Home

Medio P213 - User Guide v1-0

image

Contents

1. October 2010 Revision 1 0 9 34 5 TAGSYS RFID Medio P213 Reader User s Guide e connecting goods 2 2 Communication Protocols 2 2 1 Tag to Reader Interface To read from TAGSYS RFID Tags to write to their memory or to activate their functions a wide command set is available For a complete list of embedded commands and their description please refer to the Medio P213 Command Set document 2 2 2 Reader to Host Interface When the Medio P213 reader is connected to an antenna it acts more as a protocol converter due to the wide range of tasks it can perform For more information about these tasks refer to the Medio P213 Command Set document Depending on the task requested by the user through the host interface the reader retrieves information from the TAGSYS RFID Tag or provides it with information using its own communication protocol The reader then converts the result of the operation into STX E protocol and returns the information to the host via the Reader to Host interface For more information refer to the Medio P213 Command Set document The Reader to Host interface has two operating modes 1 Normal Mode The Reader to Host interface is the slave of the master host system It waits for a valid command from the host performs the task and responds This bi directional communication is achieved via the STX E protocol For more information please refer to the Medio P213 Command Set document 2
2. Host To Reader Host RS 422 Interface Interface Reader 4 3 2 Installing the RS 485 Full Duplex Interface The RS 485 Full Duplex Standard requires 2 pairs of balanced lines one for transmitting and another for receiving data When testing your network installation make sure that all the connected readers are correctly supplied correctly configured Communication link selector and Terminaison resistor correctly connected cable connections If one reader is faulty on the network all the network may be mute to any command sent over the network Make sure that all the readers are preset with a different network address to avoid network conflicts By default a Medio P213 is preset with address O 16 34 Revision 1 0 October 2010 TAGSYS RFID e connecting goods Medio P213 Reader User s Guide Figure 5 Connection of the RS 485 Full Duplex Interface TX e e TX RX R RX Host RS 485 Full Duplex Interface R IR 3 R 1 gt x x Host To Reader Interface Host To Reader Interface Reader 1 Reader n Figure 5 shows how to connect the RS 485 Full Duplex Interface in a Multi drop network The balanced line TX and TX corresponds to the reader transceiver and must be connected to the receiver of the host and other reader transceivers or repeater A 120 Ohm
3. R R Host System MEDIO P013 GND GND R R 7 Use Rg or Rg resistors Tr Chassis 7777 Reference Earth safety 1 Reference 4 3 5 Electrical Signal Requirements The following table shows the electrical characteristics of the RS 422 RS 485 interface pins Table 6 RS 422 RS 485 Interface Pins Electrical Characteristics Pam como min Tye max uni Receiver Input Resistance 7V lt Vom lt 12V Je at e 21 CM x m E Receiver Input Differential Threshold Receiver Input Hysteresis RS 422 Transceiver Differential Output Voltage RS 485 Change In Magnitude of Transceiver Differential Output Voltage for Complementary Output States Transceiver Output Short circuit Current Lg October 2010 Revision 1 0 19 34 E TAGSYS RFID Medio P213 Reader User s Guide e connecting goods 5 Connecting Peripheral Devices 5 1 Using the Universal Input pin The reader input can be driven by a voltage source from OV up to 24V referring to the input ground A relay open chain transistor switch can also be used to connect the input pin and its ground Low level input voltage is defined to be in the range of 0 1 5V AHigh level input voltage is defined to be in the range of 3 to 25V 5 2 Using the Universal Output pin The output pin is an open drain power transistor that can drive a current up to 1 5A When activated the power transistor connects the
4. Reader Consumption vs Supply Voltage 25C 0 35 lt 0 3 c 0 25 9 E 0 2 3 0 15 F c 0 1 o E 0 05 o aan 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Supply Volts Consumption vs Temperature 12 V Supply Voltage RF On 0 275 027 S 0 265 2 0 26 0 255 0 25 0 5 10 15 20 25 30 35 40 45 50 55 Temperature C October 2010 Revision 1 0 29 34 2 TAGSYS RFID Medio P213 Reader User s Guide e connecting goods 9 3 Communication Link DC Characteristics and timings Absolute Maximum Ratings Input Voltages RX RX to GND 25V Output Voltages TX TX to GND 18 V Pam Seins mn Tue wx Uni 5 ev me ojv_ Cid sj v ressens i Cd s232 ouput voteze imdiwms en ses v oup sorore s ma ww pe Dam a sss RS 422 RS 485 Receiver Input Differential 200 200 mV Threshold RS 422 RS 485 Receiver Input Hysteresis 422 RS 485 Receiver RS 422 RS 485 Receiver Input Hysteresis Hysteresis RS 422 RS 485 Transceiver Differential RS 422 Output Voltage RS 485 fis RS 422 RS 485 Change In Magnitude of Transceiver Differential Output Voltage for 0 2 0 2 V Complementary Output States RS 422 RS 485 Transceiver Output 4250 m Short circuit Current RS 422 R
