1. 18 3 OPERATING DETERMINATIONS 222 2220222 eege EEN 20 4 DISCRIPTION 4 4 422 2230420002 2a evucusuedvaauieucncadeudulemensaddeadeundsenvueuduenvenuaeeeubsadsvadiedenuvae 21 LXEITUN T v t M Pm 21 4 2 Operating elements and conpnechons nn 22 Nell Le 4 1 MOUNTING OM a stand EE Z2 EDIno TO THUS AE EE EET A A E E E A A E A E SER PEFEE ISSN 43 ies lols un CN EE e Er 5 MAKING TRIE CONNEC TIONS ee e 5 1 Connection with the Mains nennen 5 2 Connection to a DMX512 controller 5 3 Interconnecting several light sets master slave operation nenn emm emen 25 5 4 Connection to the foot pedal ER 25 6 OPERATION ee ee MM 26 6 1 Operation without external Control 5 coiere eek toan nena Een ara ea sts nina ras ve See LE Er ced vna gege 26 6 1 1 Sound Control IEEE 26 6 1 2 AULOMAlIC Mode EE 26 6 1 3 Master slave operation with several light seis 26 6 2 Remote control with the foot pedal ERT 27 6 3 Operation via DMX controller ooseeneeeeoeeeeseneeeeeersttenstesttttntrtetttttt ttnn tt ertt tE ESEESE EEEEES SEEE ERESSE EEEE EE ESEE EEEE Eese nnne Eee 27 6 3 1 Setting the DMX starting address and selecting the DMX operating mode 27 6 3 2 DMX Proto une aaa bends Peete eee bd E EE eed cede eee ea 28 6 3 3 Operation with the DMX LED Operator 3 29 7 CLEANING AND MAINTENANGE 22 4222u2254224242200 dine as a an needed 30
2. B DMX LED Operator 4 oder mit dem passenden Fu schalter FP 1 separat erh ltliches Zubeh r Dieses Produkt ist nur f r den Anschluss an 230 V 50 Hz Wechselspannung zugelassen und wurde ausschlie lich zur Verwendung in Innenr umen konzipiert Dieses Ger t ist f r professionelle Anwendungen z B auf B hnen in Diskotheken Theatern etc vorgesehen Lichteffekte sind nicht f r den Dauerbetrieb konzipiert Denken Sie daran dass konsequente Betriebspausen die Lebensdauer des Ger tes erh hen Vermeiden Sie Ersch tterungen und jegliche Gewaltanwendung bei der Installation oder Inbetriebnahme des Ger tes Achten Sie bei der Wahl des Installationsortes darauf dass das Ger t nicht zu gro er Hitze Feuchtigkeit und Staub ausgesetzt wird Vergewissern Sie sich dass keine Kabel frei herumliegen Sie gef hrden Ihre eigene und die Sicherheit Dritter Das Ger t darf nicht in einer Umgebung eingesetzt oder gelagert werden in der mit Spritzwasser Regen Feuchtigkeit oder Nebel zu rechnen ist Feuchtigkeit oder sehr hohe Luftfeuchtigkeit kann die Isolation reduzieren und zu t dlichen Stromschl gen f hren Beim Einsatz von Nebelger ten ist zu beachten dass das Ger t nie direkt dem Nebelstrahl ausgesetzt ist und mindestens 0 5 m von einem Nebelger t entfernt betrieben wird Der Raum darf nur so stark mit Nebel ges ttigt sein dass eine gute Sichtweite von mindestens 10 m besteht Die Umgebungstemperatur muss zwischen 5 C u
3. T WIREPIECING INS TUSE e M M 30 8 TECHNICAL SPECIFICATIONS erred orani enne tnra nni n nna in nnnm n Hanna En anne wav NEEN dx nm mr xin an damna 31 8 1 ACCESSOMES 31 Diese Bedienungsanleitung gilt f r die Artikelnummer This user manual is valid for the article number 42109780 Das neueste Update dieser Bedienungsanleitung finden Sie im Internet unter You can find the latest update of this user manual in the Internet under www eurolite de 3 31 00054241 DOC Version 2 0 Deutsch BEDIENUNGSANLEITUNG euro jle LED KLS 400 RGB DMX Kompakt Lichtset ACHTUNG Ger t vor Feuchtigkeit und N sse sch tzen Vor Offnen des Ger tes vom Netz trennen Alle Personen die mit der Aufstellung Inbetriebnahme Bedienung Wartung und Instandhaltung dieses Ger tes zu tun haben m ssen entsprechend qualifiziert sein diese Bedienungsanleitung genau beachten die Bedienungsanleitung als Teil des Produkts betrachten die Bedienungsanleitung w hrend der Lebensdauer des Produkts behalten die Bedienungsanleitung an jeden nachfolgenden Besitzer oder Benutzer des Produkts weitergeben sich die letzte Version der Anleitung im Internet herunter laden 1 EINF HRUNG Wir freuen uns dass Sie sich f r das EUROLITE Kompakt Lichtset LED KLS 400 RGB DMX entschieden haben Wenn S
4. There must never be any objects entering into the device This is especially valid for metal parts If any metal parts like staples or coarse metal chips enter into the device the device must be taken out of operation and disconnected immediately Malfunction or short circuits caused by metal parts may cause mortal injuries HEALTH HAZARD IN Never look directly into the light source as sensitive persons may suffer an epileptic shock especially meant for epileptics Keep away children and amateurs Never leave this device running unattended 19 31 00054241 DOC Version 2 0 3 OPERATING DETERMINATIONS The compact light set LED KLS 400 RGB DMX consists of four slimline LED spots and the control unit The set comes pre assembled in a pratical transport bag It can be placed on a lighting stand or mounted to a truss Thanks to the integrated control unit with LED display the light set can be used without external control in sound controlled mode or in automatic mode with processor controlled color changes Control is also possible via a DMX controller e g DMX LED Operator 4 or the matching foot pedal FP 1 available as accessory This device is a lighting effect for creating decorative effects This product is only allowed to be operated with an alternating voltage of 230 V 50 Hz and was designed for indoor use only This device is designed for professional use e g on stages in discotheques theatres etc Lighting effects a
5. Connector for the foot pedal FP 1 4 Fixation screw 5 LED display 6 Control buttons button MENU to call the menu items button DOWN to switch between sound control and automatic mode button UP to switch to DMX operation buttons UP and DOWN to set the speed in automatic mode and to set the DMX starting address 7 Jack DMX IN DMX signal input 3 pin XLR for connecting a controller 22 31 8 Jack DMX OUT DMX signal input 3 pin XLR for connection to the DMX input of another light effect unit 9 Power input with fuse holder Used to plug the supplied power cord in Only replace the fuse when the device is disconnected from mains Only use fuses of the same rating and power The correct value is specified on the device 10 LED spot 1 to 4 11 Connection cable for the control unit 12 TV pin for placing on a stand 13 Fixation screw 00054241 DOC Version 2 0 4 MOUNTING 4 1 Mounting on a stand For mobile use place the light set on a lighting stand Suitable items can be found in chapter Accessories 1 On the stand the fixation screws of the legs Pull out the legs until the cross struts stand at a 90 angle to the legs Tighten the fixation screws of the legs 2 Attach the light set via its TV pin on the control unit to the top end of the stand and fasten the fixation Screw 3 Caution The load has to be installed in a balanced way The carryi
