1. 2 Doors 3 Doors 4 Doors 5 Doors 6 Doors 7 Doors E E on U l 8 Doors When CAT has no doubts about the correct detection it informs you about the result and prepares assignment of the correct parameters logical address and master slave mode for the corresponding sensor Identify Sensors and Configure System B Identified as 11_00553 Start Detection Door Count Door Types Sensor Assignments 1 Door 93 2 Doors 3 Doors 4 Doors 5 Doors 6 Doors 7 Doors A 2 s a e F 8 Doors 2 Apply This Configuration D Leave Configuration Untouched As long as there are no problems CAT will tell you to go on like this for the remaining sensors and or doors Potential problems that might arise are e Detection is ambiguous because several sensors show the expected data signature created by the paper e You cover the same sensor twice e Severe problems on the CAN bus or sensor s prevent communication In all cases CAT shows a warning and instructs you to repeat the last instruction e g CAN Address Tool 3 x Manual Rev 02 doc 13 17 Project Content Author IRMA CAN Address Tool User s Manual Christian Klemke Identify Sensors and Configure System Start Door Count 1 Door e 2 Doors 3 Doors 4 Doors CB Doors 6 Doors 7 Doors C 8 Doors i Stop i Detection Sensor Assignments Not In Use Not In Use Not In Use Not In Use A y 2 Apply This
2. CAN IRMA baud rate is 500 kbps As a rule of thumb you can assume that most IRMA 3D systems work at 1 Mbps if not more than 4 DIST4 sensors are connected to IRMA A21 analyzer and system installation was done before 2008 CAN Address Tool 3 x Manual Rev 02 doc 5 17 Project IRMA CAN Address Tool Content User s Manual 11 04 2008 Author Christian Klemke Rev 02 5 2 CAN communication start and device scan Next click the Start CAN Commun Button in the control area This initializes the CANusb converter and starts up the CAN communication If the CANusb converter can not be found or signals any problems an error message is shown and the application terminates immediately X CANusb is not available Please check power and cabling and restart Otherwise CAT will now start to continuously scan the CAN bus for already or newly connected sensors Once one ore more sensor s have been detected their addresses will be displayed in the list and the tool will start reading out their configuration data A IRMA CAN Address Tool Stop CAN Commun List of connected sensors Serial No Address Type MIS CANSpeed Status HR Mode 4 222 0x2C227 22 222 222 222 ere 2 a 222 0x2C229 222 22 222 222 1797 a 229 0x346E9 22 229 229 229 299 222 222 Ox346EA CAN Speed 500 ki Enable Sounds ShowEventLog Show Details 5 3 Sensor configuration overview When the configuration downloads are finished the initi
3. delivered by iris to the customer in the right configuration 6 Appendix A List of IRMA hardware components Description Iris product name Iris order number Power only CAN adapter cable KQ A21 CAN 01 15cm 0205 12 Softing CANusb converter CAN USB Konverter einkanalig 0301 10 7 Appendix B Supported software 7 1 CANusb converter e CANusb device driver installed from CAN_LAYER2 V411 zip or higher e CANusb dll version 4 1 0 1 or higher 7 2 IRMA DIST4 sensor firmware e Firmware can 4d28 can_4d31 and can_4d32 used for IRMA Sensors DIST4 0x x 4 6 e Firmware atm_08 or higher in case of DIST4 08 and DIST4 1x CAN Address Tool 3 x Manual Rev 02 doc 16 17 Project IRMA CAN Address Tool Content User s Manual 11 04 2008 Author Christian Klemke Rev 02 e Older firmware may work with limitations This is especially true for firmware can 4d25 and can_4d26 used for IRMA Sensors DIST4 0x x 1 3 7 3 IRMA A21 analyzer firmware e IRMA Opera version 2 99f or newer is mandatory e g as found in firmware files SDIST4 AA21CG IZZ CS 3 26 PV 3 11 HEX or SDIST4 AA21C8 Cl 5 14 IMZZZ_ PV 4 39 HEX 7 4 Operating Systems e Windows Vista if IRMA CAN Address Tool is running with administrator rights e Windows Server 2003 or Windows Server 2008 e Windows XP quality assurance test or Windows 2000 quality assurance test e Windows ME Windows 98 SE quality assurance test CAN Address Tool 3 x Manua