5. TAGSYS cannot be responsible in any way for and disclaims any liability in connection with the operation or performance of any product in which the Product is incorporated amp any equipment not supplied by TAGSYS which is attached to or used in connection with the Product or the Product with any equipment This warranty does only cover the Product to the exclusion of any such other equipment Optimal operation and performance of the Product are obtained by using TAGSYS readers by applying TAGSYS installation guidelines and by having your installation reviewed by a TAGSYS technical consultant TAGSYS warranty does not cover the installation maintenance or service of the Product and is strictly limited to the replacement of Products considered as defective by TAGSYS and returned according to the return procedure defined below in such case TAGSYS will at TAGSYS option either replace every defective Product by one new Product or refund the purchase price paid by Buyer to TAGSYS for the defective Product 10 2 Warranty Exclusions Defects or damages resulting from storage of the Product under conditions which do not comply with TAGSYS specifications or normal usage Defects or damages resulting from use of the Product in abnormal conditions abnormal conditions being defined as any conditions exceeding the ones stated in the product specifications Defects or damages from misuse accident or neglect Defects from
6. Q 7 TECHNICAL SPECIFICATIONS 7 1 MEDIO P213 TECHNICAL SPECIFICATIONS 8 MECHANICAL CHARACTERISTICS 8 1 DIMENSIONS AND GENERAL MECHANICAL INFORMATION 8 2 MARKINGS 9 ELECTRICAL CHARACTERISTICS 9 1 ABSOLUTE MAXIMUM RATINGS 9 2 PowER SUPPLY DC CHARACTERISTICS 9 3 COMMUNICATION LINK DC CHARACTERISTICS AND TIMINGS 9 4 ANTENNA ELECTRICAL AND TIMING CHARACTERISTICS 9 5 O ELECTRICAL CHARACTERISTICS 10 WARRANTY CONDITIONS 10 1 WARRANTY 10 2 WARRANTY EXCLUSIONS 10 2 1 GENERAL PROVISIONS 10 2 2 How TO RETURN DEFECTIVE PRODUCTS 19 20 20 22 23 23 23 24 24 25 25 25 26 26 27 27 27 28 28 29 30 31 32 32 32 33 33 6 34 Revision 1 0 October 2010 TAGSYS RFID e connecting goods Medio P213 Reader User s Guide 1 Introduction 1 1 General This document provides information about how to install and use the Medium Range Medio P213 TAGSYS RFID Tag Reader 1 2 Product Description TAGSYS Medio P213 RFID Tag Reader is intended for Original Equipment Manufacturer OEM applications The Medio P213 is Medium Range 13 56 MHz RFID reader designed to operate with any TAGSYS RFID Tag using C210 C240 C270 C370 C370 L S and 15015693 chips Medio P213 reader requires minimal computing power from the host workstation Windows based PC or UNIX environment It communicates easily with this host at a high speed using the simple TAGSYS enhanced communication protocol
7. TAGSYS RFID e connecting goods Medio P213 Reader User s Guide Revision 1 0 October 2010 5 TAGSYS RFID Medio P213 Reader User s Guide e connecting goods Publishing Information Disclaimer and Limitation of Liability All information herein is either public information or is the property of and owned solely by TAGSYS who shall have and keep the sole right to file patent applications or any other kind of intellectual property protection in connection with such information Nothing herein shall be construed as implying or granting to you any rights by license grant or otherwise under any intellectual and or industrial property rights of or concerning any of TAGSYS information This document can be used for informational non commercial internal and personal use only provided that 4 copyright notice below the confidentiality and proprietary legend and this full warning notice appear in all copies amp This document shall not be posted on any network computer or broadcast any media and no modification of any part of this document shall be made Use for any other purpose is expressly prohibited and may result in severe civil and criminal liabilities The information contained in this document is provided AS IS without any warranty of any kind Unless otherwise expressly agreed in writing TAGSYS makes no warranty as to the value or accuracy of information contained herein The document could inc
8. STX E Figure 1 Medio P213 TAGSYS RFID Tag Reader Application Overview ES P213 ES Reader OQ Tag Device Tag Device RS 232 422 485 Connection Antenna Host Sy aem The Medio P213 TAGSYS RFID Tag readers are easy to integrate because of its e smallsize e standard communication links October 2010 Revision 1 0 7 34 5 TAGSYS RFID Medio P213 Reader User s Guide e connecting goods 1 3 Key Features Table 1 Medio P213 Key Features Description Medio P213 Operating Frequency 13 56 MHz Compatibility C210 C240 C270 C370 C370 L S I8015693 chips Stand alone Mode C210 C240 C270 C370 C370 L S ISO 15693 chips Selectable Serial Link RS 232 RS 422 RS 485 Half or Full duplex Network Operating Yes I Os 1 input and 1 output Firmware upgradeable Yes 1 4 Delivery The Medio P213 TAGSYS RFID Tag Reader kit contains the following items Table 2 Package Contents Quantity Item 1 Medio P213 TAGSYS RFID Tag Reader 1 SMA BNC Adaptor 4 Configuration jumpers CD ROM including e Medio P213 Integrator s Guide e Medio P200u s P213 P232 3 Command Set e User friendly Px Explorer software provided for test and debug operations on Windows XP 200x Vista and Seven platforms e Tagsys Legacy Software Development Kit including o DLLs and ActiveX o Library Software Development Kit Documentation o set of source code and executable samples e Universal S
