USER MANUAL
Contents
1. Areas with acute trauma Recent scars Body areas near metallic implants and prostheses such as orthopedic plates screws nails and other osteosynthetic devices when using monophasic current Interferential Currents program or continuous current lontophoresis Currents program The Globus Electrostimulator is not intended for use in water since it is not protected against infiltration Moreover do not use the stimulator in the presence of inflammable gas especially oxygen for medical purposes It is recommended that the Globus Electrostimulator be used with caution in persons with capil lary fragility to avoid excessive capillary damage Potential adverse effects Skin irritation may occur in persons with particularly sensitive skin In case of allergic reaction to the electrode adhesive stop use of the electrostimulator and con tact a physician If during stimulation tachycardia or extrasystole occurs stop use of the elec trostimulator and consult a physician Special precautionary measures for urological treatments Patients with urinary tract infections should first be treated medically before undergoing urological electrostimulation Special uro logical probe electrodes are required for these programs After urological electrostimulation before touching or removing the probe electrodes turn off the instrument or set the intensity of both channels to 0 MA Urological electrostimulation is contraindicated in patients with
2. Extra urethral urinary incontinence Fecal incontinence Serious urinary retention in the upper urinary tract Complete peripheral denervation of the pelvic floor Total or partial prolapse of the uterus or vagina in these patients the electrostimulator may be used with extreme caution REV 03 09 03 CARE MAINTENANCE AND DISPOSAL N Recommendations for maintenance and use of the Globus Electrostimulator In case of damage to the instrument s exterior this must be replaced before using the elec trostimulator again In case of presumed or real failure do not open the instrument or attempt to make repairs yourself Repairs may only be made by an authorized service center Protect the electrostimulator from violent blows shaking and overturning which may damage the instrument and lead to malfunction in the long term even though no immediate failure is apparent Protect the electrostimulator from splashes of water heat sources dust humidity direct expo sure to sunlight and strong magnetic fields The instrument should not be used when wrapped or covered Do not clean the instrument with solvents such as paint thinner gasoline kerosene alcohol and other chemicals Clean the instrument and cables with a soft cloth dampened with water Prior to using the instrument after a long period of disuse check that the electrostimulator and the battery are functioning correctly contact an authorized service center Do not use the
3. QUADRICEPS INTERNAL THIGH Work position Work position GLUTEUS MUSCLES zus MUSCLES CERVICAL VERTE PERIARTHRITIS OF SCAPEL OR HUMERUS Work position Work position REV 03 09 03 ELECTRODE PLACEMENT EPICONDYLITIS EPICONDYLITIS SCIATICA KNEE Work position Work position REV 03 09 03 ELECTRODE PLACEMENT for microcurrents Work position rn Work position nm Work position Work position Work position REV 03 09 03 ELECTRODE PLACEMENT for microcurrents Work position Work position 40 os Work position EN Work position nm Work position OR Work position REV 03 09 03 ELECTRODE PLACEMENT with accessories 26 Work position REV 03 09 03 WARRANTY TERMS This product is guaranteed to the original purchaser client for a 24 month period from the purchase date against material defects and manufacturing pro blems provided that the instrument is used properly and maintained in normal conditions To obtain service under warranty the following con ditions must be met 1 The products must be delivered for repair in their original packaging the client must cover all shipping expenses 2 Service under warranty requires presentation of a valid receipt or invoice that demonstrates the pur chase date 3 Service does not change the date of warranty expiration and does not imply r
