1. However a shock from an electric fence pulse is very uncomfortable and animals quickly learn to respect electric fences An electric fence is not only a physical barrier but is also a strong psychological barrier What are the benefits of an electric fence An electric fence has many benefits over conventional fencing Requires less labour and materials to construct Flexibility to change or add paddocks when required The use of strip grazing techniques can allow temporary fencing to be quickly and easily erected or removed Controls a broader range of animals Minimises damage to expensive livestock when compared with other fencing mechanisms for example barbed wire 46 Installation Read all of the safety instructions in this manual carefully before installing the energiser Selecting a site for the installation of the energiser Follow these guidelines when selecting a site for your installation Select a site where e a good earth can be obtained e children and animals cannot interfere with the installation e the energiser can be accessed easily Make sure the energiser is installed e adjacent to the electric fence e preferably in the middle of the electric fence system e close to a mains line power outlet if using the mains power adaptor supplied e at least 1 m 3 away from and not directly above the battery if using a battery to power the energiser If your installation is outside also m
2. addresses from 1 to 15 are available Hold the remote control within 5 to 15 cm of the energiser and press to transmit the new setting to the energiser The new address setting will appear for 2 seconds in the display Press t turn off the remote control 56 Building an Electric Fence Components of an electric fence An electric fence system comprises the following elements e An energiser e An earth system This comprises a number of metal rods inserted into the ground which are connected to the earth terminal on the energiser e Insulated underground cables Used to connect the energiser to the earth and fence e An insulated fence Connected to the Fence terminal of the energiser Fences can be made to a variety of designs see below Note The animal receives a shock when it completes a circuit between the fence and the earth system The fence has all live wires and requires conductive soils Energiser gt gt SE ie D Sie lt Earthretun lt amp Fence designs Fences can be constructed to suit the type of livestock and materials available Discuss with your PATURA distributor which design best suits your needs Permanent electric fencing PATURA offers a range of products that allow the farmer to construct permanent electric fences A professional permanent electric fence allows the farmer to e Fence in big areas fields e Gain ideal conductivity fo
3. Les lignes doivent tre prot g es des endommagements que pourraient occasionner les sabots des animaux ou les pneus des v hicules Enfin les lignes de raccordement ne doivent en aucun cas tre mises dans la m me gaine que les c bles du r seau lectrifi les c bles de communication ou de transfert de donn es Il est interdit d installer les lignes de raccordement et les fils conducteurs des cl tures lectriques au dessus des lignes a riennes de l lectricit ou du t l phone g p 39 Il faut viter autant que possible les croisements avec les lignes a riennes S il est in vitable le croisement doit s effectuer en dessous des lignes lectriques en formant du mieux qu on peut un angle droit Voici les distances minimum respecter si l installation des lignes de raccordement et des fils conducteurs de la cl ture lectrique se fait amp proximit d une ligne a rienne Tension de la ligne lectrique Distance lt 1 000 V 3m gt 1 000 lt 33 000 V Am gt 33 000 V 8m Dans ce m me cas la hauteur de la cl ture ne devra pas d passer 3 m Ce principe s applique aux cl tures lectriques plac es des deux c t s de la projection orthogonale au sol du conducteur de courant plac le plus l ext rieur ce sur une distance d au moins e 2m pour les lignes lectrifi es avec une tension nominale inf rieure ou gale 1 000 V e 15m pour les lignes lectrifi es avec une tension nominale sup rieur
4. P4500 P4600 im Netzbetrieb Mindestens 3 Erdst be 2 m P4500 P4600 im Batteriebetrieb Mindestens 3 Erdst be 1 m Um das Erdungssystem zu berpr fen verfahren Sie wie folgt 1 Schalten Sie das Elektrozaunger t aus 2 Verursachen Sie in einem Abstand von mindestens 100 m vom Elektrozaunger t einen schweren Kurzschluss am Zaun indem Sie mehrere Stahlst be oder Rohre an den Zaun lehnen Die besten Ergebnisse werden erzielt wenn die Zaunspannung dort auf 2000 V oder weniger abgesenkt wird Bei trockenen oder sandigen B den m ssen die Stahlst be m glicherweise bis zu 300 mm tief in den Boden versenkt werden 3 Schalten Sie das Elektrozaunger t wieder ein 16 4 Vergewissern Sie sich mit einem PATURA Digital Voltmeter DVM dass die Zaunspannung unter 2 kV liegt 5 berpr fen Sie Ihr Erdungssystem Stecken Sie den Erdstab des Voltmeters in gewissem Abstand soweit es die Kabell nge erlaubt vom letzten Erdstab in den Boden und halten Sie den Messkontakt an den letzten Erdstab Der Spannungspr fer sollte nicht mehr als 0 5 kV anzeigen Ist die Spannung h her muss die Erdung verbessert werden Bringen Sie in diesem Fall entweder zus tzliche Erdst be an oder suchen Sie f r die bereits verwende ten Erdst be einen besseren Boden Ideal w re eine Spannung unter 0 2 kV Elektrozaunger t Kurzschlu stromf hrend stromf hrend Erdung ea Sicherheitshinwe
5. aucune mesure n cessaire eee D 11 7 12 0V Niveau de charge moyen 20 50 e observez l tat de chargement e chargez la batterie pour emp cher des dommages CO 11 2 11 7 V Niveau de charge faible 10 20 e chargez de suite la batterie e le poste passe automatiquement en mode impulsions lentes et demi puissance mn gt 11 2V Niveau de charge tr s faible 0 20 e chargez de suite la batterie e le poste s teint automatiquement protection contre d charge profonde La derni re lampe verte clignote une fois par seconde Note e En cas de temp ratures extr mes les tats de charges mentionn s peuvent varier e Apr s 30 secondes l affichage digitale remontre la tension cl ture 31 Seulement P4600 Si l tat de charge de la batterie est faible le symbole batterie clignote deux fois par seconde Nous conseillons alors de recharger imm diatement la batterie Symbole batterie S lection et maniement de la batterie La pr sente section se r f re exclusivement des batteries acide plomb rechargeables par exemple aux batteries de tracteur de camion aux batteries marines ou aux batteries sp ciales cl ture d charge lente La taille de la batterie que vous choisirez d pendra du mod le de votre lectrificateur et du r glage de la fr quence des impulsions que vous utiliserez le plus fr quemment Reportez vous Utilisation eu page 29 pour trouver une description des r gla
6. tension et voltage e d tecteur de pertes aide localiser les pertes tout endroit du syst me de cl ture Pour plus d information veuillez lire le manuel de la t l commande Attention apr s une coupure de courant le poste se remet en marche automatiquement Cela est aussi le cas si le poste t teint auparavant avec la t l commande Pour cela nous vous conseillons durant de longues p riodes de travaux d isoler la partie concern e de la cl ture avec des interrupteurs cl ture ou d brancher le poste Communication entre le poste et la t l commande Le P4600 r agit seulement la t l commande si la t l commande a t activ e auparavant avec le poste Cette mesure est prise en charge par nos soins avant envoi Dans le cas contrare l activation doit tre faite seulement une fois Les deux appareils fonctionnent seulement ensemble s ils ont le m me code Activation fonction t l commande Pour v rifier si la fonction t l commande est activ e 1 Mettez le poste en mode Attendez 5 secondes et mettez le Fl che poste dans le mode souhait a 2 Attendez que l lectrificateur montre la tension de sortie 3 Si une fl che clignote au c t droit de l cran la fonction t l commande n est pas activ e 4 Si la fl che s affiche en permanence la fonction est activ e 34 Pour activer la fonction La fonction peut tre activ e seulement dans les 10 premi res mi
7. above the ground shall not exceed 3 m 10 This height applies to either side of the orthogonal projection of the outermost conductors of the power line on the ground surface for a distance of 60 e 2 m 7 for power lines operating at a nominal voltage not exceeding 1 000 V e 15 m 50 for power lines operating at a nominal voltage exceeding 1 000 V Energisers connected to electric fences shall not be installed in buildings with fire risk like barns storage sheds or stables To prevent lightning damages you have to install lightning protection spark gap with earthing in the leadout cable before you run it inside the building Electric fences intended for deterring birds household pet containment or training animals such as cows need only be supplied from low output energisers to obtain satisfactory and safe performance In electric fences intended for deterring birds from roosting on buildings no electric fence wire shall be connected to the energiser earth stake A warning sign shall be fitted to every point where persons may gain ready access to the conductors Where an electric fence crosses a public pathway a non electrified gate shall be incorporated in the electric fence at that point or a crossing by means of stiles shall be provided At any such crossing the adjacent electrified wires shall carry warning signs Any part of an electric fence that is installed along a public road or pathway shall be identified at freque
8. animals or for the purpose of security comprising one or more conductors such as metal wires rods or rails Electric fence A barrier which includes one or more electric conductors insulated from earth to which electric pulses are applied by an energiser Fence circuit All conductive parts or components within an energiser that are connected or are intended to be connected galvanically to the output terminals Earth stake Metal structure that is driven into the ground near an energiser and connected electrically to the Earth terminal of the energiser and that is independent of other earthing arrangements Connecting lead An electric conductor used to connect the energiser to the electric fence or the earth stake Electric animal fence An electric fence used to contain animals within or exclude animals from a particular area Pulsed conductors Conductors which are subjected to high voltage pulses by the energiser Requirements for electric fences Electric fences and their ancillary equipment shall be installed operated and maintained in a manner that minimises danger to persons animals or their surroundings Electric fence constructions that are likely to lead to the entanglement of animals or persons shall be avoided WARNING Avoid contacting electric fence wires especially with the head neck or torso Do not climb over through or under a multi wire electric fence Use a gate or a specially designed crossing point Th
9. hrenden Zaun mit Stacheldraht oder scharfkantigem Draht erg nzt werden Die St tzvorrichtungen der stromf hrenden Dr hte sind so auszulegen dass zwischen den stromf hrenden Dr hten und der vertikalen Ebene der nicht stromf hrenden Dr hte ein Mindestabstand von 15 cm gew hrleistet ist Der Stacheldraht und der scharfkantige Draht sind in regelm igen Abst nden zu erden Wir empfehlen aus Sicherheitsgr nden bei diesen Z unen mit Abstandsisolatoren nur Ger te unter 5 Joule Impulsenergie zu verwenden Befolgen Sie unsere Erdungsempfehlungen Siehe Installation und berpr fung eines Erdungssystems Zwischen den Erdst ben des Elektrozaunger ts und m glichen anderen Komponenten die an ein Erdungssystem angeschlossen sind wie beispielsweise der Schutzerdung der Stromversor gung oder der Erdung des Telefonnetzes ist ein Mindestabstand von 10 m einzuhalten In Geb uden verlaufende Anschlussleitungen sind wirksam von den geerdeten Bauelementen des Geb udes zu isolieren Zu diesem Zweck k nnen isolierte Hochspannungskabel verwendet werden Unterirdische Anschlussleitungen sind in einem Isolierrohr zu verlegen Alternativ dazu k nnen 18 isolierte Hochspannungskabel verwendet werden Die Anschlussleitungen sind vor Besch digung durch in den Boden einsinkende Tierhufe oder Fahrzeugreifen zu sch tzen Anschlussleitungen d rfen nicht zusammen mit Netzstrom Kommunikations oder Datenkabeln im selben Rohr verlegt werden Anschlu
10. indem sie die Spannung am Erdungssystem mit der Spannung auf einem separaten Erdstab vergleicht Stellen Sie sicher dass der separate Erdstab mindestens 10 m von jedem anderen Erdungssystem inklusive der Haupterdung des Elektrozaunger tes entfernt ist Schlagen dazu einen mindestens 1 m langen Erdstab in den Boden Benutzen Sie hochspannungsfestes Kabel zur Verbindung des Erdungs berwachnungsanschlusses mit dem separaten Erdstab Achten Sie auf guten Kontakt und geschraubte Verbindungen Kontrolle der Erdung Wenn die erste Kontrolllampe dauerhaft aufleuchtet und die Erdungsanzeige im Display kleine Ziffern oben rechts zweimal in der Sekunde blinkt deutet dies darauf hin dass die Erdspannung ber 0 8 kV liegt und eine Verbesserung der Erdung zu empfehlen w re Zur Verbesserung der Erdung f gen Sie weitere oder l ngere Erdst be hinzu Die Erdspannungsanzeige zeigt die Spannung auf den Erdst ben an wenn der Schalter auf den Positionen w mw oder steht Die Erdspannung sollte immer unter 0 8 kV liegen Wenn die Erdspannung ber 3 0 kV liegt blinkt die Anzeige um anzuzeigen dass die Erdspannung ungen gend ist Erdspannung Batterietest Einstellung Wenn das Elektrozaunger t mit einer Batterie verbunden ist und der Schalter auf der Stellung Batterietest steht zeigen die Kontrolllampen den Ladezustand der Batterie an Die Batterietest Einstellung ist nur relevant wenn das Ger t mit einer Nassbatterie verbunde
11. public en y apposant des panneaux de signalisation intervalles rapproch s Ces panneaux doivent tre accroch s solidement aux poteaux ou aux fils conducteurs de la cl ture e Les panneaux de signalisation doivent mesurer un minimum de 100 x 200 mm e Ils doivent porter sur un fond de couleur jaune appliqu sur les deux faces la mention cl ture lectrique pour animaux en lettres noires ind l biles d au moins 25 mm de hauteur ou un symbole du type ci contre Tous les accessoires reli s au secteur qui seront connect s amp la cl ture lec trique entre le circuit de la cl ture et l alimentation r seau doivent tre isol s 40 aussi efficacement que l lectrificateur lui m me Les accessoires sont prot ger des intemp ries moins que le fabricant indique express ment qu ils sont con us pour usage en ext rieur avec un degr de protection d un minimum de IPX4 Questions fr quemment pos es R ponses Quelle est la tension requise pour la surveillance des animaux Il est recommand d utiliser une tension de 4 kV minimum pour contenir les animaux Mais le syst me de construction de la cl ture est tout aussi important pour emp cher que les animaux passent entre les fils de la cl ture La tension de la d ture est inf rieure 4 KV Comment l augmenter Verifiez votre lectrificateur Assurez vous qu il ne soit pas r gl sur le mode demi puissance D connectez l lectrificateur du sy
