1. 300 mm Headrest Slide Stroke 170 mm Leonest SB STOKO reanna 230 mm Power C OBSUITIDEIOH 230V 50Hz 3 7A 695 After Ser No DCQ080177 2 3 DOCTOR UNIT SECTION BASE MOUNT TYPE CART TYPE 3 OPERATING AND ADJUSTMENT INSTRUCTIONS 3 1 Master Switch Section MASTER SWITCH bo d ON OFF POWER INDICATOR Fig 3 1 Master Switch and Power Indicator 1 Master Switch Fig 3 1 Master switch is located at right side rear under the doctor table Master switch turns the air water and electric power ON OFF at the utility section When master switch is off air and water are shut off at hard pipings in the utility section It is always recommended to turn off master switch when closing the office 2 Power Indicator Fig 3 1 Power indicator is located at centre of doctor table main control panel When the master switch 1s ON position a green L E D illuminates Note Before operation turn on the main switch for chair Ref 3 6 1 A Main Switch for Chair 3 2 Cuspidor Unit Section 1 Cuspidor Section Control Panel Fig 3 2 Cuspidor section control panel is located inside of cuspidor unit body O 1 A Water Heater Switch Fig 3 2 Water heater switch allows warm water for cupfiller l l Fig 3 2 Cuspido
2. They can be controlled by the doctor unit section and foot control 4 A Electric Motor Power Control Knob Option Electric motor rotation speed can be controlled by electric motor power control knob Fig 3 9 Control Knobs and Switchs Turning electric motor power control knob to clockwise for Optinal Equipment increases rotation speed and turning tocounter clockwise decreases rotation speed 4 B Scaler Power Control Knob Option Scaler power can be controlled by scaler power control kob Turning scaler power control knob to clockwise increases scaler power and turning to counter clockwise decreases scaler power 4 C Electric Motor Forward Reverse Rotation Switch Option To turn electric motor forward reverse rotation switch to facing right side electric motor rotates forward and to turn to facing left side electric motor rotates reverse NCAUTION Handpiece Refer to handpiece manufacturers operating instructions Fa 5 Handpiece Holder Angle Fig 3 10 Handpiece holder angle can be adjusted by loosing M4 set screw at facing left hand side under the handpiece holder arm After adjustment retighten M4 set screw Handpiece holder angle can not be adjusted individually Fig 3 10 Handpiece Holder Angle Adjustment Set Screw 6 Lock Knob for Doctor Table Height Adjustment Fig 3 11 While supporting the doctor table by a hand loosen lock knob to counter clockwise and doctor table will go up and down fr
3. equipment Chair preset1 To Recline the backrest Chair manual control Micro motor rotation speed control Service outlet water Air Manufacturer Chair preset2 To lower the chair Film viewer on off Micro motor Forward Reverse select Bowl flush Service outlet air Type B Applied Parts Date of manufacture 1 OVERALL VIEW AND MAJOR COMPORNENTS 42 43 0 9 40 CHAIR SECTION DOCTOR UNIT SECTION Chair 23 Doctor Table 2 Headrest 24 Doctor Table Main Control Panel 3 Backrest 25 Dental Viewer 4 Seat 26 Doctor Tray 5 Legrest 27 Waste Receptacle 6 Footrest 28 Handpiece Holder 7 Armrests 29 Handpieces 8 Backrest Rear Cover Micromotor Air Turbine Motor 9 Base Cover Scaler and etc Manufacturers recommend 10 Power Supply Panel to use the handpieces with CE markings 11 Doctor Table Arm 12 Chair Preset Panel FOOT CONTROL SECTION 13 Stick Switch Manual Mode 30 Foot Control CUSPIDOR UNIT SECTION 14 Cuspidor Unit LIGHT POST SECTION 15 Cupfiller Nozzle 31 Light Post 16 Bowl Flush Nozzle 32 Light Pole 17 Cuspidor Bowl 18 Assistant Side Control Panel 19 Saliva Ejector 20 3 way Syringe 21 High Volume Evacuator 22 Assistant Holder 2 DIMENSIONS AND SPECIFICATIONS 2 1 CHAIR SECTION 452 1690 Le N ES C 90 To 5 a a 1 L 530 480 680 EIE TO BE E 487 mm Seat Elevation Stroke
