Home

User manual - Axiome Alpha SA

image

Contents

1. 38 9 1 Cleaning the Separation Surface 38 Chapler tO 2 dree EE 39 Chapter T1 PAS IS an eee less 40 Page 3 axc 474 user manual Chapter 1 Precautions and safety regulations The axc 474 has been designed in compliance with the European EC safety and electrical regulations for data processing devices and in compliance with the safety regulations for terminals in the office equipment environment This machine can be used in permanent operation in the ambient conditions of an office The following guidelines must be applied when installing and manipulating the reader e The reader is equipped with a power cable which must be connected to an earthed wall socket e When installing the machine make sure that the wall socket for the power supply is always within the user s reach e Do not connect or disconnect the cables during a thunderstorm axc 474 user manual Chapter 2 General information 2 1 General technical information Operating temperature e Relative operating humidity e Storage temperature e Relative storage humidity e Power supply e Power consumption under 24V DC 2 2 Electronic characteristics e Microprocessor e Flash memory e Main motor e Interface 10 to 35 C 50 95 F 20 to 80 without condensation 0 to 40 C 32 105 F 40 to 80 without condensation Input 115V 230V AC 50 60 Hz auto switch Output 24 V DC R
2. CODE inside this area Reading axes min 24mm from the reference edge Reference edge max 210 mm 207 46 mm AXIOME axc 474 user manual unn 2 54 mm mm The minimal spacing between two bar codes must be greater than 4 time the biggest white space inside both codes Maximum number of barcodes on one track Max number of barcode heads on the axc474b bb The axc474b bb can decode the following barcodes e 2ofbinterleaved e Codabar e EAN8 e EAN 13 e Code 39 e Code 128 e Code AXIOME e Code UPC A e Code UPC E The head resolution is 20 Barcodes 250 Character for one reading 100 Characters for one barcode 1 2 heads 0 15 mm Page 10 axc 474 user manual 2 9 HP decoder card 2 9 1 TB2 3 head The resolution of the TB2 3 head is 0 15 mm with a field depth between 0 and 1 mm from the glass If you read codes which are not very dense or show some homogeneity defects when you print the black bars you can improve the reading reliability in moving the head about 2 3 mm away from the document The width of the glass 0 5 mm enables to hide through integration the small printing mistakes without penalising the codes which are not perfectly perpendicular for example sticked labels You can read the code despite the printing mistakes D di The length of the lighting wave 660 mm red also allows the reading of the codes printed with the ink jet method and on thermal paper
3. 7 8 4 1 Optical switch test The method to test the optical switch is digitally The functions described further on correspond to the light switches as given below 1 input switch OSW 1 2 separation switch OSW 2 3 output switch OSW 3 4 reserve switch Please refer to Figure 3 page 18 for the positioning of the optical switches By pressing key 1 2 3 or 4 the digital status of the corresponding optical switch can be obtained open closed amp 474 HyperTerminal x amp 474 HyperT erminal Pl x Fichier Edition Affichage Appel Transfert Fichier Edition Affichage Appel Transfert arse ve afl ue oel als ala l 5 8 alal 1 input switch x 1 input switch 2 separation switch 2 separation switch 3 output switch 3 output switch amp reserve switch amp reserve switch 9 thickness switch 5 thickness switch Status 1 245 i Status 1 _ s s 01 09 21 connect ANSI 182 4 01 12 09 connect ANSI 1920 4 Page 32 8 4 2 Thickness switch test axc 474 user manual To test the thickness switch documents of around 1 10 mm in thickness should be used This is usually the case with 80g m2 paper The thickness of the document is measured and the result represented by the letters or D is displayed on the screen Thickness measured D too thick too fine amp 474 HyperTerminal Pm x Fichier Edition Affich