12. recharge a non rechargeable battery e When recharging a battery ensure that there is adequate ventilation to allow gases to disperse Regular recharging of the battery is essential Use a suitably rated battery charger and refer to the battery manufacturer s recommendations 1 Disconnect the battery from the energiser 2 Attach the positive battery charger lead to the positive terminal of the battery and the negative battery charger lead to the negative terminal on the battery 3 Insert the battery charger s input power plug into a mains or line socket and turn on the power supply 4 After the battery is charged disconnect it from the battery charger before connecting it fo the energiser Caution Overcharging the battery will reduce its life Do not exceed the recommendations of the battery manufacturer on recharging the battery from a mains powered line powered source Battery care and maintenance e House the battery in a suitably designed battery box if the battery is likely to be exposed to the weather e When not in use keep the battery as fully charged as possible e Recharge a discharged battery as soon as possible e Batteries should be stored fully charged and recharged at regular intervals every 8 weeks e Inspect the battery regularly to ensure that the electrolyte level does not fall below 12 mm Y2 above the surface of the battery plates Top up the battery using distilled water Do not overfil
13. rieur en cas d alimentation sur secteur Attention e Ne pas utiliser de rallonge lectrique e Laisser au moins 25 mm d espace libre autour de la prise lectrique Pour installer l lectrificateur l int rieur 1 Choisissez un endroit d installation appropri NS Voir Choisir un endroit d installation la page 27 2 Montez l lectrificateur sur un mur Si n cessaire mm cart utilisez le gabarit imprim sur la couverture arri re du pr sent manuel C ble haute 3 Reliez la borne de terre de la cl ture verte tension isol au syst me de mise la terre 4 Pour le P4600 si souhait vous pouvez brancher la borne contr le de prise de terre noire avec un piquet de terre s par Pour plus de d tails voir page 30 Contr le de la prise de terre 5 Connectez la borne pleine tension rouge ou demi tension jaune la cl ture 6 Branchez le poste sur le r seau lectrique l aide de l adaptateur secteur Note Si l electrificateur est install l int rieur il peut si n cessaire tre aliment sur batterie au lieu de l alimentation sur secteur Installation l ext rieur L lectrificateur peut tre install l ext rieur et aliment sur batterie Attention Ne pas brancher l lectrificateur au r seau lectrique s il est install l ext rieur Pour installer lectrificateur l ext rieur 1 Choisissez un end
14. s mtliche netzbetriebenen Zusatzger te die an den elektrischen Weidezaun angeschlossen werden zwischen dem Zaunkreislauf und der Netzversorgung ebenso stark isoliert sind wie das Elektrozaunger t selbst Zusatzger te sind vor Witterungseinfl ssen zu sch tzen es sei denn sie sind vom Hersteller f r die Verwendung im Freien ausgewiesen und haben eine IP Schutz von mindestens IPX4 H ufige Fragen und Probleml sungen Welche Spannung ist f r die Kontrolle der Tiere erforderlich 4 KV ist die allgemein anerkannte Mindestempfehlung f r das H ten von Tieren Allerdings brauchen Sie auch ein gut gebautes Zaunsystem um sicherzustellen dass die Tiere nicht durch die stromf hrenden Dr hte schl pfen k nnen Die Zaunspannung liegt unter 4 kV Wie kann ich die Spannung erh hen berpr fen Sie das Elektrozaunger t Vergewissern Sie sich dass das Elektrozaunger t auf volle Leistung gestellt ist Trennen Sie das Elektrozaunger t vom Zaunsystem ab Messen Sie mit Hilfe eines PATURA Zaun Kompasses Digital Voltmeters oder Zaunpr fer die Spannung an den Klemmen des Elektrozaunger ts Betr gt die Spannung weniger als 6 kV lassen Sie Ihr Ger t von Ihrem PATURA Kundendienst berpr fen berpr fen Sie die Erdung des Elektrozaunger ts Beim P4600 berpr fen Sie dass die Erdspannung auf der Digitalanzeige unter 0 8 kV liegt siehe auch Erdungskontrolle Seite 9 F r das P4500 verfahren Sie gem der Anleitung unter Installation u
15. service agent to check the energiser The energiser does not respond to commands from the Remote Control Handset Ensure you have a P4600 The P4500 does not respond to commands from a remote control handset Ensure that the remote contact on the Remote Control Handset is in contact with the fence wire before pressing or Holding the button down for an extended period will not make the remote control work better After pressing or X wait for two seconds for the ON or OFF message to disappear from the display as the energiser may send out a final pulse after receiving the command to deactivate Similarly allow two seconds for the energiser to send out its first pulse after receiving the command to reactivate If the battery symbol is displayed on the Remote Control Handset replace the 9 V alkaline battery and try again Rusty or oxidised wire can hamper the quality of the signal you receive To obtain a clear signal rub the Remote contact against the fence wire to break through the layer of rust or oxidation 62 Ensure that no gates or cut out switches have been left open Sometimes the remote control will work in spite of minor breaks in the wire although reliable operation under such conditions is not guaranteed Check for spark gaps and loose wire joints in the fence Severe or multiple spark gaps reduce the effectiveness of the remote control Use the fault finding function of the remote control
16. t verhindert das unbeabsichtigte Ein bzw Ausschalten von Z unen Bei neuen Ger ten ist die Voreinstellung f r die Adresse auf 1 eins eingestellt Hinweis Die Fernbedienungsfunktion kann nur innerhalb der ersten 10 Minuten nach Einschalten des Ger tes ge ndert werden ndern der Adresse f r die Fernbedienung 1 Schalten Sie das Ger t mit dem Schalter auf Warten Sie 5 Sekunden dann schalten Sie das Ger t wieder auf einer beliebigen Position ein 2 Dr cken Sie um die Fernbedienung einzuschalten 3 Halten Sie die Fernbedienung im Abstand von 5 bis 15 cm vor das Ger t und dr cken Sie Das Ger t h rt auf zu schlagen und im oberen Teil des Displays wird das Wort OFF angezeigt 4 Dr cken Sie um die Fernbedienung auszuschalten 5 Dr cken Sie und halten Sie gedr ckt und dr cken dann um die Fernbedienung einzuschalten Die Fernbedienung ist jetzt im Einstellungsmodus 6 Dr cken Sie wiederholt bis AD in der Anzeige erscheint 14 7 Dr cken Sie und halten Sie bis die gew nschte Adresse erscheint Adressen zwischen 1 und 15 stehen zur Verf gung 8 Halten Sie die Fernbedienung im Abstand von 5 bis 15 cm vor das Ger t und dr cken Sie Die Fernbedienung bertr gt jetzt die neuen Adresseinstellungen zum Ger t Das Ger t zeigt die neuen Adresseinstellungen f r 2 Sekunden im Display 9 Dr cken Sie um die Fernbedienung auszuschalten Errichtung eines Elektrozauns Bestand
17. the fence is live Lights Input supply voltage Battery charge level M Above 17 0 V Battery overcharged or wrong type of battery 00000000 126 170V Excellent battery charge level 80 100 e No action required 12 3 12 6 V Very good battery charge level 50 80 12 0 12 3 V e No action required QII 11 7 12 0V Low battery charge level 20 50 e Monitor battery level Recharge the battery to avoid long term damage to the battery 11 7V Poor battery charge level 10 20 e Recharge the battery immediately e Energiser will automatically revert to Slow Speed and Half Power fe N Below 11 2 V Very poor battery charge level 0 20 e Recharge the battery immediately e Energiser will automatically shutdown deep discharge protection to save energy The last green LED flashes once per second fa 52 Notes e In extreme temperatures these guidelines may not apply After 30 seconds the display will switch from the battery test results to the fence voltage P4600 only When the voltage is outside the normal range the battery symbol in the display flashes twice per second We recommend to recharge the battery immediately Battery symbol Battery selection and management This section refers exclusively to rechargeable lead acid batteries for example car tractor truck marine or specialist deep cycle batteries The size of battery you select will depend on the m
18. to locate faults in the fence line Check all connections to the fence and the earth system Ensure that the energiser is connected to the power supply and the fence system and that the energiser is switched on Try turning the energiser on and off by holding the Remote contact against the leadout wire or by holding the remote control close to the energiser within 15 to 30 cm pressing the respective button If the energiser still does not respond then the remote control and energiser may have different address settings See Changing the address setting of the remote control handset on page 56 and Activating the remote control function page 55 want to disable the remote control feature If you have a remote control handset see the remote control handset s user manual If not take the energiser to an authorised dealer to have the feature disabled The energiser sometimes turns off unexpectedly e An adjacent property may have an energiser operating at the same address setting See Changing the address setting of a remote control handset page 56 If the problem per sists seek advice from your PATURA dealer Identifying Faults The output voltage digits The fence voltage is too low There could be a serious fault large digits on the LCD on the fence line See How do locate faults in Frequently display flash twice per second asked questions Troubleshooting on page 61 The first red Indicator light is The eart
19. une batterie d charg e aussi t t que possible e Les batteries doivent tre gard es dans un tat charg plein et recharg es des intervalles r guliers toutes les 8 semaines e Contr lez la batterie r guli rement pour vous assurer que le niveau de remplissage en acide ne tombe pas en dessous de 12 mm au dessus de la surface des plaques de batteries Pour augmenter le niveau de l acide utiliser exclusivement de l eau distill e Remplir la batterie ras bord sans qu elle d borde Pour plus d informations consultez les recommandations du fabricant de la batterie 33 S curit de batterie e La batterie doit tre bien a r e lors de la recharge e vitez des temp ratures sup rieures 50 C e vitez une exposition de la batterie aux flammes et aux tincelles Utilisation de la t l commande seulement P4600 Attention le P4500 ne peut pas tre teint avec une t l commande Le P4600 est pr par pour recevoir les signaux de la t l commande Aucune pr paration est n cessaire L lectrificateur et la t l commande sont programm s pour communiquer ensemble La t l commande avec d tecteur de pertes int gr comprend en fait 3 appareils en un Elle sert de e t l commande capable de mettre en marche ou d arr ter lectrificateur de n importe quel endroit de la cl ture e voltm tre amp rem tre livre des informations en temps r el sur la puissance de la cl ture
20. unter Ziffern blinkt 2x pro Sekunde H ufige Fragen und Probleml sungen Seite 20 Die erste rote Lampe leuch Die Erdspannung ist zu hoch Benutzen Sie die tet permanent und die Erdungskontrollfunktion um die Erdung zu berpr fen Siehe Erdspannungsanzeige kleine Erdungskontrolle Seite 9 Ziffern blinkt 2x pro Sekunde Das Batteriesymbol im Die Batteriespannung ist zu niedrig berpr fen Sie sofort Display blinkt 2x pro die Batteriespannung mit der Batterietest Funktion Siehe Sekunde Batterietest Einstellung Seite 10 Die Pfeil rechts im Display Das Ger t sucht nach einer Fernbedienung Dies geschieht blinkt zweimal pro Sekunde immer innerhalb der ersten 10 Minuten nachdem das Ger t eingeschaltet wird und die Fernbedienungsfunktion im ger t noch nicht aktiviert wurde Dies geh rt zum normalen Betrieb Das Ger t arbeitet nicht Die Batteriespannung ist so niedrig dass das Ger t nicht mehr und das letzte gr ne Licht arbeiten kann blinkt einmal pro Sekunde ODER P4600 Das Ger t wurde ber die Fernbedienung ausgeschaltet Das Ger t arbeitet nicht Die Verbindung mit der Batterie erscheint fehlerhaft und das erste rote Licht berpr fen Sie alle Batterieverbindungen berpr fen Sie blinkt zweimal pro Sekunde sofort die Batteriespannung mit der Batterietest Funktion Siehe Batterietest Einstellung Seite 10 22 Wartung Das Elektrozaunger t ist schutzisoliert d h anstelle einer Erdung werden
21. will appear in the top part of the display The arrow on the right of the display will stop flashing and remains continuously lit Changing the Address setting You may want to change the address setting of your energiser e If you are using more than one remote controlled energiser on your property and you want each remote control to operate one energiser only e IF an adjacent property has an energiser that is operating at the same address setting e If your energiser turn off unexpectedly quite often Different address settings for each energiser prevents unintentional activation or deactivation of fence lines The address setting of new energisers is 1 one Note The remote control feature can only be changed during the first 10 minutes of operation Changing the address setting of the remote control handset 1 Move the switch of the energiser to O Wait 5 seconds and switch it back on to the desired position Press to turn on the remote control handset Hold the remote control handset within 5 1015 cm of the energiser and press The energiser will stop pulsing and the word OFF will appear in the top part of the display Press to turn off the remote control handset Press and hold and then press to turn on the remote control handset The remote control is now in the address setting mode Press repeatedly until AD is shown on the display Press and hold until the address setting you want is displayed
22. Anleitung gr ndlich lesen Sie enth lt wichtige Sicherheitsinformationen und hilft Ihnen daf r zu sorgen dass Ihr Elektrozaun zuverl ssig optimale Leistung bringt Wichtige Sicherheitshinweise e Schalten Sie das Elektrozaunger t aus bevor Sie Arbeiten am Ger t oder Zaun durchf hren e Lesen Sie die Sicherheitshinweise sorgf ltig Siehe Sicherheitshinweise Seite 17 e berpr fen Sie bei der Installation dass Sie alle nationalen Vorschriften einhalten e Schlie en Sie das Ger t nicht gleichzeitig an einen Zaun und andere Verbraucher wie zum Beispiel einen Kuhtrainer an Ein Blitzeinschlag in den Zaun wird dadurch an alle weiteren Verbraucher weitergeleitet e Verwenden Sie ausschlie lich das gelieferte Netzteil bzw Batteriekabel bzw Original Ersatzteile Hinweis Dieses Produkt ist gedacht zur Verwendung mit Elektroz unen zur Kontrolle von Tieren Teile Ihres Elektrozaunger tes _ Kontroll anzeigen Anschluss buchse gt Stromversorgung anzeige nur P4600 Schalter f Erdungs Erdungs Zaun Zaun anschluss kontroll anschluss anschluss gr n anschluss halbe volle schwarz Spannung Spannung nur P4600 gelb rot Erl uterung der Symbole die auf dem Elektrozaunger t abgebildet sind Erdungsanschluss Verbinden Sie diesen Anschluss mit Ihrem Erdungssystem Erdungskontrollanschluss nur P4600 Verbinden Sie diesen Anschluss mit einem separaten Erdungsstab siehe Erdung
