Home
Manual EMS-2-Plotter-System - CONTA-CLIP
Contents
1. CONTACLIP CONTACLIP EMS 2 Easy Marking System EMS 2 Operating Instructions Release March 12 2012 CONTACLIP amp CONTACLIP EMS 2 Easy Marking System Operating Instructions EMS 2 o 1 a ee nese 2 2 NEWS SUPICO un Tee 3 11011 Rui 4 4 E PO UA EE E E A A 5 SAEI AO ee 6 6 Cleaning and product care nenne nnns 9 71100605511 enit see a 10 Oe TFOUDIESIIOOUNgG een 11 9 Technical INIOHNAUON nenne OO 12 10 Instructions for packaging the plotter EMS 2 13 o A 14 CONTACLIP B 1 Introduction Thank you for purchasing the EMS 2 a flexible plotter that helps you label marking elements quickly and easily ll Rugged construction in stylish aluminium E Labelling area A3 size 440 mm x 305 mm A4 size 220 mm x 305 mm E Easy to change fixtures to suit a variety of marking elements ll Automatic fixture recognition largely avoids the need to select marking elements E Optimum plotter pen seal The pens can be stored in the plotter s pen station ll Auto calibration no adjustment necessary E Capable of labelling marking elements up to 10 5 mm in height opecial solutions for up to 15 mm are possible ll Universal power supply of 100 240V AC E The special start up function for th
2. eApparaten far endast anv ndas torra utrymmen eDra inte ur kontakten ur eluttaget genom att rycka i sladden eReparationer av denna apparat inklusive utbyte av el sladd far endast utforas av fackman Sicherheitshinweise eBewahren Sie die Gebrauchsanweisung sorgfaltig auf eDieses Gerat entspricht den anerkannten Regeln der Technik und den einschlagigen eSicherheitsbestimmungen fur Geratesicherheit eElektrische Anschlussbedingungen und Angaben auf dem Typenschild m ssen bereinstimmen eGeratenutzung nur in trockenen Raumen eNetzstecker nicht am Kabel aus der Steckdose ziehen eReparaturen an diesem Ger t einschlie lich der Austausch der Netzzuleitung d rfen nur von Fachkraften durchgef hrt werden 14 CONTACLIP Instructions de s curit eConserver ces instructions dans un endroit s r eCet appareil r pond aux normes techniques et satisfait toutes les r gles de s curit el e courant utilis doit tre identique celui sp cifi sur l appareil eNe pas utiliser cet appareil dans un environnement humide eD brancher l appareil en tirant sur la prise pas sur le cable e Toutes les r parations y compris le remplacement des composants lectriques doivent tre effectu es par un technicien qualifi Instrucciones de Seguridad eConserve las instrucciones de seguridad en un lugar seguro eEste equipo cumple con todas las normas t cnicas de seguridad el ctrica y requisitos de seguridad el ctrico a
3. If the storage holders become soiled over time you can replace them The procedure for changing the storage holders can be found in the accessories section gt Please note Should you wish to use other plotter pens with HP fixing system you must insert them directly into the writing arm holder and ensure that they are not stored in the pen station Stop view key If the stop view key is activated while the plotter is in action the job will pause immediately and the plotter pen will move into the top right hand corner The red light will signal the interruption Pressing the key again will calibrate the writing arm and the plotter will continue with the job The red light will go out Important Inserting a pen into the writing arm holder by hand can involve inadvertently moving the writing arm and compromising calibration After inserting the pen press the stop view key twice in succession to recalibrate the system Cursor keys Pen up down key These keys can be used to move the writing arm manually in all directions The pen up down key lowers and raises the plotter pen The system must be in stop mode gt Please note These key functions are not used for normal operation They are intended solely for adjusting settings and carrying out servicing CONTACLIP Placing the fixtures on the Plotter There are eight pin stops on the plotting area where up to four different fixtures can be loaded Different fixtu
4. data downloaded from PC No labelling is taking place even though a plotter pen has been inserted Poor labelling quality uneven line thickness missing items Check whether the mains plug and connecting plug are plugged in correctly Check whether the socket being used is functioning properly Is the green light on the power supply illuminated If not please replace the power supply Is the interface cable connected properly Replace the data cable if necessary Is the correct interface on the PC being used Check whether the plotter pen has dried out or if there is sufficient ink in the pen Refill or replace the pen if necessary The plotter pen tip may be soiled Clean the tip carefully using a lint free cloth dipped inspecial cleaning fluid Replace the plotter pen if necessary 11 B 9 Technical Information EMS 2 plotter specifications Type of plotter Maximum plotting area Plotting speed Plotter pen Ports Control language Buffer Drive Pen station Addressable resolution Repeat accuracy Repeat accuracy after pen change Power supply Power supply input voltage Power supply input current Power supply output voltage Power supply output current Environmental conditions Safety certificate Interference safety compliance Dimensions Weight CONTACLIP Flatbed plotter A3 440 mm x 305 mm A4 220 mm x 305 mm Max 40 cm s Special plotter pens with HP fixing Pa
