CID-Pro 4.00 User Manual
Contents
1. Delete user Mark the names of the users to be deleted in the list and click the Delete button Your entry will be subsequently checked with the following confirmation prompt ab Warning Se Do you really want to delete user cts The user to be deleted here cts will be redisplayed With Yes the user is finally deleted with No the deletion function is ignored Take note Deleted users are irrevocably lost User Manual for CID PRO 4 02 49 Section4 Program parts and functions Insert user You add a new user with the Insert button Hereupon a window opens that you can supply with the user name password and repeat password timed logout units assignments and privileges a time dependend loggout Loggout after min x D Rights apply to all test units F Selection Rights apply only to selected units Rights Open editor Editor changes Open graphic Start Stop unit Start programs Switch digital channels Open configuration Change set values Open counter Interrupt Programs Change recording Contin errors Open reports Lock unlock test unit control Use report functions Bat CID a a a a a a a a a With OK the settings and therewith the new user are accepted With Cancel new user creation is ignored 50 CID PRO 4 02 User Manual Section4 Pro
2. 108 CID PRO 4 02 _ Display Temperature Set Act Humidity Set Act Setting Name Temper Humidity Display Temperature Set Act Humidity Set Act Watertank Set Act Temperin Set Act Setting Name Default Setting the first 4 analogue and digital channels were selected gt default values User Manual 4 Setting Test 1234 Section4 Program parts and functions ET 09 08 14 72 45 2108 Display HV TemperOut Set Act Humiditylnlet Set Act HumidityOut Set Act sang mm 180079 2108 4 other digital channels as the standard setting Setting Name Test 1234 Characteristics of the setting displays Take note User Manual New Setting in the Settings menu is used to create a new setting Delete Setting in the Settings menu is used to delete the setting currently displayed By clicking on a setting number e g 4 O in the setting menu or in the toolbar O this setting will is be loaded gt A defined setting is displayed in the menu in regular font and where applicable the setting name is displayed The symbol is displayed in the toolbar gt A non defined settings is displayed in the menu dimmed and cannot be selected This setting is not available in the toolbar cf the Setting 3 examples shown here gt The selected setting is ticked in the menu and displayed red in the toolbar IS C CID PRO 4 00ymessung C 70 350 m01
3. Select program Create program The unit is symbolically represented in the left area The arrow icon shows the cradle position here on top The cradle s temperature is given below as long as your shock test cabinet has a cradle sensor external PT100 If the shock test cabinet does not have a cradle sensor the cradle temperature is shown as the warm chamber temperature when the cradle is located in the upper chamber and as the cold chamber temperature when the cradle is located in the lower chamber Cradle temperature data then appears as follows Warm chamber upper chamber W 100 0 C Cold chamber lower chamber C 61 9 C The current actual values are shown to the right next to the unit e Remaining cradle delay time in the warm chamber above and its actual temperature gt red fields Already completed cycles gt grey field Actual cold chamber temperature below and remaining cradle delay time in this zone gt blue fields User Manual for CID PRO 4 02 143 Section4 Program parts and functions Program data are shown in the area to the right This is the program name and number program location in the controller as well as a graphical presentation of the test cycle with the programmed benchmark values pre temperature temperature hot chamber hot chamber difference 12 K s cl T 7 LU TT TT Ib temperature pre temperature cold chamber pl i cold chamber difference e Temperature wa
4. 0 i 2 3 4 5 6 7 8 9 10 se User Manual for CID Pro 4 02 89 Section4 Program parts and functions Fullscreen AY Return from any arbitrary zoom level to the overall view full screen Zoom out Zoom outa level shrink Zoom Kei Zoom in a level enlarge assuming you ve already defined this level If not then the function or button is greyed out That way you can always identify how far you have already zoomed Take note You can only zoom with precision on one object That means for example on 1 minute and 1 C exactly The method of dragging the desired area with the mouse was explained in this instruction manual based on the upper left to lower right corner You can carry out this function in an arbitrary direction The zoom area is depicted during zooming by a dashed rectangle This enables the area to be defined better 90 CID PRO 4 02 User Manual Section4 Program parts and functions 4 5 Graphical measurement data analysis 4 5 1 Preface In the graphical view you have the option to graphically present and analyze acquired measurements When starting graphical measurement data analysis a pop up window for loading a measurement or the active record opens Je e 1 SS RS SS SE F I j an r k p erc E y H p b s KO I Im Wirit No i ine Vague pr Lal PETE este F et Tere een 0S SS ORD JL LI d End Pete
5. to Time Calculation po Ee Ba E Save file in data pool Save File in Data pool Ctrl F cf sec 4 4 4 15 p 86 d Save file as library Gel Save File as Library cf sec 4 4 4 16 p 86 e Delete Templates and Ki Delete Template s Library ies Po Comment Comment editor 156 Zoom functions g IG CID PRO 4 02 cf sec 4 4 4 17 p 87 Zoom functions editor cf sec 4 4 4 18 p 88 User Manual Section 6 Buttons of the CID Pro 4 02 software 6 3 Graphical measurement data analysis Menus Symbol File Fa x a Ve 3 Zoom I e A View Extra D B Settings U 2 Q QO Q v Q vw 10 Help Comment User Manual Submenus Open Delete Print Print as PDF Files last opened Exit Complete Frame Restore Zoom Out Zoom Zoom to cursor positions Display Analysis Options Convert to Excel Program Display Measure ment Value completely cursor position Copy to Clipboard Join Measurement Files Cut current Measurement File Cursor Setting 1 Setting 2 Setting 3 Setting 4 Setting 5 Setting 6 Setting 7 Setting 8 Setting 9 Setting 10 New Setting Delete Setting Help for CID PRO 4 02 Also in toolbar X X X X gt lt x XD KK KK X XD KM KR KR KR KK o Key combi nation Ctrl 0 Ctrl D Ctrl P Ctrl F Ctrl E Ctrl R Ctrl U Ctrl Z Ctrl S Ctrl I Ctrl A Ctrl T Ctrl X Ctrl C Ctrl M F1 Reference
6. Click the closed lock symbol and you can logon yourself with user name and password f a IS CID user logon den Password o User logoff E gt gt E Click on the open lock symbol and the mode switches automatically to locked operation mode User Manual for CID PRO 4 02 53 Section4 Program parts and functions 4 2 7 PDF Settings In the PDF settings the RT TELET following options may be selected open immediately Check this box to select whether the PDF files created and saved in the various CID PRO Open PDF file immediately after saving menus are to be opened immediately 54 CID PRO 4 02 User Manual 4 3 Overview of all test units Section4 Program parts and functions Here you receive clear information about the state of all displayed test units The information can be viewed but not changed 12 Overview ve mesm Unit Unit Name Type Climate Cabinet C7032350 C 70 350 Programname g set U01 u02 Temperature Cz T40600 U03 n Temperat U04 740600 U05 1st Channel 1st Channel 2nd Channe 2nd Channe 3rd Channel 3rd Channel remaining 00 zyklus C_70_350 201 No 1 167P Temper Temper T 40 600 ManualMode nn 262C 0 30 ka pr Le hot Te ey ei cage Ter cage 15570130 ege e 75222 Soe se KE act set act set act prog time 4 days 08h 47m e Teneo E IT 20 0 Che Temper pose ar W Te W a
7. Temper Gradient to takes the Y coordinate over into the calculation Rise of line 5 The temporal distance is calculated with the help of the gradient and the value e g temperature entered and this A point is then created in the editor Temper 100 00 amp Back Gradient E 25 K min for CID PRO 4 02 85 Section4 Program parts and functions 4 4 4 15 Save file in data pool The data pool denotes a virtual area in which globally valid test programs are saved In other words you create a test program that you want to run on several identical test units This virtual area distinguishes itself from the normal program by its extension Data pool programs end with Pxx for example P01 Normal programs end Zxx for example Z01 These data pool programs are manageable like normal programs When opening the data pool program you must be sure to click on the data type all files then select and open the right file The big advantage of these data pool programs consists of the fact that you can select not just normal programs during automatic start up but also a data pool program that originated from a different test unit When loading a data pool program the program s configuration is compared with that of the test unit on which the program is loaded If the channels agree the data pool program can be loaded If the configurations fail to agree on the most important properties transfer is prevented Plea
8. The following jump record is displayed following the marked line after confirmation with OK Jump Line 15 J You see a vertical dark green line on the graph as a check indicating conditional jump Take note The jump function is active during the entire run time of the line following the jump function This way not just a single query is possible but a sort of interrupt operation The displayed loop count and level are no longer correct if the jumping function is used within a loop and the jumping target is outside of the loop 76 CID PRO 4 02 User Manual 4 4 4 11 Insert Program lf a module program should be inserted the module program must always be generated first and subsequently the main program To enter a module program use the left mouse button to activate the line which should be inserted after the insert program Click on the insert program 3 button or press F10 to display the window to insert a module program You can use this menu to select the file name of the module program In addition when selecting the program number the module program is allocated a place in the controller When the main program is sent the module program is transferred to this place in the program The main program and each module program used must be assigned a dedicated program number Only one module program can ever run in a main program The status display in automatic mode displays both the main program and the module p
9. e Entries for temperatures pretemperings delay times and cycle number are the set values of the test program e Wait for zone temperature after program start is inserted by check marking a wait function in the program The program waits until the warm chamber has reached its set temperature with a tolerance of 3K before beginning the first cycle e Wait function activate upper PT100 inserts a wait function for each cold warm cycle when check marked Delay time in the warm chamber only begins to elapse when the tolerance range here 3K entered for the warm chamber s temperature sensors is entered The temperature must approach the zone from below e Wait function above free PT100 inserts a wait function for each cold warm cycle when check marked Delay time in the warm chamber only begins to elapse when the tolerance range here 3K entered for the free PT100 temperature sensors option is entered The temperature must approach the zone from below User Manual for CID PrRo 4 02 147 Section4 Program parts and functions e Wait function activate lower PT100 inserts a wait function for each warm cold cycle when check marked Delay time in the cold chamber only begins to elapse when the tolerance range here 3K entered for the cold chamber s temperature sensor is entered The temperature must approach the zone from above e Wait function below free PT100 inserts a wait function for each warm cold cycle when check marked Delay time in the
10. 43 3 C The following information is displayed Self defined Unit Name units commission number Unit Type Mode Program name First 3 analog channels Remaining Prog time Start status Error status To better distinguish the units the self defined meaningful unit name and unique commission number are shown Unit s type from unt e controller Manual Mode Manual Mode entry Program Mode test program entry with complete path Display of set and actual values of the first three analogue channels If only two chan nels are present the third channel s set and actual values field is empty Manual Mode Program Mode test program s remaining runtime green unit started orange unit started Pause l unit stopped white no communication with the unit green no error red ERROR with display of the an Warning error number With the Back button you return to the status overview display Take note With more then 12 units the window can be enlarged from top to bottom User Manual for CID Pro 4 02 55 Section4 Program parts and functions 56 CID PRO 4 02 User Manual Section4 Program parts and functions 4 4 Test cycle program editor 4 4 1 Preface If you open the editor you will find yourself in New test program and can get started immediately Now the editor s layout can certainly differ somewhat depending on which unit you want to create the t
11. Open and load measurement cf sec 4 5 3 1 p 93 Delete measurement cf sec 4 5 3 3 p 95 Print measurement cf sec 4 5 3 4 p 96 Print measurement as PDF cf sec 4 5 3 5 p 96 Open and load measurement 4 5 3 1 Exit the graphical measurement data analysis Zoom functions graphical measurement data analysis cf sec 4 5 3 6 p 97 Display cf sec 4 5 3 7 p 99 Analysis cf sec 4 5 3 8 p 99 Options graphical measurement data analysis cf sec 4 5 3 9 p 100 Excel conversion program cf sec 4 5 3 10 p 103 Display Measurement Values cf sec 4 5 3 11 p 106 Copy to clipboard cf sec 4 5 3 12 p 106 Merge measurement files cf sec 4 5 3 13 p 107 Cut current Measurement File Cursor cf sec 4 5 3 14 p 107 Settings cf sec 4 5 3 15 p 108 Comment graphical measurement data analysis cf sec 4 5 3 16 p 110 157 Section 6 Buttons of the CID Pro 4 02 software 6 4 Event logs Menus Symbol File a J 0 Error list Power fail E Mail message Extras ES Help EA 6 5 Visualization Menus Symbol Close Extra Units 158 Submenus New Load Delete List Print kk completely List 4 completely as PDF List filtered POF H List sa filtered as PDF List Export completely List filtered Exit Options Help Submenus Configuration Load Settings Save Settings Reset Settings Units CID PRO 4 02 Key combi nation Ctrl N Ctrl L
12. y every x 7 days around 13 00 Y hours minutes 5 by the minute Next storage date at 14 09 2010 around 13 00 00 05 10 15 Time interval weekly Weekday Sun Sat Record options Week day by the hour Hours Minutes weekly always on x Monday around 13 00 v hours minutes 5 by the minute Next storage date at 13 09 2010 around 13 00 00 05 10 15 Ero 01 28 of the month en om Day of the month by the hour monthly onthe 01 Y of each month around 13 e e ed hours minutes 5 by the minute Next storage date at 01 10 2010 around 13 00 00 05 10 15 If you change the interval and the parameters associated with it the next storage date will be immediately updated Configure into the file format how automatically created measurement files should be identified Text Date in the format vn mm dd bi mm sei Date in the format yyyy mm dd hh mm ss gt year 4 place month 2 place day 2 place hour 2 place minute 2 place seconds 2 place Text Date in the format yyyy mm dd hh mm ss stored measurement file C C ID PRO 4 00 messung Test SensorA m01 automatic file 1 C CID PRO 4 00 messung Test SensorA_2010 08 26 14 30 00 m01 automatic file 2 C CID PRO 4 00 messung Test SensorA_2010 08 26 15 30 00 m01 In the process the measurement values are always stored in the original measurement file here Test SensorA m01 This is renamed with the storage time here to Test SensorA_
13. 4 1 1 Jeq nuow pue OQU S TL 19 for CID PRO 4 02 User Manual Section4 Program parts and functions 4 1 2 Symbol and menu bar Main symbol and menu bar functions are listed in the following Exit Functions Help raje Visualization Ctrl Sie All Test Units Ctrl 0 Editor Ctrl E i Graphic Ctrl G Automatic Mode Ctrl A Measured Value Recording Ctrl M Contiguration Settings Ctri Counter Ctrl C Reports Log Files Ctrl R Exit Visualization section 4 10 page 137 Display your test units in a self generated environment Overview of all test units section 4 3 page 55 Display all your connected test units in a overview Test cycle program editor section 4 4 page 57 Create edit change and delete your test cycle programs Graphical measurement data analysis section 4 5 page 91 Display your test data in a diagram and analyze them Starting test programs automatic section 4 6 page 111 Start a test cycle program from CID PRO 4 02 in automatic mode Manual measurement recording section 4 7 page 117 Document the progress of analogous and digital channels test units with test value records Configuration CID Pro 4 02 Settings section 4 2 page 35 Configure your software according your requirements Operating hours and event counter section 4 8 page 123 Display your operating hours and events Event logs reports section 4 9 page 125 All
14. 4 5 3 10 Excel conversion program page 103 5 The recording settings are accepted with OK and discarded with Back User Manual for CID Pro 4 02 113 Section4 Program parts and functions 4 6 3 Start options After program transmission it is possible to enter a Starting time and date and a Offset for the program Program Start Program Offset Starting time 11 58 Line No Starting date 07 05 2010 Program Start Starting time and date are entered via the keyboard In this connection any arbitrary admissible date within a year can be entered The time must conform to the hh mm hour minute format The entry is ignored if the prescribed formats are not adhered to If a time is entered prior to the current time having thus already passed the current clock time is assumed gt so first change the date then the clock time The current date is assumed if an incorrect date is entered Take note Check the current system date Program Offset The Line No field defines the start line and serves to skip over the beginning of the program The range within which the entry can lie is given to the right of the starting line field and depends on the length of the selected program in this case 0 66 The information in the Offset field changes with the entry of a starting line Here the time to be skipped is calculated Loop iterations and wait functions are not taken into consideration during the calculation Th
15. Enter the current password into the Actual password text field If the password is correct you can enter a new password You must re enter your password to ensure that you haven t mistyped The new password is accepted only when both entries are identical You deactivate simple password protection with a click on the Deactivate password security function and subsequent entry of the correct password in the confirmation prompt Take note Simple password activation deactivation acceptance occurs immediately and requires no additional storage To accept mode change from simple password to access configuration and visa versa the setting must be stored with the save settings button and GID PRo 4 02 software must be restarted User Manual for CID Pro 4 02 47 Section4 Program parts and functions 4 2 6 2 Access Configuration Settings User administration allows and J Configuration requires creation of users with appropriate privileges for individual program parts A user logon is always required then Changes can be assigned to a user Access Configuration simple password Take note JSeMame w Access Configuration CID PRO 4 02 software must be restarted after selecting access configuration so that the settings can be accepted The list of user names presented here shows all established users The second column shows whether the user possesses administrative privileges Only users with administrative
16. File Zoom View Extra Settings Help Comment FX Setting 1 Temper Humidity X 3 Setting 2 Default Setting 210 00 A Setting 3 Di Ai v Setting 4 Test 1234 ER Setting5 CDN settings FRE Setting KR settings 180 00 9 Setting 9 HU Setting 10 a New Setting Delete Setting l 110 mn l new setting is always placed in the next available storage location gt Setting 3 is created The setting name can be freely selected in Options and will be reproduced when the title bar is selected All settings directly relate to the selected loaded file It is not possible to load another file for each setting for CID PRO 4 02 109 Section4 Program parts and functions 4 5 3 16 Comments graphical measurement data analysis Comments belonging to the measurement open that you can arbitrarily change here All text editor functions are possible here Sak Comment Comment forthe amp 70 350m01 Take note Maximum comment length 255 characters 110 CID PRO 4 02 User Manual Section4 Program parts and functions 4 6 Starting test programs automatic Starting test programs produces automatic operation In the process the compiled test programs are transmitted to the selected test unit Program Unit Prog no Program Name Program Start Program Offset Starting date 4 6 1 Selection the test cycle program Choose the desired Unit No to which the test program should be sent
17. Gradient to Time Calculation Save File in Data pool Save File as Library Delete Template s Library ies Zoom functions for CID PRO 4 02 Print Graphic Print Both Print Screen Print Graphic as PDF Print List as PDF Print Screen as PDF With Valued Calculation Also in tool bar lt x XD e lt x KC KM KR e lt x XX WK KR KK Key combina tion Ctrl N Ctrl 0 Ctrl S Ctrl A Ctrl 1 Ctrl G Ctrl L Ctrl B Ctrl T Ctrl E Ins Del Ctrl X Ctrl C Ctrl V F6 F7 F2 F3 F4 F5 F10 F11 Ctrl P Ctrl D F8 F9 Ctrl F Section4 Program parts and functions Reference New test program cf sec 4 4 4 1 p 69 Open test program cf sec 4 4 4 2 p 69 Save as test program cf sec 4 4 4 3 p 70 Printer page setup and print cf sec 4 4 4 5 p 71 Print as PDF cf sec 4 4 4 6 p 72 Open test program 4 4 4 2 Exit the editor Edit lines insert change delete cut and copy with keyboard menu functions cf sec 4 4 3 1 p 60 Block of lines cf sec 4 4 4 7 p 72 Loop loop beginning and end cf sec 4 4 4 8 p 74 Call Subprogram cf sec 4 4 4 9 p 75 Conditional jump cf sec 4 4 4 10 p 76 Insert Program cf sec 4 4 4 11 p 77 Refresh the editor Templates cf sec 4 4 4 12 p 78 Options editor cf sec 4 4 4 13 p 79 Delete test program cf sec 4 4 4 4 p 70 Set Gradient cf sec 4 4 4 14 p 82 Save f
18. chamber The temperature in the chamber sinks e The thin reference line in the lower half of the schematic illustration represents the temperature development of the cooling chamber It varies within a range from approx 22 C to approx 5 C The different values have the following meanings 10 C Target temperature current temperature of the cooling chamber with the cradle 22 10 C 12K target value entered pretempering 5C Temperature shortly after the warm cradle has entered into the cooling chamber The temperature in the chamber rises Notice The pretempering should if possible be selected in such a way that the alteration of temp in this case 45 C or 5 C during the appearance of the cradle into the respective chamber corresponds to the temperature target value Additional screens are called up with the buttons cf sec 4 11 1 3 Program Create program start page 146 and cf sec 4 11 1 4 Test program creation page 147 User Manual for CID PRO 4 02 145 Section4 Program parts and functions 4 11 1 3 Program start The 22ect program button opens a window for selecting program name and number 312 select program The unit controller has available program locations 1 to 97 The test program is stored in the controller at the program location chosen here Only the programs from the program cycles shock test default directory are selectable This subdirectory is named as f
19. changes closes the window E Selection Time changed this way in the list is always the line s run time These run times are lined up on the graph for the complete test cycle oftware limit max 130 0 min 20 0 Digital values can be changed or negated with the Enter key if the desired field is selected or by double clicking the left mouse button on the desired field This updates the graph bar display in the lower area Vait function Activate z 15 CID PRO 4 02 User Manual Section4 Program parts and functions A window with the corresponding values opens when changing a loop subprogram or conditional jump line You can then change values like the number of loop interactions when starting a loop 3 Edit multiple lines Time Temper Humidity deepdeh Dig outp lt in E D1 D2 Indicate the fields which you want to set to the same value Use the Enter button to open a window The indicated fields can be edited here Take note 4 Delete lines j3 Selection ni t in C in r Only multiple value lines can be edited If there is a no value line e g loop start in the indicated range the action is interrupted That means after pressing the Enter button the window does NOT open Thus a digital channel can be edited With the Del key or the E symbol the currently active line is deleted from the list and thus from the
20. sec 4 5 3 10 Excel conversion program page 103 User Manual for CID PRO 4 02 117 Section4 Program parts and functions Enter a file in a file selection window with the save as button into which the measurements should be stored This selection is necessary so that the recording can be started If you want to append a measurement to an already existing file Select the existing file Confirm that this is the file you want to replace or overwrite Confirm Save As C 70 350 mOl already exists Do you want to replace it Choose YES to append the new measurement to the already existing file or NO to permanently overwrite the selected existing file rs CS Attach measuring to existing file or overwrite the existing file Yes Attach measuring No OVERWRITE A comment window will appear in which you can describe a measurement in more detail or enter special remarks if you have selected an already existing or new measurement file 312 Recording of U01 Climate Cabinet Start options Record options G Stat now Recording all seconds d 60 0 1 r r Lyle storage Cyclic storage Times A h Date fe adivate GA Recording of the Program L 70 350 201 Back STOP 118 CID PRO 4 02 User Manual Section4 Program parts and functions Start options Start at Besides the immediate recording start the delayed start can also be activated Start time and date are entered via the
21. 2010 09 02 16 41 19 m01 CID Messung 2010 08 02 17 04 20m01 selected file gt AC 70 350m01 You must successively enter new file names for all selected files It is not necessary to append a file extension because the conversion program independently appends csv the usual Microsoft Excel extension Conversion which can last a few minutes depending on file size begins after correct entry of the respective new file names All existing data lines i e all currently selected analogue and digital channel measurement values are converted Now you can read the converted files generated into Microsoft Excel or even another spreadsheet program To this when opening the file saved in text format you can further define Open spreadsheet calculation Select and open the desired file with File Open Start the Text Import Wizard Test men gend Zeie kl Test l e Wand Step dat l KSC Tet kreeg Weg Sat Fet l EA The Taat irad f r Deomed ar pour ein a M kA Abbes ETI pei ioe S T ETE your RER sn ne Feu Til porn ed suter ard sek Wan Ee E Select data type Delimited Semicolon as Possibly adjust delimiter column data format Finish Text Import Wizard Microsoft Excel Help further describes the importation of text formatted files and should be able to help you with further problems 104 CID PRO 4 02 User Manual Take note Section4 Program parts and functions The file created by the conversion program
22. 3 Unit number Test Unit 01 unit name Climate Cabinet commission number C70350 unit type C 70 350 analogue channels and digital channels Softkeys and indicators The LED in the upper right turns red when there is an error at this test unit The entire window turns green when the test unit is started If a program is running in program mode its path is displayed 138 CID PRO 4 02 U04 Temperature C White frame Test unit doesn t answer Gray frame Test unit connected not started Green frame Test unit connected in operation Orange frame Test unit connected in operation Pause Red frame Test unit connected error present Yellow frame Test unit connected warning present No representation Test unit not configured User Manual Section4 Program parts and functions 4 10 4 Visualization functions 4 10 4 1 Configure setting You can make changes to the display in the visualization configuration 2 Configuration Window Size width x height width height user defined wl 1050 CH 700 Background Image CACID PFRO 4 OTwisuallFaimlan Electronica jpg Climate Cabinet Test Unit 01 Unit No S S CACID PRO 4 O0 wisual C 70 Ain jpg Fj Retain aspect ratio Window Size width x height user defined You can select window sizes from the adjacent specifications 300x 225 For example If you select a fixed size of 800 x 400 pixels the 400 x 300 v