23. P4500 verarbeitet keine Befehle von einer Fernbedienung e Stellen Sie sicher dass der Schaltkontakt auf der Fernbedienung oberer spitzer Kontaktstift fest an den Zaundraht gedr ckt ist bevor Sie die oder Taste dr cken Ein l n geres Dr cken der Taster verbessert nicht die Wirksamkeit der Fernabschaltung Nach dr cken der oder Taste warten Sie f r 2 Sekunden bis der ON oder OFF Hinweis im Display verschwindet da das Elektrozaunger t vielleicht noch einen letzten Impuls abgibt nachdem es das Signal zum Abschalten erhalten hat Warten Sie ebenso f r 2 Sekunden bis das Ger t seinen ersten Impuls abgeben kann nachdem es das Signal zum Einschalten erhalten hat e Wenn das Batteriesymbol auf der Fernbedienung angezeigt wird ersetzen Sie die 9 V Batterie e Rostiger oder oxidierter Draht kann die Qualit t des Schaltsignals der Fernbedienung beein tr chtigen Um ein gutes Signal zu bekommen reiben Sie mit dem spitzen Kontakt an der Fernbedienung fest gegen den Zaundraht um die Rost oder Oxidschicht zu durchbrechen e Vergewissern Sie sich dass keine Tore bzw Zaunschalter offen gelassen wurden e Manchmal arbeitet die Fernbedienung trotz kleiner Unterbrechungen im Zaundraht obwohl eine zuverl ssige Funktion unter solchen Bedingungen nicht gew hrleistet ist e Kontrollieren Sie Ihren Zaun auf Funkenspr nge und lose Drahtverbindungen Starke oder mehrere Funken berspr nge reduzieren die Effektivit t des Fer
24. Wenn der Pfeil rechts im Display dauerhaft angezeigt wird ist die Fernbedienungsfunktion aktiviert P Piil Um die Fernbedienungsfunktion im Ger t zu aktivieren Hinweis Die Fernbedienungsfunktion kann nur innerhalb der ersten 10 Minuten nach Einschalten des Ger tes aktiviert werden 1 Vergewissern Sie sich dass die Adresse in der Fernbedienung auf 1 eingestellt ist Details finden Sie in der Bedienungsanleitung zur Fernbedienung 2 Schalten Sie das Ger t mit dem Schalter auf Warten Sie 5 Sekunden dann schalten Sie das Ger t wieder auf einer beliebigen Position ein 3 Warten Sie bis das Ger t die Ausgangsspannung anzeigt 4 Dr cken Sie um die Fernbedienung einzuschalten 5 Halten Sie die Fernbedienung im Abstand von 5 bis 15 cm vor das Ger t und dr cken Sie Das Ger t h rt auf zu schlagen und im oberen Teil des Displays wird das Wort OFF angezeigt Der Pfeil rechts im Display h rt auf zu blinken und leuchtet permanent ndern der Adresseinstellungen Es kann sein dass Sie die Adresseinstellungen des Ger tes ndern wollen e Wenn Sie mehr als ein Weidezaunger t mit Fernbedienung auf Ihrem Betrieb benutzen und wollen dass mit einer Fernbedienung nur jeweils eine Anlage ausgeschaltet werden kann e Wenn auf einer benachbarten Zaunanlage eine Ger t mit gleicher Fernbedienungsadresse benutzt wird e Wenn Ihr Ger t unerwartet ausgeschaltet wurde Der Gebrauch unterschiedlicher Adressen f r jedes Ger
25. a 1 5 Sekunden zwischen 2 Impulsen Volle Leistung Das Ger t arbeitet mit voller Leistung schnelle Impulsfolge und schneller Impulsfolge ca 1 5 Sekunden zwischen 2 Impulsen Ablesen der Spannung Wenn Sie das Ger t an die Stromversorgung anschlie en beginnt das Elektrozaunger t nach 3 Sekunden zu arbeiten Die Kontrolllampen zeigen die Spannung am Ausgangsanschluss f r volle Spannung des Elektrozaunger tes an Jede Lampe entspricht ca 1 kV 1000 Volt Ausgangsspannung Leuchten z B bei jedem Impuls die ersten 8 Lampen auf betr gt die Ausgangsspannung ca 8 kV 8000 Volt Rot Gr n Cc AT 0000000 GDRBDPPDPD w Hinweis Leuchten 10 Lampen auf kann die Ausgangsspannung auch ber 10 kV 10000 Volt liegen Sehen Sie bei jedem Impuls nur rote Lampen und keine gr nen ist Ihr Zaun sehr stark belastet und Sie m ssen nach Fehlern in Ihrem Zaun suchen Siehe H ufige Fragen und Probleml sungen Seite 20 Nur P4600 Wenn das Elektrozaunger t arbeitet zeigen die gro en Ziffern auf dem Display die Ausgangsspannung des Ger tes am Ausgang mit voller Spannung an Ausgangs spannung Hinweis Blinkt die gro e Anzeige 2 mal in der Sekunde weist dies auf eine zu niedrige Zaunspannung hin Es k nnte ein Fehler in Ihrem Zaun vorliegen Siehe H ufige Fragen und Probleml sungen Seite 20 Erdungskontrolle nur P4600 Vorbereitungen zur Erdungs berwachung Die Erdungs berwachung arbeitet
26. ahr f r Menschen Tiere und deren Umfeld so gering wie m glich ist Elektrozaunkonstruktionen bei denen die Gefahr gro ist dass Tiere oder Personen h ngenbleiben sind zu vermeiden WARNHINWEIS Vermeiden Sie den Kontakt mit dem Elektrozaun speziell mit dem Kopf Hals oder Rumpf Klettern Sie nicht ber durch oder unter mehrdr htigen Z unen hindurch Benutzen Sie zum berqueren von Z unen ein Tor oder einen speziell gestallteten bergang Dieses Elektrozaunger t ist nicht f r die Verwendung durch unbeaufsichtigte Kinder oder behinderte Personen bestimmt es sei denn sie werden von einer verantwortlichen Person berwacht um zu gew hrleisten dass sie das Elektrozaunger t sicher benutzen k nnen Kinder m ssen berwacht werden um sicherzugehen dass sie nicht mit dem Elektrozaunger t spielen Ein elektrischer Weidezaun darf nicht an zwei oder mehr verschiedene Elektrozaunger te angeschlossen werden Der Abstand zwischen den Dr hten zweier elektrischer Weidez une die von getrennten unabh ngig getakteten Elektrozaunger ten gespeist werden muss mindestens 2 5 m betragen Falls die L cke geschlossen werden soll sind zu diesem Zweck elektrisch nicht leitende Materialien oder eine isolierte Metallabsperrung zu verwenden Stacheldrahtzaun und scharfkantiger Draht d rfen nicht an ein Elektrozaunger t angeschlossen werden Der oder die stromf hrenden Dr hte eines elektrischen Weidezauns k nnen durch einen nicht stromf
27. aille ou m me des piquets suppl mentaires P4500 P4600 branch sur secteur au moins 3 piquets de 2 m P4500 P4600 branch sur batterie au moins 3 piquets de 1 m Vous pourrez v rifier votre prise de terre en proc dant comme suit 1 Arr tez l electrificateur 2 Provoquez une centaine de m tres de distance de l lectrificateur un court circuit en appuyant des piquets en acier ou des tuyaux contre la cl ture Vous obtiendrez de meilleurs r sultats si la tension de la cl ture descend cet endroit 2 000 volts ou moins Si le sol est sec ou sablonneux il faudra peut tre enfoncer les piquets en acier une profondeur de 300 mm dans le sol 3 Remettez l lectrificateur en marche 4 Utilisez le voltm tre num rique PATURA pour vous assurer que la tension de la cl ture est inf rieure 2 kV 37 5 Contr lez votre prise de terre Enfoncez la tige de terre du voltm tre proximit des piquets de terre de l appareil utilisez toute la longueur du c ble du voltm tre et maintenez le contact de mesure du voltm tre sur le dernier piquet Le testeur de tension ne doit pas afficher plus de 0 5 kV Dans le cas contraire il faut am liorer la mise la terre soit en ajoutant des piquets de terre soit en replantant les piquets dans un sol plus appropri La tension est id ale quand elle reste en dessous de 0 2 kV Electrificateur Court circuit gt gt Fil lectrifi Prise
28. ake sure that it is e on firm ground away from flooding e inside a protective fence if required Using the power adaptor and battery leads The energiser is supplied with a power adaptor for connection to mains line power and a set of battery leads for connection to a battery Before connecting a power adaptor or battery leads ensure the energiser selector switch is set to Off To use the power adaptor 1 Connect the power adaptor to the Power input socket on the rear of the energiser Observe the correct polarity 2 Connect the power adaptor to a suitable mains line power socket ensuring there is 25 mm 1 of clear space around the power adaptor To remove the power adaptor 1 Disconnect the power adaptor from the mains line power 2 Carefully pull the plug from the rear of the energiser by wiggling it gently To use the battery leads The battery leads are provided with eyelets which are ideal for a permanent connection to the battery since they ensure good electrical connections In case your battery does not have the connection feature for eyelets or if you move your energiser frequently and desire a quick connection to the battery remove the eyelet from the leads and connect the 47 stainless steel clamps being certain to observe the correct polarity Connect the red eyelet or the red battery clamp to the positive terminal and the black one to the negative terminal of the battery 1 Insert the bat
29. ation A solar installation consists of these items The Energiser Rechargeable battery or battery pack One or more solar panels An earth system For information about the selection of suitable solar panels and batteries please refer to our Electric Fencing Catalogue For detailed installation information please refer to the separate operating instructions supplied with each solar panel For instructions about the installation and monitoring of the earth please refer to Installing and testing an earth system on page 59 49 Operation Pulse speed switch Select the power and speed settings using the switch OFFO 0 poe Sr D Setting Off Full power with battery test Day save mode fast at night Night save mode slow at night Half power fast Full power fast Reading voltage Description The energiser is off and is not operating The P4600 does not respond to the remote control The energiser continues to operate at full power but the Indicator lights show the battery level See Testing the battery voltage on page 53 for an explanation of the Indicator lights The energiser is operating at full power on Fast speed at night pulses every 1 5 seconds and on Slow speed pulses every 2 5 seconds during the day The energiser is operating at full power on Slow speed at night pulses every 2 5 seconds and Fast speed during the day pulses ev
30. battery leads supplied with this energiser or a genuine replacement part Note This product has been designed for use with electric animal fences Parts of the energiser Indicator lt lights _LCD Display _Power input socket Selector switch j Earth Earth monitor Fence Fence terminal terminal half voltage full voltage green black terminal terminal P4600 only yellow red 45 Key to symbols on the energiser Fence earth terminal Connect the fence earth terminal to the earth system Fence earth monitor terminal P4600 only Connect the fence earth monitor ter minal to a separate earth rod see Earth monitoring on page 51 Fence half voltage terminal Connect the fence half voltage terminal to the fence Fence full voltage terminal Connect the fence full voltage terminal to the fence Indicates that to reduce the risk of electric shock the energiser should be opened or repaired only by qualified personnel Sas m I CAUTION Read full instructions before use Recycle this energiser in accordance with the regulations for your country Indicates that the energiser is of a double insulated construction o Dt H How does an electric fence work An electric fence system comprises an energiser and an insulated fence The energiser puts very short pulses of electricity onto the fence line These pulses have a high voltage but are of very short duration less than 3 10 000ths of a second
31. cessary P4500 P4600 mains line operation at least 3 Earth stakes 2 m each P4500 P4600 battery operation at least 3 Earth stakes 1 m each Test the earth system using the following procedure 1 Turn off the energiser 2 At least 100 m 330 away from the energiser short circuit the fence by laying several steel stakes or lengths of pipe against the fence For best results the fence voltage should be lowered to 2 000 V or less In dry or sandy conditions it may be necessary to drive the stakes up to 300 mm 12 into the ground 3 Turn the energiser back on 4 Using a PATURA Digital Voltmeter ensure that the fence voltage is below 2 kV 5 Check your earth system Insert the voltmeter s earth probe into the ground at the full extent of the lead and hold the hook against the last earth stake The tester should not read more than 0 5 kV Anything higher than this indicates that better earthing is required Either add more earth stakes or find a better ground area to drive in the earth stakes A voltage of below 0 2 kV would be best Energiser short circuit gt gt live gt gt N live Earth DVM 58 Safety Considerations Safety considerations according to European Security Standard EN 60335 2 76 Definition of special terms Energiser An appliance that is intended to periodically deliver voltage impulses to a fence connected to it Fence A barrier for
32. cl ture conventionnelle une cl ture lectrique offre de nombreux avantages e Moins de main d uvre et moins de mat riel pour son installation e Adaptation flexible du nombre d enclos selon le besoin Mise en place et d montage rapides et faciles de cl tures temporaires pour la pratique du p turage rationn e Surveillance flexible de diff rentes esp ces d animaux e Minimisation des dommages caus s au b tail par rapport d autres cl tures comme par exemple le fil barbele 26 Installation Veuillez lire attentivement toutes les instructions de s curit du pr sent manuel avant d installer lectrificateur Choisir un endroit d installation Suivez ces instructions pour choisir un endroit d installation S lectionnez un endroit e permettant une bonne mise la terre e tant l abri des enfants et des animaux e offrant un acc s facile l installation Assurez vous que l lectrificateur soit install e a c t d une cl ture lectrique e de pr f rence au milieu d une cl ture lectrique e proximit du r seau lectrique si l lectrificateur est aliment sur secteur e dune distance d au moins 1 m de la batterie et non pas directement au dessus de celle ci si l lectrificateur est aliment sur batterie Si votre installation se situe l ext rieur v rifiez en plus qu il soit install e sur un sol ferme l abri des inondations e l int rieur d une cl
33. d Strom e Fehlersuch Ger t Hilft beim Orten von Fehlern im Zaunsystem F r detaillierte Hinweise zum Gebrauch der Fernbedienung lesen Sie bitte die Bedienungsanleitung die jeder Fernbedienung beiliegt Warnhinweis Das Ger t beginnt nach einer Unterbrechung der Stromversorgung automatisch wieder zu arbeiten Dies passiert auch wenn das Ger t vor der Stromunterbrechung mit der Fernbedienung ausgeschaltet war Deshalb empfehlen wir zu Ihrer Sicherheit dass Sie bei l n geren Wartungsarbeiten am Zaun den entsprechenden Zaunabschnitt mit einem Zaunschalter stromlos schalten oder das Netzteil aus der Steckdose ziehen Kommunikation zwischen Ger t und Fernbedienung Das P4600 reagiert nur auf die Signale der Fernbedienung wenn die Fernbedienungsfunktion zuvor am Ger t aktiviert wurde Diese ist im Regelfall ab Werk aktiviert Sollte dies nicht der Fall sein muss diese Einstellung nur einmal durchgef hrt werden Ger t und Fernbedienung kommunizieren nur miteinander wenn bei beiden die gleichen Adressen eingestellt sind Aktivierung der Fernbedienungsfunktion Um zu sehen ob die Fernbedienungsfunktion des Ger tes aktiviert ist 1 Schalten Sie das Ger t mit dem Schalter auf Warten Sie 5 Sekunden dann schalten Sie das Ger t wieder auf einer beliebigen Position ein 2 Warten Sie bis das Ger t die Ausgangsspannung anzeigt 3 Wenn der Pfeil rechts im Display blinkt ist die Fernbedienungsfunktion nicht aktiviert 4