5. dths Plotter Pen D Y mmm Bloisnmm 025mm Elo 35 mm Mlo somm Mo7omm mm 1 I Cleaning Set Pen Cleaner B Fluid p gc Kit for Pen Station Ss y Dust Protection Cap p TO EXCHANGE A SEALING UNIT IN THE PEN STATION To remove the sealing station To insert the sealing station To adjust the sealing station from the pen station into the pen station in the pen station TO REMOVE ONE OF THE SEALING UNITS FROM THE PEN STATION Firstly open the pen station by pressing the Open Close button Apply the enclosed key to the sealing unit as illustrated and carefully lever the sealing unit out of the holding device TO INSERT AND ADJUST ONE OF THE SEALING UNITS Insert the new sealing unit into the pen station Press the sealing unit carefully up to the limit stop into the aluminium tube Now by use of the key adjust the sealing unit until the key is parallel with the plotter surface The opening at the side of the sealing unit should now be centered TO EXCHANGE THE PRIMING PLATES for starting the plotter pen The small plates can be removed by pulling them out sideways Insert the new ones by sliding them into the guide at the side of the clamping device until they fit tightly 10 E 8 Troubleshooting CONTACLIP If your plotter EMS 2 is not functioning correctly please check the following Device fails to switch on Plotter does not respond to
6. e olotter pen Pause or stop plotte activity ON OFF buttons The ON OFF buttons are used to activate and deactivate the device When the plotter is switched on the writing arm moves to the top right hand corner of the labelling area and auto calibration takes place The green light comes on when the system is ready for use and to receive data from the PC Clear buffer If the EMS 2 contains data the yellow light will come on You can delete this data by pressing the Clear buffer key To do this the system must be in stop mode red light on CONTACLIP Open close pen station Before using the EMS 2 insert the plotter pen with the desired tip width into the pen station Important Only plotter pens of the types shown here may be used as the sealing system is designed specifically for these plotter pens Using other plotter pens and writing instruments may damage the device To insert plotter pens into the pen station press the Penstation open close key This is only possible when the system is in stop mode When the pen station has been opened you can insert the plotter pens into the corresponding storage holders and then re close the pen station by pressing the open close key again gt Please note Do not leave the pen station open for extended periods as there is a danger the pens will dry out You can leave plotter pens in the pen station because the optimised seal largely prevents pens from drying out
7. e plotter pens ensures neat labelling right from the very first marking element ll PC interfaces centronics parallel and USB ports E Control language HPGL E O interface for connecting peripheral equipment e g handlings etc Bl Material held in place by vacuum contact option E Possible to update EMS 2 software through PC connection and downloading from the Internet CONTACLIP E 2 Items supplied Please check you have received all the items supplied with your labelling device see list below Please retain the packaging in case you need to return the device The following items are supplied as standard E 1 Plotter EMS 2 ll 2 Power supply with corresponding mains power cord E 3 USB cable E 4 Operating instructions ZCONTACLIP ZConTacLip EMS 2 ires Markasg 5rasiem L Ly EMS 2 CONTACLIP B 3 Product overview 1 Plotting area 2 Pen station 3 Sealed storage holders in pen station 4 Start up writing area 5 Pin stops for fixtures 6 Vacuum supply for the individual segments 7 Penholder 8 Drop pen unit 9 Vacuum connection point 10 Mains connection 11 Interface for optional external devices 12 Centronics printer port 13 USB port 14 Control panel control keys 15 Writing arm 16 Fixture recognition sensors CONTACLIP 8 4 Setting up the Plotter EMS 2 LOCATION A dry dust free room is the ideal environment for the plotter If possible do not install t
