Home

Installation manual xxter v1 9 1

image

Contents

1. From September the 30th till October the 4th the 2 annual fair Elektrotechniek will take place in the Jaarbeurs In Register a new device This registration wizard will help you to register your xxter The Android app has been updated to version 1 9 0 New in this update This is an important part of setting up and configuring your xxter which will link your device to your Web component to display a web personal account This account is needed to configure your xxter URL in side During this wizard you can always start over by pressing the cancel button Serial number Download our new product sheet for more information on xxter Next Firmware update 1 9 1 is now available Within this update some small bug fixes The firmware can be updated through the web interface Image 3 Registration help Please remember the usernames and passwords well because they are needed for the rest of the installation The end user information can be written down on the back page of the user manual The serial number of the device can be found on the back page of the user manual on the device itself and on the packaging 10 xxter installation manual 6 Configuring KNX components For the configuration of a KNX installation in xxter the KNX group addresses will have to be transferred to xxter as components in the project The easiest way to do this is by exporting the KNX configuration in ETS as an OPC extr
2. XX CCL Installation manual Version 1 9 1 January 2014 2014 xxter bv All rights reserved Screenshots in this manual and the actual screens on your computer can be different Updates are made to the website and the products on a regular basis More information can be found at www xxter com 2 xxter installation manual Contents Oe Soe eS eS Introduction xxter configuration overview Project configuration xxter basic installation Registration Configuring KNX components Configuring Artnet components Connecting the device Set up Teaching in enOcean components Setting up Hue components Initialization Using xxter over the Internet Updating firmware Reset options and status LEDs Programming KNX through xxter Service and support Addendum A component types xxter installation manual NO U1 10 12 13 15 17 18 19 19 20 21 22 23 23 Welcome With xxter you can extend your automated home or office in only a few steps and control it with a smartphone or tablet This manual is intended for the installation professional and starts with a short explanation of the working and configuration options of xxter In the following chapters you will be taken through the steps for initial registration configuration connecting the device and initialisation The explanation of how the visualisation for smartphones and tablets can be created and adapted is included in the user manual
3. specified group by for example a KNX switch xxter will execute the specified scenario xxter installation manual 11 7 Configuring Artnet components To configure Artnet DMX equipment for instance to control RGB led lighting the Artnet DMX identification of the specific components must be transferred to the project Every DMX address will usually have to be included as the sending group as well as the status group Arnet DMX only supports byte values and can be used with switches dimmers sending byte values and RGB led lighting When a switch is used in combination with a DMX address that address will be set to 100 when an on command is given A DMX address consists of a universe and an address The universe can be between 0 and 31 and the address between 0 and 511 In the xxter configuration DMX addresses always contain the prefix DMX followed by the universe a and then the address An example of a DMX address is DMX 0 12 With which we intend address 12 of universe 0 12 xxter installation manual 8 Connecting the device The steps to connect the xxter device depends on the model that is used For all models the UTP cable has to be connected to the internal network xxter has to be able to connect to the Internet to download the configuration and for future firmware updates KNX direct In case you are using a xxter model with a direct KNX bus connection HK01 of HKEO1 then connect the bus cab
4. for red green and blue Together they set one RGB lamp to the desired colour Bit Byte values can be used to send or receive values from the home automation installation The type of component defines what kind of bit or byte value should be used Sensor values like temperature wind speed etc can be used to read information from the home automation installation but can also be used to send a value for instance to set a thermostat temperature xxter installation manual 23 Technical specifications Size Ixwxh 180x152x38mm Weight 0 5 kg Voltage 5VDC Power consumption 300mA avg Cooling passive Accessories Adapter 5VDC UTP cable enOcean antenna only for models HE01 HCE01 en HKEO1 Installation manual EN User manual EN The other specifications can be found on the back page of the user manual 24 xxter installation manual
