PI-CONNECT OPC+ Interface User manual V3.8a
Contents
1. z a Miniprj MCP maaa o a letzte nderung 3 zeiten JJ Prozesswertarchiv Prozesswertarchiy 11 25 2003 02 32 55 PM Ww Archive J Prozesswertarchiv2 Prozesswertarchiv 10 01 2004 04 52 17 PM Archivkonfiguration _Wey blenname __ Prozessvariable N variablentyp _ Kommentar_letzte Anderung__JErfessungsart_ var O igRM_MASTER RM_MASTER 11 25 2003 02 32 5tzyklisch kontinuierlichSy lt Fi a 01 28 2004 05 59 3 zyklisch kontinuierlichSys It E 01 28 2004 05 59 3 zyklisch kontinuierlichSys read_DB3_1 11 25 2003 02 32 5izyklisch kontinuierlichSy lt read_DB3_2 03 25 2004 04 05 5 zyklisch kontinuierlichSys read_DB3_3 11 25 2003 02 32 5tzyklisch kontinuierlichSy lt read_DB3_4 11 25 2003 02 32 51 zyklisch kontinuierlic Sy read DESAY 11 25 2003 02 32 51 zyklisch kontinuierlic Sys read_Merker_1 11 25 2003 02 32 51 zyklisch kontinuierlic Sys read_Merker_2 11 25 2003 02 32 51 zyklisch kontinuierlic Sys read_Merker_3 11 25 2003 02 32 51 zyKlisch kontinuierlichSy lt read_Merker_4 11 25 2003 02 32 5tzyklisch kontinuierlichSy read_Merker_5S 11 25 2003 02 32 5izyKlisch kontinuierlic Sys ariablen 28 512 For this example the entries in the file SiOPC_IF ini would be Archive_1 Archive_2 Siemens Pl Connect OPC Interface User manual local Prozesswertarchiv local Prozesswertarchiv2
2. Supported features Signup for Updates Yes Exception Reporting Yes Required software and licences Yes PI Interface API SDK from OSlsoft LLC Please check conditions and terms with OSlsoft LLC As an option the PI Interface API SDK can also be delivered by Siemens PI SDK versions tested and PI SDK V1 3 8 and V1 4 0 recommended PI API is included Required software and licences Maybe OPC DA and OPC HDA server has to be from the vendor of the DCS checked with the vendor of the DCS Operating systems tested by us Windows XP Windows 7 x86 and x64 Windows 2003 Windows 2008 Windows 2008 R2 Archive Recovery Yes as option for PCS7 V6 also manual mode for disaster recovery available Addon Failover Online Yes as option but not in combination with Archive Recovery Pointclass Classic Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 9 of 47 SIEMENS 1 4 Features of the interface Using the recommended configuration refer to chapter1 2 1 and a redundant PCS7 server a data rate of 2000 values per second could be achieved in a test An Intel P4 PC 2 4 GHz has been used for the test Attention The communication between the Automation system AG and the PCS7 server may be a bottleneck In configurations with redundant AGs lower performance is possible Also an overload of the channel has been detected The spreading of the data rate to i the separate AGs has to be kept in m
3. it is possible to add further intervals please refer to chapter 5 3 Configuration of acquisition cycles Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 14 of 47 SIEMENS 3 4 PI System Parameters Listed parameter are applied to configure the coupling to the PI system as well as to control the behaviour of the OPC IF interface towards the PI system Type Parameter Explanation Ob PIHost PI_SERVER PI Server to be connected Ob PointSource kkkkkkkk Point Source character to assign the PI point to the interface max 8 characters no Upper Lower case determination Ob lORateTag ior_OPC_IF_1 Tag where a recording rate values per second average of ten seconds of the interface is stored For each instance a separate tag should be used OpZ UpdateDelay 30 Period in seconds to wait for point updates to be taken in processing by the interface Range of values Recommended 0 120 seconds gt 30 seconds OpZ PIAPIVerbose 1 Display use of PI API 0 no display 1 only errors 2 proceeding of any function Recommended 21 Op USESDK 0 0 Configuration parameters are read using API 1 configuration parameters are read using SDK slower 3 5 OPC DA OPC HDA Parameters These parameters are used to define the linking to the OPC server of a stand alone PCS7 server or to both OPC server of a redundant PCS7 server pair Please
4. PI numeric is done After this the conversion PCS7 numeric gt PI digital is done 5 10 3 Data Type Conversion of writing points Conversion of writing points is done according to the rules for reading Points with the exception according chapter 5 10 4 Writing to OPC Variables of Data Type VT_BOOL 5 10 4 Writing to OPC Variables of Data Type VT_BOOL OPC Bool variables are mapped to 0 1 in PI not to 0 1 For easier writing of Bool Variables to the OPC server the following conventions are implemented Writing Bit to OPC server PI Int16 Int32 digital are written bit masked as VT_I4 if the ExDesc contains BIT 0 BIT 15 Writing Bit to OPC server PI Int16 Int32 digital are written bit masked as VT_Bool if the ExDesc contains BIT 0 BIT 15 To write a value stored in PI as 0 1 in a PI digital Int16 or Int32 to an OPC variable of type VT_BOOL the ExDesc entry must be as follows ItemID lt OPC Item ID gt BIT 1 Read PI values and write to PCS7 Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 30 of 47 SIEMENS 5 11 PI Point States used by the interface Instead of a value a PI Tag may show a state containing additional information to a missing value The following PCS7 Errors have associated PI States for the affected Point Possible reason PI state PCS7 Server not within reach PCS7 Variable not found breakdown Bad Quality of connection to PCS7 server A
5. the process data transfer between the DCS and the PI interface will run only on data changes Due to that the DCS has a low load For the cyclical supply of the PI exception test check for horizontal value changes events with current time stamps were built see section 5 4 Special feature on time stamping In the PIL CONNECT OPC interface a mechanism is implemented which can handle the switch over of the two redundant OPC servers itself option The special features of PCS7 Win CC OPC DA server Time stamp correction launch behaviour and status handling were considered and prepared in PI for an optimized representation Further features of the PIL CONNECT OPC Interface are e The interface supports PI HA e Archive Recovery can be launched manually also in case of need manual input of the time range which has to be filled out of the archives See also chapter 5 12 HDA Window Recovery Mod e The optional PI CONNECT Config Tool supports the users configuring and maintaining the tag configuration with PCS7 connection e To use large character strings in the PI tag configuration e g for the OPC item name PI CONNECT OPC can use the PI SDK USESDK configuration parameter Please regard for the installation of the PI CONNECT OPC interface that one instance of the interface connects one PCS7 server or server pair That means for each server or server pair one instance of the interface has to be installed and licensed For furthe
6. 0 1 2 3 will be written to Pl This is a relevant help in designing digital sets within PI The shift option is activated in adding the keyword SHIFT 1 separated by a semicolon to the bit mask 5 7 Scaling The OPC IF supports scaling of values received from the OPC server The function is activated by setting the location2 attribute of the PI tag to 1 The attribute UserReal1 contains the value of the factor in UserReal2 the value of the offset is configured Please refer to chapter 6 PI Point configuration The value transmitted to the PI server is calculated as follows Value PI OPC value UserReal1 UserReal2 Value PI OPC value factor offset 5 8 Replacement tables for digital conditions To alleviate the data acquisition for PI Points of type digital replacement table can be defined in the configuration file see Chapter 3 6 1 Replacement tables for digital conditions DigiCodeTable In these tables a definite number of OPC process values can be defined to PI status values lt 0 system otherwise Digital Set All not itemised process values are defined with the value default To net this function for a point the replacement table has to be defined in the configuration file before creating the PI Point At create the PI tags the number of the replacement table is deposited in UserInt1 If a replacement table is not required the value 0 has to be placed there Siemens Pl Connect OPC
7. 4 2014 Lutter V3 8a V3 8 5 correction of SHIFT parameter OPCStringMode 3 Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 47 of 47
8. Account a PI user and with it also the access rights are assigned to an IP address of an interface If the user shall not be an existing user please create a new one as follows Launch the System Management Tools PI SMT in Start gt Program Files gt Pl System and create a new user in Security gt Identities Users amp Groups with a right mouse click Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 43 of 47 SIEMENS System Management Tools Search p Alarms Batch Data E Interfaces E IT Points Operation E Points Security Database Security Firewall Identities Users amp Groups Mappings amp Trusts Security Settings For PI server V3 3 versions For this start piconfig piiadm piconfig exe on the PI Server and execute the following table piuser mode create istr user groups siemens piadmin ends exit REMARK Ifthe Interface is desired to run as PI User piadmin the piconfig commands listed above are not necessary For the Proxy Account PI Trust Entry piadmin has to be entered instead of siemens For additional information to the commands and functioning of PlIConfig refer to the manual PI Data Archive of OSI Software You may use PI SMT3 to create groups and users as well 8 3 Pl Trust entry on the PI server To run the interface software without problems a PI trust entry is needed in former times Proxy A
9. First the operating system has to be set to start up with the Autologin This means a user is logged in automatically without any interaction As a consequence programs located in Start gt Program Files gt Start up will be executed Login and Password of this user must be identical with the operating system user of the PCS7 server To set up the Autologin contact your system administrator or make use of the tool LockWorkStation included in the interface software delivery Starting with Windows 2000 the workstation may be locked directly after the login with this tool 2 Creating a Batch File For automatic start up of the interface instances after the Autologin a batch file e g named Start bat has to be created The Windows text editor e g notepad may be used for this The file should have the following structure echo off echo Start job of die SiIOPC Interfaces rem wait 1 minute call wait 60000 rem start the 1 interface Instance start C Programme Siemens SiOPC SiIOPCIF exe 01 rem for 2 instance only rem wait 30 sec rem call wait 30000 rem start 2 interface Instance rem start C Programme Siemens SiOPC SiIOPCIF exe 02 Start bat file for automatic start up after system start up Adjust paths and further instances on your requirements To use the command wait requires copying the file wait exe to the system directory e g c windows The file is included in the delivered interfa
10. If the value of the source point is out of range of an unsigned 32 bit integer the PI value is set to OVERRANGE res UNDERRANGE The bit mask may be given binary max 32 digits hexadecimal max 8 digits or decimal 0 4294967295 separated by a blank following the PCS7 Variable name in the ExDesc The keyword BITMASK and the format key Ox res Ob are case sensitive The first character of Ox and Ob is the numeral null Examples BITMASK 0b1 100 Binary bit mask Bit 2 and2 will be selected Only the decimal values 0 4 8 12 may be written to PI BITMASK 0xf0 Hexadecimal bit mask The bits 2 to 2 will be selected and only the decimal values 0 16 32 48 64 70 86 102 118 134 150 166 182 198 214 und 230 may be written to PI BITMASK 10 Decimal bit mask The bits 2 and 2 will be selected The following values may be written to PI 0 2 8 and 10 Optionally it is possible to do a right shift on the masked double word to set the first selected bit to the position 2 This is helpful if e g the bits 2 and 2 are selected BITMASK 0b1 1000000 Without the shift option the values 0 64 128 196 may be written to PI With the shift option BITMASK 0b1 1000000 SHIFT 1 it will be shifted 6 positions to the right because 2 is the lowest with the mask selected bit Therefore the bits 2 and 2 will turn to 2 and 2 and with this the gapless with zero starting values