6. Controllers amp pell Eu aa wu 8 Buchse DMX OUT DMX Signalausgang 3 pol XLR zum Anschluss an den DMX Eingang eines weiteren Lichteffektgerats 9 Netzanschluss mit Sicherungshalter Stecken Sie hier die Netzleitung ein Ersetzen Sie die Sicherung nur bei ausgestecktem Ger t und nur durch eine gleichwertige Sicherung Der korrekte Wert ist am Ger t angegeben 10 LED Scheinwerfer 1 bis 4 11 Anschlusskabel f r die Steuereinheit 12 TV Zapfen zum Aufsetzen auf ein Stativ 13 Feststellschraube 00054241 DOC Version 2 0 4 INSTALLATION 4 1 Montage auf einem Stativ F r den mobilen Einsatz setzen Sie das Lichtset auf ein Leuchten Stativ auf Passende Artikel finden Sie im Kapitel Zubeh r 1 L sen Sie zun chst am Stativ die Feststellschrauben der Stellf e Ziehen Sie die Stellf e aus bis die Querstreben in einem 90 Winkel zu den Stellf en stehen Ziehen Sie die Feststellschrauben der Stellf e fest 2 Setzen Sie das Lichtset ber seinen Stativzapfen an der Steuereinheit am oberen Stativende auf und ziehen Sie die Feststellschraube fest 3 Achtung Beim Aufbringen der Last ist eine gleichm ige Lastverteilung erforderlich Die Traglast des Stativs darf niemals berschritten werden Das Stativ muss standsicher aufgestellt werden Vergewissern Sie sich dass alle Feststellschrauben sicher sitzen 4 2 Befes
7. When the master unit is to be controlled with the foot pedal FP 1 also set each slave unit to the DMX starting address AGG D and then switch to the DMX operating mode The interconnected light sets can now be operated in sync with the foot pedal 26 31 00054241 DOC Version 2 0 6 2 Remote control with the foot pedal FP 1 The foot pedal available as accessory allows convenient control of the light set 1 Press pedal 1 PRESETS repeatedly for the desired function One in seven preset colors or color change and color fade of the colors can be selected Number Function white red green blue cyan yellow purple color change every second color fade every 3 seconds ool o0 O1 AIIN gt Press pedal 2 SOUND CONTROL to select sound control Press pedal 3 FREEZE to select the freeze function Then the current color is kept Press pedal 4 BLACK OUT to switch off all LEDs After switching the light set of and on again the function selected last is activated O9 RON 6 3 Operation via DMX controller For operation with a controller with DMX512 protocol the light set is equipped with 15 control channels 6 3 1 Setting the DMX starting address and selecting the DMX operating mode 1 To be able to operate the light set with a DMX controller the DMX starting address must be set for the first DMX channel For this press the button MENU so many ti
8. can be synchronized and controlled with the master unit 1 Connect the jack DMX OUT of the master unit via a 3 pin XLR cable to the jack DMX IN of the first slave unit 2 The connect the jack DMX OUT of the first slave unit to the jack DMX IN of the second slave unit etc unit all units have been connected in a chain 5 4 Connection to the foot pedal FP 1 Connect the connection plug of the foot pedal to the jack FOOTSWITCH on the control unit 25 31 00054241 DOC Version 2 0 6 OPERATION After connecting the unit to the mains it requires a short initialization process and is then ready for operation It may be controlled via DMX controller or a foot pedal Alternatively it can be operated without external control in sound controlled mode or in automatic mode with processor controlled color changes The operating modes can be selected by means of the display and the control buttons D H DMX start adress 5 ig End Sound control HI D Auto mode D g DMX control i 5 5i Speed in auto mode Inn tu Fig Menu structure 6 1 Operation without external control 6 1 1 Sound control 1 Via the microphone which is integrated in the control unit the rhythm of the music sufficient bass provided can be perfectly reproduced by the light set To select sound control press the button MENU so many times u
9. it on immediately The arising condensation water might damage your device Leave the device switched off until it has reached room temperature 18 31 00054241 DOC Version 2 0 Please make sure that there are no obvious transport damages Should you notice any damages on the A C connection cable or on the casing do not take the device into operation and immediately consult your local dealer This device falls under protection class The power plug must only be plugged into a protection class outlet The voltage and frequency must exactly be the same as stated on the device Wrong voltages or power outlets can lead to the destruction of the device and to mortal electrical shock Always plug in the power plug last The power plug must always be inserted without force Make sure that the plug is tightly connected with the outlet Never let the power cord come into contact with other cables Handle the power cord and all connections with the mains with particular caution Never touch them with wet hands as this could lead to mortal electrical shock Never modify bend strain mechanically put pressure on pull or heat up the power cord Never operate next to sources of heat or cold Disregard can lead to power cord damages fire or mortal electrical shock The cable insert or the female part in the device must never be strained There must always be sufficient cable to the device Otherwise the cable may be damaged which may lead to mort
10. sich dann ber einen DMX Controller oder den Fu schalter FP 1 bedienen Alternativ kann es auch ohne externe Steuerung im musikgesteuerten Modus oder im Automatikbetrieb mit prozessorgesteuerten Farbwechseln betrieben werden Mithilfe des Displays und der Bedientasten lassen sich die Betriebsarten einstellen D H i i DMX Startadresse 5 ig ofld Musiksteuerung Argo Automatikbetrieb 5 id DMX Steuerung i 5 51 Geschwindigkeit im Automatikbetrieb inn Lu Abb Men struktur 6 1 Betrieb ohne externe Steuerung 6 1 1 Musiksteuerung 1 Durch das in der Steuereinheit integrierte Mikrofon l sst sich der Rhythmus der Musik bei deutlichem Bassschlag optimal mit dem Lichtset wiedergeben Zum Anw hlen der Musiksteuerung dr cken Sie die Taste MENU so oft bis das Display 1571 anzeigt 2 Passen Sie mit dem Regler SENSITIVITY die Mikrofonempfindlichkeit an die Lautst rke der Musik an Wird die Lautst rke der Musik danach ge ndert muss die Mikrofonempfindlichkeit erneut entsprechend angepasst werden Bei zu geringer Lautst rke oder fehlendem Bassschlag leuchten die LEDs nicht 6 1 2 Automatikbetrieb 1 Zum Anw hlen des Automatikbetriebs mit prozessorgesteuerten Farbwechseln dr cken Sie die Taste MENU so oft bis das Display 5 d anzeigt 2 Dr cken Sie die Taste DOWN um in den Automatikbetrieb zu w
11. t ber das Netzkabel ans Netz an 230 V AC 50 Hz Die Belegung der Anschlussleitungen ist wie folgt Leitung Pin International Au enleiter Blau Neutralleiter Gelb Gr n Schutzleiter Hinweis Der Schutzleiter muss unbedingt angeschlossen werden Wenn das Ger t direkt an das rtliche Stromnetz angeschlossen wird muss eine Trennvorrichtung mit mindestens 3 mm Kontakt ffnung an jedem Pol in die festverlegte elektrische Installation eingebaut werden Das Ger t darf nur an eine Elektroinstallation angeschlossen werden die den VDE Bestimmungen DIN VDE 0100 entspricht Die Hausinstallation muss mit einem Fehlerstromschutzschalter RCD mit 30 mA Bemessungsdifferenzstrom ausgestattet sein Z Zum Ausschalten ziehen Sie den Netzstecker aus der Steckdose Schlie en Sie die Lichtanlage nicht ber einen Dimmer an die Netzspannung an F r besseren Bedienkomfort schlie en Sie die Lichtanlage an eine schaltbare Steckdose an 5 2 Anschluss an einen DMX512 Controller Die Verbindung zwischen Controller und Ger t sowie zwischen den einzelnen Ger ten muss mit einem zweipoligen geschirmten Kabel erfolgen Die Steckverbindung geht ber 3 polige XLR Stecker und Kupplungen Sollen DMX Controller mit anderen XLR Ausg ngen angeschlossen werden m ssen Adapter kabel verwendet werden Belegung der XLR Verbindung DMX Ausgang DMX Eingang XLR Einbaubuchse XLR Einbaustecker 1 Masse 1 Masse 2 Signal 2 Signal 3 Signa
