Home
JDSU: User Manual - SmartClass™ Fiber FBP-HD4i
Contents
1. MORE Access additional OPM options as follows EDIT WAVELENGTH TABLE REVIEW OPM DATA ENABLE WATTS DISPLAY ENABLE OPM IMAGE LINK SYSTEM SETTINGS USER INFO MORE dB dBm Switches between Absolute dBm and Relative dB power level unit For further information on Absolute and Relative Power see the Measuring Optical Power section on page 47 NOTE The device can also display values in Watts To activate this option check ENABLE WATTS DISPLAY in the MORE menu SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P 43 CHAPTER 6 44 SmartClass Fiber FBP HD4i HD4iP amp OLP 82 82P SET REF Stores a reference power level NOTE This is used when measuring attenuation relative power For further information on measuring Relative Power see the Measuring Optical Power section on page 47 A WAVELENGTH Selects the desired active wavelength for testing NOTE The wavelength values that appear in this list is managed in the EDIT WAVELENGTH TABLE under MORE see next section for details MORE Access additional OPM options as follows e EDIT WAVELENGTH TABLE Feral Edit OPM Wavelengths i A REF 1 0 0 0 1 5 Upon selection a list of all the wavelengths will appear as shown above Each wavelength in this list will include the following Checkbox gt Located on the left side Checked items will appear on the wA WAVELENGTH J list on the main OPM screen Press th
2. SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P Inspect test certify and save with one device USER MANUAL 22002224 REV 0 Notice Copyright Trademarks FCC Information European Union Independent Laboratory Testing Every effort was made to ensure that the information in this document was accurate at the time of printing However information is subject to change without notice and JDSU reserves the right to provide an addendum to this document with information not available at the time that this document was created Copyright 2012 JDSU LLC All rights reserved JDSU Enabling Broadband and Optical Innovation and its logo are trademarks of JDSU LLC All other trademarks and registered trademarks are the property of their respective owners No part of this guide may be reproduced or transmitted electronically or otherwise without written permission of the publisher JDSU is a trademark of JDSU in the United States and other countries Electronic test equipment is exempt from Part 15 compliance FCC in the United States Electronic test equipment is subject to the EMC Directive in the European Union The EN61326 standard prescribes both emission and immunity requirements for laboratory measurement and control equipment This unit has been tested and found to comply with the limits for a Class A digital device This unit has undergone extensive testing according to the European Union Directive and S
3. 8X AA 10 USER MANUAL Getting Started CHAPTER 3 Additional Items in Basic Kits e P5000i Digital Inspection Microscope e Inspection Tips and Adapters Bulkhead SC and LC Patch Cord 2 5 and 1 25 mm e 1 25 mm OPM Adapter OLP 82 82P only Additional Items in Pro Kits e P5000i Digital Inspection Microscope e Inspection Tips and Adapters Bulkhead SC and LC Patch Cord 2 5 and 1 25 mm e 1 25 mm OPM Adapter OLP 82 82P only e Cleaning Materials for 2 5 and 1 25 mm Bulkhead and Patch Cord e FFL 050 Visual Fault Locator with 2 5 and 1 25 mm Adapter e Hands Free Carrier for SmartClass Fiber e Rechargeable Battery for SmartClass Fiber Li ION e PS4 Power Supply for SmartClass Fiber 12V SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P 11 CHAPTER 3 SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P Controls Standard with Patch Cord Microscope PCM QJpsu j 11 59PM 5 AN ia Jia POWER METER Connector interface OLP 82 82P only 3 5 inch color touch screen Key pad operator control panel LED indicators Patch Cord Microscope PCM with FMAE adapter HD4iP and OLP 82P only Test head cover OLP 82 82P only Battery life indicator Graphic menu interface 2x USB2 interfaces 1x micro USB interface external power supply connector G6BO0O0900900090 06 PCM controls focus control automated PASS FAIL analysis magnification control 12 USER MANUAL Getting Started CHAPTER 3
4. Glows RED when battery is low O TEST IN PROCESS Glows RED when a measurement is running in the background 4 CHARGE Glows AMBER when battery is charging If the power is OFF charging will continue with no LED indicator USER MANUAL Device Setup and Controls CHAPTER 4 Input Select Key ISK The Input Select Key allows users to inspect test certify and save results quickly on the Smart Class Fiber device Using this feature drives the user s behavior by incrementally stepping them through each application as it should be used in a proper testing workflow Pressing the ISK will immediately switch to the next application that is used in a typical workflow Once pressed a small icon will appear on the screen for a few seconds to indicate the application that is now active 1 Press gt _ from the Home Screen m switches to PCM Inspection or the next available application 2 Press from an active application m switches to the next available application as follows PCM Inspection Probe Inspection m USB OPM On board OPM a i I I NOTES Each application will only appear if it is available on the device either on board or via USB connection SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P 19 CHAPTER 4 20 SmartClass Fiber FBP HD4i HD4iP amp OLP 82 82P Home Screen Display POWER METER OLP 82P Home Screen shown with P5000i Probe and MP series USB OPM attached ru ia US 11 59
