Home

Installation & Maintenance Manual

image

Contents

1. Monolithic modules may produce dangerous current or voltage being exposed to direct sunlight 5 System designers and installers have to use a stable and prior calculated bracket to make sure the modules will be fixed safely to the roof Fix the modules to the bracket according to the recommendation of the engineer or supplier Please refer the 9th point of this Installation manual 6 The installation debugging and maintenance of the modules must be performed by following all electronic safety regulations for photovoltaic devices f In standard test conditions the standard test condition is irradiance of 1000 W m2 battery tag temperature of 25 C and a spectrum of AM1 5 the electrical performance parameters of the Modules such as Isc Voc and Pmax may have a 10 deviation with the nominal value 8 Do not step or lean on the modules 9 Do not spray any chemicals or paints on the modules 10 When exchanging any module or in case of maintenance please take all necessary precautions to avoid electrical injuries A A elite solar GmbH Wilhelm Beckmann Str 6 D 45307 Essen Germany Email info elite solar de Internet www elite solar de ler oye PVY CYCLE LISTED 4 Installation amp Maintenance Manual EliteSolar Performer Series Transportation 1 Always remember that pv modules are fragile goods Please handle them with care 2 Keep the modules away from inflammable gas hazardous chemicals or fire sourc
2. ant 7 The electric installation must be designed by a registered professional engineer and installation procedures and designs must be in compliance with your countries laws for electronic installations elite solar GmbH Wilhelm Beckmann Str 6 D 45307 Essen Germany Email info elite solar de Internet www elite solar de ak 5 m ve PV CYCLE bi alita cniar T l ele ee LA We develop the future Installation amp Maintenance Manual EliteSolar Performer Series 8 You may choose one of the fixing methods shown in the picture below Screw fixing system Drawing 1 a Fixture fixing system Drawing 1 b or Inserting System M8 screw bolt module aluminum frame the mounting structure M8 screw nut M flat gasket M8 flat gasket M8 spring cushic MS screw bolt module aluminum frame M amp S flat gasket pe M8 flat gasket ih _____ the mounting structure M amp spring cushic Drawing 1 b Installed by fixture lt MS screw nut Drawing 1 a Installed by nut and bolt Drawing 1 a Installed by nut and bolt Drawing 1 b Installed by fixture Note The percentage of the safety factor for voltage current etc is depending on the geographical conditions the modules are installed in and may vary from country to country 9 Installation method and location bi For other series module fix the module with the long side Drawing d a Aa Screw fsing fix the modules on the bracet on the bracket at border oreta
3. briceted arsharl side Drawin 4 6 according to the brackel designator Installation holes Drawing and mechanical load requirement L t Sromdard Installing hale i iretalling hole fer sireng wind and heavy amra Ligseshfd azcn 2400 Fa Drawing 4 2 Haing an the long Hdr Series Drawing 2 Screw fising Bi Fixture fixing Fix the module sately and ettectively on the brackets with spec al installation tools aj A Series 156 72 medules Six clamps must oo usedi Drowing 3 Ligseshid aeiem D400 Pa Dring 4 a tying om the jong de for the other module series Liseli azem Drawing a gn lang frame WASEDA E ankem 240 Pa Drawing 4 b fixing on the king side for the other module series wyEtesia aBecm Drawing 3 b on shart frame Anyway Tx elght instellation holes simultaneously is recommended according ta the Security Considerations In the correct installation method the Modules could biggest bear snow pressure of 5400pa or wind pressure of 2400pa_ elite solar GmbH Wilhelm Beckmann Str 6 D 45307 Essen Germany Email info elite solar de Internet www elite solar de ce U1 US Gus C Oo as MCS LISTED Intertek aiita solar wli We ai hh ania Installation amp Maintenance Manual EliteSolar Performer Series 10 When installing the modules on the roof ensure there is an appropriate structure which has the same or higher maximum load than the modules themself Make sur
4. e there is no water leaking between the mounting brackets and roof construction 11 Installing the modules on the roof may affect the fire risk rating of the house It may be necessary to recalculate the rist class insurance etc 12 The grounding method shall be corresponding with the local standards and regulations The grounding wire shall be the bare copper wire with simple surface treatment and no insulation Wire thicknesses of 10 12 AWG or higher may be used Ground clamp Tyco identification of product 1954381 2 is recommended 13 When the connecting wire of the modules clita can not meet the system design requirements 2 Jet 4 5 a proper commercial cable for long term a fer pe S ea i outdoor use and suitable connector shall a i 5 a C4 i P a w be used to extend the connecting wire I rs s The extended wire shall be no less than 4mm and the connection system shall meet IP65 rating 14 The minimum space between two Modules shall be more than 10mm when installed on the roof the minimum separation between the Modules and the mounting surface shall be more than 150mm and when installing on the ground more than 450mm 15 It is recommended to only use modules of the same electrical parameters in one system Maximum number of series N Vmax System Voc under the lowest temperature in local environment and meets the voltage range of the MPPT of the inverter 16 Artificially concentrated sunlight may not be directed t