34. dans le mode souhait 2 Appuyez sur pour activer la t l commande 3 Tenez la t l commande une distance d environ 5 15 cm du poste et appuyez sur L lectrificateur arr te d envoyer des impulsions et dans la partie sup rieure de l cran vous pouvez lire OFF 4 Appuyez sur pour arr ter la t l commande 5 Restez appuy sur le bouton et en m me temps sur le bouton pour allumer la t l commande La t l commande est maintenant pr te pour changer le code 6 Appuyez plusieurs fois jusqu ce que AD apparaisse sur l cran 7 Restez appuy sur jusqu ce que le code d sir apparaisse Code de 1 15 8 Tenez la t l commande une distance d environ 5 15 cm du poste et appuyez sur La t l commande transmet le nouveau code au poste et apr s le poste montre le nouveau code pendant 2 secondes 9 Appuyez sur pour arr ter le poste 35 Montage d une d ture lectrique Les l ments de la cl ture lectrique Une cl ture lectrique se compose des l ment suivants e Un lectrificateur e Une prise de terre qui comporte un certain nombre de piquets de terre enfonc s dans le sol et connect s la borne de terre de l lectrificateur e Des c bles de raccordement qui connectent l lectrificateur la prise de terre et la cl ture lectrique e Une cl ture isol e connect e la borne de cl ture de lectrificateur Plusieurs types
35. de cl ture sont envisageables Remarque L animal re oit une d charge lectrique quand il boucle le circuit lectrique entre la cl ture et le sol La cl ture se compose de fils conducteurs et n cessite une bonne conductibilit du sol Electrificateur TR Fil lectrifi gt era Fil lectrifi Prise de terre lt Retour alaterre lt amp Les diff rents types de cl ture Vous pouvez choisir vos cl tures en fonction de l esp ce animale et du mat riel dont vous disposez Consultez votre distributeur PATURA pour trouver la solution la mieux adapt e vos besoins Cl tures lectriques permanentes PATURA vous propose toute une gamme de produits pour am nager des cl tures lectriques permanentes Ces cl tures install es de mani re appropri e pr sentent pour l exploitant les avantages suivants e l am nagement d un grand p rim tre e Une conductibilit du courant optimale sur longue distance e Des cl tures qui ne n cessitent aucun entretien pendant des ann es Cl tures lectriques mobiles PATURA vous propose toute une gamme de produits pour am nager des cl tures lectriques mobiles Ces cl tures install es de mani re appropri e pr sentent pour l exploitant les avantages suivants 36 e l am nagement de p turages ou de parcelles de plus petite taille e La s paration de diff rents troupeaux e La pratique du p t
36. de RL Y terre du gt Fil lectrifi voltm tre e Conseils de s curit Ces conseils sont conformes aux normes europ ennes de s curit EN 60335 2 76 Definitions des termes techniques utilis s lectrificateur de cl ture un appareil qui envoie la cl ture laquelle il est reli des impulsions de tension intervalles r guliers Cl ture un barrage pour les animaux ou pour raisons de s curit Il consiste en un ou plusieurs conducteurs comme des fils en m tal des barreaux ou des barres Cl ture lectrique une cl ture isol e de la terre qui comprend un ou plusieurs conducteurs soumis des impulsions lectriques que g n re un lectrificateur Circuit de la cl ture l ensemble des l ments ou composants d une cl ture lectrique qui conduisent le courant et sont reli s galvaniquement aux bornes de sortie ou pourraient l tre Piquet de terre pi ce m tallique que l on enfonce dans le sol proximit d un lectrificateur et qu on relie lectriquement sa borne de terre Ind pendant de toute autre prise de terre C ble de raccordement un conducteur lectrique qui connecte l lectrificateur la cl ture lectrique ou au piquet de terre Cl ture lectrique pour animaux une cl ture lectrique qui contient des animaux ou les tient loign s de certains p rim tres Fils conducteurs des fils qui transmettent les impulsions haute tension g n r es par
37. dung e Geeignet zum H ten verschiedenster Tiere e F gt den Tieren im Vergleich zu anderen Umz unungen wie beispielsweise Stacheldraht keine Verletzungen zu Installation Lesen Sie bitte alle Sicherheitshinweise in dieser Anleitung sorgf ltig bevor Sie das Ger t installieren W hlen Sie einen geeigneten Platz zur Installation des Ger tes Befolgen Sie diese Hinweise wenn Sie einen Platz zur Installation des Ger tes ausw hlen Wahlen Sie einen Ort e an dem eine gute Erdung erreicht werden kann e au erhalb der Reichweite von Kindern und Tieren e an dem das Ger t gut zug nglich ist Stellen Sie sicher dass das Ger t wie folgt installiert wird e In der N he Ihres Elektrozaunes e Vorzugsweise in der Mitte Ihres Elektrozaunes e In der N he einer Steckdose bei Verwendung des mitgelieferten Netzteiles e Mindestens in 1 m Abstand von der Batterie und nicht direkt dar ber bei Batteriebetrieb Wenn Ihr Installationsort im Freien ist vergewissern Sie sich auch e dass das Ger t auf festem Grund steht au erhalb jeder berflutungsgefahr e dass das Ger t wenn erforderlich innerhalb eines Schutzzaunes steht Gebrauch des Netzteiles und der Batterieanschlusskabel Das Ger t wird mit einem externen Netzteil zum Anschluss an das Stromnetz und einem Batterieanschlusskabelssatz zum Anschluss an eine Batterie geliefert Vor Anschluss des Netzteils oder Batteriekabels vergewissern Sie sich dass der Schalt
38. e 1 000 V Les lectrificateurs destin s l alimentation des installations de cl tures lectriques dans les p turages ne doivent surtout pas tre install s dans des locaux risque d incendie comme les granges les aires de battage ou les b timents pour les b tes Prot gez l installation de la foudre en montant un parafoudre un clateur avec mise la terre sur la ligne de raccordement juste avant qu elle entre l int rieur du b timent Si les cl tures lectriques sont destin es chasser les oiseaux contenir des animaux domestiques ou familiariser des animaux comme les vaches des cl tures lectriques il vous suffira d installer un lectrificateur de faible puissance pour obtenir un r sultat aussi satisfaisant que fiable Il est interdit de mettre un fil de la cl ture lectrique la terre si vous utilisez cette cl ture pour emp cher les oiseaux de se percher sur des b timents Installez des panneaux de signalisation comme d crit ci dessous partout o des personnes sont susceptibles d entrer en contact avec les fils conducteurs Lorsqu une cl ture lectrique croise un chemin d acc s public il faut pr voir une porte non lectrifi e ou un autre acc s de passage au niveau de l intersection et pourvoir cet endroit les fils conducteurs de panneaux de signalisation Il est obligatoire de signaler aux passants toutes les parties de la cl ture lectrique qui longent une route ou un chemin d acc s
39. e ou au secteur il se met en route apr s 3 secondes Les lampes de contr les montrent la tension de sortie en pleine puissance Chaque lampe correspond environ 1 kV 1000 V de tension de sortie Si par exemple les 8 premi res lampes s allument chaque impulsion la tension de sortie est d environ 8 kV 8000 V Rouge Vert NO N 0000000 GDRBDPPDPD w Note Si 10 lampes sont allum es la tension peut amp tre aussi au dessus de 10 kV 10 000 V Si amp chaque impulsion seules les lampes rouges s allument il y a des pertes importantes sur la cl ture et vous devez localiser les pertes sur votre cl ture Voir aussi Questions fr quentes r ponses en page 41 UN Tension de sortie Seulement P4600 Quand le poste fonctionne les deux grands chiffres montrent la tension de sortie avec pleine puissance Si les chiffres clignotent deux fois par seconde il n y a pas assez de tension sur votre cl ture Il peut s agir de pertes importantes sur la cl ture Voir aussi Questions fr quentes r ponses en page 41 Contr le de la prise de terre P4600 Pr paration Le syst me de contr le fonctionne en comparant la tension de la prise de terre avec la tension sur une piquet de terre s par Le piquet de terre pour le contr le de la prise de terre doit se trouver au moins 10 m de la prise de terre de la cl ture Utilisez un piquet d au moins 1 m et mettez le en terre Prenez un c ble i
40. e power supply if required 48 Installing the energiser outdoors The energiser may be installed outdoors powered by a battery Warning e Do not power the energiser with the mains line power supply if it is being installed outdoors To install the energiser outdoors 1 Select a suitable installation site See Selecting a site for the installation on page 47 nae 2 Hang the energiser on a fence wire or mount the energiser on a post Use the template printed on the back cover of this manual if required 3 Connect the Fence earth terminal green to the earthing system 4 P4600 only If earth monitoring is required connect the Fence earth monitor terminal black to a separate earth stake For more information see Earth monitoring on page 51 5 Connect the Fence full voltage terminal red or the Fence half voltage terminal yellow to the fence 6 Connect the energiser to the battery using the battery leads supplied Attach the red clip to the positive terminal of the battery and the black clip to its negative terminal Note If required this energiser can be used as part of a solar installation by connecting it to a solar panel and a battery For further information about solar installations please refer to our Electric Fencing Catalogue Installing the energiser as part of a solar installation The energiser may be installed with solar panels as part of a solar install
41. eis urebatterie verwendet werden 11 Umgang mit der Batterie Warnhinweis Batterien enthalten sch dliche Chemikalien und k nnen bei unsachgem em Gebrauch Verletzungen verursachen Beachten Sie unbedingt die Hinweise zur Batteriepflege und Sicherheit die Sie mit Ihrer Batterie erhalten haben Laden der Batterie Warnhinweis e Versuchen Sie nicht eine nicht aufladbare Batterie aufzuladen e Wenn Sie die Batterie aufladen stellen Sie sicher dass ausreichende Bel ftung gew hrleistet ist um die entstehenden Gase abzuf hren Regelm iges Nachladen der Batterien ist wichtig Benutzen Sie ein ausreichend dimensioniertes Ladeger t gem f3 den Empfehlungen des Batterieherstellers 1 Trennen Sie die Batterien vom Elektrozaunger t 2 Befestigen Sie das rote Plus Kabel des Ladeger tes mit dem Pluspol der Batterie und das schwarze Minus Kabel des Ladeger tes mit dem Minuspol der Batterie 3 Stecken Sie das Netzkabel des Ladeger tes oder das Ladeger t selbst in die Steckdose und schalten wenn erforderlich das Ladeger t ein 4 Wenn die Batterie geladen ist trennen Sie diese vom Ladeger t bevor Sie sie an das Elektrozaunger t anschlie en Warnhinweis berladen der Batterie reduziert deren Lebensdauer berschreiten Sie nicht die Empfehlungen des Batterieherstellers hinsichtlich der Ladezeiten Batteriepflege e Bewahren Sie die Batterie in einer daf r geeigneten Box auf wenn sie im Freien steht e W
42. elatives l entretien la maintenance et la s curit de la batterie dans le pr sent manuel et dans la documentation fournie avec votre batterie Chargement de la batterie Attention e Ne jamais charger une batterie non rechargeable e Pendant le chargement de la batterie assurer une ventilation ad quate pour permettre au gaz de se dissiper Il est important de charger la batterie r guli rement Utilisez un chargeur d une capacit nominale appropri e et r f rez vous aux recommandations du fabricant de la batterie 1 D connectez la batterie de l lectrificateur 2 Fixez le c ble rouge positif du chargeur sur la borne positive de la batterie et le c ble n gatif noir du chargeur sur la borne n gative de la batterie 3 Raccordez la fiche du chargeur ou le chargeur lui m me une prise lectrique et si n cessaire commencer le chargement 4 Le chargement de la batterie termin d connectez la batterie du chargeur avant de la connecter l lectrificateur Attention La surcharge de la batterie r duira sa dur e de vie Ne pas d passer les recommandations du fabricant de la batterie relatives la recharge de la batterie depuis une source aliment e sur secteur Entretien de la batterie e Logez la batterie dans une bo te batterie appropri e si elle est expos e aux intemp ries e Lorsque l lectrificateur est inutilise maintenez un niveau de charge aussi lev que possible e Rechargez
43. enn es mit Batterie betrieben wird 6 Warnhinweise e Schlie en Sie das Ger t nicht an das Netzteil an wenn es im Freien betrieben wird Zur Installation des Ger tes im Freien 1 W hlen Sie einen geeigneten Installationsort siehe Seite 5 W hlen Sie einen geeigneten Platz zur Installation des Ger tes 2 H ngen Sie das Ger t in einem Zaundraht ein oder montieren es an einem Pfosten Wenn erforderlich benutzen Sie die beigef gte Bohrschablone 3 Verbinden Sie den Erdungsanschluss gr n mit Ihrem Erdungssystem 4 Nur P4600 Wenn gew nscht verbinden Sie den Erdungskontrollanschluss schwarz mit einem separaten Erdstab F r weitere Informationen siehe Erdungskontrolle Seite 9 5 Verbinden Sie den Zaunanschluss f r volle Spannung rot bzw den Anschluss f r halbe Spannung gelb mit Ihrem Zaunsystem 6 Verbinden Sie das Ger t ber das mitgelieferte Batteriekabel mit der Batterie Verbinden Sie den roten Plusclip mit dem Pluspol der Batterie und den schwarzen Minusclip mit dem Minuspol der Batterie Hinweis Wenn gew nscht kann das Ger t als Teil einer Solaranlage betrieben werden indem es mit einem Solarmodul und einer Batterie verbunden wird F r weitere Informationen lesen Sie bitte in unserem Weidezaunkatalog Installation des Ger tes mit einer Solaranlage Das Ger t kann in Verbindung mit Solarzellen als Teil einer Solaranlage verwendet werden Eine Solaranlage besteht aus fol
44. enn nicht im Gebrauch erhalten Sie die Batterie m glichst in vollem Ladezustand e Laden Sie eine entladene Batterie so schnell wie m glich wieder auf e Batterien d rfen nur vollgeladen gelagert werden und m ssen regelm ig ca alle 8 Wochen nachgeladen werden e Kontrollieren Sie die Batterie regelm ig und stellen Sie sicher dass der S urestand nicht weiter abf llt als 12 mm ber den Platten in der Batterie Markierung beachten e Zum Nachf llen benutzen Sie destilliertes Wasser Nicht zu hoch auff llen F r weitere Informationen folgen Sie den Empfehlungen des Batterieherstellers Batteriesicherheit e Gew hrleisten Sie dass die Batterie beim Laden gut bel ftet wird e Vermeiden Sie Temperaturen ber 50 C e Vermeiden Sie dass die Batterie offenen Flammen oder Funken ausgesetzt ist 12 Gebrauch einer Fernbedienung nur P4600 Hinweis Das P4500 kann nicht mit einer Fernbedienung ausgeschaltet werden Das P4600 ist vorbereitet f r den Empfang von Signalen einer Fernbedienung Keine weitere Voreinstellungen sind notwendig Das Elektrozaunger t und die Fernbedienung sind vorprogrammiert um miteinander zu kommunizieren Die Fernbedienung mit Zaun Kompass beinhaltet 3 Ger te in einem Sie dient als e Fernbedienung Schaltet von jedem beliebigen Punkt im Zaunsystem aus das Elektrozaunger t ein oder aus e Spannungs Amperemessger t Liefert Echtzeit Informationen ber die Zaunleistung Spannung un