4. present in the same directory as the application itself Please refer to Appendix B for details CAN Address Tool 3 x Manual Rev 02 doc 4 17 Project IRMA CAN Address Tool Content User s Manual 11 04 2008 Author Christian Klemke Rev 02 5 The main window Once you start the application a splash screen shows up on the screen center er 5 1 User interface structure Just a few seconds later the main application window is displayed A IRMA CAN Address Tool List of connected sensors Serial No Address Type MIS CANSpeed Status HR Mode CAN Speed 500 kBit s y Enable Sounds Show EventLog Show Details As you can see the window is split up into four regions e Control area hosts the start stop and refresh button e Sensor list shows the currently detected sensors and their configuration e Reconfiguration area contains multiple action buttons to do different kinds of sensor reconfigurations e Option area allows for selection of CAT operation parameters As first action after startup you have to select the baud rate that is appropriate for your bus constellation The baud rate selector CAN Speed is located on the bottom left of the main window If you are unsure abtout the correct value ask the iris project team which speed to choose The application will save and restore the last selected baud rate between sessions using file IrmaCanAddressTool ini Currently default
5. to your system Confirmation 2 3 sensor s have to be reconfigured Do you want to proceed This is your last change to abort the process if you go on by clicking Yes a progress window appears The status column will soon show Success for all sensors Adjust Logical Address Assignments List of connected sensors a 13 01769 1 0x01 DIST4 08 Master M Success a 11_00551 2 0x02 DIST4 02 Master M Success a 11_00553 3 0x03 DI5T4 02 Slave M Success After that you get a last confirmation message Information i Configuration update s done Clicking OK brings you back to the main window where the sensor list will be refreshed completely 5 7 4 Set System CAN Speed A global parameter of a CAN IRMA system is the CAN bus speed also called baud rate Iris uses two speeds namely 500 kBit s and 1000 kBit s 1 MBit s All components on the bus sensors and analyzer as well as CANusb device in case of sercive have to operate at the same CAN speed otherwise all kinds of communication problems can arise If you ever need to reconfigure a system s CAN speed CAT offers an option to do so To use it click the Set System CAN Speed button in the main window A window showing the current settings will pop up as follows Set CAN Speed Configuration For All Sensors List of connected sensors SerialNo Address TypeName CAN Speed Progress CumentTask Status 11_005
6. 0 6 0x06 DIST4 08 Master 500kBi s Vaid A GrayCoEm am 08 ATMEL 1GkBk 201 3 Check Configure Set System System 2 System CAN Speed A ECO Analyzer 23_0676 0x5C2A4 is present in system Note Displaying the details is usually only necessary in case of severe problems However the additional info might help iris staff to provide proper support 5 4 Error detection during device scan Any problems that might occur during device scans are indicated to the users e g Warning other sensors and connect the cable KG 421 C4M 01 power only between the analyzer and the sensor Iris part number of this Attention The software of sensor 11_00551 allows to operate with one single sensor at the IRMA CAN bus Please disconnect all cable is 0205_12 Warnung You have not detached the analyzer with the power only adapter cable This is not allowed if old sensors software before can_4d28 are used Please refer to type label Warnung At least one E2PROM read error has occured This indicates that more than on old sensor software before can_4d28 is connected This is not allowed Please refer to type label Warnung A Only one sensor with software before can_4d28 may be connected to the CAN IRMA bus Please refer to type label CAN Address Tool 3 x Manual Rev 02 doc 7 17 Project IRMA CAN Address Tool Content User s Manual 11 04 2008 Author Christian Klemke Rev 02 or Warning Sensor 13_01769 0x346E9 repor
