Home
Instruction Manual and Installation Instructions LAS
Contents
1. gt Q J J ZHOS A0EZ AeL 8Svl v l M M S NS ON NA N CN O08 8 P8 08 8N C C C C E C C C C c uvss mpv ad d lyse Kup HOPI 17988 TWH ILGrrvrros 7 fo a MA ON Mob MOMS NL C C C C C C C C 810 523 BA EN 1 LAS 1218 2 battery charger Living area and start battery connectors Battery selector switch Indicator lamps for charging cycle Installation feet Mains cable with earthing type plug or WAGO connector optional This device is not intended to be used by persons including children with limited physical sensory or mental aptitude or lack of experience and or knowledge unless they are supervised by a person responsible for their safety or have received instruction from this person as to how the device is used Children are to be supervised so as to ensure they do not play with the device This device is intended for installation into a vehicle Date 06 11 2014 3 Instruction Manual and Installation Instructions LAS 1218 2 The LAS 1218 2 battery charger is for charging suitable
2. Schaudt GmbH Elektrotechnik und Apparatebau PlanckstraBe 8 88677 Markdorf Germany Tel 49 7544 9577 0 Fax 49 7544 9577 29 www schaudt gmbh de 810 523 BA EN Instruction Manual and Installation Instructions Oo O gygy uu 50 00000000 ari ef Sla m e a ENS pr es W a bes I EETA iy ge CI m Eg eat D Iia SR gag CI E ge LIO 2 co FD Jr 8 aw Ys Cri gt 8T i JUUUUUUUSIUUUUUUUUU cH Ee p ern O ja E B yernce fi gt NAA AAANnARRInN NO AAANAND CI gt amp D m D Haupteden H UU co volladen o i D am i H5 erhanungstaden H UULUULUU AJA Q annannan 0008080 O O LAS 1218 2 Battery Charger Table of contents 1 Instruction manual 0 cece ete ee eee 1 1 Safety information 00 e cee ees 1 2 Introduction 2 1 ee n 1 3 Operatlon uio prete Rer Edad re EE E 1 4 Maintenance ssseeseee e n 2 Installation instructions 0 cee eee 2 1 IntroductiOTl is ews sekia a exi e REREreztrE x R4 rex 2 2 Mechanical installation 00 0 ccc eee eee eee 2 3 Electrical connection 6 0 cee eee eas 2 4 Initlal Se
3. current of 3A The final charge voltage is 14 1 V Operation as Output current 18 A connection of a battery not required power supply unit Output voltage 14 3V 13 8V suitable for 12V consumers smoothed DC voltage 2 5 3 Environmental parameters Operating temperature 20 C to 45 C Storage temperature 20 C to 70 C Humidity Operation in dry environment only CE CE mark 2 6 Storage Packaging Transportation Only transport and store the battery charger if the packing is suitable and ambient conditions are dry No part of this manual may be reproduced translated or copied without ex press written permission 18 Date 06 11 2014 810 523 BA EN Manufacturer Address Additional charger As a standalone device C Customer service address Send in the device 810 523 BA EN Instruction Manual and Installation Instructions LAS 1218 2 Appendix EC Declaration of Conformity Schaudt GmbH hereby confirms that the design of the LAS 1218 2 battery charger complies with the following relevant regulations e EC Low Voltage Directive 73 23 EEC edition with modifica tions from 22 07 93 e Directive on Electromagnetic 89 336 EEC with modification Compatibility 92 31 EEC e Norms and technical specifications applied in particular DIN EN 60335 1 1994 A11 A1 A12 A18 A14 DIN EN 60335 2 29 1996 A11 DIN EN 50081 1 3 1993 DIN EN 50082 1 3 1993 DIN EN 61000 3 2 2000 The o
4. terminal of LAS 1218 2 living area battery Flat push on contact 6 3 x 0 8 Fig 3 Pos 1 e terminal of LAS 1218 2 Flat push on contact 6 3 x 0 8 Fig 3 Pos 2 e MNL connector view X Fig 3 Pos 4 5 or Minifit connector on elec troblock base auxiliary charger see also instruction manual for electroblock Date 06 11 2014 11 Instruction Manual and Installation Instructions LAS 1218 2 1 1 1 2 Direct connection to living area and starter battery For this type of connection there is a direct connection between the LAS 1218 2 battery charger and the two motorhome batteries or also only one battery e g for a caravan Deliverables The following parts are supplied under item number 999 086 for this applica tion Fig 4 Connector set deliverables Pos Qty Name 1 1 LAS 1218 2 battery charger 2 7 Flat push on contacts 6 3 x 0 8 blue 3 3 Ring terminal 1 2 5 mm M6 4 3 Ring terminal 1 2 5 mm M8 5 2 Fuse holder for flat vehicle fuse 6 1 Flat vehicle fuse 20A 7 1 Flat vehicle fuse 10 A The connector set Pos 2 to 6 is required to connect the LAS 1218 2 bat tery charger to up to two batteries A The length of the line to the starter battery may not exceed 4 m supply and return lines together for a cable cross section of 2 5mm see also table on page 10 12 Date 06 11 2014 810 523 BA EN Instruction Manual and Installation Instructions LAS 1
