOn            ccessccccccccssseeccccccesesessecccceesaueseecceeeseuesececesesuuaesseeceeeeeaanseeeeeesaenseeess 6  Fig  2   Mod  A251x with paralleled channels             ccccssssccccessscccceeseccececseseceesaeseceeseeseeeessaeeceeseeeseeeeeeaeseceeseeeeceesueaseeesaeuecessseaesecessugeeeeees 11  List of Tables   Table 1   Channel characteristics of the A251x LV Boards             00020000 0 naaa 5    3 UM2851   A251x Series 50W LV Boards User Manual    CAEN Q Electronic Instrumentation    1  A251x Series Overview    The Mod  A251x series are single width  5 TE wide  boards housing 8 LV floating channels  compatible with the  CAEN Universal Multichannel Power Supply System  SY1527  SY2527  SY3527  SY4527  SY5527   The floating return  allows on load grounding reducing the noise level  the floating channels are insulated from each other and from  Ground up to  150 V     Each output channel is provided with individual remote sensing lines to compensate for the voltage drop over the  connection cables    The Maximum channel power is 50 W  connector output   Channels can be connected in parallel with modularity 2  or 4 to obtain higher output power  for 2 4 modularity Iset resolution is 100 mA and Imon resolution is 10 mA      The available versions are the 
11. following     Version  A2517 A2518 A2519  Output Voltage  1 5 V 3 8 V 5 15 V  Max  Output Current  15A 10 A 5A    The Output Voltage RAMP UP and RAMP DOWN Times may be selected independently for each channel in the 1    200 ms range  1 ms step      Safety features include     OVERVOLTAGE  if a channel monitored voltage goes above the programmed Overvoltage threshold value  OVVThr    it is signalled to be in  overvoltage  and is switched off     UNDERVOLTAGE  when the monitored voltage goes below the programmed undervoltage threshold  UNVThr   the  channel is switched off    OVERCURRENT  if a channel tries to draw a current larger than its programmed limit  it is signalled to be in   overcurrent  and is switched off     The output channels can be enabled according to the interlock logic  see Interlock operation     All versions are available either with 8 pin 0 15   pitch high current output connectors  A2518 and A2519 series are  provided also with db 37 output connectors     A global enable disable connector allows to disable the channels and it is also possible  via front panel logic signals   to enable individually each channel  only for db 37 versions      Channels are organized into groups  and the turning on off of the channels within one group can be delayed up to  900ms  User programmable  between each other     Channels feature a PID  proportional integrative derivative  digital controller  whose parameters are User  programmable  in this way  the control loop can be
12. oad    To avoid electric shock or fire hazard  do not power a load outside of its specified range    Avoid Electric Shock    To avoid injury or loss of life  do not connect or disconnect cables while they are connected to a voltage  source    Do Not Operate Without Covers    To avoid electric shock or fire hazard  do not operate this product with covers or panels removed    Do Not Operate in Wet Damp Conditions    To avoid electric shock  do not operate this product in wet or damp conditions    Do Not Operate in an Explosive Atmosphere    To avoid injury or fire hazard  do not operate this product in an explosive atmosphere    Do Not Operate With Suspected Failures    If you suspect this product to be damaged  have it inspected by qualified service personnel     Safety Terms and Symbols on the Product    These terms may appear on the product    DANGER indicates an injury hazard immediately accessible as you read the marking   WARNING indicates an injury hazard not immediately accessible as you read the marking   CAUTION indicates a hazard to property including the product    The following symbols may appear on the product     DANGER WARNING  High Voltage Refer to Manual  Installation    The A251x are single width boards  At power ON the SYSTEM  the processor will scan all the slots in the  crate to find out where the module is plugged and what kind of module it is        UM2851   A251x Series 50W LV Boards User Manual 12    CAEN Q Electronic Instrumentation    4  Operating mo
13. r disposal of electronics products     Made In Italy   We stress the fact that all the boards are made in Italy because in this globalized world  where getting  the lowest possible price for products sometimes translates into poor pay and working conditions for the people who  make them  at least you know that who made your board was reasonably paid and worked in a safe environment   this  obviously applies only to the boards marked  Made in Italy   we cannot attest to the manufacturing process of  third  party  boards      ce X    CAEN Q Electronic Instrumentation    Index  la  A251x ENE OV Cl VOW La BNG AA AA 4  2  Technical Specifications anan AABANG NAKAKAPA DONA ANG 5   Gin lala SK ays  GA gy a eal    0  AA AA AAP 5  AA    e eA a Ee eae eee er eee 6  External Connections GANANG AKA nen shea GALE BAKA 7  CUT UGE CONNECTOR a NAA AA AN AG 7  SER  CEO NN NONA ANAN NANA AA AA ANG 7  interlock operatio AA 7  U OD AA 8  A O GAAN 9  3  Safety and installation requirements          sesessesessssesescecescecessecessecessecesssoecesoecesoecesoesesseoecee 12  Generaksalely WON aO NAG AA E Eaa E Ei 12  EE Aaea E E E E A E T EA UA AA AA E 12  Safety Terms and Symbols on the PRODUCE  20am NGANGA NDN NAA a a iaa iaia 12  a e 9 eee ene ean er en Ae PE O E E EEE E A E E eee 12  4  Operating modes          s sessescssescssesosossosossesossosossesossesossesosossossescssesessescssesessesosossosossesossesoss 13  Outpat contol and Monitore seeoreaena entree aot E EENE 13  PID  Proportional Int
    