Home
User guide LUMEAL GA motorisation
Contents
1. LUMEAL GA USER GUIDE lt Z L U Lu 12 quarter 2013 Presentation of motorization RU 2 B 90 w gt CORE 2 Description of a complete cycle Maximum opening of the sash Stopping the sash during movement Anti pinching Other functions Automatic au US CINE LIN SONR aan 8 EU 8 Kanaane ra ee 8 MOE NE 8 Maintenance LUMEAL GA TECHNAL TECHNAL LUMEAL GA Kit motorisation LUMEAL reference GA3700 User guide Your LUMEAL TECHNAL joinery is equipped with a motorization system allowing automatic locking unlocking and opening closing of the sash We recommend that you read this instruction manual to understand the functions of this motorization PRESENTATION OF MOTORIZATION A DRIVE Sash drive is performed by a cable located on the upper part of the window Ensure that you do not damage this during any cleaning or maintenance operations The sash is linked to the cable by the drive If it is necessary to dismount the sash do not forget to first disconnect the drive from the sash Securing screw between the drive and the sash B CONTROL The motorization may be controlled via a switch wired or radio control or a remote control comprising as a minimum an open and a close command When a remote control or radio control switch is replaced it is necessary to check compatibility with the receiver In case of doubt consult your installer l
2. L GA Kit motorisation LUMEAL reference GA3700 User guide ANTI PINCHING The motorization automatically detects any obstacles during opening or closing During closing Obstacle detection Reverse movement of sash for 2 s and stob On user command re start of opening or closing at low speed During opening Obstacle detection Reverse movement of sash for 2 s and stop On user command re start of closing only and at low speed LUMEAL GA TECHNAL TECHNAL LUMEAL GA Kit motorisation LUMEAL reference GA3700 User guide VI OTHER FUNCTIONS A AUTOMATIC ADJUSTMENT After an obstacle triggered stop during opening the motorization will automatically perform a learning cycle sensing of opening and closing stops over the next complete cycle A learning cycle is also automatically initiated every 50 cycles B FREQUENCY OF USE To avoid any damage related to excessive motor heating motorization use frequency is limited to three open close cycles over a period of 5 minutes Beyond this limit degraded mode is enabled the user can open or close but must hold the command button down The sash now only moves at low speed and a beep is heard Degraded mode is disabled automatically after 10 minutes without sash movement C MANUAL OPERATION In the event of a power cut or motorization problem it is possible to manually lock and unlock the sash using the lock button on the joinery The sa
3. l DESCRIPTION OF A COMPLETE CYCLE gt The sash is closed and locked Opening command 1 Unlocking of the sash resulting in the movement of the handle 2 Opening of the sash 3 Automatic stop at the end of the opening LUMEAL GA TECHNAL TECHNAL LUMEAL GA Kit motorisation LUMEAL reference GA3700 User guide gt The sash is open gt Closing command 1 The sash closes 3 Locking of the sash resulting in the movement of the handle al Note sash travel speed varies over the course of the cycle Ill MAXIMUM OPENING OF THE SASH Sash stop position on opening can vary from one cycle to another This phenomenon is normal and does not constitute a defect An end of travel stop readjustment is performed automatically every 50 cycles Once the sash has stopped in its open position it is possible to manually move the sash to the end of travel stop to obtain maximum opening To do this maintain the opening button the sash is placed in its maximum opening position in contact with the end of travel stop Note after this operation on closing movement is performed at low speed IV STOPPING THE SASH DURING MOVEMENT The sash may be stopped at any time during its opening or closing travel via the control point The sash then always re starts movement at low speed in either direction up to its completely closed or open position LUMEAL GA TECHNAL TECHNAL V LUMEA
4. sh can also be moved manually Caution Manually moving the motorized sash must only be performed if absolutely necessary and does not under any circumstances represent an alternative to motorized operation it is recommended to leave the sash closed until the problem has been resolved The manual movement of the sash requires a certain amount of force and must be performed as progressively as possible and without sudden jerks D LOCKING FAULT On opening if unlocking does not occur normally 3 beeps sound and the sash does not move gt Make another attempt to open using the control point If this fails unlock manually using the lock button On closing if locking does not occur normally a slow beep sounds for 5 minutes or until the sash is locked correctly gt Perform locking either manually using the lock button or by restarting a cycle using the control point In the event of repeated improper operation contact your installer Vil MAINTENANCE The motorization does not require any particular maintenance Ensure that the lower rail is kept as clean as possible so that the sash slides as easily as possible In the event of a significant drop in sash travel speed or motorization malfunction contact your installer who will perform a system verification TECHNAL 1 quarter 2013 Document n 5380 001 All reproduction translation and adaptation reserved for all countries The law of March 11 1957 prohibi
5. ts the copy or reproduction for use other than limited to private use of the copier Any reproduction made in whole or in part in any form without the agreement of the author is illegal and constitutes infringement of copyright sanctionned by clauses 425 onwards of the penal code Follow us on Hydro Building Systems 270 rue L on Joulin BP 63709 31037 Toulouse Cedex 1 France www technal com Technal a brand of Hydro Document n 5380 001 Y HYDRO