4. instrument while the batteries are being charged The electrostimulator is connected to the electrical line through its own power supply Before attaching the electric current be sure that your electrical system conforms to national stan dards Do not use the electrostimulator together with other electronic equipment above all those used to support vital functions Store in the supplied carrying case in conditions of 20 85 relative humidity and 5 45 Recommendations for maintenance and use of electrodes and cables Clean and dry the skin prior to attaching the electrodes to ensure good conductivity The electrodes are designed to be used for 25 30 applications on a single person After using the single user reusable electrodes protect the adhesive with the supplied film and store them in a sealed clean plastic bag Do not permit the electrodes to attach to each other Do not use cables or electrodes that show signs of wear or are not perfectly adherent to the skin Discard them and obtain manufacturer s original replacement parts If you use electrodes that are not self adhering clean the surface with water before use Store in the supplied carrying case in conditions of 20 85 relative humidity and 87 457 Recommenddations for disposal Do not burn Dispose of the instrument according to national rules for the elimination of electronic instru ments WARNINGS PRECAUTIONARY MEASURES The electrosti
5. is not necessary to set an intensity value in microampe res because these are preset and automatically activated for all phases See section NOTES ON USING THE PROGRAMMES WITH MICROCURRENT Open circuit The Electrostimulator has a device that controls the current supply If the operator increases the intensity level above 10 MA and the circuit is open cables are not connected to the appa ratus and electrodes are not applied to the skin the electrostimulator immediately brings the intensity to MA Therefore before beginning a program make sure that the cables are con nected to the apparatus and that the electrodes are in good condition and are applied cor rectly to the area to be treated NOTE Use the Microcurrents programs only on channels 1 and 3 with the gray cables If the cables are not connected or they are they wrong type the Electrostimulator will not start the program Check the cables and the connections REV 03 09 03 1 5 PROGRAMS LIST FITNESS amp SHAPE Demo Mass Development Motor Point Pen Body Sculpting MEN WOMAN Definition Firming Jogging Active Rest Anaerobic Fitness Maximum Force Muscular Initiation Aerobic Resistence Aerobic Fitness Decontracture Cramp prevention Bio Pulse firming Sculpting One type of program may offer more than Sculpting Bio Pulse one difficulty level or body area to exercise Toning PROGRAMS LIST BEAUTY_AESTHETICS MEN WOMAN Lipolysis post birth Lipolysis Firming post birth Mass
6. programs CH 1 H CH2 CH3 CH4 Use channels 1 and 3 with the gray cables for the Microcurrents MCR program REV 03 09 03 KEYBOARD INCREASE OR DECREASE INTENSITY FUNCTION KEY LEFT BACK KEY DOWN DEL KEY INTENSITY FUNCTION LEFT BACK DOWN DEL TIME UP SAVE RIGHT USER ON OFF OK 3 10 TIME 2 2 KEY UP SAVE KEY RIGHT USER KEY ON OFF OK KEY Increase or decrease the intensity of the corresponding channels Changes the duration of a phase when pressed alone Changes the function of other buttons when pressed simulfaneously Move the selection to the left 3 gt Return to the previous selection 3 during a program Return to the previous phase Move the selection down During a program simultaneously decrease the intensity of the 4 chan nels During a program displays the remaining total time or that of the ongoing phase Move the selection to the top During a program simultaneously increase the intensity of the 4 channels Move the selection to the right 3 during a program gt skip to the subsequent phase Confirms the selection of a program in progress and activates the pause 3 gt Power on Power off Activate the function by pressing the key for 3 seconds REV 03 09 03 USING THE STIMULATOR Before you start Read this operating manual with attention Carefully examine the electrostimulator and supplied parts to ensure absence of damage Check that the electrostimulato
7. to select the area of the second program channels 3 and 4 and confirm with OK 6 Use the UP and DOWN keys to select Man or Woman for the second program 7 Use the UP and DOWN keys to choose the body part for treatment for the second selected pro gram 8 Use the UP and DOWN keys to select the specific program channels 3 and 4 and confirm with OK MULTIPLE PROGRAMS USING THE PROGRAMS LIST MENU Access 2 2 Mode from the Program List menu 1 To select the first program position the cursor on Program List on the main menu and confirm with OK 2 Use the UP and DOWN kevs to select the desired program area and confirm with OK 3 Use the UP and DOWN keys to select the program variable and confirm with OK 4 Use the UP and DOWN keys to select the desired program name Choose Continue with 2 2 rather than to execute multiple programs 5 Follow steps 5 8 above At the end of step 8 start both programs by regulating the intensities of the different channels using the INCREASE and DECREASE INTENSITY keys REV 03 09 03 1 3 ADVANCED MENU The advanced menu comprises the following entries MODE2 2 User Selection FUNCTION The function User selection inside the Set up area allows the special functions to be used Last 10 Programs Favourites and AUTO STIM in a personalized way The user who selects his her own User can save his her favourite programmes in the Favourites memory These pro grammes will be avail
