Home
INSTALLATION AND USE MANUAL Narcotic Gas - Gemini
Contents
1. cscccsssssssssssssetessssccesssssneeteeeeeee PAGE 06 INSTALLER MANUAL 10 0 INSTALLATION 10 1 FITTING OF DETECTOR 7 10 2 ELECTRICAL CONNECTIONS cccsssssssssssssssssssssettseeeeeed PAGE 07 10 3 MOUNTING DIAGRAM ox cxsscsisecesccesucsehcanscoscsonasinnsoscvesinoe 11 0 SELF LEARNING PROCEDURE 12 0 CIRCUIT DIAGRAM sssessssssseseesssesssecseeeeeeeee 13 0 CORRECT POSITION FOR LPG DETECTION 05 PAGE 09 14 0 TECHNICAL SPECIFICATIONS PAGE 10 15 0 WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT DIREC TIVE WEEE sccctsf sc avd overeatsdenteeeeiniosctvawectaeesdtiesaveesacvel PAGE 10 PAGE 02 1 0 INTRODUCTORY NOTE Dear Customer Thank you for purchasing a Gemini product The present manual has been written to help you understand and use the narcotic and LPG wireless detector 911W specifically designed for recreational vehicles Read the supplied instructions thoroughly and keep them handy USER MANUAL Should gas be sprayed into your vehicle the 911W sensor is able to detect it and set off an alarm in a few seconds long before the gas can have any effect onthe occupants The loud siren will also discourage anyone trying to break in your motorhome N B In compliance with European standard En50194 the detector can signal the presence of explosive gas LP when its concentration is higher than 10 of the LEL Lower Explosive Limit the minimum concentration which can cause an e
2. I level for explosive gas LPG 10 of the LEL 7 0 IMPORTANT CAUTIONS e Use only a damp cloth to clean the detector do not use thinners alcohol detergents etc which could irreparably damage the detector e Alcohol based cleaning agents perfumes deodorants varnish thinner fumes insecticides and other sprays can interfere with the correct operation of the sensor and create improper alarms and or alter the device sensitivity e Silicone vapors in the cabin can deteriorate the detector sensing element Changing the sensitivity setting will not modify the alarm threshold USER MANUAL PAGE 05 8 0 SIGNAL SYMBOLS SYMBOL COLOR DESCRIPTION Yellow Signaling of specific functional conditions see table 8 1 8 1 YELLOW LED SIGNAL INDICATIONS YELLOW ACOUSTIC DETECTOR LED ALERT CONDITION Consecutive flashings Starting and warming up On stead Short beep Out of order due to exhaustion of neteady every 5 minutes probe after 11 000 working hrs 9 0 WARRANTY CONDITIONS This product is guaranteed to be free from defects in workmanship for a period of 24 months from the date of installation reported on the present warranty in compliance with the1999 44 CE Warranty Directive L D N 24 02 02 2002 Please fill in entirely the guarantee certificate included in this manual and DO NOT REMOVE the guarantee label affixed to the device The warranty will become void if labels are missing or torn if the installati
3. chap 12 the supply terminal block must be depressed to introduce the cables which must have a section comprised between 0 5 and 1 5 mm 10 3 MOUNTING DIAGRAM per kej FF Pre drilled mounting holes use the lV ones to the far ends f FC Pre drilled holes to run the cables FR 2 __ gt FC use the ones on the left for the power aan cable fae ch FR Power supply cable holder Er FF a Figure 1 l FeO INSTALLER MANUAL PAGE 07 11 0 SELF LEARNING PROCEDURE Before starting the learning procedure of the sensor identification code activate the learning procedure requested by the GEMINI alarm system refer to the alarm instruction manual Once activated proceed as follows e Use an unlit butane lighter to spray a small quantity of gas near the FIGARO sensor located on the PCB base near the three LEDs e Make sure that when the alarm signals are triggered the red LED DL 2 turns ON and the buzzer sounds the transmitter transmits for about 2 sec the red LED on the transmitter circuit must turn ON e The audio visual alarm signals will cease as soon as the air clears or when the power is cut off e By triggering the alarm condition the detector transmits a radio code that will be learned by the GEMINI alarm system indicated by the appropriate signaling e Once the sensor is registered complete the learning procedure as indicated in the GEMINI al