4. In bootstrap loader mode the reader does not switch off automatically Page 22 axc 474 user manual 7 2 Installing Firmload Amongst the accessories packed with the axc 474 is a CD containing the firmware as well as a pre configured Hyper Terminal file 474 ht with the 19200 N 8 1 communication parameters used to load the firmware into the OMR reader To install just copy the Firmload axc474 directory from the CD into a directory on your hard disk Axc474 El x 2 Fichier Edition Affichage Favoris Seet v Liens Adresse C WINDOWS Bureau xc474 O InstallDemo478 SourcesDemog7 tuu ht ao p Loader2 exe Max478 HEX BJ Poste de travail objet s s lectionn s AL Figure 5 7 3 Loading firmware When first installing the axc 474 the firmware the MAX interpreter and the default configuration parameters have to be loaded into the reader memory 7 3 1 Setting the reader in bootstrap loader mode Press the control button approx 5 secs until the LED turns orange and release The reader is now in bootstrap loader mode ready to receive controls In this mode the communication parameters are still 19200 N 8 1 If no erase or write controls are sent to the reader the contain of the flash memory remains unmodified and it is possible to leave this mode by pressing the control button on the panel for 3 seconds Th
5. e One axc474 reader e One primary output tray e One cable for the serial connection DB9 DB25 One external power supply One power cable One user manual One MAX programming manual CD axc474 containing the firmware and software Page 15 axc 474 user manual Chapter 4 Presentation of the axc 474 The optical mark reader axc 474 is an automatic device lts conception provides easy use and access to the documents and requires little maintenance Its high transportation speed and the unique feeding system make it a particularly secure and efficient device Its programming possibilities make it flexible user friendly and easy to integrate into any data system 4 1 Disposition of the main parts Command button Contr le LED The reference face edge assists guidance of the document Document insertion tray Removable head cover oa fF D The document separation block prevents a document from joining the previous one This separation block contains a little wheel allowing you to adjust the separation depending on the thickness of the document Secondary output tray Removable primary output tray Adjustable stop allowing adaptation of the primary output tray to all document formats Figure 1 Page 16 axc 474 user manual 4 2 Disposition of the plug connections 1 Power supply 2 Serial connection plug 25 poles type V24 Figure 2 Remark To unplug the power s
6. You can read the code despite its angle Page 11 axc 474 user manual 2 9 2 Decoders character indicating the type of code read always precedes the value of the barcode I Code 2 5 interleaved forward backward A Code Codabar forward backward C Code 128 forward backward E Code 39 forward backward G Code AXIOME forward backward TA Code UPCA forward backward TE Code UPCE forward backward TFF Code EAN 8 forward backward TE CodeEAN13 forward backward The Axiome decoder read up to 20 bar codes 250 characters following one another on a document 2 9 3 Syntax The barcode syntax transmitted through the reader is the following Zxxxxxlyyy YYYY Distance between the barcode and the bottom Edge Type of barcode read Remark The distance between the barcode and the bottom edge of the document being not very precise it cannot be converted into a unit of measure This value depends on the type and speed of the OMR reader but is representative of the order in which the codes are read Page 12 axc 474 user manual 2 9 4 Configuration for HP decoder The configuration is directly done with a Terminal program on the OMR reader running in test mode For the test mode please refer to the corresponding chapter This method allows to activate or inactivate some codes The discrimination of the diverse codes is automatic nevertheless to improve the decoding speed as well as