23. Ctrl Del Ctrl C Ctrl F Ctrl E Ctrl 0 F1 Key combi nation Ctrl C Ctrl L Ctrl S Ctrl R Reference New report cf sec 4 9 3 1 p 127 Load report cf sec 4 9 3 2 p 127 Delete report cf sec 4 9 3 3 p 127 Print report cf sec 4 9 3 4 p 128 Export report cf sec 4 9 3 5 p 128 Exit the event logs Error list cf sec 4 9 3 6 p 129 Power fail cf sec 4 9 3 7 p 131 E Mail message cf sec 4 9 3 8 p 132 Options event logs cf sec 4 9 3 9 p 135 Reference Exit visualization Configure setting cf sec 4 10 4 1 p 139 Load setting cf sec 4 10 4 3 p 142 Save setting cf sec 4 10 4 2 p 141 Reset setting cf sec 4 10 4 4 p 142 Test unit display cf sec 4 10 4 5 p 142 User Manual Section A End user license agreement 8 End user license agreement 8 1 Copyright memo CTS GmbH is not liable for technical or printing errors or defect in this manual and also accepts no liability for damages which are caused directly or indirectly by the supplier performance and usage of this material This document contains information protected by copyright which are subject to copyright law All rights are reserved This document may neither be copied nor otherwise reproduced either completely or in excerpts without the previous approval of CTS GmbH The software described in this document is subject to a license agreement Usage and reproduction is only permitted in
24. Dig outp1 D 50 0 D3 Dig outp2 0 60 0 Time 90 0 min S Temper 0 0 C Temper constant 80 0 i i i i 1 Humidty 0 0 H Humidity constant 0 250 500 750 1000 1250 1500 1750 2000 2250 2500 2750 3000 3250 3500 3750 4000 4250 4500 4910 t min deep dehu esse Dig outp 1 Dig outp2 Statement of all important line information at a glance Line 36 1860 0 min Time t min 120 Temper in C 10 00 D1 deep dehu 0 Humidity in rH 70 00 D2 Dig outp 1 Oo D3 Dig outp IW Time 60 0 min Temper 30 0 t ramp 0 50 K min Humidity 10 0 rH ramp 0 17 H min Line number and time Analogue and digital channels with wait function if available e Relationship to next line ramp with gradient constant distribution or jump with statement of X and Y axis segments time and temperature humidity difference 58 CID PRO 4 02 User Manual 4 4 2 Buttons Menus File Edit Symbol b POF ys Moie BOY OOs Templates Extras Comm oe d lt T et gt KEM ent User Manual Submenus New Open Save Save As Printer Page install Print Print List Print as PDF vi R LE Files last opened Exit Insert Line Delete Line Cut Line Copy Line Paste Line Block copy insert Block delete Insert Start of Loop Insert End of Loop Call Subprogram Insert Conditional Jump Insert Program Refresh Templates Options Delete Program
25. E Mail message 132 Error MISTO E 130 ET 129 LETE Me 127 New report 127 New send configuration 00 00000 133 6 9 110 E 135 OW OF Men 131 Be 125 PU TEPON brosession 128 Send liSt E 132 SMTP SENE vm 132 Graphical measurement data analysis NE E EE 91 ACUVE OCOT NE 94 Analogue channel 101 Ve EE EN 99 PU Sa 92 Elus 100 CommenSu uasasaunamssmsunai 110 Copy to clipboard rrrrnrrnrnnnrnnnnernnn 106 CO SOP eege 95 Cursor visible rrrrnrernrrrnarerrnnenanennn 102 Cut current Measurement File 107 Pee 100 Default values rrnnrnnnnnnrnnnrnnnnnnnner 101 Delete measurement 95 Digital channel 100 BET 0 VE 99 102 Display Measurement Values 106 EVGIUATOM rusii 102 Excel conversion program 103 119 La fe UE 102 Merge measurement files 107 Open and load measurement 93 PHON S ached ctsccateediadsiprtsateicatesenciqunes 100 SE EEE 91 Print measurement rarannnnnnnrnnnnnnnnn 96 Print measurement as PDF 96 Right scale rrarnnnrnnnnnnnrrnrnnrnnnnnnnnn 101 Searching for a measurement file 94 TS INOS EEE 108 Show Heal fme 102 Show the evaluation analysis 102 Show the small Display 102 Working with graphical measurem 95 ZOOM TUNGUONS ae 97 STAN ALON siasvusievsessaewssesesvenssivesenienaneunien 8 PS GUO e ele E 13 Full network and demo version 10 163 S
26. Pro START 4 01 004 2 Full version TCP connection to test unit 2 OH adr 192 168 1 208 established TCP connection to test unit 3 IP adr 192 168 1 205 established CID Start Test unit is still running CID Start Cycle No 1 CACID PRO 4 MMayklusC 70 350 201 still punning Elapsed time 00 04 Measure file c CID PRO 00 messung C_ 0_350 m01 with 60 sec interval continued after CID CID user accounts not active No connection to test unit Waming install compressed air 10 B63 Digital channel Dig outp1 set to V by CID When you open the report menu the current report file is always automatically opened You will see all actions which have been recorded together with the settings which you made with the options cf sec 4 9 3 9 Options event log page 135 All actions are filed in a file which is issued new every month The date of creation can be seen from the filename In this example the file was created on 01 09 2010 CID installation path report 20100901 REP Please note From version 4 of GID PRoO software onwards the report files are saved in the following format yyyymmdd rep gt Year 4 digit Month 2 digit Day 2 digit rep This allows them in the system to be considerably better filed and enables searches for particular dates User Manual for CID Pro 4 02 125 Section4 Program parts and functions lt can happen that the entries in the list are so long that they are not completely readable Left clic
27. SEN Pr e on ES ENE a Take note The states are only changed when the active test unit confirms this change If your unit configuration contains more than eight Softkeys or marker channels the digital channel screen adds two paging symbols and which enable back and forth paging of the digital channels gt 30 CID PRO 4 02 User Manual Section4 Program parts and functions 4 1 10 Analogues channels The display of the analogues channel relates to the currently displayed test unit Channels are displayed dynamically depending on unit configuration like how many analogue channels this unit possesses Only the analogue channels actually present in the controller and activated for viewing are shown on the display The various analogue channels are represented as follows Analog Channels Set Act Representation Symbol Channel Unit Zeng in C S P Temperature 75 00 43 49 red d CH channels C Humidity i in rH ah D Humidity S ee se blue 1 channels ii Channels Watertank in green with water I liter information w eg informati Other e green sn arbitrary The actual analogue values on the right are represented with weaker colour intensity than the set analogue values In contrast to the actual values in manual operation these can be arbitrarily changed In program operation such a change is not possible because the program permanently presets the values Changing a set value
28. Show preview editable Do you want no preview before printing or do you want to show the list first in the preview The preview is editable i e it can be changed in the window e Use your own address The list contains a file header containing JE Print Options Expression at printer selected finally Default Printer S JE Print Options Graphic List Generally Print Format Landscape dl Indicate Preview changeable Address Use own address ces the CTS address crs Gab Aa If you want to give your own address check mark the box next to 72978 Hechingen o Use own address and complete the address data company Fax 49 0 7471 9850 23 street location telephone fax and internet C CID PRO 4 00 zyklus C_70_350 Z01 You can also label the fields in accordance Wi SES written on 01 09 2010 requirements 2 Print graph Di After selecting this function you will be shown the printer selection depending on options setting cf point 1 Printer page setup graph the graph will be output on the selected printer or your default printer User Manual for CID PRO 4 02 71 Section4 Program parts and functions 3 Print list This function prints the values list out on the default printer Depending on print options you can control this print cf point 1 Printer page setup graph 4 Print both graph and list Ea Select this men
29. The next time the editor is opened thereby creating a new program this program appears as an entry in the Templates menu The clib is missing and is not shown because this entry is unit independent and should consequently be shown for every configuration and unit IS Test Unit 1 NewProgram Z01 File Edit Templates Extra Help Comment P LIEC 68 3 30 Modul 1 IEC 68 2 30 201 4 The test cycle editor opens when you click on the entry Confirmation prompts concerning changes to an already edited new program are displayed first The program is now opened as C CID PRO 4 00 zyklus IEC 68 2 30 Modul Z01 selected with test unit 1 5 Modify this open program to meet your current requirements Take note If you store a program in a different unit s library the channels will be adjusted following a confirmation prompt 4 4 4 17 Editor comments An input window opens in which a one to 250 character long commentary about the current test cycle program can be entered You select OK to save the entries in the input window or Cancel to close the window without accepting the changes Comments about a currently running program can be called up in the status overview in the program automatic cf sec 4 1 6 Program automatic page 26 Moreover the comments are also output when printing the test program only in the list User Manual for CID PRO 4 02 87 Section4 Program parts and functions 4 4 4 18 Editor zoom
30. The number under which the program is stored in the controller is defined under Unit Prog No The program type selection here Test Unit 1 indicates whether a unit program like unit 1 z01 can be selected or a program from the data pool meaning all P programs The adjacent text on the right here z01 shows which kind of program may be selected Program Unit Prog no Program Name Program Name shows the desired program that was selected with the button in the file selection window Send transmits test program data but only if a program was selected User Manual for GiID PrRo 4 02 111 Section4 Program parts and functions 4 6 2 Recording the test cycle program You have the option of starting a test program recording Execution Please proceed as follows to activate the recording 1 Clicking on Recorder opens the following window JE Recording of Climate Cabinet Test Unit 01 Comment Recording Back save as 2 You give the measurement file a name by selecting a file with save as in the following 112 file save window or creating a new file and confirming with save lf you want to append a measurement to an already existing file Select the existing file Confirm that this is the file you want to replace or overwrite eat PH Ge As C 70 350 mOl already exists Do you want to replace it Choose YES to append the new measurement to the already existing fil
31. calculated values are more or less equal For major changes in the curve the calculated values are inaccurate from the start for CID PRO 4 02 105 Section4 Program parts and functions 4 5 3 11 Display Measurement Values This function displays the data records of the loaded measurement file in a separate window In this display the data records are listed with the following information exact time information date and time e all analogue channels set and actual value down to 4 decimal places e all digital channels actual value e Number of listed data records entries in the window s header here 2842 entries Tenpzul Acct Wasservor Wasservor Set Act Set Temper Act Date Tine E 1 KL 4 9918 0000 0000 2 6282 05709708 09 45 10 05709408 05709708 05709 08 05709708 05709 08 05709708 8 7804 11 3356 13 8356 19 2070 21 7702 24 1207 OO OO on on CO r A d gt 0000 H 8 H H 8 H g 0000 1 15 22 i 29 3L 3369 In this display the measured values can be compared and the ranges analysed exactly such as measured values between 1 p m and 2 p m of the same day Under completely the data records of the complete file are displayed cursor position the data records for times between the two cursors are displayed This function is only executed if the cursors are active In this case the start and end time of the cursors and or the order
32. chamber pretempering heating chamber DifffemHo and for the cooling chamber it is negative pretempering cooling chamber DifffemCo 144 CID PRO 4 02 User Manual Section4 Program parts and functions These variable pretemperings are analogue channels so that they can be optimized for the target values entered and particularly for the mass of the item to be tested Changes in the analogue channels cf sec 4 1 10 Analogues channels page 31 5 Pretempering Heating chamber S my EE SO of J Si em PE Fe BEE S gi Ot 2 EN SEE LEE SN TE GE SG NG Tx SS l 1 PV mm 2 ol EE o oon E ml hom tS o S LL S 20 emm Sg Sg KEE S pm Lag 7 ease S plis p ill 1 Cycle 20 min 20 min 140 min O 3 10 x 20 min 200 min m Pretempering Cooling chamber Comments regarding this diagram e The thick reference line which varies within the range of 60 C to 10 C represents the target temperature for the cradle e he thin reference line in the upper half of the schematic illustration represents the temperature development in the heating chamber It varies within a range from approximately 45 C to approx 72 The different values have the following meanings 60 Target temperature current temperature of the heating chamber with the cradle 72 60 C 12K target value entered pretempering 45 Temperature shortly after the cold cradle has entered into the heating
33. changes warnings and errors can be displayed and provided with comments Help Info Software information section 7 2 page 160 CID PRO 4 02 Exit Ctrl V Functions Ctrl O Functions Ctrl E Functions Ctrl G Functions Ctrl A Functions Ctrl M Functions Ctrl S Functions Ctrl C Functions Ctrl R Functions F1 Help Ctrl 1 Information User Manual Section4 Program parts and functions 4 1 3 Test Units The symbols give an overview of the current status of all test units set in the configuration See list below for a description of the colours Symbol Colour Configuration Test Unit x red X not configured not present Doesn t answer white configured Main switch off or No connection connected grey configured ren reen configured connec g in operation connected orange configured in operation Pause connected yellow configured red configured connec error Clicking on a symbol changes the status overview screen Test Units to display the selected test unit and show the current i values A Climate Cabinet VW Temperature Cabinet 1 The selected test unit respective the current test unit which a Gack Tet Cabinet is displayed is bolded in the list of all test units Temperature Cabinet 2 p planned Test Unit If you have entered more then 16 test units in the configuration you will get the two paging symbols and gt E With version 4 of th
34. cold chamber only begins to elapse when the tolerance range here 3K entered for the free PT100 temperature sensor option is entered The temperature must approach the zone from above Wait function use increases the test duration The waiting time depends on the set tolerance and the chamber s load If wait functions are not activated the test program s run time begins to elapse independently of the actual values in the chambers Save saves the set cycle under a freely selectable name Load can load edit modify and with resave an already created cycle or back it up under another name When the selection Start in cold zone is made the graphic display also changes Shock Test Editor Shock Test Editor Filer vanre irichi iais Filer warner g ckad dieelz ence nar baser melde krer PT IDO mene peer PT TOD mrk nors baser neste eege PT 100 aaia beaver PT IO Bihis ines ohare gt pen He TA T p Fi IBEERE 7 d Er 6 amp 8 D k 4 11 1 5 Manual and program operation For general standard temperature or climate test units manual operation is started by activating the start stop button in the status overview cf sec 4 1 5 Unit and error status page 23 If you start the shock test cabinet with this start stop button program operation i e the default shock test program starts by default in storage location 99 If you want to change this situation and start the shock test cabinet in
35. compressor and other components used In the bottom list the event counter is shown e g from solenoid valves or overpressure switch These count for example the valve switching cycles All counters are shown with the instantaneous value actual value its unit and the maximum value threshold which the counter may assume f CID PRO 4 02 receives a warning alert from the active test unit the associated line in the list is shown in red and a remark is appended sv bypass 0 0 d sv reinje 110 100 Limit 1 ME sv pre co 486 0 El If you are authorized to change the displayed counters you can open this window by double clicking or pressing the Enter key on the activated line The threshold and or actual values appear depending on which values you are able to change Confirm the modifications with OK and send the new values to the active unit You can ignore the changes with Back User Manual for CID PRO 4 02 123 Section4 Program parts and functions 124 CID PRO 4 02 User Manual Section4 Program parts and functions 4 9 Event logs reports 4 9 1 Preface The report function runs constantly in the background with CID PRO 4 02 software It records various user and test unit actions 2 2 CACID PRO 4 00 REPORT120100901 REP File Errorlist Powerfall E Mail message Extras Help Entries 854 854 13 09 10 13 09 10 13 09 10 13 09 10 13 09 10 13 09 10 13 09 10 13 09 10 13 09 10 13 09 10 13
36. containing this text in there names are displayed as results Subdirectory You can only search in this directory for the selected path or include all the subdirectories File name List containing all files found 7 Number of files found Search is started Load Read the measurement file and plot on the graph Search and Load windows are closed Back Search function cancellation 94 CID PRO 4 02 User Manual Section4 Program parts and functions 4 5 3 2 Working with graphical measurement data analysis Your analysis can begin when you have opened your measurement file Zoom Display a characteristic region of your measurement gt cf sec 0 Zoom functions Graphical measurement data analysis Analysis Analyze your curve progressions gt cf sec 4 5 3 8 Analysis Cursor Desired area can be either reached directly with the cursor or entered with the keyboard at the lower image border Both of the left number fields re late here to the left scale and both in the middle to the right scale The col ours match those of the cursor Cursor gt TT 1000 uF 667 06 09 08 2105355 22 Cursor2 gt TT on Fr 33 3 O7 0908 1543314154 Channel temperature Channel humidity Date Time in C in rH 4 5 3 3 Delete measurement You can select more several files at once here to remove no longer needed measurements E Delete esel Directory f Om Date mod gt 6064 i Recent Pa
37. digital channels e g number type name boundary values meters e g name limits operating hours regulators etc This configuration must be read in when you want to integrate a new test unit want to replace a test unit or for example want to assign a new address to a test unit This applies in general when system settings change at the test unit e g enhancement of a new sensor or when system settings change in the software e g other units numbers With the Configure Unit x function you can re read in the configuration for unit 1 for example The x stands for the unit number depending on which unit is selected After activating the function and the subsequent confirmation prompt the selected test unit s new configuration is requested Take note The selected test unit must be turned on for this Reading in a new configuration can take several minutes Configure all Test Units With the Configure Test Units function you can re read the configuration into all units After activating the function and the subsequent confirmation prompt the re configuration of all test units is requested You can find a complete description of the Configure Units function under Configure Unit x Take note All test units must be turned on for this Reading in all new configurations can take several minutes User Manual for CID Pro 4 02 39 Section4 Program parts and functions Only w
38. generated environment Overview of all test units section 4 3 page 55 Display all your connected test units in overview Test cycle program editor section 4 4 page 57 Create edit change and delete your test cycle programs Graphical measurement data analysis section 4 5 page 91 Display your test data in a diagram and analyze them Starting test programs automatic section 4 6 page 111 Start a test cycle program from CID PRO 4 02 in automatic mode Manual measurement recording section 4 7 page 117 Document the progress of analogous and digital channels test units with test value records Configuration CID Pro 4 02 Settings section 4 2 page 35 Configure your software to meet your needs Operating hours and event counter section 4 8 page 123 Display your operating hours and events Event logs reports section 4 9 page 125 All changes warnings and errors can be displayed and provided with comments Help Info Software information section 7 2 page 160 for CID PRO 4 02 Key combination Ctrl V Ctrl 0 Ctrl E Ctrl G Ctrl A Ctrl M Ctrl S Ctrl C Ctrl R F1 Ctrl l Reference Exit Functions Functions Functions Functions Functions Functions Functions Functions Functions Help Information 155 Section 6 Buttons of the CID Pro 4 02 software 6 2 Editor Also in Key Menus Symbol Submenus ool bar combina Referenc
39. graph For safety you are requested to confirm line deletion Take note 5 Copy lines With the Del key or the E symbol you can also delete entire blocks besides a marked line For example if you mark an arbitrary number of lines in the first column time you can completely delete these lines cf sec 4 4 4 7 Copy insert a block of lines delete a block of lines page 72 With the Ctr C key combination or the B symbol the currently active line is copied This line is now available for you to insert as a copied line cf point 7 Paste line copy Take note User Manual With the Ctrl C key combination or the B symbol you can also copy entire blocks besides a marked line For example if you mark an arbitrary number of lines in the first column time you can completely copy these lines cf sec 4 4 4 7 Copy insert a block of lines delete a block of lines page 72 for CID PRO 4 02 61 Section4 Program parts and functions 6 Cut lines With the Ctrl X key combination or the Ce symbol the currently active line is copied and removed from the list and graph For safety you are requested to confirm line cut This cut line is now available for you to insert as a copied line cf point 7 Paste line copy Take note With the Ctrl X key combination or the Ce symbol you can also cut entire blocks besides a marked line For example if you mark an arbitrary number of line
40. graph and plotting a point a value line is simultaneously created in the table showing the new point s values All points needed for the test cycle can now be successively plotted in the same way i e you plot one point after the other from a temporal perspective Since points are immediately connected you can only plot points in a free area of the graph toward the right If you want to plot a point between already existing points please refer to the procedure from point 3 Retroactively insert a values line A green cursor tracks during the creation of such a point showing you where you last Cursor timin 297 64 00 Lt clicked the graph or plotted a point This ed 14 95 1 67 min cursor orients itself to a grid that you can i i Time Temper Humidity deep deh Dig outp J define in the editor s options cf sec 4 4 4 13 nt ini 1 D2 Editor options page 79 0 0 If the cursor changes change parameters are shown in both dimensions Change time in minutes and hours 897 min and 14 95 hours Current channel value 64 0 C Gradient in unit min 1 67 K min CID PRO 4 02 User Manual Section4 Program parts and functions Up to now a point on the graph was defined with one analogue channel and time That s alright too if you have a unit with one channel If your unit has several controllable channels however you must have the option of changing this control channel Creation of red temperature po
41. gt unit 1 gt Z02 gt unit 2 etc User Manual for CID PRO 4 02 69 Section4 Program parts and functions 4 4 4 3 Save as test program You save your test program with this function A star is appended to the program s name in the title line if you changed something in your program That s the sign that your program needs to be saved e g when exiting the editor if that s what you want You now have two options Save B Save the test cycle program under the same name you opened it with For a new program gt save as Save as sc Save the test cycle program under a new name that you enter in the storage dialog You can also overwrite a previous file but Windows will ask you for confirmation test program can be copied by saving It several times with other names and or extensions That way it can also be made available to other test units Saved test programs are located in the Zyklus directory by default This directory can however also be switched Take note A test cycle program created for a particular unit like Z01 for unit 1 can be saved with a different extension for a different unit like Z02 for unit 2 lt should be observed in the process that the digital channels order as well as the analogue channels area must agree so that the test program works for the new unit An appropriate message appears in this case because a few adjustments have to be carried out in the background The p
42. into a file The function executes by means of selection dialogs and not via a separate window Extras Merge oo files Select and confirm first measurement file Select and confirm the measurement file to be Y appended to the end of ye first measurement file O OD Select and confirm the measurement file to be appended to the end of the resulting measurement file 2 OD Terminate the append loop with Cancel GA fa Select the name of the new or to be overwritten measurement file and save it Take note The measurement files structure will be investigated thereby insuring that only identical measurement files are merged A message will notify you of a non identical measurement file structure and this file will not be considered You can however select a measurement file 4 5 3 14 Cut current Measurement File Cursor If only a certain time range is necessary from a measurement file the loaded measurement file may be cut The two cursors are used to define the range to be saved as a cut file Proceed as follows Open the measurement file to be cut Mark the range with the two cursors Execute the function cut current measurement file Now the opened measurement file has been cut and saved in a new file with the appendix Cut Open the newly saved cut measurement file Name convention Original file C 70 350 m01 Cut file C 70 350 Cut m01 User Manual for CID PRO 4 02 107 Section4 Program parts and fu
43. list clearer The option coloured for error and warning messages indicates the errors as red and warnings as orange in the Report menu It can also be distinguished whether all units All or only a particular unit here unit 1 should be shown Furthermore you can provide the time range in which messages should be shown Observe the specified date and time format If you do not enter any values for stop time or date then all entries will be shown beginning with the start time and date up to the last entry Please note Depending on which messages have been commented on it is some times possible that no messages will be displayed any more The information about the number of current entries total entries in the report window gives you a rapid overview of how many messages have been commented on and how many messages are contained in the com plete report file Entries 650 854 The new settings become active after confirmation with OK These are saved and reused the next time the report menu is opened You can ignore the changes with Back User Manual for CID Pro 4 02 135 Section4 Program parts and functions 136 CiD Pro 4 02 User Manual 4 10 Visualization 4 10 1 Preface Section4 Program parts and functions With the new menu you have the potential to visually present your unit s Surroundings using background image and individual unit images User defined settings determine the size position and appearance of test u