4. After cleaning the handpieces apply a white vaseline lightly on the rubber parts O Ring and screws parts for long life Keep the handpieces in a clean place 2 Micro Motor Air Motor Turbine Scaler Sterilize the handpiece according to manufacturer s operating manual 3 Belmont 77 Syringe Fig 4 3 A Remove the nozzle from syringe and clean it Sterilization A Wash off dirt of the handpiece with natural detergent B Rinse the handpiecwe with tap water C Insert the handpiece in a sterilization pouch and seal it D Autoclave for 20 min at 121 C NCAUTION Fig 4 3 H V E and S E Handpiece Skip dry cycle Keep the syringe in a clean place 4 Tubing and Hose It is recommended that Durr FD333 be used to clean the exterior parts of tubing and hose debi 4 4 Drain Valve for Air Filter in Utility Section Fig 4 4 Open the drain valve once a week to drain off the water from the air filter in utility section 4 5 Vinyl leather of chair Wipe the vinyl leather with soft cloth using upholstery cleaner 4 6 Master Switch After the daily operation and maintenance turn off the Fig 4 4 Utility Section master switch under the doctor table Ref 3 1 Master Switch Section 15 S ELECTROMAGNETIC COMPATIBILITY EMC Medical electrical equipment needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided in this manual Portable and mobi
5. Temperature Operating 5 40 Storage 10 50 Humidity 10 80 Atmospherical Pressure 600 hPa 1060 hPa Compatibility of Handpieces Use the compatible handpieces as shown on the attached list for this unit List of compatible handpieces Important Notes In case of the troubles please contat Takara Belmont offices or your dealers Do not disassemble or attempt to repair Disassembly repair or modifications shoud only be done by a qualified repair technician Attempts at disassembly repair or modifications may lead to abnormal operation and accidents In case of disposal of equipment When disposing the chair appropriately dispose complying with all current applicable regulations and local codes In EU area EU directive 2002 96 EC on waste electrical and electronic equipment WEEE is applied on this product In this directive environment conscious recycling abandonment is obligated SYMBOLS Chair last position Chair auto control To raise the backrest Fiber optic handpiece light on off 7 Handpiece coolant spray on off LI M Cupfiller Non ionizing 6 radiation Caution It means caution AN warnings or possibility to danger Chair auto return To raise the chair Chair manual control Scaler power control Syringe Service outlet water flow control Authorized representative in the European community Separate collection for electrical and electronic
6. equipment d and the SP CLEO as recommended below according to the maximum output power of the communications equipmen Separation distance to onc of transmitter Rated maximum output power al 150 kHz 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz 12 1 2 d 2 3 3 3 For transmitters rated at a maximum output power not listed above the recommended separation distance d in metres m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1 At 80 MHz and 800MHZz the separation distance for the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by adsorption and reflection from structures objects and people 18 6 LIST OF COMPATIBLE HANDPIECES 19 NOTE ewe Takara Belmont UK Ltd Belmont House E TAKARA BELMONT CORPORATION 2 1 1 Higashishinsaibashi Chuo ku Osaka 542 0083 Japan TEL 81 6 6213 5945 FAX 81 6 6212 3680 One St Andrews Way Bow London U K Tel 44 20 7515 0333 HOO NO AE Ones Fax 44 20 7987 3596 Printed in Japan 1110 ul
7. 0 54 Mpa 5 0 5 5 kg cm already adjusted at factory Max 0 49 Mpa 5 0 kg cm 2 Water Pressure More than 0 1 Mpa 1 0 kg cm water pressure at the regulator in the utility section is requested for operating this unit efficiently Adjust the water regulator in the utility section at 0 1 0 19 Mpa 1 0 2 0 kg cm Already adjusted at factory Max 0 19 Mpa 2 0 kg em Note In case of water saliva ejector high water pressure supplies efficient suction power 3 5 Foot Control Section Fig 3 16 1 Drive Air Pedal Handpiece speed can be controlled by drive air pedal 2 Coolant Water ON OFF Switch Coolant water ON OFF switch allows for coolant water to be turned on or off without disturbing flow adjustment 3 Chip Blower Button By treading chip blower button on chip blower comes out from handpiece without bur turning 3 6 Chair Section 1 Chair Power Supply Panel Fig 3 17 Chair power supply panel is located on sitting right hand side chair base 1 A Main Switch for Chair Main switch for chair turns electric power ON OFF Neon lamp in the main switch illuminates in green when chair and unit electric power is ON 1 B Fuse Holder and Fuse An over current protection device rated for 6 3A 230 type DECREASE INCREASE PRESSURE 7 WATER PRESSURE GAUGE AIR PRESSURE GAUGE 11 DECREASE INCREASE I PRESSURE PRESSURE Fig 3 15 Utility Section CHIP BLOWER BUTTON DRIVE AIR P