5. month year Time saved hour minute second Wavelength Frequency Press the MENU button to determine the following SELECTALL gt Selects all saved fiber images When selected a check indicator will appear in the selection box to the left of the image name DELETE gt Deletes any items with a check indicator in the selection box e ENABLE WATTS DISPLAY Check this box to include WATTS as one of the measurement values e ENABLE OPM IMAGE LINK Check this box to group the current OPM reading with the last saved inspection image All saved OPM readings will be grouped together with the last saved inspection image until a new image is stored 46 USER MANUAL Optical Power Measurement CHAPTER 6 e SYSTEM SETTINGS Shortcut to the SYSTEM SETTINGS See page 26 for further details e USERINFO Shortcut to the USER INFO See page 30 for further details Measuring Optical Power Measuring Absolute Power Absolute power measured in dBm is the amount of optical power present in the system The source of this power is the transmitter or transceiver sending information through the system This test determines whether the signal has enough power to operate the receiver or transceiver at the end of the link To measure absolute power 1 Select dBm from the menu 2 Press Select the active wavelength as described in the WAVELENGTH section below 3 The optical power measurement is displayed on the power meter dis
6. with optical power display with PON power meter meter 6 USER MANUAL Introduction CHAPTER 1 Key Features and Functions Description OLP 82 OLP 87 HD4i Portable handheld display with 3 5 color touch screen Simple graphical menu driven interface Accepts PASS FAIL P5000i Probe 2 O Accepts external USB power meter Integrated connector certification reporting On board storage Endface images and inspection analysis User definable acceptance criteria Integrated optical power meter On board storage Power meter results Integrated PON power meter BPON EPON and GPON OOOO OGeeeee CGO Integrated PASS FAIL patch cord microscope option HD4iP OLP 82P OLP 87P This User Manual will focus on the HD4i and OLP 82 products For further information on the OLP 87 or other JDSU fiber test tools visit www jdsu com test SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P 7 CHAPTER 2 SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P SAFETY INFORMATION Proper Usage This instrument is intended for measurements on optical fiber devices and systems Please make sure the instrument is not operated outside the permitted ambient conditions Always make sure that the instrument is in proper working order before switching it on Battery Information Explosion Danger A Short circuiting the batteries can result in overheating explosion WARNING Or ignition of the batteries and their surroundings Li
7. ATION Displays further information about the device 26 USER MANUAL Device Setup and Controls CHAPTER 4 BRIGHTNESS See the BRIGHTNESS section page 22 earlier in this manual for operation details DATE Once DATE is selected three fields will appear as follows MONTH DAY YEAR To set the date 1 Select one of the fields to edit NOTE The editable field will be highlighted YELLOW a7 Press the O left or right ARROW KEYS to select a field OR e Tap the desired field on the touch screen Sa 2 Once selected press the VON up or down ARROW KEYS on either the control panel or the touch screen to adjust the desired field WaZ 3 Press the O CENTER KEY to confirm SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P 27 CHAPTER 4 28 SmartClass Fiber FBP HD4i HD4iP amp OLP 82 82P TIME Once TIME is selected fields will appear as follows e 12 hour time format HOUR MINUTE AM PM e 24 hour time format HOUR MINUTE To set the time Set Time 1 Select one of the fields to edit NOTE The editable field will be highlighted YELLOW S Press the JON left or right ARROW KEYS to select a field OR e Tap the desired field on the touch screen YA 2 Once selected press the O up or down ARROW KEYS on either the control panel or the touch screen to adjust the desired field WA 3 Press the JON CENTER KEY to confirm USER MANUAL Device Setup and Contr
8. CM on the device P5000i Digital Probe The P5000i is a compact probe microscope connects directly to the device via USB2 It is specially designed to fit comfortably in hand allowing the user to inspect hard to reach connectors that are installed on the back side of patch panels or inside hardware devices QUICKCAPTURE BUTTON instantly captures and analyzes fiber image FOCUS CONTROL INSPECTION TIP t MAGNIFICATION CONTROL ji 6 FT COIL CABLE USB 2 0 CONNECTOR USER MANUAL Inspection CHAPTER 5 QuickCapture Button Instantly captures and analyzes the fiber image Focus Control Allows the user to adjust focus manually of the live fiber end face image on the display Magnification Control Allows the user to switch between LOW and HIGH magnifications of the fiber end face image NOTE For further information on the P5000i please refer to the printed FiberChekPRO Quick Start Guide that is included with the P5000i P5000i Activation 1 Select the appropriate FBPT tip that corresponds to the connector type and side being inspected and attach to probe FBPT Series Tips for the P5000i The P5000i microscope uses FBPT series inspection tips to ensure consistent and accurate inspection for a wide variety connectors and applications These connector specific and universal inspection tips are INSPECTION TIP BARREL ASSEMBLY interchangeable which allow the P5000i probe to interface with di
9. INSPECTION MENU for both P5000i and PCM PROFILE Once the inspection application is active for either the P5000i or PCM it can display a live view of the fiber end face that it is connected to The Inspection menu contains all the options necessary for setting up and using the inspection application Press the MENU key to select any of the following BRIGHTNESS BRIGHTNESS Adjusts the brightness of the display PROFILE Selects the desired PROFILE which contains the analysis PROFILE parameters by which PASS FAIL criteria are determined ay TEST Initiates the automated PASS FAIL test process TIP ADAPTER Selects the best optical settings for the type of tip TI or adapter that is attached to the microscope FREEZE Freezes a live image MORE Access additional inspection options as follows RECALL IMAGE MICROSCOPE SETTINGS IMAGE SAVE OPTIONS SYSTEM SETTINGS USER INFO MORE SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P 35 CHAPTER 5 36 SmartClass Fiber FBP HD4i HD4iP amp OLP 82 82P BRIGHTNESS Adjusts the brightness of the display See page 22 for more details PROFILE Allows the user to select from various PROFILES which contain the analysis parameters by which PASS FAIL criteria are determined Users can select from several pre configured PROFILES already on the device The pre configured profiles match the PASS FAIL criteria in the IEC visual ins