7. 10 A SCV EOR CAN DE a gienge ans tade tava esau sha ket tamseagiesia eats 15 6 Appendix A List of IRMA hardware components cccceecceseceesceeeeceeccceecceeccuseceeceeeeceuseees 16 7 Appendix B SUD DOME SOMW ad SEA abvees 16 Fh EANUSO CON Veneno 16 12 NIRNVACDIS TAE Sensor INWTE a aia 16 Fa IRMA Fanal yzer WAE iaa aaa 17 e OPE Se SV SUC NS E E E E AEE EAE ee 17 CAN Address Tool 3 x Manual Rev 02 doc 2117 Project IRMA CAN Address Tool Content User s Manual 11 04 2008 Author Christian Klemke Rev 02 1 Introduction An essential part of the IRMA CAN system concept is a PC service software known as IRMA CAN Address Tool This document is a short manual describing the features of this application and tries to show its usage Its target audience are iris customers and third party people who will be using the tool The reader should be familiar with the technical concepts of an IRMA CAN system Setting up a correct and working CAN bus is out of the scope of this document 2 Requirements and Limitations The CAN Address Tool CAT is part of the so called IRMA A21 Windows Suite which a set of software components needed to perform service tasks with IRMA A21 systems Usually these A21 related service application are installed properly by a higher level setup tool called IRMA Setup exe which ensures path consistency and error free collaboration Updates of CAN Address Tool might be made available for separate download from
8. 51 1 0x01 DIST4 02 500 kBit s 11_00553 2 0x02 DIST4 02 500 kBit s 13 01769 30x03 DIST4 08 500 kBit s Configure Sensors to 500 kBits s Configure Sensors to 1000 kBits s You can then click on the appropriate Configure Sensors to kBits s button If any changes are necessary CAT shows a message box and requests you to confirm the change CAN Address Tool 3 x Manual Rev 02 doc 15 17 Project IRMA CAN Address Tool Content User s Manual 11 04 2008 Author Christian Klemke Rev 02 Confirmation 2 3 sensor s have to be reconfigured to work at 1000 kBit s Do you want to proceed j Cancel CAT will then open a progress window where the status column will soon show Success for all sensors Set CAN Speed Configuration For All Sensors List of connected sensors 11_00551 1 0x01 DIST4 02 1 MBit s 11_00553 2 0x02 DIST4 02 1 MBit s 1301769 3 0x03 DIST4 08 1 MBit s M Success H Success H Success As a reminder to the fact that the baud rate change itself will not take effect before a power reset the applications shows you a final message box at application exit if you have changed the baud rate during your session Warnung You have changed a baud rate setting at least once Please do not forget to apply a power reset on the system Note You should usually not change the baud rate setting unless you really know what you are doing Analyzers and sensors are normally
9. Configuration Tt Leave Configuration Untouched Identify Sensors and Configure System Start Door Count 1 Door e 2 Doors C 3 Doors 4 Doors CB Doors C 6 Doors C 7 Doors C 8 Doors i Stop i Detection Sensor Assignments Not In Use Not In Use Not In Use N ot n L se Not In Use 4 2 2 Apply This Configuration SM Leave Configuration Untouched 11 04 2008 Rev 02 When all sensors have successfully been identified CAT signals green light and enabled the Apply This Configuration button on the window bottom Of course you can also choose the leave the windows without modifications at any time or to interrupt the process Identify Sensors and Configure System Door Count 1 Door e 2 Doors 3 Doors C 4 Doors C 5 Doors C 6 Doors C 7 Doors C 8 Doors Detection successfully finished Sto p i Detection Door Types ss Sensor Assignments m1 Naon sensa y Doors Sensor M S Sensor Addr Sensor Serial 2 Wide 2 Sensas y Not In Use Not In Use Not In Use Not In Use Not In Use 7 Apply This Configuration K5 Leave Configuration Untouched CAN Address Tool 3 x Manual Rev 02 doc 14 17 Project IRMA CAN Address Tool Content User s Manual 11 04 2008 Author Christian Klemke Rev 02 If you choose to apply the detected configuration by clicking the corresponding button you get a short information about the changes CAT will apply