5. possible to grant access through the configuration menu on the settings page with the option Allow access to KNX bus This way the end user can grant you as the installation professional temporary access for maintenance The app will enable access for a default period of 8 hours In case you want to have access to the xxter device for programming from a remote location your office you will need to extend access to xxter over the internet see chapter 13 with port forwarding for UDP on port 3671 With ETS you can then connect to the dynamic DNS address of the xxter device You can find this address as IP or host external on the devices page of My xxter 22 xxter installation manual 17 Service and support Answers to frequently asked questions can be found on http www xxter com faq Additional support can be found on http www xxter com support In case you are unable to resolve the issue here you can contact us on support xxter com Please always include the serial number of the xxter device it concerns Addendum A component types In this addendum we supply a short explanation for the project configuration of the most used types of components for home automation A switch refers to a relay or switch actor and can only be turned on or off A dimmer refers to a dimming actor and can be set to a scale of 0 to 100 RGB lighting is a combination of three connected dimmer components
6. 3 No Bridge BZ Switch gt Living room standing light 8 4 5 8 4 5 No Bridge CA Switch Living room TV aaja 8 4 4 No Bridge Image 2 project configuration example on My xxter Scenarios With the use of scenarios the end user can easily select a set of actions to perform with a single push on a button To support scenarios the installation professional must initially create the scenario groups to which xxter will react xxter will listen to the specified group address and value When a KNX or enOcean switch sends a telegram to one of these addresses xxter will perform that scenario Also scenarios can be used from within the visualisation It is recommended to create a reasonable set of scenarios even when they are not yet used by switches from the automated home The end user can always change the name of a scenario when using it in the visualisation How to configure and use scenarios is explained in the user manual 8 xxter installation manual 4 xxter basic installation Now the basic concepts of xxter are explained we can start with the installation The basic installation of xxter consists of the following steps 1 Registration chapter 5 2 Configuring home automation components a KNX chapter 6 b Artnet DMX RGB led chapter 7 3 Connecting the device chapter 8 4 Set up chapter 9 5 Teaching in home automation components a enOcean chapter10 b Phillips Hue chapter 11 6 In
7. 9 BUT1 Hold during boot Reset to factory defaults BUT1 Press shortly Full restart BUT1 Press long longer then 3 sec Reset to factory defaults BUT2 Press shortly Reset application soft restart When the xxter device is connected to power the system status can be seen using the LED indicators LED1 green slow flashing Currently booting or shutting down LED1 green continuous Application started and ready for use LED2 green slow flashing Normal operation OK LED2 yellow slow flashing No connection to KNX or enOcean LED2 red quick flashing LAN problem no network LED2 red green intermittent No Internet connection only LAN connection the Internet connection is only verified during boot and when the Check Internet connection button is pressed on the status page of the xxter device Image 9 xxter rear panel xxter installation manual 21 16 Programming KNX through xxter In case you are using an xxter device that supports KNX direct HK01 HKE01 it is possible to program with ETS through the IP address of the xxter device using the KNXnet IP tunnel protocol This access is normally disabled and must be activated by the user explicitly Access can be granted for a period of 1 hour 4 hours 8 hours or indefinitely After the device is connected and set up this option can be found on the status page of the xxter device under KNX tunnel input When the xxter app is installed and set up see user manual it is also
8. This makes it possible for the end user to fine tune xxter completely to his or her personal needs The installation manual expects you the installation professional to have basic knowledge on Ethernet networks and the applied home automation standard KNX ETS enOcean Artnet DMX Hue We often refer to the end user The end user is the intended person to use xxter after installation More information on the use of xxter can be found in the user manual This manual only describes the basic installation of xxter For additional options and extensions like cameras intercom systems uPnP audio control graphs scripts and many other options separate manuals are available Please refer to www xxter com for more information 4 xxter installation manual 1 Introduction With xxter you can easily control an automated home or office with a smartphone or tablet at home or over the Internet when you are away Additionally xxter gives you the possibility to connect the different home automation standards to each other and integrate it in one environment D E Hue bridge ko r fans 8 xxter KNX direct KNX IP gateway Artnet DMX node Image 1 xxter overview The configuration of xxter is stored on xxter s central servers This configuration is then downloaded on the xxter unit itself and in the app In the following chapters this central configuration is explained in more detail xxter installation manual 5 2 x