10. ION Battery Caution The Li ION Battery used in this device may present a risk of fire WARNING Or chemical burn if mistreated Do not disassemble heat above 65 C or incinerate Replace battery with manufacturer specified battery only Use of another battery may present a risk of fire or explosion Dispose of used battery promptly Never short circuit the battery contacts by touching both contacts simultaneously with an electrical conducting object Only use AA size dry batteries or rechargeable batteries Make sure the batteries are inserted with the correct polarity 8 USER MANUAL Safety Information CHAPTER 2 Ventilation Insufficient Ventilation Insufficient ventilation can damage the instrument or adversely WARNING affect its function and safety Ensure adequate ventilation when operating the instrument PS4 Universal AC DC Power Supply Safety Class The PS4 Universal AC DC Power Supply unit has a protective isolation that conforms with IEC 60950 Ambient Temperature Too High Low Temperatures outside the operating range of 0 to 40 C can WARNING damage the PS4 Universal AC DC Power Supply or adversely affect its function and safety Only operate the PS4 Universal AC DC Power Supply indoors The PS4 Universal AC DC Power Supply must only be operated at ambient temperatures between 0 and 40 C Insufficient Ventilation Insufficient ventilation can damage the PS4 Universal AC DC WARNING _ Power
11. OD Select from one of the 3 e VERIFY BUTTON BEFORE SAVE displays a confirmation box before saving an image e ONE BUTTON SAVE saves the image immediately upon pressing the save button e SAVE RESULTS IF PASS automatically saves the image if the inspection test result is a PASS e SYSTEM SETTINGS Shortcut to the SYSTEM SETTINGS See page 26 for further details e USERINFO Shortcut to the USER INFO See page 30 for further details 40 USER MANUAL Inspection CHAPTER 5 Page intentionally left blank SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P 41 CHAPTER 6 SmartClass Fiber FBP HD4i HD4iP amp OLP 82 82P OPTICAL POWER MEASUREMENT Optical Power Meter The OLP 82 and OLP 82P models feature a built in Optical Power Meter OPM with multiple calibrated wavelengths from 780 to 1625 nm The simple straightforward and intuitive user interface offers a well organized solution for measuring optical power and saving results with a portable device Universal Push Pull UPP Power Meter Input 2 5 mm VPP UPP25 or 1 25 mm VPP UPP12 interface rn 45 54 FAIL lt SET REF mm 42 USER MANUAL Optical Power Measurement CHAPTER 6 Power Meter Controls FAIL lt 35 00 dBm dB A R SET REF dB dBm Switches between Absolute dBm and Relative dB power level unit SET REF SET REF Stores a reference power level Select active wavelength
12. PM JDSU Battery Status Indicates the battery charge level status Optical Power Meter OPM Activates the on board OPM to view optical power measurement results edit acceptance criteria and view saved results Inspect PCM Activates the integrated Patch Cord Microscope PCM to inspect and analyze fiber endfaces detect scratches and defects and provide PASS FAIL results The PCM is ideal for inspecting male fiber connectors such as patch cords and test leads Inspect Probe Activates the handheld P5000i Digital Probe microscope to inspect and analyze fiber endfaces detect scratches and defects and provide PASS FAIL results The probe is ideal for inspecting connectors located behind bulkheads USB Optical Power Meter OPM Activates OPM devices such as MP 60 or MP 80 that are connected to one of the USB ports to view optical power measurement results edit acceptance criteria and view saved results USER MANUAL Device Setup and Controls CHAPTER 4 Navigating in the Menus Press the MENU key to open the context sensitive menu Depending on which application is in the foreground a different menu opens To select a menu item SAZ 1 Press the JON ARROW KEYS to highlight an item SAZ 2 To confirm press the POR CENTER KEY within the arrow keys OR press the desired button on the touch screen To leave a menu e Pressthe BACK key NOTE Actions
13. Power Supply The following power sources can be used to operate SmartClass Fiber devices e Eight 1 5 V dry batteries Mignon AA size alkaline type recommended e Eight 1 2 V NiMH rechargeable batteries Mignon AA size e PS4 Universal AC DC Power Supply optional e RBP2 Li ION Battery Pack optional Battery Operation Dangers when Handling Batteries Handling batteries may be dangerous Please note the following WARNING safety instructions Please note the battery operation safety information in Chapter 2 NOTE The battery compartment is on the back of the instrument Replacing AA Batteries Do not replace individual batteries Always change all eight batteries at the same time Always use eight batteries of the same type i e do not mix rechargeable and non rechargeable batteries 1 Open the lid of the battery compartment 2 Insert new batteries or remove the used batteries and replace them with fresh ones 3 Closethe battery compartment 4 Press the key to switch on AA batteries fully loaded in back SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P 13 CHAPTER 3 14 SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P Recharging the Batteries The rechargeable RBP2 Li ION Battery Pack will be recharged when the PS4 Universal AC DC Power Supply is being used to power the instrument The instrument switches to trickle charging automatically as soon as the RBP2 Li ION Battery Pack is ful
