Home

WZB-05ET User's Manual (ZigBee HA Profile) Ver. 1.03

image

Contents

1. Ni 1 2 3 4 5 6 7 8 9 LigBee 2 WZB 05ET User s Manual Control your world WZB 05ET User s Manual ZigBee HA Profile Ver 1 03 Copyright 2011 14 Nietzsche Enterprise Co Ltd All rights reserved Nietzsche Enterprise reserves the right to make changes and improvements to its products without notice Contact Information Email service nhr com tw Website www nhr com tw Content Package Content and WZB O5ET VIEWS esssssssseesesseseerssssereresesreresesesreresesresreresesesreeese 2 Installing Mounting for WZB O5ET ice eccsesscecesessseeceecessseceeceecesseeeeeceseseaeecescessaeaeeeees 3 POWER OM NV ZOE M penison e E T E 4 Configuring IP Address and Host PC Port for WZB O5ET cccccccccsesssseceecsssereeeeeeeens 4 Enabling WZB O5ET to Permit Join Other Devices to its Network ou eee 6 Removing WZB OS5ET from the Parent s Network cccssssssecescsssceceecessseatecaeecescseees 7 WW ZB AOS EN VE Stats a E 7 FACE CC CSE en E E EE ITE ONEN 7 Product Specifications sasona an E EAT ane 8 NR WZB O5ET User s Manual Congratulations for choosing a world class digital temperature and humidity sensor using ZigBee wireless transmission technology This manual is designed to help set up and get the most from the sensor in a few short minutes Safety notice Please read and follow the instructions before using this product e To prevent electrical shock or fire do not disasse
2. c 77 00 91 IP Address Selection Subnet Mask 255 ETIE ll rime 192 General Configuration Settings UGGINCEOPUICR NHR W2ZB OSET Tile Mim 6432 Restore Factory Defaults WZB O5ET has been successfully configured NHR ZigBee2Ethernet Module Restore all options to their factory default states Copyright 2077 Nietzsche Enterprise Co LTD NR WZB OS5ET User s Manual 5 Enabling WZB 05ET to Permit Join Other Devices to its Network Requirements e Child device such as router eg STH MO2ZB WZB 01USBR WZB 02485R or end device eg STH 01 series STH MO2ZB STH 03ZB SO5 series e Sharp pointed tool b Ensure child device s to be joined to WZB O5ET s network is in ready to join status see relevant device s manual c Use a sharp pointed tool to apply 1 quick press to the link switch on WZB O5ET the blue LED will flash twice every 3 seconds for up to 60 seconds to permit join other devices to its network d If a child device has successfully joined WZB O5ET s network the blue LED will flash 3 times to confirm successful addition then return to a flash per second pattern e Check the status of the device to confirm it has been connected see relevant device s manual f Repeat the above steps until all devices have been added successfully E NHR ZigBee Simple Data View V1 28 13 joj x History Received Packet Settings View Clase End Device Router Status HOw 11 13 10 Chr Ne oveeNa
3. ert wall plugs into the 2 holes then use size 1 Phillips screwdriver to fasten the screws securing the mounting cradle Note pay careful attention to the orientation of the mounting cradle d Install and remove WZB O5ET using the following 2 step action to ensure the mounting cradle has been correctly and securely installed and WZB O5ET can be installed and removed S wy a N y MR Made in Taiwan NA in Taiwa Taiwan Made in For installation using the built in hanging fixture b If necessary pre drill mounting hole with the appropriate drill bit 5mm approx 0 2 inches if using wall plugs or 3 5mm approx 0 14 inches if not using wall plugs c If necessary first insert the wall plug then use size 1 Phillips screwdriver to fasten the screw leaving 2mm 0 08 inches protruding for seating STH M02ZB s built in hanging fixture d Hang and remove WZB O5ET on the protruding screw to ensure it can be installed and removed Initial hardware installation for WZB O5ET has been successfully completed NR WZB OS5ET User s Manual 3 Powering On WZB O5ET Requirements e DC5V USB adapter and cable a Connect USB cable s Standard A plug to DC 5V USB adapter and plug into live AC Mains socket b Connect USB cable s Micro B plug to WZB O5ET c The status LED on WZB O5ET should start flashing WZB OSET has been successfully powered on Recommendation It is strongly recommended to power on WZB O5ET just before j
