Home
        DUO2 User Manual
         Contents
1.  caused by  output short circuit is not covered by warranty    Never allow the charger case to contact an AC DC power  supply case while powered   Do not drop or cause other shock to the charger  nor subject  it to moisture  condensation or liquids   Do not attempt to charge battery packs made from different  types of cells  a mixture of old and new cells  or cells made  with chemistry not supported by the EOS 0615i DUO3  NEVER attempt to charge    non rechargeable    cells   Do not open the case of the charger under any  circumstances  Doing so will void the warranty   Keep the charger away from children or pets at all times   NEVER ATTEMPT TO CHARGE A SINGLE BATTERY  ACROSS BOTH PORTS   example  a    single unit    10S pack  DOING  SO WILL DAMAGE THE CHARGER  BATTERY  AND WILL VOID  YOUR WARRANTY     DUO3 is designed to charge single packs up to 6S max  For  flight packs larger than 6S  DUO3 supports SYNC MODE balance  charging of two SEPARATED packs  which after charge are  series wired to make the flight pack     so 2x2S 4S up to 2x6S 12S series flight packs are possible     PUT SAFETY AHEAD OF ALL OTHER CONSIDERATIONS   SEEK MEDICAL ATTENTION IN EVENT OF ANY INJURY     HYPERI ON ACCEPTS NO RESPONSI BILITY FOR DAMAGE OR I NJ URY    FOR INDOOR or other HIGH RISK CHARGING ACTIVITY    see right  gt        Specifications  amp  Features     180W Per Port for 360 Watts Max CHARGE Output    0 1A to 15 0A max CHARGE Current in 0 1A steps   subject to 180W port limit with 14 5V  D
2.  or power supply are much more common than defects in the charger  Chargers  returned by the user and later found not defective will only be returned to the user at the user   s expense and may incur a service  charge     Memory Positions for Charging  and Settings per Battery Type  Twenty MEMORY positions on Each Channel allow you to set and store parameters for CHARGING your packs  such as BATTERY  TYPE  NiMH  NiCd  LiPo  Lilon  LiFePO4   A123   Lead Acid   battery CAPACITY  Charge RATE  Cutoff Voltage  Temperature  etc     BATTERY CHARGING   Let   s try it once to learn it       Example  LiPo battery with balance connector  Follow the flow charts as you go      MODE  Before Charging Discharging is started  Scrolls between MENUS for MEMORY  Charging   USER SETUP  DATA VIEW      aaa BALANCER  MODE also selects SOLO and SYNC modes for charging packs greater than 6S  GS MODE  During Charging Discharging  Scrolls between VIEW MODES  MEMORY  DATA VIEW  And DATA   lt  QUICK VIEW screens   ngyn  gt  UP  DOWN  Scroll through the settings within Menus  Data Views  and Selects values for Settings   gt  ENTER  Selects any Setting to CHANGE   Charge START   Charge STOP  CH   not pictured left  Selects which screen you are reading  Port  1 or Port  2         PS Load  tontrot    R    U  Er    Attach the charger to an appropriate DC power supply  Connect the Output Cable 4mm bullet connectors to the Red     and  Black     CH 1 output port on left side of the charger  Connect your Battery 
3.  the free ends  with correct Red       Black     Polarity  If you make up additional output cables   note that MINIMUM inner cable diameter should be 2 5mm  14ga  and MAXIMUM cable length is 20cm  8        It is critically important that you use either a fully charged 12V 24V lead acid automobile battery  or better  deep cycle  marine battery    or a high quality AC DC power supply in the range of 12V to 28V DC output  with minimum current rating of  10A  When charging high voltage batteries at high current  charger output 360W  the AC DC Power Supply  PS  should be 15V  minimum with rating of 350W or more  to insure reliable performance  Note that PS load control features DO allow you to use  lower rated power supplies reliably  but that total charger output wattage will be limited accordingly   See details later in this  manual     If you have any trouble charging after confirming that input and output cables are properly connected and of the proper  materials  be sure to check the charger on an automotive battery  Many problems are associated with poor quality or  inadequate switching AC DC power supplies  Use PS Load control as needed to reduce load on your PS  or upgrade your PS    If  after carefully reading the following pages on usage  you have any difficulty using the charger please refer to the  troubleshooting guide and warranty terms at the end of these instructions  It is best to carefully check your charger before  making a return  as problems in setup  cabling 
