Home
Profi-TAP C1AP-100 User & Installation Manual
Contents
1. _ TAP e mail sales profitap com website www profitap com
2. copying you may disconnected the USB Key and proceed Otherwise use the USB Key for installation procedure and decide to connect Profi TAP to a second USB2 0 port and remove USB Key when finished b Connect the Tap to Network Connect into the network using Category 5 UTP cables Network Port A to DCE by straight Cable to DTE by cross over cable Network Port B to DTE by straight Cable to DCE by cross over cable The maximum distance between any of the connected devices is 90mtr c Connect the USB port Connect the USB port to a free PC MAC USB2 0 port the Power LED lights d Install the Driver Install the driver according to your Operating System Current available drivers are located on the USB Key at the driver section or within your installation folder on your harddisk Supported OS are Windows ME 98 CE 5 0 Windows XP 2000 Vista 32 bit Windows XP 2003 Vista 64 bit MAC OS X 32 bit 64 bit x86 PowerPC Linux kernel 2 6 0 2 6 13 Linux kernel 2 6 14 2 6 22 Please check the last driver releases for your Operating System on section Downloads at www profitap com e Setup the TAP Network Card In any case we recommend to set an IP address The installed TAP driver as under section d is represent as a Network Interface Device to your PC Config ure the IP Protocol Stack IP address 192 168 0 1 Submask 255 0 0 0 Note Leave Gateway or DNS Settings undefined Profi TAP is now ready to use as sourc
3. harddisk If you downloaded the latest version from the website unzip the downloaded file jpnstat zip or rar to the selected folder Note The Statistic Tool requires Java Runtime Environment installed on your PC Java Runtime is available as free download for various Operating systems at www java com Refer URCE Rri eooo ON next page PROFI TAP C1AP 100 User Manual 6 Usage of Statistic Tool The Statistic Tool is a stand alone application designed for Profi TAP In addition to the display of CRC faults via LED on the front of Profi TAP device you will get detailed information about RX and TX lines of the monitored link with the Statistic Tool Once Profi TAP is connected to the Network and the USB2 0 port it will monitor all 7 layers at the link To display the traffic in a listing or graphical chart you need to run this Java application as prior installed under section 5 The Stat Mode uses the TAP exclusively by default for using the native Tap Mode for analyzer toggle between Modes by selecting the checkbox Stat or TAP Mode Locate the executable file JPNstat jar in the folder Statistics Tool or any other defined location as installed Double click on JPNstat jar to execute the appli cation in a upcoming window File Setup ii Rx Stream Tx Stream Sa Totes ffs Oo w te O e Pte e e e e Stat Mode Cre errors 0 0 0 0 0 0 0 0 0 g DETE Total G2 0 100 0 62 68 0 100 0 68 ra 64 127 54 0 5226 54 54 o 7
4. 50 54 Clear All Ditts 428 255 7 0 11 29 7 14 0 20 59 14 Pricer tst hn ay 256 511 4 0 6 45 4 3 0 44i 3 Cear ARs 512 1023 0 o0 0 o o o 0 o Clear Rx Difi 1024 1518 0 o Pa s z an ooon Undersized El p ear AlTe Oversized 0 i E Clear Tx Ditt Collision 0 C i 0 E Jabber ae 0 0000000 1 RX stream TX stream 10 00 10 01 10 02 10 03 10 04 10 05 10 06 10 07 10 08 10 09 Other Cre error s Undersized s Oversized s Collision s Jabber s Fr Jul G4 Sample view As an overview without any Analyzer this troubleshooting tool will identify in one quick view the bandwidth or any low layer faults by chart or graph prior to a deeper investigation performed by an analyzer jar to Java An undefined error may occur if any other program will Note Make shure that the Operating System associates the extension X execute this file PROFI TAP C1AP 100 User Manual 7 additional information 2 x RJ45 8 pins Connectors 1 x USB Type B Power 5V over USB 300mA Latency Neon Ons Monitor 1 packet length Dimensions 24 x 55 x 102mm Operation O to 50 C Storage Temperature 22 to 70 C Relative Humidity 10 to 90 no condensing Compliance CE FCC class A Disclaimer The information in this document is subject to change without notice The manu facturer makes no representations or warranties with respect to the contents hereof and specifically disclaims any
