1.    6  User s Manual      Manufacturer of the adapter  GlobTek Inc     15    IX  WHAT SHOULD   IF       Failure symptom Cause of the  failure    The pushbutton  is flickering after  it was connected  to the network    The vaporizing  output of the  device has  decreased    The device  vaporizes    but  the ventilator  does not rotate    The device  vaporizes    but  the fan does not  blow out the  aerosol     There is   Check the presence of the interference liquid  distilled water    Refill it if it is  interference needed  Chapter IV  pages 9 and 10     liquid below the   vaporizing   insertion    If you can find the interference liquid  in that case the device is damaged  and  can only repaired in a special service    The vaporizing   Check if you can see white discoloration on the vaporizing insertion   s bottom    insertion is worn   on the vaporizing membrane  If yes  replace the vaporizing insertion   Chapter  IV  pages 9 and 10    The ceramic is   If the replacement of the vaporizing insert had not solved the problem  most   worn likely the replacement of the ceramic is required  Turn to the service    Check if the connecting plug of the ventilator is pushed into the vaporizing unit   not connected to the stop into the vaporizing unit     Water got into   Disconnect the fan  remove the fan  and let it dry  1 day   Try again after the fan  the ventilator gets dry     Other defects Contact the service     Water entered in   Disconnect the fan  remove the fan  and remove 
2.   SHARP OJECT  BECAUSE THAT COULD CAUSE THE DAMAGE OF THE MEMBRANE        v    12    Disinfecting  as occasion requires     Before the first use  or after a long storage  and to avoid re contamination  the device has to be disinfected  occasionally  The way of the disinfecting     VV V Y V Y YV    Make an antiseptic solution from any cold antiseptic  eg  BARRYCIDAL 22  available at a pharmacy    on the  way prescribed for the agent     Clean up the external surface of the vaporizer unit and the hood and the ventilator with a disinfectant  after it  clean it with clear water wetted cloth    Fill up the vaporizing membrane of the vaporizing unit with the solution  and soak it for the agent s prescribed  contact time    Finishing the disinfection from the vaporizing insertion flush out extensively the antiseptic liquid with clear  water    Soak also the plastic and rubbery components into the antiseptic solution for the agent s prescribed contact  time    The disinfected components have to be also flushed extensively with running water    Do over the network adapter  if is needed  occasionally with an antiseptic  mildly wet tissue     Dry the so disinfected device and its accessories    placing them onto clear surface     on air     During the disinfection  take care not to let any water into the connectors of the vaporizing unit  and the    ventilator     If water would get into the adapter during the cleaning or the disinfection  for example if it fell into water by accident  
3.   you should not try to dry out the device  but send it promptly to the service  The device could be in that case damaged     or could cause an electric shock  You MUSTN T attach it again to the network     13    Vl  MAIN TECHNICAL DATAS    Voltage  24 V DC  Performance  14 W  Adaptor  input  100 240V AC    50 60 Hz 0 45A max  output  24V DC 750 mA    Vaporizing frequency     UP 02  UP02 B  UP 02C 2 4 MHz  Particle size   UP 02  UP 02B  UP 02C 5 u MMD  Filling amount  10 ml    Vaporizing output  measured with distilled    water  minimum   UP 02   UP 02B  UP 02C   Operating time pause   Weight  vaporizing unit   adapter   Brutto   Size   Storage temperature     1 ml min  30 30 perc    151g  110g  261g  110 x 50 x5Omm    0  35C    Do not store the device permanently at temperatures under 0 C    because the distilled water in the vaporizer    freezes  and this makes the device temporarily unserviceable     The data  guidelines referring to the device   s electromagnetic immunity  output of the jam  and the  recommended protecting distances and the manufacturer   s statements can be found on the website  of the SANASOL Ltd   www sanasol hu  among the downloads     Manufacturer  SANASOL Kft   u 13  H 8900 Zalaegerszeg  HUNGARY        36 92 511 381 Fax   36 92 511 382    Skype  sanasol2    E mail  info mail sanasol hu    Wlassics Gyula    web  www sanasol hu    14    VII  CONTENT OF THE PACKAGE    1  Vaporizing unit   2  Network adapter    3  Ventilator   4  Hood   5  Cardboard box
