Home

User's Manual - microSYST Systemelectronic GmbH

image

Contents

1. Inputs ST13 Inputs are set via Vout with 24 VDC The common GND pin is used for the connection of initiators Pin Labeling Assignment 1 Vout 2 E1 Input 1 3 Vout 4 E2 Input 2 5 Vout 6 E3 Input 3 7 GND SD Slot Slot for commercial SD cards with up to 2 GB memory The SD cards must be for matted with the FAT file system Page 16 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mitas sers2 1 Ps Control Panel with 34 Buttons 34 LEDs LC Display and Profibus DP Interface 4 2 Switches Factory Settings grey coloured Profibus Interface 1 internal donotchange X as eet ee DIP Switch Function 1 DPaddress ID no 2 0 ib 2 DPaddress ID no 2 0 25 3 DPaddress ID no 0 J 4b 4 DPaddressiDno 2 0 amp 5 DPaddress ID no 0 116p 6 DPaddressiDno 0 329 i BRaddress D nos o 9 jo o o 2 reserved internal Profibus set 2 bus termination Only DP addresses from 0 126 are valid At the beginning and at the end of the Profibus cable a bus termination must be set either internal or external s3 DIP Switch Function OFF _ ON 2 internal do not change E 5 eat co not change o o 6 reserved XT o7z reserved XT o 8 reseve PX
2. Albert Einstein StraBe 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST ot 1 mitas ss732 T PB Control Panel with 34 Buttons 34 LEDs LC Display and Profibus DP Interface 3 2 4 DP Output Data Byte Bit7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Index it it it it it it it it 0 LED 8 LED 7 LED 6 LED 5 LED 4 LED 3 LED 2 LED 1 1 LED 16 LED 15 LED 14 LED 13 LED 12 LED 11 LED 10 LED 9 2 LED 24 LED 23 LED 22 LED 21 LED 20 LED 19 LED 18 LED 17 3 LED 32 LED 31 LED 30 LED 29 LED 28 LED 27 LED 26 LED 25 A LED lights if it s corresponding bit is set 3 2 5 DP Input Data Byte A i r Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Index 0 Button 8 Button 7 Button 6 Button 5 Button 4 Button 3 Button 2 Button 1 1 Button 16 Button 15 Button 14 Button 13 Button 12 Button 11 Button 10 Button 9 2 Button 24 Button 23 Button 22 Button 21 Button 20 Button 19 Button 18 Button 17 3 Button 32 Button 31 Button 30 Button 29 Button 28 Button 27 Button 26 Button 25 If a button is pressed its corresponding bit is set Page 13 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mitas ss732 T PB Control Panel with 34 Buttons 34 LEDs LC Disp
3. In Test Mode a LED lights up if its corresponding button is pressed The text with message number 1023 is shown and can be scrolled with the buttons The operation mode Legacy supports only the lower 32 buttons and LEDs Page 17 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mitas BB732 1 PB Control Panel with 34 Buttons 34 LEDs LC Display and Profibus DP Interface BBT32 Control Board HEX Switch Doo Funcion 7 Legac ADR 10 o ooy Cd oo T S S IL Eah ESUAaO sw Operation Mode Standard 6 internal do notchange XT O7 ST S T sll 7 X o 8e Jo t l 4 3 LEDs Frontside LEDs lights static green if the supply power 24 VDC is connected lights static green if the supply power 5 VDC is internally created lights yellow at every received frame lights red if it came to communication problems Profibus LEDs LED Monitor red ERROR Blinking no response from the BBT32 control board ON no Profibus DP connection OFF everything is OK green STATUS OFF controller not started hardware error ON controller started Temporary OFF flickering BBT32 communication cycle Page 18 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de in
4. LED 8 LED 7 LED 6 LED 5 LED 4 LED 3 LED 2 LED 1 LED 16 LED 15 LED 14 LED 13 LED 12 LED 11 LED 10 LED 9 LED 24 LED 23 LED 22 LED 21 LED 20 LED 19 LED 18 LED 17 LED 32 LED 31 LED 30 LED 29 LED 28 LED 27 LED 26 LED 25 S o Display ON Output 3 Output 2 Output 1 LED 34 LED 33 Message Message Message Message Message Message Message Message Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 LED A LED lights if it s corresponding bit is set Message A message is called with a message number It is defined with 10 bits Display ON The display is switched on if the bit is set Output An output is set with its corresponding bit Page 9 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de mitas ss732 T PB Control Panel with 34 Buttons 34 LEDs LC Display and Profibus DP Interface 3 1 5 DP Input Data A1 A2 A3 A4 A5 A6 microSYST Byte 0 Byte 1 B 2 B 3 B 4 B 5 B 6 B 7 Device Status RES A1 A2 A3 A4 A5 A6 00 no valid response from the BBT32 control board to the Profibus interface 014 response exists and is OK 00 reserved Response bytes according to the following table if enabling issued else 0 each Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Button 8 Button 7 Butto