10. Project IRMA CAN Address Tool Content User s Manual 11 04 2008 Author Christian Klemke Rev 02 User s Manual Configuration Tool for IRMA DIST4 Sensors IRMA CAN Address Tool V3 0 6 49 Important note IRMA CAN Address Tool 3 x has to be used for configuration of IRMA DIST4 08 sensors Usage of older versions may cause sensor malfunction due to loss of important configuration data Document status 00 10 16 08 Initial draft 01 10 27 08 Modifications by Bernd Schubert and Andreas Wermke 02 11 04 08 Table in appendix A Wrong term iris part number replaced by right term iris product name CAN Address Tool 3 x Manual Rev 02 doc Ay Project IRMA CAN Address Tool Content User s Manual 11 04 2008 Author Christian Klemke Rev 02 Table of contents E O 3 2 Requirements ana EIMON urraca 3 3 Opera ON MOUE S A A am tantiat hans a Nase iaettee 4 4 Application Start and terminada ii iii 4 5 TSU IA WIN OO Wald 5 Bal User nenie tU cUTO an e AAA ASA A 5 5 2 GAN communication stan and device SEM a e 6 5 3 SENSO Cone Ura OT OVEIV SW A AS 6 DA Erordaetecion auna device Criada lcd 7 00 ADO AOS di lb 8 A A NO 8 A NN n ORAR 8 zo JENADI SOUN As 8 57 oleo mat AAA A ao R A EE ERRi 9 57 me how 02S gt 9 er nT TS REST ciicia 9 57 2 SNOW AZ IC System Contursi 9 5 7 2 1 Configuration readout via Service interface ooccooccncocncnocnonocnnnononcnnncononononarnonccnanonnncnanonos 10 AS NA
11. ally missing fields are all filled with their correct values A IRMA CAN Address Tool Stop CAN Commun List of connected sensors 11_00551 1 0x01 DIST4 02 Master 500 kBit s NIA 11_00553 2 0x02 DIST4 02 Master 500 kBit s NIA 13_01769 5 0x05 DIST4 08 Master 500 kBit s Gray Co Em 13_01770 6 0x06 DIST4 08 Master 500 kBit s Gray Co Em Check Configure Set System System System CAN Speed A enable Analyzer 23_0676 0x5C 244 is present in system CAN Address Tool 3 x Manual Rev 02 doc 6 17 Project IRMA CAN Address Tool Content User s Manual 11 04 2008 Author Christian Klemke Rev 02 Note as you can see in the screenshot the presence of an analyzer in the system which is usually the case is optionally indicated in button area right to the Show A21C System Cfg button You can select the Show Details option to get more detailed information like the firmware name The font size will be decreased and the list will look like this A IRMA CAN Address Tool Commun List Stop CAN f l Refresh List of connected sensors SerialNo Address Type M S CAN Speed Status HR Mode Software EPROM Config Hv 11_00551 1 0x01 DIST4 02 Master SOOKBit s Vaid N A N A can_4d26 M950xx 4kBit 1 02 N A Ga 11_00553 2 0x02 DIST4 02 Master SOOKBit s Vaid N A N A can_4d26 M950xk 4kBit 1 02 N A Ga 13 01769 5 0x05 DIST4 08 Master 500kBit s Vaid A GrayCoHEm atm08 ATMEL 16kKBk 201 3 Sa 130177
12. ers you three options to go on Confirmation gt Please select e Yes if you want to use the serial interface see 5 7 2 1 for details e No if you want to select the desired configuration manually e Cancel to abort the configuration process When you select manual configuration the configuration window appears and lets you specifiy the number of doors and each doors type thus its number of sensors by selecting the proper radio button Door Count and combo boxes Door Types CAN Address Tool 3 x Manual Rev 02 doc 10 17 Project IRMA CAN Address Tool Content User s Manual 11 04 2008 Author Christian Klemke Rev 02 Identify Sensors and Configure System Door Count gt r Door Types Sensor Assignments 1Doo AH Nanw i Senso y C 2Doos 882 Extra Wide 3 Sensors v 3Doos 183 Wide 2Sensors y 4Doors Not 5 Doors C 6 Doors 7 Doors 8 Doors The presentation is similar to the Show A21C System Configuration function described in section 5 7 2 including the coloring Once you are done click the Start Detection button to start the detection and configuration process Please note that the number of connected sensors is always known to CAT the application will therefore check your desired configuration against the actual hardware found on the CAN bus If there is a mismatch you get an error message The