7. to compensate the ageing process 2 5 Dimensions and weight of the machine e Length without tray 357 mm e Length with tray open 575 mm e Width 220 mm e Max depth 215mm e Weight 6 7 kg Page 7 axc 474 user manual 2 6 Optical characteristics 2 6 1 Optical switch The cells for document detection are red light beams that the document must cut in order to be detected refer to Figure 3 page 18 e Document detection cells 3 cells 2 7 Barcode head The barcode reading device comprises a special reading head connected by fibre optics to its decoding card e Barcode decoder 1or2 Type of read codes Codabar Code 39 2 5 interlaced EAN 13 EAN 8 Code 128 Code UPC E Code UPC others on request e Type selection Automatic discrimination by the reader e Resolution of barcode head 0 15 mm Max no of barcodes per column 20 barcodes 250 charact for one read 100 charact per barcode Min space between two barcodes Larger than twice the widest white space of the barcodes Page 8 axc 474 user manual 2 8 Adjustment of the Barcode reading head e Open the head cover refer to To open the cover page 19 e Measure the distance between the reference margin and e Position the centre of the reading head at the centre of the Barcode line on your document Moving the OCR read head Page 9 2 8 1 Barcode on the axc474b bb max 140 mm Reodhg axes max 65mm from the reference
8. age Appel Transfert SENSOR 1 input switch 2 separation switch 3 output switch amp reserve switch 9 thickness switch Status 5 B 01 18 31 connect ANSI 7 33 axc 474 user manual 8 5 Solenoid test The electro magnet of the document feeding tray can be verified in the solenoid menu By pressing key 1 the solenoid is fed and should push the paper towards the separating wheel amp 474 HyperTerminal B x Fichier Edition Affichage Appel Transfert Solenoid 1 power ON 2 power OFF Status power OFF ad 01 20 55 connect ANSI 19200884 7 8 6 Read test Paper transport mechanism barcode OCR read heads can be verified in the Read menu amp 474 HyperTerminal Fichier Edition Affichage Appel Transfert 7 le 51351 ala fix RERD MODE 2 external 3 transport 4 01 24 00 connect ANSI 19200 8 N 1 D fil rz Page 34 axc 474 user manual 8 6 1 External mode For this test at least one barcode or OCR head should be present along with respective decoders The functioning and positioning of the barcode OCR head is verified in this mode The type of code and its value will be displayed on the screen In this mode the thickness detector is deactivated amp 474 HyperT erminal ml x Fichier Edition Affichage Appel Transfert 2 nel als ele External data mode ERRCA 74 E13789 ERACA 74 p 4 b 01 28 31 co
9. ansfert 7 Del ex 8 al 1 LED green x 2 LED red 3 LED orange key test EI Status KEY OFF gt 00 17 51 connect ANSI 192008N 1 D n Num 30 axc 474 user manual 8 3 1 LED test By pressing keys 1 2 or 3 the LED see position 2 of Figure 1 page 16 turns green red or orange respectively and status is displayed on the screen 474 HyperTerminal lol x Fichier Edition Affichage Appel Transfert olej al le ol 1 LED green E 2 LED red 3 LED orange key test Giutns s EB ON H atus green 00 47 06 connect ANSI 18200881 gt 8 3 2 Key test The status of the reader s control switch see position 1 of Figure 1 page 16 is displayed on the screen and indicates whether switch is pressed KEY ON or released KEY OFF amp 474 HyperTerminal OI x Fichier Edition Affichage Appel Transfert Del es ele 1 LED green a 2 LED red 3 LED orange key test Status KEY ON 00 51 34 connect ANSI 1920088 1 Ma Nu Z Page 31 axc 474 user manual 8 4 Sensor test Optical switch functionalities and thickness detector may be verified in sensor menu amp 474 HyperTerminal ini x Fichier Edition Affichage Appel Transfert SENSOR input switch separation switch output switch reserve switch Ami thickness switch e 00 55 23 connect ANSI 19200847 Mai Num