8. Any type of sequential electrostimulation Aesthetic care Sports training The Electrostimulator may be used with or without the supervision of physicians or paramedic personnel TECHNICAL CHARACTERISTICS EMS and TENS Channels available Constant current Intensity Wave form Working frequency Recovery frequency Impulse amplitude Working time Recovery time Frequency modulation range Amplitude modulation range Microcurrents Channels available Constant current Minimum frequency Maximum frequency Minimum intensity Maximum intensity Amplitude Channels 1 2 3 4 Yes 0 120 mA with 1000 Ohm load Rectangular biphasic symmetrical compensated 0 3 150 Hz 0 3 150 Hz 50 450 m s 1 30 s 0 1 min Continuous variation from 1 to 150 Hz Minimum modulation time 3 s Continuous variation from 50 to 450 ms Minimum frequency 1 Hz Maximum frequency 150 Hz Channels 1 3 Yes 0 2 pps 200 pps O mA 1000 Ohm 10 mA steps 800 mA 1 250 s REV 03 09 03 7 Specifications Batteries Rechargeable Ni MH accumulator 7 2 V 1 5 Ah Globus model Power supply Modello Globus Globus ILD41V 0720200 Exterior Acrylonitrile butadiene styrene ABS food contact grade Protection level IP 20 Size 160 mm x 99 mm x 35 4 mm Weight 404 gr Certifications EU Medical Device Directive MDD 93 42 EEC BATTERY CHARGING The Globus Electrostimulator is furnished with a set of rechargeable nickel metal hydrate bat ter
9. ELECTROSTIMULATORS USER MANUAL ACTIVA 500 Rev 03_09 03 DEAR CLIENT THANK YOU FOR CHOOSING GLOBUS WE WILL BE PLEASED TO PROVIDE HELP AND SUGGESTIONS ABOUT USING OUR PRODUCTS The GL4 electrostimulators are produced by DOMINO s r l 31020 San Vendemiano TREVISO Phone 39 0438 793052 Fax 39 0438 796463 E Mail info domino tv it The Globus product ACTIVA 500 is esclusively distributed by GLOBUS ITALIA S r l Phone 0438 7933 www globusitalia com info globusitalia com This product has been manufactured according to the technical regulations in force and is certified according to Directive 93 42 EEC for medical devices by CERMET Scr authorization no 0476 in order to ensure the product s safety To maintain the maximum level of safety operate the instrument according to instruc tions and restrictions given in this operating manual Neither the producer nor distri butor is responsible for any damage or injuries resulting from a use different from that indicated in this operating Manual REV 03 09 03 SUMMARY SUMMAR we aan anne arena nee 3 INCLUDED MATERIALS 4 CONTRAINDICATIONS 5 CARE MAINTENANCE AND DISPOSAL 6 WARNINGS 6 TECHNICAL CHARACTERISTICS 7 Specifications Program characteristics BATTERY CHARGING 8 DUPLA TESS en oe E
10. RUSO 9 REL DORR ee 10 USING THE STIMULATOR 1 SPECIAL FUINCTIONS van 99 8 12 Last 10 Executed AUTO STIM Automatic 2 2 Mode simultaneous stimulation 13 ADVANCED MENU 14 INTENSITY OF STIMULATION 15 Open circuit PROGRAMS WS vereint nen onen ner 16 DESCRIPTION OF PAIN RELIEF TRATMENTS 17 NOTES ON THE USE OF PROGRAMMES LUN au 9 eU dc Cm 17 PROGRAMS LIST G PULSE 18 ELECTRODE 19 WARRANTY TERMS 27 FREQUENTLY ASKED QUESTIONS 27 REV 03 09 03 INCLUDED MATERIALS Each Globus Electrostimulator is supplied with the following material a GL4 Electrostimulator unit b Operating manual c Carrying case d Four 4 colored electrode connection cables Use these for the regular ectrical muscle stimulation EMS programs for transcutaneous electrical nerve stimulation TENS programs e Two 2 gray electrode connection cables Use these for the Microcurrents G PULSE f Four 4 reusable adhesive electrodes 5 x 5 cm2 g Four 4 reusable adhesive electrodes 5 x 9 cm2 h Battery charger i Warranty When you open the packing of your Globus Electrostimulator please verify that all the equip ment listed above is present If any material is missing please cont
11. able only for that specific user The same applies to the Last 10 Programmes function NOTE The user selected the last time appears each time the machine is turned on SETUP Light up Timer FUNCTION The Light up Timer function can be found inside the Set up area and allows the duration of back lighting in stand by mode to be varied using the Up and Down keys Contrast FUNCTION The Contrast function present inside the Set up menu allows the level of contrast on the dis play to be varied using the Up and Down keys Language Selection FUNCTION The Language Selection function inside the Set up area allows 4 different languages to be selected using the Up and Down keys Confirm the selection with OK Service Sounds FUNCTION The Service Sounds function present inside the Set up area allows the acoustic beep emit ted by the machine to be enabled ON or disabled OFF Timer FUNCTION The Timer function inside the Set up area allows a period of time in minutes to be set using the Up and Down keys after which the machine if not used will turn off 14 REV 03 09 03 INTENSITY OF STIMULATION The current intensity necessary to obtain muscular contraction is personal and depends on the position of the electrodes the underlying adipose tissue layer sweating the presence of hair on the area to be treated etc For these reasons the same current intensity can generate dif ferent feelings from pers