5. the 230V supply has been discon nected e Never try to start the device using a defective mains cable or with a faulty connection e Never carry out maintenance work on live devices e Ensure proper electrical connections are made e Ensure correct electrical fuses are used e The mains connection line may only be replaced by an authorised cu stomer service department or by qualified persons Date 06 11 2014 810 523 BA EN 1 2 A Instruction Manual and Installation Instructions LAS 1218 2 WARNING Hot components Burns e Only change blown fuses when the device is completely de energised e Only replace blown fuses once the cause of the fault has been identi fied and rectified e Never bypass or repair fuses e Only use original fuses rated as specified on the device or in these in structions e Therear of the device may become hot during operation Do not touch e Never store heat sensitive objects close to the device e g tempera ture sensitive clothes if the device has been installed in a wardrobe Introduction ie OOO eee Es O v V JuuoM non gt c 8I2L SV1 T eueneg T ouogeg 1euems A Bki Saure LI Y Blei Gel ueAM Sueneg Hauptladen Volladen Erhaltungsladen v J
6. 18 2 flat push on contact 6 3 x 0 8 to F4 flat push on contact 6 3 x 0 8 14 Date 06 11 2014 810 523 BA EN Instruction Manual and Installation Instructions LAS 1218 2 F4 flat push on contact 6 3 x 0 8 to battery terminal ring terminal M6 or M8 gt LAS 1218 2 to additional battery connection e terminal of LAS 1218 2 flat push on contact 6 3 x 0 8 e terminal of battery ring terminal M6 or M8 Label the additional fuse with sticker F4 additional battery ego vu Y Y He rw DT LT vy 8 L KI L LAS 1218 2 T aL 230 V Fig 7 Example circuit diagram inverter installation grey background LAS 1218 2 battery charger with connector set Pos Name Pos Name DC AC Inverter F4 Fuse additional battery charge current DT LT DT or LT control and display pa G Vehicle alternator higher rating nel in the vehicle EBL Electroblock G1 Starter battery Fa Fuse EBL charge current for starter G2 Living area battery battery Fb Fuse EBL charge current for living G3 Additional battery area battery F1 Fuse starter battery cut off relay K1 Cut off relay starter battery additio nal battery F2 Fuse cut off relay additio
7. 218 2 ips ML cc LAS 1218 2 Batterie Wahl 5 IUoU g E O a as 3 O o6 O 3 c d Wohnr Starter 1 d s 2 a UN Batterie 5 m 2 8 E gt d ES OOO em Y CY C coy CY C Y i Y CY CY lt x l O N j 3p 4 Fig 5 Connection Diagram LAS 1218 2 Battery Charger to Living Area and Starter Battery Fuse F1 1 2 FuseF2 3 Living area battery 4 Starter battery terminal of LAS 1218 2 living area battery flat push on contact 6 3 x 0 8 to F1 flat push on contact 6 3 x 0 8 F1 flat push on contact 6 3 x 0 8 to terminal of living area battery ring terminal M6 or M8 terminal of LAS 1218 2 starter battery flat push on contact 6 3 x 0 8 to F2 flat push on contact 6 3 x 0 8 gt F1 flat push on contact 6 3 x 0 8 to terminal of starter battery ring terminal M6 or M8 Connection LAS 1218 2 to living area or starter battery e terminal of LAS 1218 2 flat push on contact 6 3 x 0 8 e terminal of battery ring terminal M6 or M8 Label the two fuses with stickers F1 living area battery and F2 star ter battery A The negative terminal Pol of the li