9. action and then import it in the xxter configuration tool Within the tool you can then drag and drop the relevant components from the ETS configuration to the xxter configuration More information on the configuration tool can be found in the configuration tool manual on the website In case you are using an xxter that supports KNX direct HK01 HKE01 you can program ETS directly through the xxter device see chapter 16 a xxter config tool Sx File View Settings Help Ose e e 4 e Project settings Actions Cameras enOcean Home 4 0 Lights ground floor i Rea Living room light 1 No lo No 0 0 Kitchen 1 Scenario Living room scenario 1 EE oo 1 E No a paral 7 Byte special mode 17 0 1 7 0 1 711 ated No No 02 0 h spotss 3 Byte value special mode Comfort 47 0 eae eee pt No No No 0 2 1 h spotsd 6 Byte value special mode Frost protection 47 0 O G No No No 0 2 2 h spots w 5 Byte value special mode Night 47 0 ee No No No 0 2 3 h spots rs 4 Byte value special mode Standby 47 0 D No No No 0 2 4 h spots rw 0 3 Hallway 0 4 Frontroom 0 5 Outside 1 Lights ist floor 2 Control and logic 3 Central functions Image 4 xxter configuration tool example To configure scenarios you can manually choose one or multiple free group addresses These need to be 1 byte 0 255 group addresses with a value between 0 and 255 When a certain value is sent to the
10. dard both dip switches to OFF numbered side 2 Repeat only original telegrams level 1 set only dip switch 1 to ON 3 Repeat both original and one time repeated telegrams set both dip switches to ON Before a new repeater setting is active it is required to shortly disconnect the ANEO1 from the power source 14 xxter installation manual 9 Set up The following settings need to take place on the xxter unit itself Access the device on the local network with your web browser using the IP address the xxter device has received http IP adres Normally xxter will automatically receive an IP address through DHCP You can look up the IP address that was given out on the DHCP server or router after the xxter device has fully started You can also access the IP search function in the configuration tool to find the xxter device In case xxter could not reach a DHCP server it will use the following default settings IP address 192 168 0 150 Netmask 255 255 255 0 To connect to xxter your computer has to use a similar IP address for instance 192 168 0 10 To continue the set up follow the xxter configuration help Select language Language English Next Image 7 configuration help You can write down the definitive IP address of the xxter device on the back page of the user manual xxter installation manual 15 After the basic settings are completed the protocol specific settings need to be set On t
11. e explicitly added when configuring the xxter app on a smartphone or tablet xxter installation manual 19 14 Updating firmware Regularly new versions of the xxter firmware will be released These releases can add new features but can also contain bug fixes or improvements On the xxter website the latest version of the firmware is listed The xxter device itself can verify whether new firmware is available Access the device on the local network with your web browser using the IP address of the xxter device and log in Then open the Settings system page and in the Firmware section press the Check button to check for firmware updates In case a new version is available you will be prompted to update the firmware By selecting update firmware the device will download and install the new firmware This can take some time After the firmware is successfully updated the xxter device needs to be restarted This can be done by clicking Reboot to reboot the device Important never turn off the xxter device while it is updating the firmware After updating the firmware we always advise to reload the configuration see chapter 12 It can be required to update the firmware multiple times in a row before the xxter device is updated to the latest version 20 xxter installation manual 15 Reset options and status LEDs In case of any problems the xxter device can be reset in several different ways see also image
12. he xxter unit open the Settings basic page KNX direct Under the KNX settings the KNX protocol should be enabled with the connection method set to Direct Verify whether the KNX physical address is not used on the KNX bus by another component We advice you to reserve this address in KNX as adummy component to prevent the address to be used by another device in the future KNX connection over IP Under the KNX settings the KNX protocol should be enabled In case you are using the KNXnet tunnel protocol enter the IP address of the KNX IP module In case you are using the KNXnet routing protocol set this feature to on and verify the standard Multicast IP address enOcean Under the enOcean settings the enOcean protocol should be enabled Artnet DMX Under the ArtNet settings enter the IP address of the ArtNet receiver To guarantee the connection between Artnet DMX and xxter after network disconnections xxter can repeat the status of the DMX components in a specified interval Turn on this feature if desired Philips Hue Under the Hue settings enter the IP address of the Hue bridge After the settings are applied push the button on the Hue bridge itself and subsequently on the button Link to Hue bridge When you open the Status page you can verify whether the KNX enOcean and or Hue are connected correctly 16 xxter installation manual 10 Teaching in enOcean components To