9. The common wire of the lamp is connected to the Output pin J3 2 and its supply to the Output Supply Pin J3 1 Note that the Output supply selector is configured to deliver the Power of the reader to the lamp The lamp needs a 24V power supply so the reader is supplied with 24V The consumption of the lamp is less than 1 Ampere so it can be connected directly to the reader output October 2010 Revision 1 0 21 34 5 TAGSYS RFID Medio P213 Reader User s Guide e connecting goods 5 3 Electrical Signal Requirements Table 7 provides the electrical DC characteristics Table 7 1 0 Interface Pins Electrical Characteristics _Conatons wn Typ mex unt 9 Jo v C Dmawmens e v C Om es C 22 34 Revision 1 0 October 2010 TAGSYS RFID e connecting goods Medio P213 Reader User s Guide 6 Stand alone Mode Stand alone Mode is designed to use the reader without using any command set While in this mode the reader is limited to tag reading The reader sends the tag ID to the Host System using ASCII protocol via the Reader to Host interface ASCII protocol is used in order to provide hexadecimal data that can be read by a variety of terminal programs e g Microsoft HyperTerminal 6 1 Stand alone Mode Features Table 8 lists the available features for each TAGSYS RFID Tag reader in Stand alone mode Table 8 Available F
10. Stand alone Mode The Reader to Host interface is independent from the host system Stand alone mode is used by the Medio P213 reader to read tags and send their identification data to the host system This transmission takes place in ASCII format While in this mode the reader cannot receive any commands For more information please refer to Section 7 Stand alone Mode 2 3 Peripheral Devices The I O interface manages 1 input and 1 output that can drive or check external peripherals The input is compliant with open collector drivers TTL CMOS voltage levels and industrial levels up to 25V The output consists of a gate controlled MOSFET transistor driver that can drive up to 1 5A It is safe from current and thermal overloads 5V current limited option is available to give TTL CMOS compliant levels The I O pins are mainly used for static applications such as reading sensors or driving LEDs relays or buzzers For more information refer to Section 6 1 Using the Universal Input pin and Section 6 2 Using the Universal Output pin 10 34 Revision 1 0 October 2010 TAGSYS RFID e connecting goods Medio P213 Reader User s Guide 3 Installing the Reader This section explains how best to install the Medio P213 TAGSYS RFID Tag Reader board The physical description of the reader board is given in Section 9 Mechanical Characteristics 3 4 Pin Connections Connection System Communication connector J1A
11. e Compliance with electrical characteristics see Electrical Characteristics chapter The antenna has a passive design that features 50 ohm O impedance characteristics at 13 56 MHz frequency 12 34 Revision 1 0 October 2010 TAGSYS RFID e connecting goods Medio P213 Reader User s Guide 4 Serial Communication Links Medio P213 TAGSYS RFID Tag Readers are based on a Master Slave communication system where the host system acts as the master and the reader as the slave In Stand alone mode the reader is used as a master and the host system becomes the slave The Host to Reader interface accepts an RS 232 RS 422 or RS 485 Full or Half Duplex communication links The communication type is selected using the jumpers on the Serial communication selector NUES TUNE Ja RS232 J3 Mode OIN RS422 Mode OMNES gt RS485 Mode 1 4 1 General Information on Data Acquisition Communication takes place by sending frames bytes on the communication link The bytes are transmitted LSB first with one start bit and one stop bit as shown in Figure 3 Figure 3 Structure of a Byte on the Communication Link LSB MSB P4 0 Start Bit 8 bits with LSB First Stop Bit October 2010 Revision 1 0 13 34 TAGSYS RFID Medio P213 Reader User s Guide e connecting goods Communication parameters are listed in Table 3 These
12. output pin and its ground The output transistor is protected against heating and current overload If an overload happens the output stops driving current automatically The output must be turned off to be re activated You can use the Configurable Supply Output pin of the IO connector to deliver a supply to an active system connected to the output You can set it to deliver the supply used to power the reader or a 45V supply limited by a 470 Ohms serial resistor by using the Supply Output Pin Selector with a jumper Output Supply Jumper selector J3 When the output is activated by the reader a green led near the IO connector turns on Beware that the LED will stay on while the output is in thermal or current overload state The figure above describes the output architecture Output supply jumper selector Main power supply 5VDC 4700 2 ne J3 3 20 34 Revision 1 0 October 2010 TAGSYS RFID e connecting goods Medio P213 Reader User s Guide Example 1 Connecting a LED to the Output F E S Anode The LED s cathode is connected to the Output pin and its anode to the Output Supply Pin Note that the Output supply jumper selector is configured to deliver 5V to supply the LED The internal serial resistor limits the current delivered to the LED Example 2 Connecting a Lamp 5W under 24 V to the Output using the reader supply