4. C PS     50W Per Port DISCHARGE with 10A Max Current    STORE MODE allows fast and simple charge discharge  to  60  capacity for proper storage of Lithium  Batteries   longer battery life     Charges Discharges 1 to 6 cells Lithium Polymer  Batteries Per Port  3 7V cell nominal types     Charges Discharges 1 to 6 cells Lithium Ion Batteries  Per Port  3 6V cell nominal types     Charges Discharges 1 to 6 LiFePO4  A123  cells   3 3V cell nominal types     Charges Discharges Cycles 1 16 cell NiCd Ni MH in  three modes  Normal  Linear  and Automatic    Charges Discharges 1 12 cell Lead Acid Batteries  Pb   2V cell     Allows Lithium Type batteries to 50 000mAh and PB   lead acid  batteries to 100Ah capacity    Two built  in Hyperion LBA10 300 Balancers with 15A  max rating and 300mA max balance rate cell    12 bit Resolution Balance Circuits for max accuracy  TCS   Terminal Capacity Selection    Rich Data Displays during and after charging and  balancing    USB PC Port for Data Logging  Firmware upgrades  and  future PC Control Software System  Sept1 Nov1 2009     Temperature Sensor Ports  amp  Temp Stop settings     Wide Voltage Input Range 11v 28v for higher efficiency  when charging high voltage packs  and compatibility  with a wider selection of AC DC power supplies    Power Supply Amperage Control to allow reliable  charging with lower output power supplies    Power Supply Voltage Control  PS Load Control  works  in concert with Amperage control to insure the charger  does 
5. Hyperion EOS0615i DUOS3 Charger   User   s Manual    v3 2 Firmware version  Visit http   media hyperion hk dn eos for the newest manuals  firmware  and software                USB Cable also included but not pictured    Warnings     The EOS 0615i DUO3 is a carefully designed charger with many built   in safety features  such as reverse polarity protection  input voltage  error warning  and cell count mismatch warnings for lithium  chemistry batteries  HOWEVER  IT IS THE RESPONSIBILITY OF THE  USER TO INSURE THAT THE CHARGER IS CONFIGURED AND USED IN  A SAFE MANNER IN PROPER ENVIRONMENT     Always be sure that the charger is properly configured for  the correct battery type   Be sure that your lithium battery pack balance connector  matches the multi adapter type connected to the charger   SYNC MODE charging should start with packs at nearly equal  discharge states  see more details in text    Be sure that the batteries you charge are capable of  charging at the rate you select   Never charge batteries unattended   Charge only in a fire resistant environment  non flammable  surfaces such as on concrete or brick   Do not charge near easily flammable materials   Do not charge batteries inside a model   Charging outdoors is recommended whenever practical   Use only high quality gold 4mm bullet connectors for charge  output cable connection to the charger  See    setup     Properly insulate and regularly inspect all connectors to  eliminate the possibility of short circuit  Damage
6. ITY mAh Ah  Charged in    C    or Discharged out    D      INPUT VOLTAGE  Vi    PACK VOLTAGE  V   CHARGE CURRENT  A   CAPACITY     of the pack at current time          DATA VIEW  Press the MODE button until you reach the DATA VIEW screen   see chart  3  Data View Display   Use the UP or DOWN key to scroll through the various information presented       NPUT   Current input voltage from the power supply   OUTPUT   The output voltage of charger while charging  or pack voltage of the battery while connected but not charging   BAT  RES   The internal resistance  IR  of the battery pack in mQ     IR value appears some seconds after charge is started  and will become more accurate as charge progresses    TEMP and PEAK TEMP   Current Temp  and Peak Temp recorded during the charge  requires optional temp sensor    CHARGE TIME  CHARGE CURRENT   PEAK CHARGE VOLTAGE   see chart for other information screens available under Data View          BALANCER MODE  Lithium types only     Try it out with a LITHIUM battery pack which has the proper Balance Connector attached  Attach the charger to an appropriate  DC power supply  and connect your battery pack   s main and balance connectors to charger as previously described     Press the MODE button until you reach the BALANCER Mode screen      Press DOWN once to reach the SELECT VOLTAGE screen  This screen simply shows you a very accurate voltage for each cell in  the pack  in turn  You will see  1CL  at upper right  and a voltage displayed belo
7. Main Connector to the Mating Connector you have  previously soldered to the Output Cable set  Connect your Lithium Polymer battery Balance Connector to the EOS Balance  Multi Adapter  ALWAYS USE THE BALANCER s  WHEN CHARGING LITHIUM BASED PACKS FOR SAFETY      See end of these instructions for more information and balance multi adapters for various brand lithium packs      Note  Always connect the Output Cable set to charger first  then battery  After charging is finished  always disconnect the  Battery main wire connectors from Output Cable set first  then disconnect Output Cable set from charger     After the Welcome screen  the charger will start on CH 1 and display the most recently used memory position    see flowchart  2  MEMORY DISPLAY at this time     Press CH to select which charger or port screen you are reading     1 or 2    will be shown in the top  right hand corner  Pressing ENTER once will make the Memory Position start flashing  Flashing values can be changed with UP   DOWN keys   While Mem Position is flashing  Press DOWN to scroll through the ten available memory positions    Press ENTER again to confirm the memory position that you wish to use    From the memory screen  now press DOWN to get to BATT TYPE  press ENTER to start BATT TYPE flashing for selection   Press DOWN until you see your desired Battery Type  LiPo in this case   Press ENTER to confirm    Press DOWN again to select Pack Voltage which matches your battery    Note  the Charger shows both pac