5. a EEE OJI Al Industrial Ethernet Protocol Analyzer Sa ee eee User Manual C1AP 100 Index General Information Getting Started Orientation Interface connectors Activity Link CUSTOMER SUPPORT INFOR 3 Errors MATION for technical support Phone 33 388 101830 Installation Fax 33 388 101835 Profi TAP Usage with an Analyzer 2 rue de la Mairie oo 67203 Oberschaeffolsheim Installing Statistic Tool France Website www profitap com E mail support profitap com Additional Information Power Using Statistic Tool N OO Ww oO BW WW WD W ZEN PROFI TAP C1iAP 100 User Manual 1 General Information The Profi TAP is a straight forward solution In Line it sees and monitors all 7 protocol layers It captures and merges Full Duplex traffic at Wire Speed 200Mb It requires only one USB 2 0 480Mb port It is a cost effective ultra compact easy to use solution The hardware setup takes less than a minute Profi TAP is invisible to the network and does not interfere in auto negotiation speed or duplex settings The Permanent Network Link feature guarantees per manent network connectivity and no package loss also when power fails or the USB port is disconnected One LED shows Power two LEDs shows Link Activity two more CRC Errors on monitored link Profi TAP is designed to work with 3 party software like Wireshark Ethereal Optiview Etherpeek etc The USB Key holds the ne
6. cessary drivers and powerful analysis software Due the design of Profi TAP unlike ordinary NIC s it passes on information about MAC Level faults like CRC etc There are several ways to indicate this kind of errors via LEDs on the front of Profi TAP panel via the Statistic Tool or with the used analyzer 2 Getting started Unpacking the device you will find the following components Profi Tap C1LAP 100 USB Key with Drivers amp Analyzer Software Statistic Tool on USB Key 1 USB Cable 0 8 mtr 2 RJ45 Patch Cable 2 mtr pouch for protection PROFI TAP ciap 100 user manual 2 Overview 2 1 Interface Connectors There are 2 RJ45 ports Port A and B connected to the network and 1 USB connector to the Analyzer 2 2 Link Activity Two Link Act LEDs indicate Link on and Activity blink 2 3 Errors Two Error LEDs indicate CRC errors flashing on on the network link front view 2 4 Power The rear Power LED is on if USB Port is connected In case of a Power Failure the uninterrupted link in the network guarantees permanent network connectivity also when USB port is not connected rear view PROFI TAP C1AP 100 User Manual 3 Installation a Insert the USB Key for accessing copying the contents to a installa tion folder Note It is recommended to copy the contents to your harddisk first if there is no more other USB2 0 port available After
7. e for your installed analyzer or for use with the Statistic Tool see next page to connect to an analyzer PROFI TAP C1AP 100 User Manual 4 Usage with an Analyzer f Selecting Profi TAP as source for your Analyzer Start your existing analyzer and select the new virtual driver appearing at the select NIC window refer to your Analyzer s Manual or User Help about how to select a Network Card g Using alternate Wireshark Etherreal As one option you may install an alternate Analyzer from USB Key as provided or from various other sources Note Always follow the specific instructions shown by the installation wizard of the selected Analyzer In addition perform step f to enable Profi TAP to be you favourite resource Verify the listing on our website regarding supported Analyzers Make shure to use latest available version if any problem occurs with Profi TAP 5 Installation Statistic Tool h Install Statistics Tool optional Using the Statistics Tool requires the installation of a Java based application lo cated on the USB Key or your installation folder on your local hard disk Copy the folder Statistics Tool with its subdirectories to a location on your harddisk Using the Statistics Tool requires the installation of a Java based application lo cated on the USB Key or your installation folder on your local hard disk Locate the folder Statistics Tool on USB Key or your installation folder on the
8. implied warranties of merchantability or fit ness for any particular purpose The manufacturer reserves the right to revise this publication and to make changes in the content hereof without obligation of the manufacturer to notify any person of such revision or changes Warranty and Liability Profi TAP warrants that this product is free from defects in material and work manship at time of shipment The warranty period is one year from the date of purchase Profi TAP assumes no liability for products that have been subjected to abuse modification misuse or if the model or serial number has been al tered tampered with defaced or removed Profi TAP is not liable under any contract negligence strict liability or other legal or equitable theory for any loss of use of the product inconvenience or damages of any character whether di rect special incidental or consequential including but not limited to damages for loss of goodwill loss of revenue or profit work stoppage or malfunction Copyright This publication including all photographs and illustrations is protected under international copyright laws with all rights reserved Neither this manual nor any of the material contained herein may be reproduced without written con sent of the author Trademarks The trademarks mentioned in this manual are the sole property of their owners Rev 4 2 2008 PR OFI phone 33 0 388 1018 30 fax 33 0 388 1018 35