14. Supply or adversely affect its function and safety Ensure adequate ventilation when operating the PS4 Universal AC DC Power Supply Condensation Operation in the presence of condensation can damage the PS4 WARNING Universal AC DC Power Supply or adversely affect its function and safety Do not operate the PS4 Universal AC DC Power Supply if condensation has formed If condensation cannot be avoided such as when the PS4 Universal AC DC Power Supply is cold and is moved to a warm room wait until the PS4 Universal AC DC Power Supply Unit is dry before plugging it into the AC power line SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P 9 CHAPTER 3 SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P GETTING STARTED Unpacking the Instrument Packing Material We suggest that you keep the original packing material It is designed for reuse Using the original packing material ensures that the instrument is properly protected during shipping Checking the Package Contents The following items will be included with each SmartClass Fiber instrument Kitted packages contain additional items NOTE For customer specific kits the contents may vary according to specified configurations Standalone Units e SmartClass Fiber Instrument e Soft Bag for SmartClass Fiber and Accessories e FiberChekPRO Software Installation Disk e USB Cable USB A to Micro USB e Quick Start Guide and Safety Instructions e Dry Batteries
15. UAL Device Setup and Controls Review OPM Data Review OPM Readings BB 12 55 dem T 12 56 dBm a 12 54 dBm v E 12 54 dBm a 12 53 dBm 03 12 12 780nm 03 12 12 7s80nm 03 12 12 780nm 03 12 12 780nm 03 12 12 7a80nm E 11 53 24 2000 Hz 11 53 24 2000 Hz 11 53 24 2000 Hz 11 53 24 2000 Hz 11 53 24 2000 Hz CHAPTER 4 Opens list of OPM data saved on the device Each saved result includes the following e Measurement value e Date saved day month year e Time saved hour minute second e Wavelength e Frequency if applicable Press the MENU key to select any of the following SELECT ALL Selects all saved fiber images When selected a check indicator will appear in the selection box to the left of the image name DELETE Deletes any items with a check indicator in the selection box SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P 25 CHAPTER 4 SmartClass Fiber FBP HD4i HD4iP amp OLP 82 82P System Settings System Settings m DATE Sep 28 2012 TIME 4 53 PM 0 AUTO OFF NEVER CO TIME FORMAT 12 HOUR Ay SYSTEM INFORMATION Opens a list of general system settings When pressed the following menu will appear BRIGHTNESS Adjusts the brightness of the display DATE Adjusts the date TIME Adjusts the time AUTO OFF Adjusts the automatic switch off period of the device TIME FORMAT Selects between 24 hour or 12 hour time SYSTEM INFORM
16. age as indicated on the ratings label e Do not allow anything to rest on the power cord and do not locate the product where people can walk on the power cord e Avoid using this product during electrical storms There may be a remote risk of electric shock from lightning e Do not use this product in the vicinity of a gas leak or in any explosive environment e Do not attempt to service this product yourself as opening or removing covers may expose you to dangerous high voltage points and other hazards e Contact qualified service personnel for all service and repair Environmental Protection Please dispose of any unwanted dry batteries and rechargeable batteries carefully They should also be removed from the instrument if it is to be scrapped If facilities in your country exist for collecting such waste or for recycling please make use of these rather than throwing the batteries in with normal trash You will often be able to return used batteries to the place where you purchase new ones Any dry or rechargeable batteries that you purchased from JDSU can be returned to one of our Service Centers for disposal SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P 15 CHAPTER 3 16 SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P Operation from AC Power NOTE Only the PS4 Universal AC DC Power Supply may be used to operate the SmartClass Fiber device from AC power To fit the AC line plug adapter 1 Select the approp
17. can be operated via the operator control panel or the touchscreen The following instructions describe only touchscreen operation SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P 21 CHAPTER 4 SmartClass Fiber FBP HD4i HD4iP amp OLP 82 82P Home Screen Menu 12 30 PM ru fj 4 5 INSPECT BRIGHTNESS Adjusts the brightness of the display BRIGHTNESS MORE Access additional features and functions universal to the device RECALL IMAGE REVIEW OPM DATA SYSTEM SETTINGS USER INFO PC CONNECT MORE BRIGHTNESS Adjusts the brightness of the display Once the BRIGHTNESS button is selected WAY 1 Press the JOR left darker or right brighter ARROW KEYS to adjust the brightness level SE 2 Press the ON CENTER KEY to confirm your selected brightness level v OR use the touch screen as follows Tap the desired arrow buttons to adjust the brightness level Tap the OK button to confirm your selected brightness level 22 USER MANUAL Device Setup and Controls CHAPTER 4 Recall Image Recall Image E FIBER 001 O9 O07 12 13 48 23 Pass O9 07 12 13 48 35 Pass OO O7 12 15 48 47 Pass O9 07 12 13 51 29 Pass BBC einy riser 003 BE riser 004 Opens list of fiber images saved on the device Select one or multiple saved fiber images to view further details including analysis results Once RECALL IMAGE is selected Ta e Press the ODN up and do
18. e C CENTER KEY or use the touchscreen to check or uncheck this box 7 USER MANUAL Optical Power Measurement CHAPTER 6 Wavelength value REF gt Displays a stored reference value in dBm Limit gt Displays a set limit value if defined For further details see the ENTER LIMIT section below e Press the MENU button for the following ADD WAVELENGTH gt Activates a numeric keypad to enter additional wavelengths ENTER REFERENCE gt Activates a numeric keypad to manually enter a Reference Threshold DELETE WAVELENGTH gt Deletes the current highlighted wavelength ENTER LIMIT gt Activates a numeric keypad for entering a threshold for the lowest acceptable value If the OPM value being measured is lower than the acceptable threshold then the word FAIL will appear on the MAIN OPM screen with an explanation that is below the acceptable limit SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P 45 CHAPTER 6 SmartClass Fiber FBP HD4i HD4iP amp OLP 82 82P e REVIEW OPM DATA Review OPM Readings BB 12 55 dem E 12 56 dBm T 12 54 dBm g 12 54 dBm a 12 53 dBm 03 12 12 780 0nm 03 12 12 780nm 037 12 12 Ta nm 03 12 12 780nm 03 12 12 780nm E 11 53 24 2000 Hz 11 53 24 2000 Hz 11 53 24 2000 Hz 11 53 24 2000 Hz 11 53 24 2000 Hz Opens list of OPM data saved on the device Each saved result includes the following Measurement value Date saved day