8. V or higher  may be desired by racers looking for competitive advantage  and therefore  TVC has been  demanded as a feature by racers  However  it is the official position of Hyperion that Competition Sanctioning Bodies are  irresponsible in allowing over voltage charging via their rulebooks  and therefore that both users and their sanctioning bodies are  FULLY responsible for any Loss  Damage  or Injury that may occur due to over voltage charging of batteries  Let   s say it again   If you want to use Positive TVC settings  you may make that choice  But ONLY if you personally deem it desirable  AND you are  taking FULL RESPONSI BILITY for any and all results which may arise  We encourage you to petition your sanctioning body  to STOP allowing LIPO terminal voltages in excess of 4 200V  which are both potentially unsafe and without significant benefit   we believe     Lithium Care   To maximize your investment in Lithium Battery packs  do the following      ALWAYS Store your packs at  60  capacity  After a day of flying  use STORE Mode to achieve this  It is especially harmful  to store lithium packs fully charged  and should be avoided for more that a day or two at most      AVOID discharging cells beyond 90  of capacity  80  is even better   NEVER fully discharge lithium packs      STORE your packs in a cool  relatively dry location     Charging Lithium Polymer in Excess of 1C Rate  3 7v Nominal LiPo types     LIPO MAX C   Under USER SETUP menu you will find a setting to al
9. do I see    0    current flowing during charge at regular intervals  Is it a    Pulse    charger   No  the 0615i simply pauses charging at intervals in order to make extremely accurate readings of cell pack condition     Troubleshooting     1  Ensure that the battery you are trying to charge and the settings on the EOS 0615i DUO3 match  Battery type  such as  NiMH or LiPo   battery capacity  number of cells  charge voltage   and charge rate must all be correct      2  Check that the input cable and output cables    Have proper connectors and are in good condition  Are not frayed  worn  cut  or damaged   Are the proper gauge  output 2 5mm  14ga   Are proper length  lt   30cm  12     on output side     3  Attach the charger input connectors to a 12V automotive battery that is in good condition and fully charged  Wiggle the  terminal clips into the battery posts to insure that you have a good connection  Many charger problems are due to poor quality  or inadequate switching AC DC power supplies  so this test is necessary to eliminate those from the list of suspects      4  Try another battery for charging  If the RC battery is in poor condition  over discharged  or in some other way defective   the charger may correctly refuse to charge it based on safety algorithms      5  Try another RC battery type  For example switch to a NiMH battery if you are failing to charge Lithium types  Success with  one type but failure with another generally indicates that the charger is working pr
10. er  documentation for other LiFePO4 types     NiCd and NiMH  Set BATT TYPE from MEMORY MODE screen as we did before in the LiPo example  Consult the battery  manufacturer   s documentation to determine the proper settings for VOLTAGE  CAPACITY  and CHG CURRENT     In addition to the charge settings we have already seen in LiPo Mode  three additional settings exist for NiCd and NiMH battery  types  These are essentially    expert    settings  and should be left at defaults unless you know why you want to change them   PEAK SENS  peak sensitivity   delta V    default for NiCd is 7mV C and NiMH is 5mV C   TRICKLE   sets a low current at which the charger will continue to charge the pack AFTER normal charge is ended   PEAK DELAY   Short interval after peak is detected during which the charger will continue to charge before terminating    STARTING CHARGE   SELECTING CHARGE TYPE  After setting MEMORY MODE charge parameters  holding down ENTER  takes you to a Sub Menu with three options for NiCd NiMH charge type  Press ENTER once to start the current setting flashing   and use DOWN key to scroll through the three choices  Hold down the START button after your selection to start charging     AUTOMATIC   Essentially ignores your setting for CURRENT  but charges at rate determined by the internal resistance of the  battery pack  Especially useful when you don   t know what settings you should make due to lack of documentation    LINEAR   Charges at whatever rate you have selected from 