8. LAS 1218 2 The connector cable Pos 2 or 3 is required to connect the LAS 1218 2 battery charger to the electroblock An additional fuse is not required as there is already one integrated in the electroblock You only have to check if the fuse is fitted and if it complies with the fuse rating on the label The battery charger is connected to the electroblock with a 2 pin charger ca ble Other lengths are available on request A connection to the starter battery is not required because the electroblock already has the start battery recharge module LAS 1218 2 Batterie Wahl 5 Caer IUoU g 3 O aT E a O 0 0 c 9 Wohnr Starter 1 4 S 2 a T Batterie zo S 2 E gt d ES Hu OOO Y Y ry Y y P Fs ae CY x p CY e s AYY x 3 fara UT i 4 5 X Fig 3 Connection Diagram of LAS 1218 2 Battery Charger on Electroblock 1 Flat push on contacts 6 3 x 0 8 red cable 2 Flat push on contacts 6 3 x 0 8 brown cable 3 notassigned 4 Living area battery red 5 Negative battery brown 2 pin charger cable LAS 1218 2 to electroblock connection e
9. batteries during 230V operation or supplying 12V consumers without connected battery with power The device is a primary controlled switch mode power supply unit This mo dern switching technology achieves high charging performance at a compact size and low weight The battery charger can be used e asa battery charger for charging the living area battery and for re charging a connected starter battery e asan additional charger for charging the living area batteries having a higher capacity which match every Schaudt electroblock with a type LAS charger module e asa power supply unit up to 18 A for the 12V consumers connected No battery is required here 1 3 Operation 1 3 4 Controls and indicator lamps The device has no controls which need to be used on a day to day basis The battery selector switch need only be set correctly on initial use and for a change of battery Battery selector switch A DANGER AN Risk of explosion e An incorrect battery selector switch setting poses a risk of explosion due to the formation of electrolytic gases A ATTENTION e An incorrectly set battery selector switch damages the living area bat tery e Disconnect the battery charger from the mains before adjusting the battery selector switch Changing the battery gt Batteries may only be replaced by qualified personnel Follow the battery manufacturer s instructions Charging unsuitable types of battery may damage them beyo
10. e battery supplier and the charging parameters of Schaudt equipment The charging parameters are specified in the operating and installation instructions Starting up the system Ensure that the battery is connected correctly or all if more than one is available 230V mains supply must be connected to vehicle Power on the electrical system of the vehicle e g power on 12V main switch on the switch panel see instruction manual for switch panel con nected 230 V mains cable of the LAS 1218 2 charger must be connected the charger does not have its own mains switch gt Check whether the batteries are being charged display on the battery charger Technical details Mechanical details ca 90 x 148 x 248 H x W x D in mm including attachment feet 1 0 kg Polyamide blue similar to RAL 5010 Electrical details 230 V AC voltage 10 47 63 Hz sinusoidal protection class 19A 6 cell lead acid or lead gel batteries 55 Ah and above approx 0 3 mA Conditions for the measurement e approx 10 min after mains isolation without mains connection e with battery connected battery voltage 12 6V A maximum of 9096 of the nominal current of the relevant fuse may be drawn 12V outputs Date 06 11 2014 17 Instruction Manual and Installation Instructions LAS 1218 2 Battery charging via Living area battery mains connector Charging curve IUoU Final charging voltage 14 3 V Charge current 18 A in th
11. e entire mains voltage range electronically limited minus the charge current into the vehicle battery Voltage for float charge 13 8 V with automatic switchover New charge cycle with battery voltage below 13 8 V Switchover to main charging with approx 5 seconds delay Solar chargin D m Main charge Full charge Float charge l Uo 13 8 4 h with lead acl wi LI LY 16 h with lead gel Time Fig 9 Example of the charge voltage behaviour with the LAS 1218 2 battery charger Main charge with maximum 18 A charging current electronically limi ted up to final charging voltage Start of charge also for totally dischar ged batteries Uo Automatic changeover to full charge with constant 14 3 V The duration of the full charge