5. observance may lead to malfunction ing or destruction of the device Under certain circumstances electrical shock fire and explosion may occur as well Information concerning allowable ambi ent conditions including recommended temperature ranges can be found in the chapter entitled Technical Information The control panel may not be placed into service if the device and or the power cable are known to be damaged Do not attempt to repair the device yourself The guarantee is rendered null and void if the device is tampered with by unauthorized persons Page 22 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mitas sers2 1 Ps Control Panel with 34 Buttons 34 LEDs LC Display and Profibus DP Interface 6 2 Warranty Liability For the product liability is assumed for defects which existed at the delivery date according to our General Terms and Conditions Technically changes as well as errors are excepted A claim for delivery of a new product does not exist The buyer has to check the received product immediately and indicate evident defects at the latest 24 hours after detection Non observance of notification requirements is equated with acceptance of the defect Not immediately visible defects have to be indicated immediately after their per ception too Generally defects and their sympto
6. 4 Buttons 34 LEDs LC Display and Profibus DP Interface 2 2 LCD Display e 2 lines with 24 characters each e white backlight e 2 buttons and for scrolling multiline messages 2 3 SD Card Type commercial cards up to 2 GB Formatting FAT 1024 messages storable A message can have up to 8 lines with 24 characters each 2 4 CSV File Messages can be created in an Excel table The file name must be Texte csv The first column contains the message number 0 to 1023 The second column contains the first line of the message 24 characters max The third column contains the second line of the message 24 characters max The ninth column contains the eighth line of the message 24 characters max Lines without message number in the first column are not evaluated So even headlines are possible The message number must be ascending Example Alert Line 1 Line 2 Line 3 Line 4 Line 5 Line 6 Line 7 Line 8 0 Texti Line1 Text1 Line2 Text1 Line3 Text1 Line4 Text1 Line5 Text1 Line6 Text1 Line7 Text1 Line8 Text2 Line1 Text2 Line2 Text2 Line3 Text2 Line4 Text2 Line5 Text2 Line6 Text2 Line7 Text2 Line8 1 2 Text3 Line1 Text3 Line2 Text3 Line3 Text3 Line4 Text3 Line5 Text3 Line6 Text3 Line7 Text3 Line8 3 Text4 Line1 Text4 Line2 Text4 Line3 Text4 Line4 Text4 Line5 Text4 Line6 Text4 Line7 Text4 Line8 Error L
7. 8 output and 8 input bytes are used Remark In principle the Profibus interface is able to control up to 8 BBT32 de vices via RS485 422 However this is not described in this manual Here only one BBT32 device is connected with the interface 3 1 2 Diagnosis Data The interface does not support any extended diagnosis data Default diagnosis is utilised 3 1 3 User Parameter Data User parameter data are not utilised by the interface However a test is run to de termine whether or not user parameter data are transferred by the Profibus mas ter If user parameter data are transferred Profibus initialisation is disabled and the slave s parameters must be reconfigured Note Standard parameters configuration is required and is normally installed by the util ised DP configurators Page 8 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de mitas ss732 T PB microSYST Control Panel with 34 Buttons 34 LEDs LC Display and Profibus DP Interface 3 1 4 DP Output Data D1 D2 D3 D4 D5 D6 Byte 0 Byte 1 B 2 B 3 B 4 B 5 B 6 B 7 Enabling RES D1 D2 D3 D4 D5 D6 00 not issued 00 reserved Data bytes according to the following table gt D1 6 0 014 issued Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
8. age temperature Profibus DP 9 6 kBaud 12 MBaud 0 126 8 x4 2 2 Buttons 8 x 4 2 2 LEDs 4 LEDs for status display 2x POWER FAULT und DATA LCD two lines with 24 characters each white LED backlight quantity 3 24 VDC with additional common OV connection quantity 3 24 VDC max 200 mA per output 1024 messages on a SD card max 2 GB 1 message can extend up to 8 lines labeling strips 24 VDC 20 protected against polarity reversal max approx 200 mA at 24 VDC operating voltage current for the digital outputs depending on the load panel mounting front panel IP65 without option housing powder coated sheet steel colour RAL 7016 anthracite housing with pole powder coated sheet steel colour RAL 7016 anthracite see chapter Mounting Options O to 50 25 to 60 Page 5 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mitas BB732 1 PB Control Panel with 34 Buttons 34 LEDs LC Display and Profibus DP Interface 2 1 LED Button Assignment 33 34 KEEKEEKE Seae0 08088 AF POWER 24 VDC by DATA by POWER 5 VDC bs FAULT Page 6 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mitas ss732 T PB Control Panel with 3
9. den Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de