4. INSTALLATION CERTIFICATE The undersigned qualified installer attests to have personally fitted the here described detector on the following vehicle according to the manufacturer s instructions By Sold on Type of device O 911w Vehicle GEMINI Technologies S p A Via Luigi Galvani 12 21020 Bodio Lomnago VA Italia Tel 39 0332 943211 Fax 39 0332 948080 www gemini alarm com GEM ALARM SYSTEMS Narcotic Gas and Explosive Gas Wireless Detector 911W INSTALLATION AND USE MANUAL T m Canroncan Reg n 532 A AC 2783UK Rev 00 12 09 For all EU Countries Uk CONTENTS 1 0 INTRODUCTORY NOT Bo viesvesceest scvncazesteveenivesttice centered tese PAGE 03 USER MANUAL 2 0 OPERATION DESCRIPTION evcccseiscessercevseezerecensevecectasevsaveresd PAGE 03 2 1 STARTING AND WARMING UP c ccccesscccesseeeessseeeeees PAGE 03 3 0 ALARMISIGNAES ise ccsticcesccezdsscveconevceevesscesicsiahaceta Apia Erani PAGE 03 3 1 NARCOTIC GAS vic ecsrecavstrtrenrannieaccaawcanasiend PAGE 04 3 2 LPG EXPLOSIVE GAS o cccssssssssssssssssssccsssssssssseesscceessssssnees PAGE 04 4 0 POWER SUPPLY 0 000 5 0 SELF DIAGNOSIS ccssssseeeeeee 6 0 SENSITIVITY LEVEL SELECTION 7 0 IMPORTANT CAUTIONS 8 0 SYMBOL INDICATIONS csssssssssssssssessescessssssssstesseeeseenssssee PAGE 06 8 1 YELLOW LED SIGNAL INDICATIONS E 9 0 WARRANTY CONDITIONS
5. It should be deposited at an appropriate facility to enable recovery and recycling Directives 2002 95 CE 2002 96 CE and 2003 108 CE For information on how to recycle this product in your country visit www eur lex europa eu APPROPRIATE CONTAINERS ONLY PAGE 10 INSTALLER MANUAL
6. arm instruction manual NOTE the installer sprays gas from a lighter to activate the learning procedure of the radio code but also to make sure that the unit is fully operational a Repeated use of a butane lighter to spray gas can alter the I detection sensitivity l NOTE instead of butane lighters engine starting aid sprays can be used by the installer for testing and learning the detector PAGE 08 INSTALLER MANUAL 12 0 CIRCUIT DIAGRAM 12V SL1 24V oo C n za Q 12 24V Card fixing __ E na Screw M2 Push button type terminal block for 12V or 24V S11 Voltage switch 12 or 24V P1 Sensitivity level selector 13 0 CORRECT POSITION FOR LPG DETECTION The detector must be installed at about 20 40cm from the floor as illustrated here below i Min 1 meter E Max 5 meter INSTALLER MANUAL PAGE 09 14 0 TECHNICAL SPECIFICATIONS Power supply selectable via the 12Vcc 10 to 14Vcc SL1 switch 24Vcc 20 to 28Vcc Maximum absorption 100mA f Alarm sound pressure level 90dB at 30 cm Working temperature Da 5 C a 45 C Dimensions O f Ctx 68x 35 mm Plastic casing PC Polycarbonate and inflammability class V2 GW 750 15 0 WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT DIRECTIVE WEEE In the European Union this label indicates that this product must not be disposed of with household waste
7. l in the cabin if its concentration exceeds 10 of the L E L Lower Explosive Limit the detector immediately activates the built in radio transmitter which actuates the siren of the Gemini alarm system 863MH tracker etc The alarm state stays on until the conditions which have generated it are present Important Note for LPG detection the sensor must be installed according to the installation instructions see chap 13 0 4 0 POWER SUPPLY The detector can operate both at 12V or 24V by setting the voltage switch S11 To select 24V turn the detector off open the casing by pressing both sides lightly to access the electronic card and set the SL1 switch to the desired voltage PAGE 04 USER MANUAL 5 0 SELF