phase depends on the type of battery and is configu red on the device Lead acid batteries 4 hour lead gel batteries 16 hours U Automatic changeover to trickle charge with constant 13 8V In the trickle charge phase the voltage at the output of the charging module is constant The battery is now fully or virtually fully charged Start of a new charging cycle by switching over to main charge if the battery voltage falls below 13 8 V for more than 5 seconds when loaded Start of charge also for totally discharged batteries Battery charging of the For mains operation the starter battery is also charged with maximum starter battery charge
12. et GE I I D n as na CH I J I imu 83 cr 4s l CH I I LIO est cu a s H8 mn en I J I CD VUUUUUUDUUD v ZHL cH EA EI LA SEALED IA br BB bb e mO O 80 cec a Flat pins 6 3 x 0 8 m 90 4 x attachment in the insulation housing holes 24 5 Fig 1 Dimension diagram of LAS 1218 2 battery charger dimensions in mm 2 2 2 Fuse holder For applications that require one or two additional fuses see sections 1 1 1 2 and 1 1 1 3 for example fuse holders from the connector set must be installed gt Determine the place of installation of the fuse holder s The place of in stallation must be in the direct vicinity of the corresponding battery Drill a hole 8mm in diameter for every fuse holder Lock the fuse holder into place in the drillhole Electrical connection The battery charger connection is established in the following order 1 All connections on the front panel of the battery charger 2 Battery lines to the battery terminals 3 230V mains connection Disconnect in the reverse order Connections on the front panel A ATTENTION Short circuits Damage to the battery charger or fire damage to cable e To protect the supply lines in the event of a short circuit connect the fuses directly to the positive terminal of battery Date 06 11 2014 Instruction Manual and Installation Instructions LAS 1218 2 Fusing 1 1 1 1 Auxiliary charger Deliverables 10 Select cable cross sections
13. i i ir bee vaeed V IER RPERPERPTreBP Bre LUPLRSRTISS 2 5 Technical details 0 0 ccc eee ete eee 2 6 Storage Packaging Transportation Append icerum casa ee bears ent eat we Peed eee tenes Date 06 11 2014 P EUR Instruction Manual and Installation Instructions LAS 1218 2 SCH UDT Instruction Manual Safety Information Meaning of safety symbols A DANGER Failure to heed this warning may result in death or serious injury A WARNING Failure to heed this warning may result in personal injuries A ATTENTION Failure to heed this warning may result in damage to the device or connec ted consumers General safety information The device is state of the art and complies with approved safety regulations Nonetheless personal injuries or damage to the device may occur if the sa fety instructions contained herein are not followed Ensure that the device is in perfect working order before use Any technical faults which may impact personal safety or the safety of the device must be rectified immediately by qualified personnel A DANGER 230V mains voltage carrying parts Danger of death due to electric shock or fire e The electrical system of the motorhome or caravan must comply with current DIN VDE and ISO regulations e Connect devices rated at 230V to the 230V supply in line with national installation regulations e Never modify the device e Only carry out electrical work once
14. in line with EN 1648 1 2 The maximum current load must not exceed 9096 of the individual fuse rating Recommended cable cross sections Line length Cable cross section sum of supply and return lines Upto4m 2 5 mm Up to 8 m only for living area battery 4 0 mm Up to 12 m only for living area battery 6 0 mm Fuse the supply lines as follows e with 1 5 mm cable cross section 10A e with 2 5 mm cable cross section or greater 20A Connection as for auxiliary charger to the electroblock The LAS 1218 2 battery charger can also be used as an auxiliary charger for a Schaudt electroblock Suitable for use here are all Schaudt electroblocks that include the LAS charger module and have the 2 pin MN connector e g EBL 99 or Minifit connector e g EBL 220 for an auxiliary charger See the instruction manual for the electroblock Suitable accessories The following parts are supplied for this application e ltem number 999 085 with MNL connector e ltem number 999 161 with Minifit connector Fig 2 Connector set deliverables Pos Qty Name 1 1 LAS 1218 2 battery charger earthing type plug connection example 2 1 Connector cable 1 7m with Minifit connector 3 1 Connector cable 1 7m with MNL connector Pos 2 and 3 as an alternative depending on electroblock to be connected Date 06 11 2014 810 523 BA EN Fusing Instruction Manual and Installation Instructions