11. Interface User manual V3 8a August 4th 201 Page 26 of 47 SIEMENS 5 9 Archive Recovery OPC HDA optional 5 9 1 5 9 2 General and requisites The option Archive Recovery of the OPC IF is able to use this way HDA to close the gap in the data since the last shutdown of interface on start up e g after service works on the interface PC or the network Prerequisites to use the archive recovery function are e PCS7 Version V6 0 or higher with licence for OPC HDA server e Siemens Pl Connect OPC Interface with the license for option archive recovery HDA e The tags must be defined in the PCS7 process value archive Functionality Starting with PCS7 version V6 0 the PCS7 Server precisely WinCC supports an OPC HDA server besides the OPC DA server Via the OPC HDA server the process value archive of the PCS7 server may be accessed The option Archive Recovery of the OPC IF may use this way to close the data gap since the last shutdown on start up e g after service works on the interface PC or the network The interface detects the time stamp of the last value in the PI archive and asks for values out of the PCS7 system starting with that time When the actual system time is reached data collection is switched over to OPD DA Because OPC DA is signed up in an early stage the switching gap will be lt 5 seconds The archive recovery function may be activated for each PI tag separately _ For each PI tag that u
12. Location3 IO Type e Location4 Scan Class defined in SiOPC_IF ini e Location5 Number of PCS7 archive defined in SiOPC_IF ini e InstrumentTag PCS7 archive variable name e Userlnt1 replacement table e UserRealt scaling factor e UserReal2 scaling offset e SourceTag Source tag for Output Points This documentation only covers the interface specific attributes For Pi point configuration additional attributes have to be set For a detailed description of PI SMT PI Point Database and their attributes please refer to the system documentation of the PI System 6 3 PointSource Attribute The PointSource Attribute for OPC IF points may be P for PCS7 O for OPC etc This parameter assigns PI Points to the OPC IF It must correspond with the parameter PointSource in the SiOPC_IF ini file The assignment to the particular instance of the PCS7 interface is produced via the attribute Location1 Only values with a maximum of eight characters are supported for the PointSource Upper Lower case are not differentiated Please keep in mind that some values may be occupied by the PI Server itself e g C for Performance equations and others may be occupied by further already existing interfaces Please consult your PI Administrator to appoint that value Caution is advised if an interface used on the PI Serve supports only single character point sources If such an interface is set to PointSource A for excample it will try to
13. OS server pair If the PI CONNECT OPC Interface shall handle itself switching between redundant OPC servers an according license is needed Archive Recovery is an option for the PL CONNECT OPC Interface which is needed only once for each Interface PC Not redundant PCS7 OS servers as well as PCS7 OS Stations respectively redundant pairs of PCS7 OS Stations are treated like a redundant PCS7 OS server in by the PI CONNECT OPC Interface For each instance of the PI CONNECT OPC Interface a license file is needed for correct operation For generation of this license a tool is provided which must be run on the PI interface PC to collect the data necessary for the generation of the license file Those data must be send to us by email The license file is returned by email thereafter Installation test and evaluation of the PI CONNECT OPC Interface may be done with the emergency licence provided with the delivery refer to section 3 2 3 Emergency function Thus the needed license file may be ordered with the date of productive use of the PI CONNECT OPC Interface whereby start time of the service contract will also not be until that date Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 10 of 47 SIEMENS 2 Install und Uninstall 2 1 Requirements for the Installation To install the OPC IF successfully the following requirements are necessary e Operating system depends on the release of PCS7 Please
14. PC and the PCS7 Server PCs as follows Start with Start gt Run gt comenfg the DCOM configuration Quit eventually occurring messages Select the folder Default Security of the DCOM configuration You will find three buttons to adjust the Default Access Permissions Default Launch Permissions and Default configuration Permissions Make sure for all 3 points the users System Interactive and the group Administrators to have the maximum rights For example here the dialog for the Default Access Permissions Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 40 of 47 SIEMENS Registry Yalue Permissions E x Registry Value Default ccessPermission Owner Administrator Name Administrator Allow Access Ga INTERACTIVE Allow Access K SYSTEM Allow Access Type of Access JAlowAccess o Cancel Add Remove Help For further possibilities in configuration please refer to the OPC Foundation the PCS7 documentation und die Help function of the Operating System 7 3 Identification of the WinCC Process value archives The entries for the process value archives in the file SiOPC_IF ini must look as follows lt prefix gt lt archive name gt The archive names may be seen directly in the WinCC Explorer s Tag Logging The process variable name corresponding to the archive variable may also be found here ioixi Datei Bearbeiten Ansicht
15. PCS7 we strongly recommend to activate these parameters Changes on the standard settings should only be done upon advice by us The parameters are OPCS7WAMaxReadds 3 number of Re add trials OPCS7WAReaddQualityCode 4 OPC error code OPCS7WAReaddDelay 25 Re add Delay in seconds Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 35 of 47 SIEMENS 6 PI Point configuration 6 1 Automatic configuration tool option For this interface an automatic configuration tool is available A user defined filter is set up on the PCS7 module level Thereafter the PI tag configuration is created automatically On any change if the PCS7 configuration the necessary changes for the PI configuration may be created in so called delta runs For further information please refer to the documentation of the configuration tool Sa Only structure tags are recognized by the confiration tool The means that the variables YD have to be parameters if a WinCC structure type This is the fact for all PCS7 sturcture tags normally 6 2 Siemens OPC Interface specific attributes PI Point Configuration is done using the PI System Management Tool PI SMT Add In for MS EXCEL Only the specific features of the PIL CONNECT OPC Interface to addressing and conversion of the variables are mentioned here e PointSource Assignment to PCS7 Interface e ExDesc PCS7 Tag e Location Assignment to instance e Location2 Scaling on off e
16. able to handle the redundancy of the PCS7 OS servers or WinCC servers The PLCONNECT OPC interface uses the OPC DA server which is part of every PCS7 WinCC OS server For the option Archive Recovery of the PIL CONNECT OPC on each PCS7 OS or WinCC server a license for the OPC HDA server is needed Therefore the WinCC Connectivity Pack assigned to its WinCC or since PCS7 V7 1 the Open PCS7 for PCS7 OS clients on each PCS7 OS server can be used PI Client PI Client DataLink PI SMT Ethernet network This configuration can also be used for PCS7 V7 8 PI Client ProcessBook PI CONNECT OPC Interface PC OSI Soft PI API PI SDK Plant Information System Server V3 4 Siemens Pl Connect OPC Interface Ethernet network Pear to pear connection recommended OS LAN Terminal bus OPC DA HDA OPC DA HDA OPC DA HDA SIMATIC PCS7 OS SIMATIC PCS7 OS SIMATIC PCS7 OS Server Server Server l ll III Redundant Redundant Redundant PROCESS Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 8 of 47 SIEMENS 1 3 Performance The PI CONNECT OPC interface supports queued sending to PI queued send to snapshot API bode buffering und Auto reconnect after connection loss to the PI server or to the process control system Redundancy of the PCS7 Systems is supported Redundancy switching is done by the PI CONNECT OPC interface option Supported features
17. of a SIMATIC PCS7 Server The SIMATIC PCS7 server may be configured redundant This means the server software is installed on two PCs and is active on both PCs at the same time SIMATIC PCS7 clients interact to such a redundant pair using PCS7 internal mechanisms The WinCC OPC servers on the other hand act as two stand alone OPC servers providing identical data content The Siemens OPC Interface is designed to access such a redundant server pair For further information on the functionality of the redundant access refer to chapter 5 2 Connecting to redundant PCS7 OS redundant OPC server 7 2 Access to the OPC Server Remote access via DCOM An OPC Server exists as a COM Server COM is an object model from Microsoft to develop distributed applications Access takes place by operating system libraries With the extension of COM DCOM distributed COM access is possible beyond the computers To do so it is necessary for the users logged in on the computers to grant rights to one another Furthermore client and server PC have to be in the same domain or in the same workgroup Please refer to the demands of the respective PCS7 version We suggest configuring the client PC as far as possible like a PCS7 client That is e Same operating system including Service pack and Hot fix e Same operating system login and password member of the group administrators e Same Workgroup Furthermore we suggest expanding the DCOM access rights on the interface
18. of re add trials of a variable Refer to Chapter 5 19 OpenPCS 7 Workaround Op OPCS7WAReaddQualityCode 4 OpenPCS7WorkAround OPC error code Refer to Chapter 5 19 OpenPCS 7 Workaround Op OPCS7WAReaddDelay 25 OpenPCS7WorkAround Delay between two re add trials Refer to Chapter 5 19 OpenPCS 7 Workaround 3 6 Global Parameters for all instances valid 3 6 1 Replacement tables for digital conditions DigiCodeT able It is possible to define Replacement tables for digital conditions In these tables a PI status value is dedicated to a hexadecimal OPC process value These can be values from a digital Set gt 0 or values from a PI system status lt 0 For not having to itemise every single process value a Default Value can be defined which is used whenever no entry for the OPC process value exists in the table The replacement table starts with an own section DigiCodeTable_xxx xxx stands for the number of the table Tables from 001 till 999 can be defined When you enter the number in PI Tag in UserInt1 the tables are referenced Therefore see Chapter 5 8 Replacement tables for digital conditions Example for a replacement table DigiCodeTable_001 Code_def 255 Code_001 0x00 4 Code_002 0x01 3 Code_003 0x02 2 Code_004 0x03 1 Code_005 0x04 0 Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 17 of 47 SIEMENS 4 Starting and terminating of t
19. refer to release notes of PCS7 OS clients e Operating system login of the interface PC and the PCS7 servers must be identical also for the PCS7 OS clients e Option Archive Recovery starting with PCS7 Version 6 License for OPC HDA server e Open PCS7 server installed on the interface PC e Connectivity Pack assigned to the right WinCC installed on every PCS7 OS server e or since PCS7 V7 1 Open PCS7 for PCS7 OS clients on every PCS7 OS server e Installation of the PI SDK including PI API Version see section 7 3 Performance Hints refer to section 8 Hints for API Installation and PI Server Configuration e PCS7 Server Pl Server and Pl Interface PC must be time synchronised by the same source 2 2 Installation of the Interface Software It is important to read the installation hints in the readme txt file included in the delivered installation files before installation of the OPC IF The file may contain important installation tips For installation of the OPC IF proceed as follows e Call the file setup exe in the directory SETUP of the delivered software e Follow the installation hints of the installation procedure e Edit the SiOPC_IF ini file according to your needs Refer to section 3 Configuration e The OPC_Core_Components msi is copied to the installation path during installation If you experience problems on the first start of the interface install the OPC core components 2 3 Uninstall To uninstall