12. act your retailer immedia tely Please also check the integrity of the stimulator and the supplied electrodes and cables Electrodes The supplied electrodes are intended for use on a single person They are self adhesive reusable and do not require gel The electrode cable is female The electrodes are labeled CE in compliance with Directive 93 42 EEC for medical devices STANDARD SYMBOLS The instrument is in accordance with European Union norms and thus carries the CE label for medical devices of class I and type BF The battery charger is also class Il The external battery charger is class Il Attention read the instruction The presence of this symbol on your instrument indicates that it conforms to the require C ments of Directive 93 42 EEC for medical devices The authorizing organism is no 0476 0476 A Type BF applied parts floating circuits Isolation class 11 Power on Power off A REV 03 09 03 CONTRAINDICATIONS A Use of this Globus Electrostimulator is contraindicated in persons with the following conditions Pregnancy Pacemakers Pain of undetermined etiology Cancer if permission from an oncologist has not been obtained Urinary and pelvic conditions as described below Moreover the Globus Electrostimulator is NOT to be used to stimulate Anterior part of the neck carotid sinus Eyes Genitals Brain Area Sores and skin affected by dermatological disease
13. age Relax Bio Pulse Definition Toning massage Energetic massage One type of program may offer more than Connective massage one difficulty level or body area to exercise Figure PROGRAMS LIST PAIN ANTALGIC Endorphinic Tens Modulated TENS Cervical pain Menstrual PAin Knee pain Acute antalgic TENS Ankle pain Chronic antalgic TENS Chronic pain PROGRAMS LIST VASCULAR Drainage Venous insufficiency Copillarization Vascularisation Drainage Bio Pulse Drainage post birth One type of program may offer more than Swollen Arms one difficulty level or body area to exercise Arterial insufficiency PROGRAMS LIST FACE LOWER NECK MEN WOMAN Face capillaries Breast firming Liffing Effect Breast sculpting Face capillaries Lifting Effect 16 REV 03 09 03 DESCRIPTION OF PAIN RELIEF TREATMENTS Programs Name Programme When should it Electrode Time and effects be used placement intensity All the pain relief It uses the typical Against every kind of On the affected Intensity Non TENS programmes mechanisms of the pain It can be used area Cover the painful pins and nervous system in every time you need painful area with the needles sensation order to relieve to relieve pain electrodes acute and chronic Warning TENS pro pain Impulses are grammes relieve propagated through pain but do not eli the nerves in order to minate its cause If it stop the diffusion rou persists see the doc tes of the pain tor E
14. d to the outlets of channels 1 and 3 only The Microcurrents programs have prefixed intensity levels When a Microcurrents program is activated the electrostimulator automatically brings the intensity to the correct level This value should not be altered during execution of the program The Microcurrents programs cannot be run in the 2 2 mode with other treatments If one tries to select a Microcurrents program in 2 2 mode the electrostimulator will emit an error tone NOTE Use Microcurrents programs only on channels 1 and 3 and with the gray cables The word CABLE will appear on the display in case the wrong cable is used or if there is a bad connection The following Microcurrents programs are available NOTE For Microcurrents programs it is not necessary to set the current intensity because it is preset for all programs If the therapist advises you to change the preset values vary the intensity by using the UP and DOWN keys for 3 seconds REV 03 09 03 1 7 18 PROGRAMS LIST G PULSE Cellulite imperfection Stretch marks Neck amp shoulder microlifting Bio Skin Nails strengthening Face microlifting Wrinkles Bio peeling Skin Elasticity Eyes Wrinkles Haematoma Expression Wrinkles Breast Microlifting Using the G MicroTrode handpiece The G Microtrode handpiece is connected to the outlet 1 or 3 on the electrostimulator and must only be used with the G Pulse programmes Before commencing treatments on face place ge
