Home
USER MANUAL
Contents
1. Identification code Description Notice Indicates situations that may result in damage to Electronic remote BRC7E530 Wireless remote equipment or property controller wireless controller to control cooling and heating each fan coil unit independently with Information This symbol identifies useful information but cooling and heating no hazardous situation warnings functionality Remark B Refertothe VRV Some types of danger are represented by special symbols system in the operation Electric current manual The function auto fan speed is not available Danger of burning or scalding Electronic remote BRC7E531 Wireless remote controller wireless controller to control cooling only each fan coil unit Other symbols independently with cooling functionality This part of the manual is intended for the installer of this only product Remark B Refertothe VRV system in the operation manual Before operating The function auto fan speed is not available 2 1 Check that you have all equipment and the Electronic remote BRC315D7 Wired remote corresponding documentation controller wired controller to control each fan coil unit Extra reguired eguipment independently with The fan coil unit must be used in combination with additional cooling and heating equipment functionality This equipment must be bought separately and is required to operate Central remote DCS302CA51 Remote controller for the fan coil unit safely and
2. clarification Glossary on page 4 Important This user manual does not explain how to operate your fan coil unit You can only operate your fan coil unit by means of a controller Therefore the operating instructions are included in the controller box Keep this user manual close to hand It may come in handy later The original documentation is written in English All other languages are translations of the original documentation User manual DAIKIN PNT Fan coil units 4PW65028 1A 05 2011 Before operating 1 3 1 Meaning of warnings and symbols An overview of the types that are available Warnings in this manual are classified according to their severity and Decoration panel Identification code Description probability of happening i i Decoration panel BYFQ60B Decoration panel for Danger Indicates an imminently hazardous situation the fan coil unit which if not avoided will result in death or serious injury Panel spacer KDBQ44B60 Decorative spacer to fill the gap between panel and unit when Warning Indicates a potentially hazardous situation which the height of tte _ if not avoided could result in death or serious injury suspended ceiling is too small Caution Indicates a potentially hazardous situation which Mandatory eguipment Each fan coil unit must be connected to at if not avoided may result in minor or moderate injury least one ofthe listed controllers gt D gt Controllers
3. direct sunlight from entering a room during cooling operation by using curtains or blinds B Ventilate the room regularly Using the unit for long periods of time reguires attentive ventilation of the room B Keep doors and windows closed when the unit is in operation If the doors and windows remain open air will flow out and decrease the effect of cooling and heating B Never place objects near the air inlet and the air outlet of the unit It may reduce the effectiveness or cause the unit to stop Turn off the main power supply switch when not using the fan coil unit for long periods of time Electricity is consumed so long as the switch is on Turn off the main power supply switch in order to save energy Fully use the function of air flow direction adjustment if available As cold air gathers on the floor and warm air gathers against the ceiling it is recommended to set the air flow direction during cooling operation parallel to the ceiling and to set it downwards during heating operation Be sure that you do not direct air flow on to the inhabitants of the room User manual 3 DAIKIN FWF Fan coil units 4PW65028 1A 05 2011 4 Clean your fan coil unit To clean the outside of your fan coil unit 1 Switch off the fan coil unit 2 Clean the outside of the fan coil unit with a soft cloth Notice Do not pour any liquid on the fan coil unit This could damage the components inside it Never clean your fa
4. DAIKIN USER MANUAL FWF02B7TV1B FWF03B7TV1B FWF04B7TV1B FWF05B7TV1B FWF02B7FV1B FWF03B7FV1B FWF04B7FV1B FWF05B7FV1B _ mm VER Ad 1111111711177 fi AS OOTAN Introduction Table of contents 1 Introduction 1 1 About fan coil units 1 2 About your fan coil unit 1 3 About this document 1 3 1 Meaning of warnings and symbols 2 Before operating 2 1 Checkthat you have all eguipment and the corresponding documentation 2 2 Readthe safety precautions Tips for optimal operation Clean your fan coil unit Solve problems with your fan coil unit Dispose of your fan coil unit Glossary NO A A amp fs ps pa VW w NIN NAA al Annex Handover of the installation to the user 1 Introduction Thank you for purchasing this DAIKIN fan coil unit 1 1 About fan coil units A fan coil unit provides heating and or cooling to individual spaces lt creates a comfortable environment in both commercial and residential applications Fan coil units are widely used for the air conditioning of offices hotels and houses The main components of fan coil units are B afan NW aheatexchanger The heat exchanger receives hot or cold water from a heating or cooling source DAIKIN offers a wide range of fan coil units for both concealed and exposed applications Contact your installer for a list of related products 1 2 About your fan coil unit You have purchased the FWF model fan coil unit The mode