20. take in regard especially the parameters mentioned in Chapter 5 16 Controlling of the OPC connection via an OPC test Item Type Parameter Explanation Ob MasterOPCServer ProgID of the first respectively stand alone OPC DA server For the OPCServer WinCC PCS7 WinCC OPC DA Server the ProgID always is OPCServer WinCC Op SlaveOPCServer ProgID of the redundant partner In case of a stand alone OPC Server this OPCServer WinCC values should be omitted Please refer to chapter 5 2 Connecting to redundant PCS7 OS redundant OPC server For the PCS7 WinCC OPC DA Server the ProgID always is OPCServer WinCC Ob MasterOPCServerHost Computer name of the PC where the MASTER OPC DA server is installed Serv1 Op SlaveOPCServerHost Computer name of the PC where the SLAVE OPC DA server is installed Serv2 This value only has to be set if a SlaveOPCServer is defined Also refer to chapter 5 2 Connecting to redundant PCS7 OS redundant OPC server Op MasterHDAOPCServer ProgID of the first respectively stand alone OPC HDA Servers For the OPCServerHDA WinCC PCS7 WinCC OPC HDA Server the ProgID always is OPCServerHDA WinCC Op SlaveHDAOPCServer ProgID of the redundant partner In case of a stand alone OPC Server this OPCServerHDA WinCC value should be omitted Please refer to chapter 5 2 Connecting to redundant PCS7 OS redundant OPC server For the PCS7 WinCC OPC HDA server the ProgID always is OPCSe
21. the OPC IF carry out the following steps e Terminate all instances of the PIL CONNECT OPC interface e Delete all shortcuts referring to the file SiOPCIF exe e Uninstall the software like any other Windows software The configuration and log files and the installation directory are not deleted by the uninstall procedure and may be deleted manually afterwards Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 11 of 47 SIEMENS 3 Configuration 3 1 Structure of the file SiOPC_IF ini The configuration of the PCS7 Interface proceeds by setting the parameter in the SiOPC_IF ini file which has to exist in the Windows NT home directory normally C WINDOWS The SiOPC_IF ini file is divided into sections Each section starts with XX XX indicates the number of the section Via this number various instances of the OPC IF receive individual parameter sets Each instance interlinks to one PCS7 server That means for each PCS7 server one instance of the interface must be configured The section number always has to be indicated with two digits e g 01 or 12 Each section contains 4 blocks of parameters These are e License settings only for elder versions e general parameters e Pl system parameters e OPC parameters Parameter may be compulsory optional or constant Compulsory parameter must be indicated Optional parameters are substituted by standard values if they are not indicated Con
22. 15 17 10 15 35 10 15 52 2 10 15 00 10 15 17 10 15 35 10 15 52 To avoid those reproducing problems in the PI archive the Pl Connect OPC Interface does some corrections The Pl Connect OPC Interface itself provides cyclic values in the scan cycle of the PI API and delivers a corrected actual time stamp if needed Leaps in time resulting of PCS7 Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 24 of 47 SIEMENS server redundancy switches have to be taken in account in doing so To avoid faulty values caused by cycle imprecision it may be necessary to suppress the value for one scan cycle for measure points which run constantly for at least two scan cycles Therefore it is an absolute must to have the PCS7 Server the Interface PC und the PI Server synchronic in system time If this can not be assured we recommend to use the local time of the Interface PC for time stamping of the values sent to the PI System In the following example is shown how the value changes received from PCS7 are forwarded cyclically to the Pi API and how the first level compression of PI System exception test works Scancylce 1s ExMax 600 ExDev 0 5 Time New Value Sent to the API Value sent by the PI API to stamp out of by the interface the PI Server Snapshot table PCS7 uses time stamp of column 00 00 00 3 3 00 00 01 3 00 00 02 3 00 00 03 3 00 00 04
23. 24 5 5 Writing PI data OnDataChange neen 25 OG eane EE aoe estes fai iss eed leaned tec pec tet Spicote dd poe ede tyne Sede aae Meme patentee 26 Dai OAM n an a aor oon Nt dian N A nia onen hoch 26 5 8 Replacement tables for digital conditions cceeeeeeeeeeeeeeeeeeeteeeeeeeeeeeeteees 26 5 9 Archive Recovery OPC HDA optional ceecceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 27 5 971 General and Tequisites mienens ane a aiaia 27 Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 3 of 47 9 2 PUMCHONAIILY ssetattctet a a a sesh E EA 27 59 3 POMOMMANCG iascia cia eee acts kak dete inetd tite tees sade 28 5 9 4 Archive recovery system lOad cccceeeeeeeeeeeeeeeeeeeeeeeeeeeeseeeaeeeeeeeeeeeeeeees 28 5 10 Supported Data Types and their conversion eeeeeeeeeeeeeeeeeeeeeeeeeeeeees 29 5 10 1 List of supported Data Type its hers asice tustctessaasvtascees taedkesekavahae pte heseeareeetaes 29 5 10 2 Data Type Conversion for reading Points c c cccceeeeeeeeeeeeeeneeeeeeeeeeeeeees 29 5 10 3 Data Type Conversion of writing points e cece eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 30 5 10 4 Writing to OPC Variables of Data Type VT_BOOL 0 eee eeeeeeeeeeteeeeeeeeeteees 30 5 11 PI Point States used by the interface 0 eeeececeeccceee eee eeeeeeeeneeeeeeeeeeeeeeeees 31 5 12 HDA Window Recovery Mode ccccceeeee
24. 3 00 00 05 3 3 00 00 06 5 5 5 00 00 07 5 00 00 08 5 5 00 00 09 8 8 8 00 00 10 8 00 00 11 8 00 00 12 8 8 00 00 13 2 2 2 00 00 14 2 00 00 15 2 00 00 16 2 5 5 Writing PI data OnDataChange Usually it is required to configure a point as a reference This reference point possesses the PointSource of the OPC IF and includes the required parameter for the connection to the PCS7 server The attribute source tag of this reference point makes contact to the source point whose data are transmitted to the PCS7 server All values transmitted from the source point to the PCS7 server are stored in this reference point The reference point contains a copy of all the source point s data which were sent to PCS7 If it possible to assign the PCS7 interface s PointSource to a source point and to store all required parameters in its attributes the reference to another source point is not needed The attribute SourceTag has to be assigned to the tag itself in this case Copying of the sent data is avoided in this case Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 25 of 47 SIEMENS 5 6 Bit masking It is possible to select a single bit or a group of bits out of the value using a 32 bit mask refer to chapter 6 PI Point configuration For this the PCS7 source variable is converted into a 32 bit unsigned integer Post decimal positions of float variables are truncated not rounded
25. 5 Function of the Siemens OPC Interface 5 1 Scope Reading process values Process values are read cyclic out of the Data Manager internal and external variables of a PCS7 server in up to 30 free definable cycles However the cycles are adjusted to the cycles of the OPC server please refer to chapter 5 3 Configuration of acquisition cycles In the online mode using OPC DA mode the process data transfer between the DCS and the PI interface will run only on data change Due to that the DCS has a lower load For cyclic supply of the PI exception test check for horizontal value changes events with actualized time stamps are built see section 5 4 Special feature on time stamping Either the stamps out of the process control system or local time if the Interface PC may be used Writing process values Data out of the PI System may be written to PCS7 variables in the Data Manager Writing is done event based OnDataChange whenever the source point of the PI system delivers a new event Archive recovery via OPC HDA optional For PI points using the function the data gap since the last run of the interface is closed by the interface software To do so the values are read out of the process value archives of the PCS7 WinCC servers via the OPC HDA Server Archive Recovery is an option of the interface software and must be licensed separately to use the option Connection check The connection to the PCS7 server an
26. PCS 7 system is connected to a PI System via OPC and variables to be transmitted to the PI system were deleted in the PCS 7 data we strongly recommend not to use Delta Loading of the PCS 7 OS This is valid as well if the variables are created again directly after deletion Using Archive Recovery in combination with running an OPC HDA Servers directly on the PCS 7 OS via the WinCC Connectivity Pack or the OpenPCS 7 Client may cause the OPC HDA Server not the recognize the newly defined archive variables in the process value archive Because the interface tries to do Archive Recovery starting with the latest PI archive value for new PI tags having archive recovery assigned correct writing of data to the PI archive should be checked for those tags after creation Otherwise it may be that the OPC HDA Server does not provide data fort he new PI tags To avoid failures the interface does not switch to OPC DA mode and removes this Variable from cyclic scanning In this case a restart of the PCS7 OS Servers and reassigning of the tags in the interface may be necessary Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 42 of 47 SIEMENS 8 Hints for API Installation and PI Server Configuration 8 1 Pl interface SDK API Software installation The interface should be used with PI SDK version tested and released by us Please refer to chapter 1 3 Performance The PI SDK Setup includes the installation of the PI API A detai
27. PI CONNECT OPC Interface incl Option Archive Recovery User manual V3 8a Siemens PI CONNECT OPC Interface to Plant Information System PI of OSlsoft LLC Siemens AG GER I CS MTE MHM Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 1 of 47 Version V3 8a dated April 30th 20134 Contact Telephone Fax Email Address 0621 456 2303 0621 456 3334 info rhm industry siemens com Siemens AG GER I CS MTE MHM Hr Lutter Dynamostr 4 D 68165 Mannheim Germany Subject to change without further notice nderungen vorbehalten 2003 2014 Siemens AG GER I IS MTE OC MHM All rights reserved Dynamostr 4 D 68165 Mannheim Germany Trademarks PI is Trademark of OSIsoft LLC Microsoft EXCEL Microsoft Windows NT and Microsoft Windows XP Windows 7 are Trademarks of Microsoft Corporation Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 2 of 47 Contents Bhs BAVET AVILE A corte rato aaetd teenie E A 5 TA Generalsin a cree Mol A S 5 1 2 Exemplary configuration cccccccceceeeeeeeeeeeceeeeeeeeeeeeeceeceeeeeeeeeeeeeeeeeennieeeeeeees 6 1 24 POST via Open POST wtiase ae Ae Aaa a era Aree nas A aei 7 1 2 2 PCS7 WinCC via WinCC OPC Server cccccceceeeeeeeeeeeeeceeeeeeeeeeeeeeeneeeeeeeeeees 8 T3 Performance nres a a a a aaa aa aaa a ania na 9 1 4 Features of the interface esessseeeeeeseeseeernrnrereerrttrnntttreorrt
28. S not within reach of PCS7 server Error by reading the PI Point configuration or no access rights to Error PCS7 variable PCS7 configuration Value exceeds range of PI Pointtypes Over Range Value falls below range of PI Pointtypes Under Range All other faults Bad The following states of the interface result in the shown PI States for all Points of the interfaces Possible reason PI state Interface start up Scan On Interface shut down Scan Off Loss of the connection to OPC server Scan Timeout Re establishment of the connection to OPC server Scan On The interface has the option to define in the ini File the correlation between the OPC quality flags and the PI Point states resulting thereof The following quality flags from OPC are supported OPC Quality Flag PI Status Bad If the ini File parameter ValueState_Bad is not set the state 255 quality code 00xxxxxx BAD VALUE is sent else the PI state according to the value of the ini file parameter Uncertain If the ini File parameter ValueState_Uncertain is not set the state 0 quality code 01xxxxxx OK is sent else the PI state according to the value of the ini file parameter Good Always 0 OK quality code 1 1xxxxxx The default values ValueState_Bad 255 and ValueState_Uncertain 0 match to the behaviour of elder versions Siemens Pl Connect OPC Inter