11. ery to something less than full capacity      The first is for long term storage  Lithium batteries are best stored after charging to 50  60  of nominal capacity  However   rather than using TCS for this goal  it is easier and better to always use the STORE MODE function  STORE MODE automatically  charges or discharges as needed to reach 60  TCS  then stops      The second aim is to get more flight time in during a typical day at the field  by stopping the charge when the battery is 90   to 95  full  for example  Due to the CC CV method by which LiPo are charged  charging the last few mAh back into the pack  takes a LOT more time than the first few mAh did    So if you want to get in the air ASAP  and don   t mind a shorter flight then set  TCS at 90  95  could save you a good bit of charge time  In this case we suggest END ACTION setting of CONTINUE  that  way the charger will sound 10 beeps when TCS is reached  so you can stop charging and fly  If you don   t catch the warning  the  charger will continue to charge to full capacity  as a safety measure in case you have forgotten that TCS is set below 100       The third possibility is that evidence suggests that charging to 90  95  can increase battery cycle life  compared to 100   charges  So in this case set TCS ACTION to STOP     TVC Function  Terminal Voltage Control per each memory slot  LIPO and LIFE A123    The TVC function allows adjustment of final CHARGE voltage for LIPO and LIFE battery types for each memory posit
12. found at the battery  This could cause an over   voltage charge  If you find terminal voltage over 4 2V cell for any LIPO cell  reduce TVC setting on each memory position until  your MEASURED max cell voltage  at battery  is at 4 2V or lower if LIPO  or 3 6V or lower if LIFE      5mV to  80mvV  Ability to set terminal voltage above defaults is only at the request of competition car  boat  and aircraft  users  and only if the race sanctioning body allows terminal voltage for Lipo above 4 2V  or LIFE A123  above 3 6V    No LIPO battery maker or seller recommends or allows Terminal Voltage to be set higher than 4 200V  to our knowledge   Hyperion does not recommend or allow G3 Lipo Terminal Voltage to be set higher than 4 200V  Therefore any   setting above  OmV VOIDS your WARRANTY for your LIPO battery pack  Whenever ALL cells in a pack exhibit puffing  over voltage charging is  indicated and warranty will not be honored     WARNING  By setting the TVC to any POSITIVE SETTING above OmV  you ACCEPT ALL RESPONSIBILITY for Damage to your  battery  Fire  Injury  and any other Loss which may result  If you do not agree to accept all risk  DO NOT OPERATE YOUR  CHARGER UNLESS ALL MEMORY POSITIONS ARE SET TO DEFAULT OmV TVC position  Furthermore  it is your  responsibility to insure that no other person uses your charger if TVC is set to greater than  OmV  and to reset ALL memory  positions to TVC OmV default before selling your charger or giving it to others     Positive settings   5m
13. he time for about 30  longer than it should take your pack to charge    Keep in mind that a badly balanced pack may take longer than normal to charge  so don   t set this too tight  A Lipo pack at 1C  rate might take as much as 120 minutes to charge  so timer of about 160 180 minutes may be appropriate  Note that while    2    other safety checks based on capacity and voltage are also working for you  charging should never be left unattended in any  case     Press DOWN to TCS CAPACITY   For LiPo and Lilon battery types Terminal Capacity Selection is available from 50  to 100  of  pack capacity  During the charge  the EOS 0615i DUO3 will continually estimate capacity in the pack  and either terminate the  charge or sound a signal tone  and continue charging  when your selected TCS percentage is reached  depending on the value  for you set for TCS END ACTION  See end of manual for more details on TCS     Press DOWN to TCS END ACTION   Values are CONTINUE and STOP  CONTINUE is the default  In this case  when TCS  is  reached for settings 50  to 95   the charger will    beep    10 times  but continue charging to 100  until stopped  If TCS  ACTION is set to STOP  the charger will stop charging at that TCS setting and   if balancing is complete   then give COMPLETE   END  Buzzer according to you buzzer settings   or continue till balanced  then give End buzzer      Press DOWN to TVC   YOUR RISK  NEVER change this from default OmV setting  unless you have CAREFULLY read and  underst