13. itialisation chapter 12 The configuration of KNX and DMX components can be prepared beforehand for example from the office before the xxter unit is physically connected and set up To teach in enOcean and Hue components the specific home automation components as well as the xxter unit have to be installed In case you want to prepare this from the office a test setup has to be created similar to the desired setup at the intended user location After the basic installation has been performed the visualisation from the smartphone or tablet can be configured The instructions for the visualisation can be found in the user manual Apart from the basic installation xxter also supports cameras intercom systems uPnP for audio control graphs scripts and many other features Separate manuals are available for these features on the website xxter installation manual 9 5 Registration Every xxter product has to be registered before use After registration the installation professional can configure the xxter and the end user can personalize it Therefore it is required to register xxter for the professional as well as for the end user For the registration of xxter please follow the registration help on http www xxter com register HOME PRODUCT INFORMATION PROFESSIONALS SUPPORT CONTACT MY XXTER November 20th and 21st the annual fair Smart Homes will take place in Eindhoven the Netherlands We will have a limited
14. le to pin 2 KNX min black and pin 3 KNX plus red see image 5 First connect xxter to the KNX bus and then connect xxter s power adaptor to the power socket Image 5 xxter rear panel KNX connection over IP When using KNX over a KNXnet IP module please make sure the xxter unit and the KNXnet IP module are both connected to the same internal network Artnet DMX For the use of DMX components an ArtNet gt DMX node is required This node must also be connected to the same internal network as the xxter unit A list of ArtNet gt DMX nodes that are tested with xxter can be found on the website Philips Hue When using Philips Hue make sure that the xxter unit and the Hue network module bridge are both connected to the same internal network xxter installation manual 13 enOcean In case you are using a xxter model with enOcean support HE01 HCE01 of HKE01 then the enOcean antenna has to be connected to the serial port RS232 on the front side of the device see Image 6 1 Make sure the power adaptor of xxter is not connected 2 Connect the serial connector of the ANEO1 to the serial port RS232 of the xxter unit 3 Connect the electrical splitter cable to the xxter unit 4 Connect the power adaptor to the electrical splitter cable Image 6 enOcean connection schema The enOcean ANEO1 antenna is equipped with a repeater function The ANE0O1 repeater has three different settings 1 No repetition stan
15. n environment the installation professional also has access to the section for the end user 6 xxter installation manual 3 Project configuration Every project is built from components and every component has a type aname and group addresses to identify the component The type of the component has to correspond with the characteristics of the home automation component that is used For an overview and explanation of the different component types see addendum A The name of a component is important for identification by the end user so he or she understands which component was intended for instance Kitchen table ceiling light The end user can always use another description when including the component in the visualisation For the technical identification of the component group addresses are used The sending group contains the group address to which a telegram should be sent There is a maximum of one sending group address per component The status group s contain one or more group addresses to display the status of that component Often the sending group address is also a status group The value contains the value that should be sent or the value to which xxter should react The group addresses are used for all different protocols of home automation KNX DMX enOcean and Hue Details about these protocols can be found in the corresponding chapters later on in this manual Apart from these main settings y
16. nding enOcean telegrams in the configuration tool For a detailed explanation of the different types of enOcean telegrams and a complete overview of all steps to configure enOcean please refer to the separate enOcean manual on the website Here you can also find an overview of all enOcean components that are supported by xxter xxter installation manual 17 16801408 41 4Byte 4 Temperature and Humidity 02 Temperature Outside temperature and humidity meter ee d 11 Setting up Hue components Before using Hue components make sure that all Hue lights are correctly configured within the Hue system as described in the Hue manual s By using the Phillips Hue app you can see which Hue lights are configured and in which order On My xxter or in the xxter configuration tool you can then add the different Hue lights Always enter a Hue light in the sending group as well as the status group A Hue light is always defined in the following format HUE followed by the lamp number a and the desired command For instance HUE 1 S for switching lamp 1 on off The following commands are supported Switch S Switching on off RGB lighting R Red RGB lighting G Green RGB lighting B Blue Dimmer hue Hue colour Dimmer sat Saturation Dimmer bri Brightness To set a certain colour of a Hue light the RGB lighting component can be used or two separate dimmers for setting the Hue and Saturation 18 x