4. If the level does  not reach the vaporizing membrane on the bottom of the vaporizing insertion  you have to do the filing up of the device  according to instructions written in Chapter IV  pages 9 and 10      NOTICE     The pushbutton is continuously lighting after it was connected to the network  If the liquid level drops so much  that it would  endanger the functioning  the controlling electronics will disable the functioning  which is shown by the continuously flicker of  the pushbutton after it was connected to the network  In such cases the device can be only used again after it was filled up  with interference liquid     The device has to be disinfected according to section V   page 12  before the first  use     With the applied vaporizer membrane you can vaporize any kind of  water solvent medicine     O O     O O   OQ      Place the silicone drop catcher    onto the end of the tube leading the aerosol in      Take off the cap of the vaporizing unit     Pour the medicine or liquid to be vaporized into the vaporizer insertion  max  10 ml      Put the cap back on the lower part of the vaporizing unit      Flip the ventilator to the cap and connect the ventilator into the socket     lll  THE USE OF DEVICE      Grab the top of the hood and open the legs   one by one  The opened  and fixed position which is    indicated by a click        and with your finger push it into the tube  according to the figure  s         Insert the tube leading the aerosol in    into the opening 
5. It is recommended to perform the sterilization  process written in the Chapter V  page 12   during the replacement of the vaporizing  insertion and the refill ing of the interference  liquid     The replacement of the worn vaporizing insertion  is provided by the manufacturer  See our  availabilitv on the back cover     11    V  CLEANING AND DISINFECTION    THE CLEANING AND DISINFECTION OF THE DEVICE IS EXCLUSIVELY ALLOWED TO BE    PERFORMED IN A STAGE IF IT IS DISCONNECTED  ANNEALED FROM THE MAINS POWER        Cleaning  After every use     Flip the ventilator from the cap before you start the cleaning    Pour out the fluid  which remained in the device as you take off the cap    Rinse the vaporizing insertion with clean water    Wash the plastic components with running water    Do the cleaning of the ventilator and the hood only with wet cloth    Placing the cleaned device and its accessories onto clean surface dry them on air     Y Vv Vv Vv Vv v    Wash the air filter of the ventilator  if it is needed  occasionally with running water   The filter should be replaced only after it is completely dried    Change the worn or damaged filter   Is available at the manufacturer     A blocked filter reduces the air transport     Do not use other agents  petrol  solvent etc  for the cleaning   Take care that no water should get into connectors of vaporizing unit  and into the ventilator     DURING THE CLEANING AND THE DISINFECTION  TAKE CARE NOT TO TOUCH THE RUBBERY MEMBRANE WITH A  
6. USER MANUAL    for  UP 02D  ultrasonic nebulizer    m    SANASOL  Verz  01         C     0197    GENERAL INFORMATION    Thank you for choosing SANASOL   s device  The UP 02D ultrasonic medicine vaporizer was  developed for vaporizing water solvent medication  medicinal waters and physiological saline solution  for infants  until they will be 2 years old  The arising aerosol gets into the respiratory tracts with the  help of the inhalation hood    The vaporization of the fluid is performed by a piezo ceramics  with the help of interference liquid  and a vaporizing membrane  The size of the generated particle makes it possible that the medicine  gets even into the bronchus    The vaporization of medication is very economical  the device works efficiently until the last drop   The device is suitable for the treatment of bronchitis  asthma bronchiale  laryngitis  pSeudocroup   mucoviscidosis etc   or to prevent pneumoconiosis     While the using the constant watch of an adult is required     Before the use of the device  read carefully this User   s Manual  and keep the ones written in there  while using it  in order for that your device can serve the longer     With question  suggestion or complaint  turn to us with trust     Zalaegerszeg  15 May  2008   Gabor N  meth  Executive Director    I CONSTRUCTION OF THE DEVICE    The UP 02D ultrasonic personal nebulizer consists of three main parts     1  The vaporizing unit 2  Network adapter       3  Inhalation hood       The vaporizi