14. hen max current would be  180W 10V 18A  BUT current is limited to 15A   so the max you get will be 15A  since the current limit is reached before wattage limit     NOTE ALSO  Lithium batteries use CC CV charge curves  so current will always fall as the battery becomes more charged       Why does the charger not give the END buzzer  or FLAT CHECK error   even though the pack has been attached for a  long time   I have checked and buzzer is set ON      LIPO LiFePO4  Most likely  you have set a charge rate lower than 1C  and the charger cannot terminate CC CV as required  current at that point is too low  Assuming your battery is of decent quality and condition  if not  do NOT charge it   there is NO  reason to charge at rates below 1C  Charge again at 1C and observe results  Note also that END buzzer will NOT sound until the  charger achieves target cell balance  For badly out of balance packs or large capacity packs  this could take up to an hour      NiCd NiMH  Same answer as Lipo LifePO4 above  for a different reason   Try charging at a higher rate  We have found that  many NiMH packs on the market today are poorly made  and do not signal delta v  indicating end charge  properly when  charged at low rates  and sometimes even at higher rates  Try setting delta v in your charger menu to a lower value  Try  charging at a higher rate  check battery for over temp    If nothing works  get a pack of cells from a known quality brand  Sanyo   GP  etc  and test your charger       Why 
15. ion    0mV  default  therefore no change  Lipo 4 200V terminal  LIFE A123  3 600V terminal     5mV to  80mV  5mV steps  so LIPO for example terminates at 4 205V 4 280V     5mV to  20mV  5mV steps  so LIPO for example terminates at 4 195V 4 180V     The TVC Function is found in every memory slot for Lipo and Life  below TCS ACTION setting screen  Note that the TCV settings  are RETAINED  like other Memory settings  when the charger is powered off  Be SURE that this setting is correct before using  any LIPO or LIFE memory slot  Default TVC 0mV strongly recommended      Note  After confirming CELL COUNT and START for LIPO LIFE charging  if TVC setting is not default  current TVC setting will be  shown for a few seconds before the charger begins the charge  Be sure to note the displayed TVC setting at this time  and STOP  the charge to reset TVC to default whenever so desired     Uses for TVC FUNCTI ON     5mV to  20mV  Reducing Terminal Voltage should only be done in case MEASURED cell voltage at your battery pack  with  quality digital voltmeter  shows Terminal voltage exceeding 4 2V for Lipo  or default 3 6V for LIFE A123 types   This essentially  acts as a calibration function  and should normally be unneeded when using EOS standard  supplied output leads and balance  harnesses  However  if you have made your own longer harnesses  the additional length in leads creates the possibility of extra  induced resistance  and therefore a reading at the charger lower than is actually 
16. is set  to anything other than the default OmV  the TVC setting will show on the screen for a few seconds before charging begins  IF  the TVC setting is NOT as you wish  default STRONGLY SUGGESTED   STOP and reset TVC  then begin charge again     see pages 5 amp 6 for full details on TVC function     Note  If the Lithium based pack is NOT connected to the balancer port  the Charger will read NO BALANCER  We strongly  recommend using the balancer at ALL times     Holding down ENTER  2 seconds  at any time while charging a battery will then STOP charging  or discharging  etc         MODE SELECTIONS    Before Charging Discharging Store are in progress  Pressing the MODE button will scroll you through the MEMORY  DATA VIEW   BALANCER and USER SETUP screens  allowing you to change parameters as you like  see charts for each     During Charging Discharging Store   Pressing the MODE button will scroll you through the MEMORY  BALANCER and QUICK  VIEW Data screens   see chart  9  OPERATION and FINISH DISPLAY       MEMORY   Short press UP DOWN buttons to scroll through the data presented  At the top memory screen  showing C  A    you can press ENTER and UP DOWN to change charge current if desired  You can also LONG press  2 seconds  UP button to  see each screen presented in turn at two second intervals       BALANCER   UP DOWN buttons to see detailed information on cell balancing  and individual cell voltages      QUICK VIEW   Shows the following useful info on a single screen   CAPAC
17. k voltage and the number of cells in Series  S  on this screen  matching the Voltage and  Battery Type you have selected  If the    S    and the Voltage don   t match your battery  you have the Wrong Battery Type  selected  like confusing Lilon 3 6v with LiPo 3 7v types   Use UP key to reach BATT TYPE again  and reset BATT TYPE properly     Press DOWN to get to BATT CAPACITY  press ENTER to make the mAh value flash and adjust with the UP or DOWN buttons  until it matches your battery  by increments of 100mAh  to max of 50 000mAh   Press ENTER to confirm    If your battery is 730mAh  for example  you could set this to 700mAh  The common CHARGE RATE  set in next screen  for  lithium is 1C of capacity  equal to 0 7A for a 700mAh setting      Press DOWN to get to CHG CURRENT  Max allowed charge rate for Lithium Polymer  LiPo 3 7v cell  is 2C default  but selectable  in USER SETUP  LIPO MAX C setting  1C 5C   CAUTION  For other cell types  there is no restriction  up to the 15A limit of the  charger  so BE SURE you know what CHG CURRENT setting to use for your battery  see also below text on cell types      Press DOWN to TEMPERATURE CUT OFF  Requires option part  HP EOSTMPSEN or  HP EOS1210I SEN  temp sensor  This is  most often used by advanced users for NiMH charging  The Default setting is 50 degrees Celsius     Press DOWN to SAFETY TIMER   Adjustable between 20 and 300 minutes  An alarm will sound during charging after selected  time interval during charging has elapsed  Set t