15. els using the Up key on the Joy pad REV 03 09 03 1 1 Notes on program execution and modification Visualize parameters of program execution During execution the name of a program is shown on the top of the display In addition the display shows the body parts where the program can be used BODY means that it can be used on any muscular district the total number of phases the phase in progress full phase the remaining time of the phase in progress and the kind of current being employed e g EMS TENS For programs with intermittent stimulation the display shows the countdown in the cen ter and a graphic representation of the phase of work or rest Pause a program To pause a program press the OK key the word PAUSE appears on the display Pausing sets the intensity to zero and stops the clock To restart to the program press OK Resumption after a pause repeats the last interrupted cycle Stop a program If you need to stop a program before its end switch off the instrument by pressing the OK key for 3 seconds Visualize total time remaining single program During execution of a program the remaining time of the current phase in progress is displa yed To visualize the total remaining time press the TIME key During visualization of the total remaining time all indicators of the phases are lit After 2 s the remaining time of the phase in progress appears again Modify the parameters of a program Run Time single pr
16. enewal or extension of the warranty 4 If during a requested repair no defect is found the client will nonethe less be charged for expenses rela ted to labor involved 5 The warranty does not apply in case of damage to the instrument due to blows falls improper or incor rect use use of improper power supply accidents alterations changes or removal of guarantee seals and product infringement The warranty does not cover damage during shipping in inadequate pac kaging see Art 1 6 The warranty does not apply to the impossibility of using the product to other occasional or conse quential expenses or other purchaser expenses ATTENTION Before returning the instrument for repairs carefully read the instructions in this operating manual In case of device breakdown contact your retailer The producer reserves the right to apply at any moment any and all necessary modifications to improve the product s appearance and quality Distributed by Globus Italia Srl Tel 39 0438 793052 Tel 39 0438 7933 Fax 39 0438 796463 Fax 390438793363 E mail info domino tv it Emailiinfo globusitlia com Produced by DOMINO Srl The features and dimensions reported in this manual are not binding The producer reserves the right to make changes without notice REV 03 09 03 FREQUENTLY ASKED QUESTIONS Why when I increase the current intensity above 10 mA it returns immediately to 0 mA The Globus Electrostimulator c
17. hecks the level of sup plied current When the current intensity increases above 10 mA and the circuit is open the instrument brings it back to zero Therefore before starting any program check that the cables are connected and that the electrodes are positioned on the area to be treated In addition be sure that the electrodes are not worn because this could inhibit their ability to conduct current Where should one position the electrodes In the back of this manual there is a comprehensive electrode placement guide To verify the correct pla cement of electrodes use the special Find Motor Points Pen program or follow this empirical method place the electrode as indicated in the figures in the back of this manual start the stimulation with your hand move the electrode by sliding it along the muscle without remo ving it from the skin You will notice a change in con traction according to the different positions Place the electrode where the contraction is greatest Remember to decrease the intensity to zero 0 mA before moving the electrodes Is it possible to use the electrostimulator during men struation Electrostimulation may interfere in some way with men struation causing anticipation delay accentuation or reduction of the cycle however these effects are sub jective and highly variable Itisrecommended to avoid treatments in the abdominal zone during menstruation Is it possible to use the electrostimulator duri
18. ies which have high yield without memory effect Recharge the batteries when the bat tery light on the display indicates To charge the batteries turn off the electrostimulator and detach the electrodes Attach the supplied battery charger Globus model ILD41V 0720200 by inserting the plug in the appro priate inlet on the electrostimulator figure The LED on the charger lights when the connec tion is correctly made The first time the batteries are charged be sure not to interrupt the pro cess until complete about 10 hours If the electrostimulator is connected for longer periods but not greater than 72 h the batteries will not be damaged Do not use battery chargers other than the one supplied To replace the electrostimulators batteries contact an authorized service center Attention While the batteries are being charged the electrostimulator must not be connected to the electrodes If the battery charger is connected to the electrostimulator when the instrument is on it will turn off automatically If the battery charger the electrical cord or the connector show signs of wear or damage replace immediately 8 REV 03 09 03 DISPLAY Program Name BODY PART TREATED TYPE OF CURRENTS INDICATOR OF NUM an here PROCESS INDICATOR BATTERY INDICATOR TIME AND PHASE OF WORK OR REST CHANNEL 1 11 INTENSITY NOTES N UNE Use all 4 channels and the colored cables for EMS and TENS