10. erview microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de 19 19 20 21 22 22 23 24 Page 3 microSYST mitas BB732 1 PB Control Panel with 34 Buttons 34 LEDs LC Display and Profibus DP Interface 1 General The mitas BBT32 T DP control panel reduces previous wiring and installation efforts to a minimum 34 buttons and LED indication form the concept of the basic unit This unit is oper ated via a Profibus DP interface Fault or information messages can be displayed on the integrated LCD display Multi line messages can be read with the buttons and The messages must be stored in a CSV file on a SD card Additionally 3 digital inputs and 3 digital outputs are available e g to connect a key switch Page 4 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mitas sers2 1 PB Control Panel with 34 Buttons 34 LEDs LC Display and Profibus DP Interface 2 Technical Information General Specifications Interface Baud rate Addresses Buttons LEDs Display Digital inputs Digital outputs Text memory Labeling Operating voltage Power consumption Mounting Protection Housing Housing dimensions Operating temperature Stor
11. fo microsyst de microSYST mitas BB732 1 PB Control Panel with 34 Buttons 34 LEDs LC Display and Profibus DP Interface 5 Mounting Options 5 1 Panel Mounting Page 19 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mitas BB732 1 PB Control Panel with 34 Buttons 34 LEDs LC Display and Profibus DP Interface 5 2 Housing 375 Page 20 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mitas BB732 1 PB Control Panel with 34 Buttons 34 LEDs LC Display and Profibus DP Interface 5 3 Pedestal 250 210 Page 21 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mitas ss732 T PB Control Panel with 34 Buttons 34 LEDs LC Display and Profibus DP Interface 6 Appendix 6 1 Maintenance and Care Observe the following instructions Display quality is impaired by direct illumination with bright light sources and or direct sunlight The control panel must be switched off before cleaning Protect the control panel from excessive humidity extreme vibration direct sunlight and extreme temperatures Non
12. ine 1 Line 2 Line 3 Line 4 Line 5 Line 6 Line 7 Line 8 4 Text5 Line1 Text5 Line2 Text5 Line3 Text5 Line4 Text5 Line5 Text5 Line6 Text5 Line7 Text5 Line8 5 Text6 Line1 Text6 Line2 Text6 Line3 Text6 Line4 Text6 Line5 Text6 Line6 Text6 Line7 Text6 Line8 2 5 Starting Procedure The display shows a starting message with the versions number and the interface pa rameters not relevant for Profibus users Page 7 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mitas BB732 1 PB Control Panel with 34 Buttons 34 LEDs LC Display and Profibus DP Interface 3 Profibus DP Interface The device has the operation modes Standard and Legacy The selection happens with several DIP switches see below The factory setting is Standard The Profibus controlling depends on operation mode and is described in the fol lowing chapters 3 1 Operation Mode Standard This operation mode supports all functions of the control panel 3 1 1 Configuration Data For configuration please use the enclosed GSD file IFBBT32T GSD from 14 08 2012 For the control panel use the following modules e Index 0 Steuerung Index 0 0x31 2 I O bytes e Index 1 BBT32 T Index 1 bis 8 0x35 6 I O bytes So at the whole
13. lay and Profibus DP Interface 4 Connector Pin Assignments Settings scon ADR 10 ADR m01 IA Serial Config R Outputs _ Vin Vout GND 24U GND 24U OO L IN OUT Profibus Profibus SUB D loo OO A B A B Rafa RATX RWT RwTx ST1 A Profibus 4 IN OUT microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de B 2 a Page 14 microSYST mitas BB732 1 PB Control Panel with 34 Buttons 34 LEDs LC Display and Profibus DP Interface 4 1 Connectors Vin Vout power supply Connect the power supply 24 VDC with Vin Vout serves for forwarding the power Profibus IN OUT Connectors for the Profibus IN is the input OUT the output Profibus SUB D Alternative connector for the Profibus Assignment Oooo y Oooo y 4 RTS O GND electrically isolated 5V electrically isolated O Doo Outputs ST12 The outputs supply 24 VDC maximum current load is 200 mA per output Pin Labeling Assignment 1 GND 2 A1 Output 1 3 GND 4 A2 Output 2 5 GND 6 A3 Output 3 Page 15 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mitas BB732 1 PB Control Panel with 34 Buttons 34 LEDs LC Display and Profibus DP Interface
