Home

USER MANUAL AND INSTALLATION GUIDE

image

Contents

1. Mero ERROR 90 DEVIATION MN TARGET SPEED NEXT TACK HEADING meme ILI CMG OPTIMUM X ANGLE TT ee VMG OPTIMUM X ANGLE n ke 6 33 60 059 002 Box WI FI user manual MARINE ELECTRONICS TARGET VMG CURRENT DIRECTION CURRENT SPEED CEE EEE EEE EEE EEE EEE EEE 4 WI FI CONNECTION The WiFi transmits the AIS data and the NMEA sentences coming from the NMEA input as well as the NMEA data from the Topline bus It can also forward NMEA data I e bearing and distance to waypoint to the Topline bus providing the relevant channels are available and to the NMEA output The Box Wi Fi creates a wireless access point 802 11b g with the following parameters e 5510 NKE xxxxxx WPA 21xxxxxxxxxxx matching the serial number featured on the WiFi Box label sticked on the side of the box e address 192 168 56 1 e Port 50000 e CP UDP protocol TCP is a communication protocol which is based on connection with delivery validation and limits the use to one only host while UDP uses a simple transmission model allowing communication with several hosts simultaneously A DHCP server can connect up to 7 hosts simultaneously Data transmitted in NMEA 0183 format is identical to the data output via the wire interface see 83
2. 13 10 TECHNICAL SPECIFICATIONS 15 11 DIAGRAMME DE 16 2 33 60 059 002 Box WI FI user manual MARINE ELECTRONICS 1 INTRODUCTION The nke Wifi Box is a NMEA Topline multiplexer which allows the Topline Bus and NMEA instruments to connect to a PC or any wireless compatible device The Wifi Box features a 0183 wired and wireless input to receive AIS data or any other data coming from a 0183 source It is a communication bridge that converts NMEA data to Topline channels to make information available to display on your Topline system repeaters Gyropilot The Wifi Box also features 0183 wired and wireless output multiplexing Topline and NMEA data for interfacing with a PC or any wireless compatible device 2 NMEA INPUT The nke Wifi Box can process NMEA data format through the wire input and or Wifi wireless connection The nke Box Wi Fi identifies the sentences coming from an AIS receiver or any NMEA 183 source An auto baud rate detection algorithm allows reception of AIS and NMEA data at 4800 9600 19200 or 38400 bauds The baud rate is saved in the memory once 10 correct NMEA sentences have been received The AIS data flow received via the NMEA input is sent directly to the Wifi connection and the NMEA 183 output Data coming from the NMEA 183 device is sent once the set up procedure has been co
3. 5 SET UP FROM A MULTIGRAPHIC DISPLAY If your nke Wifi Box is connected to a Topline Bus featuring a Multigraphic from V2 0 the SSID and WiFi channel can be modified n ke 7 33 60 059 002 Box WI FI user manual MARINE ELECTRONICS Modification of the SSID from Multigraphic External devices Topline devices Topline devices nc eco ETE graphic Display 1 v2 0 Topline devices Multigraphic Display 1 v2 0 A 0 0 Y Topline devices Reading 192 168 56 1 4 0 Y Modification of the WiFi channel from a Multigraphic A selection is offered between Auto and 13 channels The default setting is Auto automatic 8 33 60 059 002 Box WI FI user manual MARINE ELECTRONICS 6 STATUS INDICATORS 4 Status indicators 5 status indicators show the operation status of the Box Wi Fi Init Press the Init key Key press acknowledgement audible signal Fi transmit data coming in the NMEA port Flashes after each valid NMEA sentence received Flashes after each non valid NMEA sentence received NMEA Flashes after each valid NMEA sentence sent on the wired NMEA port TOPLINE Flashes quickly if its Topline address is lt gt 0 Flashes quickly if its Topline address is 0 Fix light data bus Topline wire is disconnected or no mast
4. Environment IP54 protection against dust and water splashing Storage temperature 20 C to 60 C Operating temperature 10 C to 50 C 5 5mm 4 wires ground 3m long nke 15 33 60 059 002 Box WI FI user manual MARINE ELECTRONICS 11 DIAGRAMME DE FLUX Wifi INPUT NMEA OUTPUT NMEA N Init Topline NMEA oudo BOX Wifi Topline Bus Connection examples 1 want to use a single input port on my PC to receive data from the AIS and the Topline send AIS data to the NMEA input with default setup The Wifi Box is connected to the Topline system Both AIS and Topline data will be available from the NMEA wired output in NMEA format 2 want to receive Topline and AIS data on my tablet PC send AIS data to the NMEA input with default setup The Wifi Box is connected to the Topline system Both AIS and Topline data will be available from the WiFi output in NMEA format refer to S9 for WiFi connections 3 want to connect my tablet to a system configured in the same way as in case 1 and use the WiFi in out set up the WiFi connection on my tablet refer to S9 for WiFi connection from my tablet select the data to display and then initialise the NMEA input on the WiFi Box press and hold INI key for 3 seconds refer to S8 4 have a Maxsea application on my PC with a wired connection to the WiFi Box and want to use Adrena to send Performance channels