19. een and enter the data using the alpha numeric keypad on the screen 30 USER MANUAL Device Setup and Controls CHAPTER 4 PC CONNECT PC CONNECT is used to establish or re establish a connection between the device and a PC using the included USB A to Micro USB cable Once connected users can export any of the stored data from the device to the PC using the included FiberChekPRO software program The device will automatically establish connection with the PC once both ends of the USB A connects to PC to Micro USB cable connects to device are connected Once connected a message will appear on the device s display screen stating that it is connected to the PC If this connection is lost this message will disappear The connection will be re established by selecting PC CONNECT SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P 31 CHAPTER 5 SmartClass Fiber FBP HD4i HD4iP amp OLP 82 82P INSPECTION P5000i Probe Microscope Controls 32 Hardware Overview Inspection of fiber optic interconnects is essential for the optimal performance and longevity of fiber optic connectivity SmartClass Fiber devices have the capability to inspect end faces provide PASS FAIL analysis and store the results directly on the device Inspecting fiber endfaces with SmartClass Fiber devices is accomplished with a P5000i Digital Analysis Microscope In addition certain configurations are equipped with an Integrated Patch Cord Microscope P
20. er FBP HD4i HD4iP and OLP 82 82P 49 SmartClass Fiber FBP HD4i HD4iP amp OLP 82 82P ORDERING INFORMATION Standalone Units Part Number Description FBP HD4i HD4i Digital Handheld Video Display FBP HD4iP HD4i Digital Handheld Video Display Dual Mag Patch Cord Module 2315 05 OLP 82 Digital Handheld Video Display Integrated Optical Power Meter 2315 03 OLP 82 Digital Handheld Video Display Integrated High Power Optical Power Meter 2316 01 OLP 82P Digital Handheld Video Display Dual Mag Patch Cord Module Integrated OPM 2316 03 OLP 82P Digital Handheld Video Display Dual Mag Patch Cord Module Integrated High Power OPM Kits Part Number Description FBP SD4i HD4i Basic Kit FBP SD4i PRO HD4i Pro Kit FBP SD4iP HD4iP Basic Kit FBP SD4iP PRO HD4iP Pro Kit FIT 8201 OLP 82 Basic Kit FIT 8201 PRO OLP 82 Pro Kit FIT 82P01 OLP 82P Basic Kit FIT 82P01 PRO OLP 82P Pro Kit FIT 82P03 OLP 82P High Power Basic Kit FIT 82P03 PRO 50 OLP 82P High Power Pro Kit USER MANUAL Included Items Standalone Units SmartClass Fiber Instrument Soft Bag for SmartClass Fiber and Accessories FiberChekPRO Software Installation Disk USB Cable USB A to Micro USB Quick Start Manual and Safety Instructions Dry Batteries 8x Additional Items in Basic Kits P5000i Digital Inspection Microscope Inspection Tips and Adapters Bulkhead SC and LC Patch Cord 2 5 and 1 25 mm 1 25 mm OPM Adapter OLP 82 82P Additional Ite
21. es between HIGH or LOW magnification MORE Access additional inspection options NOTE This is the same list of options that can be accessed at the Inspection Menu when in a LIVE state see page 35 SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P 37 CHAPTER 5 38 SmartClass Fiber FBP HD4i HD4iP amp OLP 82 82P TIP ADAPTER Allows the user to select the best optical settings for the type of FBPT Tip or FMAE adapter that is attached to their microscope Text displays TIP TIP When using P5000i Text displays ADAPTER ADAPTER When using PCM Users can select from the list of pre configured optical settings For further information on optical settings see the FiberChekPRO user manual on the included software installation disk or visit http www jdsu com inspect and download the FiberChekPRO software FREEZE Allows the user to freeze a live image Once the image is frozen pressing the MENU button again gives the following additional options LIVE Returns to a LIVE view of the image MAG Toggles between HIGH or LOW magnification MORE Access additional inspection options NOTE This is the same list of options that can be accessed at the Inspection Menu when in a LIVE state see page 35 MORE Access additional features and functions associated with inspection e RECALL IMAGE Opens list of fiber images saved on the device Selec
22. es ssecscacsissssnssssessnesaconsensevzeonssnssvsasvtssnssesstonsndveeraunssneensenievnveonies 13 Recharging the Batteries ccssssssssssssscsssssessessssssssssesscssssscssssssecsecsseassesseeseenees 14 Using or Replacing the RBP2 Li ION Battery Pack essssessessscesseceeseeees 14 General Tips ON Using Batteries esessessesscsessesssssesecsesssssssscsecssescsscsssssscseesseassesseess 15 Other Basic Safety PrecautionS ssssssssssssssseeesssssseeeessssssrersssssseeseossesseessssseseeessssseeeees 15 Environmental Protection csaurmnvniinunieninmniomunuamnunnmaienpiniomaatnns 15 Operation from AC POWEL s sssssesssssessssseesssseessssseeesssseeossseesssseeeosseeronssstesssseoessseeeossseessssees 16 SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P 3 Table of Contents CHAPTER 4 DEVICE SETUP AND CONTROLS 00 cccccsesssssssssssssessssessssessssesscsessssessssesssseesssessees 18 31 Operator Control Panel siscscsiaineriouniienncsiiaiadounceiiiranncuinaminwd 18 Input Select Key ISK oscccerctrasccasienaseac esanicea iain dime cect aan atiniuenteumaocun 19 Home Screen Display sa cicazetsceccetisnaraanstaipeseanesians ineneincraasiaominindaautnstietiasannianan 20 Navigating in the Men s cswimwiusseriinanoenm n n 21 Home Screen MenU s ssesssssesseessessesseessesseesecssesssesseoseossesseeseessessseseeoseossesseeseessesseeserssesseesses 22 Recall AO niinn a A a 23 Review OPM Dat a s eseesseessesssessssesssesseesseeeseessseo
