Home

Sears 200.71495 User's Manual

image

Contents

1. and 80 F Do not use the inverter near an open engine compartment Only connect the power inverter to a 12 volt battery accessory outlet or 12 volt battery Make sure the AC plug and or USB connection is tight Do not modify the AC or USB receptacle in any way Use only 40 amp or 50 amp fuses Replaced by certified technician only 1 800 SEARS 64 WARNING Handling the cord on this product or cords associated with accessories sold with this product may expose you to lead a chemical known to the State of California to cause cancer and birth defects or other reproductive harm Wash hands after handling 2 POWER INVERTER 750 PRODUCT FEATURES 1 ON OFF Button 2 Digital Display 3 LED Indicators Voltage In Voltage Out Power Out 4 Two 3 prong 110V AC Outlets 5 Positive and Negative Connector Knobs not shown 6 USP Port not shown Battery Clamps 12V Accessory Plug 3 BEFORE USING POWER INVERTER 750 It is important to know the continuous wattage of the device you plan to use with the inverter The Power Inverter 750 must be used with devices drawing 750 watts or less If the wattage is not marked on the device an estimate can be made by multiplying the AC input current Amps by the AC voltage 110V Devices like TVs fans and electric motors require additional power to start commonly known as the starting or peak power The Power Inverter 750 can supply a momentary surge in wattage however eve
2. USB connector NOTE If using more than one device the total combined wattage of both devices must not exceed 750 watts Press and hold the ON OFF button to turn the inverter ON The VOLT AGE IN indicator will glow and the digital display will show the DC input voltage Turn the device ON To show AC VOLTAGE OUT press the ON OFF button once Press the ON OFF button once again to show total wattage used by the device POWER OUT NOTE If there is a short circuit or power surge in the device 52 will display and an alarm will sound Press the ON OFF button to turn off the alarm If the 5 displays after several attempts there is a short circuit or the device requires more surge power than the inverter is capable of providing TO DISCONNECT THE INVERTER e Turn device OFF e Press and hold the ON OFF button to turn the inverter OFF e Unplug the device from inverter e If using the Accessory Plug unplug inverter from 12V DC accessory outlet If using the Battery Clamps unclamp inverter from 12V battery 036 6 DISPLAYS 6 1 LED Indicators The LED indicators identify the operating status of the inverter e VOLTAGE IN DC voltage of the battery vehicle electrical system or power supply e VOLTAGE OUT AC voltage supplied to device through the outlets e POWER OUT AC power wattage supplied to device through the outlets 6 2 Digital Display The values of the corresponding LED indicators will be shown in the digital display j 1
3. 1 O VOLTAGE IN O VOLTAGE OUT L E O POWER OUT If a problem develops during use an audio alarm will sound and one of the codes shown below will display To stop the alarm press the ON OFF button e bAd Inverter is not functional Call Customer Service to trouble shoot problem anywhere in the U S A 7 am to 4 30 pm Central Time Monday through Friday 1 800 SEARS 64 1 800 732 7764 e Hi B Vehicle s battery voltage is more than 15 5 volts Inverter will auto matically restart after the voltage drops below 15 0 volts e HIP The continuous load demand from the device exceeds 750 watts e Hat Inverter is overheated and automatically turns off for a period of 1 3 minutes to cool Make sure inverter is well ventilated It will automati cally restart after it cools e Lab Vehicle s battery voltage is less than 10 5 volts e 5L Short circuit power surge or overload in the device 7 OPERATING TIPS A typical automobile or marine battery at full charge will provide an ample power supply for the inverter The actual length of time the inverter can be operated depends on the age and condition of the battery and the amount of power being drawn by the devices To extend operating time when using power from a car that s not running turn OFF the device before starting the engine Then run the engine peri odically for approximately 10 minutes to recharge the battery Unplug the inverter when not in use