29. This has to persist if the interface will run as a service too Register configure and operation of an Instance as a service For registration of the instances 1 5 as a service the interface software creates shortcuts in the installation path of the interface e g C Program Files x86 Siemens PI CONNECT OPCPlus Stand alone However if instances with numbers gt 5 shall be registered the following command can be used SiOPCIF i nn where nn Instance number 01 to 99 After registration the following service can be found in the windows service manager Display name PI CONNECT OPC Interface Standalone nn Service name PI_CONNECT_OPCPlus_Interface_SA nn Nn means the instance number too Thereafter the service may be configured using within the Windows services Usually the following parameters are set User account for the service refer to chapter 4 5 1 General Startup type manually or automatically Recovery For the last item we recommend to use the windows option which restarts the service after failure User account and startup type to be used depend on the intended use Added two recommended examples Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 20 of 47 SIEMENS 4 5 3 Configuration 1 local connection to an Open PCS 7 OPC Server User Account corresponds with the Windows account of the PCS7 client stations This is often identical with the Windows account
30. V3 8a August 4th 201 Page 41 of 47 SIEMENS To determine the prefix and the check the archive access we recommend to use the tool Blopc_archive exe delivered with the interface It is recommend to operate the tool directly on the OS Server The EXE file may simply be copied and started fort his purpose Launch this program and follow the instructions on the display Programm zur Bestimmung der vorhandenen Archive bzw Tags A A TARTU an ete eT ToT OR TRU TT Application require PCS Server performance Do not use in critical situations Host des OPC Servers eingeben Bitte 1 eingeben fuer localhost SS ProgID des OPC Servers eingeben Bitte 1 eingeben fuer OPCServerHDA WinCC Sil Waehle maximale Anzahl die ausgelesen werden soll empfohlen lt 100 Zahl eingeben 2 10000 gt gt 20 Running the program the file WinCCArchive log is created containing the requested archive variables including the complete path Output should look like follows Info 4 lt 2004 10 1 17 9 2 gt A 0 local Prozesswertarchiv RM_MASTER Info 4 lt 2004 10 1 17 9 2 gt A 1 local Prozesswertarchiv F 1 Info 4 lt 2004 10 1 17 9 2 gt A 2 local Prozesswertarchiv 1 Info 4 lt 2004 10 1 17 9 2 gt A 3 local Prozesswertarchiv read_DB3_1 Info 4 lt 2004 10 1 17 9 2 gt A 4 local Prozesswertarchiv read_DB3_2 The prefix of the archive name is here local 7 4 PCS 7 Delta Loading If a
31. a type whenever the source data type has a higher resolution than the destination tag data type If the value will be out of range of the PI Types the PI Points get the state OVERRANGE or UNDERRANGE Read PCS7 values and write to PI Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 29 of 47 SIEMENS PCS7 alphanumeric j and k gt Pl numeric 2 to 6 Conversion of PCS7 Types j and k to numeric Pl Types 2 to 6 tries to change the text toa numeric value The decimal delimiter is taken from the country settings of the PC If the alphanumeric PCS7 Wert does not contain a number the result is undefined PCS7 numeric a to i gt Pl alphanumeric 7 The numeric PCS7 values are converted character by character to the Pl Type String The decimal delimiter is taken from the country settings of the PC PCS7 alphanumeric j and k gt PI alphanumeric 7 Transmission of PCS7 Types j and k to the Pl Type String are done character by character without any conversion PCS7 numeric j and k gt PI digital 1 The post decimal positions of the numeric PCS7 value will be truncated no rounding to an Integer value If this values is in the range of 0 255 it will be transmitted as Digital Code to PI Values out of the range 0 255 will get the state OVERRANGE or UNDERRANGE PCS7 alphanumeric j und k gt PI digital 1 First the conversion PCS7 alphanumeric gt
32. ace software is connected to one of two OPC servers of a redundant pair If this connection is lost the interface switches into start up mode until a connection to one of the OPC servers is established A connection loss appears whenever the connected OPC server is shut down or the network connection is interrupted The state of some particular process values of the OPC server does not cause a connection loss In consequence error states on a part of the process values do not cause the interface to switch to the other OPC server The interface software activates only one connection to one of the OPC servers In case of connection breakdown the connection to the redundant OPC server will be established This may last up to a few minutes depending on the number of variables to be registered During this time no values are read 5 3 Configuration of acquisition cycles It is recommended using only acquisition cycles what are supported by the OPC Server and his basic DCS Using of not supported cycles unwanted effects may occur Using the example of PCS7 below the recommended configuration of the acquisition cycles is described Because the intervals stated here are mapped to the cycle times in PCS7 it is useful to use its cycles here too Cycle times less than 1 second are not expedient In accordance to this result the following recommended cycles PCS7 standard cycles Cycel_1 1000 optionally 1 0 Cycel_1 2 1000 optionally 1 0 C
33. all actual changes of process values reported by the OPC server Data Changes directly to the Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 23 of 47 SIEMENS PI API and in case of an constant development without changing of the process value the PI API will be supplied cyclically with the last received process value from the interface cache but with an adapted time stamp only with IO Typ 1 or 3 a In each case the transmission between OPC server and the interface is done only if i there is a change of the process value On Data Change The interface ensures itself the cyclical feeding of the PI API using his internal cache Thus the load for the OPC server and the subjacent process control system DCS will be minimized Cycles 1 to 10 are PCS7 standard cycles and can not be changed in PCS7 Cycles 11 to 15 are user specific cycles which may vary They should be adjusted in the file SiOPC_IF ini according to the actual settings in the PCS7 server Process values may be read cyclically from a PCS7 server in 30 free adjustable cycles These cycles have to be defined in the section of the SiOPC IF ini file belonging to the interface instance please refer to chapter 3 Configuration These times specify the cycle to order the values from the OPC server The WinCC OPC server maps these requests to the 15 cycles of the PCS7 WinCC server Cycles not contained in the list of the 15 PCS7 server cycles are mapped
34. and used instead of the PI Buffer Server This configuration is as recommended by OSlsoft The interface software is tested successfully in this constellation with the following software releases e Pl Server V3 4 380 36 e Pl Buffer Subsystem V3 4 375 84a e PI SDK V 1 3 8 387 e PIAPI V 1 6 1 15 Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 45 of 47 SIEMENS Primary Secondary PI Server PI Server PI Interface PC PlIbufss PI SDK API PI Connect OPC Interface The settings in the ini files of the PI API Pilogin ini Piclient ini and of the SDK must be in accordance to the OSI manuals of the PI HA Server the PI Buffer Subsystem and the interface installation manual It is recommended to use PI ICU to create the settings Differing settings may cause malfunction in data transmission Pre processing of the data in the PI Buffer Subsystem Exception and Compression are done on the interface PC and replication of the data to multiple servers may lead to higher load on the interface PC This should be taken in account by choosing the interface PC Also take care of the fact that in case of connection loss to the Primary Server the interface comparable to all OSlsoft Interfaces does not recognize point updates and write tags Data transfer from PI to the OPC Server do not receive any values After connection return the tag configuration is automatically checked and updated the write co
35. are installation c cececeeeeeeeeeeeeeeeeeeeeeeeeeeees 43 8 2 Pl User for the PIL CONNECT OPC interface cccecceeeeeeeeeeeeeeeeeeeeeeeteees 43 8 3 Pl Trust entry on the PI server sic ctet cence eee ciedtpucehcetceeeioe care tebe oie 44 8 4 Running the Interface against a high available PI Server HA PI 45 9 Revision IGIONy see sec A hehe EA AEREE ek eth hed te Le oe ea 47 Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 4 of 47 SIEMENS 1 Overview 1 1 General The Siemens PI CONNECT OPC Interface reads process data from a Process Control System stand alone or redundant pair via OPC Data Access OPC DA and sends this data to the PI system Writing data out of the PI system to variables of the Process Control System is also supported The PI CONNECT OPC Interface provides the option Archive Recovery See also section 1 5 Option Archive Recovery via OPC HDA For best performance the Interface uses OPC HDA only to close data gaps In online mode the Interface uses OPC DA On startup of the PIL CONNECT OPC interface or after a reconnect of the connection to the process control system the data gap can be closed out of the archives of the process control system For the option Archive Recovery the access to the archives of the process control system via the OPC Historical Data Access OPC HDA server is necessary In the online mode using OPC DA mode
36. ccount Launch the System Management Tools PI SMT in Start gt Program Files gt PI System and create a new trust in Security gt Mappings amp Trusts with a right mouse click System Management Tools Alarms Batch Data E Interfaces E IT Points Operation E Points E Security Database Security Firewall Identities Users amp Groups Mappings amp Trusts Security Settings Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 44 of 47 SIEMENS PiTrust for PI Server V3 3 Please configure the settings with the piconfig tool pi adm piconfig exe on the PI server as follows table pitrust mode create istr trust ipaddr ipmask piuser pcs trust 172 19 17 12 255 255 255 255 siemens ends exit The access rights of all PI Points belonging to the interface should be configured as follows these are minimal access rights Interface uses the PI User piadmin Security settings since PI Server version 3 4 380 piadmin A r w piadmins A r Example for older PI versions PtAccess PtGroup PtOwner DataAccess DataGroup DataOwner O rw g w Piadmins Piadmin o rwg rw piadmins piadmin 8 4 Running the Interface against a high available PI Server HA PI The interface is tested and released with a PI Collective consisting of a Primary and a Secondary Server On the interface PC the PI Buffer Subsystem has be installed
37. ce software 3 Activate Auto start Copy the batch file to the start up directory of the auto login user The path might look like C WINNT Profiles Administrator Startmenue Program Files start up With the next start up of the operating system the instances of the SiOPC Interfaces will be started automatically 4 4 Shutdown of the console application To shutdown the SiOPC IF proceed as follows e Activate the console application window e Press lt Sirg C gt to shutdown the SiOPC IF e The interface will terminate Please wait until the window of the console windows is closed Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 19 of 47 SIEMENS 4 5 Starting as Windows Service 4 5 1 4 5 2 General PI Connect OPC Interface V3 8 and higher can be started as a Windows service The necessary steps are described below Please consider always the following details If the interface OPC client shall access an OPC server remotely it has to be ensured that the user running the service has accordant DCOM access rights to the OPC server and also backwards for the callbacks of the asynchronous OPC interface This is achieved normally by using a user account for the service which is available on the OPC server too Some OPC servers e g Open PCS7 are only released to operate on a PC using a so called Autologon Therefore on such a PC a user is always logged in automatically