23. fferent types of fiber connectors 2 Plug your P5000i into a USB port on the device 3 Connect the P5000i with the fiber being inspected C 4 Press the A HOME key then select Ca INSPECT Probe SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P 33 CHAPTER 5 34 SmartClass Fiber FBP HD4i HD4iP amp OLP 82 82P Integrated Patch Cord Microscope PCM Certain SmartClass Fiber devices are also configured with an additional on board PCM which allows users to inspect both ends of a fiber connection much faster than with a single probe microscope FMAE Series Adapters for the PCM SmartClass Fiber devices with the PCM use FMAE series adapters to ensure consistent and accurate inspection for a wide variety connectors and applications All PCM configurations ship with an included 2 5 mm interface Kitted configurations include additional FMAE adapters QuickCapture Button Instantly captures and analyzes the fiber image Focus Control Allows the user to adjust focus manually of the live fiber end face image on the display Magnification Control Allows the user to switch between LOW and HIGH magnifications of the fiber end face image PCM Activation 1 Select the appropriate FMAE adapter that corresponds to the connector type and side being inspected and attach to PCM 2 Press the al HOME key then select a INSPECT PCM USER MANUAL Inspection CHAPTER 5
24. ly charged NOTE Rechargeable AA Batteries will not be recharged in the instrument For AA type rechargeable batteries please use an external charger For ordering information see page 49 Using or Replacing the RBP2 Li ION Battery Pack 1 Open the lid of the battery compartment 2 Remove the AA battery tray FITP RBT1 or existing FBP2 Li ION battery NOTES e Dispose of used batteries promptly e Keep away from children e Do not disassemble and do not dispose of in fire 3 Replace with FITP RBP2 e IMPORTANT Replace Li ION Battery with FITP RBP2 only 4 Closethe battery compartment 5 Press the O key to switch on RBP2 Li ION Battery Pack installed USER MANUAL Getting Started CHAPTER 3 General Tips on Using Batteries e Always handle batteries with care e Do not drop or damage the batteries or expose them to excessively high temperatures e Do not store the batteries for more than one or two days at very high temperatures e g in a vehicle either separately or fitted in the instrument e Do not leave discharged batteries in the instrument for a long time if it is not being used e Dispose of used batteries promptly e Keep away from children e Do not disassemble and do not dispose of in fire Other Basic Safety Precautions e Do not use PS4 Universal AC DC Power Supply outdoors or in wet or damp locations e Connect the PS4 Universal AC DC Power Supply to the correct mains volt
25. ms in Pro Kits P5000i Digital Inspection Microscope Inspection Tips and Adapters Bulkhead SC and LC Patch Cord 2 5 and 1 25 mm 1 25 mm OPM Adapter OLP 82 82P Cleaning Materials for 2 5 and 1 25 mm Bulkhead and Patch Cord Hands Free Carrier for SmartClass Fiber Rechargeable Battery for SmartClass Fiber Li ION FFL 050 Visual Fault Locator with 2 5 and 1 25 mm Adapter Power supply for SmartClass Fiber 12V Accessories Part Number Description FBPP PS4 Power Supply for Smart Class Fiber 12 V FITP RBP2 Rechargeable Battery for SmartClass Fiber Li ION FITP RCG1 Kit RBP2 Rechargeable Battery PS4 Power Supply FITP RBT1 Replacement Battery Tray FITP UC4 UC4 Hands Free Carrier for SmartClass Fiber FITP UC4P UC4P Hands Free Carrier for SmartClass Fiber with PCM VPP UPP12 Adapter U12 for OLP 82 82P VPP UPP25 Adapter U25 for OLP 82 82P FBPP SCASE2 SCASE2 Soft Shoulder Case for SmartClass Fiber Tools Test and Measurement Regional Sales NORTH AMERICA LATIN AMERICA ASIA PACIFIC EMEA www jdsu com inspect TEL 1 866 228 3762 TEL 1 954 688 5660 TEL 852 2892 0990 TEL 49 7121 86 2222 FAX 1 301 353 9216 FAX 1 954 345 4668 FAX 852 2892 0770 FAX 49 7181 86 1222 Product specifications and descriptions in this document subject to change without notice 2012 JDS Uniphase Corporation September 2012 22002224 REV 0
26. ols CHAPTER 4 AUTO OFF Once AUTO OFF is selected the following list will appear Auto Off Settings AUTO OFF 30 MIN AUTO OFF 20 MIN AUTO OFF 10 MIN AUTO OFF 5 MIN e Chose the desired time duration from the list to determine when the device will automatically turn OFF Sa e Pressthe lt CP CENTER KEY or tap the touch screen to select the desired time limit Y TIME FORMAT Select the desired time format 24 hour or 12 hour that the device will display A Z N e Pressthe lt CENTER KEY or tap the touch screen to select the desired N 4 4 format SYSTEM INFORMATION Displays further information e g Serial Number Board Revision Firmware Version Battery Strength Up time about the device This screen is informational only and does not include anything that can be changed SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P 29 CHAPTER 4 SmartClass Fiber FBP HD4i HD4iP amp OLP 82 82P USER INFO User Information ADDRESS gt 18471 Bothell Everett Hwy CUSTOMER FiberTech Int LOCATION Mill Creek WA JOB ID 1635y298y32 OPERATOR Joe Schmoe The USER INFO menu allows you to enter information about your organization including the company name address customer location job ID operator cable ID fiber ID and any comments about the job Edit Company JDSU To edit any of these fields select the desired field via NAVIGATION KEYS or touch scr