13. NT 1 INTRODUCTION GENERAL PRODUCT DESCRIPTION KEY FEATURES DELIVERY Roo 2 FUNCTIONAL OVERVIEW 2 1 FUNCTIONAL BLOCK DIAGRAM 2 2 COMMUNICATION PROTOCOLS 2 2 1 TAG TO READER INTERFACE 2 2 2 READER TO HOST INTERFACE 2 3 PERIPHERAL DEVICES 3 INSTALLING THE READER 3 1 PIN CONNECTIONS 3 2 POWER SUPPLY 3 3 ANTENNA 4 SERIAL COMMUNICATION LINKS 4 1 GENERAL INFORMATION ON DATA ACQUISITION 4 2 RS 232 INTERFACE 4 2 1 INSTALLING THE READER IN RS 232 MODE 4 2 2 SETTING THE HOST SYSTEM RS 232 COMMUNICATION LINK 4 2 3 ELECTRICAL SIGNAL REQUIREMENTS 4 3 RS 422 RS 485 INTERFACE 4 3 1 INSTALLING THE RS 422 INTERFACE 4 3 2 INSTALLING THE RS 485 FULL DUPLEX INTERFACE 4 3 3 INSTALLING THE RS 485 HALF DUPLEX INTERFACE 4 3 4 GROUNDING ARRANGEMENT p WWW oo oo AAN 10 10 10 11 11 12 12 13 October 2010 Revision 1 0 5 34 Medio P213 Reader User s Guide 5 TAGSYS RFID e connecting goods 4 3 5 ELECTRICAL SIGNAL REQUIREMENTS 5 CONNECTING PERIPHERAL DEVICES 5 1 USING THE UNIVERSAL INPUT PIN 5 2 USING THE UNIVERSAL OUTPUT PIN 5 3 I O ELECTRICAL SIGNAL REQUIREMENTS 6 STAND ALONE MODE STAND ALONE MODE FEATURES CUSTOMIZED TAG TYPE READING SERIAL COMMUNICATION TYPE CUSTOMIZED ASCII MESSAGE FORMAT REPETITION OPTION TRIGGER INPUT OUTPUT SETTINGS 6 2 ENABLING STAND ALONE MODE 6 3 DISABLING STAND ALONE MODE 6 1 6 1 6 1 6 1 6 1 6 1 6 1 O
14. S 485 Output Leakage Current 422 RS 485 RS 422 RS 485 Output Leakage Current Leakage Current oo u IEC 1000 4 2 Air Gap 4 kV Discharge ESD Protection on both pins IEC 1000 4 2 Contact 42 kV Discharge B eus o _ eus 5 sud _ iximercharectorime 30 34 Revision 1 0 October 2010 TAGSYS RFID e connecting goods Medio P213 Reader User s Guide 9 4 Antenna Electrical and Timing Characteristics Parameters Conditions min To wax Unt commons w rr Jool Figure 9 Output Power vs Temperature RF Power vs Temperature 12 V power Supply Power W 0 5 10 15 20 25 30 35 40 45 50 55 Temperature C 9 5 I O Electrical Characteristics Parameters min wax Unit Comments oe S Umawmens 3 v lt i LE DIC Foe L T October 2010 Revision 1 0 31 34 5 TAGSYS RFID Medio P213 Reader User s Guide e connecting goods 10 Warranty Conditions 10 1 Warranty TAGSYS warrants that this Product shall comply with the functional specifications set forth herein for a period of one year from the date of delivery to the Buyer This warranty is valid for the original Buyer of the Product and is not assignable or transferable to any other party
15. Sub D9 Male 2 Data transmitted to the reader for RS232 Mode TD signal for PC RX signal for RS422 or RS485 mode 3 Data sent by the reader for RS232 mode RD signal for PC TX signal for RS422 or RS485 mode 5 Ground 6 RX signal for RS422 or RS485 mode 9 TX signal for RS422 or RS485 mode All other pins are not connected Power supply connector J2A 2 5mm Jack type positive connection on the center pin IO Connector J3 Industrial terminal block screw connections 1 Configurable supply output 42 High power output 43 Ground for output 4 Universal input October 2010 Revision 1 0 11 34 5 TAGSYS RFID Medio P213 Reader User s Guide e connecting goods 5 Ground for input Programmation Connector HE10 type RF antenna connector J5 SMA type 3 2 Power Supply A DC power supply must be connected to J2 connector and must be able to withstand a peak current of 600 mA for 10V supply when the reader is powered on Please refer to Section 10 Electrical Characteristics for more details about reader consumption The power pins accept an input voltage between 10 and 24 V DC 3 3 Antenna The J5 connector is dedicated to an antenna that is required for reading TAGSYS RFID Tags This can be a TAGSYS antenna or a custom made model The choice of the antenna must take into account the following considerations e Physical area size of the TAGSYS RFID Tag e Strength of the reader
16. Tag Readers Audience This document requires familiarity with RFID technology It is intended for people in charge of installing and using the product Conventions Symbol Meaning CAUTION A note that advises users that a specific action could result in the loss of data or damage the hardware WARNING A note that advises users that a specific action may result in physical harm A note that provides additional information that helps the user to perform a task or obtain the best performance from the product If you need assistance Please contact your nearest TAGSYS sales representative or the TAGSYS welcome desk at Telephone 33 0 4 42 18 89 00 Fax 33 0 4 42 18 89 01 E Mail info tagsysrfid com Website http www tagsysrfid com Contact for Comments We welcome your feedback to help us provide high quality documentation For technical comments please contact our welcome desk Telephone 33 0 4 42 18 89 00 Fax 33 0 4 42 18 89 01 E Mail info tagsysrfid com Please remember to quote the Document Reference Number DOC 14227A0 your job title and your company October 2010 Revision 1 0 3 34 5 TAGSYS RFID Medio P213 Reader User s Guide e connecting goods Quality Issues TAGSYS implements stringent quality controls at all stages of its manufacturing process However should you find a defect with this product please notify your TAGSYS Quality Service representative using t