15. nal battery LAS 1218 2 Battery charger F3 Fuse inverter supply LAS Charger module of electroblock 810 523 BA EN Date 06 11 2014 Instruction Manual and Installation Instructions LAS 1218 2 2 3 2 Mains connection A DANGER AN 230V mains voltage carrying parts Danger of death due to electric shock or fire e Only carry out electrical work once the 230V supply has been discon nected Mains connection The mains must be connected as follows e toainsulated distribution unit with protective contact e toasocket with protective contact isolated ground or suitable plug connector from WAGO depending on LAS 1218 2 variant The power cord must be of type HO5VV F 3x1 5 The mains cable must have a strain relief where required 2 4 Initial use 2 4 1 Checks prior to initial use Before starting up gt Ensure that the batteries are connected properly only for initial use ope ration without battery is possible in general 2 4 2 Setting battery type Establish battery type A DANGER AN Incorrect setting of the battery selector switch Risk of explosion from build up of electrolytic gas defective battery defec tive battery charger or as a result of too high a battery operating tempera ture above 30 C e Move the battery selector switch to the correct position e The battery charger is to be used solely for connecting to the 12V power supply with rechargeable 6 cell lead gel or lead acid batte
16. nd repair It is possible to swap lead acid batteries for lead gel batteries Given the lack of ventilation options within the vehicle changing from lead gel to lead acid batteries is not possible without additional overhead Ask your dealer for advice The switching option provided by the battery selector switch ensures opti mum charging of the two battery types lead gel and lead acid The switch must be set to the correct battery type lead acid or lead gel 4 Date 06 11 2014 810 523 BA EN Main charge Full charge Trickle charge e 1 3 2 Flat vehicle fuses 810 523 BA EN Instruction Manual and Installation Instructions LAS 1218 2 Use a thin object e g a ballpoint pen cartridge to move the battery selec tor switch A Suitability must be checked on a case by case using specifications from the battery supplier and the charging parameters of Schaudt equipment The charging parameters are specified in the operating and installation instructions Setting lead gel battery Set the battery selector switch to Lead gel Setting lead acid battery Set the battery selector switch to Lead acid If the battery charger is used to supply 12V consumers without connec ted battery with power the battery selector switch must be set to Lead acid The indicator lamps on the front of the battery charger show the current charging phase This indicator lamp lights up yellow in the Hauptladen Main cha
17. rge phase This indicator lamp lights up yellow in the Vollladen Full charge phase This indicator lamp lights up green in the Erhaltungsladen Trickle charge phase A If the batteries are totally discharged indicator lamp Erhaltungsladen Trickle charge or Volladen Full charge may light up for a while before the main charging phase begins System faults A fault in the power supply system is usually caused by a blown fuse Please contact our customer service department if you are unable to rectify the fault using the following table If this is not possible e g if you are abroad you can have the battery char ger repaired at a specialist workshop Please note that the warranty beco mes void if incorrect repair work is carried out Schaudt GmbH cannot ac cept liability for any damages resulting from such repairs Date 06 11 2014 5 Instruction Manual and Installation Instructions LAS 1218 2 Faut Possecmae Remedy Living area battery is not charged during 230V operation battery voltage continuously less than 13 3V Living area battery is overcharged during 230V operation battery voltage continuously greater than 14 5V Starter battery is not charged during 230V operation battery voltage continuously less than 13 0V 12V power supply in the living area does not work when the battery charger is being used as a power supply device The Volladen Full charge indicator lamp does no
