Home

USER MANUAL LL PRO LED GRAPHIC PANEL - sal

image

Contents

1. Heigrbreadth from combustible materials is 0 5m The LL PRO LED GRAPHIC PANEL is designed for use in a 600mm grid suspended ceiling with T profile Figure Nr 1 1 Edition A 2008 If you have any question please contact support leaderlight sk 03 3 Connecting to AC power A To tackle all Safety Information 01 For protection from electric shock the device must be grounded earthed Itis not necessary to open the fixture before power supply Power supply is sovied simple with Neutrik PowerCon connectors The fixture is equipped with auto switching power supply that automatically adjusts to any 50 60 Hz AC power source from 100 260 Volts insert into suspended Cord plug connections ceiling with T profile Control ta Symbol Pin Wire Colour Screw US wee L live brown black black N neutral light blue white ground earth yellow green green 03 4 Control data connecting Control data cable length is specified by Norm IEC929 Annex E4 It is not necessary to open the fixture before connecting of DMX512 control signal Interconnections are realized by Neutrik XLR 5 PIN IN OUT connectors 03 5 DMX channels Custom made solution is on separate document 04 MAINTENANCE A To tackle all Safety Information 01 Damage caused by inadequate cleaning or maintenance is not coverd by warranty Regular cleaning is demand dust dirt Maintenance po
2. LxWxH 588mm x 588mm x 129 5mm IP IP20 Maximum 40 C Control data Input Input power Ambient temp Ta Coolong Conventional Materials and finish Housing anodized aluminium black Cover plexiglass with special diffuse foile Installation Surface recesed or semi recesed mounting 02 2 Data and Power connections Power OUT Power IN PowerCon PowerCon DMX OUT XLR 5PIN DMX IN XLR 5PIN 02 3 Top panel Control LEDs T POWER DATA MODE amp ADDRESS 6 0 06 Dip options 100 10 1 Rotating DIP address 000 511 Control LEDs Indication POWER DATA LED INDICATION STATUS POWER Red blinking 2Hz OK inside fixture is everything correct DATA Green light off NO DMX512 signal DATA Green blinking 4Hz OK income correct DMX512 signal DATA Green fast blinking NON correct digital signal POWER Red alternate blinking Autotest function DATA Green 03 INSTALLATION 03 1 Unpacking Unpack carefully This is electronic equipment and should be handled carefully Damaged delivered package or if are any mechanical parts broken it must be claim immediately by the transport company Photo pictures as evidence are valuable for future claim 03 2 Physical installation Loading capacity of bearing area has to be at least 10 times the weight of all device clusters luminaries clamps cables
3. Leader Light s r o M Gorkeho 33 SK 052 01 Spisska Nova Ves Slovakia www leaderlight eu USER MANUAL LL PRO LED GRAPHIC PANEL RGB RGBAW Tr LL50 455 COMPLIMENTS ON YOUR PURCHASE LEADER L GHT professional lighting products All dimensions are in milimeters 588 gt _1295 588 Following items are included LL PRO LED GRAPHIC PANEL RGB RGBAW 1 pe PowerCon type A B 1 pc User manual 1 pe Additional items needed Data cables with XLR 5PIN Female Male 1 pc Controller compatible with DMX 1 pc Content 01 SAFETY INFORMATION 01 1 Risk of eyes damage 01 2 Protection from electric shock 01 3 Fire prevention 02 PRODUCT SPECIFICATION 02 1 Technical Specification 02 2 Data and Power connections 02 3 Top panel 03 INSTALLATION 03 1 Unpacking 03 2 Physical installation 03 3 Connecting to AC power 03 4 Control data connecting 03 5 DMX channels 04 MAINTENANCE ENVIRONMENT RY Do not throw away the appliance with the normal household waste at the end of its life but hand it in at an official collection point for recycling By doing this you help to preserve the environment MMVIII Leader Light All right reserved 01 SAFETY INFORMATION Ad WARNING Carefully read before installing powering or servicing Nothing to do if anything misunderstand Only for professional use 01 1 Risk of eyes damage A Do not look directly int
4. licy Unplug mains befor maintenance and at least 10 minutes cool off Cleanup dust from scuttle diffuser and lens Use vacuum or dampy duster warm watter Before reinstalling to check failure free state no wet parts If you have any question please contact support leaderlight sk
5. o LED lamps Do not look into light beam from a distance of less than 40 cm 16 inches 01 2 Protection from electric shock A Shut down power before installation or maintenance Luminaries and recommended power supply must be installed by a qualified professional in accordance with relevant local codes Only acceptable source of AC power and frequency that complies with local buidling and electrical codes to use Do not use or do not connect the products if the power cable power plug or fixtures are any way damaged wet or if they are overheating Do not modify alter or attempt to service the LeaderLight appliance Doing so will void the warranty Before removing or installing any cover or part of appliance disconnect it from AC power Appliance allways connect to earth eltech 01 3 Fire prevention A Follow all safety consideration Thermostatic switches or fuses never to bypass Device never shield minimum distance around fitting must be 100mm 4 in LEDs never direct cover with filters or other materials Allowing max ambient temperature is 40 C 104 F 02 PRODUCT SPECIFICATION 02 1 Technical Specification Lamp type RGB 144 x RGB TOP LED Red Green and Blue RGBAW 432 x RGBAW TOP LED Red Green Blue Amber and White Lifetime Long 100 000 hrs 60 degradation DMX512 In Out with XLR 5PIN RGB max 60W RGBAW max 100W Power Connection 100 260V AC In Out PowerCon Net weight 6kg Dimensions