19. l in both the conductor spheres While using the G Pulse programmes on the face a slight stinging sensation must be felt if nothing is felt at the preset intensity raise the value with the intensity increase keys or with the up key No stimula tion is necessarily felt in other parts of the body Eyes Wrinkles Expression Wrinkles Nails strengthening G MicroTrode Handpiece REV 03 09 03 ELECTRODE PLACEMENT 2 BICEPS MUSCLE ARM BICEPS BRACHII TRICEPS MUSCLE OF ARM TRICEPS BRACHII Work position Work position WRIST AND FINGER EXTENSORS WRIST AND FINGER FLEXORS Work position Work position DELTOID MUSCLES ANTERIOR Work position Work position REV 03 09 03 ELECTRODE PLACEMENT 7 8 DELTOID MUSCLES POSTERIOR GREATER AND SMALLER PECTORAL MUSCLES Work position Work position BREAST MUSCULUS LATISSIMUS DORSI Work position Work position TRA PEZIUS MUSCLE MUSCULUS LATISSIMUS DORSI AND ILEO COSTAL MUSCLE OF LOINS Work position Work position REV 03 09 03 ELECTRODE PLACEMENT MUSCULUS LATISSIMUS DORSI AND rn an En MUSCULUS ILEOCOSTAL THORACIS Work position Work position MUSCULUS RECTUS ABDOMINIS Work position BICEPS MUSCLE OF THIGH BICEPS FEMORIS SEMIMEMBRA NOUS AND SEMITENDINOUS MUSCLES TENSOR MUSCLE OF FASCIA LATA Work position REV 03 09 03 ELECTRODE PLACEMENT
20. m by pressing the OK key Depending on the model the display shows the following program sectors FITNESS amp SHAPE BEAUTY AESTHETIC PAIN ANTALGIC VASCULAR FACE LOWER NECK G PULSE microcurrent programs Step 1 Selection of Area Press the keys Up or Down on the Joy pad to move the highlight bar to the desired area Press OK to confirm Press the Left key Back for 3 sec in order to return to the previous display Step 2 Selection Man_Woman If the areas Fitness amp Shape is confirmed in STEP 1 the selection Man or Woman will appear If one of the other areas is confirmed in STEP 1 it will be possible to select a list of programmes Press the keys Up or Down on the Joy pad to move the highlight bar to the desired selection Press Press OK to confirm Press the Left key Back for three sec in order to return to the previous display Step 3 Selecting the programme name Press the keys Up or Down to select the name of the desired program Press OK to confirm Press the Left key Back for three sec in order to return to the previous display Step 4 Selecting the part of the body Programme start up Once you have selected the programme you can return to the previous display pressing down the key Left Back for 3 sec or you can start it increasing the intensity of the channel The intensity can be increased individually using the keys increase intensity of channels keys or simultaneously for the 4 chann
21. mulator should only be used by mentally competent adults Keep the instrument out of the reach of children The electrostimulator should not be used for purposes other than neuromuscular stimulation as described in this manual The electrostimulator must be used according to the instructions in this manual and under the continued supervision of a physician or a physical therapist Do not use the electrostimulator without first consulting your physician regarding any health problems The electrostimulator should only be used with the supplied skin electrodes intended for neu romuscular stimulation REV 03 09 03 Electronic monitoring equipment such as ECG monitors and alarms may not operate properly when electrostimulation is in progress Stimulation delivered by this device may be sufficient to cause electrocution Do not apply the current in trans thoracic modality because it may cause cardiac arrhyth mia Do not stimulate the pectoral and dorsal muscles simultaneously Do not use the electrostimulator near short wave therapeutic devices APPROPRIATE USES Read the operating manual carefully in order to avoid incorrect installation use or maintenan ce that can damage the apparatus the operator or the user The Globus Electrostimulator is designed to be used in the following settings Home Medical clinics Physiotherapy clinics Rehobilitation clinics and for the following purposes Pain treatment in general
