Home

User manual Ultrasonics Generator soniKKs digital K1-Z

image

Contents

1. Attention hot surface Do not Touch Possible damage without danger for people Electrical voltage Symbols on device CE Conformity Symbol 2 Conventional use The generator was designed to be used for die grinding applications Just operate with the generator when accessories from soniKKs are mounted such as transducer sonotrode and sieve If you use the generator with other components no functioning guarantee is furnished For other applications please obtain explicit written approval from the producer 2013 04 06 sonikKKs GmbH Ultrasonics Technology Doc nr 3000 23012Z C page 4 of 16 SONIKKS a 3 Security instructions gt Operations of all ultrasonic equipment by trained staff only gt Do not use this unit in explosive environments without taking all necessary security measures gt Check the unit any time before operating gt The electromagnetic compatibility conforms to international standards For more details consult the Technical data section of this manual gt All necessary adjustments are either made by the manufacturer or are described in this manual In case of any trouble with the generator do contact our technical service gt Never open the unit or in any way tamper with it This will void your warranty and may cause an electric shock gt For any cleaning or maintenance of the device please disconnect the mains supply gt All maintenance should be done b
2. ULTRASONICS TECHNOLOGY 2013 04 06 N i GmbH SONIKKS ULTRASONICS TECHNOLOGY soniKKs GmbH Ultrasonics Technology Doc nr 3000 23012Z C page 1 of 16 GW kke ULTRASONICS TECHNOLOGY Table of contents MOU CIO sou ipa sare tatattoarcariarcarntourtadies aad E E E 3 Se Neral I Ora Olt aa E uuniiedhasanaaanetihweunmleatnaneiie E 3 SOY ATE E EE E AE EN EE E A uid snes E N EE E E E E S 4 E COMVEMMON AI USE ae E E A E E A E 4 Ze O CUNY IM rC O a E 5 DEAC PIO MONE aaee E E E 6 PECCI CONN S O aa E RE E EE E EE 7 MSC IMAC Dal deea E E E E 7 Connections on the backside Of the generator ccsecsecseccecceccecceccecceccecceececceeceeceeceeceeceeseeceeseeseesetsetsees 8 E Menapa E E enate oa ceaeaia vane E 9 2 Inteface signal description wasincinnteccunesieescnactncnmensassunaebacngradtnesnadsacsunanieshenaatn cam ataasunaeiacnoneeins 11 Controls and display elements estes siete cao niensauatustoaetueunnneuasunus wore aina NAA AA AEEA NE KNEE 12 k WED Slats n OE e E E E S 12 Ze OOO atasceemntscecunaradanianensnssachanasegursduacgatsntcuncaa dean aatseimudut ate sunarasaccuiiesnssambanaiugenatsaupelsaecensnadanean 12 TOUDI SNOOT arsane r Ar EEEE E E T E cocatieeeounviesecetannace 13 Manen e and e l E ar T E E EA EEEE E En 14 Wa EE EEE EEEE E EEES 14 Declaration of CONMPOrMILY ccccecsecsecseeeeeeeeeeeeeeeeseeeeeeeeeeeeeeeeeeeeeeeseeeeeeeeeeeneeseeseeeeeeeeeeeeeesarsensenseenengags 15 MPANA E E S 16 2013 04 06
3. N The generator may only be connected to a proper mains supply The allowed voltage is 230 Volt AC 50 60Hz eizspannung 210 250 V AC Linevoltage LtN PE 50 60 Hz Max 600 Watt 850 VA l Dauerleistung continuous power The mains supply must have a protective earth oo connection Care must be taken that the supply connection carries neither over nor undervoltage this may cause malfunction or even damage the unit Technical Data 260 x 85 x 200 mm approx 2 kg IP 20 IEC 60 529 EN 60 525 Depending on generator type 20 100 kHz 210 250 VAC 50 60Hz Depending on model up to 4 A Maximum 800 w 10 C through 40 C not condensing 2013 04 06 sonikKKs GmbH Ultrasonics Technology Doc nr 3000 23012Z C page 7 of 16 K soniKKs Connections on the backside of the generator i i mene e Before opening A Amst d oor we Interface ret Connections Transducer connector HF output Interface connector Mains switch Mains supply VV VV ATTENTION When connecting a converter an additional protective earth connection must be provided This cable must provide a sufficient cross section of at least 1 5mm2 2013 04 06 soniKKs GmbH Ultrasonics Technology Doc nr 3000 2301Z C page 8 of 16 SoOniKKS ULTRASONICS TECHNOLOGY 1 Interface pin out ling j Common relay root for HF DA and ERROR relays GND Common ground FS ND Remote input ac
4. gt Malfunction of the cable to the transducer short circuit How to fix the problem 1 Disconnect the cable to the transducer 2 Switch on the generator with the test button Then what a The error still comes up generator faulty b The error does not come up again transducer or cable faulty The Error LED comes up with some delay after the generator is started with the test button Possible reasons gt There is no ultrasonic converter connected gt The tool has a malfunction gt The ultrasonic converter is broken gt Malfunction of the connection cable or plug How to fix the problem 1 Check the transducer converter and sonotrode exchange them if necessary 2 Check cabling and connectors exchange them if necessary Overtemp LED lights up or flashes If the generator gets overheated during sonification the Overtemp LED will light up and the generator switches off automatically When cooling down below the trip point the generator restarts automatically The Overtemp LED will flash to signalize this error until the generator is switched off with the test button or the remote control Possible reasons gt The cooling slots are obstructed gt Device is placed too close to another heat source gt Malfunction in the converter gt Malfunction of the fan How to fix the problem 1 Check the fan 2 Check the cooling slots on the backside of the generator 3 Check device placement