5. NMEA output ____ NMEA input NMEA input setup WARNING The data coming from an AIS receiver does not need NMEA input calibration It will be directly echoed on the Wi Fi and wired NMEA outputs The NMEA input must be set up to identify and save the NMEA sentences received from the connected instruments GPS PC etc NMEA channels are created and nke _ MARINE ELECTRONICS 12 33 60 059 002 Box WI FI user manual saved in the nke Box Wi Fi memory They will remain on the Topline bus each time the system is turned on Setup procedure e Ensure that the NMEA 183 connected instrument sends data and press INIT until you hear 3 beeps e The NMEA 183 input port will scan for NMEA 183 data This is acknowledged by audible signals over 10 seconds and a long signal once the scan is completed e Once the scan search is completed the unit will sound one signal per channel which has been created on the Topline bus WARNING If there is no NMEA data coming in this procedure gives a slave address to the nke Box Wi Fi In this case the Interface is considered as a slave unit by the master display 9 SET A WIFI CONNECTION TO A SMARTPHONE Connect the device to the WiFi Box network and use the data coming from your Topline bus Activate the WiFi function on your Smartphone VAIO IX29NB WP ibl Wifi ADMINI Wifi_Fab FreeWifi Livebox 38CE Livebox 3
6. connect my PC to the WiFi refer to S9 for WiFi connection to set up ADRENA UDP link IN OUT port 5000 and then initialisethe NMEA input of the WiFi Box press and hold INI key for 6 seconds refer to S7 nke 16 33 60 059 002 Box WI FI user manual MARINE ELECTRONICS D claration de conformit Nous Nke marine electronics rue Gutenberg 2 de Kerandr 56700 HENNEBONT Tel 33 297 365 685 Fax 33 297 364 674 D clarons sous notre seule responsabilit que le produit BOX WiFi Auquel se r f re cette d claration est en conformit avec les sp cifications suivantes Safety EN 60950 1 2006 A11 2009 A1 2010 Health EN 50371 2002 03 EMC EN 301 489 1 V1 8 1 2008 04 EN 301 489 17 V2 1 1 2009 05 Radio EN 300 328 V1 7 1 2006 10 FCC Part 15C FCC id T9J RN171 IC RSS 210 Le produit est conforme aux exigences de la directive 89 336 et porte en cons quence le marquage Hennebont Jean Claude LE BLEIS CET Cet appareil est conforme la partie 15 des r gles de la Son fonctionnement est soumis aux conditions suivantes 1 ce dispositif ne peut pas causer d interf rences nuisibles et 2 cet appareil doit accepter toute interf rence recue y compris les interf rences qui peuvent provoquer un fonctionnement ind sirable C 0681 FE
7. 8CE_EXT 507 66 Scan Wi Fi Direct nke 13 33 60 059 002 Box WI FI user manual MARINE ELECTRONICS select the WiFi Box network see SSID indicated on the WiFi Box label through the list of available WiFi wi Fi VAIO IX29NB Wifi_ADMIN1 Wifi_Fab FreeWifi 38 Livebox 38CE EXT NKE 507A66 Scan Wi Fi Direct Type in the password WPA indicated on the WiFi Box label and press Connect Show password Show advanced options VLLL FL rI 1 3 Advanced settings set the application you want to use nke Display in this ss saath in example with the WiFi Box address 192 168 56 1 Port 50000 and the protocol UDP or TCP Protocol UDP Automatic connection v Automatic connection at launch Timeout seconds 60 nke 14 33 60 059 002 Box WI FI user manual MARINE ELECTRONICS WARNING If your device is using a firewall check and make sure Port 50000 is available 10 TECHNICAL SPECIFICATIONS NMEA input NMEA 183 automatic baud rate configuration from 4800 to 38400 bauds Direct reading of AIS data without input setup NMEA wired output 0183 38400 bauds can be set up with the Toplink utility software at 4800 9600 19200 57600 bauds Wi Fi connection Wi Fi 802 11b g SSID NKE xxxxxx IP address 192 168 56 1 Port 50000 Protocol UDP
8. BOX Wi Fi Product part number 90 60 508 002 USER MANUAL AND INSTALLATION GUIDE nn Zi Kerandr Rue Gutemberg 56700 HENNEBONT FRANCE MARINE ELECTRONICS 32 207 365 685 EE 5 16 01 2 3 2 ee 3 WIRED NMEA OUTPUT mea ae eat na 5 4 WNWIFLOCONNECTION 7 5 PARAMETRAGE AVEC 7 6 STATUS INDICATORS ee 9 7 USING THE INIT 2 9 eee ee 11 11 BEFORE TNSEABEATION __ OMNIUM 11 MOUNTING THE 11 CONNECTION TO THE TOPLINE 5 11 NMEAINPUT SETUP osc cet a 12 _______ _ _____ _ _6_ __ 13 9 SET A WIFI CONNECTION A SMARTPHONE