44. max length 16 characters including file extension an error message Is displayed 19 Section4 Program parts and functions 4 4 4 10 Conditional jump Conditional jumps are program jumps resulting from digital input states The jumping function allows the test program to terminate or adapt in response to external evenis e To insert a conditional jump activate the line after which F one of the following the jumping function is to be inserted with the left mouse oe button Finally press the Jump function in the tool bar or the F5 key A window appears for the conditional jump The following line is temporarily displayed in the table EKEK DOLK Dom x The line to which the jumping function is to jump if the conditions are fulfilled is given next jump to Iine Select the desired line here As an aid the selected line _ in the table is displayed in blue and black IS conditional jump active jump if jump to line x 15 f one of the following expression is true active jump if You can select one or more channels as jumping conditions If several channels are activated they are joined with a logical OR Moreover the state of the respective channel can be defined To activate the temperature for example check mark the active box next to the channel on the left This activates the state and it is no longer greyed out You define the state by setting or resetting the button The Q or 1 state is displayed
45. not possible to develop EDP programs which are free of errors for all application conditions The manufacturer guarantees that the software is not defective during the statutory warranty period The software is considered defective if it does not fulfil the functions specified in the specification If such defects are present the manufacturer has the right to improve or redeliver on his own decision If during a suitable time limitation it is not possible for the manufacturer to rectify or bypass defects through supplementary performance the orderer allowing for statutory exceptional cases can on his choice demand a reduction of the licence fee or cancel the licence agreement if it is not possible for the orderer to use the software in accordance with the contract If only insignificant details are present the orderer only has the right to reduce the licence fee The above paragraphs contain concluding regulations with regard to the software warranty and exclude any other warranty claims CTS GmbH is only liable for damages which have not occurred to the article of sale itself only a in the case of intent b in the case of gross negligence from the statutory representative or management c in the case of culpable injuries to life body or health d in the case of defects which CTS has maliciously concealed or whose absence has been guaranteed by CTS e in the case of defects to the article of sale in so far as liability is presen
46. of the distance to the next raster line in each case Take note User Manual When you plot a new temperature point a new humidity point is also created if necessary Generally all other displayed channels receive a new point a complete values line in the list is created so that nothing in the gradient of the other channels changes The new humidity point was calculated and involves no changes in regard to the gradient of the former to the next humidity point The point is so to speak simply inserted As when inserting a value line with the mouse you must also select the right channel when changing the line otherwise you will plot a new point for a channel that you didn t want to create at all for CID PRO 4 02 67 Section4 Program parts and functions 4 Edit digital channels There is the possibility to edit the digital channels across multiple lines The channels Output1 and Output2 should be changed as follows 120 0 110 0 623 700 800 900 1000 1100 1200 1300 1400 1500 i 1700 1800 en 200 2100 2200 2288 s e min passnnenennsensensansnnenener d f 1 A double click on a phase directly sets this digital channel Dig outp 1 Dig outp2 deep dehu Dig outp 1 i Dig outp2 6 e 2 Mouse movement press and hold down the left mouse button at the start of the phase release at the end of the desired range E 3 4 Vesssalfesssesesseedfeesenet Take note The values in the table are automatic
47. privileges may create new users or delete or change existing users Change password There must therefore be at least one user with administrative privileges After the initial installation there is only one user Administrator with the password cid pro Take note Please pay attention to case upper lower case If you are logged on with administrative privileges you can use the Insert and Change buttons to determine user privileges or remove a user with Delete 48 CID PRO 4 02 User Manual Section4 Program parts and functions Administrator settings The administrator has full access That means that all privileges are checked for the administrator so that he has no limitations in regard to individual functions and the various test units e Sak User account Usemame Administrator Admin time dependend loggout Loggout after min x D Rights apply to all test units selection Rights apply only to selected units Rights Open editor Editor changes Open graphic Start Stop unit Start programs dl Switch digital channels Open configuration Change set values Open counter 4 Interrupt Programs Change recording dl Confirm errors Open reports dl Lock unlock test unit control Use report functions di Eat CID Furthermore he has the option of editing other users with the Admin function Ki
48. report Two options can be selected when printing a report a report file All entries in the report file complete list The function prints out the complete report file for you It contains all messages and comments The current list as displayed and filtered filtered list The function prints the report file for you taking submenu Extras gt Options limitations into account cf sec 4 9 3 9 Options event log page 135 All comments and messages which you have not filtered out are printed The selected function then prints the report entries as text on the connected standard printer and or creates a PDF file with the desired content After you select the respective PDF function a dialogue is opened in which you can indicate the PDF file name and path The storage path is the standard directory for report files The standard name is the addition Report followed by the name of the loaded report file e g Report file 20130401 REP PDF file Report 20130401 podf If the filtered report file is to be created as a PDF file filtered is added e g Report file 20130401 REP PDF file Report_20130401_filtered pdf 4 9 3 5 Export report There are two possible ways to export a report a report file All entries in the report file complete list This function exports the complete report file It contains all messages and comments The current list as displayed and filtered filtered list This function exports
49. rrornrnnnrennnnrr 31 Changing a Softkey rrrrnrrrnnrrernnnrn 30 Digital channels rrnrrnnrnnnrnnnrnnnnnnn 30 Disable control terminal 008 32 ET IS seiersen aaeain 33 Brei EE 23 Indicators onnonnnnannannnnannennnnannnnnnnnnne 30 Messages rrnnnrnnnnnnnnnnnnnnnnnnnnnnnnnnnnnne 29 Operational etatus 23 Mate 19 Program automatc 26 Goftkeys 30 Symbol and menu Dar 20 TEU CC 21 164 Trend oraph 27 Unit and error status 00nnaannannaan 23 Unit information cccccceeeeeeeeeeees 22 System requirementS anxennnnvnnnnuvnnnn 7 Table of ContentS ax rnnnnennnnernnnnennnnr 3 Temperature Shock Test Cabinets 143 O e e 148 Manual and program operation 148 Overview menu rrrnrennnrrnanennanenanennn 143 Hretermpertnmg 144 Program Stari sssrinin 146 Test program creation rnrnnnrnnnrnnn 147 Test cycle program editor BUTTONS JR 59 Call Subprogram rrrnnnnnnrnnnrnnnnnnnnre 75 HANGS ING iesccridectnendicsieacisndatanneverdoand 60 Changing a value me 66 Comment 87 Conditional wump 76 Convert program mee 80 Oo ll 61 Cursor NE ae 81 Ga EE 62 Delete lines rrrnrrnnnrnnrrnnnrnnnrnnnnnnnrn 61 Delete test program 70 Edit a block of lines rrrnrennrennnrnnrrn 72 EINES 60 Edit multiple lines ccsccseeeeeees 61 Expand all I00ps c seeeeeeeeeeeees 79 Generate a test cycle 60
50. sec 4 5 3 16 p 110 User Manual Section4 Program parts and functions 4 5 3 Graphical measurement data analysis functions 4 5 3 1 Open and load measurement This function opens a window with which any GI D PRO measurement can be loaded File load Unit No Measurement c ACID PRO 4 00 messung Filename C 70 350m01 Start Time from 05 09 2008 09 45 10 No of Channels End Time to 08 09 2008 11 35 33 nalogs 24 No of Lines fous Digitals Comment at 70 350m01 Active record In the central area are data describing in detail the measurement currently selected in the Filename field Start end time Number of analogue digital channels Number of lines i e measurement values Measurement data comments Unit No defined which unit measurements should be loaded All displayed data relate to this unit number If this is changed the files list in the Filename field switches to the selected unit no Filename lists all files that were recorded with the selected test unit here unit 1 files mO1 If the cursor keys up down AN WW are used to switch to another file the data in this measurement file appear immediately along with the associated comments If the menu is clicked a list of all the selected units measurements in the given path opens here C CID PRO 4 00 messung in which the desired file can be selected The current path from which the measurement files can be selected stand
51. the COM port number of your PC This means you can only connect one test unit to each of your PC s COM ports Interface cable Test Unit PC RX 2 2 RX 3h DE hb T GND 5 5 GND SUB D SUB D 9 pole Max length 15 m 9 pole plug jack 150 CiD Pro 4 02 User Manual Section 5 Networking 5 2 Serial interface RS 485 max 15m length max 500m length no cross wired no cross wired I UU ME ME ME H bb Test Units 1 n If you wish to operate several units in series to one serial COM port or have longer cable lengths you will require the RS485 interface To do this you will need the RS232 to RS485 interface converter Connect the user PC and the interface converter RS232 to RS485 with a serial RS232 interface cable SUB D adapter cable 9 pole 25 pole socket plug The cable must be a non crossover Then connect the interface converter RS232 to RS485 and the first unit using a RS485 interface cable The cable must be a non crossover You can now connect the first and the next unit using a second non crossover RS485 interface cable Now continue to connect all the units e Set the unit address if required in the unit configuration on the seven segment operating panel using the key sequence E P P or using the touch screen operating panel you can set the unit address and the parameters for the serial interface under Mainmenue 2 3 gt Settings gt Interfaces The important thing is that all unit addresses for e
52. the computer on which you want to install CID PRO 4 02 Log on as a user with administrative privileges It is recommended that you close all running windows programmes before starting the installation Place the CD into the drive of the computer If the CID PRO 4 02 installation file does not start automatically please open it directly from your CD e g dNCD Start exe Select your language In the following there are different CID PRO 4 02 software versions and a few tools available dk CTS Software Setup CID Pro 4 02 English CID Pro 4 02 CID Pro 4 02 CTS ASCII protocol Adobe Reader Back GUI MA TEMPERATUR SYSTEME CTS Software Setup Please select the application of the list that you would like to install CID Pro 4 02 version When the CID Pro software is installed the standard network version installed only allows Ethernet communication lf the test units are to be connected via the serial interface the full version has to be activated using the supplied dongle Besides this the driver for the hardware key Is also necessary and has to be installed GID Pro 4 02 When the GID PRoO software is installed the standard network version installed only allows Ethernet communication If the test units are to be connected via the serial interface the full version has to be activated using the supplied dongle Besides this the driver for the hardware key is also necessary and has to be i
53. wired cross owe i f ger sui e g IP Address 192 168 1 20 IP Address 192 168 2 90 Subnetmask 255 255 255 0 Subnetmask 255 255 255 0 Std Gateway 192 168 1 1 Std Gateway 192 168 1 1 CID PRO 4 02 software offers the possibility of networking over an integrated corporate network A LAN Local Area Network with a correctly installed TCP IP protocol is prerequisite GID PRO 4 02 software establishes communication with a fixed IP address This can lead to problems in networks with dynamic address assignment DHCP Dynamic Host Configuration Protocol User Manual for CID Pro 4 02 153 Section 5 Networking Connect the test unit to a free network outlet with an RJ45 patch cable Connect your PC to a free network outlet with an RJ45 patch cable Your network administrator must activate the network outlet and the cable must be a straight through patch cable e f required go to Mainmenue 2 3 gt Settings gt Network on the touch screen op erating panel in the units configuration to set the parameters for the Ethernet inter faces Units with 7 segment operating panels do not have an Ethernet interface These must conform with e You should set the same parameters for the Ethernet interface in the configuration of the CID PRO 4 02 software cf sec 4 2 2 Communication Ethernet interface page 37 You must request the required parameters IP address IP port subnet mask and default gateway from your network administrator I
54. you want to accept the values IS CID Pro Message Would you like to receive the bitmap information width 1115 px and height 681 px Wes e NO leaves all values unchanged e YES accepts the new values and changes the window s sizes Take note Width and height pixel values must be four place That means they must be padded with Os if necessary Dimension information must be completed in the format _wwww_hhhh The underscore signals the entry of dimensional information to the system Consequently no further underscores are permitted in the rest of the name Test Units 140 Here you can select your own unit image for each test unit Go to the desired test unit with the Unit No As orientation the section captions change when the unit designation is entered e g Climate Cabinet Test Unit 01 You can use the WW button to select a bitmap or JPG file which can be used as an im age for the selected test unit The successfully selected image is displayed as a path under the button The aspect ratio option is related to all the test units and enables you to show the image in the saved dimensions or not when loading the image If the option is set the aspect ratio between width and height remains the same if you change the size of the image there is no distortion If the option is not set you can change the size of the unit images as you wish gt the images will distort CID PRO 4 02 User Manual Section4 Program p
55. 09 10 13 09 10 13 09 10 13 09 10 13 09 10 13 09 10 13 09 10 13 09 10 13 09 10 13 09 10 13 09 10 13 09 10 13 09 10 13 09 10 13 09 10 13 09 10 13 09 10 13 09 10 13 09 10 13 09 10 13 05 10 13 09 10 14 59 22 14 59 25 14 59 25 15 11 23 15 11 54 15 11 55 15 11 55 15 12 00 15 12 00 15 13 05 15 13 14 15 13 14 15 13 14 15 13 21 15 13 24 15 13 24 15 13 44 15 15 25 15 15 25 15 16 09 15 16 17 15 16 36 15 16 57 15 16 57 15 16 58 15 16 58 15 16 58 15 17 05 15 17 07 15 17 08 15 17 13 15 17 32 Test unit stopped in manaual mode Program end Measure file c CID PRO 00 messung C_ 0_350 m01 closed after testcycle finished Cycle CL 70 350 201 transfered on Prg number 1 Program number 1 started STARTING TIME 15 11 00 13 09 2010 Digital channel Temper set to 1 Test unit started Program CNCID PRO 4 Nische 70 350 201 number 1 started Measure file c CID PRO 4 00 messung C_ 0_350 m01 with 60 sec interval started with testeycl Test unit started in manual mode Digital channel Dig outp 1 set to U Waming door is open 01 684 Program CNCID PRO Nische Schock ai number 99 started Test unit stopped in manaual mode Error Power switch feed 00 21 Program end Weaming install compressed air 10 663 Digital channel Temper set to T Eror Float switch waterbath 07 B80 Digital channel Temper set to 1 Temper setvalue changed from 30 0 C to 20 0 T CID Fro END 4 01 004 2 Full version CID
56. 2 37 Section4 Program parts and functions Client Server Setting 38 With client server communication you can query the unit s values from other PCs via the computer connected to the unit The PC that communicates with the test unit is set up as the server The other PCs which access its data are clients The servers IP address and a port number common to client and server recommended range is 2000 to 2050 must be set up on the clients It can be furthermore specified on the server whether the connected clients may change values in the unit Take note It makes sense to install the CID PRoO 4 02 network version otherwise a dongle will be needed Server setup example Type type determination server IP address PC address e g 192 168 1 100 Port common port number 2010 Allow client control DN Client setup example Type type determination client IP address server IP address 192 168 1 100 Port common port number 2010 A further path adaptation for storing individual files makes sense for optimal use of the networking It is recommended that directories be set up on a file server to which the participating PCs have access These directories can be designated in the following way Configuration files CID_Netz konfig Measurement files CID_Netz messung Test programs CID_Netz zyklus After the network administrator has set up these directories on the network directory paths must be changed i
57. 2010 08 26 14 30 00 m01 and re saved so that recording can be continued with the original measurement file Activate the second file format variant and define a text substring if you still want to append another text Example text substring A375 stored measurement file C CID PRO 4 00 messung Test SensorA m01 automatic file 1 C CID PRO 4 00 messung Test SensorA_A375_2010 08 26 14 30 00 m01 automatic file 2 C CID PRO 4 00 messung Test SensorA_A375_2010 08 26 15 30 00 m01 CID PRO 4 02 User Manual Section4 Program parts and functions The settings for the cyclic storage of the recording are accepted with Activate and discarded with Back A green LED in the manual measurement recording window indicates the activated cyclic storage after activating the recording 2 Recording of U01 Climate Cabinet Start options Record options oO Start now Recording all seconds 460 0 Date activate activate The activated cyclic storage is also displayed in the status overview s top bar again identified by a green LED Next to it the days hours minutes and seconds remaining before the next storage are shown o To the next storage are exactly O days 0 hours 36 minutes and 52 seconds User Manual for CID PRO 4 02 121 Section4 Program parts and functions The recording starts if these settings are accepted with OK Such a manual recording changes the selected test unit s background in the uni
58. 9 Index 166 CiD Pro 4 02 User Manual Section 10 Technical support 10 Technical support Please visit our website at www cts umweltsimulation de for more information about CTS GmbH and GID PRO 4 02 software It delivers the latest information on the continuing development of the company and of CID PRO 4 02 software Our distribution partners in over thirty countries stand ready in word and deed to answer licensing and acquisition questions concerning our software You can find our partner names and addresses in website s contact area We are glad to refer you to a partner in your area CTS GmbH Lotzenacker 21 72379 Hechingen Germany Tel 49 0 7471 98500 Fax 49 0 74 71 98 50 23 E mail info cts umweltsimulation de Web www cts umweltsimulation de User Manual for CID Pro 4 02 167
59. Activate password security E A simple password should be used when a complete GID PRO 4 02 software lockdown is desired The entire interface can be locked this way by entering a password All areas can be opened and displayed in this mode Changes however are ignored with the message Change password Password security is active settings Function is not available You protect CID PRO 4 02 from unauthorized access with Activate password security Activate password security Therefore the password query opens The password on initial program start is cid pro Take note Please pay attention to case upper lower case 46 CID PRO 4 02 User Manual Section4 Program parts and functions If the password is correct CID PRO 4 02 prevents all write accesses by the user to the test unit or files The following actions are no longer possible e Setting set analogue channel values Changing digital channels Accessing the automatic display Accessing the recording display Recording termination Storing generated cycles in the editor Changing comments while measuring Configuring the test units Exiting CGID PrRo 4 02 You can change the default password to your own password with the change password button J Change password IS Change password Actual password tii new password Repeat new password ieii new password f CID Pro Message New password accepted
60. DS 2008 112523 k VE 1 I d V No of ner 7807 Fi 7 DS d V f E d 030 l LAL Sn b DW d f 5 i LI fi NI UE pan tn 17 31 10 gn 21 15 10 16 57 10 AR 10 DEA 18 21 05 BGA 10 07 57 10 re mies 00 04 D DE 08 D Bod efe DA apin 20 070305 Car ind DE AIS GI Temper Fedde lau 2 T Tap FC j gt 1000 we 2 Sei emm mm 9 ce pop or 323 ioe 15 1 31 1 54 Take note At the first start of the graphical measurement data analysis default settings are defined Failing to see a graph after loading a measurement may be caused by the following The selected file is empty or new contains no data yet No legend is shown so most probably no channels were selected in the measurement data record configuration or the settings were not saved as default so that they were lost when the measurement file was requested Sec 4 5 3 9 Options Graphical measurement data analysis page 100 describes the exact approach to channel selection in more detail User Manual for CID Pro 4 02 91 Section4 Program parts and functions 4 5 2 Buttons Menus File Zoom View Extra Settings Help Comment 92 Symbol BOXU POF Gg Re CE 1 48000000000 Submenus Open Delete Print Print as PDE Files last opened Exit Complete Frame Restore Zoom Out Zoom Zoom to cursor positions Display Analysis Option
61. E E E E Driver for the hardware key dongle cccscccseecceeeeeeeeeeeeeeeeeceeeeeeeseeeseees ASCII protocol test Progra ape a i ASCII protocol for the serial mtertace ASCII protocol for the Ethernet interface rrrnnnnnnnnnnnnnrnrnnnrnnnnrnrannnvanennnn Manuals and Adobe Acrobat Header 2 5 VUNNET gt Program Star Up EEE EE EE 3 1 ME 3 2 rm 4 Program parts and functions 4 4 1 SAUS EE 4 1 1 4 1 2 4 1 3 4 1 4 4 1 5 4 1 6 4 1 7 4 1 8 4 1 9 4 1 10 4 1 11 4 1 12 SE EE EEE ET E A NE EE STN re EEN Unit information EEE EE Unit and error etaiusg cece cece eee eeeeeeeeeeeceeeeeeeesecaeeseeeseeeseeeseeeseeeseeeseeesaees FP FOO 12 1 0 re 0 1061 0 EE EE E PICHON AD EEE Messages change warning and error MESSAGES cccceeeceeceeeeeeeeeeeeaees DIG Ie ga EE EN Analogues channels A Disable COMMON ET Aden ETT 4 2 Configuration CID Pro 4 02 Settings rrrrnarrrnanrnrannrnranrnnnnnrnnnnrnvanrnvannnnnnnen 4 2 1 4 2 2 4 2 2 1 4 2 3 4 2 4 4 2 5 4 2 6 4 2 6 1 4 2 6 2 4 2 6 3 4 2 Le EE EEE A E E COMUNICATO EEE EEE Help for adding Test Units into software Program mode temporary transient display n0nnn0nnannnenneneennnennnnnnnnnennnne ES de 109 protection RE EEE EEE EEE EE EEE KOMM Simple D ssword Access Configuration Gettmge Access Configuration In runtime operation rrrrnrrvrnnrrrrnrrevnrrnrnnrennnrrennn FF NN 4 3 OVErEN of all EST
62. Insert line change gorapb 64 Insert Hrogram 17 Insert value me 60 64 Loop loop beginning and end 74 New test program 69 Open test program rrrnnrnrnnnnvnnnennnre 69 ODUN S esne E E 79 Past copied Ines 62 ere I FE FOR E 72 Print both graph and list 72 Print graph 71 Klek gt E 72 Belger 72 Printer page sein 71 Printer page setup and print 71 Programs IN unt 81 Read proglist of contr rrrnnennnennnr 81 Retroactively insert a values line 67 68 Save as test program 70 Save file as library rrrrrrnnrerrnnrrnnnre 86 Gaveilemdaiapoool 86 CONIC EE 80 Set Gradient nannnannnennnannnennnennn 82 Software Im 63 Templates A 78 CID PRO 4 02 User Manual Time Avis 80 Zoom functions rrrnnrnnnrnnnrnnnrnnnrnnnn 88 VANNS UU 15 Visualization Aspect TAO Linden ker 140 Background Image 139 Ettel EE 137 Configure Setting 139 Display Test Ulnte 142 Display the vsualtzaton 138 Load SCUING Lassen 142 Moving the Mouse s onnannnnnnnnnnnnnnnn 138 User Manual for CID Pro 4 02 Section9 Index Se 137 Reset setting rrrnnrrnnrrnnrnnnrnnnrnnnrr 142 Save Setting 141 Test Bn CC 140 Visualization functions 0 aaaanaanan 139 Window Size width x height 139 Wait function aranannnnnnnnnnnnnnnnnnnnnnnnnnnn 62 Zoom Full ecreen 90 98 ZOOM 90 98 ZOOM OU ae 90 98 165 Section
63. Installation and system requirements 2 43 2 ASCII protocol for the Ethernet interface This test program offers you the option of checking the Ethernet interface communication with the test unit using a couple of mouse clicks IP address Must agree with the IP address set at the test unit TCP Communication red no communication green communication OK left area Status selection sent and received character Possible commands Selection of all commands which can be sent to the equipment Display mode Display of characters in plain text See figure or in actual transmitted bytes Display mode TCP Communication _ all transfered bytes J encoded Gei Receive bytes 14 IP address received characters ChanelNo 0 actvalue 106 4 setvalue 100 0 ChanelNo 0 actvalue 106 4 setvalue 100 0 ChanelNo 0 actvalue 106 4 setvalue 100 0 ChanelNo 1 actvalue 079 3 setvalue 000 0 ChanelNo 1 actvalue 079 3 setvalue 000 0 Please note Please adjust the IP port 1080 to the test unit 2 4 4 Manuals and Adobe Acrobat Reader The software s PDF manuals are displayed if you have access to Adobe Acrobat Reader Click the reader s desired language and follow the installation instructions if you have not yet installed the reader 14 CID PRO 4 02 User Manual Section 2 Installation and system requirements 2 5 Uninstall To remove GID PRoO 4 02 from your system open Control Panel from the start menu s Settings a
64. OSE OZ D SMPAZO0 OO ON AP ER LO Oct 80 010 8090 AER JOU SJUNGIJDE sasn 1 Z 80 01028090 E Jun 159 0 UOD UUOD ON i a i 089 0 EAM YDPMS OU 018 Jou D OL Xapu UO uu H1 Ut pm 3 ut duet DER DOS osc 0007 Dt DOS osce 000 osz oosz OSET 000 OS I oos Ose 1 0001 CG EL oL S D JG sms Or ul JUEUSIEM D ee SE sjeuueyo Fi EN sonboyeuy H Ul NPWUnH Bee DIr ae Bar 2 ul sodway Py Jee sjauueyy bojeuy weibeip weibouid 10 udeib puaup Lt sjauueyd jeu big e n gt dmaq ueg 1S 10114 GL Lt GLP aa Zdino Big P Dpum 1 L D Con JE Dassaudwos jesu Co e Gu nese e gions 210 E SJOJEDIPUI s awyos See SNE sj uuey9 ENDIG SLI Piret en HUN 353 1 uIge gt 353 A2045 354 10113 o1y denon Preface me 005 og oIyderpual dn HOO Dpurm 3 YSZ Jadwaj san ea as sj auueyp Sane sdooj ou onewone beem 6Z 80 10 eau L ON weibold SEN a a cn otCerg pose H LP ss wuruu E 1Z 00 au pesdeg LOZ OSE OZ D L weud amp oHewo Ny x EE D AEN OCH snes EJL KOLL A ay doe 10449 K VEIS pue yun sss Sv pun 159 pauuejd x z uge andwa uge sel gt 04s yeuige aneJedwe youlgey seu PS spun 159 sun egal Eby UONEUILIOJUI Hun VLD os 0 D OSCH 3 LON 1eu rqeg Jew SZ 9mMOrl k du suoouny jg UOISIBA Up TO p Od AD Al
65. P address information is unique within the network meaning that it may only be assigned once 5 4 Network Version Remote PC A second PC can be connected using the company integrated LAN network Local Area Network Here the GID PRO 4 02 network version which can be used to observe current conditions of all the units connected is running This takes place using the standard CID PRO 4 02 software interface Please cf sec 4 2 2 Communication Client Server Setting page 37 for setting this type of operation in accordance with client server model 5 5 External devices It is possible to integrate external devices with CID PRO 4 02 software These external devices from other manufacturers are addressed by means of a protocol converter a so called gateway hardware Gateways convert different units interfaces in a way so that the devices appear to be CTS devices Beyond this there is a special version of CID PRO 4 02 software that can integrate the external devices using software You can determine which solution hard or software is right for you directly from CTS GmbH s technical department 154 CID PRO 4 02 User Manual Section 6 Buttons of the CID Pro 4 02 software 6 Buttons of the CID Pro 4 02 software 6 1 Status overview Symbol A A ON i i D PP a X i Z User Manual Description Link Exit Visualization section 4 10 page 137 Display your test units in a self