17. ard Y i 5 5 mm Version The values given have a tolerance of 0 2 mm 8 2 Markings The firmware application programmed in the reader and its version number are indicated on an adhesive strip on the processor unit of the reader 27 34 October 2010 Revision 1 0 5 TAGSYS RFID Medio P213 Reader User s Guide e connecting goods 9 Electrical Characteristics This chapter provides information about AC and DC and characteristics for all pins It also gives timing characteristics for the different interfaces 9 1 Absolute Maximum Ratings Parameter Value Ambient Operating Temperature to 550 Storage Temperature 20 to 70T Supply Voltage with respect to GND 25V Total Power Dissipation 3 0W Total Power Dissipation on Antenna 1W DC Current Allowed on Power Pin 400 mA Peak Current Allowed on Power Pin 600 mA Input Voltage Range on RS232 Receiver pin 25 V Input Output Voltage 25 V ESD Protection on RS232 pins 2 kV 28 34 Revision 1 0 October 2010 TAGSYS RFID e connecting goods Medio P213 Reader User s Guide 9 2 Power Supply DC Characteristics MEL EB A715 27 MR SR Power Power Input Voltage Voltage Power On Input Peak Power On Input Peak Input Voltage 12V 1260 mA RFOn RF IRFOn sd Power Input Current Input Voltage 12V 25 ma RF Off
18. eatures in Stand alone Mode C210 C240 C270 Philips ISO 15693 RS 232 T Serial Communication Type MM SR 422 Baud Rate Rate 4800 9600 19200 38400 57600 115200 4800 9600 19200 38400 57600 115200 bps Customized tag type reading Repetition Option Available STX ETX Characters Header String Customized ASCII message format Chip Description String ID String variable length End of Message String Input Trigger Available Output for active trigger information Available Output for tag reading information Available 6 1 1 Customized Tag Type Reading When using Medio P213 readers tags to be scanned can be configured using the Set Stand alone Mode command For more information refer to the Medio P213 Command Set document October 2010 Revision 1 0 23 34 5 TAGSYS RFID Medio P213 Reader User s Guide e connecting goods 6 1 2 Serial Communication Type When used in Stand alone mode Medio P213 readers can communicate via the RS 232 RS 422 or RS 485 link types Stand alone is not recommended in a network configuration 6 1 3 Customized ASCII Message Format When a TAGSYS RFID Tag is read its data is transmitted to the host in the form of an ASCII character frame Table 9 Customized ASCII Message Format TAGSYS RFID Tag is read x oD So So gt gE Bee 5 5 IO 9 O ui 2 z o a lt STX g
19. he dedicated Product Return Form Telephone 33 0 4 42 18 89 36 Fax 33 0 4 42 18 89 01 RoHS and WEEE Directives RoHS Restriction of the uses of certain Hazardous Substances TAGSYS certifies that this product is compliant with the European Directive 2002 95 EC for the restriction in Electric and Electronic Equipments RoHS of the use of the following hazardous substances e Lead e Mercury e Cadmium e Hexavalent Chromium e Polybrominated biphenyl flame retardants e Polybrominated diphenyl ether flame retardants This declaration is based on information provided by our suppliers and subcontractors WEEE Waste Electrical and Electronic Equipment This product bears the selective sorting symbol for waste electrical and electronic equipment WEEE This means that this product must be handled pursuant to European Directive 2002 96 EC in order to be recycled or dismantled to minimize its impact on the environment For further information please contact your local or regional authorities 4 34 Revision 1 0 October 2010 TAGSYS RFID e connecting goods Medio P213 Reader User s Guide Table of Contents PUBLISHING INFORMATION DISCLAIMER AND LIMITATION OF LIABILITY READ THIS FIRST AUDIENCE CONVENTIONS IF YOU NEED ASSISTANCE CONTACT FOR COMMENTS QUALITY ISSUES RoHS AND WEEE DIRECTIVES RoHS RESTRICTION OF THE USES OF CERTAIN HAZARDOUS SUBSTANCES WEEE WASTE ELECTRICAL AND ELECTRONIC EQUIPME
20. improper testing operation maintenance or installation Defects from alteration modification except modifications or adjustments specifically described in this Product reference guide adjustment or repair or any attempt to do any of the foregoing by anyone other than TAGSYS Any action on Product that prevents TAGSYS from performing an inspection and test of the Product in case of a warranty claim Tampering with or abuse of the Product Any use or incorporation by the Buyer or a third party of TAGSYS Product into life saving or life support devices or systems or any related products TAGSYS expressly excludes any liability for such use 32 34 Revision 1 0 October 2010 TAGSYS RFID e connecting goods Medio P213 Reader User s Guide 10 2 1 General Provisions This warranty sets forth the full extent of TAGSYS responsibility regarding the Product In any event TAGSYS warranty is strictly limited to at TAGSYS sole option the replacement or refund of the Products purchase price to TAGSYS of Products considered as defective by TAGSYS The remedy provided above is in lieu and to the exclusion of all other remedies obligations or liabilities on the part of TAGSYS for damages whether in contract tort or otherwise and including but not limited to damages for any defects in the Products or for any injury damage or loss resulting from such defects or from any work done in connection therewith or for consequential lo