5. C power line Unauthorized modification of the device makes this declaration void Dobel 01 11 2008 Klaus Kern Managing Director 2013 04 06 soniKKs GmbH Ultrasonics Technology Doc nr 3000 23012Z C page 15 of 16 WG kke Imprint Purpose and use The operating instructions explain the construction and operation of the ultrasonic generator soniKKs K1 Z in connection with standard accessories for use in laboratories and the industry Please read especially the safety instructions carefully and observe them all time The operating instructions should always be at hand to help you to solve any questions and problems that may arise All rights reserved The manual has been prepared with all due care nevertheless faults and omissions cannot be fully precluded sonikKKs GmbH reserves the right to make changes to the technical data and specifications during the curse of further development of the product Without given prior notice The warranty does not cover any malfunctions injuries and damages that result from such use or improper operation in use Address Editing soniKKs Ultrasonics Technology GmbH first edition August 2012 Neuenburgerstrabe 72 75335 Dobel Germany Phone 49 0 7083 92 48 360 Fax 49 0 7083 92 48 370 Mail info sonikks de www sonikks de www sonikks com 2013 04 06 sonikKKs GmbH Ultrasonics Technology Doc nr 3000 23012Z C page 16 of 16
6. and an ultrasonic signal is available on the output socket 5 Error relay This pin is internally connected to the error relay contact root of the relay contact is pin 1 Normally open If there is any malfunction of the generator this relay contact will be closed 6 Not used in this version 7 P Out On this pin there is a voltage proportional to the emitted ultrasonic power in the range of 0 10 volts This voltage corresponds to the nominal ultrasonic output power OV 0 10V 100 8 15V This output provides an auxiliary voltage of 15V for external use The maximum output current is 100mA 75mA permanent load and can be used as a supply voltage of the relay root HF DA amp Error on pin 1 2013 04 06 sonikKKs GmbH Ultrasonics Technology Doc nr 3000 23012Z C page 11 of 16 C sonikKKs ULTRASONICS TECHNOLOGY Controls and display elements 1 LED status indicators Indicates that the generator is connected to the mains supply and the mains switch is switched on Error Indicates that there is a malfunction Overtennp 2 Controls Test Button Potentiometer power For the adjustment of the ultrasonic power 2013 04 06 sonikKKs GmbH Ultrasonics Technology Doc nr 3000 23012Z C page 12 of 16 Troubleshooting The Error LED comes up right after the generator is started with the test button Possible reasons gt Malfunction of the ultrasonic converter
7. he ground If the unit shows significant differences from normal operation VV VV WV Device Placement A running generator can heat up noticeably If the generator cannot dissipate the heat there is a possibility of an overheat condition An error message Overtemperature will appear if a display is connected and the OVERTEMP LED will light up See the error description Overtemperature for details If possible avoid operating the unit at ambient temperatures above 30 C 86 F Make sure that sufficient cool air can reach the generator for proper cooling Air conditioning helps in high temperature environment Always keep the cooling slots on the rear of the generator clear Do not place anything in front of the cooling slots Avoid heat sources close to the generator to avoid overheating Also avoid direct sunlight exposure Place the unit so that no humidity or fluid can come into the generator Lay the cables in a way that no one can stand on them or stumble over it Never carry the device holding it on the cable ATTENTION Place the unit in a way that no vapor water or other can get into the device Dusty or chemically contaminated air may cause long term corrosion of the device Avoid heat sources close to the generator to prevent overheating 2013 04 06 soniKKs GmbH Ultrasonics Technology Doc nr 3000 2301Z C page 6 of 16 sSonikKKsS ULTRASONICS TECHNOLOGY Electrical connection