18. ries Do not use any unsuitable battery types Store batteries in a place with adequate ventilation or provide integrated ventilation Follow the instructions provided by the battery manufacturer lead acid lead gel Batterie Wahl o 5 D c H88888 B888888 S S S LAS 1218 2 Batterie Wahl E I I S Baterie Baterio t m 3 T T a fni a p I E E d Q Q 888888 AHAAAA ETT Fig 8 Battery selector switch lead gel lead acid battery 16 Date 06 11 2014 810 523 BA EN 2 4 3 2 5 2 5 1 Dimensions Weight Housing 2 5 2 Mains connection Current consumption Suitable batteries Standby current from living area battery Current carrying capacity 810 523 BA EN Instruction Manual and Installation Instructions LAS 1218 2 gt Disconnect the battery charger from the mains before moving the battery selector switch gt Move the battery selector switch see Fig 8 into the correct position using a thin object such as a ballpoint pen e Lead gel battery Move the battery selector switch to Lead gel e Lead acid battery Set the battery selector switch to Lead acid gt Re check that the battery selector switch is set correctly for the type of battery used A Suitability must be checked on a case by case using specifications from th
19. riginal EC Declaration of Conformity is available for reference at any time Schaudt GmbH Elektrotechnik amp Apparatebau PlanckstraBe 8 88677 Markdorf Germany Accessories Suitable connector cable MNL or Minifit to Schaudt eletroblock Connector set with fuse holders and connector material Customer service Schaudt GmbH Elektrotechnik amp Apparatebau PlanckstraBe 8 D 88677 Markdorf tel 49 7544 9577 16 email kundendienst schaudt gmbh de Office hours Mon to Thurs 08 00 12 00 13 00 16 00 Fri 08 00 12 00 Returning a defective device Fill in and enclose the fault report see Appendix D Send it to the addressee free of charge Date 06 11 2014 19 Instruction Manual and Installation Instructions LAS 1218 2 D Fault report In the event of damage please return the defective device together with the completed fault report to the manufacturer Device type Item no Vehicle Manufacturer Model Own installation Yes No Upgrade Yes No LJ Following fault has occurred please tick Electrical consumers do not work which please specify below Switching on and off not possible Persistent fault Intermittent fault loose contact Other remarks 20 Date 06 11 2014 810 523 BA EN
20. stallation Its cross section is based on the size and average temperature of the place of installation Minimum clearance Keep a minimum clearance to the surrounding fixtures and fittings e Maintain a gap of at least 5cm on all sides except mounted side e Whilst in operation the ambient temperature must not exceed 40 C measured 2 5 cm away from the sides of the device Fitting gt Screw the battery charger onto a firm flat base with four screws 5mm diameter 8 Date 06 11 2014 810 523 BA EN Instruction Manual and Installation Instructions LAS 1218 2 247 5 2 3 Connection sequence Disconnecting 2 3 1 A 810 523 BA EN 163 5 i S i HHHHHH H Z i I I I NS QO0nnnnn CI uepegBumpua O CI I I I CI CI I I LB EE cH v O cn I I FI IcT uepepdnen O O I H mm e cns un I I N N D JUUUUUUUUESUUDUUUUU cni Ej cH EE fail PT g I I Y qu LI nnnnnnn EA Nn Q0nmnmn CE le CE I J I LI ak CI g