5. an electrical and electronic product It is marked with the symbol illustrated in figure WEEE symbol on page 4 This symbol means that your fan coil unit should be recycled and not disposed of in unsorted municipal waste To dispose of your fan coil unit contact your installer The installer and gualified instances will HW dismantle the fan coil unit M re use recycle and recover parts of the fan coil unit N Warning Never dismantle the fan coil unit yourself DAIKIN and the environment thank you 7 Glossary Applicable All international European national and local legislation directives laws regulations and or codes which are relevant and applicable for a certain product or domain Circuit Safety device used in electrical installations to breaker fuse prevent electric shock Are any doors and windows Close doors and windows PA Installer Technical skilled person who is qualified to install fan coil units and other DAIKIN products Is the fan coil unit running at low Select medium speed or high speed speed Are the air filters dirty Contact your installer or service Service Qualified company which can perform or company company coordinate the required service to the fan coil unit Your fan coil unit leaks water Shut down the unit and contact your installer or service company FWF DAIKIN User manual Fan coil units 4PW65028 1A 05 2011 Annex Handover of the installation to the user Annex Han
6. comfortably controller centralized control of a gt gt N Overview of additional eguipment reguired all connected units m decoration panel Intelligent touch DCS601C51C Advanced remote B controller controller controller for centralized control of all connected units Unified ON OFF DCS301BA51 Remote controller to controller switch all connected units ON or OFF FWE DAIKIN User manual Fan coil units 4PW65028 1A 05 2011 Before operating Extra optional eguipment Optionally you can buy additional eguipment for your fan coil unit to extend the life of your product increase the level of automation and improve its ease of use Overview of the optional additional equipment for your fan coil unit An overview ofthe types that are available B air handling options sensor timer valves electronic circuits PCB Air handling options Identification code KDBH44BA60 Blocking parts to close one or more air outlets of the fan coil unit Long life KAFQ441BA60 High quality filter replacement filter KDDQ44XA60 Kit which can be connected to the ventilation system in order to supply fresh air to the fan coil unit Description Sealing member of air discharge outlet Fresh air intake kit Sensor Identification code Remote temperature KRCSO1 1 sensor Description Replacement sensor to measure temperature remotely from a location other than that in which the controller i
7. dover of the installation to the user Tick Y when checked Ensure that the user has a printed version of the user To be filled in by the installer once the test run is finished and the fan manual and the installation manual and ask him her to coil unit s operate s properly keep it for future reference ick Y M l WIRD COSCHE Explain the user how to properly operate the system and Explain to the user what system is installed on site what he she has to do in case of problems Complete the ID cards below for each installed fan coil unit This information may be useful for the user in future servicing Fill in the place of installation room the model I Show the user what maintenance jobs he she has to do in name see nameplate of the fan coil unit and list the relation to cleaning the unit optional eguipment which is installed Date Signature Fan coil unit 1 Fan coil unit 2 Place of Place of installation installation Pt PE 7 Optional equipment Optional eguipment Fan coil unit 3 Fan coil unit 4 Place of Place of installation installation Optional equipment Optional equipment Fan coil unit 5 Fan coil unit 6 Place of Place of installation installation Modelname Wodetname Optional equipment Optional equipment Fan coil unit 7 Fan coil unit 8 Place of Place of installation installation oder name Wodername Optional equipment Optional equipment User
8. fan coil unit according to the documentation Precautions for installation The installer should install and connect your fan coil unit as described in the installation manual Please note that the installer can only install your fan coil unit NW ina concealed ceiling B in perfect condition Precautions before operating Only operate your fan coil unit after it has been installed by a licensed installer Verify that the installation has been completed by checking that the Annex Handover of the installation to the user on page 5 has been filled in completely Precautions for operating Only operate a fan coil unit if you are fully alert and aware Fan coil units are not intended for use by persons with reduced physical sensory or mental capabilities or those who have not used the fan coil unit before including children When these persons want to use the fan coil unit the person responsible for their safety must supervise them or instruct them in the use ofthe fan coil unit Supervise children to ensure that they do not play with the fan coil unit If you feel unsure about operating the fan coil unit contact your installer for advice and information wo Tips for optimal operation Adjust the room temperature properly for a comfortable environment Avoid excessive heating or cooling Notice that it may take some time for the room temperature to reach the set temperature Consider using the timer setting options B Prevent
