Home

Operating instructions DALI MULTIeco

image

Contents

1. T1 N DIP 12345 xX xX ON mm x x aa x a x gt lel X lhe x lle T mmm 2 Cy mm T2 N x DIP 12345 x xX ON mm x X allel x 2 a x Mimi T LIL xX le 1 0 Ol Adjusting the operating mode Via DIP switch 1 and 2 Brightness control operating mode DIP switch 1 ON DIP switch 2 ON The following functions are switched on and off using DIP switches 3 4 and 5 see Table T1 K Presence detection Brightness control The device is delivered with both functions switched on Does not switch on via sensor Manual switch on required Automatic switch off after expiry of the switch off delay time motion independent Brightness reduction operating mode DIP switch 1 ON DIP switch 2 OFF Tia OFF Standby 30 ON Standby 50 k OFF Standby 10 OFF mja Las The following functions are switched on and off using DIP switches 3 4 and 5 see Table T2 Presence detection 2x Automatic switch off of the luminaires after expiry of twice the switch off delay time Does not switch on via sensor Manual switch on required Motion independent Manually switching luminaire on and off Via short press Note In the Brightness reduction operating mode manual switch off of the luminaires is not poss
2. motion sensor flat 4008321047342 LS PD MULTI3 Cl Light and motion sensor for ceiling installation 4008321916648 Y CONNECTOR Branching element for the connection of additional sensors 4050300803135 Y CONNECTOR Screw Branching element with screw terminal for connection of additional sensors and for connection of MULTleco systems with central presence detection 4008321916686 ECO CI KIT Cable strain relief for the independent installation of the MULTleco control unit e g ceiling installation 4008321392091 SENSOR KIT Adapter for the surface mounting of the LS PD Cl sensor 4008321916662 Page 4 of 4
3. persons are present the brightness drops to a fixed stand by value of 50 30 or 10 after an adjustable delay time Automatic switch on and automatic switch off during periods of prolonged absence can be activated and deactivated using various modes Design The control unit is made up of the following components Adjusting screw for switch off delay time A Sensor connection B DIP switch C c Pushbutton connection D G os DALI MULTleco on F or L Control line connection E Load contact F see Setting the switch off delay time e Power supply connection G Operation Symbols Pushbutton on the Luminaire on i luminaire Q O gt Switchon Luminaire off 5 M Luminaire I gt 0 Switch off x fl X 2010 lashes DALI_MULTleco_ba1010en_we1 01 indd D Short press eee 3 lt 0 5 s 0 i OSRAM GmbH control Kunden Service Center L Confirmati Customer Service Center CSC 0538 wA orike seting Steinerne Furt 62 86167 Augsburg Manual Germany Double click dimming Tel 49 0 1803 677 200 kostenpflichtig charges apply Presence detection Fax 49 0 1803 677 202 N detection of small movements www osram com www osram de 4008321371300 Page 1 of 4 Operation cont ol ol
4. pushbutton less than 30 seconds ago gt Wait until the delay time expires The workplace is not fully within the detection area of the sensor gt Move your hand in front of one of the sensors If the LED in the sensor does not flash realign the sensor to the workplace Presence detection is deactivated gt Activate presence detection by briefly pressing the push button Presence detection is switched off in the selected operating mode gt Select a suitable operating mode No artificial light is necessary gt See Function Presence detection cannot be deactivated Brightness was manually changed within the last 30 seconds gt Wait until the delay time expires Presence detection is switched off in the selected operating mode gt Select a suitable operating mode Luminaire does not react as expected to the press of a button Pushbutton was pressed too long or too short gt See Manually changing brightness Manual brightness change is locked gt See Locking and releasing pushbutton functions Appendix Accessories The CE requirements to EN 60928 are fulfilled The EMC requi rements to EN 61547 are fulfilled Conformity with the relevant EU directives is confirmed by the CE symbol Designation Description Product number LS PD MULTI 3 Light and motion sensor LS PD MULTI 3 B Light and motion sensor movable 4050300802138 4050300803081 LS PD MULTI 3 FL Light and