12. 0000 0000000000000 Fea Va Een e Qo Fer aan nn ann a raa FT s Fu KEREN ka FP FEET E Ra Rud 12 mzidsctee 12 6 1 B tneb oh externe ZateenIng e 12 6 11 OI e Di E 12 6 1 2 Automatikbetrieb 2 2 cecececccececeauessececececeauessececceeeeauesseceaeceueaaseceeeeeseaueaseeeeeeeseauesseseseeeeeauenseeeeeceseaaeeeeeeseeaeags 12 6 1 3 Master Slave Betrieb mit mehreren Lichtseis 13 6 2 Fernbedienung mit dem Fu schalter ER 13 6 3 Betrieb ber einen DMX Controller ccccccccceseseecececcceaeeesecececeseeasececeeeceaueaseeecensaaueasececeeeseaueaseceeeeeaeaaeeeeeeseeaeans 13 6 3 1 DMX Startadresse einstellen und DMX Betriebsart anw hlen nnnsssssssnnnssnssssrrrnrresssrnrnrnurssrsrrrrresrsrnrisrssnsrnrnt 13 6 3 2 BIO siye deir 14 6 3 3 Betrieb mit dem DMX LED Operator A 15 Te REINIGUNG UND WARTUN GQG 4 5754555 223 52 e agna Co an SIRE F3 Lr gg cn Co an Dax E si Cu eR ca na an aou cd cama ond eaa aa cUa ara nada ga Rocco an ada ada a Sean ga drea eigo ran 16 LA SICHEMINGSWECMSEl EE 16 8 TECHNISCHE DATEN ncn in nnn a nn 1 o a ig n th 4 m Eed ER n du a ann io lo aan Rma ax un nn nh ag io noa aa asa mn ege EEN AN 17 E Ee EE 17 2 31 00054241 DOC Version 2 0 Table of contents INTRODUCTION erc 18 2 SAFETY INSTRUCTIONS
13. al damage Make sure that the power cord is never crimped or damaged by sharp edges Check the device and the power cord from time to time If extension cords are used make sure that the core diameter is sufficient for the required power consumption of the device All warnings concerning the power cords are also valid for possible extension cords Always disconnect from the mains when the device is not in use or before cleaning it Only handle the power cord by the plug Never pull out the plug by tugging the power cord Otherwise the cable or plug can be damaged leading to mortal electrical shock If the power plug or the power switch is not accessible the device must be disconnected via the mains If the power plug or the device is dusty the device must be taken out of operation disconnected and then be cleaned with a dry cloth Dust can reduce the insulation which may lead to mortal electrical shock More severe dirt in and at the device should only be removed by a specialist There must never enter any liquid into power outlets extension cords or any holes in the housing of the device If you suppose that also a minimal amount of liquid may have entered the device it must immediately be disconnected This is also valid if the device was exposed to high humidity Also if the device is still running the device must be checked by a specialist if the liquid has reduced any insulation Reduced insulation can cause mortal electrical shock
14. alter bequem bedienen 1 Dr cken Sie Fu pedal 1 PRESETS wiederholt f r die gew nschte Funktion Es k nnen eine der sieben voreingestellten Farben oder Farbwechsel bzw Farb berblenden der Farben ausgew hlt werden Anzahl Funktion Wei Rot Gr n Blau Cyan Gelb Violett Farbwechsel jede Sekunde Farb berblendung alle 3 Sekunden CO NN O O01 B do Pho Dr cken Sie Fu pedal 2 SOUND CONTROL zum Anwahlen der Musiksteuerung Dr cken Sie Fu pedal 3 FREEZE zum Anwahlen der Funktion Freeze Es wird dann die aktuelle Farbe gehalten Dr cken Sie Fu pedal 4 BLACK OUT zum Ausschalten der LEDs Nach dem Aus und Wiedereinschalten ist immer die zuletzt angew hlte Funktion aktiviert 6 3 Betrieb ber einen DMX Controller F r den Betrieb ber einen Controller mit DMX512 Protokoll verf gt das Lichtset ber 15 Steuerkan le 6 3 1 DMX Startadresse einstellen und DMX Betriebsart anw hlen 1 Um das Lichtset mit einem DMX Controller betreiben zu k nnen muss die DMX Startadresse f r den ersten DMX Kanal eingestellt sein Dr cken Sie dazu die Taste MENU so oft bis das Display AOG an zeigt und stellen Sie dann mit den Tasten UP und DOWN die Adresse ein Hinweis Die Startadresse ist abh ngig von Ihrem DMX Controller Lesen Sie hierzu dessen Bedienungsanleitung Zum Wechseln in die DMX Betriebsart dr cken Sie die Taste MENU so oft bis das Display 5 1 od
15. ance between light output and the illuminated surface must be more than 0 1 meters This device is only allowed for an installation via the mounting bracket In order to safeguard sufficient ventilation leave 50 cm of free space around the device The housing must never touch surrounding surfaces or objects Make sure that the area below the installation place is blocked when rigging derigging or servicing the fixture Always fix the fixture with an appropriate safety bond The maximum ambient temperature T 45 C must never be exceeded Operate the device only after having become familiarized with its functions Do not permit operation by persons not qualified for operating the device Most damages are the result of unprofessional operation Never use solvents or aggressive detergents in order to clean the device Rather use a soft and damp cloth 20 31 00054241 DOC Version 2 0 Please use the original packaging if the device is to be transported Make sure that you pack the device in the original state Please consider that unauthorized modifications on the device are forbidden due to safety reasons Never remove the serial barcode from the device as this would make the guarantee void If this device will be operated in any way different to the one described in this manual the product may suffer damages and the guarantee becomes void Furthermore any other operation may lead to dangers like short circuit burns electric shoc
16. at safety relating and machine technical installations are inspected by an expert after every four years in the course of an acceptance test The operator has to make sure that safety relating and machine technical installations are inspected by a skilled person once a year The following points have to be considered during the inspection 1 All screws used for installing the devices or parts of the device have to be tightly connected and must not be corroded 2 There must not be any deformations on housings fixations and installation spots ceiling suspension trussing 3 The electric power supply cables must not show any damages material fatigue e g porous cables or sediments Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed DANGER TO LIFE Disconnect from mains before starting maintenance operation We recommend a frequent cleaning of the device Please use a soft lint free and moistened cloth Never use alcohol or solvents There are no serviceable parts inside the device except for the fuse Maintenance and service operations are only to be carried out by authorized dealers 7 1 Replacing the fuse If the fine wire fuse of the device fuses only replace the fuse by a fuse of same type and rating Before replacing the fuse unplug mains lead Procedure Step 1 Open the fuse holder on the rear panel with a fitting scre