8. pay attention at the placement advice 2013 04 06 sonikKKs GmbH Ultrasonics Technology Doc nr 3000 23012Z C page 13 of 16 GW kke Maintenance and care There is no need for special maintenance Please remove any dust and dirt with a damp woven fabric Do not use any chemicals to clean the generator Keep the cooling slots clear at all times Warranty The period and extent of the warranty is part of the commercial terms and conditions Special agreements are part of the confirmation of the order Warranty exclusion applies in the following cases Damage due to wrong handling or tampering Damage due to wrong application Damage due to shock dirt or moisture Damage due to operation by nonqualified staff Damage due to nonobservance of safety regulations or accident prevention regulations Damage due to modifications to the operating manual VV VV VV 2013 04 06 soniKKs GmbH Ultrasonics Technology Doc nr 3000 23012Z C page 14 of 16 GW kke a Declaration of Conformity We sonikKs Ultrasonics Technology GmbH declare in sole responsibility that the product Type Ultrasonic generator soniKKs digital K1 Z xxxx xxxx symbolizes the different power ratings Correspond to the following EEC directives EN 50081 1 EN 50082 2 EN 55022 EN 55014 EN 6055 EN 61000 The requirements of the low voltage directive are observed ATTENTION The device is not designed to be connected to the public utility A
9. soniKKs GmbH Ultrasonics Technology Doc nr 3000 2301Z C page 2 of 16 SONIKKS a Introduction Dear customer we would like to thank you for buying this product You have purchased a high quality product developed based on the latest technology standards developed and produced exclusively in Germany For your own safety please read this manual carefully before using this product and keep this manual in a place where it is accessible for all users ATTENTION Make sure that all electrical connections are only made by trained staff Only qualified service personnel may open or modify the device General information The ultrasonic generator soniKKs digital K1 Z is a device which is used normally for ultrasonic die grinding applications The main features are Autotuning circuit to tune automatically to the resonant frequency of the connected horn Fully digital frequency generation High speed microcontroller to control all functions of the generator Potentiometer for the adjustment of ultrasonic power Vv Vv Vv V WV Protected against a short circuit b idle run c overtemperature d overload 2013 04 06 soniKKs GmbH Ultrasonics Technology Doc nr 3000 23012Z C page 3 of 16 WG kke ULTRASONICS TECHNOLOGY Safety Below you can see all the warning and security symbols used in this manual Symbols in manual Immediate imminent danger health and live bad injuries or dead
10. tive low link to ground to turn on the generator Optionally also remote with 24 V is available HF DA relay Relay output HF DA closed when ultrasonic voltage is emitted Error relay Relay output Error closes upon error Normally open Not used in this version P out Output 0 10 Volt corresponds to the output power 0 100 15V 15 Volt supply voltage for external use max 100mA 2013 04 06 sonikKKs GmbH Ultrasonics Technology Doc nr 3000 2301Z C page 9 of 16 SONIKKS aam Connection description Generator 8 pole Interface HF Error DA Relais Relais Example of external connections f 2013 04 06 soniKKs GmbH Ultrasonics Technology Doc nr 3000 2301Z C page 10 of 16 WG kke a 2 Interface signal description 1 HF DA amp Error Common input output root of the internal relays HF DA and ERROR Relay input output signals have no reference to GND 2 GND Common reference point for input output signals except for the relay outputs 3 FS GND To switch the generator on connect this signal to GND pin 2 4 HF DA relay As soon as ultrasonic voltage is available on the HF output socket a relay contact closes and this pin 4 is linked via the relay to Pin 1 HF DA amp ERROR Normally open To use this function connect for instance 24V to pin 1 HF DA amp ERROR This voltage will then appear on this pin 4 as soon as the generator is turned on
11. y trained staff only gt Please pay attention at all warnings and hints in this manual and on the generator gt Take care of the mains supply voltage Over or undervoltage can cause malfunction or destroy the generator gt Always place the generator on a stable and flat surface gt Correct operations can only be guaranteed if the generator is used along with the recommended ultrasonic transducers gt Use only the recommended interface cables Do not coil up the RF cable or the line cord Coiling up these cables can cause overheating of the cables gt While using the generator with sonotrodes do not touch horn and sonotrode Caution could be very hot gt Never focus the connected transducer at people gt If you work with sonotrodes please wear an adequate ear protection or just operate in an acoustic noise protection box gt Please avoid the operation of the generator in presence of animals They have a more extended frequency range of audible sound than people ATTENTION Continuous operation will lead to hot surfaces of the horn and the Sonotrode They can heat up to 100 C 2013 04 06 soniKKs GmbH Ultrasonics Technology Doc nr 3000 23012Z C page 5 of 16 SONIKKS a In the following cases immediately disconnect the unit from mains and call a qualified service technician If cables or connectors are damaged If the housing is damaged If fluid came into the generator If the unit fell to t

Download Pdf Manuals

image

Related Search

Related Contents

Read this entire manual before operating.  Accounts Receivable User Manual Dim3D  Samsung GT-P5210 Benutzerhandbuch  Samson AirLine Micro AL2 Wireless Camera System Manual  EQUIPOS DE ALIMENTACIÓN DE CORRIENTE CONSTANTE  Good Morning Cardin - Cardin Elettronica  PIMAG® SPORT BOTTLE / BOUTEILLE PIMAGMD    