Home
Addendum to the Operating Instructions.st4.book
Contents
1. Drive Technology Drive Automation System Integration Services UMA AA MATA EURODRIVE SEW EURODRIVE GmbH amp Co KG Addendum to the P O Box 3023 D 76642 Bruchsal Germany Phone 49 7251 75 0 Operating Instructions Fax 49 7251 75 1970 sew sew eurodrive com www sew eurodrive com MOVIMOT MM D Retrofit Set for AC Motors DRS DRE DRP Edition 02 2010 16742419 EN General Information Structure of the safety notes 1 General Information 1 1 Structure of the safety notes Pictogram Example gt Signal word Meaning Consequences if disregarded DANGER Imminent danger Severe or fatal injuries WARNING Possible dangerous situation Severe or fatal injuries General danger A A CAUTION Possible dangerous situation Minor injuries Specific danger e g electric shock NOTICE Possible damage to property Damage to the drive system or its environment HO INFOR Useful information or tip MATION Simplifies the handling of the drive system 1 2 Right to claim under limited warranty A requirement of fault free operation and fulfillment of any right to claim under limited warranty is that you adhere to the information in the MOVIMOT documentation Therefore read the operating instructions before you start working with the unit Make sure that the operating instructions are available to persons responsible for the plant and its operation as well as
2. MM22D to MM40D BW2 0 823 136 2 1 The scope of delivery includes 2 screws M4 x 8 Addendum to the Operating Instructions MOVIMOT MM D Retrofit Set AC Motors DRS DRE DRP Mechanical Installation Scope of delivery of the retrofit set 2 Mechanical Installation 2 1 Scope of delivery of the retrofit set Check the scope of delivery of the MOVIMOT MMO3D MM40D retrofit set for completeness using the following figure IA D E F G i 783979147 A Terminal box gasket E PE screw l Drive ID module B Connection box F Connection cable J 2 screws C 4 screws G Cover with inverter D Connection pcb H 4 screws Parts B and D through J are already installed when the retrofit set is delivered 2 2 Assembly A DANGER Disconnect the drive from the power supply before removing the terminal box cover Severe or fatal injuries from electric shock e Disconnect the drive drive from the supply system and secure it against unintentional reconnection to the voltage supply e Then wait at least for 1 minute 1 Unscrew the terminal box cover and ZA remove the power supply cable Result as shown in the figure to the right a A AYO ZA N O ZI 3 Oe x O lll 8 o Brake control optional GANO PRL only with brakemotors 9007200042328587 Addendum to the Operating Instructions MOVIMOT MM D Retrofit Set AC Motors DRS DRE DRP Mechanical In
3. 11 Insert the connection board D into the terminal box and secure it using 2 screws J G Tightening torque 2 0 3 3 Nm 18 29 Ib in ele N Be careful not to damage or squeeze AG the cables N GN LB lo See D J 788423563 Addendum to the Operating Instructions MOVIMOT MM D Retrofit Set AC Motors DRS DRE DRP Mechanical Installation Assembly 12 Only for brakemotors Connect the connection cables of the BE brake as follows e Redtoterminal X1 13 o jelle White to terminal X1 14 x x X o F a e Blueto terminal X1 15 v S m Tightening torque of the terminals 0 8 1 1 Nm 7 10 lb in BE 9007200043226123 13 Only for motors without a brake Install the BW braking resistor in the terminal box using 2 screws o jle Tightening torque 1 4 1 6 Nm Sl lS Se 12 14 lb in Connect the BW braking resistor to BW1 BW2 terminals X1 13 and X1 15 Tightening torque of the terminals 0 8 1 1 Nm 7 10 lb in i Terminal X1 14 must not be assigned 9007200043479691 14 Place the MOVIMOT inverter onto the terminal box and secure it using 4 screws Tightening torque 3 0 Nm 27 Ib in 2602175
4. to person who work independently on the unit You must also ensure that the documentation is legible 1 3 Exclusion of liability You must comply with the information contained in the MOVIMOT documentation to ensure safe operation of MOVIMOT and to achieve the specified product characteristics and performance requirements SEW EURODRIVE does not assume liability for injury to persons or damage to equipment or property resulting from non observance of these operating instructions In such cases any liability for defects is excluded Addendum to the Operating Instructions MOVIMOT MM D Retrofit Set AC Motors DRS DRE DRP General Information Other applicable documentation 1 4 Other applicable documentation This additional information does not replace the detailed operating instructions Only electrical specialists are allowed to perform installation and startup observing applicable accident prevention regulations and the MOVIMOT MM D with AC Motors DRS DRE DRP operating instructions 1 5 Available retrofit sets NOTICE Only brake motors are allowed to be retrofitted with Rated motor voltage AC 230 400 V 50 Hz Rated brake voltage AC 230 V for MMO3 MM15 AC 120 V for MM22 MM40 No retrofit sets are available for UL units MOVIMOT retrofit sets are configured to order This is the reason why retrofit sets do not have a part number 1 5 1 Retrofit sets for DRS motors 1400