8. DENTAL UNIT AND CHAIR OPERATING INSTRUCTIONS IMPORTANT This manual provides operating instructions for SP CLEO The instructions contained in this booklet should be thoroughly read and understood before operating the unit and chair File this manual and refer back to it for future maintenance E emot TABLE OF CONTENTS I OVERALL VIEW AND MAJOR COMPORNENTS 2 DIMENSIONS AND SPECIFICATIONS 2 1 Chair Section 2 2 Cuspidor Unit Section 2 3 Doctor Unit Section 3 OPERATING AND ADJUSTMENT INSTRUCTIONS 3 1 Master Switch Section 3 2 Cuspidor Unit Section 3 3 Doctor Unit Section 3 4 Utility Section 3 5 Foot Control Section 3 6 Chair Section 4 DAILY MAINTENANCE 5 ELECTROMAGNETIC COMPATIBILITY 6 LIST OF COMPATIBLE HANDPIECES Intended Use of the Product This product is an active therapeutic device intended for the exclusive use for diagnoses treatments and relative procedures of dentistry The product must be operated or handled by the qualified dentists or by dental staffs under the supervision of the dentist Such dentists or dental staffs should instruct and or assist the patients to approach to and leave from the product Patients should not be allowed to operate or handle the product unless he she is so instructed The product is supplied together with the handpieces like electric micromotor air turbine and or motor scaler and so on Environmental Requirements Ambient
9. EDAL COOLANT WATER ON OFF SWITCH DRIVE AIR PEDAL Fig 3 16 Foot Control FUSE HOLDER MAIN SWITCH Fig 3 17 Chair Power Supply Panel AUTO POSITIONING MANUAL CONTROL SWITCHES SWITCHES Fig 3 18 Doctor Table Main Control Panel 2 Chair Manual Control Switches Fig 3 18 Fig 3 19 Chair manual control switches are located on the doctor table main control panel and the sitting right hand side base cover Stick Switch lt lt 2 A Seat Height Adjustment e Me To Raise press f button on main control panel or move up stick switch To Lower press J button on main control panel or move down stick switch 2 B Backrest Angle Adjustment Raise press 7 button on main control panel or move right stick switch Fig 3 19 Stick Swich To Recline press button on main control panel or move left stick switch STICK SWITCH 3 Chair Auto Positioning Switches Fig 3 18 Fig 3 20 Chair auto positioning switches are located on the doctor table main control panel and the assistant side control panel 3 A Preset Operation This chair has two preset positions Preset 1 and Preset 2 Momentarily press 1 button on main control panel or assistant side control panel chair will move to preset 1 position automatically Preset 2 1s operated by 2 button 3 B Auto return Operation Momentarily press 0 button on main control panel or assistant side control pane
10. al environment NOTE 0 15 the a c mains voltage prior to applications of the test level 16 Guidance and manufacture s declaration electromagnetic immunit The SP CLEO is intended for use in the electromagnetic environment specified below The customer or the user of the SP CLEO should assure that it is used in such an environment Immunity test IEC 60601 test level ir m Electromagnetic environment guidance Portable and mobile RF communications equip ment should be used no closer to any part of the SP CLEO including cables than the recommended separation distance calculated from the equation applications to the Frequency of the transmitter Recommended separation distance Conducted RF 3 Vrms d 12 IEC 61000 4 6 150 kHz to 80 MHz outside ISM bands Radiated RF 3V m d 1 2VP 80 MHz to 800 MHz IEC 61000 4 3 80 MHz to 2 5 GHz d 2 3VP 800 MHz to 2 5 GHz Where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer and d is the recommended separation distance in metres m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey should be less than the compliance level in each frequency range Interference may occur in the vicinity of equipment marked with the following symbol a NOTE 1 At 80 MHz and 800MHZ the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagn
11. d as last position memory operation 1 Set backrest in the desired position by manual control switches 2 Keep depressing LP button on doctor table or assistant side control panel until buzzer sounds so that the position is memorized to mouth rinsing position then the buzzer sound ceases 2 12 4 CARE AND MAINTENANCE NCAUTION Turn off the master switch at the initial position after daily operation or in long term interval Turn off the main water valve after daily operation or in long term interval 4 1 Care and maintenance for chair 4 1 Other than cleaning no scheduled maintenance of chair is required NCAUTION Do not drench the chair for cleaning Do not use polishing powder solvents strong disinfectant and hot water for cleaning After cleaning wipe with a dry soft cloth and keep dry Upholstery can be cleaned with a neutral detergent Paint parts metal parts and plastic parts can be cleaned with DURR FD333 cleaner or equivalent Do not drench the chair and unit Wipe all surfaces dry after cleaning 4 2 Care and maintenance for unit 4 2 Cleaning unit NCAUTION Do not drench the unit for cleaning Do not use polishing powder solvents strong disinfectant and hot water for cleaning After cleaning wipe with a dry soft cloth and keep dry All surfaces can be cleaned with DURR FD333 cleaner or equivalent Spray the cleaner DURR FD333 on cloth and wipe the surfaces with the c
12. d be wood concrete or discharge ESD 8 kV air 8 kV air ceramic file If floors are covered IEC 61000 4 2 with synthetic material the relative humidity should be at least 3096 Electrical fast 2 kV for power 2 kV for power Mains power quality should be that transient burst supply lines supply lines of a typical commercial or hospital IEC 61000 4 4 1 kV for input output 1 kV for input output environment lines lines Surge 1 kV differential mode kV differential mode Mains power quality should be that IEC 61000 4 5 2 kV common mode 2 kV common mode of a typical commercial or hospital environment Voltage dips short lt 5 U lt 5 Mains power quality should be that interruptions and 295 dip in 07 295 dip in 07 of a typical commercial or hospital voltage variations for 0 5 cycle for 0 5 cycle environment If the user of the SP on power supply 40 Ur 40 Ur CLEO requires continued operation input lines 60 dip in Uy 60 dip in Uy during power mains interruptions it IEC 61000 4 11 for 5 cycle for 5 cycle is recommended that the SP CLEO 70 Ur 70 Ur be powered from an uninterruptible 30 dip in Uy 30 dip in Uy power supply or a battery for 25cycle for 25cycle lt 5 Ur lt 5 Ur 295 dip in U 295 dip in U for 5 5 for 5 s Power frequency Power frequency magnetic fields 50 60 Hz should be at levels characteristic magnetic field of a typical location in a typical IEC 61000 4 8 commercial or hospit
13. eely Adjust the height of doctor table and then tighten lock knob firmly oN Base Mount Type Cart Type Fig 3 11 Lock Knob A VIEW LEVEL ADJUSTMENT 7 Level Adjustment Screws for Doctor Table Fig 3 12 Level of the doctor table can be adjusted by PAN screwing unscrewing four set screws located NW in the doctor table Remove the table top and adjust the level by T SCREWS screwing unscrewing the four set screws level adjustment screws A VIEW LEVEL ADJUSTMENT SE Retighten the four set screws firmly Fig 3 12 Level Adjustment Screws 8 Friction Adjustment set screw of table rotation Fig 3 13 Friction of table rotation can be adjusted by the set screw located in table rotation flange under the table 9 Friction Adjustment Nut of Horizontal Arm Fig 3 14 FRICTION ADJUSTMENT Friction of horizontal arm can be adjusted by SET SCREW ine th l h f the hori l T turning the nut located at the end of the horizontal arm Fig 3 13 Table Rotation Friction Adjustment Set Screw FRICTION ADJUSTMENT NUT Tighten Loosen A VIEW A VIEW Fig 3 14 Friction adjustment of Horizontal Arm 3 4 Utility Section Fig 3 15 1 Air Pressure Regulate the output air pressure of compressor to the utility section at 0 54 0 59 Mpa 5 5 6 0 kg cm and air flow volume 15 at least 55 Nl min 88 Nl min in case of air vacuum type Adjust the air regulator in the utility section at 0 49
14. etic propagation is affected by adsorption and reflection from structures objects and people Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the SP CLEO is used exceeds the applicable RF compliance level above the SP CLEO should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as reorienting or relocating the SP CLEO Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3V m Essential performance purpose of IMMUNITY testing Unless operated by the switches for chair control the chair section of the SP CLEO does not make any movements except for sounding a buzzer and switching on off the indicator 17 Recommended separation distances between Portable and mobile RF communications equipment and the SP CLEO The SP CLEO is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the SP CLEO can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications
15. l chair will return to the initial position Seat Is fully lowered and backrest is upright position with footrest retracted SWITCHES Note Footrest section operation can be controlled by only Fig 5 20 Assistant side Control Panel auto positioning mode 3 C Last Position Memory Operation Momentarily press LP button at reclined backrest position treatment position and backrest will raise to mouth rinsing position Press momentarily LP button again backrest will recline to previous treatment position Note Seat height can not be changed by LP button 105 4 Headrest 4 A Standard Type Headrest Fig 3 21 Height Adjustment Press down or pull up headrest to the position required Angle Adjustment Push the headrest forward as required Lift the headrest lever to rotate the headrest backward 4 B Twin Axis Type Headrest Option Fig 3 22 Fig 3 21 Standard Type Head Height Adjustment Press down or pull up headrest to the position required Angle Adjustment Holding the headrest cushion grip the headrest release button and headrest can be moved freely Adjust the headrest to suitable position and release headrest release button 5 Armrest Rotation Fig 3 23 Sitting right hand side armrest can be rotated by pulling outward 6 Auto Positioning Mode Cancell System Automatic movement in all auto positioning mode Preset 1 Preset 2 Auto return and Last position memory can be instantly ca
16. le RF communications equipment can affect medical electrical equipment The equipment or system should not be used adjacent to or stacked with other equipment If adjacent or stacked use is necessary the equipment or system should be observed to verify normal operation in the configuration in which it will be used Guidance and manufacture s declaration electromagnetic emissions The SP CLEO is intended for use in the electromagnetic environment specified below The customer or the user of the SP CLEO should assure that it is used in such an environment RF emissions The SP CLEO uses RF energy only for its internal function CISPR 11 Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment The SP CLEO is suitable for use in all establishments CISPR 11 including domestic establishments and those directly connected to the public low voltage power supply network IEC 61000 3 2 that supplies buildings used for domestic purposes Voltage fluctuations Flicker emissions Complies IEC 61000 3 3 Guidance and manufacture s declaration electromagnetic immunity The SP CLEO is intended for use in the electromagnetic environment specified below The customer or the user of the SP CLEO should assure that it is used in such an environment IEC 60601 Electromagnetic environment Immunity test Compliance level test level guidance Electrostatic 6 kV contact 6 kV contact Floors shoul
17. loth Do not drench the chair and unit Wipe all surfaces dry after cleaning BASCKET STRAINER 22 4 1 Basket Strainer Fig 4 1 Take out the basket strainer in centre of cuspidor Wr bowl and clean it 4 2 Solid Collector Fig 4 1 Open the side panel of the cuspidor body and take out solid collector container and filter and clean them A ar d V CS SOLID COLLECTOR FILTER 2 SOLID COLLECTOR CONTAINER Fig 4 1 Cuspidor Bowl 13 4 3 Handpieces 1 Vacuum Handpiece and Saliva Ejector Fig 4 2 A Pull and remove the top parts of each handpiece and clean strainer l V Ti B After daily operation run two cup of clean water a Saliva Ejector n Tip through the handpieces to clean inside Sterilization Saliva Ejector Vacuum Cap Vacuum Tip Saliva Ejector Tip Vacuum Cap Vacuum f Handpiece Body Saliva Ejector Handpiece Body canbe Vacuum Handpiece P eee Body sterilized with autoclave Vacuum handpiece body and saliva ejector body must Slide M Slide Knob be assembled before autoclaving 26 l l Saliva Ejector A Wash off dirt of the handpiece with natural detergent Hose Hose B Rinse the handpiecwe with tap water C Insert the handpiece in a sterilization pouch and Fig 4 2 H V E and S E Hand seal it piece D Autoclave for 20 min at 121 C Note The slide knob can be autoclaved 100 times and is an expendable supply NCAUTION Skip dry cycle Note