66. There are two options for entering a set value In one the set value can be changed by sliding the arrow symbol located directly under the set and actual values To do this left click on the arrow symbol and keep the mouse button depressed Now you can move the mouse to change the value The second option is to click on the set value in the display field thereby activating it numerical colour changes Now you can enter the value through the keyboard Note that a point must be used as the decimal delimiter The entry is confirmed with the enter key If you released the mouse button in the first option or confirmed with the enter key in the second option the test unit receives this new set value If your test unit configuration contains more than three analogue channels the analogue channels screen adds two paging symbols and which enable back and forth paging of the analogue channels gt User Manual for CID Pro 4 02 31 Section4 Program parts and functions 4 1 11 Disable control terminal Clicking the key icon ka opens a window showing whether the active test units control terminal is enabled or disabled SE Control Panel state control panel unblocked Back You can change the state with a mouse click on the desired switch position The new setting is transmitted to the unit with the OK button All key presses at this unit s control terminal are ignored if the keyboard is disabled Take note The key
67. UNS saa Ee 4 4 Test cycle program editor rrrrrnnnrrranernnnrnnnennnrnnnnennnnnnnnennnnrnnnennsnnnanennnsnnnsennnnennee 4 4 1 4 4 2 2 1 ee Pils User Manual for CID PRO 4 02 Section I Table of Contents 4 4 3 Generate a test cycle 60 4 4 3 1 Edit lines insert change delete cut and copy with keyboard menu later 6 EE EEE 60 4 4 3 2 Insert line and change graph with emouse 64 4 4 4 FN oreina E E E S E A 69 AAA ET gue e e ET 69 4 4 4 2 Open test program rrnnnrnnnrvnanrvranrrvnnnrrranrnrnnrnrnnrrnnnnrnnanennnnnennanennusennnssnnnnee 69 4 4 4 3 Save as test program 70 4 4 4 4 Delete test program 70 4 4 4 5 Printer page setup and print n nnannnenneneennnennnnrsnrnenrnrrnnnrerrenrrerrsrrreresnene 71 AAA PUNAS DEE EE 72 4 4 4 7 Copy insert a block of lines delete a block of mes 72 4 4 4 8 Loop loop beginning and end 74 4 4 4 9 Call Subprogram rrrrnnrnrnnnnnanerrnnrevnnnenranrnnnnnennnnennnnennnnennnnnennnsennnnsennesennnee 75 44410 Condional Un le E 76 4 4 4 11 Insert FOR rek kes gler TT 212 Tage 78 44413 ET Eee ed 79 AAG NG Se le ene 82 4 4 4 15 Save file in data pool rrrarrrnnnrrnnnnrrnanrrrnnnrnnnnrnranenrannnnnnnrnnanennnnnennnsennnnennnn 86 4 4 4 16 Save file as library rrrnnrrrnnnrrrnnnvrnnnrrnanrvvnnrnvnnnnnnnnrrnanrnnnnnnnnansnnnnnnnanennnnne 86 AA AAT Editor een 87 2215 Editor ZONE 88 4 5 Graphical measurement data analysis rarernnrrrnnernn
68. User Manual Computer Integrated Documentation PRO 4 02 User Manual CTS GmbH Lotzenacker 21 72379 Hechingen CTS GmbH CID PRO 4 02 User Manual Rev 2013 04 15 1997 2013 CTS GmbH Lotzen cker 21 72379 Hechingen Germany http www cts umweltsimulation de Text figures and examples were created with the greatest care The issuer assumes neither legal nor any other liability for erroneous information and its consequences This document is copyright protected All rights reserved No part of this documentation may be reproduced in any form by photocopy microfilm or other processes or translated into a language usable by machines particularly data processing equipment without the issuer s written consent The rights to reproduce via lecture radio and television are also reserved Microsoft Windows and Windows NI Windows 2000 Windows XP Windows 2003 Windows Vista Windows 7 and Windows 8 are registered trademarks of the Microsoft Corp Redmond USA CTS and the CTS logo are registered trademarks of the CTS GmbH Hechingen Germany 2 CID PRO 4 02 User Manual Section I Table of Contents 1 Table of Contents 1 Table OTC ONIENIS 2 EE 2 Installation and system requirement S x ranrranvnnnvnnnunnnvnnunnnnnnnnnnnnnnnnennvennnnnnvnnnvnnnunnne 2 1 LICENSING ue SEE cane tansenaecuncsianalyens 2 2 SEELEN 2 3 EIERE 2 4 TAES EL Es OUR EEE EEE ER 2 4 1 2 4 2 2 4 3 2 4 3 1 2 4 3 2 2 4 4 ADP A O e a
69. Yes Light red Channel 1 Right scale O No temperature Y max 200 Y min 100 Set value M Yes Dark blue Actual value M Yes Light blue Channel 2 Right scale O No humidity Y max 100 Y min 0 Set value M Yes Dark green Actual value M Yes Light green Channel 3 Right scale ONo Y max 0 Y min 0 Set value M Yes Black Actual value M Yes Dark grey Channel 4 Right scale O No Y max 0 Y min 0 User Manual for CID PRO 4 02 101 Section4 Program parts and functions Display You have additional options in the display to adjust the graph to your Generally Mener Show Cursor IM High detail You can make the cursor visible Wl Show Small Display W Min Max Resolution here this is recommended when E Show Evaluation 0 500 printing several curves You can show the Small Display Real Time and the Min Max values cf sec Wl Show Real Time 4 5 3 7 Display page 99 and EM gt I 4660 00 show the evaluation analysis E cf sec 4 5 3 8 Analysis page Hon 5 99 OH D You can present the entire ie ee measurement value display in more detail if you check the High detail Time 09 45 10 Time 15 45 10 option The measu rement value are 050A 05 45 10 TETAI 11 35 33 presented in detail to a resolution of Save Seve 0 1 units reduces operation speed Format Display AM PM hh mm 24h hh mm ss If you want to permanently define the time scale deactivate the Show Real Time display fiel
70. a You can repeat this procedure up to 19 times In other words you can zoom 20 times Proceed as follows to enlarge the desired area 1 Right click the desired area s upper left corner and hold the mouse button down 2 Now drag the mouse with the depressed right button to the desired area s lower right corner 3 The zoom function is applied after releasing the right mouse button and the selected area is enlarged Lu RM ZE times E w aea Lt AUTI User Manual for CID Pro 4 02 97 Section4 Program parts and functions Take note The point connectors visible gradients can be displayed differently after zooming if the relation of the x to the y axis no longer agrees Checking the gradients by calculating the y segment length over x segment length shows that the gradient is in fact unchanged You can repeat this zoom process up to 19 times cf sec 4 4 4 18 Editor zoom functions page 88 for a more detailed demonstration Fullscreen AY Return from any arbitrary zoom level to the overall view full screen Zoom out X Zoom out a level shrink Zoom Kei Zoom in a level enlarge assuming youve already defined this level If not then the function or button is greyed out That way you can always identify how far you have already zoomed Zoom to JD cursor positions Place the cursor on the desired area and zoom exactly into it Take note You can only zoom with precision on one
71. a S Ca 0 60 0 so ai 00 O 40 0 00 og 200 00 eof 200 00 In the process the lines to be deleted from yellow through pink are colour coded The list is adjusted and updated if information is changed lt 10 always lt as ts User Manual for CID PRO 4 02 og au og al ad rg o 400 60 400 o 600 HU SI TI sl GE allalla 73 d Section4 Program parts and functions 4 4 4 8 Loop loop beginning and end You can repeat certain cyclic processes with a loop A loop beginning and an end are needed for this Moreover the number of repetitions must be defined at the beginning of the loop Loop beginning To program a loop activate it with a left mouse click on the line after which the loop is to begin Finally press the loop beginning function in the tool bar or the F2 key The display in the table is as follows The 1x in the time column indicates that at the moment the loop will iterate once You see a vertical pink line on the graph as a check indicating the beginning of the loop Double clicking on the loop beginning line opens the adjacent window for entry of the loop number This is accepted with OK Loop end Activate the line after which the loop should end with a left mouse click Finally press the loop end function in the tool bar or the F3 key The display in the table is as follows You see a vertical purple line on the graph as a check indi
72. accepted with OK only when both entries are identical 3 J Change password Usemame Old password New password New password check Cancel Take note Acceptance of changes in access configuration occurs globally requiring no additional storage as long as you possess change privileges To accept mode change from simple password to access configuration and visa versa the setting must be stored with the save settings button and CID PRO 4 02 software must be restarted 52 CID PRO 4 02 User Manual Section4 Program parts and functions 4 2 6 3 Access Configuration In runtime operation The status of logged on users is displayed in the status overview if you have activated access configuration Administrator logged on The meaning of the key symbol and user text is as follows Access Configuration Inactive active open locked REES logged on not logged on AN AN Symbol E E User User User ER Administrator cts No user enua logged on logged on logged on No entry The user is logged In this mode the user In this mode no user is Explanation present on as administrator has logged on as cts logged on That means in this mode and and has the privileges you have no privileges to consequently has full that were defined for user execute the defined access to all of the administration functions to service the software s functions software d M ro User logon E gt E
73. ach unit are different The settings must conform with e You should set the same parameters for the serial interface for all connected units in the configuration of the CID PRO 4 02 software cf sec 4 2 2 Communication Serial interface page 37 In all connected units the COM port in the configuration is the same The units are differentiated only of the unit address In addition to this note the COM port number of your PC User Manual for CID Pro 4 02 151 Section 5 Networking Interface cable Connecting cables are to be built as shielded 4 conductor cables like LIYCY 4x0 25 mm Connecting cable Test Unit PC RS485 RS232 converter 1 Phoenix PSM V24 V11 Test Unit PC Converter p Max length 500m from the 7 pike p PC to the last device p plug plug 2 W amp T Nr 86000 Test Unit PC Converter bae Max length 500m from the De p PC to the last device P plug jack Connecting cable Test Unit Test Unit Test Unit Test Unit ge Sea Max length 500m from the e See p PC to the last device A plug plug 152 CID PRO 4 02 User Manual Section 5 Networking 5 3 Network TCP IP e Either 1 1 cross over e g 192 168 1 90 e Or Standard Gateway m n connection IP 192 168 1 1 Im n Test Units with one PC and m 1 from m PCs access to one Test Unit Address area 192 168 1 xxx Address area 192 168 2 xxx Subnetmask 255 255 255 0 Subnetmask 255 255 255 0 L AD NM cross
74. allation you can select the destination directory into which GID PRoO 4 02 software should be installed The default is C CID PRO 4 00 You can change this directory It is recommended that you install the software on the local hard drive of the computer 10 W CID Pro 4 02 Destination Directory Select the primary installation directory All software will be installed in the following locations To install software into different locations click the Browse button and select another directory Target directory for application Target directory for National Instruments software C Program Files 66 National Instruments CID PRO 4 02 User Manual Section 2 Installation and system requirements After successful installation the following message appears LY CID Pro 4 02 Installation Complete The installer has finished updating your system You can now close the start up window and use the software Take note User Manual First install CID PRO 4 02 software if you want to use the full version Finally start the Sentinel hardware key s dongle installation Only insert the provided dongle after installing the driver on the PC You may be asked to connect the dongle with the PC during driver installation In that case follow the directions in the menu Check whether the USB dongle is in a USB port and the Sentinel driver is installed Otherwise the software is started as a networ
75. ally adjusted and updated 68 CID PRO 4 02 User Manual Section4 Program parts and functions 4 4 4 Functions 4 4 4 1 New test program You can create a new test cycle program with this function First a selection of which test unit you want to create a new test cycle for appears Sak Test Unit Selection Sak Test Unit Selection For which of the test units do For which of the test units do you want to create a new you want to create a new Test Unit 01 C 70 350 Test Unit 01 C 70 350 v Test Unit 01 C 70 350 Test Unit 03 T55 70 130 Test Unit 04 T 40 600 Test Unit 05 After selecting a unit from the list and confirming with OK the editor is re built using the selected unit s configuration digital and analogue channels and their assignments A confirmation prompt appears if the previous entry was not yet stored 4 4 4 2 Open test program You can open previously created test cycle programs and load them into the editor To do this select the desired file from the list and click on load S Cycle select Directory C CID PRO 4 00 zyklus History Look in Ji zyklus sl amp E Br Name che PA e A sample Recent Places e A tss_cycl WE J 70 350 201 Desktop Libraries A Computer Network mW p File name C_70_350 v Files of type 201 e Cancel To open a file with another unit s configuration change the file type and file name for example from Z01 to Z02 gt Z01
76. alues appear and are greyed out in the width and height 500 x 375 fields 600 AED Full screen maximizes the window and also sets and greys out 200x 400 the values in the width and height fields The user defined function clears the width and height fields into which you can enter the desired values fullscreen vw user defined Take note Changes are accepted immediately Background Image You can select the background image as a bitmap or jpg file with the W button The successfully selected image is shown as a path name below the button You can use your work place s laboratory s or production hall s layout chart as the background as well as bitmap or jpg files you design and construct yourself Since the properties of the image in this file rarely agree with those of the screen it makes sense to adjust the background image s window sizes width x height User Manual for CID PRO 4 02 139 Section4 Program parts and functions Either you enter the dimensions yourself in to the width and height fields or you give your image file the dimension information via a name change This change works as follows e Create your image file in bitmap or jpg format e g FairplanElectronica jpg e This file is 1115 pixels wide and 681 pixels high e Name the file in the way to Name www hhhnh jpg e g FairplanElectronica 1115 0681 jpg e If you now load this file this width and height information is processed and you will be asked whether
77. an error and lad shuts down if the channel s C 70 350 actual value undershoots the minimum value or overshoots the maximum value E L Configuration i l actual values for manual mode Manual operation values can be 130 0 130 0 Max changed These values are Tempinlet then transmitted to the unit and knee 200 80 0 Min apply when the unit is running and was Started in fixed value operation The current limits return which limits is currently stored in the unit Manual operation and current values can differ as long as an automatic program is running in the unit If you change the manual operation values during this interval they will only become valid after program completion Values valid during automatic operation are defined in the editor for the program in question User Manual for CID PRO 4 02 43 Section4 Program parts and functions 4 2 5 Generally Global settings default JE pr directories and general options can be adjusted for GID Settings Communication Pro 4 02 software in this Test specimen protection ENG Default Directories Measure Files Default Directories CACID PRO 4 00 messung m The default directories are the Repor Files paths for the measurement and CACID PRO 4 00report report files test and sample Testcycles programs as well as C XCID PRO 4 00 zyklus m configuration and visualization Samplecycles files C XCID PRO A DD zytdusisample el Contig Files The configura
78. and maximum limits of 0 0 are entered respectively if you have already worked with earlier GID PRO program versions In this case channel limitation occurs in accord with its input limits Take note For Points 5 7 copy cut paste lines there is a cross program line resp block storage Copy a line block in the first program and insert this copy into the new or second program User Manual for CID Pro 4 02 63 Section4 Program parts and functions 4 4 3 2 Insert line and change graph with the mouse 1 64 Insert value line For an empty program you have the option to set a point by clicking the left mouse button The first click in the graph plots a point at time O and the value at where the mouse points initialization point All other points are plotted as follows Time axis x coordinate coordinate is snapped to the nearest forward or backward full second minute or hour Values axis y coordinate coordinate is plotted on the exact value at which the mouse is pointing The point plotted with the channel s colour temperature gt red The information on the upper right edge facilitates exact point plotting since it shows the mouse coordinates relative to the graph So in this example 902 min and 63 C Information depends on displayed scale Cursor tmin 833 64 00 GE Hstd 14 55 1 67 min Time Temper Humidity deepdeh Dig outp 7 t in C in rH 1 D2 When clicking on the
79. approach also applies to the retrospective editing of the test pro gram In other words you have defined two points e g temperature value and time which you now wish to adapt If you select the last line as the start line you will also require additional information about how long the ramp should last The time field takes the temporal Temper Gradient with distance over into the calculation Rise of line EE The Y coordinate e g temperature is calculated with the help of the gradient and the temporal distance and this point is then created in the editor Gradient alle 1 0 K min for CID PRO 4 02 83 Section4 Program parts and functions 2 to time calculation IS Temper Gradient to You use time calculation to determine the x coordinate Face of line P of the next point temporal duration with specified y coordinate of the next point e g temperature value and the desired gradient A You mark the line in the value list that you want to serve Gradient w 2 5 K min as the starting point for the defined gradient Then you activate the Gradient to function in the Extra menu or the F9 key You can enter the settings for the defined gradient in the Hasla following window m Rise of line Gradient starting point Gradient Gradient in K min Heating or cooling is provided by entering the y coordinate e g temperature y Temperature General calculation Gradient
80. are not of importance Note The open measurement file is not changed by this display 4 5 3 12 Copy to clipboard To be able to insert the current graphical measurement data analysis view into Microsoft Word the view must be copied to the clipboard This function saves the screen to the clipboard as a picture You can ultimately insert the view into all programs having access to the clipboard and consequently the ability to insert images Microsoft Word Microsoft Paint Microsoft Photo Editor or even Corel Photo Paint for example insert it as a new image The view described here describes the graphical measurement data analysis screen without symbol or command bar as saved to the clipboard View analysis arrangement whether and where the dialogs are located zoom factor is a section displayed enlarged options setup which channels are presented and the program size itself can be determined and are taken into consideration when copying to the clipboard A comment will be displayed at the top of the copy stating the software version copy date and time and file name and path CID Pro 4 01 full version 06 09 2010 15 41 10 CACID PRO 4 O0Vmessung WC 70 350 m01 106 CiD Pro 4 02 User Manual Section4 Program parts and functions 4 5 3 13 Merge measurement files This function gives you the opportunity to merge measurement files You have for example split measurement files or you only want to merge part of a measurement
81. arts and functions The option can also be set afterwards The properties are corrected in this case only during the next image change If you change an image the smallest page is set the largest page recalculated when the option is selected Original image Change Option Result U01 Climate Cabine U01 Climate Cabine UOL Climate Cabine 4 10 4 2 Save setting For different presentations you have the option to store the adjusted configuration s setting Go to the Extra gt Save Settings menu option and enter a characteristic name for the file name The file extension is vcg visual configuration xtra Configuration Ctrl C Load Settings Ctrl L Save Settings Ctrl 5 ELE Reset Settings Ctrl R User Manual for CID PRO 4 02 141 Section4 Program parts and functions 4 10 4 3 Load setting You can reload the various saved configurations at any arbitrary time Go to the Extra gt Load Settings menu option and select the vcg file that you want to load The setting is accepted after confirmation and the visualization is completely reconstructed 4 10 4 4 Reset setting If you want to begin a configuration again from scratch choose the Extra gt Reset Settings menu option The saved settings are reset Le all image paths dimensions and positions are set back to the default values 4 10 4 5 Display Test Units The displayed test units from the program configuration cf sec 4 2 1 Configuratio
82. be set here All screens are laid out in the default 1280 x 1024 pixel size Several windows dimensions can be changed however Enlarging the window does not just create a zoom effect but also a partial rearrangement of the window s content so that the information can be presented as clearly as possible The setting can be selected by positioning the red marking arrow The setting then applies to al CID PRO 4 02 software and is retained even after restart Use last size The sizes of the Status overview Test cycle program editor and Graphical measurement data analysis windows can be changed The most recently set dimensions are used the next time the window is opened Fullscreen window The sizes of the Status overview Test cycle program editor and Graphical measurement data analysis windows are expanded maximized on opening to exploit the entire display Take note smallest size 1000 x 700 All changes are only accepted with the save settings function and are completely effective after a restart These settings are program global and apply to all test units User Manual for CID PRO 4 02 45 Section4 Program parts and functions 4 2 6 Login Option CID PRO 4 02 is JE Configuration provided with two access authorization versions the menu changes depending on the selected authorization simple password e simple password 4 2 6 1 Simple CID Password Protection Access Configuration password
83. cating the end of the loop Take note Please observe that for each loop beginning a loop end must be programmed GID PRO 4 02 checks the number of loop beginnings and endings when you want to save the program An error message appears if this check should turn up different numbers The loops can also nested HS S2 a S1 Maximum number of different loops 20 Maximum number of the same loop 9999 74 CID PRO 4 02 User Manual 4 4 4 9 Call Subprogram If subprograms are to be used the subprogram must always be compiled first and then the main program Using the left mouse button activate the line after which the call is to be inserted to insert a Subprogram call Finally press the Subprogram function in the tool bar or the F4 key A window appears for the subprogram call You can select the subprogram s filename in this menu Moreover you assign the subprogram a location in the controller with the program number choice The subprogram is transferred to this program location when the program is sent The main program and every subprogram called must receive its own program number A main program can run only one subprogram at a time If a new subprogram needs to be started while the old one is still running the old subprogram is terminated Likewise all subprograms are terminated when the main program terminates The status display in automatic mode always relates to the main program That means the test un
84. ces Desine sw Joos Computer feet ork Remove A Confirm your selection with Remove All You ultimately delete all the files you selected after clicking OK in the confirmation prompt Take note You can choose the measurements data type from the connected configured unit or from among all files Handle deletion with care Deleted files and data are irrevocably lost User Manual for CID Pro 4 02 95 Section4 Program parts and functions 4 5 3 4 Print measurement The printer function prints out currently displayed and loaded measurement Print out options can still be changed before spooling the measurement to the printer s Print Printer Info Name SHARP MX 2300N PS Properties Status Idle Type SHARP MX 2300N PS Where d Eject page after printing Comment Print to file Graphics Options I Force black amp white Width Entire paper v 1 Height Entire paper y A Scale to screen Horizontal offset Centered v Bo 7 Visible area only Vertical offset Centered v i Use Bitmap Printing Ge The printer can be selected in the upper area from among all installed windows printers Printer specific settings like colour or grey scale printing portrait or landscape or intake and exit paper tray can be made for the selected printer in the Properties field Additional properties for the displayed measurement can be set in the lower part of the window Width and Height Hardcopy width an
85. cknowledged but only provide an overview of the current errors warnings User Manual for CID Pro 4 02 33 Section4 Program parts and functions 34 CID PRO 4 02 User Manual Section4 Program parts and functions 42 Configuration CID Pro 4 02 Settings Basic CID PRO 4 02 settings can be selected in the configuration menu 4 2 1 Settings With the Number of test units you set how many test units you have connected and CID PRO 4 02 should administer This number is the maximum number of units that you can deal with in the communications settings IS Configuration Number of test units 5 The Language sets all CID PROD 4 02 texts and messages to the selected language at run time Language English User Manual for CID PRO 4 02 35 Section4 Program parts and functions 4 22 Communication In the Test Unit Specific Setting you first select the Unit No that you would like to edit In this connection only unit numbers from 1 to the SE Configuration number chosen in the settings Test Unit specific Setup cf sec 4 2 1 Configuration Unit No Settings page 35 can be Unit Designation Temperdise Cali 1 selected Scanning rate sech 10 0 communications parameters always apply only for this Serial Por selected unit ICT Unit communication via serial port The following parameters can be set for the selected unit Ethemet Unit designation Unit communication via
86. cle You open templates via the menu and save them possibly with small adaptations and under a different name This way you can separately save call and adapt ever recurring procedures These templates are comparable to Microsoft Word document templates dot which establish a document s basic structure 1 78 Ve ieee Create a EE EE LE test cycle program HH 7 E i gw ga wg ge ve de wn wo se er gw we ge Save it in the CID installation pathizyklusisample directory e g C CID PRO 4 00 zyklus sample lIEC 68 2 30 201 You can change or adjust this path in the configuration general paths register The next time the editor is opened thereby creating a new program this program s file name appears as an entry in the Templates menu SJ Test Unit 1 NewProgram Z01 File Edit Templates Extra Help Comment e 1 IEC 68 2 30 701 A test program opens in the editor when you click on this template Confirmation prompts concerning changes to an already edited new program are displayed first Modify this open program to meet your current requirements Save the modified templates in the CID installation pathizyklus directory with Save as under a new name characteristic of this application or test The Save as dialog shows the Zyklus directory as the default path e g C CID PRO 4 00 zyklus TestSensorAZ01 Take note The Save function without a path request so saving into the a
