1. PULSE Relay LED with blinking light BISTABLE or STEP Relay 6 2 4keys remote memorization The memorization consists in a sequence of pressures of P1 Example 2 4 keys remote memorization with the following links KeyA gt Relay 1 Key B gt Relay 2 Key C gt Relay 3 Key D gt Relay 4 a P R1 switches off R2 lits R2 switches off R1 lits and on again and on again g a ue E H H O Keep P1 pushed for 2 Release Push key A of the Press P1 Release Push key B of the sec until LD1 P1 transmitter to P1 transmitter to switches on memorize memorize R4 switches off and on and after 2 sec R3 lits a5 R3 switches off R4 lits switches off and on again K gt H i Press Release Push key C of the Push P1 Release Push key D of the pi P41 transmitter to P4 transmitter to memorize memorize Fig 3 ERC r3 Ea R THESMART LIVING
2. the following procedure it s possible to calculate the number of transmitters memorized The display is carried out by the led R3 Red and R4 Green Push P1 and verify that R1 switches on Keep on pushed P1 until R1 switches off and than release it At this point starts a sequence of flashes of the 2 leds R3 RED ed R4 GREEN The sequence is the binary expression of the transmitter keys memorized The final number can be calculated making reference to the following table Led on ili 24 oF 4 5 6 ie Green led value 2 4 8 l G2 w Tab 3 Red led value 0 0 0 0 0 0 0 Example 4 Sequence LR LR LV LV LR LR LR Final number 0 04 4 8 0 0 0 12 Therefore in the memory are memorized 12 transmitter keys 6 3 Memory full At the end of the memorization of the 85th transmitter key R3 and R4 make a shork blinking If you try to memorize more keys R3 and R4 make 2 flashes and the memorization fails 7 TRANSMITTERS ERASURE 7 1 Single transmitter cancellation Keep the push button P1 pushed for 2 sec until R switches on release and push P1 again to select the led of to the relay associated to the transmitter key to delete Push the key of the transmitter to delete example key A the receiver confirms the erasure with 2 flashes of R3 Red and R4 Green R1 switches on again for 4 sec stable or blinking according to the position of the dip switch and then switch off definitively To canc
3. Guarantee Guarantee period 24 months from the productions date placed inside In this period if the appliance has any malfunction due to a defective component it will be repaired or replaced by the manufacturer The warranty doesn t cover the plastic box The assistance will be performed at the manufacturer site ERONE DIN GUIDE 4 RELAY RECEIVER SEL2641R433 RBD J Manufactured by Elpro Innotek SpA t Via Piave 23 1 31020 S Pietro di Feletto TV Italy E Tel 39 0438 450860 Fax 39 0438 455628 THE SMART LIVING Web www erone com email info erone com IS RBDERUK Rev 0 del 24 09 2008 USE AND INSTALLATION MANUAL R THE SMART LIVING Remarks Safety measures For a perfect functioning of the device read carefully this manual and follow all the indications since an inadeguate use can make damages to the device Declaration of Conformity Elpro Innotek Spa as manufacturer declares that the following appliances SEL2641R433 RBD fullfills the requirements of the European Directives 73 23 CEE 89 336 CEE and 99 05 CE and the Regulation EN 60950 1 1 INTRODUCTION The 4 relay DIN guide receiver DIN SEL2641R433 RDB is a superheterodyne receiver with 4 clean contacts outputs lt can drive automation devices a nd alarm systems with max contact power of 3 5 KW The relay contacts are NO NC The operating mode of the relays can be pulse or step with dip switch selection The memorizatio
4. ay 3 21 NC Relay 2 16 NC Relay 4 22 NC Relay 2 17 C Relay 4 23 C Relay 2 18 NO Relay 4 24 NO VE RONE VERONE THE SMART LIVING 4 FEATURES e Memory for 85 transmitter keys e Single tx code memorization and erasure with a single push button e Single tx or full memory erasing e Programmable operating mode for the relays pulse or step e Display of the number of stored users e 4 inputs for emergency extra push buttons 5 INSTALLATION 5 1 Positioning The location choice is very important for the best result of the installation The following conditions have to be followed fix the receiver far from interference sources as informatic systems allarm systems or other radio emissions the distance between 2 receivers should be more than 1 5 m ATTENTION 1 The power 12 Vac Vdc must be provided by a power supplier certified according to Safety Regulations and must come from a SELV circuit protected against short circuit 2 The appliance must be installed in an enclosure able to assure a Class or Il Safety Class against electric chock 3 The protection devices against extracurrents and short circuits must be provided by the building electric installation when the relays are inserted on the supply of appliances connected to the distribution network 4 Apply a max power of 3 5 KW 230 Vac to the relay contacts In case of connection of the relays to dangerous voltages foresee a sectioning
