Home
        INSTALLATION · MANUAL 5.0670.11.24 1/2
         Contents
1. EN Wire colour        LED out 3      LED 3     blau blue bleu       LED out 3      LED 3     wei   white blanc       LED out 2      LED 2     gr  n green vert  LED 2     gelb yellow jaune       LED out 2    LED out 1      LED 1     rot red rouge       LED 1     schwarz black noir       LED out 1         AAAA       NTC Temp     NTC  temp     grau grey gris          NULL  Zero cero  PHASE 230V  ERDE  Ground terre          NTC  temp     braun brown marron                                     w Sicherung Fuse 2A  Mittel Tr  ge    5  Anschlu  belegung mit POW LED 27 x 3 5 W Modul  Wiring Diagram with POW LED 27 x 3 5 W modul   Raccordement avec POW LED 27 x 3 5 W module   5 0670 11 24    Aderfarbe Wire colour couleur de c  ble       blau blue bleu         blau blue bleu         gr  n green vert         gr  n green vert         gelb yellow jaune  ge  EE    max 1                   rot red rouge        rot red rouge  rt                 rot red rouge   schwarz black noir  sw              max 30 m             6  Wichtige Hinweise    Bei Nichtbeachtung folgender Punkte    entf  llt die Garantie     e Vor der Installation m  ssen alle Teile auf Transportsch  den    berpr  ft werden    Jegliche Montage   Installations  und Elektroarbeiten m  ssen von  qualifiziertem Fachpersonal durchgef  hrt werden    e Zur Vermeidung von Fremdrost nur Edelstahlwerkzeug verwenden    e Die Kabell  nge der Leuchten ist so zu w  hlen  dass man nicht im  Wasser oder feuchten Umgebung verl  ngern muss  Sp  ter
2. INSTALLATION   MANUAL       5 0670 11 24    700 mA Netzteil IP65  monochrom  700 mA Power Supply IP65  monochrom  700 mA alimentation IP65  monochrome       Si    WIBRE          e    5 0670 11 24    1  Description  700 mA RGB power supply for 27 POW LED 3 W modul  monochrom  27 POW LED 3 W Modul  monochrom for serie WIBRE 4 0271 4 0272 4 0273 4 0275  f  r Serie WIBRE 4 0271 4 0272 4 0273 4 0275   Softstart    Softstart   IP65 plastic housing    IP65 Kunststoffgeh  use   Temperature control input    Temperatur  berwachungseingang   max  distance between power supply and    max  Leitungsl  nge zwischen Netzteil und POW LED light  lt  30 m  POW LED Strahler  lt  30 m    1  Beschreibung  700 mA Netzteil zum Anschluss von    2  Spezifikation 2  Specification          Abmessung  254x 180 x 90 mm Dimension  254x 180 x 90 mm  Gewicht  2 5kg Weight  2 5kg  Eingangsspannung  230V AC    10   nput  230V AC    10   Eingansfrequenz  50   60 Hz Frequency  50   60 Hz  Wirkungsgrad  82  Efficiency  82   Ausgangsspannung  12 V DC  bei ALL ON  Output Power  12 V DC  on ALL ON   Ausgangsstrom  2 1 A je Kanal Output Current  2 1 A per channel  Temperatur  berwachung  10 k Ohm emperature control NTC  10k Ohm  Betriebstemperaturbereich   10  C      45  C Operating temperature   10  C      45  C  Lagertemperaturbereich   20  C      70  C Storage temperature   20  C      70  C    3  Garantiebestimmungen 3  Warranty conditions             Folgende Garantiezeiten und Bestimmungen gelten The following w
3. arranty times and conditions are valid from   vom Tage der Lieferung an  the day of delivery      24 Monate auf WIBRE Produkte   24 months on WIBRE Products     Unter die Garantie fallen nachweisbare Material   Konstruktions    Proven faults appertaining to material  construction or processing fall  und Verarbeitungsfehler von seiten des Herstellers  under the warranty of the manufacturer      F  r Sch  den  welche durch Nichtbeachtung dieser Betriebsan  We accept no liability for damages arising through negligence of the  leitung  oder durch unsachgem    e Reparatur entstehen  k  nnen operating instructions or improper repair work   wir keine Garantie   bernehmen    No liability is accepted for installation carried out contrary to the     Sch  den durch falsche Handhabung sind von der Garantie ausgeschlossen  instructions or for the use of inappropriate light bulbs      Keine Garantie besteht wenn die Installation nicht korrekt nach den  We reserve the right to instigate any technical improvements without  Bestimmungen vorgenommen wurde  oder bei Verwendung nicht prior notice     geeigneter Leuchtmittel  Use the light only under water       nderungen  die dem technischen Fortschritt dienen  behalten  wir uns vor     Betrieb des Scheinwerfers nur unter Wasser     WIBRE Elektroger  te Edmund Breuninger GmbH  amp  Co  kp  Liebigstrasse 9   74211 Leingarten Germany  Telefon   49  0  7131 9053 0   Telefax   49  0  7131 9053 19   E Mail  info wibre de    1  Description  700 mA ali