4. etwork 9 Product Specifications Chip Set Wireless Protocol Operating Frequency Channel Transmission Range Transmission Data Rate RF Output Power Power Supply Receiver Sensitivity Operating Environment Power Consumption ESD Protection Antenna Network Topology Enabling Devices Dimensions Weight Supported Systems Certifications T1 ZigBee SoC cc2530F256 256K Flash Compliant IEEE 802 15 4 ZigBee2007 PRO HA Profile 2 4GHz ISM band 16CH 500m 1640 4ft line of sight 250kbps Max 18dBm DC 5V USB Adapter 92dBm 10 80 C 90 relative humidity 0 8W 4KV contact 2dBi Omni SMA Antenna Star Tree Mesh End Device NHR HA Devices Router S05 R WZB 01USBR WZB 02485R 197 L x 43 W x 21 H mm 141 8 50z Includes Cable Windows NT Win 8 CE FCC
5. make the changes as shown below Outstanding in the field Port 1 Settings CULE NHR WZB OS5ET om 8811 EE 192 168 1200 WEEE 00 01 3c 77 00 91 Settings The current settings for port 1 may be changed using the form below To make the new settings apply each time the S2E module is reset ensure that Make these the default settings is checked before pressing the Apply Changes button If this control is not checked the changes are applied to the port but the existing defaults are used whenever the module is next reset NHR ZigBee2Ethernet Module o SECONGS lt 256 0 for no timeout C i gt Make these the default settings X Copyright 2011 Nietzsche Enterprise Co LTD g Click on Miscellaneous Setting on the left side of the screen gt Update the IP Address Selection details with the reserve IP address and other network configuration obtained from the steps above if on a local network or choose ones that will not cause conflict Default settings IP Address 192 168 1 200 Subnet Mask 255 255 255 0 Default Gateway 192 168 1 254 If WZB OO5ET will not be networked click Update Setting to make the changes as shown below Home Porto Sertings Port 1 Settmgs Miscellaneous Settings Firmware Update Outstanding in the field Replace WZB O5ET into mounting cradle as rewquired Miscellaneous Settings hols NHR WZB 05ET Firmware Revision 8811 192 168 1 200 00 01 3
6. mble or expose the unit to liquids of any kind e Only use attachments and or accessories specified by the manufacturer 1 Package Content and WZB OSET Views NHR WZB OSET Ethernet Receiver Mounting fixtures mounting DC 5V USB Adapter and Micro B with Antenna cradle 2 wall plugs 2 screws to Standard A USB Cable i pam FT If any of the above is missing please contact your supplier Front Bottom Antenna O Oo Status LED NS NA Link Button Made in Taiwan USB Micro B Socket Ethernet Port Side Back aos Product Serial Number amp lt 5 Unique MAC Address NR WZB O5ET User s Manual 2 Installing Mounting for WZB O5ET Requirements e Mounting fixtures e Drill with 5mm 0 2 inches drill bit size if using wall plugs or 3 5mm 0 14 inches drill bit size if not using wall plugs e Size 1 Phillips screwdriver a Locate WZB O5ET within 1 0m of AC mains socket and with at least 15cm approx 6 inches Spacing on each side except on mounting side avoiding the following sources of interference direct sunlight air flow from vents fans doors windows heaters sources of steam oil vapor etc For installation using the mounting cradle b If necessary pre drill mounting holes use mounting cradle for alignment with the appropriate drill bit 5mm approx 0 2 inches if using wall plugs or 3 5mm approx 0 14 inches if not using wall plugs c If necessary first ins
