Elektron C6 owners manual rev 3

image

Contents

1. as MIDI SDS as a MIDI SDS transfer is always mono L R sends a mix of the two channels Left or Right sends the selected channel only GLOBAL e Sample position Enter the sample position you want the MIDI SDS file to contain when sending an audio file Automatically updated for each sent file to allow for easy transfer of multiple files STATUS ROW e Progress bar Shows the progress of each sent file e Sending text Displays Sending when sending is in progress e Receiving text Displays the number of received data bytes C6 Sysex Tool User s Manual 4 FUNCTIONS OF THE CONFIGURE WINDOW FUNCTIONS OF THE CONFIGURE WINDOW MIDI Preferences MIDI In XP MIDI mate XP MIDI mate Cancel Reload files Delay ticks Midi Out Interface 0 XP MIDI mate XP MIDI mate e Ok Accept and save changes e Cancel Exit window without saving changes e Reload Files When this option is chosen C6 will reload the files open in the data browser when the program is started next time e Delay C6 XP Time in milliseconds between each package when sending MIDI out Increase this number if you have problems with transfers not mak ing it over to the other side Typical amounts should be in the 5 to 50 region C6 OS X Time in ticks between packages when sending an audio file as a MIDI SDS dump A tick is around 1 60 second Increase this number if you have problems with transfers not making it over to the other side Typical
2. C6 Sysex Tool User s Manual Copyright 2005 ELEKTRON MUSIC MACHINES AB Rev 3 C6 XP 0 996 and C6 OS X 0 96 INTRODUCTION C6 is a sysex tool developed by Elektron Music Machines for use with its product line the SidStation the Machinedrum and the Monomachine C6 is particularly useful for transferring samples to and from the Machine drum SPS 1 UW Supported formats are MIDI System Exclusive Sysex files Additionally mono or stereo wave and aiff audio files are supported for transfer using the MIDI Sample Dump Standard SDS protocol MIDI SDS is a subset of the MIDI Sysex standard Data received via MIDI can be saved as MIDI Sysex Please use your favourite audio editor for preparing the samples prior to transfer as C6 is not an audio editor or player Since C6 displays information on the contents of received Sysex Dumps for Elektron products C6 is useful for doing Sysex backups C6 is most likely suitable for use with other products as well SYSTEM REQUIREMENTS SYSTEM REQUIREMENTS A MIDI interface C6 XP An x86 compatible computer running Windows The software has been tested on Windows XP but should work on 98 ME 2000 C6 OS X The software has been tested to work on version 10 4 or higher but should work on 10 3 and could work on 10 2 SETTING UP THE SOFTWARE e Start C6 e Click on Conf and select the MIDI In port and MIDI Out port from the two lists e Press OK LICENCE amp DISCLAIMER This
3. amounts would be 1 or 2 MIDI IN Lists available MIDI ports ready for selection MIDI OUT Lists available MIDI ports ready for selection C6 Sysex Tool User s Manual 5 THE FILELIST FILE FORMAT C6 THE FILELIST FILE FORMAT C6 This is c6 own file format that saves the list of the files currently loaded as well as their loop and stereo settings If the c6 file is put in a parent directory of a file in the list that file path will be stored relative to the directory This can be useful for example if you want to archive or move a project C6 XP The c6 file can be saved either by not selecting any file in the filelist or by specifying the c6 extension in the save file selector C6 OS X The C6 file is the selected file format when choosing save file and no files in the filelist are selected C6 Sysex Tool User s Manual 6
4. nd the current selection of files During transmission the button changes to Stop Stop stops the current transfer Pressing Send with no file selected opens the Load dialog e Receive Receive a sysex to C6 During reception the button changes to Stop When all data is received use Stop to finish the current receive If some data has been successfully received you will see a new entry in the list browser e Load Load files to send from C6 e Save Save the current selection of files or received data to disk e Close Remove the current selection of items from the data browser e Config Configure C6 to you own taste e Exit Quit C6 C6 Sysex Tool User s Manual 3 FUNCTIONS OF THE MAIN PROGRAM WINDOW DATA BROWSER Lists all loaded files and the received data Filename length and type is listed Select an item to get additional info in the File Info field The items in the data browser can be rearranged Drag and drop to the data browser is supported FILE INFO Shows additional info about files and received data For Elektron sysex dumps a brief description of the contents is displayed For audio files the basic parameters are listed e Loop For audio files the looping behaviour is controlled when sending them as a MIDI SDS Loop File honours the looping infor mation stored in the file Loop On forces looping behaviour Loop Off selects no looping e Stereo Selection for stereo audio files what to send
5. software is freeware The software is provided as is without warranty of any kind express or implied including but not limited to the warranties of merchantability fitness for a particular purpose and noninfringement In no event shall the authors or copyright holders be liable for any claim damages or other liability whether in an action of contract tort or otherwise arising from out of or in connection with the software or the use or other dealings in the software C6 Sysex Tool User s Manual 2 FUNCTIONS OF THE MAIN PROGRAM WINDOW FUNCTIONS OF THE MAIN PROGRAM WINDOW OS X eA C6 Sysex Tool by Elektron v0 96 Send Receive Load Save Close Config Exit File Size Type Users nemobackspin Desktop dumpy syx 1661187 Users nemobackspin Desk ktron_SPS1_1UW_OS1 30 syx 1608966 MD Users nemobackspin Desk MK2_KIT Linn cowbell WAV 8908 Users nemobackspin Desktop MMOs1_05b__ syx 870798 MM Users nemobackspin Desktop turbo_force syx 9 File Info Global Sample length 4400 Channels 1 Sample Rate 44100 z Bits 16 Loop OFF _Loop File Sample Position 0 XP ot Sysex Tool by Elektron v0 99 Boe Filename Size Type C Documents and Settings anders Desktop turbo_on syx 8 H public md_kraftwerk syx 3762 MD File Info Global Normal Globals 8 Kits 128 Patterns 128 Songs 32 Samplepos Broken Globals 0 Kits 0 Patterns 0 Songs 0 e Send Se