5. OSRAM Description Purpose and application The DALI MULTleco control unit controls the lighting at the workplace and in offices according to the level of daylight and DALI M U LTleco the presence of persons to increase comfort and save energy The control unit can be installed in luminaires e g floor stan ding luminaires or in suspended ceilings Function The control unit can be operated in two different operating ma cag modes see also Setting the operating mode ee L 100 240V DALI MULTleco Sensor i H 50 60H2 umpmmratn 51330 u Brightness control zi 7 oon sgun Fe Q tdi The sensors measure the brightness in the area to be regulated SA oH cE 8 am J 1 and keep this to an adjustable set value by introducing artificial light according to the amount of daylight available The sensors also detect the presence of people When the level of daylight is sufficient or people are no longer present the connected luminaires switch off after an adjustable delay period 10 s 60 min Control Unit Operating instructions Luminaire OFF Artificial light required Luminaire ON Luminaire manually switched off 30 s ago Brightness control presence detection and automatic switch on can be activated and deactivated using various modes Brightness reduction If persons are present the luminaires are dimmed to an adju stable brightness value If no
6. ible Changing the brightness manually Note Function is locked if necessary see Locking and relea sing pushbutton functions Via long press Each repeated long key button press causes a toggle between increased brightness and decreased brightness The brightness control is deactivated until the next time the luminaire is switched on Adjusting the set value brightness value Note Function is locked if necessary see Locking and relea sing pushbutton functions In the Brightness control operating mode the setting corre sponds to the set value for the automatic brightness control tip make the setting when there is little daylight In the Brightness reduction operating mode the setting corre sponds to the fixed brightness value to which it is dimmed when movement is detected Set the desired brightness Double click Confirmation Luminaire flashes Page 2 of 4 Operation cont fond Note Function is locked if necessary see Locking and relea sing pushbutton functions When presence detection is active the green LED on the sensor lights up briefly each time motion is detected Deactivate presence detection Switch on if necessary Double click Confirmation Luminaire switches off Green LED on the sensor lights continuously The presence detection is activated again the next time the luminaire is switched on by pushbutton if presence detection is s
7. ilure Page 3 of 4 Operation cont Troubleshooting If you cannot remedy the fault please contact the Customer Service department of the luminaire manufacturer Luminaire does not function No mains voltage available gt Check whether the green LED is lit Use a voltage tester to test if mains voltage is present Illuminant is faulty gt Replace illuminant The luminaire was switched off via the pushbutton gt Switch on luminaire The sensor is exposed to excessive amounts of ambient light gt Cover the sensor and observe the behaviour of the luminaire A set value for the brightness cannot be specified Preset reference is locked gt Unlock the set value specification Brightness control is switched off in the selected operating mode gt Select a suitable operating mode Brightness is not adjusted to the selected set value Pushbutton was not pressed within 30 seconds after setting the set value presence detection is activated gt Double click within 30 seconds after carrying out manual dimming Brightness control was not started until 5 seconds after the set value was adjusted gt Wait until the delay time expires Brightness control was deactivated by a manual operation gt Switch luminaire off and on again Brightness control is switched off in the selected operating mode gt Select a suitable operating mode Presence detection is not functional The luminaire was switched off by
8. witched on and active through selection of the corresponding operating mode Lock preset reference and deactivation of the presence Q detection Set the minimum brightness and press the pushbutton for another 15 seconds Confirmation Luminaire flashes Locking the reset reference and manual brightness change Set the maximum brightness and press the pushbutton for another 15 seconds O 2 Confirmation Luminaire flashes gt 30s Re releasing all pushbutton functions Press the pushbutton for 30 seconds Confirmation Luminaire flashes Note When the presence detection is activated each time a movement is detected the countdown of the time restarts KA Turn the adjusting screw to the required setting 5 15 30 To the left shorter min 10 s 1 60 To the right longer max 60 min 404 time Note When presence detection is active the load contact L is only opened when the switch off delay time has expired This means the control unit can be used at the same time as pre sence dependent control of the room ventilation for example Behaviour after a power failure After a power failure the luminaire remains switched off until the next time presence is detected or a pushbutton is operated If the Automatic switch off function is switched on in the Brightness reduction operating mode the luminaire switches on with the standby value after a power fa