14. microSYST mitas se132 1 PB Control Panel with 34 Buttons 34 LEDs LCD Display and Profibus DP Interface User s Manual microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de mitas ss732 T PB Control Panel with 34 Buttons 34 LEDs LC Display and Profibus DP Interface Table of Contents 1 GENERAL 2 TECHNICAL INFORMATION 2 1 LED Button Assignment 2 2 LCD Display 2 3 SD Card 2 4 CSV File 2 5 Starting Procedure 3 PROFIBUS DP INTERFACE 3 1 Operation Mode Standard Configuration Data Diagnosis Data User Parameter Data DP Output Data DP Input Data Examples WWWWWW le A A A at A aOahWNDM 3 2 Operation Mode Legacy 3 2 1 Configuration Data 3 2 2 Diagnosis Data 3 2 3 User Parameter Data 3 2 4 DP Output Data 3 2 5 DP Input Data 4 CONNECTOR PIN ASSIGNMENTS SETTINGS 4 1 Connectors 4 2 Switches 4 3 LEDs microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de 15 17 18 microSYST Page 2 microSYST mitas ss732 T PB Control Panel with 34 Buttons 34 LEDs LC Display and Profibus DP Interface 5 MOUNTING OPTIONS 5 1 Panel Mounting 5 2 Housing 5 3 Pedestal 6 APPENDIX 6 1 Maintenance and Care 6 2 Warranty Liability 6 3 Versions Ov
15. ms must be described as accurately as pos sible in order to allow for reproducibility and elimination The buyer must provide for access to the relevant device and all required and or useful information at no charge and must make all of the required data and machine time available free of charge The guarantee does not cover defects which result from non observance of the prescribed conditions of use or from improper handling If the device has been placed at the disposal of the buyer for test purposes and has been purchased subsequent to such testing both parties agree that the product is to be considered used and that it has been purchased as is No guarantee claims may be made in such cases The General Terms and Conditions of microSYST Systemelectronic GmbH in current version apply as well Page 23 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mitas sers2 1 Ps Control Panel with 34 Buttons 34 LEDs LC Display and Profibus DP Interface 6 3 Versions Overview Remark Description 11 06 10 English version 25 08 10 Additional information 26 08 12 Nickl Changes because of new Profibus interface HE1003 19 03 13 Company address warranty changed 22 10 13 Logo Certified per DIN EN ISO 9001 Page 24 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Wei
16. n 6 Button 5 Button 4 Button 3 Button 2 Button 1 Button 16 Button 15 Button 14 Button 13 Button 12 Button 11 Button 10 Button 9 Button 24 Button 23 Button 22 Button 21 Button 20 Button 19 Button 18 Button 17 Button 32 Button 31 Button 30 Button 29 Button 28 Button 27 Button 26 Button 25 o sa Display ON Input 3 Input 2 Input 1 Button 34 Button 33 Message Message Message Message Message Message Message Message Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Button If a button is pressed its corresponding bit is set Message Number of current displayed message 10 bits Display ON The display is currently switched on if this bit is set Input A set bit means the input is set Page 10 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mitas sers2 1 Ps Control Panel with 34 Buttons 34 LEDs LC Display and Profibus DP Interface 3 1 6 Examples Output Data Switch on LED 10 01 00 00 02 00 OO 00 00 Set output 1 01 00 00 00 00 OO 04 00 Switch display on and show message 3 01 00 00 00 00 00 20 03 Input Data Button 4 is pressed 01 00 08 00 00 00 00 00 Input 3 is set 01 00 00 00 00 00 10 00 Page 11 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de inf
17. o microsyst de microSYST mitas sers2 1 Ps Control Panel with 34 Buttons 34 LEDs LC Display and Profibus DP Interface 3 2 Operation Mode Legacy This operation mode emulates the functionality of the control panel mitas DP BBT32 32 buttons 32 LEDs which is not available anymore former designa tion was also BBT32_DP The additional buttons and the LCD display at the top of the control panel can then not be used Please consider the necessary DIP HEX switch settings which differ from the factory settings see below 3 2 1 Configuration Data For configuration please use the enclosed GSD file DPIFBBT 12M GSD or DPIFBBT GSD from 05 02 2004 each For the control panel use the following module e DPIFBBT32 0x10 0x10 0x10 0x10 0x20 0x20 0x20 0x20 So at the whole 4 input and 4 output bytes are used 3 2 2 Diagnosis Data The interface does not support any extended diagnosis data Default diagnosis is utilised 3 2 3 User Parameter Data User parameter data are not utilised by the interface However a test is run to determine whether or not user parameter data are transferred by the Profibus master If user parameter data are transferred Profibus initialisation is disabled and the slave s parameters must be reconfigured Note Standard parameters configuration is required and is normally installed by the utilised DP configurators Page 12 microSYST Systemelectronic GmbH

Download Pdf Manuals

image

Related Search

Related Contents

A120786 - Bartscher GmbH  A200SP Service Manual.qxd  DeLOCK 65028  Sanyo DP55360 User's Manual  

Copyright © All rights reserved.
Failed to retrieve file