7. air or replace  the defect product or its defective parts    The guarantee does not cover any of the following    o Transport costs and risk of transport    o Costs for repairs and or defects resulting from repairs done by unauthorised persons  Should guarantee service be  required please apply to the retailer wnom the product was purchased from for an authorised SANASOL distributor   For the address refer to the product packaging attached literature or to your specialised retailer  If you have difficulties  in finding SANASOL Kft   contact us for information    Periodic check ups  maintenance and repair   Failure or wear of accessories or attachments other than the main device itself  unless explicitly guaranteed above   Costs resulting from non acceptance of a claim    o Damages of any kind including personal caused accidentally or from misuse   Repair or replacement under the guarantee does not give rise to any extension or renewal of the guarantee period   The guarantee will be granted only if the complete product is returned together with the guarantee card and the original  invoice cash ticket issued to the consumer by the retailer and customer  The guarantee card must be completed in full and  SANASOL reserves the right to refuse guarantee service if any unclear information has been given   SANASOL Kft  becomes the owner of all exchanged parts or units     O O O     SANASOL Kft   Wlassics Gy  13   H 8900 Zalaegerszeg  Hungary  Phone   92  511 381 Fax   92  511 382 E ma
8. il  info mail sanasol hu    19    GUARANTEE DOCUMENT    Product name  ULTRASONIC MEDICINE NEBULIZER   Type  UP 02D   Product serial number    Manufacturer  SANASOL Kft  Wlassics Gy u  13  8900  Zalaegerszeg  HUNGARY    Date of purchase           day                     month           year  signature stamp of retailer  SERVICE     SANASOL Kit    8900  Zalaegerszeg  Wlassics Gy u  13  HUNGARY    _ 1  36 92 511 381 Fax   36 92 511 382  E mail  info mail sanasol hu  Skype  sanasol2    
9. ng unit consists of the following parts     A vaporizer house  B vaporizer cap  C ventilator    On the vaporizer house you can find    gt  The operating button   1     gt  The vaporizer insertion made from silicone rubbe    2   and on its base you can find    gt  The vaporizer membrane  3        You can find on the removable vaporizing cap the opening c  the suction house 4  and the air inlet bores  5      The hood consists of the following parts     e Transparent hood     The hood consists of a truss made from plastic and a plastic foil  which covers it   e Tube leading the aerosol in    This tube can be set up in every direction  and ensures so that in the    vaporizer arisen aerosol gets directly into the infant s nose and mouth     The hood    Legs  Transparent plastic cover  Openable part    Tube leading the aerosol in        Adjuster head for the suction house  Tube leading the aerosol in  Silicone rubbery drop catcher  Suction house    5    ll  FIRST INSTALLATION OF THE DEVICE    Interference liquid  distilled water  between the piezo ceramic and the vaporizing insertion is required for the working of the  vaporizer  The manufacturer fills up the device during the production  This inserted liquid may decrease during the use and  the storage  Since there can elapse a notable period between the manufacture and the use  so it can happen that this liquid  level drops off already before the first use  Therefore at the first use check the factory filled liquid   s presence  
10. on the hood s top          Connect the adapter first to the vaporizing unit  then to the network       Connect the suction house   to the adjuster head  according to the figure   k    s        11  Insert the adjuster head    to the tube leading the aerosol in     At the  inserting pay attention to that the little protruding part on the adjuster head    should enter in one of the cuts on the side of the tube leading the  aerosol in        12  Place the hood on the baby so that the openable part should be into the  direction of its body    13  Posture the tube leading the aerosol in   so that its end should be    approximately 5 centimetres far from the baby   s nose  mouth   14  Insert the suction house   s other end into the opening of the vaporizer device        15  By pressing the pushbutton of the vaporizer device you can start the  treatment     Pressing the pushbutton again for a short time the vaporization will stop  The vaporization automatically stops  also after 10 minutes are over  If the liquid to be vaporized is not consumed  or you would like to continue the  treatment after filling it up again  the vaporization can started again by pressing the pushbutton repeated for a  short time     Important information and warnings relating to the use of the device    Only by the doctor recommended medicine  and only in the prescribed dilution can be vaporized    The device contains small sized components too  At dissembling keep them on such places  where the  baby could n