17. ct installations or insufficient safety precautions DANGER TO LIFE Please consider the DIN 15560 27and the respective national norms during the installation The installation must only be carried out by an authorized dealer 23 31 00054241 DOC Version 2 0 When rigging derigging or servicing the fixture staying in the area below the installation place on bridges under high working places and other endangered areas is forbidden The operator has to make sure that safety relating and machine technical installations are approved by an expert before taking into operation for the first time and after changes before taking into operation another time The operator has to make sure that safety relating and machine technical installations are approved by an expert after every four year in the course of an acceptance test The operator has to make sure that safety relating and machine technical installations are approved by a skilled person once a year Before lifting or lowering the telescopic tubes you must always block a safety area around the stand This safety area must have a diameter of 1 5 times the maximum height IMPORTANT Overhead rigging requires extensive experience including but not limited to calculating working load limits installation material being used and periodic safety inspection of all installation material and the loads If you lack these qualifications do not attempt the installation yourself but instead us
18. e a professional structural rigger Improper installation can result in bodily injury and or damage to property The installation must always be secured with an appropriate secondary safety element e g steel rope This secondary safety attachment must be constructed in a way that no part of the installation can fall down if the main attachment fails You must only use safety bonds complying with DIN 56927 quick links complying with DIN 56927 shackles complying with DIN EN 1677 1 and BGV C1 carbines The safety bonds quick links shackles and the carbines must be sufficiently dimensioned and used correctly in accordance with the latest industrial safety regulations e g BGV C1 BGI 810 3 DANGER TO LIFE Before taking into operation for the first time the installation has to be approved by an expert 5 MAKING THE CONNECTIONS 5 1 Connection with the mains 1 Connect the device to the mains with the power plug 230 V AC 50 Hz The occupation of the connection cables is as follows Cable Pin International Brown Live L Blue Neutral N Attention The earth has to be connected If the device will be directly connected with the local power supply network a disconnection switch with a minimum opening of 3 mm at every pole has to be included in the permanent electrical installation The device must only be connected with an electric installation carried out in compliance with the IEC standards The electric installation must be
19. eb mit prozessorgesteuertem Farbwechsel Master Slave Betrieb Musiksteuerung ber eingebautes Mikrofon mit Empfindlichkeitsregler Bequeme Steuerung auch m glich ber optionalen 4 fach Fu schalter FP 1 voreingestellte Programme Musiksteuerung Freeze Blackout DMX512 Steuerung ber jeden handels blichen DMX Controller m glich belegt 15 Kan le Optimiert f r die Steuerung mit dem optionalen Steuerpult DMX LED Operator 4 Per DMX kann jeder Spot einzeln angesteuert werden DMX Funktionen Dimmer Automatikbetrieb Musiksteuerung Strobe Effekt Adressierung und Einstellungen ber Steuereinheit mit 4 stelliger LED Anzeige Geeignet zur Montage auf einem Leuchten Stativ nicht inkl Schwarz lackierte Metallausf hrung Ideal f r Bands B hnen oder Alleinunterhalter Anschlussfertig mit Netzleitung und Schutzkontaktstecker 7 31 00054241 DOC Version 2 0 4 2 Bedienelemente und Anschl sse 1 Mikrofon zur Musiksteuerung 2 Empfindlichkeitsregler f r das Mikrofon 3 Anschluss f r den Fu schalter FP 1 4 Feststellschraube 5 LED Display 6 Bedientasten Taste MENU zum Aufrufen der Men punkte Taste DOWN zum Wechsel zwischen Musiksteuerung und Automatikbetrieb Taste UP zum Wechsel in den DMX Betrieb Tasten UP und DOWN zum Einstellen der Geschwindigkeit im Automatikbetrieb und der DMX Startadresse 7 Buchse DMX IN DMX Signaleingang 3 pol XLR zum Anschluss eines
20. echseln Das Display zeigt Ara 3 Dr cken Sie erneut die Taste MENU um den Men punkt Geschwindigkeit zu aktivieren Das Display zeigt den Vorgabewert IS 5 an Stellen Sie mit den Tasten UP und DOWN die Geschwindigkeit im Automatikbetrieb von hoch S 00 bis niedrig S 100 ein 12 31 00054241 DOC Version 2 0 6 1 3 Master Slave Betrieb mit mehreren Lichtsets 1 Sind mehrere Lichtsets zusammengeschaltet gt 5 3 lassen sich mit dem Hauptger t Master alle Nebenger te Slave synchron steuern W hlen Sie dazu am Hauptger t die gew nschte Betriebsart Musiksteuerung oder Automatikbetrieb und stellen Sie jedes der Nebenger te auf die gleiche DMX Startadresse ein AGG gt 6 3 1 Wechseln Sie abschlie end an allen Nebenger ten in die DMX Betriebsart Dr cken Sie dazu die Taste MENU so oft bis das Display fid oder Ara anzeigt Dr cken Sie die Taste UP Das Display zeigt 5 und die zusammengeschalteten Lichtsets arbeiten synchron Soll das Hauptger t mit dem Fu schalter FP 1 gesteuert werden stellen Sie ebenfalls jedes Nebenger t auf die DMX Startadresse DD i ein und wechseln dann in die DMX Betriebsart Die zusammenge schalteten Lichtsets k nnen nun synchron mit dem Fu schalter betrieben werden 6 2 Fernbedienung mit dem Fu schalter FP 1 Das Lichtset l sst sich mit dem als Zubeh r erh ltlichen Fu sch
21. eitungen verwendet muss sichergestellt werden dass der Adernquerschnitt f r die ben tigte Stromzufuhr des Ger tes zugelassen ist Alle Warnhinweise f r die Netzleitung gelten auch f r evtl Verl ngerungsleitungen Ger t bei Nichtbenutzung und vor jeder Reinigung vom Netz trennen Fassen Sie dazu den Netzstecker an der Grifflache an und ziehen Sie niemals an der Netzleitung Ansonsten kann das Kabel und der Stecker besch digt werden was zu t dlichen Stromschl gen f hren kann Sind Stecker oder Ger teschalter z B durch Einbau nicht erreichbar so muss netzseitig eine allpolige Abschaltung vorgenommen werden Wenn der Netzstecker oder das Ger t staubig ist dann muss es au er Betrieb genommen werden der Stromkreis muss allpolig unterbrochen werden und das Ger t mit einem trockenen Tuch gereinigt werden Staub kann die Isolation reduzieren was zu t dlichen Stromschl gen f hren kann St rkere Verschmut zungen im und am Ger t d rfen nur von einem Fachmann beseitigt werden Es d rfen unter keinen Umst nden Fl ssigkeiten aller Art in Steckdosen Steckverbindungen oder in irgendwelche Ger te ffnungen oder Ger teritzen eindringen Besteht der Verdacht dass auch nur minimale Fl ssigkeit in das Ger t eingedrungen sein k nnte muss das Ger t sofort allpolig vom Netz getrennt werden Dies gilt auch wenn das Ger t hoher Luftfeuchtigkeit ausgesetzt war Auch wenn das Ger t scheinbar noch funktioniert muss es von einen Fachma
22. en gepr ft werden Dabei muss unter anderem auf folgende Punkte besonders geachtet werden 1 Alle Schrauben mit denen das Ger t oder Ger teteile montiert sind m ssen fest sitzen und d rfen nicht korrodiert sein 2 An Geh use Befestigungen und Montageort Decke Abh ngung Traverse d rfen keine Verformungen sichtbar sein 3 Die elektrischen Anschlussleitungen d rfen keinerlei Besch digungen Materialalterung z B por se Leitungen oder Ablagerungen aufweisen Weitere auf den jeweiligen Einsatzort und die Nutzung abgestimmte Vorschriften werden vom sachkundigen Installateur beachtet und Sicherheitsm ngel behoben LEBENSGEFAHR Vor Wartungsarbeiten unbedingt allpolig vom Netz trennen Das Ger t sollte regelm ig von Verunreinigungen wie Staub usw gereinigt werden Verwenden Sie zur Reinigung ein fusselfreies angefeuchtetes Tuch Auf keinen Fall Alkohol oder irgendwelche L sungsmittel zur Reinigung verwenden Im Ger teinneren befinden sich au er der Sicherung keine zu wartenden Teile Wartungs und Service arbeiten sind ausschlie lich dem autorisierten Fachhandel vorbehalten 7 1 Sicherungswechsel Wenn die Feinsicherung des Ger tes defekt ist darf diese nur durch eine Sicherung gleichen Typs ersetzt werden Vor dem Sicherungswechsel ist das Ger t allpolig von der Netzspannung zu trennen Netzstecker ziehen Vorgehensweise Schritt 1 ffnen Sie den Sicherungshalter an der Ger ter ckseite mit eine
