1. KRAMER ELECTRONICS LTD USER MANUAL MODEL RC 76M RC 712M P N 2900 300329 Rev 3 Elri RC 76M RC 712M Quick Start Guide This guide helps you install and use your product for the first time For more detailed information lt I go to http www kramerelectronics com support product downloads asp to download the latest m manual or scan the QR code on the left Step 1 Check what s in the box amp RC 76M and or RC 712M Room Controller 2 1 Quick start guide F Button labels sheets A 1 12V DC power supply Step 2 Install the device i 1 Configure the buttons using Kramer the K Config configuration software 2 Place the device in the Merten housing 3 Connect the inputs and outputs to their appropriate devices using terminal block connectors 2 RS 232 1 RS 485 1 GPI O 1 K NET 1 Ethernet RJ 45 2 infrared 2 relays DVD Player IR DVD Player Projector RS 485 IR Room Motion Detector Controller GPI O K NET Lighting aa Relay LCD Display Projector Screen RS 232 RS 232 Relay 4 Connect the 12V DC power 5 Insert the labels under the button caps 6 Fix the frame and faceplates Step 3 Operate the device Operate the unit via the front panel buttons or remotely by AUX keypad over K NET or from the Web page from any PC over the Ethernet connection Contents 1 Introduction 2 Getting Start
2. Button Cap Orientation with Label 6 Retaining this orientation place each button cap with the label to its correct button see Figure 10 Figure 10 Placing the Button Caps and Mounting the Device 7 Place the faceplates over the frame while fitting the buttons in for the RC 76M you need to attach one button faceplate and one blank faceplate see Figure 11 Figure 11 Placing the Faceplates 8 Tighten the two M3x16 screws with Allen key supplied to fix the faceplates and the frame to the housing see Figure 12 Note that if you need to reconfigure the buttons simply remove these two screws and remove the frame and faceplate to gain access to the IR learner and USB port Figure 12 Securing the Frame and Faceplates RC 76M RC 712M Installing the RC 76M RC 712M EI Operating the RC 76M RC 712M You can operate your RC 76M RC 712M via the front panel buttons or remotely by AUX keypad over K NET The front panel buttons are configured using the K Config software For instructions on using the software see the K Config Software Guide available from our Web site www kramerelectronics com 6 Front Panel Button Labels The RC 76M RC 712M are supplied with a button label sheet and 6 8 clear button caps to house the labels Figure 13 illustrates a sample button label sheet K KRAMER sw ELECTRONICS cD MEDIA PLAYER PLAYER WALL AUTO LIGHTS LIGHTS LIGHTS LIGHTS 1 a 2 2 3 OFF ON OFF POWER POWER
3. the K Config Software Guide Available from our Web site at http www kramerelectronics com support product downloads asp 4 4 4 5 Connecting the K NET Port The K NET port is wired as shown in Figure 5 K NET PINOUT If your device is the first or last K NET G B A12V device on the line slide the K NET termination switch up otherwise make sure it is set to down see Figure 1 Black GND Figure 5 K NET PINOUT Connection Mounting the RC 76M RC 712M onto the Merten Housing After the cables are connected you can mount the device onto the housing Note that the illustrations in this section do not show the cables that are already connected to the device and passing through the housing cable openings To mount the RC 76M RC 712M 1 Reconnect the detachable terminals to the rear panel 2 Gently place the RC 76M RC 712M inside the housing making sure that all cables remain connected Figure 6 Inserting the RC 76M RC 712M RC 76M RC 712M Installing the RC 76M RC 712M 3 Secure the unit to the housing by screwing the four 3 5x10 conical Philips screws supplied with the unit into their 4 designated holes see Figure 7 Figure 7 Securing the RC 76M RC 712M Figure 8 4 Mount the frame over the device see Figure 8 Placing the Frame 5 Insertthe labels as reguired inside the button caps while holding the button cap wings to the sides as shown in Figure 9 ON Figure 9