5. es 3 Do not carry wet modules Especially the glas surface Is very slipperly when wet 4 We strongly recommend to ship pv modules in suitable containers fill free spaces with inflatable bags In case the modules cannot be shipped in a container we recommend to single pack all modules and make sure they are well protected from outside impacts 5 The surface oxide layer of the border may be scratched by sharp objects do not destroy or scratch the border of the modules Installation 1 Installers must be qualified engineers Do not try to install PV modules without an electronical profession 2 Do not use damaged modules Damaged modules may cause fire or electric shock both may result in serious injury or death 3 Do not disconnect any wires while the py modules are producting electricity 4 Under normal conditions a photovoltaic module may produce voltages and currents higher than in standard test conditions All connected electronic devices shall be able to work with 1 25 times higher current and voltage 5 The Modules shall be installed in the position of highest sun irradiation to avoid low efficiency of the system to be installed In the northern hemisphere the modules shall be installed facing the south and vice versa 6 Use a mounting bracket with a simular or higher maximum load to ensure a safe construction at heavy snowfall or strong winds Make sure you choose a durable and safe bracket which is corrosion and UV resist
6. n the table above are representing the module power in Wp 5 For detailed information please check our module description sheet 2 ES represents elite solar while M is used for mono christalline cells and P for poly christalline or amorphe christalline cells 3 The information in the table above also shows the cell backsheet color Black cells will always have a reduced power of about 5Wp at the same cell amount and design as a result of the existing power loss All module Wp statements are real Wp and will not be reduced for any further aspects Y CE l An a E Tanga Ki m Intertek elite solar GmbH Wilhelm Beckmann str 6 D 45307 Essen Germany Email info elite solar de Internet www elite solar de Installation amp Maintenance Manual EliteSolar Performer Series General use 1 The installation and maintenance of photovoltaic modules Is always a potential risk because of dangerous voltages Please make sure to work after all safety relevand electric installation rules and guidelines and make sure only proffessionals are installing the photovoltaic system 2 Do not unmount the modules or parts of them and do not tear off any labels 3 Do not touch the exposed cables or connectors There is a high risk of flash shocks even without any other devices than the pv modules installed 4 After unpacking the modules make sure they are completely covered from the sunlight to avoid the risk of an electric shock
7. o c PAPI enlar W Ge h F ee Ed We develop the future Installation amp Maintenance Manual EliteSolar Performer Series Content Preface 01 Module types 02 General use 03 Transportation 04 Installation 05 Product identification 11 Maintenance 11 Annual inspection 11 Disclaimer of Liability 12 Applicable Law and Dispute Settlement 12 Preface This manual offers general installation and maintenance information of elite solar Performer photovoltaic modules hereinafter called the Modules of elite solar GmbH hereinafter called elitesolar Before installing our modules or any maintenance procedures make sure you carefully read and understood all information in this manual and all general professional installation procedures of photovoltaic systems lf you have any questions please feel free to contact our customer support at any time during your installation elite solar GmbH Wilhelm Beckmann Str 6 D 45307 Essen Germany Email info elite solar de Internet www elite solar de Gus r ran AZ Installation amp Maintenance Manual EliteSolar Performer Series Module types ESP660250 white ESP660260 white ESP6 72300 white ESP672310 white ESM572190 white ESM572200 white ESM660250 white ESM660260 white ESM660275 white ESP660250 black ESP660260 black ESP672300 black ESP672310 black ESM572190 black ESM572200 black ESM660250 black ESM660260 black ESM660275 black 1 The last 3 digits i
8. o the modules 17 Our modules have passed the salt mist and ammonia test Please refer the test report for detailed information and may e installed even in more critical environment e g at the sea side Please do not remove any label A non labeled module will void warranty and may not be exchanged in case of damages For annual inspection 1 Check if nuts and bolts of the mounting structure are securely tightened and not loose Tighten the loose components If necessary 2 Check the water resistance of the connectors cables and ground cables as well as the ground resistance 3 Check all electrical and mechanical connections for its proper location and corrosion 4 Check the ground resistance of all metal parts such as the module frames and the mounting structures elite solar GmbH m Wilhelm Beckmann str 6 Ell Wo D 45307 Essen Germany SE PV CYCLE Email info elite solar de MIPE bl Internet www elite solar de i rm r E ed