87. d Now set your desired X Max and X Min values Due to automatic division it is not always possible to maintain the permanently set time axis Small differences can arise If the graph should always adjust automatically make sure when you exit Options with OK or Default that identical values or Os appear in both fields a If you activate Show Real Time the time axis will be shown with exact time E information F 09 45 10 17 33 10 01 21 10 09 09 10 16 57 10 00 45 10 08 33 10 16 21 10 00 09 10 07 57 10 15 45 10 T 05 09 08 05 09 08 06 09 08 06 09 08 06 09 08 07 09 08 07 09 08 07 09 08 08 09 08 08 09 08 08 09 08 od Temner ee m You can define the appearance of the time axis yourself To do this enter the desired interval in the Start date time and Stop date time fields Conform to the existing input format or your entry will be ignored The actual start stop date is displayed in the field below which is entered in the date time field with Save The Time format can be varied using the Format and Display switches If you change the settings you can determine the changes directly from the screen and define them as defaults to best suit yourself Evaluation Hide Humidity actvalue if Humidity is OFF is a function controlling the 2 channel s actual D I hide Humidity actvalue if Humidity is OFF humidity value 102 CID PRO 4 02 User Manual Section4 Program parts and functions 4 5 3 10 Excel conversion program Measure
88. d height the default value Entire paper expands the plot to use the entire width and height of the sheet The printout s width and height can be alternatively given in 10 s of a millimeter Horizontal and Vertical offset The plot is centered on the page by default A value in 10 s of a mm can also be given however to adjust for the binding margin for example Force black amp white Useful setting when sending a fax because shades of grey are very badly transmitted via fax Bitmap printing A finer more optically appealing print image results without this selection But bitmap printout can make sense on ground of compatibility Perhaps this selection must be made when the printout doesn t work right Without bitmap printout problems can show up in connection with some printer drivers especially when the PC has little memory 4 5 3 5 Print measurement as PDF The function Print PDF creates a PDF file of the measurement displayed and loaded at that time After you select this function a dialogue is opened in which the PDF file name and path can be indicated The storage path is the standard directory for the measurement record The standard name is the measurement displayed and loaded at present e g Measurement record C 70 350 m01 PDF file C 70 350 pdf 96 CID PRO 4 02 User Manual Section4 Program parts and functions 4 5 3 6 Zoom functions graphical measurement data analysis The zoom function enables you to enlarge an are
89. desired channel s value is changed in the selected line in the list In the chart the mouse points to the x The point should be displaced upward by t C You have the option of placing the mouse in the X direction time approximately on the point Thanks to the raster grid you have an area of k around the point to hit If you leave the area to the left or right you displace the point aside left or right The area does not quite reach half of the distance to the next raster line in each case Take note As when inserting a value line with the mouse you must also select the right channel when changing the line otherwise you will displace a channel that you didn t want to displace at all 66 CID PRO 4 02 User Manual Section4 Program parts and functions 3 Retroactively insert a values line Retroactively inserting a values line means that a channel s point is inserted between two other points the values line in the list is inserted between two other values lines The point will be created at this place on the graph and the connection adapted The mouse points to the x in the chart A new point should be created there You have the option of placing the mouse in the X direction time approximately on the point Thanks to the raster grid you have an area of k around the point to hit If you leave the area toward the left or right create a new point there if necessary The area does not quite reach half
90. e tion New test program File SEW ae A Ctrl N of sec 4 4 4 1 p 69 Open test program Es Open a CURG cf sec 4 4 4 2 p 69 D Save Ciri S Save as test program Save As X Ctrl A cf sec 4 4 4 3 p 70 Printer Page install Ctrl I Ac Print uu Print Graphic Ctrl G Print List Ctrl L Printer page setup and print cf sec 4 4 4 5 p 71 a Print Both Ctrl B Print Screen Ctrl T T Print as PDF Print Graphic as PDF bd Print as PDF Print List as PDF cf sec 4 4 4 6 p 72 Print Screen as PDF a Files last opened Open test program 4 4 4 2 p Exit x Ctrl E Exit the editor Edit Insert Line X Ins Delete Line X Del Edit lines insert change 9 lt Cut Line X Ctrl X delete cut and copy with keyboard menu functions 2 Copy Line X Ctrl C Cf sec 4 4 3 1 p 60 E Paste Line X Ctrl V Block copy insert F6 Block of lines Block delete F7 cf sec 4 4 4 7 p 72 Insert Start of Loop X Loop loop beginning and end Insert End of Loop X F3 OL 500 GAO P G Call Subprogram Call Subprogram S F4 ot sec 4 4 4 9 p 75 pe Conditional jump Insert Conditional Jump X F5 cf sec 4 4 4 10 p 76 Insert Program pr F10 ot sec 4 4 4 11 p 77 Refresh F11 Refresh the editor Templates Templates merece cf sec 4 4 4 12 p 78 Options editor Extras eH Options OAR cf sec 4 4 4 13 p 79 Delete test program x Delete Program Ctrl D cf sec 4 4 4 4 p 70 Gradient With Valued Calculation F8 Set Gradient
91. e C1D PRoO software entered test units can be assigned names This unit name can be freely entered into the configuration and changed cf sec 4 2 2 Configuration Communication page 36 If no name is recorded the default designation Test Unit xx is displayed xx stands in this case for the unit number If an active measurement recording such as sl Climate Cabinet has been started this measurement record can immediately be opened by left double clicking on the symbol for the test unit User Manual for CID PRO 4 02 21 Section4 Program parts and functions 4 1 4 Unit information In this area you can read off the unit s information for the selected and displayed test unit You can see the following information Field Significance Example Unit name default designation Name In the configuration Climate Cabinet U01 modifiable value cf sec 4 2 2 page 36 er Unit commission Commission Constant value read from the C70350 number test unit control Unit device type Unit type Constant value read from the C 70 350 unit control Climate Cabinet U01 C 70350 C 70 350 Information in this area is not changeable it is only for display 22 CID PRO 4 02 User Manual Section4 Program parts and functions 4 1 5 Unit and error status Test units status shows operational and error status Start Stop Operational status Symbol Status On clicking CO unit Is Unit will be stopped wm aft
92. e lead time can be entered directly if you want to provide a lead time ina loop A 1 is then shown in the start time field since a line assignment missing The current clock time and program start on the first line are defaulted to if program start time or program lead time line are not entered gt Start now and on the 1 line 114 CID PRO 4 02 User Manual Section4 Program parts and functions 4 6 4 Automatic mode Automatic operation starts after confirmation with Start all settings are accepted and processed and Back Automatic window is closed Display for the recording If you have started an automatic recording the selected test unit s background changes to pink in the unit overview display cf sec 4 1 3 Test Units page 21 Test Units VW Temperature Cabinet 1 fl Shock Test Cabinet p planned Test Unit Display for the starting time The test unit starts the program at the given time The unit status display changes depending on the kind of start time point immediately or later you have chosen cf sec 4 1 5 Unit and error status page 23 Start immediately Start later Automatic mode programmed starting time 15 00 07 09 2010 Ea OO O07 09020 10 Manual Mode h Take note Automatic recording shuts off automatically after the program terminates In contract manual recording cf sec 4 7 Manual measurement recording page 117 continues running after program term
93. e name will no longer match When the quick start selection is carried out both programs PC and unit programs will be completely evaluated and compared 1 Programs the same gt Unit program is started 2 Programs different gt User will be asked which program is newer and therefore which should be overwritten JE CID Pro Message The test program C 1CID PFRO 4 001zyklusyC 70 350 201 on your hard disk network drive differs of the test program C 70 350 201 memory location 1 in your best unit 1 Temperature Cabinet 1 Which test program would you like to replace E Unit gt PC PC gt Unit Unit gt PC Unit program overwrites PC program gt Unit starts PC gt Unit PC program sent again to unit gt Unit starts Cancel Cancel to check which program is more up to date User Manual for CID PRO 4 02 25 Section4 Program parts and functions 4 1 6 Program automatic CID PRO 4 02 software is running Program information is shown depending on which test unit you have Program 1 The display of the program automatic is changed while the i kid Ser 9 S Automatic S chosen and which operational state the test units have C 70 350 701 This includes Elapsed Time 00 21 31 hh mm ss probable end 10 08 2010 16 56h Program information line No Program no Program number in the controller Time lei 01 08 29 hh mm ss Program name Program name in the controller no loops active Elapsed Time Time ela
94. e or NO to permanently overwrite the selected existing file JE IS Save measuring attach measuring to existing file Wes No CID PRO 4 02 User Manual Section4 Program parts and functions 3 If possible enter a distinguishing comment for this program and consequently for the measurement You can describe the progression in more detail with the comment or insert special remarks 2 Recording of Climate Cabinet Test Unit 01 Comment at c CID PRO 4 00 messung C_ 0_350 m01 Recording of theProgram C_ 0_ 350 201 Recording Recording all seconds Save as 4 The recording rate Recording all seconds defines the time intervals at which recording occurs and is consequently critical for the recording data set For a test program with few changes it normally suffices to record every 5 minutes gt 300 seconds For programs with frequent changes a one minute or 30 seconds default value is quite sensible The exact information varies for each test unit and test program and can be set arbitrarily Please note The minimum value of the recording rate is dependent on the scanning rate in the configuration This interval only applies to the currently selected unit If you start further recording with another unit you can enter another recording interval there The recording principally has a very easy system defined tempo ral error which you can calculate out using the Excel conversion program cf sec
95. e unit the software will delete it and the unit s sub function is re enabled This list is helpful for obtaining an overview of the error in the individual test unit s controller It is needed under certain circumstances when it is not possible to fix all the errors in the unit but limited operation of the unit s sub functions is necessary Back closes the error list window again User Manual for CID PRO 4 02 129 Section4 Program parts and functions Error history reads an error history from the test unit Sak Error history of Shock Test Cabinet Test Unit 03 Error disappear Error disappear Error disappear Error disappear Error disappear Error disappear Error disappear Error disappear Waming appear Error appear Error appear Error appear Eror appear Error appear 08 05 08 05 08 05 08 05 auch 08 05 08 05 0805 08 09 08 05 0809 08 09 08 09 08 09 11 28 11 11 28 11 11 28 11 11 28 11 11 28 11 11 28 11 11 28 11 11 28 11 11 27 05 11 27 05 11 27 05 11 27 05 11 27 05 11 27 05 erortet motor protect compr C 03 21 motor protect compr PC 03422 voltage control 22 K1 motor protect lit 22421 Them Protect Fan cold space Them Protect Fan hot space 0 High pressure cooling 03 B40 High pressure pre cool 03 650 door is open 01 634 Power switch feed 00421 Ft 100 suct gas C 03 613 Fi 100 suct gas PC 03 619 sensor boiling pressure C 03 B Ft 100 suction vapour PC 03 B18 The occu
96. ection 9 Index Hardware key dongle 0008 12 Manuals Adobe Acrobat Reader 14 Licensing notes ar sauvnavennvennnvnnvvnnuvnne 7 Manual measurement recording Append a measurement 118 CYVCIC Storage sauser 119 Record Options ccccseeeeseeeeeeees 117 Recording all seconds 117 Start options Start at 119 Starting a recording eee 117 Stopping a recordmg 122 Ve d de 149 External devices rrrnanrrrnnrrnnnrnnnnrr 154 Network TC 153 Network Version Remote PC 154 Serial interface RS 232 rrrnennnr 150 Serial interface RS 485 0 151 Operating hours and event counter 123 Overview of all test units 55 Program start up SONE er 17 Ur 17 Software updates rnnnnnnnnnnnnnnnnnnnnennn 159 Software information ann00neaaann 160 Support section on the Internet 159 Special menus for particular test unit VPS 143 Starting test programs automatic 111 Append a measurement 112 Automatic mode 115 Comment 113 Display for the recording sa11 115 Display for the starting time 115 Programi ue EE 114 Program Gart 114 Recording all seconds 113 Recording the test cycle program 112 Selection the test cycle program 111 SET deet 114 Status overview Analogues channels annannennannann 31 Automatic quick start selection 25 Changing a set value
97. el s set Color and or actual value here the humidity and the 7 Setvalues respective colour Actvalues A selection of all possible colours dependent on Righi acle the windows system setting opens by clicking on the colour area Right click to select your desired colour The channel is not shown if you have Max 5 100 selected neither set nor actual value Y Min 0 By clicking the right scale this channel s scale is presented on the graph s right border the left side is the default This has the advantage that you have the correct scale for several curves on the right or the left and the printout is clearer If you only want to look at a particular area of your curve you can define this area with Y Max and Y Min The maximum values must be greater than the minimum otherwise the entry is ignored and the area not automatically adjusted to the curve With Delete you remove the check mark and the channel is not presented With Save the colour s is are accepted and the channel is presented on the graph check mark appears Take note If your definition of the various channels must proceed quickly you generate can define the default values which appear as follows default values Digital channel Value Colour Channel 1 ee Bad temperature Channel 2 M Yes Blue humidity Channel 3 M Yes Green Channel 4 M Yes Black Analogue channel Status Value Colour Set value M Yes Dark red Actual value M
98. ely stored and e conditional jumps jump to a selected target when a condition is fulfilled User Manual for CID Pro 4 02 57 Section4 Program parts and functions These individual lines are depicted on the graph large area The upper area the y axis IS reserved for analogue values and the lower area for digital values The x axis defines the test program s temporal progression Analogue value lines are connected by line value and time axis Digital states are displayed as bars Loops subprograms and conditional jumps are seen as coloured vertical markings SJE c CID PRO 4 00 zyklus C_70_350 Z01 o J e File Edit Templates Extra Help Comment 185 0 timi 897 400 are 180 0 Cursor t min 897 6400 1 C4 C tistd 14 95 1 67 Amin 170 0 dee 160 0 Time Temper Humidity deep deh Dig outp i in C in 150 0 1 0 75 0 140 0 2 30 75 0 3 oj 1800 130 0 4 180 180 0 120 0 5 Oj 750 110 0 6 180 75 0 7 o 70 100 0 i 8 60 70 0 90 0 I 9 o 750 i D p 75 20 0 10 60 75 0 E o 0 0 70 0 12 60 60 0 60 0 13 D 200 14 60 400 a 15 oj 200 40 0 i 16 60 20 0 30 0 az 0 20 0 18 60 20 Bri a 19 of 400 10 0 d 20 60 40 0 0 0 00004000e 21 0 60 0 22 E enn 7 10 0 D eee a M 20 0 Line 1 0 0 min 30 0 Time t min 0 Temper in C 75 00 D1 deepdehu 0 40 0 Humidity in rH 00 00 D2
99. er Address of E Mail Message Section4 Program parts and functions This option enables locking the unit s control terminal using a key icon in the status overview Take note _ Ifthe key icon does not appear even after restarting CID PRO 4 02 when the option is set then the connected unit does not support this function The unit s nominal value progressions can be given in the form of exp functions for special tests Several input fields are necessary in the editor to activate this function CID PRO 4 02 software can create an additional file to make message entries in the report file only error messages accessible to other systems These can be evaluated by another program The file s storage location can be given as Path and Name of Logfile If the error list cf sec 4 1 12 page 33 is not to be generally displayed in the Status overview in the event of existing errors warnings this option must be deactivated CID PRO 4 02 software can also send e mails to inform other systems or users of particular events The desired sender can be entered here A correct sender is prerequisite on several systems which even send e mails cf sec 4 9 3 8 E Mail message page 132 Selection of the unit text language of the texts stored in the controller In this Language i connection channel names among other things can be displayed in German of unit text or English Window Size CID PRO 4 02 software window sizes can
100. er confirmation unit off OFF Unit will be started Error status Symbol Status On clicking OK P Warning A warning cannot be acknowledged because the status is displayed for as long as the warning exists Attempt to acknowledge the error i ERROR Only operates when the cause of the error was removed User Manual for CID PRO 4 02 23 Section4 Program parts and functions If there is an error at a unit the error is displayed with the number of the test unit At the same time the unit is stopped and unit status is set to error shown in red Click on the button OK to close the error window e Sak Error Test Unit 1 Float switch waterbath 07 B80 LOK By clicking on the error button the error will be removed if it is no Status ON longer present regs If the button is no longer shown the error is no longer present and Automatic mod the unit continues to run error free On the other hand if the button stays visible and red then the error Is still present This unit s button stays red until all errors have been removed and acknowledged Take note Before acknowledging the error its cause must necessarily be checked out and removed In this example the unit only continues to operate if the Float switch waterbath error is removed It serves no purpose to acknowledge the error message if the error has not been removed The system can only operate again after the erro
101. est program for You only have available the analogue and digital channels enabled by the controller of the unit in question The active units e g unit 1 s configuration is therefore loaded during editor start up Two analogue temperature and humidity and three digital deep dehumidification digital output 1 and digital output 2 channels are available to you here in this example Unit 2 provided other channels again Editor layout is dynamic This means that the editor is updated when a different unit is selected SE Test Unit 1 NewProgram Z01 Lo e File Edit Templates Extra Help Comment DEBB DE 185 0 o e 180 0 er t min d 0 00 C istaj 0 00 H 0 00 min 170 0 160 0 Time Temper Humidity deep deh Dig outp E t in C in rH D1 D2 150 0 140 0 130 0 120 0 110 0 100 0 90 0 80 0 70 0 60 0 50 0 40 0 30 0 20 0 10 0 0 0 lle i r 10 0 ee 20 0 30 0 40 0 50 0 60 0 70 0 80 0 1 1 1 I U I 1 1 1 1 D 1 I 1 U 1 1 1 1 I I 1 0 5 DD B2 5 3 5 A0 5 3 5 H amp A SHS NW 5 9 5 100 10 110 115 120 t min deep dehu Dig outp 1 Dig outp2 Enter on the right a list of program lines that the test unit should execute into the area This list can contain e value lines lines in which selected digital and analogue values are defined e loops a command sequence that is multiply repeated e subprograms program parts modules which are separat
102. ethemet Scanning rate S Length of trendgraph IP Address 197 168 1 208 Serial Port Ethernet 8 Client Server Setting Ee Lot Client Server test communication FT ClientServer communication Configure Unit x Oo mmm Configure all Test Units WS Unit designation The unit designation is a freely editable characteristic designation for the selected test unit Enter a name location or something else here Test Units Climate Cabinet Temperature Cabinet 1 Scanning rate The scanning rate in seconds is the interval during which the selected unit is cyclically scanned Too small a value leads to unnecessary data traffic Too large a value leads to unpleasantly long CID PRO 4 02 reaction times Ten seconds is a good value in most cases The sampling rate is the smallest interval valid for recording measurement data measurement value recording always occurs in multiples of the sampling rate 36 CID PRO 4 02 User Manual Section4 Program parts and functions Length of trendgraph Change the trend graph s time axis length in the status overview The information is given in minutes Reasonable values lie between 60 and 120 min and can be modified depending on the test unit s task Serial interface Ethernet By selecting the appropriate selection box either parameters for the serial interface or for the Ethernet TCP IP become active Serial interface The serial interface denotes a digita
103. functions The zoom function enables you to enlarge an area You can repeat this procedure up to 19 times In other words you can zoom 20 times Proceed as follows to enlarge the desired area 1 Right click the desired area s upper left corner and hold the mouse button down 2 Now drag the mouse with the depressed right button to the desired area s lower right corner 3 The zoom function is applied after releasing the right mouse button and the selected area is enlarged Example for the above image 1 Click and hold time 6 min and temperature 110 C coordinate with the right mouse button 2 Drag the mouse with depressed right mouse button to the time 10 min and temperature 40 C coordinate 3 Release the right mouse button 88 CID PRO 4 02 User Manual Section4 Program parts and functions Take note The point connectors visible gradients can be displayed differently after zooming if the relation of the x to the y axis no longer agrees Checking the gradient by calculating the y segment length over x segment length shows that the gradient is in fact unchanged You can repeat this zoom process up to 19 times to et Bes SS These enlargements offer you the potential to e plot or translate points more precisely ji For example translating the point by 2K from ak 80 C to 82 C can now be carried out without gi problem e The result in the complete overview then et Se appears as follows
104. gram parts and functions Change user If you would like to retroactively assign other privileges to the new user mark the user you would like to change in the user list and click on the Change button The properties of the user to be modified are subsequently displayed e E User account Usemame e Admin time dependend loggout Loggout after min x D Rights apply to all test units Selection Rights apply only to selected units Rights Open editor Editor changes Open graphic Start programs Start Stop unit Switch digital channels Change set values Intemupt Programs Open configuration Open counter Change recording Open reports Use report functions Contin errors Lock unlock test unit control Et CID Wl WI Ei a a a a WI E CH Heart HH wm Now modify the user s name timed logout unit s assignment or privileges The modified settings are accepted with OK The user modifications are ignored with Cancel User Manual for CID PRO 4 02 51 Section4 Program parts and functions Change password If you want to change a user s password retroactively mark the user whose password you would like to modify in the user list and click on Change password Now enter the current password into the Old password text field in the window that appears If the password is correct you can enter a new password You must re enter your password to ensure that you havent mistyped The new password is
105. he appropriate colour This is then accepted Representation Representation relates to the form of the actual value curve The following options are available e Line Reg solid line e Points Ai US one thin point per measurement e Points big 0000000000 one big point per measurement e Points cross x XX XX XXX one cross per measurement Take note The defined actual value curves are temporarily plotted during program execution i e CID PRO 4 02 software does not buffer them or store them into a file They are exclusively displayed on the automatic graphic The temporary actual value curves are only shown during program operation Since only one test unit is always active in the status overview only the current unit s temporary actual value curves are ever shown insofar as this is desired Changes are accepted without OK confirmation load Settings Load the setting from the stored ptc file Save Settings Store the current setting into a ptc file Reset Settings Return the settings to the default settings ptc program temporary configuration CID PRO 4 02 User Manual Section4 Program parts and functions 4 2 4 Test specimen protection The selected unit channels for which software limits can be entered can be seen here Two value pairs are displayed for each channel These limits are predefined with the channel s Test specimen protection of Climate Cabinet Test Unit 01 minimum and maximum values The unit reports
106. ile in data pool cf sec 4 4 4 15 p 86 Save file as library cf sec 4 4 4 16 p 86 Delete Templates and Libraries Comment editor cf sec 4 4 4 17 p 87 Zoom functions editor cf sec 4 4 4 18 p 88 59 Section4 Program parts and functions 4 4 3 Generate a test cycle To enter a new test program s points you can place the desired points on the graph with the mouse or enter the values directly into the list 4 4 3 1 Edit lines insert change delete cut and copy with 1 keyboard menu functions Insert value line With the Ins key or the ES symbol a new value line is entered into the list This line contains the same analogue and digital values as the previous line except for time information This amounts to 0 after the insertion All values are 0 if you insert a new line into an empty program or after a loop a subprogram or conditional jump because no defined value is given here 2 Change line 60 This time as well as all other analogue values can be changed with the Enter key if the desired field is selected the field is then blue or by double clicking the left mouse button on the desired field A window now appears containing the old value This can now be changed or re entered The desired action is also shown above the new value to avoid errors Time in minutes is shown here Pressing OK accepts the Selection new value updating the graph and list if needed Pressing Back ignores
107. ill be sent SMTP Servemame JErVEMame Send configuration name a freely selectable Giele wi Receiver address receiver s e mail address SMTP server name Test unit errors or wamings consultation with the network Start Stop of CID administrator Unit number all units monitoring of a particular unit or of all On following conditions Change in programme status Change in digital channels units Change in analog channels Conditions File and configuration entries incidents triggering an e mail dispatch Communication emors Cyclic current status Cyclic instants triggering the e mail H dispatch and sending the current test unit s ven hour FILE status append actual measurefile monthly i weeny Back daily hourly The currently running recording can be 313 sendoptions optionally also sent along Name CI1D4 E Mail Test Back ignores the adjustments Ce eee Tee PSP OK accepts them gt but they are not yet activated SMTP Servemame mail cts de Unit No x 1 all units On following conditions Changing a send configuration Test unit errors or wamings You can adjust the existing send configuration Start Stop of CID by marking and change it Change in programme status Change in digital channels Back ignores the adjustments OK accepts them gt but they are not yet activated Change in analog channels File and configuration entries Communication errors Please note ee