18. low setting of Maximum    C    charge rate for Lithium  Polymer  3 7v cell type  batteries  with options of 1C to 5C  2C is Default   Note that MAX C attainable will depend on the  Amps Max and Watt Max rating of your charger  and pack capacity     NOTE  It is entirely YOUR responsibility to determine the SAFE Max C for your LiPo pack    HYPERION original LCL  LCX  LVX  LVZ types  2C max charge rate    HYPERION GENERATION 3 25C  35C packs  5C max charge rate   HYPERION GENERATIONS 5C Rx packs  4C max charge rate  except 20C  Rx packs    5C max charge     HYPERION SWIFT CAR PACKS   5C max charge rate   ALL Swift Car packs ever produced support 5C rate  regardless of 2C charge cautions appearing on first production packaging     If using other than Hyperion lithium packs  consult your battery   s documentation for allowed C rates  before exceeding 1C charge  rate  If you don   t know the allowed max CHARGE rate for your pack  never exceed 1C rates     NET  DUO FAQ      The discharge function is supposed to be 10A Max  but when I discharged my pack I got less current  Why   Both charge and discharge functions are limited by both watts and amperage  whichever comes first   Charge  180W and 15A maxes per port  Discharge  50W and 10A maxes per port    If you are discharging a pack which starts at 10V  for example  the initial max current A  would be  50W 10V 5A   note that as the battery voltage drops during discharge  current will rise     If charging a pack which starts at 10V  t
19. max watts INPUT  primary for variable voltage PS units only      POWER SUPPLY CURRENT screen   Set at the rated CURRENT  A  of your power source  set to 40A if car battery      POWER SHARING screen   Set the shared power percentage for the two battery outputs  details below     Power Supply Voltage and Current together comprise PS Load Control  The EOS0615iDUO3 is an extremely powerful charger   and can   particularly when charging high voltage packs at high rate settings   pull more amperage than many power supplies  can deliver  To avoid stressing your PS and having charges terminated prematurely  you can tell the charger the rating of your  supply  to limit the load on the supply  If you find the PS is still overloaded  reduce the setting for POWER SUPPLY CURRENT until  the problem goes away  or buy a stronger Power Supply unit        You have a fixed Voltage AC DC PS with 20A rating  Set PS CURRENT to 20A  or less       You have an AC DC PS with variable voltage from 12V 18V  and 300W limit  Set your PS to 18V  set PS VOLTAGE to 18  set  PS CURRENT to 300W 18   16A  or less      BATTERY CHARGING   EXTENDED DETAIL    Consult the documentation or labels provided with your battery to determine the correct capacity setting  It is very important to  get this right  as the charger uses the capacity setting to determine nominal charge rate  amperage   TCS percentage  and  safety termination  Incorrect settings could damage the battery  and could even cause an accident     TRDE F
20. not overload your variable power supply    Adjustable Power Sharing   between Outputs   Input Cable with 4mm Male Connectors   Clamps  Output Cable Set Included  with 4mm Connectors  Two  Integral  Thermostat Controlled Cooling Fans    2 Line  16 Character  Yellow Backlit LCD Data Display   Highly visible in all conditions    20 User definable Memory Positions per port  40 total       Temp sensors available separate   HP EOSTMPSEN or EOS1210i SEN     Firmware upgrades only available if when improvements are identified in future     HIGH RISK CHARGING ADVI SORY   Avoid charging batteries indoors  If you must charge indoors   or any  place injury to persons or damage to property could occur in the event  of fire     then be sure to      Keep battery well away from flammables  2 meters or more      Contain battery in a heavy fireproof container  such as a brick box     Always monitor the charge          GENERAL SETUP and NOTES    The EOS0615iDUO3 comes with male 4mm Bullet connectors  aka    banana plugs     attached to the power INPUT cables   These cables are appropriate for attaching directly to most high quality AC DC power supply units  such as the BK Precision   USA  model 1692 15V  40A  600W   Also included are large Terminal Clips with matching 4mm female bullet connectors  for  attaching directly to 12V 24V lead acid batteries    Output side 4mm Male Connector   Cable assemblies   HP EOSOUTCORD x2  are also supplied  Carefully solder your  preferred battery connector to