13. heck System You can use CAT to check whether the current configuration contains potential or obvious problems Click the Check System button to run the check The result is presented in an appearing window If everything is ok you get the following message Perform System Check List of warnings and errors detected during system check Final result 7 Everything is okay no errors and or warnings were found Y Close This Window If something is wrong or seems suspicious CAT will inform you like this Perform System Check List of warnings and errors detected during system check The total number of detected sensors 4 does not match with the total number in the 421C L configuration 3 The 421C L configuration refers to sensor 3 0x03 but none of the connected sensors has that address Sensor 5 0x05 is present on the bus but it is not referenced by the current 421 CE L configuration Sensor 6 0x06 is present on the bus but it is not referenced by the current 421C L configuration Final result R There are problems errors and or warnings were found Y Close This Window The checks include e Consistent baud rate setting e Correct number of sensors with respect to the analyzer configuration e Correct sensor addresses with respect to the analyzer configuration e Consistent height ranges and operation modes e etc 5 7 2 Show A21C System Configuration To get an overview of your analyzer firmware parame
14. itial programming of newly assembled sensors i e Automatic mode this mode offers remote control of the programming process when integrating the application into production workflow This manual only describes the default mode which is limited in functionality but fully sufficient for common maintenance tasks customers are capable of doing themselves In this mode the user cannot change any internal settings like correction parameters etc manually The complete configuration is determined by the analyzer firmware and firmware parameters and the sensor assignment and programming happens in the so called semi automatic mode Extended production and automatic mode are meant for iris internal use and described in a separate document 4 Application start and termination The file name of the CAN Address Tool application is IrmaCanAddressTool exe Depending on your installation you may find it in your IRMA A21 Windows installation directory or somewhere outside In the first case you usually find an entry in the Start menu whereas in the second case you need do start the application by double clicking its icon IrmaCanAddressTool exe mS ar E a A LA Adoress To exit the application you simply need to click the main window s close button X on the upper right corner Important note If you have installed the software manually you need to ensure that the correct version of the file called CANUusb dll is
15. l Rev 02 doc 17 17
16. number of attached sensors does not match with the analyzer configuration The current configuration requires 6 sensors but 3 sensor s have been detected You need to correct this mismatch before the configuration Function can be used The same holds true if CAT got the confirmation data from the analyzer via CAN or serial service port Now let s presume that your configuration is valid In case of three sensors it will probably look similar to this Identify Sensors and Configure System Door Count r Door Types Sensor Assignments C 1Doo AH Nattaw i Sensor y 2Doos 82 Widel2Sensore y C 3Doors Not In Use C 4 Doors C 5Doors C 6Doors C 7 Doors C 8Doors Apply This Configuration Leave Configuration Untouched Please note that CAT shows the currently assigned sensor device numbers if their logical addresses match the analyzer firmware parameters CAN Address Tool 3 x Manual Rev 02 doc 11 17 Project IRMA CAN Address Tool Content User s Manual 11 04 2008 Author Christian Klemke Rev 02 Hitting the Start Detection button then initiates the detection There is a short initialization phase CAT tells you about blinking message Identify Sensors and Configure System B Initializing sensors Start Stop Detection Detection Door Count gt r Door Types Sensor Assignments C 1Doo AH Nattaw i Senso y 2Doos 2 Wide 2Sens