4. 000 plus different models now appear in 11 groups that are clearly defined by function GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Routers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Specialty AV Products GROUP 7 Scan Converters and Scalers GROUP 8 Cables and Connectors GROUP 9 Room Connectivity GROUP 10 Accessories and Rack Adapters and GROUP 11 Sierra Products Congratulations on purchasing your Kramer RC 76M and or RC 712M which are ideal for the following typical applications e Remote control and management of AV equipment in multimedia rooms such as classrooms auditoriums conference rooms 2 2 1 Getting Started We recommend that you e Unpack the equipment carefully and save the original box and packaging materials for possible future shipment e Review the contents of this user manual Go to http www kramerelectronics com support product downloads as i to check for up to date user manuals application programs and to check if firmware upgrades are available where appropriate Achieving the Best Performance To achieve the best performance Use only good quality connection cables we recommend Kramer high performance high resolution cables to avoid interference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables e Do not secure the ca
5. Figure 1 defines the front panel of the RC 76M RC 712M 00 80 006 O a m O 0O 8606 686 O 00000 Das sa Figure 1 RC 76M RC 712M Room Controller Front Panel Feature Function 1 6 12 Configurable Buttons Button function is programmed by the K Config Configuration software 2 IR IN Built in IR Receiver Use to learn the IR commands from a machine s remote control transmitter 3 USB Connector Connect to a computer for firmware upgrade or for uploading the configuration file Button Cover Plate To secure the faceplates and frame to the Merten compatible housing Remove to access the USB ports and IR learner RC 76M RC 712M Overview es Mounting Screw holes 2 Figure 2 defines the rear panel of the RC 76M RC 712M iala OLS C 86 BEN sae 2 80666 60 58 Figure 2 RC 76M RC 712M Room Controllers Rear Panel Feature Function K NET Terminal Block Connector Connect the GND pin to the Ground connection pin B and pin A are for RS 485 and the 12V pin is for powering the unit RS 485 Terminal Block Connector Pins B and A are for RS 485 Pin G may be connected to the shield if required 7 ETHERNET RJ 45 Connector Connects to the PC or other serial controller through computer LAN to control AV products RELAY C1 Connect to low voltage relay driven device 1 GPIO GND Terminal Block Connect to various sen
6. STANDBY ON OFF ON OFF Cat No 2808 000035 RC 76M RC 712M Front Panel Button Labels DISPLAY OFF DISPLAY CYCLE VOLUME SOURCES DOWN ASPEGT INPUT SELEGT MUSIC SYSTEM CONTROL ALL ON ALL OFF PLAYER DISPLAY DISPLAY 1 DISPLAY 2 DISPLAY 3 DISPLAY 4 PROJEGTOR LANGUAGE ACCEPT ENE NENEI Honk kuni E Ga LAPTOP LAPTOP 1 LAPTOP 2 m m D Cat No 2808 000035 Page 2 RC 76M RC 712M Front Panel Button Labels TABLET VCR 1 VCR 2 BLU RAY TA RAY t RAY a DVD 1 DVD 2 CAMERA CAMERA 1 CAMERA 2 DOC CAM PA vm 9 Oa jae a Ki KON Ats 9 Cat No 2808 000035 Page 3 Figure 13 Sample Button Label Sheet js O gt MO Se Os Ors ae cr ojja 78 RC 76M RC 712M Front Panel Button Labels 7 Technical Specifications 2 RS 232 1 RS 485 1 GPI O and 1 K NET on terminal block connectors 1 Ethernet on an RJ 45 connector 1 USB for programming OUTPUTS 2 IR 2 relays 36V AC or DC 2A 60VAC maximum on non inductive load DEFAULT IP SETTINGS IP number 192 168 1 39 Mask 255 255 0 0 Gateway 0 0 0 0 POWER CONSUMPTION OPERATING TEMPERATURE 0 to 40 C 32 to 104 F STORAGE TEMPERATURE 40 to 70 C 40 to 158 F HUMIDITY 10 to 90 RHL non condensing DIMENSIONS 7 9cm x 2 8cm x 12 4cm 3 1 x 1 1 x 4 9 W D H with wall plate WEIGHT 0 245kg 0 54lbs approx ACCESSORIES Power supply button caps button labels OPT
7. ANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IF KRAMER ELECTRONICS CANNOT LAWFULLY DISCLAIM OR EXCLUDE IMPLIED WARRANTIES UNDER APPLICABLE LAW THEN ALL IMPLIED WARRANTIES COVERING THIS PRODUCT INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SHALL APPLY TO THIS PRODUCT AS PROVIDED UNDER APPICABLE LAW IF ANY PRODUCT TO WHICH THIS LIMITED WARRANTY APPLIES IS A CONSUMER PRODUCT UNDER THE MAGNUSON MOSS WARRANTY ACT 15 U S C A 2301 ET SEQ OR OTHER APPICABLE LAW THE FOREGOING DISCLAIMER OF IMPLIED WARRANTIES SHALL NOT APPLY TO YOU AND ALL IMPLIED WARRANTIES ON THIS PRODUCT INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR THE PARTICULAR PURPOSE SHALL APPLY AS PROVIDED UNDER APPLICABLE LAW Other Conditions This limited warranty gives you specific legal rights and you may have other rights which vary from country to country or state to state This limited warranty is void if i the label bearing the serial number of this product has been removed or defaced ii the product is not distributed by Kramer Electronics or iii this product is not purchased from an authorized Kramer Electronics reseller If you are unsure whether a reseller is an authorized Kramer Electronics reseller please visit our Web site at www kramerelectronics com or contact a Kramer Electronics office from the list at the end of this document Your rights under this limited warranty are not diminished if you do not complete and ret
8. IONS Merten compatible 2 gang on wall box housing and frame P N OWB 2G M Specifications are subject to change without notice at http www kramerelectronics com LIMITED WARRANTY The warranty obligations of Kramer Electronics for this product are limited to the terms set forth below Whatis Covered This limited warranty covers defects in materials and workmanship in this product What is Not Covered This limited warranty does not cover any damage deterioration or malfunction resulting from any alteration modification improper or unreasonable use or maintenance misuse abuse accident neglect exposure to excess moisture fire improper packing and shipping such claims must be presented to the carrier lightning power surges or other acts of nature This limited warranty does not cover any damage deterioration or malfunction resulting from the installation or removal of this product from any installation any unauthorized tampering with this product any repairs attempted by anyone unauthorized by Kramer Electronics to make such repairs or any other cause which does not relate directly to a defect in materials and or workmanship of this product This limited warranty does not cover cartons equipment enclosures cables or accessories used in conjunction with this product Without limiting any other exclusion herein Kramer Electronics does not warrant that the product covered hereby including without limitation the techno
9. bles in tight bundles or roll the slack into tight coils e Avoid interference from neighboring electrical appliances that may adversely influence signal quality e Position your Kramer RC 76M RC 712M away from moisture excessive sunlight and dust This equipment is to be used only inside a building It may only be connected to other equipment that is installed inside a building 2 2 2 3 safety Instructions Caution There are no operator serviceable parts inside the unit Warning Use only the Kramer Electronics input power wall adapter that is provided with the unit Warning Disconnect the power and unplug the unit from the wall before installing Recycling Kramer Products The Waste Electrical and Electronic Equipment WEEE Directive 2002 96 EC aims to reduce the amount of WEEE sent for disposal to landfill or incineration by requiring it to be collected and recycled To comply with the WEEE Directive Kramer Electronics has made arrangements with the European Advanced Recycling Network EARN and will cover any costs of treatment recycling and recovery of waste Kramer Electronics branded equipment on arrival at the EARN facility For details of Kramer s recycling arrangements in your particular country go to our recycling pages at htip www kramerelectronics com supportrecycling Overview The RC 76M and RC 712M are six and twelve button configurable room controllers for multimedia rooms They control audio