38. d Therefore the INI parameters OPC_NO_CALLBACK_WARNING_DELAY and OPC_NO_CALLBACK_DISCONNECT_DELAY may be set The value 0 is default for OPC_NO_ CALLBACK_WARNING_DELAY and means off The value 600 is default for OPC_NO_CALLBACK_DISCONNECT_DELAY and means warning after 10 minutes without call backs 5 16 Controlling of the OPC connection via an OPC test Item In the INI file the parameter OPCDATestltem may be defined This item will be registered at the OPC server Scancycle for this item is set with the parameter OPCConnectionTestTime If no new time stamp for this item for more than OPCTestltemTSTimeout seconds INI parameter is recorded this is treated as a connection loss and a reconnect to the OPC server is initiated Reconnects are done in the cycle of OPCReconnectDelay seconds A special case is the observation of the OPEN PCS7 OPC Server using HDA To be able to recognize a connection loss between the PCS7 server and the OPEN PCS7 server within the interface software and to switch it to HDA mode the OPCDATestltem must be defined Because of the variable RM_MASTER exists in all redundant PCS7 systems the following settings are recommended OPCDATestltem RM_Master OPCConnectionTestTime 30 OPCReconnectionDelay 15 OPCTestitemTSTimeout 0 mandatory The variable RM_Master changes very seldom and provides no new time stamp most of the times when read The value 0 for the paramete
39. d for DA only and the DA notification is not successful Normally this is because of the ItemID is not available in the OPC server Error C_DAError4HDADATags Number of tags configured for HDA DA and the DA notification is not successful Normally this is because of the ItemID is not available in the OPC server Error C_HDAError Number of tags configured for HDA DA and the HDA notification is not successful Normally this is because of the ItemID is not available in the OPC HDA server TC_HDA_InWork The value of this performace counter firstly is the same as the TC_DA_HDA_Tags after successful OPC connection means all errorless configured HDA tags During runtime the value runs down to zero As long as it is not zero the RecoveryStateTag shows the value 1 OPC connection active HDA active at the time When the HDA access is finished the RecoveryStateTag changes to 2 OPC connection active HDA finished To determine that all tags configured for HDA have been working correctly the performance tags Error TC_DAError4HDADATags and ErrorTC_HDAError must be checked in addition for the value 0 Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 34 of 47 SIEMENS 5 19 OpenPCS 7 Workaround Running OPEN PCS7 the use of the parameters described in the following may be helpful in some special cases In case of problems with the connection to Open
40. d the PI System is permanently checked by the SIOPC interface and a reconstitution of the connection is established In case of loss of connection to the PCS7 Server data gaps occur In case of breakdown of the connection to the PI System data are completely transmitted after successful reconnection For this activation of the API Node Buffering for the SiOPC interface is required refer to chapter 8 Hints for API Installation and PI Server Configuration 5 2 Connecting to redundant PCS7 OS redundant OPC server Shall the Pl Connect OPC interface be connected to a redundant OPC server pair without using of OpenPCS7 and the handling of the PCS7 redundancy shall be done by the Pl Connect OPC interface this is done by configuring two OPC server connections in the file SIOPC ini refer to chapter 3 5 OPC DA OPC HDA Parameters The behaviour of the interface software connecting to a redundant OPC server is defined as follows Start up mode On start up the interface tries to open a connection to one of the two OPC servers In case this is not successful the interface tries to connect to the second OPC server If this is also not possible alternately the connection is tried to establish with one of the OPC servers until a connection is established successfully Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 22 of 47 SIEMENS Connection breakdown during runtime After a successful start up the interf
41. e perform the steps described in chapter 3 2 1 Creating a licence Copy the files UMIL_nnnnnn dat and UMIL_nnnnnn txt into the installation path The files are only valid for the computer for which they have been ordered Emergency function In case of a damage of the hardware the interface software can be installed on another PC To run the interface on another PC the software contains the following emergency function Duration is limited to 14 days After this time span the software terminates Within this time span the software can be used without restrictions This function is also possible for the initial run of the software To use the emergency function the existing licenses have to be installed Otherwise the delivered general licenses can be used for the emergency functionality Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 13 of 47 SIEMENS 3 3 General settings Within the group of general parameters those settings are located which are not explicitly assigned to the coupling to the PI System or to the coupling to OPC Type Parameter Explanation ObZ Logfile C OPC_IF_01 log Logfile for output of trace lines should be different for each instance Op FileSize 10000 Maximum size of the log files in Bytes The file is renamed in old when this size is reached Thereby is assured to have a maximum of two files on the hard disc with the stated size OpZ PrintLevel 5 Trace le
42. e to stay in HDA mode Range 1 65535 Recommended 1000 Op HDADelay 700 Time in ms to wait for the next data block via the HDA OPC server Higher values will decrease the load on the PCS7 server Range 0 65535 Recommended 100 Op OPCStringMode 0 Mode used to read or write PI String tags from the OPC Server 0 Normal mode default String is written as VT_BSTR respectively OPC value is transformed to VT_BSTR before further processing 1 read and write string as ByteArray from to OPC Interpretation as 8 Bit character String 2 like 1 but interpretation as 16 Bit character String 3 request a OPC Item as VT_BSTR otherwise always VT_EMPTY Op WindowRecover 0 If WindowRecover is set to 1 the interface works in HDA Window Recovery mode Please refer to chapter 5 12 HDA Window Recovery Mode Op WindowRecoverStartTime Start time of HDA Window Recovery mode Refer to chapter 5 12 HDA 2006 01 25 16 17 54 Window Recovery Mod Format is mandatory YYYY MM DD hh mm ss Op WindowRecoverEndTime End time of HDA Window Recovery mode s Refer to chapter 5 12 HDA 2006 01 25 22 17 54 Window Recovery Mod Format is mandatory JJJJ MM DD HH MM SS Op OPCWriteProtection 1 1 Write protection activated OPC variables can not be written into the OPC Server 0 Write protection deactivated OPC variables may be read and written V3 8a August 4th 201 Page 16 of 47 SIEMENS Op OPCS7WAMaxReadds 3 OpenPCS7WorkAround Number
43. eeeeeeeeeeeeeeeeeeeeeseeeeneeeeeeeeeeeeeneee 38 6 6 Location2 Attribute Scaling on off 02 0 0 ccceeeeeeeeeeeeeeneeeeeeeeeeeteeeeteeeeeeeeeeeeeteees 38 6 7 Locations Attribute lO Ty Pe sissies ccs codastcs Sais cies aane aa 38 6 8 Location4 Attribute Scan Class c cccccceeeeeeeeeeeeneeeeeeeeeeeeeeeeaeeeeeeeeeeeteees 38 6 9 Location5 Attribute PCS7 WinCC Archive cccceeeeeeeeeeeeeeeeeeeeeeeeteees 38 6 10 InstrumentTag Attribute name of the archive variable ssseeeeeeees 39 6 11 Userlnt1 Number of replacement table ccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 39 6 12 Userreali scaling factor cartel ek ie nee ne a A i etn 39 6 13 Userreal2 scaling OSCE seco ae ek cee oleae cee iain cane aeweneee 39 6 14 SourceTag AMMOULGS Siccascsstoesscreecratetueesceieeeceeeeanseece ieee ee eee 39 7 Hints on PCS7 WinCC and the WinCC OPC Servers DA and HDA ee 40 Holy GGUGR Als nico asks iin ilk LO Aen RG hs An tae liaise Th MAES oie TA RS tn 2 40 7 2 Access to the OPC Server Remote access via DCOM cc cceecceeeeeeeeeeeees 40 7 3 Identification of the WinCC Process value archives ceceeeeeeeeeeeeeteeee 41 T PCS 7 Delia LOAGING ciciricttectetscletetisceelaitieug etdiiatteteieielais tute ietel ethics 42 8 Hints for API Installation and PI Server Configuration ccceeeeeeeeeeeeeeteeeeeeeees 43 8 1 Pl interface SDK API Softw
44. eeeeeeeeeeeeeeeeeeeeseeeenaeeeeeeeeeeeeeeee 32 5 13 Logfile limitation eee e cece eeeeeeeeeee eset eeeeeeaaaaaeeeeeeeeeeeeessnaeeeeeeeeeeeeneee 32 5 14 AUlOSIOD FUNCION aaa ede ease tatea te Situs teas Soe ce 32 5 15 Operation on missing of OPC Server call backs seeseeeeeessseesseeeeeeees 33 5 16 Controlling of the OPC connection via an OPC test Item eeeeeeeeeeeees 33 5 17 Option Connection specific Item Prefix SUffIX cee eee eeeeeeteeeeeeeeeeeteee 33 5 18 Performance TAOS ae vavssavs cate ses gees SeasueesGeedc aa E a aaae 34 5 19 OPENPGS 7 Workaro nd irenstean a a coche Sob te 35 6 PIEPomnteontiguratio msaa a A A A A A A A AAAA 36 6 1 Automatic configuration tool option ssssssssssssnnnnresseerrnrnrnnrnsserrnnrnnnnneeeee 36 6 2 Siemens OPC Interface specific attributes nnenseeseesennnnnneeeseeerrrnnnnneeeee 36 6 3 CPONTSOUCE ADUTE a r ela cleat hectic dat athe 36 6 4 ExDesc attribute i ctccta carci tcet ae iivet hdl tembiee dill d ed lietiuhb vids aaded ace beel site 37 Biel IPUIC HNC rac naa la aie tala tA la alah Sra in alien Ste Lat 37 6 4 2 OPC ltemID PCS7 variable Name ccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeteeeees 37 6 4 3 OPC ACCESS Path cvcneteca scat cue a a A a aa aae 37 6 4 4 Bit mask and Shift parameter c cccceeeeeeeeeeeeeeeneeeeeeeeeeeeeeeeeneeeeeeeeeeeeteee 37 6 5 Location Attribute Instance c ccccceeee
45. eeeeeteeeeeeeeeeeeeees 17 3 6 1 Replacement tables for digital conditions DigiCodeTable cee 17 4 Starting and terminating of the Interface 2 0 0 0 cece eee eeeeeeeee cette eeeeeeeeneeeeeeeeeeeeeteeeeeaaees 18 4 1 Starting as Windows console application ceececeeeeeeeeeeeeeeeeeeeeeeeeneeeeeeees 18 4 2 Simplified start as Windows console application by linkages c 18 4 3 Automatic start up as console application after Login eeeeeeeeeeteeeeeeeees 19 4 4 Shutdown of the console application cccccceeeeeeeeeeeeeneeeeeeeeeeeeeeeesnneeeeeeeees 19 4 5 Starting as Windows SOIVICE 2 tscccigisinihipttcctaiettininigietetn dieieighbiniesatdindeigdaige 20 AM General oeei ai eerie ad ite ob ek da bb estes eb ese S hd ate AEGSE 20 4 5 2 Register configure and operation of an Instance as a service 20 4 5 3 Removing service Of an iNStance c cccccceeeeeeeeeeeeeceeeeeeeeeeeeseeenaeeeeeeeeees 21 5 Function of the Siemens OPC Interface cccccccceeeeeeeeeeeneeeeeeeeeeeeeesenneeeeeeeeeees 22 SW COS are aisle has eset sa tat cate aang lace Sue da tae ssa E NEA 22 5 2 Connecting to redundant PCS7 OS redundant OPC server ee 22 5 3 Configuration of acquisition cycles 0 0 eee eee eeeeeeeeee eee eeeeteeeeeeeeeeeeeeeeeeeeees 23 5 4 Special feature on time stamping ccccceeeeeeeeeeeeeeeeeeeeeeeeeteceeeeeeeeeeeeeeeeees
