Home

GOD180 User Manual

image

Contents

1. STEAMA GOD180 User Manual 1 To Our Customers Thank you very much for choosing our GOD180 Before using please read this user s manual carefully In order to check it later please keep the manual properly after reading If there s any questions please feel free to contact our After Sales Department 2 Diagrammatic Sketch _ s eo a TYY eerus gt gt Screen Power Button QU eae NY tg yi button W g 3 God180 standard configurations 1 x God180 Body 1 x Cross screwdriver 1 x English user manual 1 x Certification 1 x Canvas Bag 4 Basic parameter God180 colors Black Blue Red Croci Silver God180 size 119 X 69 X 30 mm God180 input voltage DC 9 6V 12 6V God180 output voltage DC 1 5V 10 5V God180 output power 5W 180W GOD180 hardware protection functions Protection of short circuit When the current exceeds 30A it would stop to work Protection of opposite connection When the positive and negative poles of batteries are opposite no working Protection of temperature control It could monitor the IC s nearby temperature changing when vaping if the temperature exceeds 80C it would stop to work Protection of low voltage When the battery capacity is lower than 9 6V it would turn off automatically GOD180 software protection functions Two patterns can be supported one is the normal mode and the other is super mode The normal mod only support 5 80W If you want to tur
2. in the tube following the as 6 2B 6 2 a 6 2 B 6 4 Connect the atomizer to the 510 thread clockwise 6 5 Click the power button 5 times in 2 seconds open GOD180 and it would show boot screen 6 6 Click the power button 3 times in 2 seconds enter the main menu mod to set the working parameter Refer to the display content and function specification 6 7 Exit the main menu display the standby screen and then adjust to get the power you want 6 8 Press the power button to vape Attentions 1 GOD180 is the super power product please make sure the heating coil you used could be stand the power value before using in case of damaging the heating coil 2 GOD180 needs to be matched with 18650 battery 80W 180W battery s continuous discharge current must be greater than 25A to insure to output enough power as well as reduce the battery s heating in the process of working 3 Non enthusiastic fan would be suggested to choose power form low to high first time and keep eyes on the state of atomizer to avoid burning yourself by improper handling
3. ing Reset Puff Press button to Reset Puff menu option press the Enter button clean away the smoking puffs and time Exit Press the button to Exit menu option press the Enter button to exit secondary menu Power Setting Select Power Setting option in main menu press the Enter button to enter the secondary menu Fehler Verweisquelle konnte nicht gefunden werden Normal Mode Super Mode secondary menu Warning Continous Discharge Current for battery must be over 25A Three level menu Normal Mode Normal mode default option power range 5 80W Super Mode Super mode power range from 5w to 180W with strict requirements on battery performance suitable for enthusiasts the screen will show the warning message after selecting this option Device Select Device option in main menu press the Enter button to enter the secondary menu Fehler Verweisquelle konnte nicht gefunden werden Series No SXXXXXX Version 1 0 a Software version number a Product ID number a Copyright and trademark information Exit Select the Exit option in main menu press the Enter button to exit the menu mode Puff Info Copyright 2014 Shenzhen Simeiyue Technology Co Ltd Power Setting Device Exit 6 How to use 6 1 Using cross screwdriver back out the GOD180 top cover s screw from counterclockwise and open the top cover 6 2 Install 3 pieces of 18650 batteries
4. n to the 81 180W please make sure that the battery continuously discharge current could be exceeded 25A if it does then could open the super mod Protection of overtime If the time of a cigarette was longer than the set time it would stop working 5 Display content amp Function description sy LIVE LONG AND VAPE ON Boot Animation Atomizer Detecting 1 542 Initial Testing Resistance we ey Normal Standby Screen Low Power Low Power Display Atomizer Short Display of Atomizer Short circuit No Atomizer Detected No Atomizer Display Over 8s Protection Overtime Protection Display Power Off Power Off Display 13W 2 99 Normal Smoke Display under Manual Mode Auto 15W Normal Smoke Display under automatic mode Overtime Protection Setting Choose Overtime Protection on Primary Menu Overtime Protection Power Off Screen Setting Vapor Setting Press power button to enter the secondary menu 5 30W 10S 30 80W TS 80 180W 55 Exit Use to choose the wattage rang then press power button to select time setting on next sub menu Adjust time from 1s to 10s by button then press power button back to previous menu Next choose option exit and press power button to return to the primary menu 5 30W _10S_ 30 80W 1S 80 180W 5S Exit Power Off Choose Power Off on Primary Menu press power button to shut off
5. the mod Overtime Protection Power Off screen Setting Vapor Setting Screen Setting Choose Screen Setting on Primary Menu press power button to enter the secondary menu to set time for screen display Overtime Protection 1min Power Off Screen Setting Vapor Setting NN ow Press to adjust time from 1 minute to 99 minutes then press power button to return to the primary menu Vapor Setting Choose Vapor Setting on Primary Menu Press power button to enter the secondary menu Overtime Protection Power Off screen Setting Vapor Setting Use to choose vape mod then press power button to select time setting on next sub menu Adjust vape time from 1s to 10s by button Cycle count from 1 to 300 times Press power button back to previous menu Next choose option exit and press power button to return to the primary menu Auto Vape TS Auto Pause 5S Cycle Count 010 Exit Auto Vape 7S Auto Pause 5S Cycle Count 010 Exit Exit Use to choose Exit mod and press it to return to the primary menu Puff Info Choose Puff Info on Primary Menu Press power button to enter the secondary menu Overtime Protection Power Off Screen Setting Vapor Setting Puff Info Power Setting Device Exit Total Puffs 00099 Total Time 00 08 20 Reset Puff Exit Secondary menu Total Puffs Display the total puffs of smoking Total Time Display the total time of smok

Download Pdf Manuals

image

Related Search

Related Contents

Manual do Utilizador da UltraView 1.3MPX HD 18X PTZ  Recommandations sanitaires pour les  Rextar user and install guide  iCN 500 - Navman  Korg R3 User's Manual    Éléments de langage des données Richard Winter, Jeffrey  GT15 External I/O Unit (Positive Common Input  

Copyright © All rights reserved.
Failed to retrieve file