21. ing fes v Rz onp soneron s m 4 3 RS 422 RS 485 Interface The RS 422 interface is compatible with EIA TIA 422 standards The RS 485 interface is compatible with EIA TIA 485 standards The RS 485 permits a balanced transmission line to be shared in Party Line or Multi drop mode As many as 32 receiver readers or repeaters pairs can share a Multi drop network If more readers are needed in the network balanced line repeaters can be used a repeater takes the place of a reader on the network 4 3 1 Installing the RS 422 Interface Figure 4 shows how to connect the RS 422 interface The balanced line RX and RX corresponds to the reader receiver and must be connected to the transmitter of the host The balanced line TX and TX corresponds to the reader transceiver and must be connected to the receiver of the host A 120 Ohm resistor should be added at the end of a transmission line in compliance with RS 422 specifications This resistor can be connected by connecting a jumper on HRS422 Terminaison selector When set to communicate according to RS 422 specifications the reader always holds its transceiver active and never switches it into Tri state mode The Host to Reader Interface should not be unplugged October 2010 Revision 1 0 15 34 5 TAGSYS RFID Medio P213 Reader User s Guide e connecting goods Figure 4 Connection of the RS 422 Interface
22. lude technical inaccuracies or typographical errors Changes are periodically added to the information herein Furthermore TAGSYS reserves the right to make any change or improvement in the specifications data information and the like described herein at any time Therefore TAGSYS assumes no liability and is not responsible for customer applications or product or software which include TAGSYS products TAGSYS HEREBY DISCLAIMS ALL WARRANTIES AND CONDITIONS WITH REGARD TO THE INFORMATION CONTAINED HEREIN INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE TITLE AND NON INFRINGEMENT IN NO EVENT SHALL TAGSYS BE LIABLE WHETHER IN CONTRACT TORT OR OTHERWISE FOR ANY INDIRECT SPECIAL OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO DAMAGES RESULTING FROM LOSS OF USE DATA PROFITS REVENUES OR CUSTOMERS ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF INFORMATION CONTAINED IN THIS DOCUMENT TAGSYS does not and shall not warrant that this product system equipment will be resistant to all possible attacks and shall not incur and disclaims any liability in this respect Even if each product is compliant with current security standards in force on the date of their design security mechanisms resistance necessarily evolves according to the state of the art in security and notably under the emergence of new attacks Under no circumstances shall TAGSYS be held liable for an
23. mer Service Representative 433 0 4 42 18 89 01 Return Procedure The product returned will go through stringent quality controls A final analysis report will be sent to you as soon as possible Please contact your Quality Service representative for further details 33 0 4 42 18 89 36 This product bears the selective sorting symbol for waste electrical and electronic equipment WEEE This means that this product must be handled pursuant to European Directive 2002 96 EC in order to be recycled or dismantled to minimize its impact on the environment For further information please contact your local or regional authorities 34 34 Revision 1 0 October 2010
24. ng goods Medio P213 Reader User s Guide 6 1 5 Trigger Input When the trigger capability is enabled a trigger state is used to start and stop the RF scanning The trigger is connected to the input of the reader Depending on the reply settings of the trigger the ASCII message can be sent during the trigger activity Repeated Read mode and Read Once mode are available or at the end of the trigger In this last case a message is always sent to the host system amp ifatag has been read the message contains its ID amp ifatag has not been read the message contains a No Message string that can be defined as shown in Table 11 Table 11 Customized ASCII Message Format TAGSYS RFID Tag is not read No Tag Found End of Message Start of Text Header String String String End of Text Descrotion lt STX gt TAGSYS 1979797977779 lt CR LF gt lt ETX gt p 0x02 Default Default Default 0x03 Size 1 0 to 16 0 to 16 0 to 16 1 character characters characters characters character Medio P213 Optional Optional Required Optional Optional 6 1 6 Output Settings The output of the reader can be used to monitor the trigger activity or the successful reads 6 2 Enabling Stand alone Mode Medio P213 can be set in Stand alone mode by using the Set Stand alone Mode command followed by a Reset Reader command For more information refer to the Medio P213 Command Set document You can al
25. oftware Development Kit including o Native DLL o NET Component o set of source code and executable samples Welcome Letter Product Return Form 8 34 Revision 1 0 October 2010 TAGSYS RFID e connecting goods Medio P213 Reader User s Guide 2 Functional Overview This section provides an overview of the architectural structure and peripheral devices of the Medio P213 TAGSYS RFID Tag Reader It also provides a summary of the special functions used to drive the reader board and describes the automatic features managed by the Central Processing Unit CPU 2 1 Functional Block Diagram The Medio P213 architectural structure is based on a CPU that drives all reader functions It manages communications between the host system connected to the Reader to Host interface and one or more TAGSYS RFID Tags using an antenna connected to the Tag to Reader interface It also drives 1 Universal Input and 1 Universal Outputs Figure 2 illustrates the general architecture of Medio P213 TAGSYS RFID Tag Reader Figure 2 Overall Medio P213 Architecture Peripheral Devices Medio P213 n 1 Input and TAGSYS RAD Tag Reader S dy Power Supply 1 Output uppl y Interface Central I Processng 4 IS Antenna Operating Unit N Y V Mode ASO Host Connedions Reader 4 Stard dore Protocol RS232 to Host 5 Interface STCE N Decoder n Encoder