21. ood the information on TVC function given on pages 5 amp 6  AND FULLY ACCEPT ANY CONSEQUENCES AND ALL RISKS     Press DOWN to DSCH CURRENT   If you ll be discharging  you ll set the discharge current here  Note that depending on the voltage of the  pack  the current you set may not be obtainable if the total Volts multiplied by Current  A  exceeds 50W     Press DOWN to DSCH VOLTAGE per cell   Lithium types should only be discharged for storage  so we recommend that you use STORE  MODE for that  Otherwise  you need to be sure of the V cell setting yourself  according to your battery type  Over discharge can damage packs     Pressing DOWN for a last time returns you to the    Memory Select    screen     At this point  see flowchart  7  Lilo   LiPo   A123 BATTERY START  Holding the ENTER key pressed down for two seconds  or more will start the CHARGE  STORE  or DISCHARGE process  select with UP DOWN Keys  for LiPo  Lilon  and A123 types  no  matter where in the MEMORY  CHARGE  screens you may be  Additionally  if balancer circuit is connected   SYNC MODE is  available via ENTER  short push  and UP DOWN arrow keys     With    CHARGE START SOLO MODE    selected  hold down ENTER for 2 seconds  Hold down ENTER again  the charger will then  read   BATTERY CHECK   and then ask you to confirm the number of cells in your battery pack  Press ENTER  short press  for  a final time to start charging   if balancer is connected  a 10 second countdown occurs  then auto start   If TVC Function 
22. operly  The failing battery type is almost  certainly in poor condition  wired incorrectly  or the charger may be improperly set      6  Contact your dealer with full details and description of the problem  including the type of input power source  RC battery type  and cell count  and history of the charger   that is  has the charger been working properly before  or failed from new condition      7  I have an OUTPUT CIRCUIT ERROR     Be sure that your pack balance connector type  polarity  and wiring system matches the multi adapter attached to the charger      Carefully inspect pack connector  balance wire harness and Multi Adapter for damage  wear  etc  If OK  then      Spray all connectors  including the one in charger  with de oxide contact spray  then insert remove connectors several times   then spray one last time and re connect      Use a solid DC PS or fully charged CAR battery for Input power  poor power supplies cause MANY problems         Test charger using a lithium battery known to be in good condition      Try a different brand battery  preferably with different balance connector and multi adapter type     8  My LCD does not light  or lights but no characters are visible   In most cases this happens when a charger has been dropped  or suffered some heavy vibration  The ribbon cable between LCD  unit and charger can become loose  Have your dealer open the charger and re seat the ribbon cable     Enjoy the Power     The Hyperion Team    WARRANTY   HYPERION Charge
23. or Lithium types CAPACITY is selected in mAh  Selection is in increments of 100mAh  CURRENT is set in Ampere  at  CHG CURRENT screen   so divide mAh by 1000 to get Amperage  For 700mAh  current is 0 7A for 1C  up to 1 4A for 2C etc  For  an 1800mAh pack then  1 8A for 1C  and 3 6A for 2C and so on     Sra Lithium Polymer  3 7v  vs  Lithium lon  3 6v  Please make absolutely sure that you properly identify the type of  lithium battery you are charging  the capacity in mAh  and the number of cells wired in series and the pack voltage  Lithium Ion   3 6v nominal  should never exceed 1C charge rate  Never charge Li lon 3 6V types by LIPO 3 7V charger mode           A123   LiFePO4 Cells  The A123 LiFePO4 charge discharge modes are intended for cells with 3 3V nominal produced by  A123 Company  Hyperion  or other brand LiFePO4 cells which are recognized to be of good quality from well known makers  In  MEMORY MODE  choose A123 for BATT TYPE  for charging such cells  The A123 charge mode MAY work with    no name brand     LiFePO4 cells having 3 3V nominal voltage  but Hyperion has found some    knock off    cells in the market of very questionable  quality  Customers who use A123 mode  LiFePO4 mode  to charge such off brand cells assume all risk     LiFePO4  a123  CHG CURRENT  A  setting  The EOS 0615iDUO3 does NOT limit max charge rate for LiFePO4 based on  capacity  It is our position that  4C rate is the target MAX for Hyperion or A123 LiFe  as of this writing  Consult battery mak
24. rs are guaranteed to be free from defects in materials and workmanship for a period of one calendar year from  date of purchase  Your selling dealer is your first point of contact for warranty issues  Return postage costs are the  responsibility of the user in all cases  You MUST submit a copy of original receipt with the charger  and full description of the  problem must also be included in the return package     Damage due to physical shock  dropping on the floor  etc   connection errors due to unauthorized charging configurations   inappropriate power supply  automotive battery charger  etc    water  moisture  and humidity are specifically NOT covered by  warranty  It is well to carefully check your charger and consult your vendor before making a return  as problems in setup   cabling  batteries  or power supply are much more common than defects in the charger     IMPORTANT   If TVC  Terminal Voltage Control Function  setting greater than OmV is used at any time  NO WARRANTY  WILL BE AVAILABLE  nor ANY LIABILITY ACCEPTED for DAMAGE  LOSS  or INJ URY     