7. n 7 WZB O5ET LED Statuses The table below shows the LED status for WZB OS5ET Blue LED Sequence Status flash every second Ready Ready to receive data from slave devices 2 blue flashes in 3 second interval Connecting Searching for devices to connect 3 blue flashes Connected Found and connected to device gt Return to Ready Rapid repeated flashes up to 30 Removing Removing device gt Return to Ready seconds Blue amp Red on for 3 seconds Reset Resetting linkage to all ZigBee devices 8 ZigBee Reset a To disconnect and reset all the connected devices from WZB O5ET press link switch for 3 seconds Ni b LED light should show Reset status Blue amp Red light for 3 seconds gt Blue LED light should return to Ready status 1 blue flash repeated in 1 second interval c All connected devices stored in WZB O5ET have been disconnected WZB O5ET User s Manual Note Devices that were stored in WZB O5ET before the reset process are now orphaned and need to reset individually to connect to the same or different data receivers Recommendation Before removing power from WZB O5ET removing it from the network or resetting please ensure its router capability is no longer needed on the network by child device s Once WZB O5ET has been removed from the network or reset it is suggested to remove power from the WZB O5ET when not in use to reduce power wastage RF traffic and unintentional joining to original or new n
8. ne hidden olf fesate BonPos nine Tne oro Bat fox La A Sensor Yo 0012460002F63C25 5824 21 500 B42 14 32 2014 03 07 11 12 45 2 6 _ 03 06 17 04 Try reconnect timeogt A Server IP 192 168 1 200 Disconnect DDE 1754 Server Connect Successll Read Channel i15 Read FAN ID 1028 Read MAC c on 24600021 44693 NR WZB O5ET User s Manual Recommendation Open the DavaView before joining sensors to WZB O5ET to confirm with joined Sensors 6 Removing Devices from WZB OS5ET Requirements e Child device such as router eg STH M02ZB WZB 01USBR WZB 02485R or end device eg STH 01 series STH MO2ZB STH 03ZB SO5 series e Sharp pointed tool a Ensure WZB O5ET is powered on See Product Installation Power On b Ensure the devices is powered on See relevant devices manual and is connected it WZB O5ET or one of its slave routers c Use pin or other appropriate tool to apply 2 quick presses to link switch on WZB O5ET gt the blue light should flash rapidly for up to 30 seconds or until removal has been successful Uninstallation should take place within 30 seconds d Use the pin to apply 3 quick presses to the link switch on the device to be removed gt The red LED light should flash rapidly for up to 30 seconds or until removal is successful f Check the status of the device to confirm it has been removed See relevant device s manual g WZB O5ET should return to a flash per second patter
9. oining to parent device or when required as this will reduce power wastage and RF traffic 4 Configuring IP Address and Host PC Port for WZB O5ET Requirements e Ethernet Cable a Powering on WZB O5ET See Powering On WZB O5ET b If necessary remove WZB O5ET from the mounting cradle c If WZB O5ET will be added to a network reserve an IP address and port on that network for WZB OSET check with local network administrator to obtain configuration details d Use the Ethernet cable to connect WZB O5ET to a host machine e Use a web browser on the host machine to access WZB O5ET internet web server the factory Default IP Address is 192 168 1 200 gt It will bring up the configuration screen as shown below NA NHR ZigBee2Ethernet Module Status amp Configuration Home Name e zose ma oo Settings Current port settings Miscellaneous a E L Firmware 9600 bits secon d 9600 bits second Update 8 bits character 8 bits character None None 1 dit s 1 ditis None None 23 10010 N A N A Server Server Teinet Raw N A N A baad Rate eT 0 seconds 0 seconds f Click on Port 1 Settings on the left side of the screen gt update the Local Telnet Port Number with the reserve port obtained from steps above if on a local network or choose one 4 Ni WZB OS5ET User s Manual that will not cause conflict eg 10010 if WZB O5ET will not be networked gt click Submit to