11. ot reach it    The vaporizing unit and the hood should be cleaned after each use  The cleaning process can be found  in the Section V  page 11    Occasionally you can leave the unused medicine in the device until tthe next  use this does not damage the device     If the level of the interference liquid in the vaporizing unit drops so much that the vaporizing membrane of  the vaporizing insertion already doesn t reach into it  the interference liquid has to be refilled  Refilling  has to be made as it is written in Chapter IV  page 9     During the use the vaporizing insertion becomes worn due to the ultrasonic effect  small cracks appear in  the material of the vaporizing membrane in the form of white discolouration on the surface of the  membrane   This causes the reduction of the vaporizing performance in this case the vaporizing  insertion has to be replaced  Replacement must be made as written in the Chapter IV  page 8         DO NOT OPERATE THE DEVICE WITH BROKEN OR DAMAGED COVER     If there would be any problem in connection with using the device  before turning to the service        look as written in the Chapter IX  paqe 15      IV  REFILLING OF THE INTERFERENCE LIQUID  REPLACEMENT OF THE VAPORIZING INSERTION    If the vaporizing insertion becomes worn during use due to the ultrasonic effect  white discolouration can be seen  on the rubbery membrane surface of the vaporizer   or the interference liquid s level in the vaporizing unit so  much that the vaporizing inser
12. the liquid from the air inlet  the air inlet ports   ports by blowing them out    of the vaporizing   lid       16    X  SYMBOLS USED ON THE DEVICE   N WARNING  Read the Instruction Manual  and comply with those written in it     K B type device    E II  Class of protection against indirect contact  dual insulation     i    Manufacturer       17    Declaration of conformity m K SANASOL    Manufacturer   Address     Product typ   Serial number     Class     SANASOL Meditechnika Kft    Wlassics Gy  13  H 8900 Zalaegerszeg  HUNGARY  Phone   36 92 511 381 Fax   36 92 511 382  e mail  info mail sanasol hu web  www sanasol hu    UP 02D Ultrasonic nebulizer    ll a  according to the Rule 11 of Annex IX of 93 42 ECC Directive     We herewith declare on our sole responsibility that above product complies with the requirements of  EC Directive 93 42 EEC     Applied standards     Notified body     Certificate No   Certificate date     Date of Issue     CE ow    For applies standards  please refer to Chapter IV  of the Technical  Construction File     TUV Rheinland Product Safety GmbH  Am Grauen Stein  51105 Koln  Notified Body No  0197   DD 60022053 0001  28  Aug  2008   01  Sept  2008   Issued by   Managing Director  Gabor Nemeth    18    GUARANTEE    A period of 1 year for the unit after the date of purchase the proper construction  workmanship and materials of this product is  guaranteed by SANASOL  During this period of guarantee SANASOL will  without charge for labour or parts  rep
13. tion made from silicone rubbery doesn t reach into it  the device has to be  disassembled  and the vaporizing insertion has to be replaced  and the interference liquid has to be refilled  The  replacement and the refill have to be done in the following way        f   gi a 1  Insert the blank attached   K iA to the device into the slots      3x2  on the inner side of the   fixing ring of the vaporizing 3   insertion  7 SSS  oft    3  If the fixing ring  has not lifted out  the vaporizing  insertion  remove it  from its place           4  Pour out the fluid  which can be found even    2  Screw out the there   ring anticlockwise  5  If it is needed clean the inner surface of the  tank        Do the cleaning with a wet or alcoholic  cloth  do not use any other agent     10    6  Fill up the tank with  25 ml distilled water   For the refilling it is  recommended to use  a syringe        Attention   Do not use a needle in the syringe during  refilingl to avoid damages to the vaporizing  insertion     Be careful not to touch the golden surfaced  ceramic with a hard object        7  Replace the  vaporizing insertion   If the old one is  worn  replace it with  a new one           8  Screw back the  fixing ring  and tighten  it with the attached  blank     ATTENTION  The lifetime of the vaporizing  insertion is significantly reduced  if the device is  run empty  without fluid to be vaporized  So if the    flui  medicined to be vaporized    is out  do not  use the device further        
    