108. in and temperature 40 C gt next point time 8 min 1 Gradient heating 5 K min Point 3 temperature 80 C 40 C 5 8 2 Gradient heating 1 K min Point 3 temperature 48 C 40 C 1 8 3 Gradient cooling 1 K min Point 3 temperature 32 C 40 C 1 8 4 Gradient cooling 5 K min Point 3 temperature 0 C 40 C 5 8 C 185 0 180 0 dk dh de A C 170 0 160 0 150 0 140 0 130 0 120 0 110 0 100 0 90 0 80 0 70 0 60 0 50 0 40 0 30 0 20 0 10 0 0 0 10 0 20 0 30 0 40 0 50 0 60 0 70 0 80 0 i i i i i i i i i i i i i i i i i i i i 0 1 2 3 4 5 6 F 8 9 10 11 12 13 14 15 16 17 18 19 20 t min 82 CID PRO 4 02 User Manual Take note User Manual Section4 Program parts and functions The controller tries to execute the specified gradient while the program runs Please check your given unit s max rate of change If the gradient in the program exceeds your test unit s max rate of change it wont be achieved Only two value lines may be edited If a line is not a value line e g the beginning of a loop the function will be cancelled with an error message If the value is calculating outside the permissible Y range e g temperature min max values the function will be cancelled The time between two points must not be equal to zero If you have pro grammed a jump the function will be cancelled with an error message This
109. in the controller and activated for viewing are shown on the display Digital Channels The two kinds of digital channels are Softkeys Indicators Softkeys These digital channels are switching channels that oe Humidiy execute permanently defined functions or actions S dl Softkeys are displayed and can be changed Dig outp2 _ Dewp gt 7C programmatically or manually The Softkey is set 1 or Drain Dewp lt 7C i reset 0 during program operation in the provided program For manual operation see Changing a Softkey next section deep dehu Temper Indicators These digital channels present digital inputs or functions whose current state can be displayed but cannot be changed Changing a Softkey In manual operation the Softkey is set by directly clicking on the grey square not active If the active test unit could confirm the new state the grey button changes its colour to green Click on the green square if you would like to reset this channel The green button returns to grey after unit confirmation e g the deep dehu deep dehumidification Softkey Click on the channel Click on the channel OFF 0 gt ON 1 gt OFF 0 Digital Channels Digital Channels Sofikeys Indicators Softkeys Digital Channels Sofikeys Indicators deep dehu Temper a H Indicators deep dehu 4 _ slemper deep dehu BW renner a sesf Dig outp 1 mich SE wee a p l P
110. ination User Manual for CID PRO 4 02 115 Section4 Program parts and functions 116 CID PRO 4 02 User Manual Section 4 Program parts and functions 4 7 Manual measurement recording Continuous saving of measured in data is activated in the manual measurement recording menu name of test unit currently selected in status overview is shown in the title Sak Recording of U01 Climate Cabinet Record options Recording all seconds enn Cyclic storage Time Er Date fe acivate acivate L i 4 7 1 Starting a manual measurement recording Record options The recording rate Recording all seconds defines the minimum time intervals which should separate measurement points and is consequently critical for the recording data set For a test program with few changes it normally suffices to record every 5 minutes gt 300 seconds For programs with frequent changes a one minute or 30 seconds default value is quite sensible The exact information varies for each test unit and test program and can be set arbitrarily Take note Minimum recording rate depends on the scanning rate in the configuration This interval applies only for this currently selected unit You can provide a different recording interval there if you start another recording with a different test unit In principle the recording has a very minor system dependent temporal error which you can compensate for with the Excel conversion program cf
111. ints Click on Time Temper Humidity deep deh Dig outp Temper in C ein rH Di D2 in C Click on Temper Humidity deep deh Humidity nt e in H gt D in rH The conversion occurs via the table column definition by which the editor shows what kind of point you want to create If you define a point after the conversion to humidity a blue point with a blue line is drawn on the graph and a value line is created in the list with the new humidity value In this case the last temperature value is copied i e the graph shows a temperature line with zero gradients and the list copies the last value If you try to create a point outside of the channel s permitted range it will be pegged to the minimum or maximum permitted value For example if you plot a humidity point lt 0 rH this will be pegged to zero Take note Time information in the list is always relative time between points User Manual for CID PRO 4 02 65 Section4 Program parts and functions 2 Changing a values line Changing a values line means that the temperature humidity or other value is changed If you want to displace the point laterally that is right to left you must make a time change in the line list If you want to change a defined point via mouse point the mouse at the new point x axis time is unchanged y axis value is displaced and double click The point is displaced vertically on the graph and the connection is adapted The
112. it s set values dont agree with the displayed values if the analogue channels are active in the subprogram The following call record is displayed following the marked line after confirmation with OK Call Prog 10 C You see a vertical turquoise line on the graph as a check indicating program invocation Subprogram application examples are the occasional rapid switching of digital channels in a long main program The subprogram can store a constantly recurring digital channel switching pattern The desired set value progression is now programmed in the main program The subprogram is inserted at the place where the digital channels are to be switched and only the digital channels are switched active in the subprogram Section4 Program parts and functions filename aktiv activate analogue channels in background program activate digital channels in background program call subprogram program no FA el 10 filename subprog 01 activate digital channels in background program If the digital channels are active in this subprogram they remain in the state they had on the subprogram s last line until a new line is reached in the main program So reset no longer needed digital channels at the end of the subprogram Take note 12 CID Pro Error User Manual for CID Pro 4 02 The file name of the sub program is with gt 15 signs too long If a program is loaded with a name that is too long
113. ith the Save function are all modified parameters stored and the configuration of the modified unit or units can be requested Take note Changing the unit number does not lead to the settings being stored Only with the Save function are the changes accepted in all test units The maximum admissible conductor length of 15 meters is to be observed for the RS232 connection 4 2 2 1 Help for adding Test Units into software To add a new test unit into the CID PRO 4 02 software please proceed as follows 1 Select the unit number 2 Enter an unit designation 3 Set the scanning rate in seconds 4 Select the type of communication a Serial parameters COM port Baud rate Parity Data bits Stop bits b Ethernet parameters IP address IP port 5 Test the communication 6 Save the entries 7 Read out the unit configuration from the controller 40 CID PRO 4 02 User Manual Section4 Program parts and functions 4 2 3 Program mode temporary transient display With this function the actual d values of the current units selected channel are temporarily i e transiently plotted on the automatic graphic Select the desired unit with the Unit No gt the channels which you can display during program operation are shown dimmed fps Here temper in C and humidity in RH Humidity in rH Program mode of Climate Cabinet Test Unit 01 A Unit No e E Actvalues display in the Program mode temp
114. k version If the software version which you have selected is already installed it will be updated if necessary for CID PRO 4 02 11 Section 2 Installation and system requirements 2 4 2 Driver for the hardware key dongle Follow the English software assistant s instructions Please select Custom during setup type selection Te Sentinel Protection Installer 7 4 2 InstallShield Wizard Setup Type e p o Choose the setup type that best suits your needs Protection Installer All program features will be installed Requires the most disk space Choose which program features you want to install Recommended for advanced users Cancel Select only the Sentinel System Drivers parallel and USB System Driver and deactivate the two other entries by left clicking on the entry Confirm with This feature will not be available Follow the additional instructions Te Sentinel Protection Installer 7 4 2 InstallShield Wizard Custom Setup Protection installer Select the program features you want installed Click on an icon in the list below to change how a feature is installed E Sentinel System Drivers jana en rm Gr Parallel Driver The network license manager for i 2 l protected applications with pr USB System Driver Sentinel Hardware Keys M Sentinel Protection Server FE sentinel Keys Server This feature will be instal
115. k the desired line You get a context menu if you now click the right mouse button Here you can select display line to pop up a window displaying the line s entire content at GE display line gt CID user accounts not active or TCP connection to test unit 3 IP adr 192 168 1 209 established insert line You have the additional option of inserting comment lines into the report via this context menu IS Report comment entry display line gt Comment belongs to test unit no Comment You can insert a free text explanatory comment in the comment field e g power failure at the PG The list displays user entered report lines are displayed in blue If the test unit number is given as 0 zero the entry is not assigned to any particular test unit but to the entire system 09 09 10 10 06 21 Power failure at the PC With a unit number greater than 0 zero e g 1 the entry is assigned directly to this test unit 05 09 10 11 09 03 01 Start of the Test Sensor ABC In this way lines inserted via the context menu can also be deleted again No confirmation prompt appears however display line insert line delete line Take note Deleted comment entries are irrevocably lost 126 CID PRO 4 02 User Manual Section4 Program parts and functions 4 9 2 Buttons Key Menus Symbol Submenus combi Reference nation New report File Sew ll o sec 4 9 3 1 p 127 Load report L
116. keyboard In this connection any arbitrary admissible date within a year can be entered The time must conform to the hh mm hour minute format The entry is ignored if the prescribed formats are not adhered to lf a time is entered prior to the current time having thus already passed the current clock time is assumed gt so first change the date then the clock time The current date is assumed if an incorrect date is entered Starting time 15 00 Starting date 97 09 7010 Start options 0 Start now Start at Take note Check the current system date Cyclic storage Cyclic storage make sense if you have extremely large datasets or you want to have for example a measurement file completed daily during a very long test cycle A window opens to specify the cycle interval if you activate this function Cyclic storage Cyclic storage Time gt Date activate Record options Minutes lin Neat storage date at 07 09 2010 around 13 00 File format User Manual for CID Pro 4 02 119 Section4 Program parts and functions 120 The following time intervals are available to you Time Storage options interval ger Time interval houry Record options 5 by the minute Hours Minutes hourly SEN minutes 00 05 10 15 Next storage date at 07 09 2010 around 13 00 NE max 60 days dail Record options KE NO of days by the hour
117. l input and output for a computer or a peripheral device During serial data transmission bits are transmitted one after another along a single conductor The following parameters must be set for the serial port Default values COM port PC interface 1 Baud rate unit of transmission speed 19200 Baud Parity erroneous information transmission odd parity detection Data bits transmission occurs in words 8 data bits word gt 5 to 9 bits Stop bits up to two stop bits are used 1 stop bit because of synchronization Ethernet Ethernet is a wired data network technology for local data networks LANs Local Area Networks They enable data exchange in the form of data frames between all devices connected to a local network computer printer CTS units and the like Assigned addresses must be unique In other words a selected IP address may not be assigned a second time within this network The desired units IP address as well as an unused IP port number are necessary for communication over Ethernet Entry at the unit via Mainmenue 2 3 gt Settings gt Network Take note Your network administrator assigns IP addresses as well as subnet mask and default gateway within your network IP address unique unit address 192 168 1 90 IP port port number in the suggested range 8001 8000 to 8050 Please note Sensible numbering IP port 8001 for unit 1 IP port 8002 for unit 2 etc User Manual for CID Pro 4 0
118. led on local hard drive JE This feature and all subfeatures will be installed on local hard drive This feature will not be available Install to aa 12 CID PRO 4 02 User Manual 2 4 3 ASCII protocol test program Section 2 Installation and system requirements 2 43 1 ASCII protocol for the serial interface This test program offers you the option of checking the serial interface communication with the test unit using a couple of mouse clicks Unit address PC interface Communication Left area Possible commands Display mode possible commands received characters ChanelNo 0 actvalue ChanelNo 0 actvalue ChanelWo 0 actvalue ChanelNo 1 actvalue ChanelNo 1 actvalue 4 Must agree with the address set at the test unit Serial COM port which is connected with the test unit red no communication green communication OK Status selection sent and received character Selection of all commands which can be sent to the equipment Display of characters in plain text see figure or in actual transmitted bytes fead analogue values sl Display mode all transfered bytes SE E encoded 079 3 setvalue 079 3 setvalue 073 3 setvalue 008 6 setvalue 008 5 setvalue 040 0 020 0 020 0 010 0 010 0 User Manual for CID Pro 4 02 Communication Chamber adresse ae PC Port Slcom3 Transmit On OR 13 Section 2
119. lready open file is only executed with an additional confirmation prompt to avoid overwriting the template by mistake lf you want to change the template in the CID installation pathizyklusisample directory open the template as previously described change it and use the Save as function to store it with the same name in the sample directory An additional confirmation prompt serves to prevent important templates from being accidentally overwritten Take note Unit X templates are only visible in the editor when unit X was selected before opening the editor or when a new program is selected CID PRO 4 02 User Manual Section4 Program parts and functions 4 4 4 13 Editor options General Expand all loops Editor line delete without secunty query Back OK Expand all loops If this option is set and loops are used in the generated test program the loops are displayed one after another corresponding to the stated number This way the correct nominal value progression can be monitored especially within the scope of the jump to the beginning of the loop and after loop completion If this option is not set then the graph shows only one iteration through the loop KA pn wei Loops are displayed se Expand all loop 0 differently for identical Sg gt one loop iteration programs raai mo 100 05 i eno Ser Ek NETTET pn H i lom A D d 1 EH a K E Expa
120. ly Forward more v s Move Translate Zoom amp Junk Fe S More A Team E mail B adtions Follow Up D Select Delete Respond Quick Steps Move Tags Editing From CID Message cts umweltsimulation de Sent Mi08 09 2010 11 49 To info cts umweltsimulation de Ca Subject CID Errormessage CID4 E Mail Test Climate Cabinet Test Unit 01 C70350 C 70 350 Error Float switch waterbath 07 B80 Date 2010 09 08 Time 11 48 52 a Test unit no 01 Test unit name Climate Cabinet Commissions No C70350 Test unit type C 70 350 Message Error Float switch waterbath 07 B80 RY CID Message cts umweltsimulation de a 134 CID PRO 4 02 User Manual Section4 Program parts and functions 4 9 3 9 Options event logs The report file display is adjusted with the options You can filter out the messages which you do not want to see or check mark messages which should be displayed S Options Channels dl Analog d Digital st Programs PC Actions dl Configuration CID protection mA mechanism of security Service dl Service Files MV CID Pro Counter Fl Counter actions Communication Emor dl Interface Eror messages vw coloured Waming messages Idien i All Starting date 0109 10 Starting time 03 05 Ending date 08 09 10 Ending time 11 29 By deactivating individual entries like analogue channels they will be filtered out The report files display making the
121. m x Time Example with start line 2 time 2 min and temperature 40 C gt Next point line 3 temperature 50 C 1 Gradient 20 K min gt Point3 time 2min 40 C 20 K min 2 Gradient 10 K min gt Point3 time 4min 40 C 10 K min 3 Gradient 5K min a Point3 time 8min 40 C 5 K min 4 Gradient 2 5 K min Point 3 time 16min 40 C 2 5 K min d t min 84 CID PRO 4 02 User Manual Take note User Manual Section4 Program parts and functions The controller tries to execute the specified gradient while the program runs Please check your given unit s max rate of change If the gradient in the program exceeds your test unit s max rate of change it wont be achieved Only two value lines may be edited If a line is not a value line e g the beginning of a loop the function will be cancelled with an error message The values e g temperature between two points must not be equal to zero If you have programmed a horizontal straight the function will be cancelled with an error message This approach also applies to the retrospective editing of the test pro gram In other words you have defined two points e g temperature value and time which you now wish to adapt If you select the last line as the start line you will also require additional information about at which value e g temperature the ramp should end The value field e g temperature
122. ment files which Microsoft Excel can read and display can be converted into ASCII formatted text files using the new conversion program CID Measurement file gt gt Microsoft amp Excel Ver 2 2 This program can be started in two ways 1 Inthe graphical measurement data analysis via the menu entry sz Extra gt Convert to Excel Program 2 By starting the CID installation pathiconvert exe program D 9 in the program manager windows explorer Ce The conversion program starts after carrying out one of the two actions Convert CID Measurement File gt gt Microsoft Excel Ver 2 2 fle CACID PRO Mmessung Measurement Filename ta me kon C 70 350 m01 e 09 05 2008 09 45 10 rell vFeuchte FE Taup gt 7C CID Messung 2010 09 02 11 29 53 m01 HI w Taup lt 7 C CID Messung 2010 09 02 15 48 26 m01 09 08 2008 11 35 33 Tiefentfe CID Messung 2010 09 02 15 58 28 m01 Dig Ausg CID Messung 2010 09 02 16 32 01 m01 No of Lines 7807 IC w Dig Ausg2 CID Messung 2010 09 02 16 41 19 m01 wl Abschlaem Badtemper No of Channels Siededruc mess mi Analogs Siedetemp w Vert Digitals Comment at C_ 0_350 m01 Interpolation to fixed time period time period E sil A list of all measurements stored in the selected directory here C CID PRO 4 00 messung in the upper left can be seen in the program s left area All measurement files are shown here and not just particular test uni
123. mputer or send individual programs directed to the controller Programs stored on the selected unit are listed with Read proglist of contr The marked program can be uploaded and stored on the PC The file path and program name are still queried Prog to uni Using send a program can be selected on read the PC and ultimately transmitted to the controller This option is only possible in relation to controller s software version starting with V1 62 User Manual for CID Pro 4 02 81 Section4 Program parts and functions 4 4 4 14 Set Gradient The extra option Gradient helps you further if you want to create programs with exact gradients from point to point 1 With valued calculation E duse tat oe You determine the y coordinate of the next point e g Fie of line oF temperature value with the specified duration and desired gradient using value calculation Gradient You mark the line in the value list that you want to serve est 10 K min as the starting point for the defined gradient Then you i al activate the Gradient with function in the Extra menu j or the F8 key You can enter the settings for the defined gradient in the following window Rise of line Gradient starting point Heat positive gradient in K min gt 0 Cool negative gradient in K min lt 0 y Temperature General calculation Gradient m x Time Example with start line 2 time 2 m
124. n Settings Number of test units page 35 are all listed with designation of the unit s name and number e g U01 Climate Cabinet wv U01 Climate Cabinet 102 Temperature Cabinet 1 w 1103 Shock Test Cabinet wv U04 Temperature Cabinet 2 1105 planned Test Unit All test units are checked on by default i e shown here Select a test unit in the menu if you want to hide it in the visualization The unit will no longer be displayed gt Check mark in front of entry is no longer set Test units that are not configured are not checked on and there is no possibility to change this state 142 CID PRO 4 02 User Manual Section4 Program parts and functions 4 11 Special menus for particular test unit types 4 11 1 Temperature Shock Test Cabinets The shock test cabinet is a special test unit type in which very fast temperature changes can be created The temperature changes are not achieved by changing a zone s temperature but by moving the test specimen from one temperature zone to another Its own menu is provided for this special function With its help test programs can be created for this test unit type 4 11 1 1 Overview menu Program data Name Standard pre temperature temperature hot chamber hot chamber difference russ 7 cycle counter Med ee de S TITT aaa 214 iL temperature pre temperature temperature cold chamber DI 60 cold chamber mob cradle difference W 1000
125. n the configuration cf sec 4 2 5 Configuration Generally page 44 of all participating PCs With access to the config files on the network it is ensured that all PCs will have the same unit s settings The correct server config file e g KONFIG KO1 in the CID Pro 4 02 installation directory must be copied to the client if no network directory is specified Without a config file the software cannot display the unit s setting The unit is then considered to be not connected although communication functions in practice This way the client now also has access to already completed measurement records Besides test programs can be provided on all PCs If a test program is already running on a unit the graphical program preview can also be activated on the client selecting ASCII Server enables a scan of current values on the selected test unit with in house software You can get the data records description for this special application from the CTS hotline CID PRO 4 02 User Manual Section4 Program parts and functions Test communication To ensure that the displayed communications parameters for the selected test unit were correctly entered the connection is checked with exactly these parameters If a connection can be established the affected LED illuminates green if not it stays grey Configure Unit x A unit s configuration contains all the information displayed in the CID PRO 4 02 software This includes analogue and
126. nctions 4 5 3 15 Settings The complete settings of the graphic display are saved in one setting That means settings for example in the options analogue and digital channels and their presentation are stored in the setting Different settings can be defined for various purposes depending on what should be displayed These settings can only be switched with a click of the mouse The procedure to create new settings is as follows e Setting 1 is the Start setting which is present from the start and cannot be deleted e Define the presentation of the graph in Options e g number and presentation of the analogue and digital channels or the real time display etc e Select in the Settings menu the New Setting entry to create a new setting gt the presentation of the graph window is reset to the standard settings e Now define the presentation of the graph for the 2nd setting in Options e g number and presentation of the analogue and digital channels or real time display etc e Now select other settings and options that are useful Various settings are briefly described as follows 1 Setting Temper Humidity 06 00 08 72 10 05 2008 2 Setting Default Setting RL EH gt ma Pxas 28000 PXas 28 000 ma in i ri es i j A L Lech ma VT I j ES ie i ji y E j PI J NY I N IH d LU H HSA OL WM iii H AV II CG It BG Nu EE z
127. nd all loop 1 Si gt 6 loop iterations i Tag m a i 7a asi ER 250 pp a 505 4 L Aa L ea ge aid I 10 0 app ae 1 I j gg ee ee dei de de di we air van mo EM AE eee Editor line delete without security query If you have created a program and perhaps need to delete many lines you have to deal with the confirmation prompt at every line If you are sure that you havent made any mistakes or it is not serious if you delete a line by mistake set this option delete without security query and you can delete the line without the query User Manual for CID Pro 4 02 79 Section4 Program parts and functions Sealing As y axis scaling you can select whether the same value range applies to all channels The scale is always the same in this case It E i same scale for begins with the smallest and extends to the dink greatest value of all the analogue channels l 0 separate scale In the second variation each channel receives for each channel its own range If the active channel is switched the scale changes accordingly and the area presented on the graph switches This way you have the option to set the area for each channel resulting in maximum resolution Time Axis Enter the new time axis here The maximum CursorNet value for one thing how wide in minutes for example should the time axis be and the units seconds min
128. nd select Software resp Programs and Features Please select CID PRO 4 02 from the installed software list and click on the Remove resp Uninstall button en Gr E e All Control Panel Items Programs and Features Control Panel Home Uninstall or change a program View installed updates To uninstall a program select it from the list and then click Uninstall Change or Repair Se Turn Windows features on or SN Organize Uninstall Install a program from the network Name Publisher Installed On 12 CID Pro 4 02 CTS GmbH 06 05 2013 Bloe m 7 1 CTS GmbH Product version 4 1 4 Help link http wwew cts umweltsimulation de Confirm uninstall of CID PRO 4 02 CID PRO 4 02 is now removed from your system All files installed while working with CID PRO 4 02 like programs measurements report files initialization files as well as personal settings remains during uninstall They can be re used during re installation into the same installation directory If you dont need any of them you can delete all files inthe CID PRO 4 02 directory after uninstall User Manual for CID Pro 4 02 15 Section 2 Installation and system requirements 16 CID PRO 4 02 User Manual Section 3 Program start up 3 Program start up 3 1 Software Click on Start gt All Programs gt CID PRO 4 00 gt CID PRO 4 02 3E or ml 13 La A on a short cut CID PRO 4 02 on the desktop During FIRST program start up you di