23. equipped with a Residual Current Device RCD with a maximum fault current of 30 mA 2 To switch off the unit disconnect the power plug 3 Do not connect the light set to the mains voltage via a dimmer For a more convenient operation connect the light set to a mains outlet which is switchable 24 31 00054241 DOC Version 2 0 5 2 Connection to a DMX512 controller To connect the controller with the fixture or one fixture with another only use a stereo shielded cable and 3 pin XLR plugs and connectors If you wish to connect DMX controllers with other XLR outputs you need to use adapter cables Occupation of the XLR connection DMX output DMX input XLR mounting socket XLR mounting plug 1 Ground 1 Ground 2 Signal 2 Signal 3 Signal 3 Signal 1 Connect the DMX output of the first fixture in the DMX chain with the DMX input of the next fixture Always connect one output with the input of the next fixture until all fixtures are connected 2 Atthe last fixture the DMX cable has to be terminated with a terminator For this solder a 120 resistor between Signal and Signal into a 3 pin XLR plug and plug it in the DMX output of the last fixture The wires must not come into contact with each other otherwise N the fixtures will not work at all or will not work properly 5 3 Interconnecting several light sets master slave operation Several light sets may be interconnected Then all slave units
24. er AFG anzeigt Dr cken Sie die Taste UP Das Display zeigt Sid und nach wenigen Sekunden kann das Lichtset mit dem DMX Controller betrieben werden 13 31 00054241 DOC Version 2 0 6 3 2 DMX Protokoll Kanal 1 Voreingestellte Programme Automatikbetrieb Musiksteuerung Kanal 2 Mastersteuerung DMX Wert 000 255 Dimmen von 0 100 Kanal 3 Strobesteuerung DMX Wert 000 009 010 255 Strobe langsam schnell Kanal 4 Spot 1 Helligkeit Rot oder Ablaufgeschwindigkeit DMX Wert 000 255 Dimmen von 0 100 Ist Kanal 1 auf einen DMX Wert zwischen 010 249 eingestellt d h auf ein voreingestelltes Programm oder Automatikbetrieb steuert Kanal 4 die Ablaufgeschwindigkeit DMX Wert 000 255 Ablaufgeschwindigkeit langsam schnell Kanal 5 Spot 1 Helligkeit Gr n oder berblendzeit DMX Wert 000 255 Dimmen von 0 100 Ist Kanal 1 auf einen DMX Wert zwischen 010 249 eingestellt d h auf ein voreingestelltes Programm oder Automatikbetrieb steuert Kanal 5 die berblendzeit DMX Wert 001 255 berblendzeit schnell gt langsam 14 31 00054241 DOC Version 2 0 Kanal 6 Spot 1 Helligkeit Blau DMX Wert 000 255 Funktion Dimmen von 0 100 Kanal 7 Spot 2 Helligkeit Rot DMX Wert 000 255 Funktion Dimmen von 0 100 Kanal 8 Spot 2 Helligkeit Gr n DMX Wert 000 255 Funktio
25. er Schutzklasse Der Netzstecker darf nur an eine Schutzkontakt Steckdose angeschlossen werden deren Spannung und Frequenz mit dem Typenschild des Ger tes genau bereinstimmt Ungeeignete Spannungen und ungeeignete Steckdosen k nnen zur Zerst rung des Ger tes und zu t dlichen Stromschl gen f hren Den Netzstecker immer als letztes einstecken Der Netzstecker muss dabei gewaltfrei eingesetzt werden Achten Sie auf einen festen Sitz des Netzsteckers Lassen Sie die Netzleitung nicht mit anderen Kabeln in Kontakt kommen Seien Sie vorsichtig beim Umgang mit Netzleitungen und anschl ssen Fassen Sie diese Teile nie mit feuchten H nden an Feuchte H nde k nnen t dliche Stromschl ge zu Folge haben Netzleitungen nicht ver ndern knicken mechanisch belasten durch Druck belasten ziehen erhitzen und nicht in die N he von Hitze oder K ltequellen bringen Bei Missachtung kann es zu Besch digungen der Netzleitung zu Brand oder zu t dlichen Stromschl gen kommen Die Kabeleinf hrung oder die Kupplung am Ger t d rfen nicht durch Zug belastet werden Es muss stets eine ausreichende Kabell nge zum Ger t hin vorhanden sein Andernfalls kann das Kabel besch digt werden was zu t dlichen Stromschl gen f hren kann Achten Sie darauf dass die Netzleitung nicht gequetscht oder durch scharfe Kanten besch digt werden kann berpr fen Sie das Ger t und die Netzleitung in regelm igen Abst nden auf Besch digungen Werden Verl ngerungsl
26. euro e BEDIENUNGSANLEITUNG USER MANUAL LED KLS 400 RGB DMX LIGHT SET Fur weiteren Gebrauch aufbewahren Copyright Keep this manual for future needs en Nachdruck verboten Reproduction prohibited Inhaltsverzeichnis AZEINF HRUNG eege EE Ee A 2 SICHERHEITSHINWEISE sacscciccececsceaccccisscecdincavdsdeccavatuacaaucslcaasavcacdavdunccvacaguaceacdeeudeacascaceacGevechasageadaanesebdaacedcaccandesatiaveds 4 3 BESTIMMUNGSGEM SSE VERWENDUNG EE 6 4 GER TEBESCHREIBUNG 41 ealUf 6S ieiuna pectori e Eesen E a PE De ubl RE EUREN FEN Diadsaubsdan 20 0s Fa oes E TUT Be fusus v ET pP Adve DERE FE FTeIDP TIS 4 2 Bedienelemente und Anschlisse strn 1rr1 keran rr 11r en eSEE EEEEEEAS EEEE EEEEES EEEE nE Enen Ennn Ennen 8 A INSTALLA TON ME 9 4 1 Montage auf einem Stativ EE 9 4 2 Bef stigung an einer be 9 4 3 Scheinwerfer umsetzen 9 4 4 Gicherbeitebimwese csse eene nRmnnnennnnn nnne nnns nn ann n nsn ess sa esi esee sana eise si sisse setis e ess nnne rennes 9 5 ANSCHL SSE HERSTELLEN EE 11 5 dAnschluss ars NEZ e e cane SEHE ee ee EDD DOS EIER EE LR PDA E E DAE E ULTE ELT 11 5 2 Anschluss an einen DMSbI2 Controller nennen nenne nennen nennen nensis innen nsns s nsn n nsns nennen 11 5 3 Zusammenschalten meherer Lichtsets MasteriGl ve Betrieb 12 5 4 Anschluss an den Fulsschalter FP 1 00 su4s00 000
27. geltenden Sicherheitsvorschriften bem hen und diese einhalten Der Hersteller haftet nicht f r Sch den die durch unsachgem e Installation und unzureichende Sicher heitsvorkehrungen verursacht werden 9 31 00054241 DOC Version 2 0 und DIN 15560 27 zu beachten Die Installation darf nur vom autorisierten Fachhan del ausgef hrt werden LEBENSGEFAHR N Bei der Installation sind insbesondere die Bestimmungen der BGV C1 vormals VBG 70 W hrend des Auf Um und Abbaus ist der unn tige Aufenthalt im Bereich von Bewegungsfl chen auf Beleuchterbr cken unter hochgelegenen Arbeitspl tzen sowie an sonstigen Gefahrbereichen verboten Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen vor der ersten Inbetriebnahme und nach wesentlichen nderungen vor der Wiederinbetriebnahme durch Sachverst ndige gepr ft werden Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen mindestens alle vier Jahre durch einen Sachverst ndigen im Umfang der Abnahmepr fung gepr ft werden Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen mindestens einmal j hrlich durch einen Sachkundigen gepr ft werden Vor dem Aus und Einfahren der Teleskoprohre muss immer ein Sicherheitsbereich um das Stativ herum abgesperrt werden Dieser Sicherheitsbereich muss einen Durchmesser haben der der 1 5 fachen max