21. t light up despite several hours of Main charge duration dependent on battery type The Erhaltungsladen Trickle charge indicator lamp does not light up despite several hours of full charge No mains voltage Switch on the circuit breaker in the vehicle Have the mains voltage checked Contact the customer service department Check the fuse and wiring Battery charger is defective Battery charger fuse or wiring is defective Contact the customer service department Battery charger is defective Switch on the circuit breaker in the vehicle Have the mains voltage checked Contact the customer service department No mains voltage Battery charger is defective Defective fuse or wiring Battery charger is Contact the customer defective service department No mains voltage Switch on the circuit breaker in the vehicle Have the mains voltage checked Contact the customer service department Check the fuse and wiring Defective battery Contact the customer service department Defective battery Contact the customer service department If the battery is not defective Battery charger defective A The charging current is reduced automatically if the device becomes too hot due to excessive ambient temperature or lack of ventilation Always prevent the device from overheating nevertheless Date 06 11 2014 810 523 BA EN 810 523 BA EN 1 4 Cleaning Instruction Manual and Ins
22. tallation Instructions LAS 1218 2 Maintenance The battery charger is maintenance free Clean the battery charger with a soft slightly damp cloth and mild detergent Never use spirit thinners or similar substances Do not allow liquids to enter the device Date 06 11 2014 Instruction Manual and Installation Instructions LAS 1218 2 2 Installation instructions 2 4 Introduction These installation instructions are aimed at trained personnel They contain important information on the connection and safe operation of the device The safety information provided must be observed Always follow the relevant instruction manual in addition to the installation in structions The following applications are described for the electrical connection with the appropriate deliverables e Auxiliary charger on electroblock section 1 1 1 1 e Direct connection to living area and starter battery section 1 1 1 2 e Connection to additional battery e g when using in conjunction with an inverter section 1 1 1 3 2 2 Mechanical installation 2 2 1 LAS 1218 2 battery charger A This device is intended for installation into a vehicle The device was designed for floor installation Environment Install in a dry sufficiently ventilated location No condensation is allowed to form on the device To prevent a build up of heat ventilation holes fa cing the living area must be provided in the upper and lower areas of the place of in
23. ving area battery must be connec ted externally to the negative terminal Pol of the starter battery Date 06 11 2014 13 Instruction Manual and Installation Instructions LAS 1218 2 1 1 1 3 Connection to additional battery such as when using in conjunction with inverter With this type of connection the LAS 1218 2 battery charger is used for loa ding an additional battery Deliverables The following parts are supplied under item number 999 086 for this applica tion Fig 6 Connector set deliverables Pos Qty Name 1 1 LAS 1218 2 battery charger 2 7 Flat push on contacts 6 3 x 0 8 blue 3 Ring terminal 1 2 5 mm M6 4 3 Ring terminal 1 2 5 mm M8 5 2 Fuse holder for flat vehicle fuse 6 1 Flat vehicle fuse 20A 7 T Flat vehicle fuse 10 A Pos 3 and 4 each only required 2 x Pos 5 only 1 x Pos 7 not used The connector set Pos 2 to 6 is required to connect the LAS 1218 2 bat tery charger to the additional battery The application shown in Fig 7 is based on articles Connector sets for integra tion of an inverter article nos 798 023 and 999 208 available from Schaudt In principle such a connection is always suitable when an addition battery is char ged A The length of the line to the additional battery may not exceed 4 m sup e ply and return lines together for a cable cross section of 2 5mm see also table on page 9 terminal of LAS 12
Download Pdf Manuals
Related Search
Related Contents
NATULAN patients V1_5BPLJYTFM ATEX-Stellantriebe Manual de usuario báscula industrial serie K-Rekord Asrock 970 Pro3 R2.0 ANTICONGELANTE-REFRIGERANTE ACU 2300 CONCENTRADO BALANCE ELECTRONIQUE WB-100MA/WB-110MA CDS-021-01 Wireless EStop User Manual Samsung B1215J Felhasználói kézikönyv Copyright © All rights reserved.
Failed to retrieve file