9. er Flashes every second interface s address is 0 and data bus Topline wire is disconnected or no master 7 USING THE INIT KEY e Press and hold 1 sec to display the number of connected devices up to 5 1 device is indicated by the Topline led lighting red 2 devices by the Topline and NMEA Out 3 devices by the Topline NMEA Out 9 33 60 059 002 Box WI FI user manual MARINE ELECTRONICS NMEA In 4 devices by Topline NMEA Out NMEA In Wifi and 5 devices by all led indicators in red e Press and hold 3 sec followed by OFF and ON to reset all NMEA interfaces Press and hold sec will initialise the NMEA input wire and WiFi listen to NMEA sentences for 10 seconds and then create list and nodes for the Topline bus only slave e Press and hold 6 sec will launch a second NMEA initialisation and add channels without overwriting the existing table With this function you can add NMEA channels coming from the WiFi connection without editing the configuration of the wired NMEA input e Press and hold 9 sec to perform a full reset and return to factory settings nke 10 33 60 059 002 Box WI FI user manual MARINE ELECTRONICS 8 INSTALLATION List of accessories TOPLINE junction box with NMEA connection 90 60 41 7 Before installation The Box WIFI is protected from water splashing It must be mounted in a location where there is no risk of
10. mpleted on the Topline bus WARNING Topline channels have priority a NMEA 183 channel is not considered if an equivalent channel is already available on the Topline bus Once the instrument connected to the NMEA 183 input stops transmitting data the last values are displayed for 64 seconds on the Topline screens The NMEA input has priority on the Wifi NMEA connection Created channels NMEA sentences used RL MERE n ke 3 33 60 059 002 Box WI FI user manual MARINE ELECTRONICS RMC C me RE HEN LN lt TOTAL LOG VLW 8 HOURS DAY ZDA RMC DTI ae ee _ _ Iw ne RER BEARING TO WPT True RMB iia 22 BEARING ORIGIN APA PB J C L E w weomwwmaE wk weomwwmaE wk wl wom __ Le ws Ww LE 5 IM EN Ww Ow POLAR SPEED KEP 37 9 m P n ke 4 33 60 059 002 Box WI FI user manual MARINE ELECTRONICS mex qme ewm me wee ren e mws mue omnes mme s EL mer wem 3 WIRED NMEA OUTPUT The NMEA 183 wired output is set to 38400 bauds by default and sends AIS data from the NMEA 183 input and Topline data converted to NMEA sta
11. ndard sentences to instruments from other manufacturers This NMEA output baud rate can be set up to 4800 9600 19200 38400 57600 through the Toplink utility software The following settings are available via function 10 Baudrate NMEA OUT 51712 4800 bauds 51713 9600 bauds 51714 19200 bauds 51715 38400 bauds 51716 57600 bauds The following data is converted and sent via NMEA 183 depending on the relevant sensors being connected to the TOPLINE bus Canaux 2 2 Topline RE ANGLE RENE wear PO d mS _ _ nke MARINE ELECTRONICS 01 02 PNKEP 03 PNKEP 04 PNKEP 05 o 33 60 059 002 Box WI FI user manual m 3 4 T ET 3 E EL I gg Ex ow HEADING mene P _ _ di a MAST ANGLE AE i 9S L TL _ _ TT om LL TL X51 Lg LII LE LI om LL LIS EI LI d dll _ _ _ WATER TEMPERATURE ATMOSPHERIC X PRESSURE BAROMETER COMPASS CAP OVER GROUND SPEED OVER x GROUND OR BEEN HOUR DAY E Li MINSEC 1 rw I omm
12. submersion Mounting the Box WiFi Use 04mm screws NARIN _ WARNING The connection of the nke Box Wi Fi must be carried out before power to the unit is switched on Connection to the Topline Bus Run the nke Box Wi Fi cable to the TOPLINE junction box in your system N Connect the bus cable in the junction box Connect the NMEA and NMEA wires to your NMEA 183 device or AIS receiver nke 11 33 60 059 002 Box WI FI user manual MARINE ELECTRONICS a Power supply 12Vdc prd __ _ MARINE ELECTRONICS mt we nterface _______ Tpi Bus Wire NMEA 183 Output Red wire NMEA 7 m Yellow wire nstrument NMEAor AIS Green wire Tio Topline bus J Interface A DATA black 12VDC white gt 5 xo zog ejg id O 252 6 22 22 Junction box 90 60 417 CONNECTION TO TOPLINE BUS S Should you need to shorten the bus cable uncover and tin the wires before connecting in the junction box Wire colour codes 5 wire white cable Identification E output output

Download Pdf Manuals

image

Related Search

Related Contents

Kenwood KDCBT7043U Car Stereo System User Manual  BUDERUS manuale uso Logamax plus GB032 24K  Carrier 38ETG Instruction manual  スチーム & ウォーター ミキシング・バルブ    Trav-L-Vac 300 User Manual  90748-MSM-Bulletin Novembre  ラピネスシートPW250M  Technicolor - Thomson IB5400GB User's Manual  Válvulas Fisher ED y EAD easy-et CL125 a CL600  

Copyright © All rights reserved.
Failed to retrieve file