129. ng al hourly add die A correct sender is precondition on some E systems cf sec 4 2 5 Configuration append actual measurefile Generally Options Sender Address page 44 Back You can get the name of your SMTP server from your network administrator User Manual for CID Pro 4 02 133 Section4 Program parts and functions Deleting a send configuration You can remove a selected send configuration by marking it and using Delete Take note Deleted send configurations are irrevocably lost Activating and deactivating a send configuration You can use Activate to activate the marked send configuration The send configuration is displayed in green script Several send configurations may be active Take note Selecting certain send configurations can cause a large number of e mails can be dispatched This information flood can be unpleasant for the receiver Example of an e mail message for a test unit error Subject CID Errormessage CID4 E Mail Test Climate Cabinet Test Unit 01 C70350 C 70 350 Error Float switch waterbath 07 B80 A y CD Errormessage CID4 E Mail Test Climate Cabinet Test Unit 01 C70350 C 70 350 Error Float switch waterbath 07 2 amp 3 gt 8 a Move to 1 P Rules Mark Unread kV Find Ignore gt Fal Meeting NEDE d lp Rule ENER dg d Fin ve Ca To Manager NI OneNote Categorize 7 E Related je Delete Reply Rep
130. nits e 13 Visualization Close Extra Units i D D nO tee e z Ze N y ar ah Sitzgruppe D Fy a d As i Sitzgruppe i 4 10 2 Buttons Menus Symbol Close Extra ZS Units User Manual Wand aus Leuchtwirfeln Submenus Configuration Load Settings Save Settings Reset Settings Units for CID PrRo 4 02 Test Unit 03 Shock Test Cabinet TSS7013 TSS 70 130 Analog Channels Key combi nation Ctrl C Ctrl L Ctrl S Ctrl R Pflanze Reference Exit visualization Configure setting cf sec 4 10 4 1 p 139 Load setting cf sec 4 10 4 3 p 142 Save setting cf sec 4 10 4 2 p 141 Reset setting cf sec 4 10 4 4 p 142 Test unit display cf sec 4 10 4 5 p 142 137 Section4 Program parts and functions 4 10 3 Display the Visualization Each unit possesses a unit designation here U01 Climate Cabinet and a coloured frame indicating the test unit s Status VOL Climate Cabine Various unit types are presented on the right side This status description is analogue to the units presentation in the status overview cf sec 4 1 3 Test Units page 21 Moving the mouse over the test unit displays the most important information Test Unit 01 Climate Cabinet gt C 70 350 Analog Channels Sottheys Indicators T Se 50 0 in At 432 Humidit s 0 0 nH as Si Waterta 150 in I At 150 Humidity Dewp gt
131. nnnnr 35 Access Configuration In operation 53 Access Configuration Settings 48 Adding Test Units rrrnnrornrrnrnrevnnnnnn 40 Administrator settings 000 49 Change D sewornd 47 52 Change user 51 Client Server Setting ccccceeeee 38 COMMUNIC AT ON BEE 36 Configure all test units 06 39 Configure Untx 39 Default Directories rrrnrrnnnrnnnrnnnnnnn 44 SEET E 37 Generally EEE 44 MEET ann 50 Beie 35 Length of Irendgraph ER Number of test umite ees 35 UE 44 Eeer 54 Program mode 41 Scanning rate sassari 36 Serial mtertace 37 SENO EE eer eet ae eee eee 35 Simple Password 46 Test Commupntcatton 39 Test specimen protection 0 43 Unit designation nannnennanneennennennnni 36 User logoff rrrnrnnnnrennnrrnnrnvnrennnnennn 53 User logon ccccseccseeeceeeseeeeseeeeees 53 Windows Ge 45 End user license agreement Copyright MEMO rrrnnnrnrnnnrnnnnennnre 161 License agreement nonnnnnnnnannnn 161 Place of fulfilment place of jurisdiction applicable Iow 162 EI EE 162 Event logs reports srrrnnvrnnnvvnnuvnnn 125 Activating a send configuration 134 Sue E 127 Changing a send configuration 133 Comment mes 126 Delete report 127 Deleting a send configuration 134 User Manual for CID Pro 4 02 Section9 Index Display line annannnnnannannnnnnnnnnnnnnenne 126
132. nsennee 117 4 7 1 Starting a manual measurement recording arrrrnnrrnrnnnvrnnvrrnnrernnrrrnnerennnsen 117 4 1 2 Stopping a manual measurement recording rrrrnrrnrnnrvvnnrrvnnrennnrrnnnnrennnnen 122 4 8 Operating hours and event Coumter 123 4 9 EE es S 016 EE NE O 125 4 9 1 EE RENEE EE EE 125 4 9 2 BUROO aeee E E E EE E 127 4 CID PRO 4 02 User Manual Section I Table of Contents 4 9 3 Event log Tunchong s nnennennennennenoensnesrrsrrnnrsnrnnrsrrnrrnrrnrrrrrrrrnrrrrrrerrerrereerne 127 4 9 3 1 NR Lu kAl arna peer 127 22 NNN 127 REE DN E EEE EEE EN 127 ASA PROPO eene 128 2005 EPO Trep ei E ae teaaiouneiem latent Ne 128 AISO EE 129 4 9 3 7 Power NEE 131 4 9 3 8 E Mail E e LN 132 4939 ENN Jian 135 ANG VENN 137 4 10 1 Per 137 AMO EON GE 137 4 10 3 Display the Visualization rernrennrronnrennrrnnnrernrrnnnrennerennernnernnrennernnnrennrennee 138 4104 VETT 139 4 10 41 Ce SCTING EE 139 EE due EE 141 41043 BM 142 21044 REE SoNg E 142 4 10 4 5 Display Test Units rerrrnnrrnnrrnnrrvnrrvnnrnnnrnnnnvannnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnrnnnennee 142 4 11 Special menus for particular test unit types ee cceseeeeeeeeeeeeeeeeeeeeeseeeeaeeenees 143 4 11 1 Temperature Shock Test Cabinets n nennseennseennserrrnnerrerrrrnerrrenrrrenr nnen 143 e Ke VON 143 1212 FE res 144 LEG Ga 010 12 1 1 EEE a 146 4 11 1 4 Test program Creation rarannnrnnnrnnnrnnnrnnnrnnnnnnnnnnnrnnnrnnnennnrnernn
133. nstalled The installation the manual the quick start guide and the driver for the hardware key are displayed when you click on the button CID Pro 4 02 CID PRO 4 02 User Manual Section 2 Installation and system requirements ASCII Protocol test program The test program for the ASCII protocol installs an application with which you can investigate transmitted data based on this protocol This can be helpful when you control the test unit using your own software and want to try out the necessary commands and data for this Adobe Reader Acrobat Reader is needed to be able to display the documentation also located on CD in electronic form Quick Start Guide PDF The Quick Start Guide describes all the important standard functions in two pages Driver for the hardware key dongle Your computer system needs the driver in order to recognize the USB dongle Manuals Manuals in the respective languages as PDF format User Manual for CID Pro 4 02 9 Section 2 Installation and system requirements 2 4 1 CID Pro 4 02 Follow the software assistant s directions after you have started the installation CID Pro 4 02 It rs strongly recommended that you esit all programs before running this installer Applications that run mp the background such as virus scanning utilities might cause the installer to take longer than average to complete Please wait while the installer initializes Cancel During the inst
134. nts for channel display and evaluation You have the following options when exiting the options Back The options window is closed without accepting the changes temp The changes are accepted but not saved for this measurement s setting This means that the measurement will in fact be displayed as desired but these changes are no longer available when reopened OK All changes are permanently saved via file and are available to you when the measurement data analysis is reopened or CID PRO 4 02 is restarted Ge Ce Ce Channel Click to select the analogue and or digital channels that you want to see on the graph By clicking you have additional selection options in the window that appears for this channel Wl V asservor wi Tempul Temp Ablut Digital channel FeuchteZu FeuchteAb Taupunkt Abschlaem Badtemper Siededruc Siedetemp H Verlues Leben KR Saugdrk t Saugd K generate default values This window appears by clicking a digital channel The colour in which the channel Temperature in this case is to be represented can be selected here With Delete you remove the check mark and the channel is not presented With Save the colour is accepted and the channel is presented on the graph check mark appears 100 CiD Pro 4 02 User Manual Section4 Program parts and functions Analogue channel This window appears by clicking an analogue ih Feuchte channel Here you can select this chann
135. oad Di of sec 4 9 3 2 p 127 Delete report x Delte Ctrl Del 2 sec 4 9 3 3 p 127 m List 2 Print SA completely Ctrl C A List completely as PDF Print report List CtrlaF Ch Sec 4 9 3 4 p 128 filtered G List filtered as PDF List Ebbe completely Export report List cf sec 4 9 3 5 p 128 filtered p Exit Ctrl E Exit the event logs i Error list Error list cf sec 4 9 3 6 p 129 Power fail Power fail cf sec 4 9 3 7 p 131 E Mail E Mail message message cf sec 4 9 3 8 p 132 Options event logs Extras gt Options Ctrl 0 cf sec 4 9 3 9 p 135 Help EA Help F1 4 9 3 Event log functions Here you can carry out the following report file actions 4 9 3 1 New report Generate a new report file CID PRO 4 02 sets up the file name and chooses the current date If a file already exists it is chosen as active all actions are appended or the file is regenerated all previous entries are lost in the process 4 9 3 2 Load report Load a report file from the CID installation pathireport subdirectory and display it with the restrictions of the Extras gt Options submenu cf sec 4 9 3 9 Options event log page 135 4 9 3 3 Delete report No longer needed report files can be deleted here You must confirm the deletion with a confirmation prompt Take note Deleted entries are irrevocably lost User Manual for CID PRO 4 02 127 Section4 Program parts and functions 4 9 3 4 Print
136. ollows CID installation pathlzyklustss cycl e g CACID PRO 4 00 zyklus tss_cycl Clicking OK transmits the selected program to the desired program location in the controller and started Clicking Back interrupts the operation Take note test program possibly already stored there is overwritten 146 CID PRO 4 02 User Manual Section4 Program parts and functions 4 11 1 4 Test program creation Clicking the button opens a window for the simple entry and storage of shock test cabinet test programs IS Shock Test Editor Filename lt unidentified gt waitfunction activate upper PT 100 activate lower PT100 above free FT100 below free PT100 tolerance 3 0 K tolerance 3 0 K pre temperature a hot chamber difference 170 0 C 10 0 K Vi Wait for zonetemperature after programstart temperature cold chamber pre temperature 50 0 C cold chamber difference 10 0 K hot period GU min 60 min Cycles programmed 9999 Start in cold zone The shock test editor shows an image similar to the overview of the programmed shock test program For this form of input a normal test program is created in the background which can be reworked with the editor cf sec 4 4 Test cycle program editor page 57 for special requirements e g switching digital outputs This is not necessary in the default case The entry allows very quick and clear test program creation for the shock test cabinet
137. orary Temper in C gege Load Settings Save Settings Reset Settings Check marking Actvalue display in the program mode temporary activates the function gt channel names are activated and can be individually selected Program mode of Climate Cabinet Test Unit 01 Unit No e E Temperin C CT Humidity in rH Line After activation of an individual channel here Temper in C the channel s settings are also activated Program mode of Climate Cabinet Test Unit 01 Unit No i 1 di Actvalues display in the Program mode temporary ia M in Humidty in rH User Manual for CID Pro 4 02 41 Section4 Program parts and functions These settings relate to the colour of the curve and the representation m Program mode of Climate Cabinet Test Unit 01 Unit No be 1 Actvalues display in the Program mode temporary timo M ine z O TT eee rer fett He ee Points hin TT ee LGS Bo an CH noo CR CR Points big FT et Tee I II Points cross Colour By default the colour is displayed like the actual value colour in the channel s status overview but a tone lighter e g pink instead of light red and turquoise instead of light blue cf sec 4 1 10 Analogues channels page 31 You can arbitrarily change the actual value curve s colour by clicking on the colour field and selecting t
138. ositions of the digital channels have changed The program is adapted to the actual test unit configuration You are saving the test unit 1 program for another test unit Please confirm that number and position of analogue and digital channels are equivalent 4 4 4 4 Delete test program You can select several files at once here to remove no longer needed test cycle programs Confirm your selection with Remove All You ultimately delete all the files you selected after activating OK in the confirmation prompt Take note Handle deletion with care Deleted files and data are irrevocably lost 70 CID PRO 4 02 User Manual Section4 Program parts and functions 4 4 4 5 Printer page setup and print You can print out the created test cycle program In the process you have the option to select the test program s graph cf point 2 the test program s list of values lines cf point 3 both graph and list together cf point 4 or the display screenshot cf point 5 Besides you can still make printer settings cf point 1 1 Printer page setup You have the following options after opening printer options Graph If you want to print out the graph you will be queried for the printer and settings If you want to address your default printer with unchanged settings set the option to circumvent querying the printer List e Print format Set your format to portrait landscape or printer settings e
139. pdf 4 4 4 7 Copy insert a block of lines delete a block of lines You can not only copy cut and or insert a values line but also a complete block of lines 12 CID PRO 4 02 User Manual Section4 Program parts and functions 1 copy and insert The following window opens after clicking on the Block See copy and insert function F6 key t 4 z Temper Humidity in C in rH 0 75 0 0 0 0 al 750 09 0 0 0 deep deh Dig outp a D1 D2 IS Block copy insert oj 1800 og 180 1800 00 180 og oof 00 sof og 00 o eg oo of sai oo al en 00 to Copy line FA ve and insert after line 1 2 3 4 5 G H 9 In the process the lines to be copied from yellow through pink and the line after which the block is to be pasted light blue are colour coded The list is adjusted and updated if information is changed 4 S A EA EA A A A GB any line can be selected lt 10 always lt as Gs Take note The copied block is inserting after the selected line 2 delete The following window opens after clicking on the Block Time delete function F7 key t 14 z Temper Humidity in C in rH 0 deep deh Dig outp D1 L 0 50 75 0 on C3 C3 Sak Block delete ca 4 ci 180 1800 0 180 260 10 to Delete line zl a on de Ra GT C3 60 70 0 75 0 Sls SS ENEE EEN LD Co rl i i oe as
140. psed since starting Channels set values Format hh mm ss Temper 750 hours minutes seconds Humidity 0 0 arr Probable End Time calculated to program completion per Take note If you start a test program with a wait function i e that a channel s nominal value waits for the actual value within a particular tolerance then the end of the program cannot be exactly calculated The time is calculated without wait functions and is constantly updated based on the number of wait functions and their actual durations Line information Line No The line number on which the program currently finds itself Time Left the line Execution time remaining on this line Active loops Are loops still active Number and completed repetitions are shown for active loops Set values of Individual channels The set values of the first four analogue channels of the current line are displayed continue Button to interrupt or continue the test program The test unit is set to interrupt status display continue if an error exists Now the program can only be restarted after the error is fixed If you have saved comments during creation of the test cycle program these Ca are displayed with this button The comments are only for display and cannot be changed The rotating disk in the upper right hand corner shows whether automatic operation is running If the disk is grey the test program is interrupted e g because of a pau
141. r has been removed and acknowledged If there is a warning at a unit the warning is displayed with the number of the test unit At the same time the unit status is set to warning shown in yellow Click on the button OK to close the warning window 2 Warning Status Test Unit 3 install coniprassed air 19 564 Start r Stop Sg d Instill eommresserd ar 100263 Take note When the cause of the warning has been removed the warning will generally be cancelled automatically 24 CID PRO 4 02 User Manual Section4 Program parts and functions Yellow signal Text output about automatic operation status Automatic mode Status Automatic mode Interrupted Automatic mod ntsanptsd Programmed start time 14 30 08 08 2010 Selection field Manual Mode automatic quick start selection If the unit is stopped i e it is not running right now clicking on the selection field opens a list of all programs that are stored in this unit s controller During selection of a program and activation of the start button this program is started in automatic mode without going through the automatic menu Normally a created test program is loaded to the selected unit controller and started if necessary via the Automatic menu If you now want to carry out changes to this program whether in the GID PRO 4 02 editor on the PC or in the unit editor the PC program and the controller programs with the sam
142. rectly find yourself in the software s program settings cf section 4 2 Configuration CID Pro 4 02 Settings page 35 Before you can work with the program you have to define how many test units there are how the test units are connected to the software and at what interval they are to be queried At all subsequent program starts the software independently searches for test units on the basis of these settings and if the test units are switched on retrieves the current unit data If the test unit configuration is not available it is read in by the GID PRo software If no communication can be established the test unit cannot be integrated You now find yourself in the status overview cf section 4 1 Status overview page 19 3 2 Units Check the set protocol and the unit address directly at the test unit if you get no connection to your test unit Network parameters like IP address IP port subnet mask and default gateway must be set correctly during communication via network You usually get these data from your network administrator You find out how parameters must be entered at the test unit in your test unit s operation manual User Manual for CID Pro 4 02 17 Section 3 Program start up 18 CID PRO 4 02 User Manual Section4 Program parts and functions 4 Program parts and functions Status overview 4 1 seabessow 10119 pue BuiuJem obueyd sobessayy ot r Cu 2 00 au pasdeg Dun INS LOZ
143. rm chamber Temperature set value in the warm chamber left above e Temperature cold chamber Temperature set value in the cold chamber left below e Pre tempering warm chamber This temperature value is added to the warm difference chamber s set value The warm chamber heated to above right this temperature sum when the cradle is not located in this zone e Pre tempering cold chamber This temperature value is added to the cold difference chamber s set value The cold chamber is heated to below right this temperature sum when the cradle is not located in this zone e Time warm chamber Time the cradle spends in the warm chamber left lower center in minutes e Time cold chamber Time the cradle spends in the cold chamber left lower center in minutes e Cycles Number of warm chamber cold chamber cycles 4 11 1 2 Pretempering When the cradle moves into a chamber the ambient temperature in that chamber is altered The size of this alteration depends on the chamber temperature the cradle and the items to be tested as they enter into the chamber In order to return to the desired target value as quickly as possible after the cradle change the heating chamber is heated up to a certain value above the target value prior to the change Conversely the cooling chamber is cooled down to a certain value below the target value prior to the change These values are defined as pretempering The value is positive for the heating
144. rnnnrnnsennssnnn 147 4 11 1 5 Manual and program operaton 148 INN ICING EE 149 5 1 Serial interface RS 2372 150 5 2 Serial interface RS A9 151 5 3 Ne GO oy Pur 153 5 4 Network Version Remote PDC 154 5 5 PITT 154 6 Buttons of the CID Pro 4 02 SOftWare annxxrnnnnnnnnnnnnnnnnnnnnnnnnennnnnnennnnnnnnnnnnennnnnennnn 155 6 1 TEE 155 6 2 EI 156 6 3 Graphical measurement data analysis ccccccceecceeeceeeceeeeeeseeeeeeeseeseeeaeeeseees 157 6 4 FV CU WOO EE EE memo 158 6 5 WIS Wal Z 6 ER EE 158 1 e AN Upd l S asso ance csc ctr aa 159 7 1 Support section on the Intermet 159 7 2 SOWIE MI OM og EE RE EE 160 8 End user license agreement nnnnrnnunnnnnvnnnnunnnnnvnnnnunnnnvnnnnnnnnnnvrnnnnnnnnnvennnvevnnvnnnnnennnnere 161 8 1 GO OY OTA MEMO EE NE tenants 161 8 2 License agreement r ervnernvnnernanennrnvnnernenenenennnennunennennnnnernenennnennunnnunennennnnnennene 161 8 3 WAIT e REE 162 8 4 Place of fulfilment place of jurisdiction applicable Low 162 gt EE E E E E A 163 TO EMAIN 167 User Manual for CID Pro 4 02 5 Section 2 Installation and system requirements 2 Installation and system requirements 2 1 Licensing notes The GID PRO 4 02 can be tested free and without obligation You can evaluate measurement files and create test programs with the demo version communication over the serial interface is available exclusively in the full version If you have an Ethernet connection at the tes
145. rogram By confirming OK the following insert line is displayed after the marked line inert Prog 12 90 min There is a vertical light green control line in the graph this identifies the module program The third column 90 min are the total run time of the inserted program Section 4 Program parts and functions FA filename Inserted programs intemupt the main program The main program continues when the inserted program ends In inserted program analog and digital channel as well as timecontrol are active 32 insert program program n FA el 12 filename Drog ZU Inserted programs intemupt the main program The main program continues when the inserted program ends In inserted program analog and digital channel as well as timecontrol are active Take note Inserted module programs interrupt the main program The main program continues when the inserted module program ends In inserted module program analogue and digital channels as well as time control are active If a program is loaded with a name that is too long max length 16 characters including file extension an error message is displayed 218 CID Pro Error User Manual for CID PRO 4 02 The file name of the sub program is with gt 15 signs too long 11 Section4 Program parts and functions 4 4 4 12 Templates You have the option to create templates if you repeatedly access a certain program or test cy
146. rrence resolution and acknowledgement deletion of individual errors and warnings is listed chronologically here The function File gt Print as PDF file can be used to save the complete error history as a PDF file After you select the respective PDF function a dialogue is opened in which the name and the path of the saved PDF file can be indicated The storage path is the standard directory for report files The standard name is the addition Error history followed by the test unit number e g PDF file Error history Unit01 pdf Back closes the error history window again Take note If the No reply from this test unit message is displayed in this window this function is not yet implemented in your unit s controller software The colour of the error red and warnings orange display can be activated deactivated in the Options cf sec 4 9 3 9 Options event log page 135 130 CID PRO 4 02 User Manual 4 9 3 7 Power fail The power fail menu option shows a list of all power failures detected in the chosen test unit SE list of powerfails Shock Test Cabinet Test Unit 03 index ON OFF stat 7 08 VET 18553 07 VER 10 EE e nl FY EN VL yet IS rc BE LI DN Lz ie 12 09 3 10 16 23 44 02 08 10 10 34 16 0109 10 16 13 37 1 2 3 3 Section4 Program parts and functions di 0 10 16 27 21 08 0 10 03 oe 10 1 02 09 0 16 33 44 02 09 10 10 34 16 The list is displayed with a ma
147. rrrarrrrnnernnrnrnnrrnnennnnernernnnsennn 91 4 5 1 SE ie 91 4 5 2 DULOT EEE 92 4 5 3 Graphical measurement data analysis functions rrarrrnrrnnrrnarrranenanennnennnnr 93 4 5 3 1 Open and load measurement 93 4 5 3 2 Working with graphical measurement data analysis rrrrrrnnrrnrrnnnrnnnrnnnrn 95 4 5 3 3 Delete measurement 95 4 5 3 4 Print measurement arennnennnrnnnnnnnnnnnnnnnnnnnnnnnnnnennnrnnnennnennnennnennnennnennnennssnn 96 4 5 3 5 Print measurement as PDF reranonnnnnnnnnnnennnnnnrnnnrnnnrnnnrnnnennnrnnnrnnnnnnnnnnnennnen 96 4 5 3 6 Zoom functions graphical measurement data analysis 97 ED EON EE R 99 e e E ME EI SIS EEE EN NE 99 4 5 3 9 Options graphical measurement data analveis 100 4 5 3 10 Excel conversion program ss ssessersersrrrrrrrrrrrrrrsrrsrrsrrsrrnrrsrrsrrsrrsrrnnene 103 4 5 3 11 Display Measurement Values rrrnrnnnrrnnrnnnrnnnnnnnrnnernnrrnnnennnrnnernnnrnnsennee 106 452 NNN 106 45315 Merge measurement E 107 4 5 3 14 Cut current Measurement File Cursor rrrrrrnnnnnnnnnrnnnnnrnnnrennnnrnnnnrennnnen 107 10005 PE 108 4 5 3 16 Comments graphical measurement data analysis 110 4 6 Starting test programs outomatc 111 4 6 1 Selection the test cycle program 111 4 6 2 Recording the test cycle program 112 4 6 3 SE deele EEE EEE 114 4 6 4 Automate Mode ere 115 4 7 Manual measurement recording rrnnrrnrrvnnrvnnrrnnrrnnnnnnennnnnnnnnnnnnnnnnnennnenneen
148. s Convert to Excel Program Display Measure ment Value completely cursor position Copy to Clipboard Join Measurement Files Cut current Measurement File Cursor Setting 1 Setting 2 Setting 3 Setting 4 Setting 5 Setting 6 Setting 7 Setting 8 Setting 9 Setting 10 New Setting Delete Setting Help Also in toolbar gt lt X XxX X KK xX XD Xx KK XKX XD XK KR KR KR KK UK CK Key combi nation Ctrl O Ctrl D Ctrl P Ctrl F Ctrl E Ctrl R Ctrl U Ctrl Z Ctrl S Ctrl I Ctrl A Ctrl T Ctrl X Ctrl C Ctrl M F1 CID PRO 4 02 Reference Open and load measurement cf sec 4 5 3 1 p 93 Delete measurement cf sec 4 5 3 3 p 95 Print measurement cf sec 4 5 3 4 p 96 Print measurement as PDF cf sec 4 5 3 5 p 96 Open and load measurement 4 5 3 1 Exit the graphical measurement data analysis Zoom functions graphical measurement data analysis cf sec 4 5 3 6 p 97 Display cf sec 4 5 3 7 p 99 Analysis cf sec 4 5 3 8 p 99 Options graphical measurement data analysis cf sec 4 5 3 9 p 100 Excel conversion program cf sec 4 5 3 10 p 103 Display Measurement Values cf sec 4 5 3 11 p 106 Copy to clipboard cf sec 4 5 3 12 p 106 Merge measurement files cf sec 4 5 3 13 p 107 Cut current Measurement File Cursor cf sec 4 5 3 14 p 107 Settings cf sec 4 5 3 15 p 108 Comment graphical measurement data analysis cf
149. s above the Filename This path can be changed to a directory selection with the d button You can change default setting of this entered path in the configuration cf sec 4 2 5 Configuration Generally page 44 Click the button and you can select the desired file User Manual for CID PRO 4 02 93 Section4 Program parts and functions in your network Filename and measurement path are automatically set after Load acknowledgement and the measurement information is displayed Load your desired measurement file into the graph window The measurement is plotted on the graph after the measurement file has been completely read can vary widely depending on size and data volume Active record is displayed not greyed out when one measurement record is running which you can display directly The difference between loading and active record is that the active record is updated GA Searching for a measurement file The following window opens after clicking the search button File search e CID P RO 4 00 messung i F search in Text to search mess sub directory Filename C1D Messung_2010 09 02 11 459 54 m01 Back You have the following options here Path The search path is taken from the load window If you want to change a measurement file s search path click the button and select the desired path Confirm with Done Text to Search Enter the text you want to search for here All measurement files