10. axc474B BB U ser manual English on January 2003 Copyright c BY AXIOME ALPHA 16 06 03 all rights reserved Unauthorised use duplication or distribution is prohibited Because we are constantly improving our products Axiome Alpha SA reserves the right to modify technical features without warning axc 474 user manual Chapter 1 Precautions and safety 4 Chapter 2 General information 5 2 1 General ene le Men e 5 2 2 Electronic characteristics suat nt ah nt is 5 2 3 Mechanical characteristics Al AA te nee Atay 6 2 4 MTBF6 2 4 1 Feeding 6 2 4 2 Transport 6 2 4 3 Electronic 7 2 5 Dimensions and weight of the machine ss 7 2 5 Optical Ee 8 2 6 1 Optical switch 8 2 Barcode hedd EE 8 2 8 Barcode on Ine axes 74b DD i e d e oe e cem o ice 10 29 PP IdeCcOder CANO o ke dete o tested eta snc eet 11 2 9 1 TB2 3 head 11 2 9 2 Decoders 12 2 9 3 Syntax 12 2 9 4 Configuration for HP decoder 13 2 10 Olga iere 14 Chapters Installation siie usant nuls nt is n 15 3 1 Choice of DOSIHOIT unes A cid edat ees 15 3 2 List of the contents of the package c aee sto e ae i t cetus 15 Chapter 4 Presentation of the axc 474 16 4 1 Disposition of the main parts ss 16 4 2 Disposition of the plug connections ss 17 4 3 Disposition OL the ee EE 17 Chapter 5 Openin
11. e LED goes out and as soon as the button is released the power cut off Page 23 axc 474 user manual Remarks The bootstrap and the loader are located in a protected block of the flash memory Due to this fact they cannot be modified or destroyed by human error or by an accidental shutdown However the application program may be deleted or partially destroyed by LOADER misuse In this last case the reader will be unusable and the loading process must be restarted The bootstrap may not automatically detect a corrupt application Especially when an invalid program is loaded on top of a previous valid program There is no power off timeout in the bootstrap loader sequence 7 3 2 Download firmware 1 Runthe Loader2 exe file located under directory Firmload axc474 The default communication port is COM1 If you wish to change it select Connect the cable place the reader in BootStrap mode Loader II 1 0 load firmware utility for flash machines Select Pot C Com2 Com 3 Fee Remark if communication is established the reader will respond by giving its name and its release version 2 Click Load and select the firmware hex file to download During the transfer process the LED of the control panel flashes orange The download of the firmware hex file takes approximately 50 seconds Loader 11 1 0 load firmware utility for flash machines gt Select Pot C Com Ce Com Co
12. e list only provides status of peripherals and does not allow correction of errors To set up peripherals please use the SET UP menu see chapter 8 7 Reader set up page 35 474 HyperTerminal al x Fichier Edition Affichage Appel Transfert 7 Dis alz del e Search motor driver Search sensor driver Search Externall Search External2 00 ERROR detected e 4 00 02 05 connect 19200 amp N 1 D fi Mai 7 29 axc 474 user manual 8 1 1 Configuration error detected In case of an error the list indicates the type and number of the detected error 8 2 Motor test The forward backward function of the document transport motor can be verified using motor test amp 474 HyperT erminal DI x Fichier Edition Affichage Appel Transfert 2 MOTOR 1 forward 2 stop 3 backward_ E 4 b 00 13 05 connect ANSI 19200 8 N 1 Ma 2 8 2 1 Motor forward When the 1 key is pressed the motor runs in forward mode and the status is displayed on the screen amp 474 HyperTerminal O1 Fichier Edition Affichage Appel Transfert 7 Di 85 2al 1 forward 2 stop 3 backward Status motor forward po m 00 15 07 connect ANSI 19200 8 N 1 Defi Ma 2 8 3 Panel test The LED color function and the control switch can be verified in front panel menu amp 474 HyperTerminal m x Fichier Edition Affichage Appel Tr