10. components video components and other room facilities such as lights and screens They are designed to be installed in compatible Merten System M on wall boxes frame and housing RC 76M RC 712M features e 6 12 configurable buttons RGB backlit front panel buttons configured using the K Config configuration software e 1 GPI O port that can be configured by K Config configuration software as a digital input digital output or analog input for interfacing with a variety of devices such as sensors switches LEDs or relays e Kramer Site CTRL compatibility for network remote control and management over the Ethernet port e 2 bidirectional RS 232 ports for the control of AV equipment such as projectors LCD and PDP displays power amplifiers switchers and scalers e 2 relay contact closure ports for the control of other room items related to an AV system such as raising and lowering drapes a screen or a projector e 2 IR control ports with an IR learning receiver on the front panel that learns commands from any IR remote e 1 RS 485 port e AK NET control channel that connects compatible user interfaces supplies power and controls data over a single cable e A USB port located on the front panel to connect to a computer for firmware upgrade or for uploading the configuration file e Flexible control via Ethernet and K NET e Wall Plate Size 2 gang EU Merten compatible 3 1 Defining the RC 76M RC 712M Room Controllers
11. ed 2 1 Achieving the Best Performance 2 2 Safety Instructions 2 3 Recycling Kramer Products 3 Overview 3 1 Defining the RC 76M RC 712M Room Controllers 4 Installing the RC 76M RC 712M 4 1 Configuring the Room Controller Buttons 4 2 Mounting the Device 4 3 Connecting the Ethernet Port 4 4 Connecting the K NET Port 4 5 Mounting the RC 76M RC 712M onto the Merten Housing 5 Operating the RC 76M RC 712M 6 Front Panel Button Labels 7 Technical Specifications Figures Figure 1 RC 76M RC 712M Room Controller Front Panel Figure 2 RC 76M RC 712M Room Controllers Rear Panel Figure 3 Merten Compatible Housing Figure 4 Connecting the RC 712M Figure 5 K NET PINOUT Connection Figure 6 Inserting the RC 76M RC 712M Figure 7 Securing the RC 76M RC 712M Figure 8 Placing the Frame Figure 9 Button Cap Orientation with Label Figure 10 Placing the Button Caps and Mounting the Device Figure 11 Placing the Faceplates Figure 12 Securing the Frame and Faceplates Figure 13 Sample Button Label Sheet OOO GI A OONN met ek n Php N m O NO Introduction Welcome to Kramer Electronics Since 1981 Kramer Electronics has been providing a world of unigue creative and affordable solutions to the vast range of problems that confront video audio presentation and broadcasting professionals on a daily basis In recent years we have redesigned and upgraded most of our line making the best even better Our 1
12. hat Kramer Electronics will not do Under This Limited Warranty If this product is returned to Kramer Electronics or the authorized dealer from which it was purchased or any other party authorized to repair Kramer Electronics products this product must be insured during shipment with the insurance and shipping charges prepaid by you If this product is returned uninsured you assume all risks of loss or damage during shipment Kramer Electronics will not be responsible for any costs related to the removal or re installation of this product from or into any installation Kramer Electronics will not be responsible for any costs related to any setting up this product any adjustment of user controls or any programming required for a specific installation of this product How to Obtain a Remedy under this Limited Warranty To obtain a remedy under this limited warranty you must contact either the authorized Kramer Electronics reseller from whom you purchased this product or the Kramer Electronics office nearest you For a list of authorized Kramer Electronics resellers and or Kramer Electronics authorized service providers please visit our web site at www kramerelectronics com or contact the Kramer Electronics office nearest you In order to pursue any remedy under this limited warranty you must possess an original dated receipt as proof of purchase from an authorized Kramer Electronics reseller If this product is returned under this limited warranty a ret