27. pection standard IEC 61300 3 35 All of these profiles are factory set and cannot be edited or removed e SM UPC IEC 61300 3 35 e SM APC IEC 61300 3 35 e MM IEC 61300 3 35 e Ribbon SM APC IEC 61300 3 35 e Ribbon MM IEC 61300 3 35 e SM PC IEC 61300 3 35 Additional profiles can be created added and or removed from the SmartClass Fiber device when used in conjunction with the included FiberChekPRO software program For further information on profiles see the FiberChekPRO user manual on the included software installation disk or visit http www jdsu com inspect and download the FiberChekPRO software USER MANUAL Inspection CHAPTER 5 TEST Initiates the automated PASS FAIL test process NOTE Initiating a test can also be done by pressing the QuickCapture button directly on the P5000i Probe or PCM Once the test is complete The result will flash on the screen as either PASS or FAIL In addition the outside edge of the image will be highlighted in either GREEN to indicate PASS or RED to indicate FAIL When in the Test view pressing the MENU button again gives the following additional options LIVE Returns to a LIVE view of the image VIEW Toggles overlay view options 3 states e NO OVERLAY image only view e RINGS image with overlay of zones and defects e RINGS TABLE image with overlay of zones defects and a summary table with the analysis result for each zone MAG Toggl
28. play SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P 47 CHAPTER 6 48 SmartClass Fiber FBP HD4i HD4iP amp OLP 82 82P Measuring Attenuation Relative Power Relative power level attenuation measurement is the amount of power lost attenuated by the optical link being tested measured in dB The source of this power is typically a handheld optical light source This test determines whether the optical link is constructed properly either as a qualification test or when troubleshooting the network To measure attenuation you must 1 Geta reference measurement by selecting SET REF on the menu Once the reference is set 0 00 dB is displayed in the main OPM window The referenced value will also appear on the display 2 Get an attenuation measurement a Disconnect reference fiber 1 from the power meter DO NOT disconnect reference fiber 1 from the light source OLS b INSPECT and if necessary CLEAN all ends of the system port c Connect reference fiber 1 to the system port d INSPECT and if necessary CLEAN all ends of reference fiber 2 e INSPECT and if necessary CLEAN the fiber at the far end of the optical fiber link f Connect reference fiber 2 to the system port g The attenuation measurement insertion loss of the optical link is displayed in the main window of the power meter USER MANUAL SmartClass Fiber FBP HD4i HD4iP amp OLP 82 82P SPECIFICATIONS General OPM General technical Typical a
29. riate AC line plug adapter 2 Slide the AC line plug adapter into the slot PS4 Universal AC DC Power Supply is ready for use To change the AC line plug adapter 1 Squeeze both sides of the PS4 latch lock 2 Push the AC line plug adapter upwards 3 Slide a different AC line plug adapter into the slot USER MANUAL Getting Started CHAPTER 3 To operate the SmartClass Fiber device from AC power 1 Connect the PS4 DC power cord to the DC power socket on the device The socket is under the cover on the right side 2 Plug the PS4 into the AC line socket NOTE The PS4 provides power even if dry or rechargeable batteries are fitted in the instrument SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P 17 CHAPTER 4 18 SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P DEVICE SETUP AND CONTROLS Operator Control Panel HOME Press to go to the home screen MENU Press to open a menu BACK Press to go back one step Ns iil gt INPUT SELECT KEY ISK Press for fast toggling between device functions See page 19 for more information on using the ISK POWER Press to switch the instrument ON and OFF NOTE LED glows GREEN when the instrument is ON N a Pi ARROW KEYS 4 gt e Press to navigate through the menus fo e Press to change values in the menus y CENTER KEY e Press to confirm the selection H SAVE Press to save results I LOW BATTERY
30. sseosseesseesseosseosseeseeesseeoseosseosseessersseroseeesees 25 SAAE ae E 26 PONI S aa E anes ante E A nw aa eee 27 ETAR D F i ee en EEE A A E EES rere rene 27 Tal 9 eee nner een ener OP LO Prete vO fer ee on eee ee ee 28 Auto OF SEIN OS eneen R 29 AERAN rs emer eee nee nee eer ener E erie EA 29 System LOGIT ICICI cs shy vacarescarsosniciantunstansiateerdeeet aon aaenehidoastsiannieemacucas nadernet 29 Wisc ilai 3 dagreidle q peeeereetrenme ee enn emer NA RN 30 LELE E carga EEEE A EE EAE E sct as E 31 CHAPTER 5 INSPEC TION ssoep cee cseniereratvesees eee eserves teresa ten eee pps eee 32 38 Hardware OvervieW sseessesssessseesssesscesseesseesssessscoseeeserenscosseosseoseeesscescosseesseeseerssresseessees 32 P5000i Digital Probe sneitorattaderatneatsnircenimansantnmnieiseueemauraeee 32 P5000 ACtVAtO nsnsi eneen Eee ER Nia 33 Integrated Patch Cord Microscope PCM es ssssessssessssessssessssesssssossseesssesssseessseosssees 34 PEM ActiVatiO Miesen eE a EE A EEE E EEE 35 Inspection TAU staf rt ve anesta te per esnena deters catsasteteesseraere antpans eter va osiot es siia attests 35 Brig NUNES serinseisiiriinioietrideisaniina sev rrain tirenn Eiin AnA SEE REEERE 36 Fy VOTES e A A OAN OER 36 EE EEE E A EAE E 37 Up AQAPtE eneren E NE E EE E E E EA E 38 ERAI A AIE E EE E E A E E E NAE TE 38 NAET RE E EE T EOE AOE AINEEN 38 4 USER MANUAL Table of Contents CHAPTER 6 OPTICAL POWER MEASUREMENT ccccscssssssssss
31. sssssssssssssessessessessesseneessenseseessees 42 47 Power Meter OS arses esc acta cece eects eed eects eee eee 43 OB OB Preece te te Mee A TTT PR Tat tenn TTT tr TT enter en erty Tren ene me cr 43 Sole IAI ALE Fr aa E E N E 44 De PY ELEN GT cadet ncaa nep a doused ted eee teach euceesetccones A4 MORE sapre T A E 44 Measuring Optical Power sssesssssessseessssessseessssesssseossseossseossseossseossseosssrossseessseossseessseesssees 47 Measuring Absolute POWE f e sseesssssessseessesessseessesessseesseeeosesesseeeoseseosesessseessesesss 47 Measuring Attenuation Relative Power sssesssseessssessesessesessseessssessseesseeesss 48 SPECIFICATIONS soca eect 49 ORDERING INFORMATION c cccscssssssssssesssscssssssssscsessesssscsessesscsecsesseeucsecaseassucsecseenses 50 SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P 5 CHAPTER 1 SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P INTRODUCTION JDSU s SmartClass Fiber family is the next generation of optical handheld test solutions that allow technicians to inspect test certify and save on a single device Designed to help users work smarter and faster the SmartClass Fiber family incorporates the features that technicians rely on every day to deliver best in class reliable networks to their customers Products in the SmartClass Fiber family include HD4i OLP 82 OLP 87 Digital handheld video Digital handheld video Digital handheld video display display