DIAGNOSIS The detector is provided with an acurate and reliable self diagnosis system which continuously checks its performance and efficiency any failure or the exhaustion of the probe after a life cycle of more than 11 00Ohrs is signaled by the yellow LED turning ON and by awarning alert signal r When the probe is exhausted contact an authorized dealer for l I replacement or reconditionning of the detector l 6 0 SENSITIVITY LEVEL SELECTION By default the detector is set to normal sensitivity in case of particular environmental conditions the sensitivity can be set to low by opening or interrupting jumper P1 Jumper P1 closed normal sensitivity Jumper P1 opened low sensitivity
8. on certificate is not fully compiled or if the enclosed sale documentis missing The warranty is valid exclusively at authorized Gemini Technologies centers The manufacturer declines any responsability for eventual malfunctions of the detector or any damage to the vehicle electrical system due to improper installation use or tampering PAGE 06 USER MANUAL INSTALLER MANUAL 10 0 INSTALLATION The wireless detector 911W is intended for a permanent installation The device must be positioned at about 20 40 cm from the vehicle cabin floor to be protected The detector must be installed at least 1 1 5m away from any air supply register if there is an air intake vent install the detector near it 10 1 FISSAGGIO DEL RIVELATORE e Remove the detector cover by prying lightly with a screwdriver inserted in the release slot on the right side of the casing e The two screw holes FF can be used to mount the detector to a wall or onto a base fig 1 the electronic card must first be removed by unscrewing the screw on the bottom right corner see par 12 10 2 ELECTRICAL CONNECTIONS e The pre drilled holes FC areused to run the power wiring see par 10 3 e Connect the wires that supply 12 or 24V to the terminal block M2 see par 12 depress the supply terminal block to introduce the cables which must have a section comprised between 0 5 and 1 5 mm e Connect the wires that supply 12 or 24V to the terminal block M2 see
9. xplosion 2 0 OPERATION DESCRIPTION We recommend operating the detector only when the vehicle is parked at bedtime If the detector is switched on uselessly ex While driving when the vehicle is stowed away etc the detecting probe may exhaust 2 1 STARTING AND WARMING UP When power is applied to the detector it will go through a warm up period and will be inhibited for at least 3 minutes during this so called warm up phase the yellow LED will blink This phase is necessary to allow the sensible element to warm up and stabilize itself in order to ensure proper operation conditions After this time delay the yellow LED turns off and the detector is ready to work USER MANUAL PAGE 03 3 0 ALARM SIGNALS 3 1 NARCOTIC GAS The detector continuously monitors the narcotic gas concentration level in the cabin by carrying out calculations to self adapt to the different air quality conditions use in urban areas is different from use in country places If a sudden increase in the concentration level is detected due to narcotic gases being sprayed in the vehicle the detector immediately activates the built in radio transmitter which actuates the siren of the Gemini alarm system 863MH tracker etc The alarm state remains ON until the conditions which have triggered it are present To deactivate the alarm simply disconnect it 3 2 EXPLOSIVE GAS LPG The detector continously monitors the LPG concentration leve
Download Pdf Manuals
Related Search
Related Contents
Memento Enseignants - Brevet du Cycliste 品 名 カタログ製品名 〝) 備 考 救命胴衣灯 日本船燈 (株) 「LFー3 5型」 数 Pinnacle Speakers SoundBridge Wireless Network Music Player User's Manual NG-NetMS Rel 3.4 User Install documentation 1. Before initial operation of the receiver Magnavox MVR430MG VCR User Manual Copyright © All rights reserved.