150. s in the first column time you can copy these lines into the cut buffer This marked block is ultimately deleted gt cut cf sec 4 4 4 7 Copy insert a block of lines delete a block of lines page 72 7 Paste copied lines The Ctrl V combination or the B symbol inserts the copied line cf sec 5 and 6 Copy cut line after the currently active line and updates the list and graph Take note With the Ctr V key combination or the B symbol you can insert entire blocks besides a marked line If you have previously marked and copied or cut a block it is inserted after the currently active line and the list and graph are updated cf sec 4 4 4 7 Copy insert a block of lines delete a block of lines page 72 8 Wait function If you want to assign a wait function to a gt 2 Selection particular value proceed exactly as when changing a value line cf point 2 Change line Temper in C i New value 75 0 selected or by double clicking the left mouse With the Enter key if the desired field is button on the desired field Now you have the option of marking place point in the preceding field the Activate field in the Wait function area By setting the wait function you can now enter the tolerance within which the value is permitted to move so that the program can continue running This tolerance signifies the tolerance discrepancy between the nominal and actual value which must be under
151. s occur in the analysis deriving directly from the two cursors If these cursors are placed at characteristic positions in the measurement this position s features can be read off from the analysis The down and up values always relate to the left scale based on both cursors Depending on which cursor is above changing this cursor changes the up field It behaves the same way for the down field The left and right values relate to relative time based on the settings in the options Depending on which cursor is left changing this cursor changes the left field It behaves the same way for the right field The left field C min represents the indicated curve s calculated gradient and consequently that of the two cursor crosshairs The difference and duration values of the area enclosed by the crosshair cursors serve to realise the measurement record and show the difference between the two axes here C and min Analysts up down difference T min 5493 40 03 24 50 KL 0 14 left right duration 2705 73 2865 14 9179 41 min Activating the Analysis Check mark View Evaluation in the menu key combination Ctrl A or select Extra gt Options gt Display gt Show Evaluation User Manual for CID Pro 4 02 99 Section4 Program parts and functions 4 5 3 9 Options graphical measurement data analysis Preface Various options can be set and changed in the following poi
152. se compare sec 4 6 Starting test programs automatic page 111 concerning the exact procedure for the automatic operation of a data pool program Take note It hardly pays to use this data pool program technique if you have many different test units This also applies to a few units with little in common because it really must involve identical configurations If you have several identical test units Le units with identical configurations then the data pool function makes sense because you save time not having to repeatedly write a new but identical test program for a different unit Besides the probability of error decreases when you only have to maintain one program in contrast to five ten or more identical programs 4 4 4 16 Save file as library Libraries differ from templates cf sec 4 4 4 12 Templates page 78 in the following respects Display libraries are displayed for all test units Storage libraries can only be stored in the sample directory CID installation pathizyklus sample 1 Create a test cycle program 2 Save the library with the Extras Save file as library The path and the file extension are not changeable here Path CID installation pathizyklusisample You can change or adjust this path in the configuration general paths register Extension clib CTS Library e g CACID PRO 4 00 zyklus sample lIEC_68 2 30 Modul clib 86 CID PRO 4 02 User Manual Section4 Program parts and functions 3
153. se or an error If it is rotating and green then the program is running 26 CID PRO 4 02 User Manual Section4 Program parts and functions 4 1 7 Trend graph In the screen s top centre area a symbol bar offers selection options between different displays Not all of these buttons are visible under some circumstances This depends on the unit s type and operational state If the trend graphic button is activated the status overview window will show the trend graph This graph shows the temperature profile and the humidity profile when present with set and actual values respectively Temper Humidity 3 09 00 22 09 30 22 10 00 22 10 30 22 11 00 22 06 08 2010 06 08 2010 06 08 2010 06 08 2010 06 08 2010 The trend graph always shows a constant time window up to the current instant The special configuration of this time windows is illustrated in more detail in sec 4 2 2 Configuration Communication page 36 This scale applies for both channels temperature and humidity as needed The channels colours are assigned as follows Temperature actual value light red Temperature set value dark red Humidity actual value light blue Humidity set value dark blue Take note Trend graph data are only stored temporarily You cannot replace a measurement record User Manual for CID Pro 4 02 27 Section4 Program parts and functions If the automatic button is activated or a test cycle program is running in
154. shot before this line counts as completed That means that a tolerance threshold of 0 0 stops the program at this place since this difference cannot be undershot For the most part a tolerance of 1K for the temperature channel and 3 5 rH for the humidity makes sense 62 CID PRO 4 02 User Manual Section4 Program parts and functions The value is accepted after confirmation with OK With an activated wait function the list entry format changes from thin black 10 eoj 750 a H NM 10 so 7350 a H NJ The wait function causes the controller to wait long enough after completion of the line for the actual value to reach the analogue channel s tolerance Only then is the next line executed to heavy blue Take note Only one channel per line can be assigned a wait function 9 Software limit It is possible to set a software limit for each Selection analogue channel A software limit means that the unit reports an error and shuts down as soon as the channel s New value actual value lies outside of the permitted range These limits are transmitted to the controller when the test program is started The limits are valid while the program is running If the program terminates the limits valid before the program started become valid again cf sec 4 2 4 Temper in C Configuration Test specimen protection page Wait function 43 A channel s limits can be entered in any arbitrary l tolerance line Minimum
155. switch will only be displayed if the Enable locking terminal option is set in the configuration cf sec 4 2 5 Configuration Generally Options Enable locking terminal page 44 A power outage or toggling the unit s main ON OFF switch unlocks the keyboard If the connected test unit s software version does not allow keyboard locking this unit s key icon is not visible 32 CID PRO 4 02 User Manual Section4 Program parts and functions 4 1 12 Error list The Unit and error status cf sec 4 1 5 page 23 displays the existing error warning From this view it is not clear if other errors warnings exist The error list will display all existing errors and warnings of the test unit currently selected Error list Shock Test Cabinet Test Unit 03 unit index erortedt Index 3 Sensor F condenser 03 641 nstall compressed air 10 B63 Characteristics of the error list e The error list will only be displayed where an error a warning exists If the test unit operates with no errors warnings the error list is masked e By default the error list is displayed in the event of an error a warning If it should not be generally displayed the Show error list option must be deactivated in the configuration cf sec 4 2 5 Configuration Generally Options Show error list page 44 e The error list will be updated regularly e Unlike the error list from the Event logs reports these entries cannot be a
156. t for personal or material damage on privately used articles is covered by the German Product Liability Act Further claims are excluded 8 4 Place of fulfilment place of jurisdiction applicable law Place of fulfilment for all claims resulting from business relationships is 72379 Hechingen Germany Place of jurisdiction for all claims resulting from business relationships including those from exchange and cheques is the court in whose district our head office is located We are however also entitled to claim against customers at their general place of jurisdiction The laws of the Federal Republic of Germany are exclusively applicable to all legal relation ships between us and our customers Application of the UN Purchasing Rights CISG and those of international private law is excluded If one individual regulation is or becomes ineffective the effectiveness of all other regulations or agreements will not be affected A suitable regulation will then apply instead of the ineffective regulation which most closely approaches the ineffective clause in the context of legally permissible possibilities 162 CID PRO 4 02 User Manual Index Authorizations ranernnvvnnvvnnvnnnvvnnvnnuennuenn 7 Buttons Overview elt te 156 Event 00S tee Aere bt Eet 158 Graphical measuremenmt 157 Status OVerVieWw rrnranrrrnnrerrnnrrnnnre 155 Visualization rrrrnrrnrnarrnrrnannnerner 158 Configuration anxannnnnnnnnnennnnennnnu
157. t overview display cp sec 4 1 3 Test Units page 21 to yellow or red manual started active recording with immediate start with delayed start Test Units Test Units Lal Temperature Cabinet 1 r Temperature Cabinet 1 Sa Shock Test Cabinet WW Shock Test Cabinet Temperature Cabinet 2 l Temperature Cabinet 2 p planned Test Unit p planned Test Unit Take note This started manual recording runs until the hand stops again cf sec 4 7 2 Stopping a manual measurement recording page 122 It is to be used mainly during manual operation or when automatic recording is not possible 4 7 2 Stopping a manual measurement recording In contract to automatic recording manual recording does not stop independently Click the D icon if you want to stop manual recording of the selected test unit Take note The Stop icon can also stop automatic recording 122 CID PRO 4 02 User Manual Section4 Program parts and functions 4 8 Operating hours and event counter The counter menu presents two different lists LS Counter of Climate Cabinet Test Unit 01 Runtime tual mit Limit Hour coun Compresso 2 0 00 9 Compr Pr 25 2 0 00 pump circ 24 50 0 00 Drain wat 5 3 00 00 Unit imit Comment sv bypass sv reinje sy pre co ev clim sv suctio sv bypass sv dehum The top list shows the operating hour s counter here the total operating hours in unit 1 and further operating hours from the
158. t unit licensing would be carried out over this connection and communication would occur via the CID PR0o network version CID PRO 4 02 is licensed per computer or per test unit That means you need a hardware key dongle to communicate via serial interface or an Ethernet connection to the test unit to communicate via Ethernet interface 2 2 System requirements PC with 1 GHz Pentium processor or higher Microsoft Windows 7 8 32 and 64 bit Windows Vista XP or Windows 2000 Service Pack 3 or higher VGA 256 colours 1280 x 1024 pixels or higher Min 256 MB RAM 512 MB recommended Memory is dependent on the operating system 200 MB free disk space 1 GB recommended Microsoft compatible mouse CDROM drive Free serial interface or Ethernet interface Free USB port for a hardware key dongle 2 3 Authorizations You must be a member of the local administrators group or have the authorization to install CID PRO 4 02 If you are a domain administrator then you generally have the appropriate privileges For modifications and updates of the various files programs measurement records or report files you must have read and write access to the GID PRoO installation folder while operating the software User Manual for CID Pro 4 02 7 Section 2 Installation and system requirements 2 4 Installation Its very easy to install the CID PRO 4 0 2 Software Please proceed as follows 1 2 3 gt Start
159. tem e Software changes like GID PRO start e Configuration changes like changed number of units All changes of the unit e Changes to the unit s operation like e g manually starting the unit e Changes to digital or analogue channels like e g changed temperature e Connection messages like e g no connection to test unit 5 All errors of the unit red entry All warnings of the unit orange entry ne 0830 Ca 08 32 19 03 Waming nstall compressed air 10 863 E 06 08 2010 08 32 19 01 Eror Eror Fo at switch waterbath v 580 F 06 08 2010 08 32 16 H No connection to test unit 06 08 2010 08 32 13 CID user accounts not active 06 08 2010 08 32 04 01 CID Start Cycle No 1 C CID PRO 4 00 zyklus C 70 350 201 still running Elapsed time 00 24 hh mm E The columns have the following meaning Date Date on which the message was created Time Time at which the message was created Unit Unit number information if a unit specific message is involved empty Information whether warning or error Action Message Index Number of messages in the list User Manual for CID Pro 4 02 29 Section4 Program parts and functions 4 1 9 Digital channels The display of the digital channel relates to the currently displayed test unit Softkeys and marker channels are displayed dynamically depending on unit configuration like how many channels this unit possesses Only the digital channels actually present
160. the current unit the automatic display will be activated The automatic display gives you detailed information about the current test program This is displayed graphically see next figure as well as in program automatic screen form cf sec 4 1 6 Program automatic page 26 ou 250 500 750 1000 1250 1500 1750 2000 2250 2500 2750 3000 3250 3500 3750 4000 4250 4500 4910 Temper in C Humidity in rH The yellow bar shows the current position in the test program It moves through the program following the temperature index value If there are loops in the program they are symbolised as white vertical lines Reaching the end of a loop the yellow bar jumps back to the beginning scaling of the Y axis Y min and Y max is determined by the smallest and largest Y values of all the analogue channels depicted Y min and Y max are rounded down resp up and adapted with 10 The push buttons for temper and if necessary humidity or up to three other analogue channels change the scaling to the range of the selected channel 28 CID PRO 4 02 User Manual Section4 Program parts and functions 4 1 8 Messages change warning and error messages This short six line excerpt from the Event logs reports give you a short overview of the latest messages which are shown independent from the unit Furthermore the red errors display and the orange warnings display are often very helpful The messages are All changes of the sys
161. the context of this agreement 8 2 License agreement The following licence conditions apply to a software product and their usage rights as a supplement to our general terms and conditions which can be downloaded from our home page The licence conditions are acknowledged by the orderer on acceptance of the delivery or service at the latest when the software is installed CTS GmbH allows the orderer of the computer program and the associated documentation and subsequent amendments hereinafter referred to as software non exclusive and non transferable usage rights for internal use Copyright ownership and all other rights to the software including its copies remain with the manufacturer The customer has no rights to receive the source code program It is possible that the software is protected by copy protection Any bypassing of copy protection contained in the software is considered to be illegal Any reproduction of software irrespective of which type or on which carrier is illegal with the exception of backup copies explicitly labelled as such This also applies to internal use unless the reproduction is used for decompiling under the strict preconditions of the German 69e UrhG laws The orderer must ensure that the software is not accessible without previous written authorisation from CTS GmbH User Manual for CID Pro 4 02 161 Section 8 End user license agreement 8 3 Warranty The contractual parties agree that it is
162. the report file taking into account the restrictions of the submenu Extras gt Options cf sec 4 9 3 9 Options event log page 135 All comments and messages which are not filtered out are exported The selected function then exports the report entries as a text file After you select the respective function a dialogue is opened where you can indicate the name and the path of the saved text file The storage path is the standard directory for report files The standard name is the addition Report followed by the name of the loaded report file e g Report file 20130401 REP Text file Report 20130401 txt If the filtered report file is to be created as a TXT file the addition filtered is added e g Report file 20130401 REP Text file Report 20130401 filtered txt 128 CID PRO 4 02 User Manual Section4 Program parts and functions 4 9 3 6 Error list The Error list menu option shows a list of all errors currently at issue in the chosen test unit Sak Error list Shock Test Cabinet Test Unit 03 list of actuell error unit index emortext High pressure pre cool 03 650 High pressure cooling 03 640 Them Protect Fan hot space 0 Them Protect Fan cold space motor protect lit 22421 motor protect compr PC 03402 026 motor protect compr C 03441 045 nstall compressed air 10 663 3 3 3 3 A 3 3 3 You can select individual errors to quit error them This means that if the error is no longer an issue in th
163. tion files path is mml needed to exchange nel Hez configuration files over the CACID PRO DO isual m network GID PRO 4 02 client server operation Options Otherwise the configuration CT Ignore unused test units files can always be found in the Enable locking terminal software s installation directory TT Prog exp function Language of unit text ICT separat logfile English For measurement data it can Show error list make special sense to convert Sender Address of E Mail Message this path to a network path so CID Message cts umweltsimulation de that backup can occur Path and Name of Logfile CACID PRO 4 00Milescan cid_en bted The adjoining button opens a epes selection window to change the Nindow Size path A new path is written into e oe ee on the field after confirmation settings Fullscreen window Options Function Significance If this option is set units that fail to answer a query three times running will no longer be queried Querying only restarts after selection of the corresponding unit in the status overview or after restarting the GID PRO 4 02 Ignore unused software test units It can make sense to set this option if you have not consecutively numbered your units starting with 1 because timeouts impacting the reaction time can occur while querying non present units 44 CID PRO 4 02 User Manual Enable locking terminal Prog exp function Separate log file Show error list Send
164. true manual operation you must deactivate the automatic digital channel visible only in the CID PRo 4 02 software but not on the unit s hand set This automatic channel has the following significance automatic 1 Start the software from the default shock test program automatic 0 Start the software manually Here the cradle can only be moved manually 148 CID PRO 4 02 User Manual Section 5 Networking 5 Networking The following are possibilities when networking the test units LAN network TCPAP protocol RS 485 z RS232 R CID Pro CID Pro full version network version me Gateway RS 232 RS 485 laa aa JAFFER Several units are connected to a full GID PRO 4 02 version with a local printer User Manual for CID Pro 4 02 149 Section 5 Networking 5 1 Serial interface RS 232 Test Unit Connect the unit to the user PC with a serial RS232 interface cable The cable must be a crossover e Set the unit address if required in the unit configuration on the seven segment operating panel using the key sequence E P P or using the touch screen operating panel you can set the unit address and the parameters for the serial interface under Mainmenue 2 3 gt Settings gt Interfaces These must conform with e You should set the same parameters for the serial interface in the configuration of the CID PRO 4 02 software cf sec 4 2 2 Communication Serial interface page 37 In addition to this note
165. ts The files to be converted can be marked in the list Multiple selections are possible The directory can be changed and a file directly selected with the button The new path is then taken and the list updated based on the path In the program s right area stand the data describing in more detail the measurement active at the moment selected in the Filename field and marked in the list Start end time Number of lines i e measurement values Number of analogue digital channels Measurement data comments Listing of all analogue and digital channels User Manual for CID Pro 4 02 103 Section4 Program parts and functions The analogue and digital lists provide all the channels which can be represented with the measurement file All channels are checked by default In other words all channels are processed during the conversion If however only particular channels are needed because some channels are unimportant or there is just too much data the important channels stay checked and the unneeded channels are deactivated unchecked Now only the channels activated and selected with check marks are converted The decimal places relate to the output from the analogue channels The Comments are purely for display and cannot be changed It certainly won t be included in the conversion Back terminates the program Convert starts the program Now all marked files are individually converted one after another CI1D Messung
166. u option if you want to print out the graph and values list together The functions are the respective individual functions executed one after the other which can be individually configured in the settings cf point 1 Printer page setup graph list 5 Print screen a The screen will be output for you as you see it on the monitor This function prints a screenshot except for the tool and menu bars 4 4 4 6 Print as PDF The PDF print functions create PDF files with the same content as the standard print functions cf sec 4 4 4 5 Printer page setup and print Point 2 Print graph Point 3 Print list and Point 5 Print screen After you select these functions a dialogue is opened in which you can indicate the name and path under which the PDF file is to be saved The path is the standard directory for the test programs The name differs as follows Print graph W The standard name is the test program opened followed by the unit number and the appendix Graphic e g Test program NewProgram z01 PDF graph file NewProgram z01 Graphic pdf Print list The standard name is the test program opened followed by the unit number and the appendix List eg Test program NewProgram z01 PDF list file NewProgram_z01_List pdf Print screen E The standard name is the test program opened followed by the unit number and the appendix Screen e g Test program NewProgram z01 PDF screen file NewProgram_z01_Screen
167. unit The method of dragging the desired area with the mouse was explained in this instruction manual based on the upper left to lower right corner You can carry out this function in an arbitrary direction The zoom area is depicted during zooming by a dashed rectangle This enables the area to be defined better 98 CID PRO 4 02 User Manual Section4 Program parts and functions 4 5 3 7 Display The currently displayed curves in the associated colours can Diels be seen in the small display legend on the graphic screen If you double click on of the analogue channels the scaling Temper st 00C 3007 changes depending on option setting cf Sec 4 5 3 9 Options Feuchte Set Jr page 100 left right on the graph The object as well as the Er al area It denotes change to the preset colour Wasservor Act O 30 The values in brackets e g 100 C 200 C display the Tempul Set 3500 2100 current ranges of the scales This is a very useful function ome oc iti when zooming a Min max values are the minimum and maximum values of the sanke wo tmi individual channels of the current measurement These are only 7 5 displayed when the Min Max checkbox is activated in the option w Display cf Sec 4 5 3 9 Options page 100 Activating the Display Check mark View Display in the menu key combination Ctrl l or select Extra gt Options gt Display gt Show Small Display 4 5 3 8 Analysis Value
168. uses a comma as the decimal symbol e g 123 40 C Microsoft Excel may choose the decimal delimiter based on country Menu Extras gt Options gt International gt delimiter resp File gt Options gt Advanced gt Editing options gt delimiter The delimiter must match here to import files to be converted without problem Individual table cells are separated with semicolons System dependent value distortions could arise if the tables are compared with a different system If you activate Interpolation to fixed time period all measured values are adapted to the time pattern entered and required by you in this case 60 seconds 1 minute Interpolation to fed time period time period 60 sec wY z B C min oe 8 a n 08 08 00 08 01 00 08 02 00 08 03 00 08 04 00 08 05 00 08 06 00 Zeit min 08 01 20 Legend ssnee Original curve Original points form the measurement file that are easily time shifted Interpolated approximated curves from the measurement file with time shifted points Calculated values which now correspond to full minutes Caution Take note User Manual Curve through calculated values which now correspond to full minutes The measured values are adapted in other words they are calculated and not measured The measurement value y axis e g C is calculated proportionally from the preceding and following point For minor changes in the curve the measured and
169. utes or hours Max value 120 If you have set the convert program lines option active and you change the unit relative Unit to your previous setting the editor tries to E Seconds convert the old time values into the new unit Minutes from minutes to hours for example when A H Fl convert i ours Conve whole hours every 60 minutes were entered program lines on the line in question If conversion is possible you can perform it after the confirmation prompt Conversion from hours to minutes is always possible If the convert program lines option is not set active only the units are changed That means that 5 minutes just become 5 hours Possible conversions convert program lines Conversions yes no Seconds to hours conversion check Gi Seconds to minutes conversion check Q Minutes to hours conversion check Q Minutes to seconds Q Gi Hours to minutes Q Q Hours to seconds Gv Gv No line with values under five seconds should be used for the seconds time basis Correct synchronization is not guaranteed otherwise due to the controller s cycle time 80 CID PRO 4 02 User Manual Section4 Program parts and functions Cursor Net t The granularity with which the cursor jumps for graphical input can be defined in the grid This makes it easier to hit the desired points A value f Y value ell Programs in unit The potential exists here to save programs already in the controller onto the co
170. ximum of ten entries with the periods within which the test unit was switched on or off For the controller the ON OFF switching of the unit s main switch is considered as a power failure Back closes the power failure list window again Take note User Manual If the No reply from this test unit message is displayed in this window this function is not yet implemented in your unit s controller software for CID PRO 4 02 131 Section4 Program parts and functions 4 9 3 8 E Mail message The E Mail message menu option enables setting and activation of the e mail messages which CID PRO 4 02 software sends automatically You need internet or local network access and an SMTP server that supports message dispatch to be able to use this function The potential to send e mail depends heavily on the available network The E Mail message menu option opens a send list window using the existing send configuration here CID4 E Mail Test 3 sendlist available configurations Deactivate Change All stored send configurations are shown e Black entries are not activated e Green entries are activated and send e mails for the appropriate events 132 CID PRO 4 02 User Manual Section4 Program parts and functions New send configuration 2 sendoptions You use New to save a new send configuration The necessary information is entered in this window and the events Receiveraddress established for which an e mail w