28. ie nachfolgende Hinweise beachten sind wir sicher dass Sie lange Zeit Freude an Ihrem Kauf haben werden Nehmen Sie das Produkt aus der Verpackung 2 SICHERHEITSHINWEISE ACHTUNG Seien Sie besonders vorsichtig beim Umgang mit gef hrlicher Netzspannung Bei die ser Spannung k nnen Sie einen lebensgef hrlichen elektrischen Schlag erhalten Dieses Ger t hat das Werk in sicherheitstechnisch einwandfreiem Zustand verlassen Um diesen Zustand zu erhalten und einen gefahrlosen Betrieb sicherzustellen muss der Anwender die Sicherheitshinweise und die Warnvermerke unbedingt beachten die in dieser Bedienungsanleitung enthalten sind IE Unbedingt lesen Bei Sch den die durch Nichtbeachtung der Anleitung verursacht werden erlischt der Garantiean spruch F r daraus resultierende Folgesch den bernimmt der Hersteller keine Haftung Das Ger t darf nicht in Betrieb genommen werden nachdem es von einem kalten in einen warmen Raum gebracht wurde Das dabei entstehende Kondenswasser kann unter Umst nden Ihr Ger t zerst ren Lassen Sie das Ger t solange uneingeschaltet bis es Zimmertemperatur erreicht hat 4 31 00054241 DOC Version 2 0 Bitte berpr fen Sie vor der ersten Inbetriebnahme ob kein offensichtlicher Transportschaden vorliegt Sollten Sie Sch den an der Netzleitung oder am Geh use entdecken nehmen Sie das Ger t nicht in Betrieb und setzen sich bitte mit Ihrem Fachh ndler in Verbindung Der Aufbau entspricht d
29. imalen Auszugsh he entspricht WICHTIG berkopfmontage erfordert ein hohes Ma an Erfahrung Dies beinhaltet aber beschr nkt sich nicht allein auf Berechnungen zur Definition der Tragf higkeit verwendetes Installationsmaterial und regelm ige Sicherheitsinspektionen des verwendeten Materials und der Leuchten Versuchen Sie niemals die Installation selbst vorzunehmen wenn Sie nicht ber eine solche Qualifikation verf gen sondern beauftragen Sie einen professionellen Installateur Unsachgem e Installationen k nnen zu Verletzungen und oder zur Besch digung von Eigentum f hren Die Installation muss immer mit einem zweiten geeigneten Sicherungselement z B Stahlseil erfolgen Diese zweite Aufh ngung muss so beschaffen und angebracht sein dass im Fehlerfall der Hauptaufh ngung kein Teil der Installation herabfallen kann Es d rfen nur Sicherungsseile gem DIN 56927 Schnellverbindungsglieder gem DIN 56927 Sch kel gem DIN EN 1677 1 und BGV C1 Kettbiner eingesetzt werden Die Fangseile Schnellverbindungsglieder Sch kel und Kettbiner m ssen auf Grundlage der aktuellsten Arbeitsschutzbestimmungen z B BGV C1 BGI 810 3 ausreichend dimensioniert sein und korrekt angewendet werden LEBENSGEFAHR Vor der ersten Inbetriebnahme muss die Einrichtung durch einen Sachverst ndigen gepr ft werden 10 31 00054241 DOC Version 2 0 5 ANSCHL SSE HERSTELLEN 5 1 Anschluss ans Netz 1 Schlie en Sie das Ger
30. k crash etc 4 DISCRIPTION 4 1 Features DMX LED spotlight set mobile color creativity was never so easy Complete LED light set consisting of slimline 4 spots and a crossbar with integrated DMX control unit and stand adaptor Ultra light ideally suited for mobile use Comes pre assembled with pratical transport bag 180 x 10 mm LED per spot 60 x red 60 x green 60 x blue Movable and tiltable spotlights DMX controlled operation or stand alone operation with processor controlled color change Master Slave operation Sound control via built in microhone with sensitivity control Convenient control possible via optional 4 pedal foot pedal FP 1 preset sound control freeze blackout DMX512 control via regular DMX controller occupies 15 channels Optimized for control with the optional control panel DMX LED Operator 4 Via DMX each spot can be individually controlled DMX functions dimmer automatic mode music control strobe effect Addressing and setting via control panel with 4 digit LED display Suited for installation on a lighting stand not included Black lacquered metal version Ideal for bands stages or solo entertainers Ready for connection with power cord and safety plug 21 31 00054241 DOC Version 2 0 4 2 Operating elements and connections 1 Microphone for sound controlled operation 2 Sensitivity control for the microphone 3
31. l 3 Signal Schlie en Sie den DMX Ausgang des ersten Ger tes der Kette an den DMX Eingang des n chsten Ger tes an Verbinden Sie immer einen Ausgang mit dem Eingang des n chsten Ger tes bis alle Ger te angeschlossen sind Am letzten Ger t muss die DMX Leitung durch einen Abschlusswiderstand abgeschlossen werden Dazu wird ein 120 O Widerstand in einen XLR Stecker zwischen Signal und Signal eingel tet und in den DMX Ausgang am letzten Ger t gesteckt Stelle miteinander in Kontakt treten Die Ger te werden ansonsten nicht bzw nicht korrekt funktionieren Achten Sie darauf dass die Adern der Datenleitung an keiner 1 11 31 00054241 DOC Version 2 0 5 3 Zusammenschalten meherer Lichtsets Master Slave Betrieb Es lassen sich mehrere Lichtsets zusammenschalten Das Hauptger t Master kann dann alle Nebenger te Slave synchron steuern 1 Verbinden Sie den Anschluss DMX OUT des Hauptger ts ber ein 3 poliges XLR Kabel mit dem Anschluss DMX IN des ersten Nebenger ts 2 Verbinden Sie dann den Anschluss DMX OUT des ersten Nebenger ts mit dem Anschluss DMX IN des zweiten Nebenger ts usw bis alle Ger te in einer Kette angeschlossen sind 5 4 Anschluss an den Fu schalter FP 1 Verbinden Sie den Anschlussstecker des Fu schalters mit der Buchse FOOTSWITCH an der Steuereinheit 6 BEDIENUNG Nach dem Anschluss ans Netz ben tigt das Ger t eine kurze Einstellphase und ist danach betriebsbereit Es l sst
32. m passenden Schrauben dreher Schritt 2 Entfernen Sie die defekte Sicherung aus dem Sicherungshalter Schritt 3 Setzen Sie die neue Sicherung in den Sicherungshalter ein Schritt 4 Setzen Sie den Sicherungshalter wieder im Geh use ein Sollten einmal Ersatzteile ben tigt werden verwenden Sie bitte nur Originalersatzteile Wenn die Anschlussleitung dieses Ger tes besch digt wird muss sie durch eine besondere Anschluss leitung ersetzt werden die von Ihrem Fachh ndler erh ltlich ist Sollten Sie noch weitere Fragen haben steht Ihnen Ihr Fachh ndler jederzeit gerne zur Verf gung 16 31 00054241 DOC Version 2 0 8 TECHNISCHE DATEN Spannungsversorgung 230 V AC 50 Hz Maximale Umgebungstemperatur 7 Max Leuchtentemperatur im Beharrungszustand T Mindestabstand zu enflammbaren Oberfl chen Ma e LxBxH 8 1 Zubeh r EUROLITE FP 1 Fu schalter Best Nr 42109710 EUROLITE STV 40A Stativ Alu Best Nr 59007001 EUROLITE STV 40 WOT Stativ Alu ohne T bar Best Nr 59007002 EUROLITE STV 40S WOT Stativ o T bar Stahl Best Nr 59007004 EUROLITE DMX LED Operator 4 Best Nr 70064504 Bitte beachten Sie Technische nderungen ohne vorherige Ank ndigung und Irrtum vorbehalten eu ro e erman 17 31 00054241 DOC Version 2 0 LE USER MANUAL euro jle LED KLS 400 RGB DMX Compact Light Set CAUTION Keep this device away from rain and moisture Unplug mains lead before openi
33. mehr korrekt funktionieren ist das meist das Ergebnis von unsachgem er Bedienung Reinigen Sie das Ger t niemals mit L sungsmitteln oder scharfen Reinigungsmitteln sondern verwenden Sie ein weiches und angefeuchtetes Tuch 6 31 00054241 DOC Version 2 0 Soll das Ger t transportiert werden verwenden Sie bitte die Originalverpackung um Transportsch den zu vermeiden Achten Sie bitte unbedingt darauf dass das Ger t im Lieferzustand verpackt wird Beachten Sie bitte dass eigenm chtige Ver nderungen an dem Ger t aus Sicherheitsgr nden verboten sind Der Serienbarcode darf niemals vom Ger t entfernt werden da ansonsten der Garantieanspruch erlischt Wird das Ger t anders verwendet als in dieser Bedienungsanleitung beschrieben kann dies zu Sch den am Produkt f hren und der Garantieanspruch erlischt Au erdem ist jede andere Verwendung mit Gefahren wie z B Kurzschluss Brand elektrischem Schlag Abst rzen etc verbunden 4 GER TEBESCHREIBUNG 4 1 Features DMX LED Scheinwerferset mobile Farbgestaltung war nie so einfach Komplette Lichtanlage bestehend aus 4 superflachen LED Spots und einem Quertr ger mit integrierter DMX Steuereinheit und Stativadapter Absolutes Leichtgewicht bestens geeignet f r mobilen Einsatz Lieferung erfolgt vormontiert in praktischer Transporttasche 180 x 10 mm LED pro Spot 60 rote 60 gr ne 60 blaue Scheinwerfer schwenk und neigbar DMX gesteuerter Betrieb oder Standalone Betri