5. circuit to disconnect these parts 5 If there are mixed type loads 230V and 12 V connected to the relay terminals these must be connected by interposing a null relay example R1 230V R2 230V R3 empty R4 12V 5 2 Antenna if you connect an antenna not provided fix the wire to the terminal 4 and the shield to the terminal 3 if you use the piece of wire 16 5 cm provided connect it to the terminal 4 5 3 Auxiliary inputs The receiver is equipped with 4 extra inputs 11 12 13 14 e COM which allow to connect 4 NO auxiliary push buttons fot the direct activation of the relays The push buttons PR1 PR2 PR3 PR4 on fig 1 not provided act on the relays like the remote controls keys in pulse or step mode according to the settings of dip switch S1 a THE SMART LIVING 6 REMOTE CONTROLS MEMORIZATION The memorization of the remote controls can be carried on in sequential way by using only P1 Each step is confirmed by the led R1 R2 R3 R4 The procedure consists in a sequence of pressures of P 1 The lighting of the leds R1 R2 R3 R4 is cyclic at each pressure of P1 a led is turned on and the preceding led is turned off fig 2 The led light is stable or blinking according to the setting of the corresponding dip switch see cap 8 45 5 Ha R1 R2 R3 R4 Fig 2 6 1 Relay condition The relay configuration pulse or step is displayed by the led light LED with stable light
6. el more keys of the same transmitter B C D it s necessary to wait for the R1 switching off and repeat the procedure from the beginning Example 3 Erasure of the key A from relay 1 R1 lits i N R1 lits R1 switches on RED GREEN again for 2 sec si N 3 1 N Q 1 fe a a a 3 a a O O O S ai j R3 and R4 flash twice s imultaneously Keep P1 pushed for 2 sec Release Push key ex A of the until R1 switches on P1 transmitter to delete Fig 4 A 7 2 Memory full erasure Keep the push button P1 pushed for 2 sec until R1 switches on Release and push P1 again until R3 and R4 flash three times simultaneously A ATTENTION At the end of the procedure all data of the memory are deleted va R1 switches off RED GREEN E ae yhy X v4 eon R1 lits R3 and R4 flash three times simultaneously Keep the push button P1 release Push P1 again until R1 pushed for 2 sec until R1 P1 switches off switches on Fig 15 p es r o er iE RON THESMART LIVING 3 CONNESSIONI fr COM PRI PR2 12 Vac dc 5mo a PR3 sa PR4 ov whe 1 2 3 4 5 6 7 8 9 10 11 12 E ON R1 R2 R3 R4 O 000o e iii STEP P1 PULSE 13 14 15 16 17 18 19 20 21 22 23 24 Fig 1 K1 K2 K3 K4 XN Relay outputs map Relay Terminal Contact Relay Terminal Contact Relay 1 13 NO Relay 3 19 NO Relay 1 14 C Relay 3 20 C Tob 1 Relay 1 15 NC Rel
7. n of the remote controls can be carried on in self learning The transmitter security codes are stored in a non volatile memory EEPROM 2 TECHNICAL SPECIFICATIONS Receiver Yprema aane e aea R EEEE EEEE ES Superheterodyne Carrier frequency cccecceeccesseesseeseeeeesseceeeeeeeeeeseessteneeeeeenees 433 92 MHz Local oscillator frequency 6 6128 MHz Intermediate frequency ccceseceeeceeseeeeeeeseeneeeeeeeteeeeeneteneeeseees 10 7 MHz DemoOdulatiomisices ccis sccacacsiescodecnies Soadsioavasabioalwide aSa AEE E RR AM ASK Sensitivity for good signal Power SUPP Vis sae rearea a E E E NE oes 12 Vac dc Current consumption 250 mA 12 Vac ee See eee eee 120 mA 12 Vdc Output relay number 4 Max power on relay CONTACHS 0 seeceeeseeesseeeeeetsteeesteeenteeenses 3 5 KW 230 Vac Security coding Keeloq Hopping code MEMORY serores genein o Ea EEA ER aces oes 85 transmitter keys 20 70 C 1P2X DIN 4 modules 70 x 90 x 60 8 MODE PULSE STEP Each relay can be set in pulse or step mode according to the set up of the dip switch S1 as shown on the following tab 2 In step or bistable mode the led corresponding to the relay activated blinks R1 R2 R3 R4 DIP SWITCH S1 i i K ON OFF RELAY1 BISTABLE PULSE BISTABLE PULSE Tab 2 ON RELAY2 I I I I RELAY3 BISTABLE PULSE OFF RELAY4 BISTABLE PULSE 9 DISPLAY OF THE MEMORY SPACE With