4. e Rekla   mationen aufgrund dessen k  nnen nicht akzeptiert werden    e Es d  rfen nur originale Wibre Betriebsger  te verwendet werden    e Ein Montageabstand von 10 cm zwischen Betriebsger  ten wird  dringend empfohlen  um wechselseitiges Erhitzen zu vermeiden    Anschluss der Betriebsger  te muss stromlos erfolgen  da sonst  Entladungen im Netzteil zur Sch  digung der LED f  hren k  nnen   Es darf keine Prim  rspannung beim Wechsel der LED anliegen    e Beim Anschlie  en der Leuchte die Polung beachten  Eine falsche  Polung kann dem LED Modul schaden      Die Installation eines bauseitigen   berspannungsschutzes nach  DIN VDE 0100 443  DIN VDE 0100 534 und EN 62305 wird  empfohlen    e Bitte achten Sie auf Ma  nahmen gegen ESD  Elektrostatische  Entladung  w  hrend aller Arbeiten am Scheinwerfer  Betriebsger  t  und LED     2    6  Important information    If the following points are disregarded    the guarantee expires       Before installation  all parts must be checked for transport damage    e All fitting  installation and electrical work must be performed by  qualified specialist staff    e Only use stainless steel tools to avoid external rust      The cable length of the lights should be chosen in such a way that  it is not necessary to extend in water or moist environments  Later  complaints resulting from this cannot be accepted    e Only original Wibre operating units may be used    An installation distance of 10 cm between operating devices is  urgently recommend
5. ed in order to avoid mutual heating up      The operating devices must be connected without power  as  otherwise discharges in the power supply may cause the LED to  be damaged  No primary voltage may be applied when changing  the LED    e Note polarity when changing the lights  The wrong polarity can  damage the LED module    e It is recommended that the customer install an overvoltage pro   tection in accordance with DIN VDE 0100 443  DIN VDE 0100 534  and EN 62305    Please comply with all anti ESD  electrostatic discharge  measures  during all work on the spotlight  operating device and LED     6  Remarques importantes    La garantie s    teint en cas de non respect   des points suivants    e L absence d avaries de transport doit   tre v  rifi  e avant  l installation     e Tous les travaux de montage et d installation  ainsi que les travaux    lectriques  doivent   tre r  alis  s par du personnel qualifi      e Afin d   viter tout d  p  t de rouille  utiliser exclusivement des outils  en acier inoxydable     e La longueur de c  ble des lampes doit   tre choisie de telle sorte    ce  qu il ne soit pas n  cessaire de la prolonger dans de l eau ou dans un  environnement humide  Toute r  clamation ult  rieure    ce motif ne  sera pas accept  e    e Seuls des   quipements Wibre originaux doivent   tre utilis  s    e Une distance de montage de 10 cm entre les   quipements est  vivement recommand  e afin d   viter un r  chauffement mutuel    e Le raccordement des   quipements d
6. mentation pour 27 POW LED 3 W module  monochrome  pour s  rie WIBRE 4 0271 4 0272 4 0273 4 0275    Softstart    IP65 bo  tier en ABS    Control de la temp  rature    distance max  entre alimentation et  dernier projecteur 30 m  tres    2  Sp  cification    Dimensions  254x 180x 90 mm  Poids  25kg   Tension primaire  230 V AC    10   Fr  quence primaire  50   60 Hz   Efficience  82    Tension secondaire  12 VDC  on ALL ON   Courant secondaire  2 1 A par sortie  Control de la temp  rature  10k Ohm   Temp  rature de r  gime   10       45  C  Temp  rature du stockage   20       70  C       3  Dispositions de garantie   Des p  riodes de garantie et dispositions suivantes sont   en vigueur au jour de la livraison      24 mois pour les produits Wibre     la garantie couvre des erreurs de construction d  montrables   de mat  riel et de traitement de la part du fabricant     pour des dommages qui r  sultent de non respect de ce manuel ou de  r  paration inad  quate  nous ne pouvons pas assurer la garantie     des dommages par une fausse manipulation sont exclus de la garantie     aucune garantie n existe si l installation n a pas   t   entreprise correctement  apr  s les dispositions  ou lors d une utilisation de sources non appropri  s      nous nous r  servons le droit de faire des modifications qui r  sultent de  l   volution technique de nos produits   Utilisation le projecteur seulement dans l eau     4  Anschlu  belegung   Wiring Diagram   Raccordement   5 0670 11 24    ADERFARB
7. oit   tre effectu   sans courant   sans quoi des d  charges dans le bloc d alimentation pourraient  entra  ner une d  t  rioration des LED  Aucune tension primaire ne  doit   tre   tablie lors du changement des LED    e Lors du raccordement des lampes  respecter la polarit     Une erreur  de polarit   peut endommager le module de LED    e L installation d une protection contre la surtension par le client  conforme aux normes DIN VDE 0100 443  DIN VDE 0100 534 et  EN 62305 est recommand  e    e Veuillez respecter les mesures contre la d  charge   lectrostatique  durant tous les travaux sur des projecteurs    quipements et LED     WIBRE Elektroger  te Edmund Breuninger GmbH  amp  Co  KG   Liebigstrasse 9   74211 Leingarten Germany  Telefon   49  0  7131 9053 0   Telefax   49  0  7131 9053 19   E Mail  info wibre de    W224 Stand 06 15   Technische   nderungen vorbehalten   F  r Druckfehler   bernehmen wir keine Haftung    
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
AF 100 - Midland Power Distribution Limited    PORTUGUÊS - Temar srl  Lincoln 2010 MKT User's Manual  Manuel d`utilisation et carnet d`entretien Micro  Tristar KO-6384DU hob  Operating instructions Compact balance  Techniker – Schulung  ATTIX 3-5-7_302001673 C ny.indb  ScanMate    Copyright © All rights reserved. 
   Failed to retrieve file