13. in 3 to RX and pin 5 to GND on the RS 232 terminal block connector of the RC 76M 10 RC 76M RC 712M Installing the RC 76M RC 712M 4 2 1 2 Connecting RS 485 Devices You can control up to one AV device by connecting it to the RC 76M RC 712M via its RS 485 connection To connect a device to the RC 76M RC 712M via RS 485 e Connect the A pin of the device to the A pin on the RS 485 terminal block of the RC 76M RC 712M e Connect the B pin of the device to the B pin on the RS 485 terminal block of the RC 76M RC 712M e Connect the G pin of the device to the GND pin on the RS 485 terminal block of the RC 76M RC 712MRC 76M If your device is the first or last device on the line slide the RS 485 termination switch up otherwise make sure it is set to down see Figure 1 4 3 Connecting the Ethernet Port The Ethernet connection of the RC 76M RC 712M lets you perform all control functions of the RC 76M RC 712M over the Internet using a PC running the Kramer Site CTRL control program to control AV devices To connect the RC 76M RC 712M to a network 1 Connect the Ethernet port of the RC 76M RC 712M to the Ethernet port ona network hub or network router via a straight cable with RJ 45 connectors 2 Atthe other end connect the Internet to a PC running Site CTRL 3 After connecting the Ethernet port you have to install and configure it For detailed instructions on how to install and configure your Ethernet port see
14. logy and or integrated circuit s included in the product will not become obsolete or that such items are or will remain compatible with any other product or technology with which the product may be used How Long Does this Coverage Last Seven years as of this printing please check our Web site for the most current and accurate warranty information Who is Covered Only the original purchaser of this product is covered under this limited warranty This limited warranty is not transferable to subsequent purchasers or owners of this product What Kramer Electronics will do Kramer Electronics will at its sole option provide one of the following three remedies to whatever extent it shall deem necessary to satisfy a proper claim under this limited warranty 1 Elect to repair or facilitate the repair of any defective parts within a reasonable period of time free of any charge for the necessary parts and labor to complete the repair and restore this product to its proper operating condition Kramer Electronics will also pay the shipping costs necessary to return this product once the repair is complete 2 Replace this product with a direct replacement or with a similar product deemed by Kramer Electronics to perform substantially the same function as the original product 3 Issue a refund of the original purchase price less depreciation to be determined based on the age of the product at the time remedy is sought under this limited warranty W
15. n caps with labels e Place the frame e Attach the faceplates Configuring the Room Controller Buttons Configure the 6 buttons for RC 76M and 12 buttons for RC 712M using the K Config configuration software via the USB port that is located on the front panel on the board or the Ethernet port located on the rear panel Use the IR learning receiver on the front panel to read IR commands from any IR remote control Note that the device needs to be connected to the power to configure the buttons The K Config user guide is available on our Web site at http www kramerelectronics com support product downloads as We recommend that you configure the buttons before mounting the device onto the Merten compatible on wall box Mounting the Device This section describes how to mount the RC 76M RC 712M onto the Merten compatible on wall box sold by Kramer P N OWB 2G M Connecting the Ports The following diagrams illustrate a compatible 2 gang on wall box but installation is similar with any compatible wall box We recommend that you first detach the male connectors from the rear panel connect the relevant wires to them and then reconnect the assembled male terminals to the unit just before installation in the on wall box Pass the appropriate cables through any of the four housing cable pass through openings on the sides of the box see Figure 3 Pass through Opening Figure 3 Merten Compatible Housing Always swi