17. ors y C 3 Doors Not In Use C 4Doors 5 Doors C 6 Doors C 7 Doors 8 Doors oe Apply This Configuration 7 Leave Configuration Untouched Shortly thereafter the CAT starts giving you instructions and status messages blinking on the windows top area Identify Sensors and Configure System B Please cover sensor 1 of 1 at door 1 Start Detection i Door Count gt r Door Types Sensor Assignments C 1Doo AH Nattaw i Senso y 2Doos M2 Wide 2Sensors y C 3Doors Not In Use C 4Doors 5 Doors C 6 Doors C 7 Doors 8 Doors Apply This Configuration MY Leave Configuration Untouched CAT analyzes the distance data sent by the connected sensors to identify the one you are currently covering Please follow the given instructions In this case go to sensor number 1 at the first door and cover it Covering is best done by holding a piece of white paper in a distance of about 25 cm 10 inches centered below the sensor As you can see CAT detects the changed distance information and asks you to hold position for a few seconds CAN Address Tool 3 x Manual Rev 02 doc 12 17 Project IRMA CAN Address Tool Content User s Manual 11 04 2008 Author Christian Klemke Rev 02 Identify Sensors and Configure System Please cover sensor 1 of 1 at door 1 Door Count Door Types Sensor Assignments 1 Door Ce
18. stendstr 1 14 12459 Berlin Germany Phone 49 30 53073 840 Fax 831 mail irisgmbh de www irisambh de intelligent This software contains modified and unmodified graphics taken from the Tango Desktop Project see tango freedesktop org the Wikimedia Commons library see commons wikimedia org the German Wikipedia encyclopedia see de wikipedia org The cat face in the splash screen background is based on an internet photography by Lisa Nielsen iris infrared amp 5 6 Further Options 5 6 1 Event Log By toggling the Show Event Log checkbox in the options bar you can show and hide an event log window It may contain helpful information when experiencing problems Event Log List of events 11 03 55 359 Recognized new sensor 13_01770 Ox346E4 11 03 55 359 Recognized new sensor 13_01769 0x346E 9 11 03 55 359 Recognized new sensor 11_00553 0x20229 11 03 55 359 Recognized new sensor 11_00551 Dx20227 11 03 55 093 Scanning started at 500 kBit s 5 6 2 Enable Sounds CAN Address Tool 3 x Manual Rev 02 doc 8 17 Project IRMA CAN Address Tool Content User s Manual 11 04 2008 Author Christian Klemke Rev 02 Optionally some events trigger a matching sound output e g detection of sensor attachment and detachment You can control this feature by selecting deselecting the Enable Sounds option Disabling sounds usually speed up the detection process 5 7 Configuration buttons 5 7 1 C
19. ters you can click Show A21C System Cfg CAT will show you the function areas doors along with the expected number of sensors and their addresses For your convenience each function area is highlighted with a different color CAN Address Tool 3 x Manual Rev 02 doc 9 17 Project IRMA CAN Address Tool Content User s Manual 11 04 2008 Author Christian Klemke Rev 02 Show Current A21C L Configuration Door Count Door Types Sensor Assignments 1Door Hat Nanom TSensod 2Door H2 Wide 2Sensors C 3 Doors 3 NotInUse C 4Doors 4 Not In Use 5 Doors 5 NotinUse C 6 Doors 6 ln tin U C 7 Doors 7 N t In Use C 8 Doors Ha IN Ise 5 7 2 1 Configuration readout via service interface In case the analyzer is not visible on the CAN bus CAT offers a configuration readout via the RS232 service interface A dialog is shown to tell CAT about the connection parameters Please select whatever applies to your system and click OK to start the readout process Configure Service Port Operation COM Port Default Protocol Speed IRMA Address com J1708 After successful readout the configuration is shown the same way as shown above 5 7 3 Configure System In order to use the semi automatic configuration capabilities of CAT please click the Configure System button Usually the analyzer is visible in the system and CAT automatically retrieves its firmware parameters using CAN communication If it isn t CAT off