45. er am Ger t auf OFF steht Gebrauch des Netzteiles 1 Stecken Sie den Anschlussstecker des Netzteiles in den entsprechenden Anschluss auf der R ckseite des Ger tes Ber cksichtigen Sie die korrekte Polaritat 2 Stecken Sie das Netzteil in die Steckdose Stellen Sie sicher dass sich im Abstand von 25 mm rund um die Steckdose keine weiteren Teile befinden Entfernen des Netzteiles 1 Ziehen Sie das Netzteil aus der Steckdose 2 Ziehen Sie vorsichtig unter leichtem Wackeln den Stecker hinten aus dem Ger t Gebrauch der Batteriekabel Die Batterieanschlusskabel werden mit Ringverbindern geliefert die f r einen permanenten Anschluss an eine Batterie ideal sind da sie eine gute elektrische Verbindung gew hr leisten Wenn Ihre Batterie keine Anschlussm glichkeit f r Ringverbinder hat oder wenn Sie Ihr Ger t fter umsetzen und einen schnellen Anschluss an die Batterie w nschen 5 entfernen Sie bitte die Ringverbinder von den Anschlusskabeln und schlie en dort die Edelstahl Batterieklemmen polungsrichtig an 1 Verbinden Sie die rote Ring se bzw die rote Batterieklemme mit dem Batterie Pluspol und die schwarze mit dem Batterie Minuspol 2 Stecken Sie das Kabel in den Anschlussstecker auf der Ger te R ckseite Ber cksichtigen Sie die korrekte Polarit t Entfernen der Batteriekabel 1 Klemmen Sie die Ring sen bzw die Batterieklemmen von der Batterie ab 2 Fassen Sie das Batteriekabel an der Gummit lle an und z
46. ery 1 5 seconds The energiser is operating at half power and fast speed approximately 1 5 seconds between pulses The energiser is operating at full power and fast speed approximately 1 5 seconds between pulses When first connected to the power source the energiser starts pulsing after three seconds Each Indicator light segment represents an increment of approximately 1 kV 1 000 V of output voltage For example if the first eight Indicator light segments are illuminated at each pulse the output voltage is approximately 8 kV 8 000 V Red Green 4 N ff 00000000 GHBBDBDED w 50 Note If 10 Indicator light segments are illuminated the output voltage may be more than 10 kV 10 000 V If you see only red lights at each pulse and no green lights your fence line is very heavily loaded and you will need to look for faults on the fence line See Frequently asked questions Troubleshooting on page 61 P4600 only When the energiser is operating the large digits on the LCD display show the output voltage at the energiser s Fence full voltage terminal g g Output voltage Note If the large digits on the LCD display flashes twice per second it indicates that the fence voltage is too low There could be a serious fault on the fence See Frequently asked questi ons Troubleshooting on page 61 Earth monitoring P4600 only Setting up for earth monitoring The earth monitoring feature works b
47. for equipment grounding be added to the energiser Servicing a double insulated energiser requires extreme care and knowledge of the system and should only be done by qualified service personnel Replacement parts for a double insulated energiser must be identical to the parts they replace A double insulated energiser is marked with the words DOUBLE INSULATION or DOUBLE INSULATED and or the symbol below ol Product Specifications P4500 P4600 Power supply 12 V DC Battery 220 240 V AC 50 Hz Mains power adaptor Power consumption 230 V operation 10 W Current Consumption 12 V battery operation e Battery Test 410 mA e Day slow speed Night fast speed 530 mA average e Day slow speed Night fast speed 530 mA average e Half output power 330 mA e Full output power 650 mA Output voltage e No Load 9 5 kV e 500 0 6 8 kV Max Output energy 6 2 J Stored energy 9 0 J Dimensions W x H x D 250 x 240 x 90 mm Weight 2 5 kg PATURA KG Mainblick 1 T 49 0 9372 947 40 info patura com 63925 Laudenbach Germany Fax 49 0 9372 947 429 www patura com 64
48. genden Teilen e Elektrozaunger t e Aufladbare Batterie evtl auch mehrere e Solarzellen evil auch mehrere e Erdungssystem F r weitere Informationen zur Auswahl der geeigneten Solarzellen und Batterien informieren Sie sich bitte in unserem PATURA Weidezaunkatalog F r detaillierte Installationshinweise befolgen Sie bitte die Hinweise der separaten Bedienungsanleitung die jeder Solarzelle beiliegt Hinweise zur Installation und berpr fung der Erdung siehe Installation und berpr fung der Erdung auf Seite 16 Bedienung Schalterwahloptionen Wahlen Sie ber den Bedienschalter die Geschwindigkeits und Leistungsoptionen Einstellung Beschreibung OFF O Aus Das Ger t ist ausgeschaltet und arbeitet nicht Das P4600 reagiert nicht auf die Fernbedienung Batterietest Das Ger t arbeitet mit voller Leistung aber die 0 schnelle Impulsfolge Kontrollanzeigen informieren ber den Batteriezustand Siehe Batterietesteinstellung auf Seite 10 f r die Erkl rung der Kontrollanzeigen gt Tagsparschaltung Das Ger t arbeitet nachts bei voller Leistung EN Nachts schnell mit schneller Impulsfolge ca alle 1 5 Sekunden tags ber alle 2 5 Sekunden Nachtsparschaltung Das Ger t arbeitet nachts bei voller Leistung oy Nachts langsam mit langsamer Impulsfolge ca alle 2 5 Sekunden tags ber alle 1 5 Sekunden a Halbe Leistung Das Ger t arbeitet mit halber Leistung schnelle Impulsfolge und schneller Impulsfolge c
49. ges possibles de la fr quence des impulsions S lection de la batterie Le tableau ci dessous donne une orientation sur la capacit en amp re heure Ah de la batterie acide plomb 12 V requise pour chaque modele Les valeurs sont bas es sur une p riode de fonctionnement de 7 jours entre deux cycles de charge de la batterie Si l intervalle entre deux cycles de charge d passe les 7 jours ceci augmentera le risque d un endommagement de la batterie et aboutira des remplacements plus fr quents de la batterie Pour obtenir la meilleure fiabilit possible du syst me et une longue dur e de vie de batterie il est pr f rable d utiliser une batterie acide plomb d charge lente et de la recharger lorsqu elle s est d charg e un niveau de charge moyen Pour plus d informations sur le contr le du niveau de charge de la batterie voir Contr le de la batterie en page 31 Mode de fonctionnement Consommation Capacit Contr le de batterie 410 mA 150 Ah Lent la nuit 410 mA Rapide la nuit 650 mA 530 mA 24 heures en moyenne 190 Ah Rapide la journ e 650 mA Lent la nuit 410 mA 530 mA 24 heures en moyenne 190 Ah Demi puissance 330 mA 120 Ah Pleine puissance 650 mA 230 Ah Attention Une batterie rechargeable 12 V doit tre utilis e 32 Maniement de la batterie Attention Les batteries contiennent des produits chimiques nocifs et peuvent causer des blessures lors d une utilisation incorrecte Observez les instructions r
50. h monitor voltage is too high Use the earth monitoring illuminated permanently and feature to monitor the earth See Earth monitoring on page 51 the earth monitor voltage on the LCD display small digits flashes twice per second The battery symbol on the The battery voltage is too low Check the battery voltage imme LCD is flashing twice per diately using the battery test setting See Testing the battery second voltage on page 52 The right arrow on the LCD The energiser is searching for a remote control This occurs is flashing twice per second each time the energiser is switched on when the energiser s remote control feature has not been activated This is part of normal operation The energiser is not pulsing The battery voltage is bad and the energiser ceases to function and the last green Indicator OR light is flashing once per P4600 The energiser was turned off via a remote control second handset The energiser is not pulsing The connection to the battery seems faulty Check all battery and the first red Indicator connections Check the battery voltage immediately using the light is flashing twice per battery test setting See Testing the battery voltage on page second 52 Servicing This energiser uses Double Insulation where two systems of insulation are provided instead of grounding No equipment grounding means is provided in the supply cord of a double insulated energiser nor should a means
51. hzuladen Batteriesymbol ai Batterieauswahl und Umgang mit der Batterie Dieser Abschnitt bezieht sich ausschlie lich auf wiederaufladbare Bleis ure Batterien wie z B Auto Schlepper LKW oder Spezialbatterien Die Gr e der Batterie h ngt von Ihrem Ger t und der Schalterstellung ab die Sie bevorzugt einstellen Hinweise zur Funktion der Schalterstellungen siehe Seite 8 Schalterwahloptionen Batterieauswahl Als grobe Richtlinie k nnen Sie aus untenstehender Tabelle die empfohlene Gr e der erfor derlichen Batterie f r Ihr jeweiliges Ger temodel ausw hlen Diese Tabelle basiert auf einer 7 t gigen Betriebsdauer bis zum n chsten Nachladen Das Batterienachladeintervall kann auch ber 7 Tagen liegen dies kann jedoch die Batterie sch digen und zu h ufigerem Aus tausch der Batterie f hren F r h chste Zuverl ssigkeit und Lebensdauer der Batterie verwen den Sie m glichst tiefentladefeste Bleis urebatterien und laden diese m glichst nach wenn sie zur H lfte entladen sind F r weitere Informationen siehe Batterietest Einstellungen Seite 10 Schalterstellung Stromverbrauch Batteriekapazit t Batterietest 410 mA 150 Ah Langsam am Tag 410 mA Schnell in der Nacht 650 mA 530 mA 24 Stunden Durchschnitt 190 Ah Schnell am Tag 650 mA Langsam in der Nacht 410 mA 530 mA 24 Stunden Durchschnitt 190 Ah Halbe Leistung 330 mA 120 Ah Volle Leistung 650 mA 230 Ah Warnhinweis Es muss eine wiederaufladbare 12 V Bl
52. iehen es vorsichtig unter leichtem Wackeln hinten aus dem Ger t Installation des Ger tes in Geb uden Das Ger t muss im Geb udeinneren installiert werden wenn es mit Netzteil betrieben wird Warnhinweise e Verwenden Sie kein Verl ngerungskabel zum Anschluss des Netzteils e Lassen Sie mindestens 25 mm Abstand zwischen Netzteil und anderen Objekten Zur Installation des Ger tes im Inneren 1 W hlen Sie einen geeigneten Installationsort siehe Seite 5 W hlen Sie einen geeigneten Platz zur Installation des Ger tes 2 Montieren Sie das Ger t an einer Wand Wenn erforderlich benutzen Sie die beigef gte Bohrschablone 3 Verbinden Sie den Erdungsanschluss gr n 25mm Abstand mit Ihrem Erdungssystem 4 Nur P4600 Wenn gew nscht verbin den Sie den Erdungskontrollanschluss Isoliertes Hochspannungs kabel schwarz mit einem separaten Erdstab F r weitere Informationen sehen Sie Erdungskontrolle Seite 9 5 Verbinden Sie den Zaunanschluss f r volle Spannung rot bzw den Anschluss f r halbe Spannung gelb mit Ihrem Zaunsystem 6 Verbinden Sie das Elektrozaunger t ber das mitgelieferte Netzteil mit dem Stromnetz Hinweis Wenn das Ger t im Geb udeinneren installiert wird kann es wenn gew nscht auch mit Batterie anstelle des Netzteils betrieben werden Installation des Ger tes im Freien Das Ger t kann im Freien installiert werden w
53. is energiser is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the energiser safely Young children should be supervised to ensure that they do not play with the energiser An electric fence shall not be supplied from two or more separate energisers For any two separate electric fences each supplied from a separate energiser independently timed the distance between the wires of the two electric fences shall be at least 2 5 m 8 If this gap is to be closed this shall be effected by means of electrically non conductive material 59 or an isolated metal barrier Barbed wire or razor wire shall not be electrified by an energiser A non electrified fence incorporating barbed wire or razor wire may be used to support one or more offset electrified wires of an electric fence The supporting devices for the electrified wires shall be constructed so as to ensure that these wires are positioned at a minimum distance of 150 mm 6 from the vertical plane of the non electrified wires The barbed wire and razor wire shall be earthed at regular intervals For safety reasons we recommend for offset fences only to use energisers with a maximum of 5 joules output energy Follow our recommendations regarding earthing See Installing and testing an earth system on page 59 A distance of at least 10 m 33 shall be maintained between the energ
54. ise Sicherheitshinweise gem f3 dem europ ischen Sicherheitsstandard EN 60335 2 76 Definition verwendeter Fachbegriffe Elektrozaunger t Ein Ger t das in regelm igen Abst nden Spannungsimpulse an den angeschlossenen Zaun schickt Zaun Eine Absperrung f r Tiere oder zu Sicherheitszwecken bestehend aus einem oder mehreren Stromleitern wie beispielsweise Metalldr hten oder Stangen bzw Riegeln Elektrozaun Ein von der Erde isolierter Zaun mit einem oder mehreren Leitern durch den von einem Elektrozaunger t aus Stromst e geschickt werden Zaunstromkreis Alle leitenden Teile oder Komponenten in einem Elektrozaun die galvanisch mit den Ausgangsklemmen verbunden sind oder verbunden werden k nnen Erdstab Ein Metallteil das in der N he eines Elektrozaunger ts in den Boden versenkt und elektrisch an den Erdungsanschluss des Elektrozaunger ts angeschlossen wird und das von anderen Erdungssystemen unabh ngig ist Anschlusskabel Ein elektrischer Leiter zum Anschluss des Elektrozaunger ts an den elektrischen Weidezaun oder den Erdstab Elektrischer Weidezaun Ein Elektrozaun zum H ten von Tieren oder zum Fernhalten von Tieren von bestimmten Bereichen Stromf hrende Leiter Dr hte durch die Hochspannungsimpulse vom Elektrozaunger t geschickt werden Anforderungen an elektrische Weidez une Elektrische Weidez une und die zugeh rigen Zusatzger te sind so zu installieren bedienen und warten dass die Gef
55. iser earth stake and any other earthing system connected parts such as the power supply system protective earth or the telecommunication system earth Connecting leads that are run inside buildings shall be effectively insulated from the earthed structural parts of the building This may be achieved by using insulated high voltage cable Connecting leads that are run underground shall be run in conduit of insulating material or else insulated high voltage cable shall be used Care must be taken to avoid damage to the connecting leads due to the effects of animal hooves or vehicle wheels sinking into the ground Connecting leads shall not be installed in the same conduit as the mains supply wiring communication cables or data cables Connecting leads and electric fence wires shall not cross above overhead power or communication lines Crossings with overhead power lines shall be avoided wherever possible If such a crossing cannot be avoided it shall be made underneath the power line and as nearly as possible at right angles to it If connecting leads and electric fence wires are installed near an overhead power line the clearances shall not be less than those shown in the table below Minimum clearances from power lines for electric fences Power line voltage Clearance lt 1 000 V 3 m 10 gt 1 000 lt 33 000V 4m 13 gt 33 000 V 8m 27 If connecting leads and electric fence wires are installed near an overhead power line their height
56. l lectrificateur Conditions requises pour les d tures lectriques L installation le fonctionnement et la maintenance des cl tures lectriques et de leurs accessoires doivent tre r alis s de telle sorte que les personnes les animaux et leur 38 environnement n encourent aucun danger Les installations de cl tures lectriques susceptibles de pi ger des personnes ou des animaux sont tr s dangereuses et donc amp viter MISE EN GARDE Eviter d entrer en contact avec les fils de cl ture lectrique en particulier avec la t te le cou ou le torse Ne pas passer au dessus en dessous ni entre les fils d une cl ture lectrique fils multiples Utiliser une porte ou un point de passage construit sp cialement Cet lectrificateur n est pas con u pour tre utilis par des enfants sans surveillance ou des personnes handicap es moins que ces personnes ne soient sous la responsabilit d une personne capable d assurer le maniement de l appareil en toute s curit Les enfants doivent tres gard s sous surveillance pour s assurer qu ils ne jouent pas avec lectrificateur Ne jamais connecter une cl ture lectrique deux ou plusieurs lectrificateurs La distance entre les fils de deux cl tures lectriques aliment es par deux lectrificateurs diff rents et sur des fr quences ind pendantes doit comporter au moins 2 5 m tres Si on souhaite fermer cet espace il faudra utiliser des mat riaux no