13. es Disable e Disable i Disable t Disable a Disable c Disable f CODE 39 check digit Int 2 5 check digit Enable 1 Code 11 check digit 01 57 03 connect D tection auto 192008N 1 D Ma Num Capturer Echo Remarks Attention these functions are case sensitive Page 13 axc 474 user manual 2 10 Programming Software AXIOME has developed a series of programs enabling optimal use of the readers The conception of the program series provides several levels of performance and flexibility and provides at each level an extension of the inferior levels Each reader is delivered with the basic standard interpreter software MAX and a default configuration file Page 14 axc 474 user manual Chapter 3 Installation 3 1 Choice of position e Place the reader on a stable flat and horizontal supporting surface e Protect the reader from any source of heat such as direct sunlight heating radiator etc e Also protect the machine from vibrations and humidity e Never use the axc 474 in rooms where the atmosphere is contaminated by dust or oil in the gaseous state 3 2 List of the contents of the package Check that the elements mentioned on the list below correspond to the contents of your package If the equipment has been damaged during transport or some elements are missing contact your dealer or Axiome Alpha SA Switzerland see address at the end of the manual List of contents
14. g EE 19 5 1 open the EE 19 Chapter 6 Connections of the axvcA 3 s sssssnsssennseneernneeenrerrnnerrnnrennernnrrnenen 20 6 1 Connecting Be E 20 6 2 Disconnecting the Sade E 20 6 3 Standard RS232 interface connecting diagram sss 20 6 4 5232 connection cable E 21 Chapter 7 Using the reader for the first time reenen 22 7 1 Control switch EBD seeded Ee ee EE 22 7 1 1 Starting in read mode 22 7 1 2 Starting in test mode 22 7 1 3 Starting in bootstrap loader mode 22 7 1 4 Switching off 22 7 2 Installing 23 7 3 Loading firmware e ccs eme reete qo pe eee eer ee ne 23 axc 474 user manual 7 3 1 Setting the reader in bootstrap loader mode 23 7 3 2 Download firmware 24 7 4 Insertion of QOCHITIGITIS 6 cite oon ne atten ek len a enn nn nn 25 7 5 Adjusting the document separation 26 NET e Test le Le EE 27 ast eil e UE lee HU EE 29 8 1 1 Configuration error detected 30 62 MOIOT LOS acess dices cesar EE 30 8 2 1 Motor forward 30 E EE 30 8 3 1 LED test 31 8 3 2 Key test 31 EE Rd ne tete c dr MN ele nest nt en 32 8 4 1 Optical switch test 32 8 4 2 Thickness switch test 33 ee br 34 8 6 Read KE Re NRA RAT to 34 8 6 1 External mode 35 8 6 2 Transport mode 35 Br e ET A Ne ir tn 35 8 7 1 Initialise Ext1 36 8 7 2 Disable Ext 37 8 7 3 Initialize Ext2 37 8 7 4 Disable Ext2 37 8 7 5 User parameter 37 Chapter 9 Preventive maintenance
15. hapter 7 Using the reader for the first time 7 1 Control switch amp LED The control switch presents 4 distinct functions with corresponding LED coloring 7 1 1 Starting in read mode Press the control switch until the LED turns green then release An auto test is carried out If it is unsuccessful the LED flashes red green If the problem persists switch to test mode see below If the auto test was successful the reader is now in read mode and is ready to be piloted by the communication software 7 1 2 Starting in test mode Press the control switch until the LED turns red approx 2 5 secs then release The reader is now in test mode ready for various functional tests on the machine For further information regarding this mode please refer to Chapter 7 4 Insertion of documents page 25 7 1 3 Starting in bootstrap loader mode Press the control switch until the LED turns orange approx 5 secs then release The reader is now in bootstrap loader mode ready for loading of new firmware For further information on this mode please refer to Chapter 7 3 Loading firmware page 23 7 1 4 Switching off Whatever mode the reader is in press the control switch until the LED turns off approx 3 secs then release In read mode the reader switches off automatically after 5 minutes on standby no command sent to the reader and no button pressed In test mode the reader switches off automatically after 1 hour on standby