9. l identification code means FW F 02 B V1 FW Water fan coil unit F Subclass Cassette F 2x2 02 Total cooling capacity kW B Major model change 7 Minor model change Coil type T 2 pipe F 4 pipe V1 1 phase 50 Hz 220 240 V B Produced in Europe The following models are available B FWFO02 03 04 05B7TV1B 2 pipe fan coil units have a single circuit heat exchanger The device can be used for either cooling or heating B FWFO02 03 04 05B 7FV1B 4 pipe fan coil units have a double circuit heat exchanger The units can be connected to both cooling and heating systems Use this type if you have a separate source for cooling and for heating 1 3 About this document This document is a user manual It is written for the person who owns or operates this fan coil unit It provides information on the product itself Introduction on page 1 what you should do before you operating the fan coil unit Before operating on page 2 B what you should do for optimal operation of your fan coil unit Tips for optimal operation on page 3 B how you should clean your fan coil unit Clean your fan coil unit on page 4 B what you should do when there is a problem with your fan coil unit Solve problems with your fan coil unit on page 4 B how you should dispose of your fan coil unit Dispose of your fan coil unit on page 4 terms that have been used in this user manual that may need
10. manual DAIKIN EWE 5 Fan coil units 4PW65028 1A 05 2011 Copyright 2010 Daikin DAIKIN EUROPE N V Zandvoordestraat 300 B 8400 Oostende Belgium 4PW65028 1A 05 2011
11. n coil unit with NW any aggressive chemical solvent B water hotter than 50 C For maintenance of your fan coil unit contact your installer or service company 5 Solve problems with your fan coil unit When your fan coil unit does not function well you can try to solve any problem with the corrective actions in this chapter If the problem persists or is not addressed in this chapter contact your installer or service company Your fan coil unit does not function If your fan coil unit does not function Check If yes Has the fan coil unit been Switch the fan coil unit ON switched OFF Is there a power failure Restore the power supply Has the circuit breaker fuse Contact your installer or service been tripped company Your fan coil unit does not cool or heat well If your fan coil unit does not cool or heat well Check If yes Is there an obstacle near the air Remove the obstacle inlet or air outlet Clean your fan coil unit 6 Dispose of your fan coil unit Your fan coil unit was designed to be environment friendly DAIKIN has complied with the standards for environmentally friendly disposal This means that you have to dispose of your fan coil unit in accordance with the applicable legislation By ensuring this product is disposed of correctly you help to prevent potential negative consequences for the environment and human health EE Fig 6 1 WEEE symbol Your fan coil unit is categorized as
12. s installed Identification code Description DST301BA51 Controller with schedule timing functionality Identification code Description EKMV2C09B7 Electronic 2 way valve to control the water supply EKRP1C11 EKMV3C09B7 Electronic 3 way valve to control the water supply EKRP1C11 Identification code EKRP1C11 Schedule timer Valves 2 way valve ON OFF type 3 way valve ON OFF type Electronic circuits Valve control PCB Description Mandatory electronic circuit when 2 way or 3 way valve is used Optional PCB for EKFCMBCB7 Electronic circuit with Modbus connection Modbus interface connections Wiring adaptor for KRP4A A 53 electrical appendices KRP2A52 Electronic circuit with additional connections for external input output signals Remote ON OFF EKROROA Connection to control and Forced OFF kit the ON OFF operation remotely 2 2 Readthe safety precautions Your fan coil unit is built to meet all recognized technical requirements Operate your fan coil unit according to the instructions in the included documentation and the manuals of the additional equipment e g controller Any other usage is considered as improper and may result in property damage serious physical injuries or death Resulting damage caused by improper use is the sole responsibility of the user and the user alone To prevent any risk B carefully read the safety precautions NW operate your
Download Pdf Manuals
Related Search
Related Contents
Manual del usuario Sablé industries inc. 100 L`amprii Avenue, Suite 5, Kitchener 取扱説明書 - TOEX Philips DVP3520K User's Manual ISTRUZIONI PER L`USO E L`INSTALLAZIONE Scott 2011 bike owners manual genius KVM Expertise - G&D-North America Inc. Manual en Español-English Operating Instructions EEPM__EPM programmer Osram HALOSTAR STAR Copyright © All rights reserved.