57. l Refer to the battery manufacturer s recommendations for more information Battery safety e Ensure that the battery is well ventilated when recharging e Avoid temperatures greater than 50 C 120 F e Ensure the battery is not exposed to naked flame or sparks 54 Using a remote control handset P4600 only Note The P4500 energiser cannot be used with a remote control handset The P4600 will accept commands from a remote control handset No configuration is required The energiser and remote control are pre programmed to communicate The remote control handset with Fence compass is three tools in one It acts as a e Remote control Switching the energiser on or off from any location on the electric fence system e Voltmeter Ammeter providing instant feedback on fence performance voltage and current e Fault finder Assisting in the location of faults anywhere on the fence system For detailed instructions on using the remote control handset refer to the user manual supplied with the handset Warning The energiser will reactivate following a power failure even if it was switched off via remote control handset prior to the power failure Therefore for your safety we recommend that you deactivate the isolated section with a cut out switch or disconnect the energiser from its power source while doing lengthy maintenance work on the fence Communication between energiser and remote control The P4600 will acce
58. mboles qui peuvent tre repr sent s sur I lectrificateur al 1 u l 3 5 2 oH Borne de terre de la cl ture Connectez la borne de terre votre syst me de mise la terre Borne contr le terre seulement P4600 Connectez cette borne avec un piquet de terre s par voir aussi page 30 Borne tension r duite Connectez la borne avec votre cl ture Borne pleine tension Connectez la borne avec votre cl ture Afin d viter tout risque de choc lectrique l lectrificateur ne pourra tre ouvert et r par que par un personnel qualifi et agr e PATURA Lire attentivement le mode d emploi avant utilisation Assurez le recyclage du produit selon la r glementation nationale en vigeur Electrificateur double protection Comment fonctionne une cl ture lectrique Une cl ture lectrique comprend un lectrificateur et une cl ture isol e L lectrificateur applique des impulsions lectriques tr s br ves la ligne de cl ture Ces impulsions sont d une tension lev e mais d une dur e tr s courte inf rieure 3 10 000 de seconde La d charge provoqu e par l impulsion lectrique est n anmoins tr s d sagr able de sorte que les animaux apprennent tr s vite respecter la cl ture lectrique Une cl ture lectrique est non seulement une barri re physique mais aussi mentale Quels sont les avantages d une cl ture lectrique En comparaison avec la
59. n F r Elektroz une zur Abschreckung von V geln zur Einz unung von Haustieren oder zur Gew hnung von Tieren wie K hen an Elektroz une reicht ein Elektrozaunger t mit geringer Leistung um ein zufriedenstellendes und zuverl ssiges Ergebnis zu erzielen Bei Elektroz unen die V gel davon abhalten sollen sich auf Geb uden niederzulassen sollte kein Zaundraht geerdet sein An s mtlichen Stellen an denen Personen mit den Leitern in Ber hrung kommen k nnten ist ein Warnschild nach dem unten gezeigten Vorbild anzubringen Kreuzt ein elektrischer Weidezaun einen ffentlichen Weg ist im Elektrozaun am Ort der Kreuzung ein stromfreies Tor oder ein anderer Zugang vorzusehen An jeder solchen Kreuzung sind die stromf hrenden Dr hte mit Warnschildern zu versehen S mtliche Abschnitte eines elektrischen Weidezauns die entlang einer ffentlichen Stra e oder eines ffentlichen Wegs verlaufen sind in kurzen Abst nden mit Sicherheitsschildern 19 zu kennzeichnen die fest an den Zaunpf hlen oder an den Dr hten montiert werden e Die Abmessungen der Warnschilder m ssen mindestens 100 x 200 mm betragen e Als Hintergrundfarbe f r beide Seiten der Warnschilder ist gelb zu w hlen Der Aufdruck auf dem Schild muss schwarz sein und entweder folgender Abbildung entsprechen oder ein Text des Inhalts Vorsicht Elektrotierzaun wiedergeben e Der Aufdruck muss unl schbar und mindestens 25 mm hoch sein Achten Sie darauf dass
60. n conducteurs ou une barri re m tallique isol e Il est interdit de connecter des fils barbel s l lectrificateur Si vous d sirez doubler les fils conducteurs d une cl ture lectrique d une autre cl ture en fil barbel ou barbel tranchant il faut placer les piquets porteurs des fils conducteurs de telle mani re qu il reste un espace d au moins 15 cm entre les fils conducteurs et le plan vertical des fils non conducteurs Il faut galement mettre les fils barbel s la terre intervalles r guliers Pour des raisons de s curit nous vous conseillons d utiliser pour ces cl tures sur isolateurs distance des lectrificateurs ayant une nergie d impulsion de moins de 5 joules Suivez nos conseils de mise la terre Reportez vous au chapitre Installation et v rification de la prise de terre page 37 Veillez respecter une distance de 10 m minimum entre les piquets de terre de l lectrificateur et d autres quipements reli s eux m mes une prise de terre par exemple la mise la terre de l alimentation en courant ou du r seau t l phonique Il faut isoler efficacement les lignes de rattachement qui passent dans des b timents des l ments reli s la terre de ces derniers Pour ce vous pouvez utiliser des c bles isol s de haute tension Les lignes de raccordement souterraines doivent tre install es dans des gaines isolantes vous pouvez galement utiliser des c bles isol s haute tension
61. n ist Hinweis Steht der Schalter auf der Position Batterietest a gibt das Ger t weiterhin Strom an den Zaun ab Kontrolllampen Spannung Ladezustand Batterie C Uber 17 0 V Batterie berladen oder falsche Batterie O0000000 8 12 6 17 0V Sehr guter Ladezustand der Batterie 80 100 e Keine Ma nahmen erforderlich 0000006 gt 123 126V Guter Ladezustand der Batterie 50 80 0e000 12 0 12 3V e Keine Ma nahmen erforderlich QII 117 120V Mittlerer Ladezustand der Batterie 20 50 e Verfolgen Sie den Ladezustand der Batterie e Laden Sie die Batterie nach um langfristig Sch den zu verhindern e 112 117V Schlechter Ladezustand der Batterie 10 20 e Laden Sie die Batterie sofort nach e Das Ger t schaltet automatisch auf langsame Impulsfolge und halbe Leistung um Unter 11 2 V Sehr schlechter Ladezustand der Batterie 0 20 e Laden Sie die Batterie sofort nach e Das Ger t schaltet automatisch ab Tiefent ladeschutz um Strom zu sparen Die letzte griine LED blinkt einmal pro Sekunde 10 Hinweise e Bei extremen Temperaturen k nnen Abweichungen von oben genannten Ladezustand auftreten e Nach 30 Sekunden schaltet das Display wieder von der Anzeige der Batteriespannung zur Anzeige der Zaunspannung um Nur P4600 Wenn der Ladezustand der Batterie schlecht ist blinkt das Batteriesymbol in der Anzeige zweimal pro Sekunde Wir empfehlen die Batterie sofort nac
62. nbedienungssignals e Benutzen Sie Fehlersuchfunktion der Fernbedienung um Fehler im Zaun zu lokalisieren e Kontrollieren Sie allen Verbindungen vom Ger t zum Zaun und zur Erdung Stellen Sie sicher dass das Ger t mit einer Stromquelle verbunden und eingeschaltet ist e Versuchen Sie das Ger t direkt am Zuleitungskabel zum Zaun ein oder auszuschalten oder indem Sie die Fernbedienung in 15 bis 30 cm Abstand vor das Elektrozaunger t halten und dann die entsprechende Taste dr cken Wenn das Elektrozaunger t immer 21 noch nicht reagiert haben Elektrozaunger t und Fernbedienung evil unterschiedliche Adressen voreingestellt Siehe ndern der Adresse f r die Fernbedienung Seite 14 und Aktivierung der Fernbedienungsfunktion Seite 13 Ich m chte die Fernbedienungsfunktion des Ger tes abschalten Wenn sie eine Fernbedienung besitzen lesen Sie in der Anleitung zur Fernbedienung nach Wenn nicht lassen Sie die Funktion von Ihrem Fachh ndler deaktivieren Das Ger t schaltet sich manchmal unerwartet ab e Eine nahegelegene Zaunanlage wird mit einem Elektrozaunger t mit der gleichen Adresseinstellung betrieben Siehe ndern der Adresse f r die Fernbedienung Seite 14 Wenn das Problem weiterhin besteht kontaktieren Sie Ihren PATURA Fachh ndler Fehlersuche Die Anzeige f r die Aus Die Zaunspannung ist zu niedrig Es k nnte ein Fehler im Zaun gangsspannung gro e vorliegen Siehe auch Wie kann ich einen Defekt orten
63. nd berpr fung eines Erdungssystems auf Seite 16 Suchen Sie Ihren Zaun nach Defekten ab Die h ufigste Ursache f r niedere Spannungswerte sind Defekte in der Zaunleitung Sind der Zaun die Erdung und das Elektrozaunger t in einem guten Zustand und die Spannung ist dennoch unter 4 kV wenden Sie sich an Ihren PATURA H ndler Er wird Ihnen behilflich sein herauszufinden ob k rzlich durchgef hrte Erweiterungen Ihres Zauns oder der Zustand des Bodens die Ursache f r die unzureichende Spannung sein k nnten Wie kann ich einen Defekt orten F r die Fehlersuche empfehlen wir den PATURA Zaun Kompass oder die PATURA 20 Fernbedienung Diese kombinierten Spannungs und Strommessger te erm glicht das schnel le Finden von Stellen mit starkem Stromverlust Alternativ dazu k nnen Sie ein PATURA Digital Voltmeter oder einen Zaunpr fer verwenden Verwenden Sie Zaunschalter um die Stromversorgung einzelner Zaunabschnitte zu unterbrechen Steigt die Zaunspannung wenn ein Zaunabschnitt abgeschaltet ist untersuchen Sie diesen Abschnitt auf m gliche M ngel Auf dem Elektrozaunger t blinkt kein L mpchen berpr fen Sie die Stromversorgung Vergewissern Sie sich dass die Stromversorgung eingeschaltet ist Falls das Elektrozaunger t dennoch nicht funktioniert lassen Sie es von Ihrem PATURA Kundendienst berpr fen Das Ger t reagiert nicht auf Signale von der Fernbedienung e Vergewissern Sie sich dass Sie ein P4600 haben Das
64. nfach zu montieren ist kann der Landwirt e kleinere Koppeln Felder einz unen e Tierherden getrennt halten e das Futter rationieren Hinweis F r kleinere und wildere Tiere sollten Sie zus tzliche Dr hte verwenden Falls eine gr ere Sichtbarkeit des Zauns erforderlich ist z B bei Pferden sollte ein Kunststoffbreitband verwendet werden Installation und berpr fung eines Erdungssystems Wahlen Sie einen geeigneten Ort f r das Erdungssystem Dieser Ort muss e mindestens 10 m von anderen Erdungssystemen wie z B Telefon und Stromleitungen entfernt sein e abseits von Tieren oder anderen Verkehrsbewegungen liegen die die Installation beeintr chtigen k nnten e f r Wartungszwecke leicht berwachbar sein e idealerweise ber feuchten Boden verf gen also an einem schattigen oder sumpfigen Platz Die Erdung muss nicht direkt neben dem Elektrozaunger t sein Versenken Sie PATURA Erdst be im Boden Verwenden Sie ein isoliertes Hochspannungskabel und Erdungsklemmen um die Erdst be mit dem Erdungsanschluss des Elektrozaunger tes in Reihe zu schalten Achten Sie darauf dass die Isolierung weit genug abgezogen wird um einen guten Kontakt zwischen dem Draht und dem Erdstab zu gew hrleisten Die Tabelle unten zeigt die empfohlene Mindestanzahl an 1 bis 2 m langen Erdst ben f r ein Erdungssystem H ufig speziell bei schlecht leitf higen und trockenen B den sind mehrere bzw l ngere Erdst be erforderlich
65. niques de construction les plus r centes Il est con u pour offrir une performance et une long vit maximales Il est essentiel de lire attentivement ces instructions Elles contiennent d importantes informations de s curit et vous permettront d assurer un fonctionnement fiable et optimal de votre cl ture lectrique Attention teignez l lectrificateur avant tout travail d installation ou toute autre intervention sur la cl ture e Lisez attentivement toutes les r gles de s curit Voir Conseils de s curit la page 38 e V rifiez soigneusement que votre cl ture est en conformit avec tous les r glements locaux de s curit e Ne raccordez jamais un lectrificateur simultan ment une cl ture et un autre appareil tel qu un syst me de dressage de b tail La foudre pouvant atteindre votre cl ture risque de s tendre tous les autres appareils e Utilisez uniquement l adaptateur secteur ou les c bles de batterie fournis avec cet lectrificateur ou les pi ces de rechange d origine NOTE Ce produit a t con u pour une utilisation avec des cl tures lectriques pour animaux Les l ments de l lectrificateur T moins lumineux LED Affichage digital __ Connexion secteur Bouton de r glage Borne Borne Borne Borne prise controle tension cl ture deterre terre noire r duite pleine tension verte seulement jaune rouge P4600 25 Explication des sy
66. nt intervals by warning signs securely fastened to the fence posts or firmly clamped to the fence wires e The size of the warning sign shall be at least 100 x 200 mm 4 x 8 e The background colour of both sides of the warning sign shall be yellow The inscription on the sign shall be black and shall be either like the illustration to the right or the substance of CAUTION Electric animal fence e The inscription shall be indelible inscribed on both sides of the warning sign and have a height of at least 25 mm 1 Ensure that all mains operated ancillary equipment connected to the electric fence circuit provides a degree of isolation between the fence circuit and the supply mains equivalent to that provided by the energiser Protection from the weather shall be provided for the ancillary equipment unless this equipment is certified by the manufacturer as being suitable for use outdoors and is of a type with a minimum degree of protection IPX4 Frequently Asked Questions Troubleshooting What voltage is required to control animals 4 kV is widely accepted as the recommended minimum voltage to control animals However you also require a well constructed fence system to ensure that animals cannot push through electrified wires 61 m The fence voltage is below 4 kV How do increase the voltage Check the energiser Ensure that the energiser is not set on half power Disconnect the energiser from the fence and earth sys
67. nutes apr s la mise en fonction du poste 1 Assurez vous que le code de la t l commande est sur 1 plus de d tails dans le manuel de la t l commande Mettez le poste en mode Attendez 5 secondes et mettez le poste dans le mode souhait Attendez que l lectrificateur montre la tension de sortie Appuyez sur pour allumer la t l commande O 5 ND Tenez la t l commande une distance d environ 5 15 cm du poste et appuyez sur Le poste arr te d envoyer des impulsions et dans la partie sup rieure de l cran vous pouvez lire OFF La fl che droite arr te de clignoter et reste allum e en permanence Changement du code t l commande Il se peut que vous vouliez changer le code de votre lectrificateur dans les cas suivants e si vous avez plusieurs postes avec t l commande et que vous voulez qu une t l commande teigne seulement un poste e si sur la cl ture voisine le poste et la t l commande ont le m me code que le v tre e si votre poste s est teint de fa on impromptue L utilisation de diff rents codes pour chaque poste emp che que le poste soit allum ou soit teindre sans le vouloir Les lectrificateurs sont tous cod s sur l adresse 1 La fonction t l commande peut tre chang e seulement dans les 10 premi res minutes apr s la mise en fonction du poste Changement du code de la t l commande 1 Mettez le poste en mode Attendez 5 secondes et mettez le poste