16. it e Put back the separation block Figure 8 Page 38 axc 474 user manual Chapter 10 Error list Below is a list of errors that may be returned by the reader in reading mode No 000 001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016 017 018 019 020 021 022 023 024 025 026 027 028 Description DATA BUFFER EMPTY BAD FEEDING JAM BEFORE HEAD JAM UNDER HEAD JAM AFTER HEAD JAM IN SORTING NO SHEET ON LIFT SHEET TOO SHORT SHEET TOO THIN SHEET TOO THICK SHEET TOO LONG INCORRECT SHEET NO SHEET TO SORT PATH NOT FREE HEAD INIT ERROR NO DECODER FAILED Ch x Page 39 axc 474 user manual Chapter 11 Parts list The replacement parts for the axc 474 can be ordered from AXIOME Alpha SA or from your retailer Description Part number Units per machine EALI024 power supply 24V 50W connector mini din 12mm axc 474 EFUE034 Fuse 2 AT FST for 230V EFUE037 Fuse 4 AT FST for 115V EMAG125 solenoid stc 1253 dc 12v FCOC132 Mini pitch belt 80 132 x 1 4 FORE139 O ring 55 25 x 2 62 FORE148 O ring 69 52 x 2 62 M985504 Transport wheel M985506 Separation Wheel P sch LL LB Lm Lo oL on SBARHP1 barcode decoder hp 1or2 SBATF950 Barcode head TB2 3 1or2 S474801 board CPU474 2 1 S478804 thickness controler S478813 light switch board axc 474 S950803 Control panel axc 474 axm 950 UOU Page 40 E AXIOIII AXIOME ALPHA SA 1 rue du Chasselas CH 2034 Peseux Switze
17. le t or Enable T UPC ERN Disable a or Enable R Codabar Disable c or Enable C CODE 128 Disoble f or Enable F CODE 11 Disable g or Enable G MSI code Disable m or Enable M CODE 39 check dioit Disable n or EnablelN Int 2 5 check digit Enable 1 or Enable 2 Code 11 check digit EELER CLEES Attention these functions are case sensitive Page 36 axc 474 user manual 8 7 2 Disable Ext1 In this menu the decoder connected to external interface 1 can be disabled This becomes effective immediately after leaving the menu 8 7 3 Initialize Ext2 In this menu the decoder connected to external interface 2 can be activated and configured Please refer to chapter 8 7 1 Initialise Ext1 page 36 for the settings 8 7 4 Disable Ext2 In this menu the decoder connected to external interface 2 can be disabled This becomes effective immediately after leaving the menu 8 7 5 User parameter To be used to visualize and erase data contained in the flash memory block 1 Erasing user parameters leaves the reader with default parameters Especially the baud rate setting of the reader is set back to 19200 N 8 1 Page 37 axc 474 user manual Chapter 9 Preventive maintenance 9 1 Cleaning the Separation Surface e Take off the document separation block by pulling first horizontally 1 the grooved screw and after up 2 see figure below e Clean the separation pad rubber using a cloth moistened with methyl spir
18. ll switch on the axc 474 and its peripherals On the axc 474 the connection plugs are located at the bottom of the machine refer to chapter 4 2 Disposition of the plug connections page 17 6 2 Disconnecting the reader Never try to disconnect a cable by pulling on the electrical lead Instead pull on the mechanical part of the plug e Remove the power cable e Disconnect the external power cable e Disconnect the data transfer cable 6 3 Standard RS232 interface connecting diagram f 2 0 0 0e A 2 CEKIT 25 14 2 lt gt 3 lt gt RXD 4 lt RTS 5 CTS 7 lt gt GND 20 DTR Page 20 axc 474 user manual 6 4 RS232 connection cable The following diagram corresponds to the RS232 V24 serial connection between a PC and a reader null modem One cable of this type is delivered with the machine However such cables are also to be found at local dealer s under the designation DB9 Female DB25 male PC Reader 9 Pin 25 Pin pcp 1 44 Rrs Rxp 2 412 rxo Txbp 8 s Jaxp 5 Tr CTS eloen GND 5 Z DSR 6 RTS 8 8 20 DTR The equivalent DB25 female male cable can also be obtained in the commerce PC Reader 25 Pin 25 Pin Prot GND 9 24 Pret GND TXD TXD 21 axc 474 user manual C