16. sors switches LEDs or Connector relays IR 2 Terminal Block Connector Connect to IR emitter cable 2 1 IR 1 Terminal Block Connector Connect to IR emitter cable 1 2 Power Supply 2 pin Terminal Connect 12V to 12V ground to GND Block Connector RS 485 Terminator Switch Slide the DIP switch up to terminate the RS 485 line with a 1200 load down is for no termination K NET Terminator Switch Slide the DIP switch up to terminate the K Net line with a 1200 load down is for no termination RS 232 1 Terminal Block Connects to a PC or the remote controller Connector 16 RS 232 2 Terminal Block Connects to a PC or the remote controller Connector Program Switch For technical support use only should be set downwards for normal operation C 76M RC 712M Overview oO 4 oo l N OI gt Feature Function 18 RESET Button Press to reset to factory default definitions IP number 192 168 1 39 Mask 255 255 0 0 Gateway 0 0 0 0 First disconnect the power supply and then connect it again while pressing the Reset button The unit powers up and loads its memory with the factory default definitions and erases all stored preset RELAY C2 Connect to low voltage relay driven device 2 4 4 1 4 2 4 2 1 Installing the RC 76M RC 712M To install the RC 76M RC 712M e Configure the buttons e Connect the cables e Mount the room controller onto the Merten compatible housing e Attach butto
17. tch off the power to each device before connecting it to your RC 76M RC 712M After connecting your RC 76M RC 712M connect its power and then switch on the power to each device Although the illustration in Figure 4 shows the RC 712M the following example applies also to the RC 76M To connect the RC 76M RC 712M as illustrated in the example in Figure 4 1 Connect the IR outputs as follows Connect an IR emitter to IR OUTPUT 1 and attach the emitter to the DVD player 1 Connect an IR emitter to IR OUTPUT 2 and attach the emitter to the DVD player 2 2 Connect the RS 232 ports see Section 4 2 1 1 as follows Connect RS 232 port 1 to the projector Connect RS 232 port 2 to the plasma display 3 Connect the RELAY terminal block connectors as follows Connect RELAY C and 1 to the screen Connect RELAY C and 2 to the lighting system 4 Connect the GPI O 1 port to a motion detector 5 Connect the Ethernet port to a network To power supply Ethernet DVD DVD LCD Display C gt gt p Relay RS 232 gt J LO wi N x Motion Projector Detector Screen Lighting System Figure 4 Connecting the RC 712M 4 2 1 1 Connecting RS 232 Devices You can control up to two AV devices such as a projector or an RS 232 display by connecting them to the RC 76M RC 712M via their RS 232 connection To connect a device to the RC 76M RC 712M via RS 232 e Using a straight cable connect pin 2 to TX p
18. urn authorization number obtained from Kramer Electronics will be required You may also be directed to an authorized reseller or a person authorized by Kramer Electronics to repair the product If itis decided that this product should be returned directly to Kramer Electronics this product should be properly packed preferably in the original carton for shipping Cartons not bearing a return authorization number will be refused Limitation on Liability THE MAXIMUM LIABILITY OF KRAMER ELECTRONICS UNDER THIS LIMITED WARRANTY SHALL NOT EXCEED THE ACTUAL PURCHASE PRICE PAID FOR THE PRODUCT TO THE MAXIMUM EXTENT PERMITTED BY LAW KRAMER ELECTRONICS IS NOT RESPONSIBLE FOR DIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY OR CONDITION OR UNDER ANY OTHER LEGAL THEORY Some countries districts or states do not allow the exclusion or limitation of relief special incidental consequential or indirect damages or the limitation of liability to specified amounts so the above limitations or exclusions may not apply to you Exclusive Remedy TO THE MAXIMUM EXTENT PERMITTED BY LAW THIS LIMITED WARRANTY AND THE REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES REMEDIES AND CONDITIONS WHETHER ORAL OR WRITTEN EXPRESS OR IMPLIED TO THE MAXIMUM EXTENT PERMITTED BY LAW KRAMER ELECTRONICS SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCH
19. urn the product registration form or complete and submit the online product registration form Kramer Electronics thanks you for purchasing a Kramer Electronics product We hope it will give you years of satisfaction For the latest information on our products and a list of Kramer distributors visit our Web site where updates to this user manual may be found We welcome your guestions comments and feedback Web site www kramerelectronics com KRAMER E mail info Okramerel com SAFETY WARNING Disconnect the unit from the power e supply before opening and servicing P N 2900 300329 Rev 3