46. ent driven OnDataChange This attribute is mandatory for all PL CONNECT OPC Interface points Hint In the modes 1 to 3 read data transmission between the OPC Server and the interface is done always only on data change This assures a minimized load for the OPC Server and the underlying DC System It depends on the configuration of the group cycles whether the PI API is served cyclically recommended or On Data Change Please refer to chapter 5 3 Configuration of acquisition cycles We strongly recommend to use cyclic supply of the PI API Location4 Attribute Scan Class The number of a scan cycle defined in the file SiOPC_IF ini is stated here If the configured number is not contained in SiOPC_IF ini the point is rejected by the interface This attribute is mandatory for all OPC IF points Location5 Attribute PCS7 WinCC Archive This attribute should only be set for points which will use the archive recovery option Please refer to chapter 5 9 Archive Recovery OPC HDA optional before setting this attribute In the file SiOPC_IF ini the process value archive used by WinCC are listed und numbered serially refer to chapter 3 5 OPC DA OPC HDA Parameter If archive recovery shall be used for a PI point set location5 to the number of the process value archive containing the archive value corresponding with the process variable The name of the archive variable is set in the attribute InstrumentT ag For sy
47. er in the ini file All these parameters are optional The according PI tag is assigned only via the tag name like the IORateTag does Pointsource as well as location1 is not relevant for the interface The pointtype is mandatory Int32 Only the RecoveryStateTag may be of type Digital alternatively Values are written every second on change If the value does not change the values are written every 60 seconds PI Exception test is not performed putsnapshot function Compression is done On startup of the interface the performance tags are set to ScanOn At shutdown they are set to ScanOFF Tag list Parameter name Function RecoveryStateTag Operating state of archive recovery 0 OPC connection not yet active 1 OPC connection active HDA active 2 OPC connection active HDA finished TC_DA_Tags Number of tags configured for DA only TC_DA_HDA_Tags Number of tags configured for DA and HDA Error C_TagConfig Number of tags with errors on the PI configuration determined by the interface E g missing ExDesc HDA tag without entry in the instrumenttag scan cycle not defined etc Faulty DA or HDA names will be recognized with OPC notification and are covered by separate performance tags Info The sum of TC_DA_Tags TC_DA_HDA_Tags ErrorTC_TagConfig is the number of all tags configured for this instance of the interface ErrortC_DAError4DATags Number of tags configure
48. es per second 1 hour in the past 1400 archive values per second These values also depend on the load of the PCS7 server The actual performance is shown in the interface application window during archive recovery Be aware that processing is done separately for each tag Once a tag reaches the actual time this tag is switched to online mode and the archive recovery process starts with the next tag Archive recovery system load Whenever a large data gap gt 1 day is to be filled for a high amount of PI tags gt 100 you may reckon a higher load of the PI server and the PCS7 server particularly when the PCS7 archiving is done in shorter cycles lt 10 sec Please keep in mind The Pl archive must have enough storage space left Example Archive A starts at 01 Apr 2004 04 55 30am At 10 30 00 am the interface is shut down Assumed at this time the archive is filled up to 80 Also assumed ten hours later the archive is filled up to 95 and PI system shifts to the next archive Shortly after the interface is restarted Archive recovery starts with the time range 10 30am to 8 30 pm 10h gap These 10 hours have to be filled into the archive which has 95 of its capacity used If this is a fixed archive an overflow may occur and data will be lost Because of this it is very important to force an archive shift if needed after stopping the interface In case of a very long shutdown it might be useful to force further archive shifts However may be t
49. ever variables of the WinCC OPC server are fully addressed by the ItemID Bit mask and Shift parameter With these parameters single Bits and bit groups may be selected and shifted to the right for better handling For the functionality please refer to chapter 5 6 Bit masking The bit mask is defined with the identifier BITMASK The SHIFT Function is activated with the identifier SHIFT Both parameters are optional The identifier SHIFT remains ineffective without BITMASK Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 37 of 47 SIEMENS 6 5 6 6 6 7 6 8 6 9 Location1 Attribute Instance This attribute defines to which instance of the OPC IF the point shall be assigned Valid values are all numbers from 0 to 9 This attribute is mandatory for all OPC IF points Location2 Attribute Scaling on off Setting this attribute 1 the gathered values are scaled Switching scaling to on requires the attributes UserReal1 and UserReal2 to be set For the functionality please refer to chapter 5 7 Scaling Location3 Attribute lO Type By this attribute the O Type of the point is defined The following values are allowed e 1 read time stamp provided by the OPC server with check and eventually correction recommended e 2 read time stamp provided by the OPC server without check and correction e 3 read time stamp of interface PC e 4 write ev
50. face User manual V3 8a August 4th 201 Page 31 of 47 SIEMENS 5 12 HDA Window Recovery Mode Precondition for HDA Window Recovery si a license for the option Archive Recovery OPC HDA The interface supports 2 modes of HDA Window Recovery Offline Window Recovery is done instead of collecting acutal prozess data The according instance of the interace must be stopped The resulting actual gap in the PI Archive during Window Recovery will be closed by the standard Archive Recovery after the Window Recovery has finished refer to chapter 5 8 In the configuration filef the section fort he according instance must be configured before start of Window Recovery Therfore the parameters Window Recovery 1 and Start and End time must be set refer to chapter 3 5 OPC DA OPC HDA Parameter After restart for all PI tags conifgured for HDA Archive Recovery the values fort he defined time range will be read from the HDA OPC Server and send to the PI Server Thereafter operation stops There is no automatic switch to DA mode No actual values for the tags will be read Pl tags without OPC HDA are not scanned To return to normal operation Windows Recovery mode must be turned off Window Recovery 0 and the interface instance must be restarted Online Window Recovery is done in parallel to the scanning of actual process data In the configuration file the according section fort he instance must be duplicated Therefore the instance number
51. has to be heightened for 100 of the running online instance For Excample for the instance 01 additionaly the instance 101 must be defined and used for Window Recovery verwendet werden All paramters of instance 1 must be copied for instance 101 The parameters for Logfile name und Window Recovery of the Instanz 101 mus be adjusted Thereafter the additional instance with the number 101 may be started This instance uses the license and the PI tags location1 of the instance 1 5 13 Logfile limitation The size of the interface logifle is limited to 10 MB Thereafter the actual logfile is renamed like follows XXXXX yyy gt XXXXX_Old yyy An existing fie with the same name will be overwritten 5 14 Autostop Function Using this function the interface software may be shut down by an external application Therefore the interface tries to open the file lt Applicationpath gt stop txt every 10 second If this file is created by another application the interface succeeds This is interpreted as signal to terminate The file is not deleted by the interface For automatic termination the file should be created for about 20 sec and thereafter be deleted by an external application Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 32 of 47 SIEMENS 5 15 Operation on missing of OPC Server call backs The missing of OPC DA Server call backs is reported and optional a reconnect by the interface can be initiate
52. he Interface 4 1 Starting as Windows console application Hint Whenever the archive recovery option of the interface is used make sure that the archive comparison of a redundant PCS7 server pair has been finished completely before starting the interface If this is omitted gaps in the PI point data may appear which can no more be closed by the interface Closing of PCS7 archive comparison is indicated by a corresponding message in the alarm system of PCS7 Start OPC IF as Windows Console application by inserting e g Programme Siemens SiOPC SiIOPCIF lt X gt The command line parameter lt X gt equals the interface s instance number This parameter controls the access to the various sections of the SiOPC_IF ini file The instance number determines to which PCS7 servers a coupling is established Calls may look as follows C Programme Siemens SiOPC SiOPCIF 01 for instance 1 C Programme Siemens SiOPC SiOPCIF 03 for Instance 3 Complete the parameter file SiOPC_IF ini by a section for the new interface instance and edit the required parameters Please notice e Each instance requires a separate license e Instance numbers 01 to 99 are tolerated for normal mode e Instance numbers above 100 are only be used for funktion Online Window Recovery see section 5 12 HDA Window Recovery Mode 4 2 Simplified start as Windows console application by linkages To start several instances it is convenient to be able to start the ins
53. he interface crashed before starting the interface the free amount of archive space should be checked Eventually fixed archives should be transferred to dynamic archives to handle that The PCS7 servers have to be in stable state On a redundant PCS7 Server pair archive recovery should only be done with both servers working and their own archives being synchronized The load on the PCS7 servers should be looked at Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 28 of 47 SIEMENS 5 10 Supported Data Types and their conversion 5 10 1 List of supported Data Types The following PI Data Types are supported 1 Digital Int16 Int32 Float16 Float32 Float64 7 String oa fw DP Not supported is the PI Data Type Blob The following PCS7 Data Types are supported a Binary Variable Unsigned 8 Bit Value Signed 8 Bit Value a o fF Unsigned 16 Bit Value Signed 16 Bit Value Unsigned 32 Bit Value g Signed 32 Bit Value h Float 32 Bit i Float 64 Bit j String 8 Bit Character set k String 16 Bit Character set gt Oo The following PCS7 Data types are not supported Raw data Text reference All structured data types 5 10 2 Data Type Conversion for reading Points PCS7 numeric a to i gt Pl numeric 2 to 6 By converting the numeric PCS7 Types a to i to numeric Pl Types 2 to 6 loss of exactness may appear depending on the destination tag dat
54. ind Furthermore the existing load caused by the PCs7 project without the interface has to be considered Overload of the channel is not automatically shown by the PCS7 server Having data rates over 200 values a second and whenever the distribution on the AG s is unknown it is recommended to activate the data collection step by step and to check the load of the channels with the possibilities of PCS7 servers In addition we point to the PCS7 FAQs of the OPC performance issues 1 5 Option Archive Recovery via OPC HDA The option Archive Recovery of the OPC IF is able to use OPC HDA to close the data gap since the last shutdown on the next start up e g after service works on the interface PC or the network or after the reconnect to the DCS For further information please refer to chapter 5 9 Archive Recovery OPC HDA optional i Due to the needed OPC HDA server in the DCS this option is available with version PCS7 V6 or higher Archive recovery is an optional package The license must comprise the option to enable the use of this functionality Maybe you need in addition for the usage of the OPC HDA server additional licences for the Process Control System 1 6 Licensing A license is necessary for each PI Interface PC Each of these licenses allows connection to a single PCS7 Server pair If a PCS7 process control system consists of more then a single PCS7 OS server pair a license extension is needed for each additional PCS7