4. OWNER S MANUAL DieHard Power Inverter 750 Converts 12V DC Power to 110V AC Household Electrical Power Model No 200 71495 CAUTION Read all Safety Rules and Operating Instructions and follow them with each use of this product Sears Roebuck and Co Hoffman Estates IL 60179 U S A 00 99 000862 0508 IMPORTANT CHARGE IMMEDIATELY AFTER PURCHASE 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 1 10 1 11 IMPORTANT READ AND SAVE THIS SAFETY AND INSTRUCTION MANUAL IMPORTANT SAFETY INSTRUCTIONS Before using your Power Inverter 750 read and understand this Owner s Manual Keep the inverter well ventilated in order to properly disperse heat gener ated while it is in use Make sure there are several inches of clearance around the top and sides and do not block the slots of the inverter Make sure the inverter is not close to any potential source of flammable fumes gases or clothing Keep the inverter dry DO NOT allow the inverter to come into contact with rain or moisture DO NOT operate the inverter if you the inverter the device being operat ed or any other surfaces that may come in contact with any power source are wet Water and many other liquids can conduct electricity which may lead to serious injury Do not place the inverter on or near heating vents radiators or other sources of heat Do not place the inverter in direct sunlight The ideal air temperature for operation is between 50
5. n devices rated less than the maximum 750 watts can exceed the inverters surge capability and cause an automatic overload shutdown Make sure the device you are using is compatible with a modified sine wave inverter 4 1 4 2 4 3 4 4 9 1 5 2 9 3 9 4 CONNECTING CABLE ASSEMBLY Determine whether you ll be using the battery clamps 750 watt out put maximum or accessory plug 120 watt output maximum Make sure that there is no device plugged into inverter before making con nection Unscrew the positive red and negative black plastic connector knobs from the studs on the back of the inverter Slip the red positive ring terminal of the 12V accessory plug over the red positive stud Screw on the connector knob and tighten securely Repeat the same process for the black ring terminal Accessory Plug Push the 12V accessory plug firmly into a 12V acces sory outlet Battery Clamps Connect the red positive battery clamp to the posi tive battery terminal Connect the black negative battery clamp to the negative battery terminal taking care to shield eyes clothing and hands from battery acid USING INVERTER Determine the wattage of device being used The Power inverter 750 must be used with devices drawing 750 watts or less when being used with the Battery Clamps and 120 watts or less when using the Accessory Plug Plug the device to be operated into either the AC outlet of the inverter or
6. r contact at terminals Unplug and reinsert Power Inverter 750 Fuse is blown A blown fuse is usually caused by re verse polarity or a short circuit within the inverter The fuse is not user replaceable Inverter may be defective Call 1 800 SEARS 64 1 800 732 7764 for troubleshooting assistance 10 WARRANTY One Year Full Warranty on DieHard Power Inverter 750 If this Power Inverter 750 fails due to a defect in material or workmanship within one year from the date of purchase RETURN IT TO ANY SEARS STORE or OTHER DIEHARD OUTLET IN THE UNITED STATES FOR FREE REPLACEMENT This warranty gives you specific legal rights and you may also have other rights which vary from state to state Sears Roebuck and Co Hoffman Estates IL 60179 For information about troubleshooting call toll free from anywhere in the U S A 7 am to 4 30 pm CT Monday through Friday 1 800 SEARS 64 1 800 732 7764 o 7 o
7. to avoid battery drain A buzzing sound emitted from inexpensive sound systems is the result of ineffective filters in the sound system 8 SPECIFICATIONS 9 TROUBLESHOOTING PROBLEM ALARM IS ON Display shows SL Device has a short Cycle inverter power OFF and ON circuit or demands too much surge power If problem persists use a larger inverter or a smaller device Remove defective device Call 1 800 SEARS 64 1 800 732 7764 for troubleshooting assistance Display shows Lab 12 Volt battery is Recharge replace low battery too low Display shows Voltage in between 12 Volt battery is low 10 5 and 11 0 Volts Recharge replace low battery Inverter will automatically shut off after battery voltage reaches 10 5 volts Display shows H b DC Voltage in is If in a vehicle repair replace the alterna too high tor or charging system Use a properly sized and rated 12 Volt battery If input voltage returns to 15 volts or less the inverter will automatically restart Display shows HP Device demands Cycle inverter power OFF and ON more than 750 Watts continuous power If problem persists use a larger inverter or a smaller device Display shows Hat Inverter is too hot Increase ventilation to inverter Move inverter to a cooler area Reduce the power consumption of the device Inverter will automatically reset after cooling PROBLEM INVERTER DOES NOT TURN ON REASON SOLUTION Poo

Download Pdf Manuals

image

Related Search

Related Contents

動物駆逐用煙火 (連続発射式)  Powerware 5000/6000 VA Power Supply User Manual  USER`S MANUAL - Icon Heath & Fitness  Kapitel 3  Altronix BC1240  SDS Series User Manual  Sony SNC-DH120 - Network Webcams  Poulan 185143 User's Manual  Mode d`emploi IQSD-GSM  DISTRIBUTORE GPL DRESSER GLOBAL CENTURY  

Copyright © All rights reserved.
Failed to retrieve file