20. the iris web site though The CAN Address Tool tries to be compatible with the widest range of hard and software versions possible However some of the features that are available today might not be supported by older hard and or software The CAN Address Tool tries to identify such deficiencies when used with existing software providing proper warning messages to the user and disabling some functions if necessary Please note that the official minimum supported firmware revision for the DIST4 sensor is can 4d28 atm 08 respectively However work with former releases is supported but it is strongly recommenced to use a special power only CAN cable and not to attach multiple sensors at the same time Therefore when the CAN Address Tool detects at least one sensor with a less up to date software revision a proper warning message is displayed to the user In a nutshell the requirements are as follows e The analyzer firmware needs to support the so called muzzle command which immediately stops any unsolicited communication on the CAN bus This feature is provided by any firmware which has IRMA Opera version gt 2 99f e The same goes for the sensor firmware Additionally the sensor firmware has to provide a way to temporarily switch to the so called physical addressing mode Furthermore is recommended that the firmware has a protection mechanism to prevent accidental modification of E7PROM data All
21. this is guaranteed by sensor firmware can 4d28 atm 08 or newer e As of now the CAN Address Tool is only available with an English user interface Localized versions are currently not planned e Of course a CANusb converter needs to be connected and its driver software needs to be correctly installed When uses with old sensors and or analyzers a special CAN adapter http www irisgmbh de iris GmbH _ technische dokumente service software index html see Appendix B gt see Appendix A or official iris cable catalogue see Appendix B gt External hardware interface made by softing AG and available from iris as well see Appendix A CAN Address Tool 3 x Manual Rev 02 doc 3 17 Project IRMA CAN Address Tool Content User s Manual 11 04 2008 Author Christian Klemke Rev 02 cable with disconnected communication lines is necessary Please refer to the official CAN cable catalogue e Last but not least it should be mentioned that this document refers to the IRMA CAN Address Tool V3 0 6 49 or newer 3 Operation modes The improved CAN Address Tool supports four basic operation modes each of them covering their own field of use e Default mode basic functionality for end users see below e Extended mode this mode is meant to be used by specially trained users and iris people e Production mode this feature has been implemented to provide a fast and efficient way to do the in
22. ts the Following problems Configuration error or EEPROM read error Checksum error This is most probably caused by use of IRMA CAN Address Tool older than 3 0 x with this sensor which unfortunately may have resulted in deletion of some vital sensor data Please contact iris support to discuss how to solve the issue Once the sensor list is filled you have the following options to go on e Let CAT verify the current configuration e Re configure the whole system in terms of address assignments and master slave modes e Change the baud rate setting for all sensors e Simply show the configuration expected by the attached A21C analyzer All these functions are activated by clicking the corresponding buttons in the action area They are described in sections 5 7 Note As you can see there are several additional action buttons on the right side which are disabled These actions are reserved for use by iris staff and or trained service partners 5 5 About dialog By clicking on the About link on the bottom right of the main window you can display a message box containing the detailed software version number along with copyright notices This information might be asked by iris staff to handle support requests About IRMA CAN Address Tool SS IRMA CAN Address Tool Version 3 0 6 49 built on 2008 09 18 Copyright 2004 08 by iris GmbH Berlin All rights reserved sensor iis GmbH infrared amp intelligent sensors O
Download Pdf Manuals
Related Search
Related Contents
RH Sway Control Instructions Unifier User Guide - Facilities Management Raviv`lak Sony STR-DE875 User's Manual NAD Electronics HTR-5 User's Manual Mode d`emploi pour créer votre compte pour l`accès à l`outil de Model T100, T120, T140, LO 140-200 Instrucciones de instalación y mantenimiento Copyright © All rights reserved.