68. odel of energiser you have and the pulse speed switch position you use most frequently Refer to Operation on page 50 for an explanation of the function of the pulse speed switch Battery selection As a guide the recommended battery size in amp hour Ah required for each energiser model is shown below This table is based on a 7 day operating period between battery charging Although operating time can exceed 7 days this is likely to cause battery damage and will necessitate frequent replacement of the battery For best system reliability and long term battery life the preferred battery and charging regime is to use a deep cycle lead acid battery and to recharge it when it has discharged to about halfway For more information on testing battery charge level see Testing the battery on page 52 Selector switch position Current required Battery capacity Battery test 410 mA 150 Ah Slow Speed Day 410 mA Fast Speed Night 650 mA 530 mA 24 hours average 190 Ah Fast Speed Day 650 mA Slow Speed Night 410 mA 530 mA 24 hours average 190 Ah Half power 330 mA 120 Ah Full power 650 mA 230 Ah Warning A rechargeable 12 V lead acid battery must be used 53 Battery management Warning Batteries contain harmful chemicals and when used incorrectly may cause injury Observe the guidelines for battery care maintenance and safety in the documentation supplied with your battery Battery charging Warning e Do not attempt to
69. patura BEDIENUNGSANLEITUNG Beachten Sie alle Hinweise vor Inbetriebnahme MODE D EMPLOI Lire toutes les instructions avant l usage USER MANUAL Read full instructions before use Inhaltsverzeichnis Table des mati res Table of Contents DEUTSCH 3 Elektroz une und Ihr neues PATURA Elektrozaunger t 3 Installation 5 Bedienung 8 Batterieauswahl und Umgang mit der Batterie 11 Gebrauch der Fernbedienung 13 Errichtung eines Elektrozaunes 15 Sicherheitshinweise 17 H ufige Fragen Probleml sungen 20 Wartung 23 Technische Daten 23 FRANCAIS 25 Les cl tures lectriques et votre nouvel lectrificateur PATURA 25 Installation 27 Utilisation 29 Utilisation de la t l commande 34 Montage d une cl ture lectrique 36 Conseils de s curit 38 Questions fr quemment pos es Solutions Al Maintenance AA Fiche technique AA ENGLISH 45 Electric Fencing and your PATURA Energiser A5 Installation 47 Operation 50 Using a remote control handset 55 Building an Electric Fence 57 Safety Considerations 59 Frequently Asked Questions Troubleshooting 61 Servicing 64 Specifications 64 DEUTSCH Elektroz une und Ihr neues PATURA Elektrozaunger t Herzlichen Gl ckwunsch zum Kauf eines Elektrozaunger ts der Marke PATURA Dieses Produkt wurde mit Hilfe der neuesten Technologie und Konstruktionstechniken entwickelt Es ist auf maximale Leistung und eine lange Lebensdauer ausgerichtet Es ist wichtig dass Sie die vorliegende
70. pt commands from a remote control handset when the remote control feature is activated on the energiser As a rule it is pre programmed at the factory In case this did not happen it has to be activated one time only The energiser and the remote control will communicate when both are set to the same address setting Activating the energiser for use with a remote control To find out if the remote control feature is activated on the energiser 1 Move the switch of the energiser to Wait 5 seconds and switch it back on to the desired position 2 Wait for the display of the output voltage 3 A blinking arrow at the right of the display indicates that the remote control feature is not activated If the arrow at the right of the display i IS continuously lit the remote control feature is activated BE To activate the remote control feature on the energiser Note During the first 10 minutes of operation the energiser s remote control feature can be activated 55 Ensure the code of the remote control is set to 1 refer to the operating instructions of the remote control handset for more information Move the switch of the energiser to O Wait 5 seconds and switch it back on to the desired position Wait for the display of the output voltage Press to turn on the remote control handset Hold the remote control handset within 5 t015 cm of the energiser and press The energiser will stop pulsing and the word OFF
71. r long fences Temporary electric fencing PATURA offers a range of products that allow the farmer to construct temporary electric fences A temporary fence that can be quickly erected and easily moved allows the farmer to e Make smaller paddocks fields e Keep herds of animals separated e Ration feed Note Use more wires for smaller animals and wild animals Polytape should be used when greater visibility is required e g horses 57 Installing and testing an earth system Select a suitable site for the earth system Site needs to be e At least 10 m 33 from other earth systems e g telephone mains power or the earth system from another energiser e Away from stock or other traffic that could interfere with the installation e At a site that can be easily observed for maintenance e Ideally at a site that has damp soil e g a shaded or swampy location Note that the earth does not need to be directly adjacent to the energiser installation Drive PATURA earth stakes into the ground Use high voltage insulated cable and earth clamps to continuously connect the earth stakes and the energiser s Earth terminal Make sure the insu lation is stripped back to ensure good contact between the wire and the earth stake The table below specifies the minimum number of 1m 3 3 earth stakes recommended for an earthing system Often especially with bad conducting or dry soil more respectively longer earth stakes are ne
72. roit d installation appropri Voir Choisir un endroit d installation la page 27 2 Fixez l lectrificateur sur un fil de la cl ture Ser 5 Rouge ou montez le sur un piquet Si n cessaire utilisez le gabarit imprim sur la couverture arri re du pr sent manuel 3 Reliez la borne de terre de la cl ture verte au syst me de mise la terre 4 Pour le P4600 si souhait vous pouvez brancher la borne contr le de prise de terre noire avec un piquet de terre s par Pour plus de d tails voir page 30 Contr le de la prise de terre 28 5 Connectez la borne pleine tension rouge ou demi tension jaune la cl ture 6 Connectez le poste la batterie l aide des c bles inclus Branchez la pince rouge positif sur la borne positive et la pince noire avec la borne n gative Si n cessaire cet lectrificateur peut tre int gr une installation solaire pour ceci connectez le une batterie et un ou plusieurs panneaux solaires Pour obtenir plus d informations sur les installations solaires veuillez vous r f rer notre catalogue cl ture Installation avec panneau solaire L lectrificateur peut fonctionner avec une installation solaire Cette installation est faite e d un lectrificateur e d une ou plusieurs batteries rechargeables e d un ou plusieurs panneaux solaires e d une prise de terre Pour choisir le bon panneau et la bonne batterie veuillez vou
73. rottez le contact d enclenchement au fil de la cl ture de fa on liminer la couche de rouille ou d oxydation e Veillez ce qu aucun portail de la cl ture ne soit rest ouvert et aucun interrupteur ne soit actif arrive que la t l commande fonctionne en d pit de petites coupures du fil mais dans ces conditions la fiabilit du fonctionnement ne peut plus tre garantie e Contr lez si vous avez des endroits sur la cl ture o le courant se propage par tincelles ou des raccordements distendus Beaucoup d tincelles nuisent au bon fonctionnement de la t l commande e Utilisez la fonction d tecteur de pertes pour localiser des d fauts e Assurez vous que les c bles de raccordement de l lectrificateur soient bien reli s l alimentation en courant et au systeme de cl ture Veillez ce que l lectrificateur ait une bonne prise de terre e Essayez de mettre l lectrificateur en marche et de l arr ter en maintenant le contact d enclenchement sur le c ble de sortie ou en tenant la t l commande proximit du poste une distance d environ 15 30 cm Si l appareil ne r agit toujours pas il est possible que la t l commande et l lectrificateur aient des codes diff rents Voir les chapitres Changement du code de la t l commande page 35 et Activation fonction t l commande page 34 Eteindre la fonction t l commande Si vous poss dez une t l commande veuillez lire son man
74. s reporter amp notre catalogue cl ture Pour plus de d tails d installation veuillez lire le mode d emploi de chaque panneau solaire Pour l installation et le contr le d une bonne prise de terre veuillez voir en page 37 Utilisation Selection mode d operation Choisissez par le bouton de r glage la rapidit amp et la puissance du poste R glage Description OFF O Eteint Le poste est teint et ne fonctionne pas Le P4600 ne r agit pas la t l commande N J Pleine puissance avec L lectrificateur fonctionne en pleine puissance et contr le de la batterie indique le niveau de la batterie Voir Reglage test de batterie en page 31 pour obtenir plus d explications sur les indicateurs lumineux EN Ralenti jour L lectrificateur fonctionne en mode ralenti impul Rapide nuit sions toutes les 2 5 sec pendant le jour en mode rapide pendant la nuit en pleine puissance vy Rapide jour L lectrificateur fonctionne en mode rapide impul Ralenti nuit sions toutes les 1 5 sec pendant le jour en mode ralenti pendant la nuit en pleine puissance Demi puissance L lectrificateur fonctionne en demi puissance en mode rapide rapide environ 1 5 secondes entre deux impulsions Pleine puissance U lectrificateur fonctionne en pleine puissance rapide en mode rapide environ 1 5 secondes entre deux impulsions 29 Contr ler la tension Apres avoir branch l lectrificateur la batteri
75. sections de la cl ture Si vous constatez que la tension de la cl ture augmente quand une section de la cl ture est d connect e examinez celle ci tout particuli rement pour voir si elle pr sente des anomalies Les t moins lumineux de l lectrificateur ne dignotent pas V rifiez l alimentation lectrique Assurez vous que l appareil est en service Si l lectrificateur ne fonctionne toujours pas portez le pour v rification un service apr s vente PATURA 41 L electrificateur ne r agit pas a la t l commande e Assurez vous que vous poss dez un P4600 et non un P4500 Le P4500 ne r agit pas la telecommande e Assurez vous que le contact soit tabli entre la t l commande et le fil de la cl ture avant d appuyer sur les touches ou amp Vous n obtiendrez pas de meilleur r sultat en appuyant longuement sur la touche Attendez 2 secondes apr s avoir appuy sur la touche ou jusqu ce que l indication ON ou OFF disparaisse de l cran car il est possible que l lectrificateur envoie encore une derni re impulsion apr s le signal de d sactivation De m me attendez 2 secondes pour que l lectrificateur envoie sa premi re impulsion quand vous le r activez e Si le symbole de la batterie appara t sur la t l commande changez la pile de la t l commande e La rouille ou l oxydation d un fil de la cl ture peuvent nuire la qualit du signal re u Pour obtenir un signal clair f
76. skontrolle Seite 9 Zaunanschluss halbe Spannung Verbinden Sie diesen Anschluss mit Ihrem Zaun Zaunanschluss volle Spannung Verbinden Sie diesen Anschluss mit Ihrem Zaun Das Ger t sollte ausschlie lich von qualifiziertem Personal ge ffnet bzw Sas m H ron repariert werden um das Risiko von elektrischen Schl gen zu minimieren Vor der Verwendung Bedienungsanleitung lesen Bitte entsorgen Sie dieses Ger t gem den Vorschriften in Ihrem Land ol Dt H Weist darauf hin dass das Elektrozaunger t schutzisoliert ist Wie funktioniert ein Elektrozaun Ein Elektrozaun besteht aus einem Elektrozaunger t und einem isolierten Zaun Das Elektro zaunger t versorgt die Zaunleitung mit kurzen Stromimpulsen Diese Impulse sind gekenn zeichnet von einer hohen Spannung und sehr kurzer Dauer weniger als 3 10000 Sekunden Trotz der kurzen Dauer ist ein Schock durch einen Elektrozaunimpuls sehr unangenehm und Tiere lernen sehr schnell Elektroz une zu respektieren Ein Elektrozaun ist nicht nur eine physische sondern vor allem eine psychologische Schranke Was sind die Vorteile eines Elektrozauns Ein Elektrozaun hat viele Vorteile gegen ber einem herk mmlichen Zaun e Das Aufstellen eines Elektrozauns erfordert weniger Arbeit und Materialaufwand als ein herk mmlicher Zaun e Flexibles ndern oder Hinzuf gen von Koppelweiden je nach Bedarf Schnelles und leichtes Aufstellen und Abbauen von tempor ren Z unen f r Portionsbewei
77. sol pour connecter le piquet avec la borne de contr le au poste de cl ture Veillez un bon contact et des connexions viss es 30 Contr le Si la premi re lampe s allume et si les petits chiffres sur l cran clignotes deux fois par seconde cela signifie que la tension et au dessus de 0 8 kV et qu une am lioration de la prise de terre est fortement conseill e Pour am liorer la prise de terre ajoutez des piquets ou des piquets plus longs L affichage de tension de prise de terre montre la tension sur les piquets quand le P poste et en mode w ou O La tension devrait toujours tre en dessous de 0 8 kV Si la tension est au dessus de 3 0 kY les chiffres clignotes pour montrer que la tension est insuffisante Tension terre Contr le de la batterie Lorsque l lectrificateur est connect une batterie et le bouton de r glage est mis E les indicateurs lumineux montrent le niveau de charge de la batterie Le contr le de la batterie fonctionne uniquement si une batterie acide plomb est utilis e M me si le poste est en mode contr le batterie M il met des impulsions sur la cl ture T moins Tension Etat de charge lt 17 0V Batterie surcharg e ou mauvaise batterie 000000008 12 6 17 0V Niveau de charge excellent 80 100 e aucune mesure n cessaire 0000000 12 3 12 6 V_ Niveau de charge tr s bon 50 80 00000 gt 12 0 12 33 V
78. ssleitungen und elektrische Weidezaundr hte d rfen nicht oberhalb von Freileitungen oder berirdischen Kommunikationsleitungen gef hrt werden Kreuzungen mit Freileitungen sind nach M glichkeit zu vermeiden Ist eine Kreuzung unum g nglich hat sie unterhalb der Stromleitung unter einem m glichst rechten Winkel zu erfolgen Werden Anschlussleitungen und elektrische Weidezaundr hte in der N he einer Freileitung installiert d rfen die Abst nde nicht geringer sein als die unten angegebenen Werte Mindestabst nde von Stromleitungen f r elektrische Weidez une Spannung Stromleitung Abstand lt 1 000 V 3m gt 1 000 lt 33 000 V Am gt 33 000 V 8m Werden Anschlussleitungen und elektrische Weidezaundr hte in der N he einer Freileitung installiert darf ihre H he ber dem Boden nicht mehr als 3 m betragen Dies gilt f r Elektroz une zu beiden Seiten der orthogonalen Projektion des u ersten Leiters der Stromleitung auf dem Boden in einem Abstand bis zu e 2m bei Stromleitungen mit einer Nennspannung nicht ber 1 000 V e 15m bei Stromleitungen mit einer Nennspannung ber 1 000 V Elektrozaunger te zur Versorgung von Elektrozaunanlagen auf der Weide d rfen nicht in feuergef hrdeten R umen wie Scheunen Tennen und Stallungen untergebracht werden Zur Verh tung von Blitzsch den muss vor der Einf hrung der Zaunzuleitung in das Geb ude in diese Zuleitung eine Blitzschutzeinrichtung Funkenstrecke mit Erdung eingebaut werde