32. t 25 C General technical Typical at 25 C Weight 1 2 lb Display range 1 4 Ib for PCM version Standard 65 to 10 dBm DIM encOne aD High power 50 to 26 dBm OLP 82 HD4i 20 83 x 11 18 x 6 35 cm Max input level permitted 8 2x 4 4 x 2 5 in Standard 10 dBm OLP 82P HD4iP 20 83 x 152 4 x 6 35 cm High power 26 dBm 8 2x6 0x 2 5 in Standard wavelength settings 850 980 1300 Video display 3 5 in color LCD 4 3 ratio 1310 1490 1550 1625 nm Keypad 11 2 dome buttons membrane panels Intrinsic uncertainty 0 20 dB 5 4 LED indicators ET Linearity 0 06 dB Connector USB 2 0 50 to 5 dBm 2 x host Type A 1 x device Micro B Wavelength range 780 to 1700 nm Power source 12V 2A adapter battery Wavelength and modulation 8X AA alkaline or rechargeable Li ION USB port Result display dBm dB MW Run time Resolution l 0 01 dB Rechargeable Li ION minimum 8 hours oils frequencies 270Hz 1000Hz ee 8X AA alkaline 5 hours Power mode Active Auto off Auto shutoff time user programmable Video Display Charge time AC adaptor 8 hours General technical Typical at 25 C Saved images gt 1000 Live image 320 x 240 x 8 bit gray 10 fps Saved OPM data gt 10 000 Light source Blue LED 100 000 hour life Certification CE IEC EN61326 Lighting technique Coaxial Warranty 1 year Low magnification field of view FOV Horizontal 740 um Vertical 550 um High magnification field of view FOV Horizontal 370 um Vertical 275 um SmartClass Fib
33. t one or multiple saved fiber images to view further details including analysis results See page 23 for more details USER MANUAL Inspection CHAPTER 5 e MICROSCOPE SETTINGS Opens a list of system settings specific to the microscope functionality When selected the following options will appear Microscope Settings AUTO CENTER Q SHOW FOCUS METER AUTO CENTER e Check box to turn AUTO CENTER ON e Uncheck box to turn OFF DEVICE BUTTON Selects the desired function of the QuickCapture button e TEST initiates the automated PASS FAIL test process e CAPTURE freezes image SHOW FOCUS METER eCheck box to turn FOCUS METER ON e Uncheck box to turn OFF NOTE The FOCUS METER is a visual gauge that aids the users in finding the optimal focus point As the image comes into focus the length of the blue bar increases A red line will show the highest level achievable for each endface Optimal focus level is reached when the blue bar is closest to the red line at the highest point possible SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P 39 CHAPTER 5 SmartClass Fiber FBP HD4i HD4iP amp OLP 82 82P e IMAGE SAVE OPTIONS Allows the user to specify how they want to save an image Options include the following FILE NAME BASE Allows user to define a base level name for saved images Selecting this option opens an alphanumeric keypad for entering the base level text ARCHIVING METH
34. tandards USER MANUAL TABLE OF CONTENTS CHAPTER 1 INTRODUCTION orccsennisssennnnnnenein TO mr Ven nape op nee nv EE Inne Pr 6 7 SmartClass Fiber BY sht cl 21 ee eee ne ene nen cay ee nnee nnn ee RIE ee Tere nne Seer 6 Key Features and Fun ctionss scsscsscssssscsscssssscsssnsssssssssssssssscsssssesscasesscssessssseasesseasenscees 7 CHAPTER 2 SAFETY INFORMATION sssnesssssseseesssssseseesssssseeesssssseeressssseeeesssssseeeeosseneresesssesreesssssereessss 8 9 AOLO E E E A E AAE EE E T 8 Battery Informatio ssssnsenneinenmonnini ia eee eee 8 LENE 6 E E N E N ES PEE AA E E T E AA ET 9 PS4 Universal AC DC Power SupplY sssssssssssssssseessssssseeesssssseeseessesseesessseseeosssssreeessssseeee 9 CHAPTER 3 GET TUNG STARTE Decco cee sone cas exe tas antes aaa aees easels 10 16 Unpacking the INStrUMe Nt cessssessssesssssssecsecscsnssscsecscsecsecsssessecsecsssnsscsecssensseeaeeseeess 10 Packing MGT al vssssssssvavscnsasietevassiensiinang inca aaa N 10 Standalone AIS tcc ce ceecee ech eee ee eee 10 Additional Items in Basic Kits sssissevsssessessinetancesssesennvonsansievesmancimnineeiavers 11 Additional Items in Pro KItS sciisssensssseisstessstovavinssnetannisseetonsitianieroneaenionndeds 11 CONO S a A A a 12 Power UPD meter are mune tenner net ner tr tae a a a Tor OTe 13 Battery OA cscs atc cale sce envas hes ccaes dasarisad auc foentiacd edharbtesttabediaictintvareastece niisiis 13 Replacing AA Batteri
35. wn ARROW KEYS to browse through the list of saved images ONA e Press the y cc CENTER KEY to select one or multiple saved fiber images e Press the MENU key to select any of the following SELECT ALL Selects all saved fiber images When selected a check indicator will appear in the selection box to the left of the image name CLEAR ALL Clears all check indicators in the selection boxes DELETE Deletes any items with a check indicator in the selection box SmartClass Fiber FBP HD4i HD4iP and OLP 82 82P 23 CHAPTER 4 SmartClass Fiber FBP HD4i HD4iP amp OLP 82 82P FIBER 000 MAG VIEW Opens the saved image for all selected items starting with whatever image is highest in the list of saved fiber images Once a saved image appears users can press the MENU button for additional options PREV Opens the previous fiber image selected from the list of saved fiber images if applicable MAG Toggles between low and high magnification NO OVERLAY RINGS RINGS TABLE Toggles between overlay view options for the selected image NO OVERLAY Image only view RINGS Image with overlay of zones and defects RINGS TABLE Image with overlay of zones defects and a summary table with the analysis result for each zone INFO Provides further information on the displayed fiber image NEXT Opens the next fiber image selected from the list of saved fiber images if applicable 24 USER MAN