34. mes until AGG i is indicated in the display Then use the buttons UP and DOWN to set the address Note The starting address depends upon which DMX controller is being used Please refer to its user manual 2 To switch to the DMX operating mode press the button MENU so many times until the display indicates 5d or Af a Then press the button UP The display will indicate 5 2 and after a few seconds the light set can be operated with the DMX controller 27 31 00054241 DOC Version 2 0 6 3 2 DMX protocol Channel 1 Preset programs automatic mode sound control Channel 2 Master control DMX value 000 255 Function Dimming from 0 100 Channel 3 Strobe control DMX value 000 009 Off 010 255 Strobe slow fast Channel 4 Spot 1 Brightness red or running speed Function DMX value 000 255 Function Dimming from 0 100 If channel 1 is set to a DMX value between 010 249 i e a preset program or automatic mode is selected channel 4 controls the running speed DMX value 000 255 Function Running speed slow fast Channel 5 Spot 1 Brightness green or fade time DMX value 000 255 Function Dimming from 0 100 If channel 1 is set to a DMX value between 010 249 i e a preset program or automatic mode is selected channel 5 controls the fade time DMX value 000 255 Fade time fast slo
35. n Dimmen von 0 100 Kanal 9 Spot 2 Helligkeit Blau DMX Wert 000 255 Funktion Dimmen von 0 100 Kanal 10 Spot 3 Helligkeit Rot DMX Wert 000 255 Funktion Dimmen von 0 100 Kanal 11 Spot 3 Helligkeit Gr n DMX Wert Funktion 000 255 Dimmen von 0 100 Kanal 12 Spot 3 Helligkeit Blau DMX Wert 000 255 Funktion Dimmen von 0 100 Kanal 13 Spot 4 Helligkeit Rot DMX Wert 000 255 Funktion Dimmen von 0 100 Kanal 14 Spot 4 Helligkeit Gr n DMX Wert 000 255 Funktion Dimmen von 0 100 Kanal 15 Spot 4 Helligkeit Blau DMX Wert 000 255 Funktion Dimmen von 0 100 6 3 3 Betrieb mit dem DMX LED Operator 4 Das als Zubeh r erh ltliche Steuerpult DMX LED Operator 4 ist optimal auf das Lichtset abgestimmt Es verf gt ber vier Kan le mit denen sich die Spots des Lichtsets synchron steuern lassen Um das Lichtset mit dem DMX LED Operator 4 betreiben zu k nnen stellen Sie die DMX Startadresse 021 ein 15 31 00054241 DOC Version 2 0 7 REINIGUNG UND WARTUNG Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen mindestens alle vier Jahre durch einen Sachverst ndigen im Umfang der Abnahmepr fung gepr ft werden Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen mindestens einmal j hrlich durch einen Sachkundig
36. nd 45 C liegen Halten Sie das Ger t von direkter Sonneneinstrahlung auch beim Transport in geschlossenen W gen und Heizk rpern fern Die relative Luftfeuchte darf 50 bei einer Umgebungstemperatur von 45 C nicht berschreiten Dieses Ger t darf nur in einer H henlage zwischen 20 und 2000 m ber NN betrieben werden Verwenden Sie das Ger t nicht bei Gewitter berspannung k nnte das Ger t zerst ren Das Ger t bei Gewitter allpolig vom Netz trennen Netzstecker ziehen Das Bildzeichen Q mf bezeichnet den Mindestabstand zu beleuchteten Gegenst nden Der Abstand zwischen Lichtaustritt und der zu beleuchteten Fl che darf 0 1 Meter nicht unterschreiten Das Ger t darf nur ber den Montageb gel installiert werden Um eine gute Luftzirkulation zu gew hrleisten muss um das Ger t ein Freiraum von mindestens 50 cm eingehalten werden Das Geh use darf niemals umliegende Gegenst nde oder Fl chen ber hren Achten Sie bei der Montage beim Abbau und bei der Durchf hrung von Servicearbeiten darauf dass der Bereich unterhalb des Montageortes abgesperrt ist Der Projektor ist immer mit einem geeigneten Sicherheitsfangseil zu sichern Die maximale Umgebungstemperatur T 45 C darf niemals berschritten werden Nehmen Sie das Ger t erst in Betrieb nachdem Sie sich mit seinen Funktionen vertraut gemacht haben Lassen Sie das Ger t nicht von Personen bedienen die sich nicht mit dem Ger t auskennen Wenn Ger te nicht
37. ng capacity of the stand must never be exceeded The stand must be set up in a stable way Make sure all fixation screws fit tight 4 2 Fixing to a truss The light set can be fixed to a truss using two C hooks with M10 screw Ba ww 3 x 25 9 4 8 LU ll N 1 In each case put the head of an M10 screw to the upper side of the control unit and together with the C hooks screw them down at the extreme ends of the control unit if possible 2 Suspend the C hooks in the truss and tighten the fixation screws 3 Always install a safety bond Before rigging make sure that the installation area can hold a minimum point load of 10 times the device s weight 4 3 Rearranging the spots If required the spots can be rearranged to the upper side of the control unit For this loosen the fixations screws on the lower side so that the spots can be removed Then loosen the fixation screws on the upper side rearrange the spots and tighten all fixation screws 4 4 Safety instructions For overhead rigging in public or industrial areas a series of safety instructions have to be followed that this manual can only give in part The operator must therefore inform himself on the current safety instructions and consider them The manufacturer cannot be made liable for damages caused by incorre
38. ng the housing For your own safety please read this user manual carefully before you initially start up Every person involved with the installation operation and maintenance of this device has to be qualilfied follow the instructions of this manual consider this manual to be part of the total product keep this manual for the entire service life of the product pass this manual on to every further owner or user of the product download the latest version of the user manual from the Internet 1 INTRODUCTION Thank you for having chosen the EUROLITE compact light set LED KLS 400 RGB DMX If you follow the instructions given in this manual we are sure that you will enjoy this device for a long period of time Unpack your product 2 SAFETY INSTRUCTIONS CAUTION Be careful with your operations With a dangerous voltage you can suffer a dangerous electric shock when touching the wires This device has left our premises in absolutely perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual IE Important Damages caused by the disregard of this user manual are not subject to warranty The dealer will not accept liability for any resulting defects or problems If the device has been exposed to drastic temperature fluctuation e g after transportation do not switch