19. m3 Remark As soon as the download is finished the reader is switched off Page 24 axc 474 user manual 7 4 Insertion of documents The output tray must be adjusted to the format of the document The documents must be placed in the input tray with the barcode marks on the front Place the pile of documents on the reference s side and push it in the direction shown by the arrow Don t go beyond the fold in the sheet metal behind the documents In proceeding the same way it is possible to insert only one document Insertion of documents Figure 6 Page 25 axc 474 user manual 7 5 Adjusting the document separation In the most cases it is not necessary to adjust the document separation however if the reader send a bad feeding or double feeding message you must readjust it To do so follow the procedure below e Active the reading process using an application program or select the read test mode refer to chapter 8 6 2 Transport mode page 35 e Puta document stack in the input tray e Adjust the grooved screw until documents are fed through without being stopped by the separation block If two documents are simultaneously transported the grooved screw must be turned in the arrow direction Figure 7 Page 26 axc 474 user manual In test mode it is possible to verify and set up configuration of various reader functionalities However a serial connection with a computer and a HyperTerminal type co
20. mmunication program or equivalent is indispensable The communication parameters must be configured at 19200 N 8 1 To do this please follow the procedure below 1 Run Hyper Terminal select FILE then PROPRIETES 474 HyperT erminal Propri t s 2 Select the communication port to which the reader is connected Propri t s de 474 beem hs _ EL Diriger vers Com2 E Diriger vers Com3 v Unsedecode dupa Pare capea M si occupe Page 27 axc 474 user manual 3 Configure the communication parameter to 19200 N 8 1 Propri t s 1 ppIquEre When the reader is switched to test mode red LED the following menu is automatically displayed on the PC monitor screen If the reader is already in test mode press escape on the computer keyboard to display the menu 474 HyperTerminal ols ola zl e Board Axm Axc 200 0050 TEST release 1 14 API rel 1 00 Appl 150 1 Configuration list 5 Solenoid 6 Read Page 28 axc 474 user manual On the main menu the following indications are found CPU Version Axm Axc xxx e API Version API release x xx e Firmware Version Appl MAX xxx Remark To go to the next menu of your choice press the corresponding key To return to the previous menu press the ESC button on your keyboard 8 1 Configuration list This list gives the reader configuration indicating which elements are present or absent Th
21. nnect ANSI 19200 8 N 1 D fil z 8 6 2 Transport mode With the transport test the transport function can be verified by ejecting 1 document out of 4 into the secondary tray In this mode all read heads barcode OCR are disabled but the thickness detector remains enabled 8 7 Reader set up The reader set up menu allows configuration of peripherals barcode and or OCR amp 474 HyperTerminal iof x Fichier Edition Affichage Appel Transfert 7 3 Initialise Ext1 amp Disable Ext1 9 Initialise Ext2 6 Disable Ext2 9 User Parameter 01 31 51 connect ANS 19200 8 N 1 Maj Num 7 2 35 8 7 1 Initialise Ext1 This menu allows activation and configuration of the decoder connected to external interface 1 axc 474 user manual With a barcode decoder this menu allows to select the different types of barcode to be read Code 39 Ivesl nol ves 1011 321 nt 2 5 ves Ino UPC EAN iyves ves Codabar Ives no Code 1281lvesll ves ICode 11 Jino 111 IHSI CodelInol yes yes 061 3211 yes fixed no IE 3211 no 11 3211 1017 O21 111 3211 IE 1 1 IAJ cl If 1 tvariable length l Ilstart stop transmitted l To change the displayed configuration press ENTER then activate or deactivate the types of barcode as desired by pressing the respective keys see below Remarks LETTERE Disable i or EnabletI Int 2 5 Disab
22. rland Tel 441 0 32 732 18 18 Fax 441 0 32 732 18 00 Web site http www axiome ch e mail info axiome ch axc 474 user manual Identification et saisie de donn es Identification and data capture Basel Zurich PeSeUX Gi Geneva Ref LI47USE100 Page 41