8. he device in damp or very dusty areas Do not expose the system to direct sunlight Please ensure that the connections on the right hand side of the device are accessible at all times Position the EMS 2 firmly on the work surface where it is to be used ensuring it is level Please ensure that the writing arm can move freely and is not obstructed by other objects CONNECTIONS Plug the device into a correctly installed mains socket using the power supply included with the product The power supply features a variable AC input voltage of 100 240V 50 60Hz The power connection can be replaced by way of adapter plugs Plug the connector from the output cable on the power supply into the top right hand side of the plotter Then hook up the device using the USB cable provided The respective port is located on the right hand side of the EMS 2 FZTCONTACLIP B 5 Operation Once you have installed the EMS 2 and connected the power supply and data cable you can switch the plotter on Important Before switching the device on please ensure that there are no objects on the writing plotting area which might prevent the writing arm from moving freely All settings and commands are entered using the control panel v 2530 Cw d Switch device onjoft eoo em C apu Manual movement in X and Y directions lower the plotter pen Delete data downloaded from PC Open and close pen station to insert remov
9. plicables en el pa s de uso el a fuente de alimentaci n debe corresponderse con los valores de tensi n y corriente citados en la placa de identificaci n del producto e as caracter sticas de la fuente de alimentaci n a utilizar con el producto son las siguientes entrada 100 240Vca 50 60Hz 700mA Salida 24Vcc 1 25A eUtilice el equipo en condiciones secas nicamente eDesconecte el equipo de la red de alimentaci n por medio de la ficha nunca tirando del cord n e Todas las reparaciones incluyendo el reemplazo del cord n de alimentaci n deben ser realizadas por personal t cnico calificado 15
10. rallel centronics USB Level 1 1 Based on HP GL 7475A 16 MB Two phase step motor Max 4 plotter pens with double seal 01 mm 05 mm 05 mm with optimum pen Via separate power supply with exchangeable mains power connection 100 240V AC 50 60Hz A max 24 V DC 1 25 A max In use 10 C 35 C 35 75 relative humidity Storage 10 C 50 C 10 90 relative humidity EN 60950 1 EN 55022 B EN 61000 4 2 to 6 EN 61000 4 11 A3 660 mm A4 440 mm x 440 mm x 125 mm A3 Approx 8 kg A4 Approx 6 kg 12 Z CONTACLIP BI 10 Instructions for packaging the plotter EMS 2 two corner pieces with inlay accessory box 13 CONTACLIP M 11 Safety instructions Safety instructions eKeep the operating instructions in a safe place This device complies with all recognised technical standards and all relevant safety regulations e The mains power supply used must correspond with that specified on the name plate eUse in dry conditions only eDisconnect the device from the mains socket by pulling the plug not the cord eAll repairs including replacement of mains power supply components must be performed by a qualified service technician Sakerhetsforeskrifte eForvara bruksanvisningen p saker plats eDenna apparat ar tillverkad enligt modern teknik och i enlighet med gallande sakerhetsforeskrifter for elektriska apparater eKontrollera uppgifterna p typmarket innan anslutning till eluttag
11. res are available depending on the size of the marking elements They can occupy one two or four segments on the plotting area Please note When fitting fixtures or inserting marking elements into the fixtures it is possible for the writing arm to be moved out of place altering the calibration If the writing arm is moved press the stop view key twice in succession to recalibrate the system Different size fixtures 1 segment 2 segments 4 segments Placing the elements in the fixtures Choose the appropriate fixture for the elements to be labelled and insert the elements carefully into the fixture You can also add the elements first and then place the fixtures in the plotter CONTACLIP E 6 Cleaning and product care Protect the EMS 2 from dust and other dirt When not in use cover the plotter A special cover is available as an accessory Wipe the device occasionally after use with a dry lint free cloth or a mild cleaning agent If the pen station storage holders are heavily soiled please replace them The description for the sealed unit can be found in the section on accessories Important Under no circumstances use harsh cleaning products to clean the plotter Never oil the mechanical parts of your plotter CONTACLIP B 7 Accessories available in six tip widths Mo1smm l25mm 035mm Mosomm Mo7omm mm Ink Cartridges Pen storage stand coa oum available in six tip wi
Download Pdf Manuals
Related Search
Related Contents
MAD-X User's Guide SCF v1 eMachines H3120 User's Manual Mesurer la qualité des soins Husqvarna YTH160 User's Manual ツーパイヘビ一ー5 取扱説明書 PeakTech® 1210/1215 Bedienungsanleitung LaCie d2 Quadra Hard Drive 500GB Copyright © All rights reserved.
Failed to retrieve file