17. ou can set up whether xxter should perform a bridge function for a component between the different protocols for instance between KNX and enOcean For every component you can also select whether the component should be available for the end user to use as a scenario option or in the planner Normally all actuators that are used by regular switches in the house should also be available for scenarios and the planner e g lights curtains etc xxter installation manual 7 Projects can be configured through the central webpages of My xxter but also by using the configuration tool for installation professionals For teaching in enOcean telegrams the configuration tool is required You can find the tool on the downloads page for professionals within My xxter http www xxter com myxxter Demonstration project Name Demonstration project Number of actions 24 Send date group Send time group Sunrise group Sunset group Change Duplicate Delete Actions Cameras Commands Statistics Chart data enOcean telegrams Filter Show all Type Name dered Read Delete Switch gt No Bridge i Add Update Wind speed gt Wind speed 2 4 0 No Bridge Temperature gt Temperature inside 2 2 17 No Bridge Temperature gt Temperature outside 2 4 6 No Bridge Switch AlertServiceTest 8 579 8 5 9 l No Bridge Switch Kitchen working area ayajo 8 4 0 No Bridge Switch Living room ceiling light 8 4 3 8 4
18. teach in enOcean components the configuration tool is used You can find the tool on the downloads page on the professional section of My xxter http www xxter com myxxter In the configuration tool open a project download a project from the server or create a new project Enter the IP address of the xxter device in the tool s settings and connect to the device using the right most button in the toolbar the enOcean symbol Now the configuration tool can receive enOcean teaching telegrams The configuration tool will automatically add all received teach in and switch telegrams to the project on the fourth tab of the tool oo og ll atti s File View Settings Help Ose aeu a Project settings Actions Cameras enOcean RORG enOcean id 5 type Name Outside temperature and humidity meter en Switch button lending Function 4Temperature and Humidity Manufacter id 16801408 Type Channel 41 4byte 02 Temperature range 20 to 60 C and humidity 0 100 X enOcean Manufacter id Channel RORG type Function Type Name 2212096 39 Switching All functions All types enOcean switch 0 1 4Byte 38 Central command 02 Central dimmiLamp in corner value 0 0 Switching All functions All types Actuator on off 16997120 99 4Byte 12 Automated meter reading 01Electridty Electricity meter wb wne Image 8 teaching in enOcean telegrams Of course you can also add se
19. xter configuration overview The xxter configuration is created in four separate parts devices projects profiles and pages The device is the xxter unit itself The unit should be registered for the installation professional as well as the end user and is the basis for the rest of the configuration The project contains the actual technical configuration wherein the home automation components are defined and additional other features like for instance cameras By connecting a project to a device the project will be enabled for that device The profile describes the visualisation for smartphone and tablet By connecting a profile to a device the visualisation will become available for that device The pages are the different visualisation screens to control a profile Every profile has one page as start up page and any number of following pages As an installation professional you can configure the project en connect it to a device Of course itis possible to manage multiple projects and devices for one professional As an end user you can manage the profile and the subsequent pages It is possible to use multiple devices and profiles next to each other On the smartphone or tablet you can choose the profile you want to load for the specific device This manual describes the configuration of the device and the project For more information about managing profiles and pages please refer to the user manual In the configuratio
20. xter installation manual 12 Initialization Now the installation and configuration is complete it can be loaded onto the xxter device Access the device on the local network with your web browser using the IP address of the xxter device and log in Then open the Settings system page and in the Configuration section press the Load button to load the personal configuration onto the device When the configuration is successfully loaded the technical installation is completed Now using the user manual the visualisation for the smartphone or tablet can be created and the xxter app installed and set up to connect to the xxter device We recommend that the installation professional always creates an initial visualisation for or together with the end user 13 Using xxter over the Internet When the end user wants to use xxter not only from within the home or office but also over the Internet the router firewall or modem has to be configured to allow this The following port has to be forwarded to the internal IP address of the xxter device port forwarding TCP 2199 Please refer to the manual of the router firewall or modem of the end user how this should be done It is also possible to configure the xxter device to work on a different port number On the webpage of the xxter device open the Settings basic page and change the Secure application port Remember that the alternate port number should also b

Download Pdf Manuals

image

Related Search

Related Contents

Novell ZENworks Endpoint Security Management 3.5 User's Manual  PA Series Precision Analytical Balances USER MANUAL    SK13P  CYWM6934 WirelessUSB LS(TM) Radio Module  ficha técnica producto: sellador antihongos antisalitre fungicida el  Datalogic Falcon X3  EZ Zone PM User Manual  Sennheiser HD 228    