23. the reliability we advise you to activate only the decoders of the used barcodes Test 950 HyperTerminal lof x Fichier Edition Affichage Appel Transfert n ol sole sl CONFIGURATION DISPLAY SCREEN version 12 4 c Hewlett Packard 1986 CODE READ CHECK CHAR LENGTH CODE ID OTHER CONFIG SETTINGS verif xmit min max xmit onl Code 39 yesl Inol ves 1 32 Int 2 5 yes no ves 141 32 UPC ERN yes ves ves Ewe Codabar yes no no variable length start stop transmitted Code 128 yes ves Code 11 nol 11 e ETS yes Settings now in use press ENTER to change settings 01 55 38 connect D tection auto 192008N 1 Maj Num Capturer Echo To change the displayed configuration press ENTER then activate or deactivate the types of barcode as desired by pressing the respective keys see below Test axm950 HyperT erminal OI x Fichier Edition Affichage Appel Transfert 2 CONFIGURATION DISPLAY SCREEN version 12 4 c Hewlett Packard 1986 CODE READ CHECK CHAR LENGTH CODE ID OTHER CONFIG SETTINGS __ verif_xmit_ min__max xmit on Code 39 yes no ves 1 321 E Int 2 5 yes no yes 141 32 variable length UPC ERN yes ves Codabar yes no start stop transmitted 128 yesl ves ICode 11 nol 11 We Ge wie y
24. unning mode 1 6 Amax Standby 2 4 mA 188 5 256 bytes divided into 5 blocks Block 1 16 Kbytes boot Block 2 8 Kbytes user parameters Block 3 8 Kbytes set up parameters Block 4 96 Kbytes calibration parameters Block 5 128 Kbytes firmware Stepping motor Serial V24 RS232C Page 5 2 3 Mechanical characteristics e Feeding Capacity of the input tray Capacity of the output trays e Document transport speed Weight of paper e Minimum document format e Maximum document format e Paper quality e Document alignment e Tray management 2 4 MTBF 2 4 1 Feeding e First transport wheel Separation wheel axc 474 user manual Automatic 100 documents for documents of 90 gr m Refused 100 documents Accepted 100 documents for documents of 90 gr m 0 5 m s 80 to 160 g m 113 x 38 mm 4 4 x 1 5 210 x 140 mm 8 26 x 5 5 Optical reading quality non chemical Automatic Controlled by the program 1 000 000 documents 1 000 000 documents average depending on paper quality 2 4 2 Transport e Transport wheel e Mini pitch belt e O ring belt e Step motor 5 000 000 documents 20 000 000 documents 5 000 000 documents 100 000 hours average depending on paper quality Page 6 axc 474 user manual 2 4 3 Electronic e Electronic boards 50 000 hours e Light barrier Automatic adjustment
25. upply cable pull the connector and not the cable 4 3 Disposition of the optical switch The axc 474 contains three optical switch allowing e Control of the document transport e Detection of the paper e Detection of the secondary output tray Each optical switch is defined as follows see position on Figure 3 OS1 Controls if there are documents in the input tray for automatic feeding 052 Detects a document before it passes under the read head OS3 Controls the document transport and detects if the secondary output tray is full Page 17 axc 474 user manual Disposition of the optical switches on the reader Figure 3 Page 18 axc 474 user manual Chapter 5 Opening 5 1 To open the cover It is necessary to open the cover that gives access to the barcode or OCR read head if you will adjust there position To open the cover 1 remove the separation block 2 unscrew the cross screw placed behind the separation block 3 pull as indicated by the arrow Figure 4 Page 19 axc 474 user manual Chapter 6 Connections of the axc 474 6 1 Connecting the axc 474 When installing the axc 474 and its peripherals the cables must be connected in the following order e Connect the cable for serial data transfer to the reader s first then to the PC e Connect the external power supply cables first to the reader then to an earthen wall socket e Once these steps have been taken a pressure on the control switch wi

Download Pdf Manuals

image

Related Search

Related Contents

ビジック 3シリーズ新登場  "取扱説明書"  Instrucciones de servicio - Industry Support Siemens  Curtis CR1353 User's Manual  UMC5200AA Electric Microwave  福岡拘置所の平成13(不存在)に関する件  User Manual  INSTRUCTION AND INSTALLATION MANUAL  info  BENDIX BW1580 User's Manual  