22. ndorphinic Tens Pain relieving action Ideal for chronic On the affected Intensity Non thanks to the release pain area Cover the painful pins and of endorphins painful area with the needles sensation electrodes NOTES ON THE USE OF PROGRAMMES WITH MICRO CURRENTS This section refers to the use of the G PULSE programmes The programmes in the G Pulse area have a preset intensity uA Microcurrent programmes contain variations compared to normal TENS and EMS programmes as listed below Unlike normal electro stimulation treatments e g TENS that use milll Ampere Microcurrents use microampere currents that are undetectable for Man It is therefore normal to not notice any sensation except on the face which is an extremely sen sitive area The intensity of the current required to obtain a comfortable pins and needles sensation is totally personal It may depend on the placement of the electrodes on the adipose layer on perspiration on the presence of body hair on the area to be treated etc For these reasons the same intensity of current can provide different sensations from person to person from day to day from left side to right side During use of the G Pulse programmes on the face a slight stinging sensation must be felt if nothing is felt at the preset intensity increase the intensity using the increase keys or with the Up key When running a Microcurrents program use exclusively the special gray cables connecte
23. nfor mation consult the last pages of this operating manual Delete from list Eliminates a specific program from the Last 10 Executed list The Last 10 Executed list refers to a single user Besides the default user user 0 total of 9 different users can store program information in the Globus Electrostimulators memory To access a particu lar user s stored programs use the USER key see the USER SELECTION function in Setup menu 2 2 MODE SIMULTANEOUS STIMULATION The Globus Electrostimulator permits multiple treatments to be carried out at the same time In particular two different programs EMS or TENS can be run on different muscular groups of the same subject or on two different subjects The first program runs on channels 1 and 2 the second program runs on channels 3 and 4 To activate simultaneous stimulations use either 2 2 Mode menu or Program List from the main menu MULTIPLE PROGRAMS USING 2 2 Mode MENU From the main menu select 2 2 Mode and confirm with OK 1 Use the UP and DOWN keys to select the area of the first program channels land 2 and con firm with OK 2 Use the UP and DOWN keys to select Man or Woman for the first program 3 Use the UP and DOWN keys to choose the body part for treatment for the first selected pro gram 4 Use the UP and DOWN keys to select the specific program channels 1 and 2 and confirm with OK 5 Now select the program for channels 3 and 4 Use the UP and DOWN keys
24. ng lacta tion Until now no collateral effects regarding lactation have been observed Nonetheless during lactation it is recommended to not stimulate the thoracic region Are dermatological diseases e g psoriasis urticaria contraindications for electrostimulation Yes do not treat areas affected by dermatological diseases When are the first results of electrostimulation appa rent Aesthetic results of electrostimulation are always sub jective For Toning program with a regular program of 3 4 sessions per week a noticeable result may be observed after 15 days For Lipolysis and Drainage programs 40 days of treatment are necessary Results are obtained more quickly if treatments are combi ned with good physical activity and a correct life Style How many sessions can weekly perform For physical training consult the program of weekly training in the Globus Personal Trainer For fitness and aesthetics programs the number of sessions depends on the type of treatment 3 4 sessions per week on alternate days are suggested for toning daily treat ments are permitted for Lipolysis and Drainage pro grams 27 GLOBUS GLOBUS ITALIA SRL Via Vittorio Veneto 52 31013 TV Tel 0438 7933 Fax 0438 793363 www globusitalia com info globusitalia com
25. ogram Once a program has started it is possible to modify the duration frequency and amplitude of a program by pressing the FUNCTION key A new screen appears and the time of the program in progress starts blinking Use the UP and DOWN keys to modify the time The new time will automatically be confirmed after 5 seconds or by pressing the FN key Move to the other para meters that you want to modify by pressing the LEFT RIGHT keys and repeat the above men tioned process Skip a phase single program In order to pass to a successive phase before the end of the one in progress press the RIGHT key for 3 seconds To return to the previous phase press the BACK key for 3 seconds Increase or decrease intensity To change the intensity of a single channel use the corresponding INCREASE or DECREASE INTENSITY key To simultaneously increase or decrease the intensity of all channels use the UP or DOWN key SPECIAL FUNCTIONS AUTO STIM Automatic The AUTO STIM function enables the user to execute a program automatically i e without having to personally regulate the intensity Intensity values are automatically set to the levels used during the last execution of the same program In any moment the user can exit from the AUTO STIM mode by modifying the intensity Use the INCREASE or DECREASE INTENSITY keys The AUTO STIM function can be used only for programs listed among the Last 10 Executed list To access the AUTO STIM function choose Las