25. start to finish  if the charger detects no problem with settings    NORMAL   Charges according to your RATE setting but uses an intelligent algorithm to alter current as needed during charge     Lead Acid Batteries  Set Pb for BATT TYPE  correct voltage at the BATT VOLTS screen and the Ah at the BATT CAPACITY  screen  and amperage at the CHG CURRENT screen  Consult the battery manufacturer   s documentation to determine these  settings     TCS Feature  Terminal Capacity Selection   for Lithium battery types   TCS has two settings  TCS CAPACITY    and TCS END ACTION      The TCS CAPACITY Setting is selected from the MEMORY screen by pressing UP button four times  or DOWN seven times    TCS Capacity can be set from 50  to 100  in 5  increments  default is 100   a full charge   The charger uses your setting  for Battery Capacity in addition to sophisticated measurements and calculations to make a close estimate for the currently  charged capacity in the pack during charging      TCS END ACTION can be set to CONTINUE  default  and STOP  If CONTINUE  when TCS  is reached for settings 50  to  95   the charger will    beep    10 times  but continue charging to 100  until stopped  If TCS ACTION is set to STOP  the charger  will stop charging at that TCS setting and   if balancing is complete   then give COMPLETE  END  Buzzer according to your  buzzer settings   or continue till balanced  then give End buzzer     There are three good reasons why you might want to charge a Lithium Batt
26. ting to a larger square shape  indicating that these cells are being  discharged  while the lower voltage cells are not  Hold down the ENTER to stop balancing at any time     NOTE   SYNC MODE Charging  selected in similar way to SYNC BALANCING above  is intended to be used only with two packs of  the same brand  capacity  type  and lifecycle history  For example  two packs of CX5000 4S lithium polymer purchased at the  same time and used together as a 8S flight pack in series when flying a particular model  At the start of SYNC MODE charging   both packs should be at roughly the same discharge state  Otherwise  you should SOLO MODE charge each pack separately  and  when both are done use SYNC MODE balancing before connecting in series for flight          USER SETUP  these settings are    sticky    until you change them again     Press the MODE button until you reach the USER SETUP   TEMP MODE screen     Press ENTER and use UP or DOWN keys to select temperature display in degrees Fahrenheit or Celsius    Press DOWN to scroll through the following screens  and ENTER then UP or DOWN to change settings on each screen      BUTTON SOUND screen   ON or OFF     FINISH SOUND TIME screen   OFF  ON  continuous   1 Minute  15 Seconds  5 Seconds     FINISH SOUND MELODY screen   Choices 1 to 10  Will also play each Melody      LIPO MAX C screen   Choices of 1C to 5C in 1C steps  2C Default  Allows limiting max LiPo charge C rate as you desire     POWER SUPPLY VOLTAGE screen   Set to limit 
27. w  to three decimal places  for example  3 982    Press ENTER to make the  1CL  flash  and UP to see the voltage for the second cell  third cell  etc      When you have seen the voltage for the last cell in the pack  press DOWN to reach the next screen    AVG  V shows the average voltage per cell  across the whole pack    V  GAP shows the difference between the highest and lowest volt cells in the pack   Press the DOWN button to reach the next screen  which shows voltage for every cell in the pack to two decimal places  x xxv      Press ENTER for two seconds  You will see BALANCE START   SOLO MODE   SYNC MODE       If you are using a single port only  Use UP or DOWN to select SOLO MODE  Hold down the ENTER button  the  charger will check the battery  and then ask you to confirm the number of cells in the pack  If correct  press ENTER once to start  balance charging        If you are using both ports  and want to balance two packs  of same type and capacity   as a single unit   such as 4S  VX4000 and 5S VX4000 to make a 9S series connected flight pack  hold down the ENTER and DOWN key to change from SOLO  MODE to SYNC MODE  Hold down the ENTER to start BATTERY CHECK  The number of cells in each pack will be shown one  above the other  If both are correct  press ENTER to begin balancing     After Balancing has begun  you may return  using UP or DOWN keys  to the screen which shows all cell voltages together  Cells  which are higher in voltage will show the decimal point alterna
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
8919W - Guia do usuário (Win) - PT-BR  ® CUV4X-E USER`S MANUAL    MOBILI`VOLT  ficha tecnica movidur super satinado  Vibromètre portable polyvalent Elivib Pro  Forma Series II 3110 Water-Jacketed CO2 Incubators User Manual  Makita HR2400 User's Manual  Epson Stylus Photo RX560  Enfocus PitStop Pro 11 Level B, 1Y, Maintence    Copyright © All rights reserved. 