Home
        PDF-VORLAGE USER MANUAL
         Contents
1.    mE AQ    User manual  lenos    light    Art Nr  111 350       30   Mattress turning system       Health  Safety  Independence          me A    List   List of contents   contents    1 Foreword   2 Safety instructions   3 System installation and setting up lenos   light  4 Installation   5 CPR   6 Setting cycle times   7 Setting the angle   8 Technical data    9 Indication       Page 3    Page 4  Page 4  Page 5  Page 5  Page 6  Page 6  Page 7    Page 7       2    User manual lenos   light   Version 06 2006 IH       a Aca    Dear client        The lenos   light system is a turning system for Pressure Ulcer prevention and  treatment produced by ADL GmbH Germany     The lenos   light system is developed to be used in combination with Pressure  Ulcer prevention and treatment mattresses    With continuous inflating and deflating of both aircushions the patients lying  position is changing to an angle up to 30      The previously strongly pressured skin area is relieved and the pressure will be  distributed over a larger surface    For patients with pressure ulcers on their back it is possible to leave out the  back position to relieve pressure ulcers in that area        Pressure relief of the patients side is not possible with lenos   light     Before using the lenos   light system  please carefully read this user manual        We hope you find this guide a straightforward and helpful aid to using the  system  Should you have any questions  please contact your supplier for furthe
2.   J Check after each first full cycle if the proper angle is reached     When the patient cannot endure the automatic positioning  e g  is panicking   the treatment should be stopped        User manual lenos   light   Version 06 2006 IH       a Ace      8 Technical data     8 Technical data   data       Description lenos   mattress lenos   power unit  Material Polyurethane     Dimensions in cm  L x B x H  200 x 100 x 25 31x 12x 26  Warranty 2 years 2 years  Electr  connections    230 V   50   60 Hz  Fuse    230 V  2 0 A  Cleaning 60  C chemo thermal washing disinfection    disinfection possible       We advice a cleaning process approved by the Robert Koch institute    9 Indication    Please always keep the service manual with the system   Untroubled operation of the system only can be ensured if regular service  inspection has been carried out     For technical problems you turn please to your contract dealer  or directly to e ADL   GmbH         Dealer stamp                 User manual lenos   light   Version 06 2006 IH       er    ADL    Medical B V  International  Edisonstraat 6   5051 DS Goirle   The Netherlands   Phone   31 13 5772 088  Fax    31 13 5772 648  E Mail  info adlmedical nl  Internet  www adlmedical nl       ADL   GmbH  Lise Meitner Strasse 3   48161 Muenster   Germany   Telephone    49  2534  622 4 0  Telefax   49  2534  642 70    ADL   GmbH   Production   and service centre Erfurt   Thoereyer Strasse 1   99334 Ichtershausen   Germany   Telephone    49  0 3 
3. 62 02 75 19 0  Telefax    49  0 3 62 02 75 19 12    E Mail   info adl gmbh de  Internet  www adl gmbh de       QUALIT  TS   MANAGEMENT  Wir sind zertifiziert      Regelm    ige freiwillige N 72    berwachung nach EN 15013485 SS Yeo  RTER cee              QUALITATS   MANAGEMENT  Wir sind zertifiziert    Regelm    ige freiwillige N    berwachung nach 1509001 2000        Copyright by    ADL GmbH   Muenster    Date 06 2006       User manual lenos   light   Version 06 2006 IH    
4. etween bottom the bed    amp  Fix the aircushions to the upper mattress in use with the fixation straps        Connect the tubes to the power unit and plug the power supply in     When using a foam mattress a special cover is needed for proper fixation    to the bottom        4 Installation       Switch on the power unit with the green button     The green light is illuminated to indicate the power unit is powering up      Select the required function        Each time after switching the power unit on  the aircushion are deflated  on maximum capacity     For quickly deflating the system  please disconnect the tubes from the power unit        User manual lenos   light   Version 06 2006 IH    mu Aa    6   6 Setting cycle times   cycle   6 Setting cycle times         You can adjust cycle times between intervals of 60 minutes up to maximum 120  minutes  This can be done by operating switch   of the power unit     You have two ways of changing the patient s position  Right   Back   Left or    Right   Left by leaving out the back position   You can select the desired way of positioning by operating switch    of the power    o ea       light  30   Lagerungssystem  Zykluszeit R  cken 30   Lagerung  120 Min  ohne  g E 1    60 Min     as Anti Dekubitus Produkte    7 Setting the angle    With the turning knob  amp   30   Lagerung  you can adjust the position angle   The set angle will be reached within a certain range depending on the mattress  used and the body weight of the patient   
5. r  direction and assistance     Your    ALE om       User manual lenos   light   Version 06 2006 IH       a Ace      2 Safety instructions     2 Safety instructions   instructions    Warning  The compressor is under pressure as soon as the power supply is plugged  in  Before opening the housing of the compressor the power lead must be un   plugged  Repairs must only be performed by qualified personnel    The compressor must only be used for its intended purpose     Check if tubes are not bent or trapped between other parts     Perform an hourly check en at least after each positioning cycle on the patient s  position     Do not use any aggressive cleaning detergents   Do not enter combustible gasses or liquids into the system     Without a suitable mattress  proper use of the lenos   light system is not possible     3 System installation and setting up lenos   light       Parts list   Item No      Quantity Description Item No   1 Module lenos light 111 303   Two connected aircushions   1 Power unit incl  power cord 111 351  1 Service Manual 999 190  1 User manual 112 009 GB    Components  not necessarily part of the shipment      Quantity Description Item No   1 Cover 111 305  For fixation of foam mattresses       4    User manual lenos   light   Version 06 2006 IH       na Acs      Position the aircushions on the base of the bed frame and fix the straps to the  bed  to the    up and down  moving parts of the bed          amp  Put the tubes through the space at the foot end b
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
TTI Motor Vehicle Operations Program  FY-15ZB3 の取扱説明書  GARANTIA SEARS DIAGRAMA DEL CORTACERCO  guida di buona prassi igienica per i caseifici di azienda agricola  Autostart AS-PRG-1000 User's Manual    Manual de instrucciones  Hafler IRIS Stereo Amplifier User Manual  Gebrauchsanleitung User manual Mode d'emploi  Samsung Galaxy A3 دليل المستخدم(Kitkat)    Copyright © All rights reserved. 
   Failed to retrieve file