5. 499 After successful retrofitting startup the MOVIMOT drive according to the MOVIMOT MM D with AC Motors DRS DRE DRP operating instructions Addendum to the Operating Instructions MOVIMOT MM D Retrofit Set AC Motors DRS DRE DRP
6. M4 MM07D 1 1 DRE90M4 MM11D A DRE DRE90M4 MM11D 1 5 DRE90L4 MM15D 4 DRE DRE90L4 MM15D 2 2 DRE100M4 MM22D 4 DRE DRE100M4 MM22D 3 0 DRE100LC4 MM30D L DRE DRE100LC4 MM30D 4 0 DRE132S4 MM40D L DRE DRE132S4 MM40D Power kW Motor MOVIMOT retrofit set MOVIMOT drive 1 1 DRE80M4 MM11D A DRE DRE80M4 MM11D 1 5 DRE90M4 MM15D A DRE DRE90M4 MM15D 2 2 DRE9OL4 MM22D A DRE DRE9O0L4 MM22D 3 0 DRE100M4 MM30D DRE DRE100M4 MM30D 4 0 DRE100LC4 MM40D A DRE DRE100LC4 MM40D Power kW Motor MOVIMOT retrofit set MOVIMOT drive 0 75 DRP90M4 MMO07D 4 DRP DRP90M4 MM07D 1 1 DRP90L4 MM11D A DRP DRP90L4 MM11D 1 5 DRP100M4 MM15D 4 DRP DRP100M4 MM15D 2 2 DRP100L4 MM22D 4 DRP DRP100L4 MM22D 3 0 DRP112M4 MM30D 4 DRP DRP112M4 MM30D 4 0 DRP132M4 MM40D L DRP DRP132M4 MM40D Power kW Motor MOVIMOT retrofit set MOVIMOT drive 1 1 DRP90M4 MM11D A DRP DRP90M4 MM11D 1 5 DRP90L4 MM15D DRP DRP90L4 MM15D 2 2 DRP100M4 MM22D DRP DRP100M4 MM22D 3 0 DRP100L4 MM30D DRP DRP100L4 MM30D 4 0 DRP112M4 MM40D DRP DRP112M4 MM40D For motors without mechanical brake we recommend to connect an integrated braking resistor BW The braking resistor is not included in the scope of delivery of the retrofit set and must be ordered separately MOVIMOT type Braking resistor Part number MMO3D to MM15D BW1 0 822 897 31
7. rpm A 2900 rom A Power kW Motor MOVIMOT retrofit set MOVIMOT drive 0 37 DRS71S4 MMO3D 4 DRS DRS71S4 MM03D 0 55 DRS71M4 MMOS5D 4 DRS DRS71M4 MM05D 0 75 DRS80S4 MMo7D 4 DRS DRS80S4 MM07D 1 1 DRS80M4 MM11D A DRS DRS80M4 MM11D 1 5 DRS90M4 MM15D 4 DRS DRS90M4 MM15D 2 2 DRS90L4 MM22D 4 DRS DRS90L4 MM22D 3 0 DRS100M4 MM30D 4 DRS DRS100M4 MM30D 4 0 DRS100LC4 MM40D 4 DRS DRS100LC4 MM40D Power kW Motor MOVIMOT retrofit set MOVIMOT drive 0 55 DRS71S4 MMO5D A DRS DRS71S4 MMO05D 0 75 DRS71M4 MM07D A DRS DRS71M4 MMO7D 1 1 DRS80S4 MM11D A DRS DRS80 4 MM11D 1 5 DRS80M4 MM15D A DRS DRS80M4 MM15D 2 2 DRS90M4 MM22D A DRS DRS90M4 MM22D 3 0 DRS90L4 MM30D A DRS DRS90L4 MM30D 4 0 DRS100M4 MM40D A DRS DRS100M4 MM40D Addendum to the Operating Instructions MOVIMOT MM D Retrofit Set AC Motors DRS DRE DRP 1 5 2 Retrofit sets for DRE motors 1400 rpm A 2900 rom A 1 5 3 Retrofit sets for DRP motors 1400 rom X 2900 rom A 1 5 4 Braking resistors for motors without brake General Information Available retrofit sets Power kW Motor MOVIMOT retrofit set MOVIMOT drive 0 75 DRE80M4 MMO07D 4 DRE DRE80
8. stallation Assembly S N A Ca Ce ooocooA 8SO00 amen x Q EE Yee SSO00900 1 2 3 A 9007200042336011 2 If present disconnect the brake control cables 1 and 2 3 Remove the nuts 4 and jumpers 3 7 6 5 A B p S Ee Yoon SO 000 9007200042421003 Unscrew the lower part of the terminal box 5 Remove the gasket 6 Clean the sealing surface 7 N Oo Sf Place the new gasket A onto the terminal box B Addendum to the Operating Instructions MOVIMOT MM D Retrofit Set AC Motors DRS DRE DRP Mechanical Installation Assembly 8 Place the connection box B onto the motor and secure it using 4 screws C Tightening torque 3 1 5 3 Nm 29 47 lb in Check that the gasket is fitted correctly The recess for the terminal board on the underside of the connection terminal must point toward the fan guard C 9007200042429195 9 Plug the connection cables F onto the bolts of the terminal board as shown in the wiring diagram Tighten the connection cables using the previously unscrewed nuts Tightening torque 1 6 2 0 Nm 14 18 Ib in 10 Connect the connection cables F to P a the terminals 1 on the connection se board according to the wiring diagram RS to the right 9007200043039883
Download Pdf Manuals
Related Search
Related Contents
Brodit ProClip 512554 LevelOne BOH-1000 camera housing Dell™ OptiPlex™ 740 Systeme Benutzerhandbuch LS-T30 Systèmes d`enceintes TV - DEFICIENT X LG DN899 BROCHURE COMMERCIALE Maxiempaste Extra Liso Interior 裏表紙 (782KB) CCN-7924S-40 IP Environmental Bullet Packing Copyright © All rights reserved.
Failed to retrieve file