55. lled installion descriptition may be found in the related documentation of the PI SDK API of OSlsoft The following points should be followed PI API buffering should be activated Maxsize of the buffer should be set to a sufficient number Possibility for manual configuration In the file pipc dat piclient ini the following entries should exist APIBUFFER BUFFERING 1 This activates PI API Node Buffering In older versions the additional input of MAXFILESIZE 2000000 is needed in order to set the size of the data file to maximal 2GB The account of the PI API Node Buffering Service should be checked in the Windows service manager and adjusted Please take care that the service is set to automatic Current versions request a user account which is the same as the Windows account the user is logged in Please refer to the OSISoft documentation for details of your version We recommend addressing the PI Server via name resolution hosts table or DNS For correct function of the API buffer server it is necessary that both interface and buffer server use the same name for the PI Server und no mixing of name resolution and direct addressing TCP IP address is used By using an high available PI Server HA PI please refer to the hints in chapter 8 4 Running the Interface against a high available PI Server HA PI 8 2 PI User for the PL CONNECT OPC interface To create a PI Trust account in former times Proxy
56. meout in seconds for the OPCDATestltem Refer to chapter 5 16 Controlling of the OPC connection via an OPC test Item Op OPCReconnectDelay Time delay in seconds between two reconnects Op OPCDAIltemBadStateSupressi Delay in seconds for the OPC DA BAD States of an item to be forwarded to on PI Necessary for Matrikon Tunneler because it marks all items as BAD in case of a network connection error before the interface may react The time should be set to twice the time of PCConnectionTestTime default 15 for Matrikon Tunneler In other cases the function should be switched of with the value of 0 default Op LCID LOCALID of the OPC connection Default is 1031 Germany Op Archive_1 Serially numbered list of the process value archives Please refer to chapter local Prozesswertarchiv 6 9 Location5 Attribute PCS7 WinCC Archive and chapter 7 3 Identification of the WinCC Process value archives Op Archive_2 Serially numbered list of the process value archives Please refer to chapter local Prozesswertarchiv2 6 9 Location5 Attribute PCS7 WinCC Archive and chapter 7 3 Identification of the WinCC Process value archives Op HDADataBlock 750 Maximum size of a data block number of archive values to be read in a single request out of the PCS7 archive Thereby the load of the PCS7 server in HDA mode may be controlled Small sized values here and big sized values for HDADelay result in a lower load of the PCS7 server but will extend the tim
57. nnection returns to normal operation and point updates are recognized again Not supported configurations Replication of data using the elder PI Buffer Server service Pl Bufserv of the PI API to multiple autonomous PI Servers or a Collective is not tested and not supported The redundant version of the Interfaces is not released for operation with a PI Collective or to multiple autonomous PI Servers Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 46 of 47 SIEMENS 9 Revision History April 7 2010 Hetterich V1 3 1 V 3 6 7 Synchronizing with German Version Aug 10 2010 Hetterich V1 3 2 V3 7 1 Chapter OPC Test Item enhanced Chapter Performance Tags added Dec 13th 2010 Hetterich V1 3 3 V3 7 4 Interface Name Pl Connect OPC minor corrections Jan 14th 2011 Hetterich V1 3 4 V3 7 4 Pointclass classic added Jan 31th 2011 V1 3 5 V3 7 6 Revision scale function Jul 29th 2011 Hetterich V1 3 6 V3 7 8 Bad State timeout 17th 2011 Hetterich V1 3 7 V3 7 8 Location5 value 1 Sep 2nd 2011 Hetterich V1 3 8 V3 7 8 New License mode Nov 06th 2012 V3 7 10 General revision Nov 12th 2012 V3 7 10 General revision Dec 10th 2012 V3 7b V3 7 10 paging Dec 21th 2012 V3 7 10 General revision pr 30th 2013 Lutter V3 8 V3 8 0 Functional extension HDA Window Recovery Mode concretion configuration acquisition cycles and IO types running the interface as an service Aug
58. of the OS Server Startup type manual look below Recovery restart the service Running in combination with Open PCS7 an autologon must be performed before starting the Open PCS7 OPC Server This has to be configured accordingly The interface software must not be started before the logon Startup of the interface software should be done with a Net Start Command included in a Batch file in the Startup directory Autostart bat echo Startjob for SiOPC Interfaces net start PICONNECT_OPCPlus_Interface_SA nn Configuration 2 remote connection to WinCC OPC Server OS Server User account corresponds to the Windows account of the OS Servers Startup type Automatic Recovery Restart the service Therefore the PC does not need an Autologon The interface may be operated without a logged in user Removing service of an instance If an instance is no more needed the service may be unregistered The instance must be stopped in advance For the first 5 instances a shortcut for unregistering is created in the installation path of the interface software e g C Program Files x86 Siemens PI CONNECT OPCPlus For all further instance the following command line may be used to unregister the service SiOPCIF u nn nn instance number 01 to 99 After unregistering the instance is no more available in the Windows services Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 21 of 47 SIEMENS
59. operate ALL tags wwhich have the PointSource starting with A This attribute is mandatory for OPC tags Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 36 of 47 SIEMENS 6 4 ExDesc attribute 6 4 1 6 4 2 6 4 3 6 4 4 Structure The ExDesc attribute of a PI Point may contain several parameters The parameters are separated by a semicolon lt DENTIFIER1 Parameter1 gt lt IDENTIFIER2 Parameter2 gt lt IDENTIFIER3 Parameter3 gt For these settings upper and lower case has to be taken in account OPC ItemID PCS7 variable name The first parameter always has to be the OPC ItemID The OPC ItemID is the PCS7 respective WinCC variable name The identifier for this parameter is Item alternative ItemID or Tag may be used because of compatibility Variable name has to be entered completely as shown in the list of variables of the data manager This setting defines the connection of the PCS7 variable to the PI tag Examples ExDesc Entries for a PI Tag ItemID F41000 Regler PV_IN ItemID OAA F65101 VEN FB_OPEN ItemID OAA F65101 VEN STATE BITMASK 0x40000 SHIFT 1 This parameter is mandatory for each Point of the OPC IF OPC Access Path This parameter should not be used in combination with a PCS7 WinCC OPC Server This parameter may be added with the identifier Path respectively AccessPath and is transmitted to the OPC server How
60. r OPCTestitemTSTimeout changes the observation mode of the variable OPCDATestltem from on change to on error and allows the interface to switch to HDA mode on connection return 5 17 Option Connection specific Item Prefix Suffix In praxis the following requirement fort he OPC Interface appeared A redundant DCS redundant double has an OPC Server running on a separate PC as OPC interface holding the connection to the systems containing the data of the DCS The redundant data source has normally an identical set of variables The OPC server does not cover redundancy but shows both variable sets To be able to address these separately the OPC server uses a specific prefix and or a suffix The OPC interface may be configured to access such a system In the PI tag configuration only the identical part of the OPC Item name will be configured The connection specific pre and suffix is set in the configuration file separately for the OPC DA HDA Master and Standby connection To be able to switch between master and standby connection the OPC interface it must be able to detect if the systems behind the OPC server are able to deliver data Therefore a so called OPC Testitem refer to the previous chapter must be defined Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 33 of 47 SIEMENS 5 18 Performance Tags It is possible to define several performace tags in the section PI Paramet
61. r information of the installation please refer to chapter 2 Install und Uninstall In this description the functionality of the interface connecting OPC servers like in PCS7 or WinCC is explained Using other DCS systems the user has to interpret parts of this description for his configuration Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 5 of 47 SIEMENS The interface was designed for OPC DA V2 05a and OPC HDA V1 2 OPC servers It is tested with OPC servers of the following systems Siemens PCS7 V7 and V8 via OpenPCS7 Siemens PCS7 V6 x PCS7 V7 x PCS7 V8 via WinCC OPC DA server WinCC Connectivity Pack Siemens WinCC gt V5 1 WinCC V6 x WinCC V7 x Siemens Teleperm M OPC server only DA Siemens Simatic NET OPC only DA Siemens SPPA T2000 Teleperm XP SPPA T3000 different OPC servers of other producers on enquiry For hints of the installation and configuration of the PI SDK PI API please read chapter 8 Hints for API Installation and PI Server Configuration and the referring documentation of OSlsoft LLC 1 2 Exemplary configuration PI CONNECT OPC should be installed on an own PC The interface is able to connect to both servers of a redundant server pair or to a stand alone server Therefore the interface PC is connected by an own LAN card to the terminal bus of PCS7 By another LAN card the connection to the PI server is established For communication wi
62. rverHDA WinCC Op MasterHDAOPCServerHost Computer name of the PC where the MASTER OPC HDA server is installed Serv1 Op SlaveHDAOPCServerHost Computer name of the PC where the SLAVE OPC DA server is installed Serv2 This value only has to be set if a SlaveHDAOPCServer is defined Please refer to chapter 5 2 Connecting to redundant PCS7 OS redundant OPC server Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 15 of 47 SIEMENS Siemens Pl Connect OPC Interface User manual Op MasterOPCDAltemPrefix Definition of OPC DA and OPC HDA Item prefix und suffix using the MasterOPCDAltemSuffix according option Refer to chapter 5 17 Option Connection specific Item SlaveOPCDAltemPrefix i SlaveOPCDAltemSuffix Prefix Suffix MasterOPCHDAltemPrefix MasterOPCHDAItemSuffix SlaveOPCHDAItemPrefix und SlaveOPCHDAItemSuffix Op OPCHDAMaxReauestTime Time span limit in hours for an OPC HDA request If a request is done with a greater time span the request is parted in the according number of partial requests Default is 144 6 days Op OPCDATestltem Item to verify the connection state of the OPC DA server Refer to chapter 5 16 Controlling of the OPC connection via an OPC test Item Op OPCConnectionTestTime Cycle of the OPC connection checks Refer to chapter 5 16 Controlling of the OPC connection via an OPC test Item Op OPCTestltemTSTimeout Ti
63. ses the archive recovery function the according PCS7 variable 4 must be available in a PCS7 process value archive A breach of this condition in a huge amount may cause errors in the interface software The archive variable name must be specified because normally variables in the process value archive are different from the variable names in the DataManager Therefore the intrumenttag attribute of the PI tag is used Furthermore the archive containing the variable must be specified For this the attribute location5 is foreseen Points not using this functionality should be set to 0 For further information please refer to chapter 6 PI Point configuration Archive recovery makes sense only for PCS7 archive variables corresponding with the chronological sequence of the process value In case of having archived only calculated values e g the total of the last ten values archive recovery does not make sense because in the example you only have a value archived which is about tenth the value Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 27 of 47 SIEMENS 5 9 3 5 9 4 Performance Performance of the archive recovery function depends on the starting point The farther the starting point lies in the past the less the performance will be Here is an example of a performance test Starting point Performance 4 days in the past 180 archive values per second 1 day in the past 800 archive valu