39. nn berpr ft werden ob durch den Fl ssig keitseintritt eventuell Isolationen beeintr chtigt wurden Reduzierte Isolationen k nnen t dliche Strom schl ge hervorrufen In das Ger t d rfen keine fremden Gegenst nde gelangen Dies gilt insbesondere f r Metallteile Sollten auch nur kleinste Metallteile wie Heft und B roklammern oder gr bere Metallsp ne in das Ger t gelangen so ist das Ger t sofort au er Betrieb zu nehmen und allpolig vom Netz zu trennen Durch Metallteile hervorgerufene Fehlfunktionen und Kurzschl sse k nnen t dliche Verletzungen zur Folge haben GESUNDHEITSRISIKO Blicken Sie niemals direkt in die Lichtquelle da bei empfindlichen Menschen u U epileptische Anf lle ausgel st werden k nnen gilt besonders f r Epileptiker Kinder und Laien vom Ger t fern halten Das Ger t darf niemals unbeaufsichtigt betrieben werden 5 31 00054241 DOC Version 2 0 3 BESTIMMUNGSGEMASSE VERWENDUNG Das Kompakt Lichtset LED KLS 400 RGB DMX besteht aus vier superflachen LED Scheinwerfern und der Steuereinheit Die Lieferung erfolgt vormontiert in einer praktischen Transporttasche Das Set kann auf ein Leuchten Stativ aufgesetzt oder an einer Traverse befestigt werden Dank der integrierten Steuereinheit mit LED Anzeige l sst sich das Lichtset allein im musikgesteuerten Modus oder im Automatikbetrieb mit prozessorgesteuerten Farbwechseln betreiben Die Steuerung kann aber auch ber einen DMX Controller erfolgen z
40. ntil 5g is indicated in the display Adjust the microphone sensitivity to the volume of the music with the control SENSIVITY If the volume of the music is changed afterwards the microphone sensitivity must be readjusted accordingly The LEDs do no light if the volume is too low or if there is no sufficient bass beat 6 1 2 Automatic mode 1 2 3 To select the automatic mode with processor controlled color changes press the button so many times until Sf is indicated in the display Press the button DOWN to switch to automatic mode The display indicates Ara Once again press the button MENU to activate menu item speed The display indicates the default value 5 5 i Use the buttons UP and DOWN to adjust the desired speed in automatic mode from high S 00 to low S 100 6 1 3 Master slave operation with several light sets 1 When several light sets are interconnected 5 3 the slave units can be synchronized and controlled with the master unit For this select the desired operating mode music control or automatic mode at the master unit and set each slave unit to the same DMX starting address RGB i gt 6 3 1 Finally switch each slave unit to the DMX operating mode For this press the button MENU so many times until the display indicates 5 d or R7 B Then press the button UP The display will indicate 5 i2 and the interconnected light sets will now operate in sync
41. re not designed for permanent operation Consistent operation breaks will ensure that the device will serve you for a long time without defects Do not shake the device Avoid brute force when installing or operating the device When choosing the installation spot please make sure that the device is not exposed to extreme heat moisture or dust There should not be any cables lying around You endanger your own and the safety of others This device must never be operated or stockpiled in sourroundings where splash water rain moisture or fog may harm the device Moisture or very high humidity can reduce the insulation and lead to mortal electrical shocks When using smoke machines make sure that the device is never exposed to the direct smoke jet and is installed in a distance of 0 5 meters between smoke machine and device The room must only be saturated with an amount of smoke that the visibility will always be more than 10 meters The ambient temperature must always be between 5 C and 45 C Keep away from direct insulation particularly in cars and heaters The relative humidity must not exceed 50 with an ambient temperature of 45 C This device must only be operated in an altitude between 20 and 2000 m over NN Never use the device during thunderstorms Over voltage could destroy the device Always disconnect the device during thunderstorms The symbol Q mE determines the minimum distance from lighted objects The minimum dist
42. tigung an einer Traverse Das Lichtset l sst sich mit zwei C Haken mit M10 Schraube an einer Traverse befestigen S S x I LU 2 ux gd D UV 1 Stecken Sie jeweils den Kopf einer M10 Schraube in die Oberseite der Steuereinheit und schrauben Sie diesen dann zusammen mit dem C Haken m glichst an den u eren Enden der Steuereinheit fest 2 H ngen Sie die C Haken in die Traverse ein und ziehen Sie die Feststellschrauben fest 3 Sichern Sie die Installation immer mit einem Sicherungsseil Vergewissern Sie sich vor der Montage dass die Montagefl che mindestens die 10 fache Punktbelastung des Eigengewichtes der Installation aushalten kann 4 3 Scheinwerfer umsetzen Bei Bedarf lassen sich die Scheinwerfer auf die Oberseite der Steuereinheit umsetzen L sen Sie dazu die Feststellschrauben an der Unterseite sodass die Scheinwerfer entfernt werden k nnen L sen Sie dann die Feststellschrauben an der Oberseite setzen Sie die Scheinwerfer um und ziehen Sie alle Feststellschrauben wieder an 4 4 Sicherheitshinweise Bei berkopfmontage in ffentlichen bzw gewerblichen Bereichen ist eine F lle von Vorschriften zu beachten die hier nur auszugsweise wiedergegeben werden k nnen Der Betreiber muss sich selbst ndig um die Beschaffung der
43. w 28 31 00054241 DOC Version 2 0 Channel 6 Spot 1 Brightness blue DMX value 000 255 Function Dimming from 0 100 Channel 7 Spot 2 Brightness red DMX value 000 255 Function Dimming from 0 100 Channel 8 Spot 2 Brightness green DMX value 000 255 Function Dimming from 0 100 Channel 9 Spot 2 Brightness blue DMX value 000 255 Function Dimming from 0 100 Channel 10 Spot 3 Brightness red DMX value 000 255 Function Dimming from 0 100 Channel 11 Spot 3 Brightness green DMX value Function 000 255 Dimming from 0 100 Channel 12 Spot 3 Brightness blue DMX value 000 255 Function Dimming from 0 100 Channel 13 Spot 4 Brightness red DMX value 000 255 Function Dimming from 0 100 Channel 14 Spot 4 Brightness green DMX value 000 255 Function Dimming from 0 100 Channel 15 Spot 4 Brightness blue DMX value 000 255 Function Dimming from 0 100 6 3 3 Operation with the DMX LED Operator 4 The control panel DMX LED Operator 4 available as accessory is optimally adapted to the light set It has four channels so that all spots of the light set can be controlled in sync To control the light set with the DMX LED Operator 4 adjust the DMX starting address 021 29 31 00054241 DOC Version 2 0 7 CLEANING AND MAINTENANCE The operator has to make sure th
44. wdriver Step 2 Remove the old fuse from the fuse holder Step 3 Install the new fuse in the fuse holder Step 4 Replace the fuse holder in the housing Should you need any spare parts please use genuine parts If the power supply cable of this device becomes damaged it has to be replaced by a special power supply cable available at your dealer Should you have further questions please contact your dealer 30 31 00054241 DOC Version 2 0 8 TECHNICAL SPECIFICATIONS Power supply 230 V AC 50 Hz Maximum ambient temperature T Maximum housing temperature T steady state Min distance from flammable surfaces Min distance to lighted object F 2 A 250V Dimensions LxWxH 1200 x 55 x 310 mm Weight 8 5 kg 8 1 Accessories EUROLITE FP 1 Foot pedal 42109710 EUROLITE STV 40A Lighting stand alu 59007001 EUROLITE STV 40 WOT Lighting st no T bar 59007002 EUROLITE STV 40S WOT Lighting st no T bar 59007004 EUROLITE DMX LED Operator 4 70064504 Please note Every information is subject to change without prior notice 19 11 2010 eu fO Germany 31 31 00054241 DOC Version 2 0