26. on to person from day to day and from the right side to the left side of the body During different sessions these phenomena make it necessary to regulate the intensity in order to obtain the same level of contraction The current intensities recommended in the different phases are proposed as indicative values and each person should modify these levels according to his personal needs Moderate intensity The muscle does not tire not even during prolonged treatments The con traction induced is tolerable and pleasant This is the first level on the graphic representation of intensity Intermediate intensity The muscle is visibly contracted but the stimulation does not cause the joints to move Elevated intensity The muscle is contracted substantially The muscular contraction will pro voke the extension or bending of the limbs if these are not blocked Maximum intensity The muscle is contracted maximally This is intense treatment that should be performed only only after having carried out various applications at lower intensity Moderate from 10 mA to 20 mA Intermediate 8 from 20 mA to 30 mA Elevated above 30 mA Maximum At the maximum level of tolerance but below the pain threshold In the descriptions of the various treatments the best levels of intensities are suggested NOTE The recommended levels of current are only indicative NOTE For Microcurrents programs it
27. r is not connected to the battery charger Starting up Connect the cables to the outlets on the main unit Connect the electrodes to the cables Place the electrodes on the skin of the body part to be treated Turn on the Electrostimulator by pressing the ON OFF OK button for 3 seconds a tone indica tes that the unit is on and the unit s name and software version appear on the lower left hand corner of the display After a few seconds the last executed program or default program appears on the display The unit is now ready for use If when you turn on the unit all the symbols appear on the display turn off the instrument and try again If this problem persists do not use the instrument and contact an authorized service center If the batteries are not sufficiently charged the instrument will switch off immediately Recharge the batteries following instructions in section Battery Charging Use the UP and DOWN keys of keyboard to chose your option on the main menu the Last 10 Executed programs the Program List Favorites Setup and XXXX By pressing the OK key after having selected Last 10 Executed the display shows the area the muscular group and the name of the last executed program If no program has been car ried out before the message EMPTY appears proceed to the Program List Program selection from the Program List menu Use the UP and DOWN keys to position the cursor on Program List and confir
28. t 10 Executed from the main menu and confirm by pressing OK Notes To execute a program in AUTO STIM mode it is necessary that the electrodes be applied in the position and muscular district or body part chosen for the previous execution of the same pro gram Intensity readings are specific to each channel When using AUTO STIM mode each user must access the electrostimulator with a personal user code USER key 12 REV 03 09 03 Last 10 Executed The Globus Electrostimulator memorizes the last 10 programs carried out so that these are avai lable for rapid and easy execution Registration in memory occurs automatically at the end of any program when the memory is full older programs are automatically deleted To recall a program in memory position the cursor on Last 10 Executed of the main menu and confirm by pressing OK If no programs are stored in memory the word EMPTY appears Use the UP and DOWN keys to select the desired program and confirm with OK Three options appear Start Permits the user to execute the program in manual or AUTO STIM mode To start the program in manual mode use the channel specific INCREASE and DECREASE ITENSITY keys Alternatively press OK to start the AUTO STIM mode The word AUTO appears on the display above the phase indicator exit from AUTO STIM mode by modulating the intensity of any chan nel Position electrodes Displays a brief guide for correct electrode positioning For further i