26. onfigured by setting the reader in RS 485 Full Duplex mode and connecting pins RX and RX to pins TX and TX pins respectively on each reader of a network Figure 6 shows how to connect the RS 485 Half Duplex Interface in a multi drop network Figure 6 Connection of the RS 485 Half Duplex Interface j j gt gt 4 4 Q Q O O Host To Reader Interface Host To Reader Interface Host RS 485 Half Duplex Interface Reader 1 Reader n 4 3 4 Grounding Arrangement In order for the generator and the receiver to operate correctly a signal return path must exist between the reader grounds of the equipment at each end of the interconnection The reader reference may be established by a third conductor connecting the common leads of the devices or it may be provided by the connection from each equipment item to a ground reference Where the reader reference is provided by a third conductor the connection between the reader common and the third conductor must contain a certain amount of resistance e g 100 ohms to limit circulating currents when other ground connections are provided for safety 18 34 Revision 1 0 October 2010 TAGSYS RFID e connecting goods Medio P213 Reader User s Guide Figure 7 Grounding Arrangement for RS 422 RS 485 Third Conductor
27. parameters cannot be modified Table 3 Parameters for the Transmission of a Byte Parameter Value 4800 9600 19200 38400 57600 or 115200 bps Allowed Baud Rat depending on the reader settings Default Baud Rate 38400 Start Bit On Number of data bits 8 Parity None Stop bit 1 The maximum period between the transmission of bytes is 10 ms regardless of the applicable baud rate 42 RS 232 Interface 4 2 1 Installing the reader in RS 232 mode To use the RS 232 interface you can connect a NULL MODEM RS232 cable to the suitable COM port of a PC Please configure the Serial Communication Selector as shown in Chapter 5 4 2 2 Setting the Host System RS 232 Communication Link The host system RS 232 communication link must be set as shown in Table 4 Table 4 RS 232 Allowed Settings on the Host System Baud Rate Accordingly to the reader Baud Rate Configuration pe SSCS 14 34 Revision 1 0 October 2010 TAGSYS RFID e connecting goods Medio P213 Reader User s Guide 4 2 3 Electrical Signal Requirements Table 5 shows the electrical characteristics of the RS 232 interface pins Table 5 RS 232 Interface Pins Electrical Characteristics Geneng Tye wax Ont es as Ummemuwamelw me Umsmrmuwawena me v mmnmanmem 7 vorago Sw
28. resistor should be added at the end of the two transmission lines in compliance with RS 485 specifications This resistor can be connected by connecting a jumper on the RS422 RS485 Termination Selector on the end line reader When set to communicate using the RS 485 interface the reader always holds the transmission lines before the start of any communication and returns to Tri state mode at the end of communication The host system should do the same The reader can be unplugged from the balanced lines 4 3 3 Installing the RS 485 Half Duplex Interface RS 485 Half Duplex Standard requires only 1 pair of balanced lines for both transmitting and receiving data October 2010 Revision 1 0 17 34 5 TAGSYS RFID Medio P213 Reader User s Guide e connecting goods When testing your network installation make sure that all the connected readers are correctly supplied correctly configured Communication link selector and Termination resistor correctly connected cable connections If one reader is faulty on the network all the network may be mute to any command sent over the network Make sure that all the readers are preset with a different network address to avoid network conflicts By default a Medio P213 is preset with address 0 The balanced line TX4 and TX corresponds to the reader driver and must be connected to the driver of the host and other reader drivers or repeater The RS 485 Half Duplex interface is c
29. so use the Px Explorer software provided with the reader 6 3 Disabling Stand alone Mode The Medio P213 can be reset in Standard mode by sending the S character using the communication interface for example HyperTerminal October 2010 Revision 1 0 25 34 5 TAGSYS RFID Medio P213 Reader User s Guide e connecting goods 7 Technical Specifications 7 1 Medio P213 Technical Specifications Table 12 Medio P213 Technical Specifications s SSS Communication interface RF Output Power 1W Typical Operating temperature 556 Storage temperature 20 to 70T Mechanical fixation Mechanical fixation with 4 screws M3 M3 Conformit FCC parts 15 Depending on configurations Communication protocol in T Standard mode TAGSYS specific STXE 2 ASCII protocol in Stand alone User configurable mode 26 34 Revision 1 0 October 2010 TAGSYS RFID Medio P213 Reader User s Guide e connecting goods 8 Mechanical Characteristics 8 1 Dimensions and General Mechanical Information Figure 8 Medio P213 Reader Mechanical Dimensions 90 gt 165 Coe 4 4 mm P 82mm gt mm DOE EUN ma DEMEURE Cc COR ou T NES K Connector i Standard Version i o N geuecdqo m 3 3 3 3 lose Noctes Y SubD9 13 5 mm 1 6 mm Connector o Ps 11 5 mm Stand