64. set Offset of the scaling function For the functionality please refer to chapter 5 7 Scaling The attribute is mandatory for all PI point with the attribute location2 scaling on off set to 1 6 14 SourceTag Attribute Tag name of the source point whose data should be written into the PCS7 variable If the own value shall apply the own tag name must be inserted Refer to chapter 5 5 Writing PI data OnDataChange This attribute is required for all points with the IO type write on OnDataChange Location3 3 This attribute is not used for all other Points of the OPC IF Please take into consideration that the indicated tag must exist in the Point Database of the PI Server Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 39 of 47 SIEMENS 7 Hints on PCS7 WinCC and the WinCC OPC Servers DA and HDA 7 1 General The OPC DA and OPC HDA interfaces are open interfaces defined by the OPC Foundation www opcfoundation org OPC servers provide access to process data for OPC clients Actual values can be read or written via the OPC DA Data Access server OPC HDA Historical Data Access servers enable access to historical process values as to process archive values OPC Clients make use of an OPC DA HDA OPC Server services to read and write process data The Siemens OPC Interface is an OPC client optimised to access the WinCC DA und HDA OPC Server WinCC itself is a core module
65. stant parameter may not be modified Some parameters are only read once when starting others are read cyclic every 30 seconds Listing of all types Type Meaning K Constant parameter Op Optional parameter only read during start up OpZ Optional parameter read cyclically Ob Compulsory parameter only read during start up ObZ Compulsory parameter read cyclically For optional parameter the indicated values in all the tables below are the default values which are used if the parameter is not indicated Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 12 of 47 SIEMENS 3 2 Licence settings 3 2 1 Creating a licence The software is licensed to the machine on which it is running To receive a valid license file proceed as follows Copy the CreateUMI exe and the UMIL dll contained in the delivery package to a directory e g C umi Run the file CreateUMI exe When you see the press any key in the opened window finish the operation by pressing any key A file named UMI_xxxxxx dat will be created where xxxxxx is the name of the PC where you did run the CreateUMI exe Send this file to us e g info rhm industry siemens com You will receive the license files for the requested software To have the license files available for installation it might be useful to do this some time in advance to installation 3 2 2 License Activation 3 2 3 If not already don
66. stems which do not needs a process value archive name prefix in front of the archive variable name e g Siemens T3000 the value 1 has to be set in lacation5 to activate the HDA function This attribute is mandatory for all OPC IF points using archive recovery Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 38 of 47 SIEMENS 6 10 InstrumentTag Attribute name of the archive variable This attribute should only be set points intended to use Archive Recovery If the attribute contains an empty string or no licence for Archive Recovery is found the function is disabled fort his point For the functionality please refer to chapter 5 9 Archive Recovery OPC HDA optional This attribute is mandatory for all OPC IF points using archive recovery 6 11 Userlnt1 Number of replacement table The function replacement table is only disposable for digital PI Points 0 No replacement table OPC process values without transformation into PI system gt 0 Number of replacement table If this function is used it has to be proofed that the replacement table is defined in the configuration file before start up interface or definition of PI Points 6 12 Userreal1 scaling factor Factor of the scaling function For the functionality please refer to chapter 5 7 Scaling The attribute is mandatory for all PI point with the attribute location2 scaling on off set to 1 6 13 Userreal2 scaling off
67. tances via desktop symbols Please proceed as follows e On the Windows desktop for each requested instance create a link referring to the file Programme Siemens SiOPC SiOPCIF exe Use reasonable indications for the connections e g indication of PCS7 server coupling the instance lt PCS7ServerName gt _to_PI e With a right mouse click activate the connection s dialogue Features select table connections and insert the required command line parameter instance number in field target behind SiOPCIF exe e g C Programme Siemens SiOPC SiOPCIF 01 for Instance 1 C Programme Siemens SiOPC SiOPCIF 03 for Instance 3 e Activate the connection s dialogue features select table connections and select option minimized in field execute Complete the parameter file SiOPC_IF ini by a section for the new interface instance and the required parameter Please notice Please notice e Each instance requires a separate license e Instance numbers 01 to 99 are tolerated for normal mode e Instance numbers above 100 are only be used for funktion Online Window Recovery see section 5 12 HDA Window Recovery Mode Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 18 of 47 SIEMENS 4 3 Automatic start up as console application after Login Setting up the automatic start up of the interface software requires three steps 1 Set up of the Windows Auto Login
68. th the PI server the interface software requires the PI API SDK Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 6 of 47 SIEMENS 1 2 1 PCS7 via Open PCS7 For the process control system PCS7 V7 and V8 we recommend the additional interface component OpenPCS7 server installed on the interface PC OpenPCS7 provides the OPC DA HDA servers and hides the redundancy of the PCS7 OS servers OPC HDA is used for the option Archive Recovery of the PI CONNECT OPC interface In this configuration we also recommend the usage of one instance of the interface software for each PCS7 OS server pair among others for the fault recognition OpenPCS7 is not included in the scope of supply of the PIL CONNECT OPC interface See also chapter 5 19 OpenPCS 7 Workaround PI Client PI Client PI Client ProcessBook DataLink PI SMT PI CONNECT OPC Interface PC Ethernet network OSI Soft PI API PI SDK Plant Information System Server V3 4 Siemens Pl Connect OPC Interface Eth k COM DCOM thernet networ Pear to pear connection recommended OpenPCS7 OPC DA HDA OS LAN Terminal bus SIMATIC PCS7 OS SIMATIC PCS7 OS SIMATIC PCS7 OS server server l Ml Redundant Redundant Redundant PROCESS Siemens Pl Connect OPC Interface User manual V3 8a August 4th 201 Page 7 of 47 SIEMENS 1 2 2 PCS7 WinCC via WinCC OPC server For WinCC and PCS7 V6 the PI CONNECT OPC interface is
69. to the next faster cycle All process values having the same cycle are signed up for one group in the OPC server A definite offset for the start of the scan cycle is not adjustable Processing starts in groups with a delay of some seconds after reading the configuration out of the PI server Directly after the start of data collection for a group the process values are read Because of this on start up of the interface the first values for all cyclic reading points will appear in the PI system after a short time An optimisation algorithm assures to un register no more needed process values caused by a PI Point update DELETE However on very large changes in configuration we recommend the interface be restarted 5 4 Special feature on time stamping The Pl Connect OPC Interface works in the face of the OPC Server of the DCS in a way to generate a minimum of load on the DCS Thus only value changes are transmitted from the OPC server to the Pl Connect OPC Interface If a value is constant for several reading cycles no new value will be transmitted to the interface If only these changed values are provided to the PI API reproducing problems would appear in the PI archive Especially values running for a long time constantly with a sudden jump appearing will not be shown as a jump but as a ramp left picture 5 5 5 5 5 5 4 5 4 5 4 4 3 5 3 5 3 3 2 5 2 5 2 10 15 00 10
70. trnnnnrreeerrrrnnnnn 10 1 5 Option Archive Recovery via OPC HDA cccccceeeeeeeeeeeeeeeeeeeeeeeeetneeeeeees 10 6 EicensiMgasan om A Ae ote So AE N E EAA 10 2alnstall und Uninstall assises ea a a aa a eee erecce 11 2 1 Requirements for the Installation cccceeeeeeeeseeeeeceeeeeeeeeeeseeeeeeeeeeeeeeeeeees 11 2 2 Installation of the Interface Software ccceeceeeeeeneeeeeeeeeeeeeeeeeneeeeeeeeeeeeeees 11 e256 Femme 191 gt ee ORE PE rent eae MORE Pen ncn e ERR TRE U RA a EL ORs RAE A 11 3 Configuratio anasepa ise toee tones degheead one nctes deptakan E A eter aes ae 12 3 1 Structure of the tile SIOPG IF AN xc2cccccsccsteticialcisigceloedintalaldinialaieioiaeledeieleiee 12 3 2 Licence SCTINGS fei crccdace inciaitetacats etek he latlpied dike icetd eb cetiieitsitdteldadteeente dats 13 3 2 Creating a ICCNCe sak aa aaa sal ae ia A esti in teal loth in el Rots 13 3 2 2 LIGCNSOACIV ANON eres tats octieds tend cece cues A iudecnen e A AE AEA 13 32210 Emergen y functo N a te scee a A AE oka shat tet aa D Ekaa 13 3 3 General settings neeeeeeeoeeeeeneeeeeeeeertttrnttteeerrtttrnnnttseettttttnnnntneeertntnnn nenene 14 3 4 PI System ParametelS ccccccccceceeeeeeeeeceeeeeeeeeeeeeeeeeaeeeeeeeeeeeeeeeneeeeeeeeeeeeeeeee 15 3 5 OPC DA OPC HDA Parameters cccccccceeeeeeeeececeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 15 3 6 Global Parameters for all instances valid ccceeeeeeeee
71. vel for output on the screen major error error warning status variation Point updates summary Point update for each point gt 7 only for DEBUG purpose N O T for normal use GP IE OD OpZ LogLevel 5 Trace level for output in the log file Meaning similar to PrintLevel Cycle_1 1000 1 1 Scan cycle 1 for cyclic reading of values refresh flag DataChange Flag refer to section 5 3 Configuration of acquisition cycles Cycle_2 1000 1 1 Scan cycle 2 for cyclic reading of values refresh flag DataChange Flag refer to section 5 3 Configuration of acquisition cycles and so on OpZ BufferLimit 100000 Maximum amount number of process values of the internal buffer between OPC and PI Interface Range 1000 1000000 recommended 100000 Op ValueState_Bad 255 PI Point state written if the OPC Variable has set the Quality Flag meaning Bad Range 1024 0 alle PI States default 255 BAD INPUT Op ValueState_Uncertain 0 PI Pointstatus written if the OPC Variable has set the Quality Flag meaning uncertain Range 1024 0 all PI States default 0 OK resp no State Itis possible to define 30 different intervals for the cyclic reading of values The intervals must be defined completely It is not possible to define interval_1 to interval_5 and interval_7 without prior definition of interval_6 At run time no intervals may be deleted or modified Nevertheless
72. ycel_3 1000 optionally 1 0 Cycel_4 2000 optionally 1 0 Cycel_5 5000 optionally 1 0 Cycel_6 10000 optionally 1 0 Cycel_7 60000 optionally 1 0 Cycel_8 300000 optionally 1 0 Cycel_9 600000 optionally 1 0 Cycel_10 3600000 optionally 1 0 Cycel_11 2000 optionally 1 0 Cycel_12 z 3000 optionally 1 0 Cycel_13 4000 optionally 1 0 Cycel_14 5000 optionally 1 0 Cycel_15 10000 optionally 1 0 Cycle times are in milliseconds Thereafter the switches for the kind of data communication between the OPC server and the PI CONNECT OPC Interface may follow comma separated The first switch sets the cyclic refresh to on second one sets the DataChange notice When DataChange is activated 1 all actual changes of the process values will be written in the internal cache and also directly forwarded to the PI API When Refresh is activated 1 the interface tests cyclically the cache and forwards the last received value to the PI API Those PI tags who are configured for a cycle that is activated for Refresh in each case the IO Type 1 or 3 should be used refer also section 6 7 Location3 Attribute IO Type and 5 4 Special feature on time stamping For optimal mode of operation both switches Refresh and DataChange should be set to 1 This is also the default value if those switches are not present In this case the interface forwards