79. st me de cl ture V rifiez la tension aux bornes de l lectrificateur avec un d tecteur de pertes un voltm tre num rique ou un testeur de cl ture Si la tension est inf rieure 6 kV faites v rifier votre appareil par un service apr s vente PATURA Verifiez la mise a la terre de votre electrificateur Pour un P4600 v rifiez que la tension de la terre sur l cran digital soit en dessous de 0 8 kV voir aussi page 30 Pour le P4500 suivez les instructions des chapitres Installation et v rification de la prise de terre la page 37 Contr lez l tat de votre cl ture Des fils de cl ture endommag s sont la cause la plus fr quente des baisses de tension Adressez vous votre fournisseur PATURA si la cl ture la mise la terre et l lectrificateur sont en bon tat mais que la tension reste inf rieure 4 kV Il vous aidera volontiers d terminer si l insuffisance de tension vient ventuellement d un agrandissement de la cl ture que vous auriez entrepris ces derniers temps ou de l tat du sol Comment localiser les pertes Nous vous recommandons le d tecteur de pertes PATURA pour localiser les pertes Cet appareil amp rem tre et voltm tre la fois vous permet de localiser rapidement les endroits o se produisent les pertes Vous pouvez aussi utiliser un voltm tre num rique PATURA ou un testeur de cl ture Utilisez des interrupteurs de courant pour stopper l alimentation lectrique de certaines
80. teile eines Elektrozauns Ein Elektrozaunsystem umfasst die folgenden Bestandteile e Elektrozaunger t e Erdungssystem Das Erdungssystem beinhaltet eine Reihe von Metallst ben die im Boden stecken und an den Erdungsanschluss am Elektrozaunger t angeschlossen sind e Zuleitungskabel Sie verbinden das Elektrozaunger t mit der Erde und dem Zaun e Isolierter Zaun Angeschlossen an den Zaunanschluss des Elektrozaunger ts Verschiedenste Zaunformen sind m glich siehe unten Hinweis Das Tier bekommt einen Stromschlag wenn es den Stromkreis zwischen Zaun und Boden schlie t Der Zaun besteht aus stromf hrenden Dr hten und erfordert leitf hige B den Elektrozaunger t stromf hrend stromf hrend lt Erdr ckleitung lt 7 Zaunvarianten Z une k nnen auf die Tierart und auf das verf gbare Material abgestimmt werden Besprechen Sie mit Ihrem PATURA H ndler welche L sung f r Sie am Besten geeignet ist Elektro Festz une PATURA bietet eine Reihe von Produkten f r die Errichtung von fest installierten Elektroz unen Mit Elektro Festz unen kann der Landwirt bei fachgerechter Montage e gr ere Fl chen einz unen e optimale Stromf hrung bei gro en L ngen erreichen e auf Jahre wartungsfreie Z une betreiben Mobile Elektroz une PATURA bietet eine Reihe von Produkten f r die Errichtung von versetzbaren Elektroz unen Mit einem mobilen Zaun der schnell und ei
81. tem Measure the voltage across the energiser terminals with a PATURA Fence Compass DVM or Fence Tester If the voltage is less than 6 kV request your PATURA service agent to check the energiser Check the energiser earthing For P4600 energiser check that the eath monitor voltage on the LCD display is below 0 8 kV see Earth monitoring on page 51 For the P4500 use the procedure described in Installing and testing an earth system on page 58 Check your fence system for faults The most common source of low voltage is faults on the fence line If the fence earth and energiser are in good condition and the voltage is still below 4 kV talk to your PATURA distributor They will help you identify whether recent extensions to your fence a poor fence layout or soil conditions may be causing inadequate voltage How do I locate faults The recommended tool for locating faults is the PATURA Fence Compass This combined voltage and current meter allows you to rapidly locate sources of current leakage Alternatively use a PATURA DVM or Fence Tester Use cut out switches to turn off the power to different sections of the electric fence If the voltage on the fence increases when a section of the electric fence is turned off then investigate that section for possible faults There are no lights flashing on the energiser Check the power supply Ensure that the power is switched on If the energiser still does not operate request your PATURA
82. tery lead into the Power input socket on the rear of the energiser Observe the correct polarity Remove the battery leads 1 Remove the eyelets or the battery clamps from the battery terminal 2 Hold the battery lead by the rubber sleeve and carefully pull it from the rear of the energiser by wiggling it gently Installing the energiser indoors The energiser must be installed indoors when being powered by mains line power Warning Do not use a mains line power extension lead Allow 25 mm of clear space around the mains line power adaptor To install the energiser indoors 1 Select a suitable installation site See Selecting a site for the installation on page 47 2 Mount the energiser on a wall Use the template printed on the back cover of this manual if required 3 Connect the Fence earth terminal green to NS the earthing system 4 P4600 only If earth monitoring is required 25mm clear space connect the Fence earth monitor terminal black to a separate earth stake For more Insulated high voltage cable HH information see Earth monitoring on page 51 5 Connect the Fence full voltage terminal red or the Fence half voltage terminal yellow to the fence 6 Connect the energiser to the mains line power using the mains power adaptor supplied Note If the energiser is being installed indoors it may be powered by a battery instead of the mains lin
83. tion 12 V Test batterie e jour lent nuit rapide e jour rapide nuit lent e demi puissance e pleine puissance Tension de sortie e maximale e 500 ohms nergie d impulsion maximale nergie stock e Dimensions I x h x p Poids Fiche technique P4500 P4600 12 V DC batterie 220 240 V AC 50 Hz secteur 10W 410 mA 530 mA Moyenne 530 mA Moyenne 330 mA 650 mA 9 5 kV 6 8 kV 6 2 J 9 0 J 250 x 240 x 90 mm 25 kg 44 ENGLISH Electric fencing and your PATURA energiser Congratulations on the purchase of your energiser from PATURA This product has been constructed using the latest technology and construction techniques It has been engineered to give superior performance and many years of service It is important to read these instructions carefully and thoroughly They contain important safety information and will assist you in ensuring that your electric fencing system gives maximum performance and reliability Warning e Switch the energiser off before installation or performing any work on the fence e Read all the safety considerations carefully See Safety Considerations on page 59 e Check your installation to ensure that it complies with all local safety regulations e Do not connect simultaneously to a fence and to any other device such as a cattle trainer Otherwise lightning striking your fence will be conducted to all other devices e Use only the mains line power adaptor or
84. ture de protection si n cessaire Utilisation de l adaptateur secteur et du c ble de connexion batterie Dans la livraison sont inclus un adaptateur secteur et un c ble de connexion pour le branchment sur batterie Avant de connecter l adaptateur ou le c ble assurez vous que le poste soit bien teint Branchement de l adaptateur 1 Branchez la prise de l adaptateur au dos du poste Veillez la bonne polarit 2 Branchez le poste la prise de courant Veillez ce qu il n y ait pas d autres objets dans un p rim tre de 25 mm autour de la prise D branchement de l adaptateur 1 D branchez l adaptateur de la prise de courant 2 Enlevez doucement la prise au dos du poste C ble de connexion batterie Le c ble est livr avec des jonctions annulaires qui sont gr ce leur bonne connexion lectrique id al pour un branchement permanent de la batterie Si votre batterie n est pas compatible avec des jonctions annulaires ou si vous changez souvent l emplacement de votre batterie nous vous conseillons d enlever les jonctions des c bles et de les remplacer par des pinces 1 Connectez la pince rouge avec le p le positif et la pince noire avec le p le n gatif 2 Branchez le c ble au dos du poste Veillez la bonne polarit D branchement du c ble 1 D connectez les jonctions ou les pinces 2 Enlevez doucement le c ble au dos du poste 27 Installation l int rieur L lectrificateur doit tre install l int
85. uand le poste est activ et que la fonction de la t l commande n a pas t activ e Pas d erreur La tension de la batterie est si faible que le poste ne peut pas travailler ou P4600 le poste a t teint par une t l commande La connexion avec la batterie n est pas bonne V rifiez les connexions et la tension de la batterie avec la fonction Contr le batterie voir aussi page 31 43 Maintenance L electrificateur b n ficie d une double isolation de protection c est dire qu il est quip de deux syst mes d isolation au lieu d une prise la terre Le c ble d un lectrificateur isolement de protection n est pas pr vu pour une mise la terre de l appareil et il ne faut surtout raccorder aucun autre dispositif de mise la terre l lectrificateur Son entretien exige un soin extr me et une connaissance parfaite du syst me et ne pourra tre effectu que par un personnel de maintenance form cet effet Les pi ces de rechange d un lectrificateur isolement de protection doivent tre absolument identiques celles qu elles remplacent Un lectrificateur de ce type porte la mention DOUBLE INSULATED double isolation ainsi que le symbole ci dessous qui peut galement appara tre sans mention l appareil en fin de vie ainsi que ses composants doivent tre rapport s un revendeur Patura a Alimentation lectrique Consommation 230 V Consomma
86. uel Dans le cas contraire vous pouvez aller voir un revendeur PATURA qui vous aidera 42 V lectrificateur s arr te parfois l improviste Il peut y avoir dans le voisinage une cl ture qui a le m me code Voir chapitre Changement du code de la t l commande page 35 pour changer le code Si il s arr te toujours veuillez aller voir un revendeur PATURA Recherche de pertes L affichage pour la tension de sortie grands chiffres clignote deux fois par seconde La premi re diode rouge est allum permanent et l affichage de la tension de terre petits chiffres clignote deux fois par seconde Le symbole de la batterie clignote deux fois par seconde La fl che droite dans l cran clignote deux fois par seconde Le poste n met pas d impulsions et la derni re diode verte clignote une fois par seconde Le poste n met pas d impulsions et la premi re diode rouge clignote deux fois par seconde La tension de cl ture est trop faible Il pourrait y avoir une erreur sur la cl ture Voir aussi Comment localiser les pertes 2 la page 42 La tension de la terre est trop importante Utilisez la fonction de contr le de prise de terre Voir page 30 La tension de batterie est trop faible Contr lez de suite la batterie avec la fonction de contr le Voir aussi page 31 Le poste cherche le signal d une t l commande Cela arrive chaque fois dans les 10 premi res minutes q
87. urage rationn Remarque Utilisez des fils suppl mentaires pour des esp ces animales plus petites ou plus sauvages Ajoutez si n cessaire un ruban plastique large ou une corde pour une meilleure visibilit de la cl ture avec les chevaux par exemple Installation et v rification de la prise de terre Choisissez un emplacement appropri pour votre prise de terre Cet emplacement doit remplir les conditions suivantes e Etre au moins 10 m tres de distance de toute autre prise de terre lignes t l phoniques ou lectriques e Etre prot g des animaux ou des v hicules qui pourraient endommager l installation e Etre facile surveiller pour assurer la maintenance e Avoir si possible un sol humide donc un endroit ombrag ou mar cageux La mise la terre ne doit pas tre faite obligatoirement proximit de l lectrificateur Enfoncez les piquets de terre PATURA compl tement dans le sol Utilisez un c ble isol haute tension pour effectuer le montage en s rie des piquets de terre avec la borne de terre de lectrificateur Veillez ce que le c ble soit suffisamment d nud pour obtenir une bonne connexion entre le fil et le piquet de terre Le tableau ci dessous montre le nombre de piquets de terre minimum de 1 2 m de longueur n cessaire pour une prise de terre efficace Il est cependant fr quent qu un sol sec ou mauvais conducteur vous oblige utiliser des piquets de terre de plus grande t
88. y comparing the voltage of the energiser s earth system with that of a separate earth stake Ensure the separate earth stake is at least 10 m 33 away from any other earth system including the energiser s main earth system Drive one 1 m earth stake into the ground Use high voltage insulated cable to connect the Fence earth monitor terminal with the separate earth stake Ensure good contact and that all connections are made using screws 51 Monitoring the earth If the first Indicator light is illuminated permanently and the earth monitor voltage on the LCD display small digits on top right flashes twice per second this indicates that the earth voltage is over 0 8 kV and that better earthing may be beneficial To improve the earth add more or longer earth stakes The small digits on the LCD display show the voltage going to the earth system when the selector switch is set to w m or The earth monitor should remain below 0 8 kV at all times If the earth monitor voltage is above 3 0 kV the numbers in the display flash to indicate that the earth is insufficient a Earth voltage Testing the battery voltage When the energiser is connected to a battery and the selector switch is set to Battery Test E the Indicator lights show the battery charge level The battery test is only relevant when a lead acid battery is used Note When the selector switch is set to Battery Test E the energiser pulses at slow speed and
89. zwei Isolationssysteme verwendet Im Stromkabel eines schutzisolierten Elektrozaunger ts ist keine Ger teerdung vor gesehen es sollte auch keine andere Vorkehrung zur Ger teerdung an das Elektrozaunger t angeschlossen werden Die Wartung eines schutzisolierten Elektrozaunger ts erfordert gr te Sorgfalt und genaue Kenntnisse des Systems und darf daher nur von ausgebil detem Wartungspersonal durchgef hrt werden Ersatzteile die in ein schutzisoliertes Elektrozaunger t eingebaut werden m ssen identisch sein mit den Teilen die sie ersetzen Ein schutzisoliertes Elektrozaunger t ist gekennzeichnet mit der Aufschrift DOUBLE INSULATION oder DOUBLE INSULATED schutzisoliert und oder dem Symbol unten E Technische Daten Stromversorgung P4500 P4600 12 V DC Batterie 220 240 V AC 50 Hz Netzteil Leistungsaufnahme bei 230 V Betrieb 10 W Stromverbrauch bei 12 V Betrieb e Batterietest 410 mA e Tag langsam Nacht schnell 530 mA Durchschnitt e Tag schnell Nacht langsam 530 mA Durchschnitt e Halbe Leistung 330 mA e Volle Leistung 650 mA Ausgangsspannung Ohne Last 9 5 kV e 500 Q 6 8 kV Max Impulsenergie 6 2 J Ladeenergie 9 0 J Abmessungen B x H x T 250 x 240 x 90 mm Gewicht 2 5 kg 93 24 FRANCAIS Les cl tures lectriques et votre lectrificateur PATURA F licitations pour l acquisition de cet lectrificateur PATURA Cet appareil est construit selon la technologie et les tech