30. ss whether based upon lost goodwill lost resale profits impairment of other goods or arising from claims by third parties or otherwise TAGSYS disclaims any explicit warranty not provided herein and any implied warranty guaranty or representation as to performance quality and absence of hidden defects and any remedy for breach of contract which but for this provision might arise by implication operation of law custom of trade or course of dealing including implied warranties of merchantability and fitness for a particular purpose 10 2 2 How to Return Defective Products The Buyer shall notify TAGSYS of the defects within 15 working days after the defects are discovered Defective Products must be returned to TAGSYS after assignment by a TAGSYS Quality Department representative of an RMA Return Material Authorization number No Products shall be returned without their proof of purchase and without the acceptance number relating to the return procedure All Products shall be returned with a report from the Buyer stating the complete details of the alleged defect Call 33 0 4 42 18 89 36 for return authorization and shipping address If returned Products prove to be non defective a charge will be applied to cover TAGSYS analysis cost and shipping costs If the warranty does not apply for returned Products due to age or application of a warranty exclusion clause a quote for replacement will be issued and no replacement
31. t TAGSYS Gia lt CR LF gt lt ETX gt 0 02 Default P Default 0x03 C210 2 to 16 characters o o 0 5 f o 9 o 9 C240 2to16characters 9 Size amp S o 9 xt dd E C270 2 to 16 characters d e os ISO15693 2 to 16 characters Medio P213 Optional Optional Optional Required Optional Optional Medio P213 readers can decode all chips in Standalone mode Only the ID field is required in the return ASCII message All other fields are optional The ID field length is programmable the default lengths are given in Table 10 Table 10 Default ID Field Lengths Chip Type Default ID Field Length C210 chip 16 Total memory C240 chip 16 Block 0 Page 0 C270 chip 16 Block 0 and Block 1 15015693 chip 16 UID 6 1 4 Repetition Option The reader constantly attempts to read any chips present in the field When a chip ID is detected the reader can send the information to the host in one of 2 modes 1 In Repeated Read mode the reader returns a chip s ID to the host with each successful read operation 2 In Read Once mode the reader only returns the ID of a chip if the previous read corresponds to a different chip or if all reading attempts have failed 4 times this feature makes it possible to detect a chip s potential exit out of the field 24 34 Revision 1 0 October 2010 TAGSYS RFID e connecti
32. will be granted until a valid purchase order is received If no purchase order is received within 30 days after the date of TAGSYS quote TAGSYS will return the products and charge the analysis cost and shipping costs All replaced Products shall become the property of TAGSYS The Product Return Form is included on the following page This form should accompany any product you need to return to TAGSYS for analysis in the event of a problem October 2010 Revision 1 0 33 34 TAGSYS RFID Medio P213 Reader User s Guide e connecting goods Product Return Form Customer Profile Company Contact eese ttatenta ta BOSE cod cerunt sein an tad bas gana Contact e mail occas Contact Phon e u a reete bannis wiasasasassssassnanssanssunssusssesussssussususesusesesesssssssseaseanensnsnsnsnusus Contact PA uu a n RON RERO NEN State hs ios erede td ede ka ZipCode ET enis Order identification Product Name Invoice u ga aka ga aan abaan Order Number OEF TOME TAA eT E Return Quantity Tree To inform TAGSYS of this return please email it to RMA tagsysrfid com Address to ship the product with this document attached TAGSYS QUALITY DEPARTMENT TAGSYS 785 Voie Antiope Ath lia III 13600 La Ciotat France To inform TAGSYS of this return please also fax it to your Custo
33. y third party actions and in particular in case of any successful attack against systems or equipment incorporating TAGSYS products TAGSYS disclaims any liability with respect to security for direct indirect incidental or consequential damages that result from any use of its products It is further stressed that independent testing and verification by the person using the product is particularly encouraged especially in any application in which defective incorrect or insecure functioning could result in damage to persons or property denial of service or loss of privacy 2000 2010 TAGSYS All rights reserved Microsoft Visual C Windows and Windows NT are either registered trademarks or trademarks of Microsoft Corporation in the U S A and or other countries I Code is a registered trademark of Philips Tag lt is a registered trademark of Texas Instruments Printed in France TAGSYS 785 Voie Antiope Ath lia IIl 13600 La Ciotat France Tel 33 0 4 42 18 89 00 Fax 33 0 4 42 18 89 01 Document Reference DOC14227A0 2 34 Revision 1 0 October 2010 TAGSYS RFID e connecting goods Medio P213 Reader User s Guide Read This First Welcome to the TAGSYS range of products operating at the 13 56 MHz frequency This range of products is used to implement high quality RFID systems for demanding applications This document provides information about how to install and use Medium Range Medio P213 TAGSYS RFID

Download Pdf Manuals

image

Related Search

Related Contents

RPC UNIT - Hitachi  SK-3P - SKP Pro Audio  Samsung 20" LED Монитор серии D XL20    NAS System User Manual  2012.1.29(日)開催  parts catalogue news  

Copyright © All rights reserved.
Failed to retrieve file