18. ncelled at any time by momentarily depressing any chair control switch 7 Chair Safety Lock System The SP CLEO equips chair safety device to prevent from accidental crash or damage 7 A Handpiece Chair Safety Lock System During runinig handpiece chair safety lock system is working and the chair can not be operated by any switch 7 B Doctor Table First Arm Chair Safety Lock System Fig 3 24 When doctor table first arm is turned to clockwise about 30 degree into backrest side chair safety lock system is working and the chair can not be operated by any switch 7 C Doctor Table Lift Chair Safety Lock System When the doctor table is lifted up chair safety lock system is working and the chair can not be Fig 3 24 Doctor Table First Arm operated by any switch Chair Safety Lock System Note When chair safety lock system is working LOCK OFF L E D on the chair preset panel will be turned off Fig 3 25 zi 8 Preset Position Adjustment Fig 3 25 STORE Fig 3 25 Chair Preset Panel 1 Set seat and backrest in the desired position by manual control switches 2 Keep depressing 1 button on doctor table or assistant side control panel until buzzer sounds so that the position is memorized to PRESET 1 then the buzzer sound ceases 3 PRESET 2 is memorized by pressing 2 button as following 1 to 2 9 Mouth Rinsing Backrest Position Adjustment Fig 3 25 The desired mouth rinsing backrest position can be programme
19. ockwise decreases 3 Handpiece Drive Air and Coolant Air Adjustment Screws Fig 3 7 Fig 3 8 Loosen 4 screws from the table bottom and open the table top Auto select valve and handpiece pressure gauge are located in the table Caution Please remove the table top carefully because the table top is connected with wires behind the table top 3 L Handpiece Drive Air Adjustment Screw Fig 3 8 Adjustment of drive air to each handpiece can be made by the screw on the auto select valve It is important to set the drive air pressure in accordance to the handpiece manufacture s recommendation Setting The Optimum Condition Turn the appropriate dive air screw fully clockwise depress drive air pedal of foot control to fully open maximum foot pressure and turn the adjustment screw slowly in counter clockwise direction Stop turning the screw immediately when handpiece pressure gauge shows the desired drive air pressure 3 M Handpiece Coolant Air Adjustment Screws Fig 3 8 Handpiece coolant air adjustment screws are provided for individual adjustment of handpiece coolant alr SYRINGE HOLDER STANDARD TYPE AUTO SELECT VALVE HP1 HP2 HP3 HP4 OPTION HP1 PRESSURE GAUGE HP3 A VIEW Fig 3 7 Fig 3 7 Doctor Table Inside IE oor 4 Control Knobs and Switches for Optional Euipment Fig 3 9 SP CLEO can be available fiber optic electric scaler and electric motor as factory option
20. r Section Control Panel 1 B Cupfiller Flow Control Valve Fig 3 2 Cupfiller flow control valve adjusts cupfiller to suitable flow volume 1 C Bowl Flush Flow Control Valve Fig 3 2 Bowl flush flow control valve adjusts bowl flush flow to optimum rinse action 1 0 Assistant side syringe flow control valves Fig 3 2 Assistant s syringe flow control valves adjust air and water to the assistant s syringe Yellow capped knob is air flow control valve blue capped knob is water flow control valve Note Turning flow control knob to counter clockwise increases flow volume and turning to clockwise decreases 2 Assistant Side Control Panel Fig 3 3 Assistant side control panel 1s located on the front side of cuspidor unit 2 E Cupfiller Switch Momentarily press the cupfiller switch and cup will be filled with water At the same time bowl flush water will flush out about 12 seconds and stop automatically 1 Water filling time is set for 5 seconds at factory Note Cupfiller water flow volume can be adjusted by cupfiller flow control valve Ref 3 2 Cuspidor Section 1 B 2 F Bowl Flush Switch Momentarily press the bowl flush switch and bowl flush water will flush continuously until H the bowl flush switch is pressed again Note Bowl flush water flow volume can be adjusted by bowl flush flow control valve Ref 3 2 Cuspidor Unit Section 1 C Fig 3 3 Assistant Side Control Panel 2 G Water O
21. utlet Water outlet provides quick connect water 2 H Control Knob for Water Outlet Water flow adjustment provides water flow towater outlet 2 I Assistant side Chair Auto Positioning Switches Ref 3 6 Chair Section 3 Assistant Side Instrument Holder Pick up the instrument Saliva Ejector or High Volume Evacuator from assistant holder it starts working automatically Return the H V E or S E handpiece to assistant holder it stops after about 8 seconds working Central vacuum type only 4 3 way Syringe By depressing either or both buttons syringe offers air water and spray Syringe tip can be rotated freely Syringe air water and spray can be adjusted by syringe flow control valve Ref 3 2 Cuspidor Section 1 D 5 Cupfiller Water Temperature Adjustment Fig 3 4 Cupfiller water temperature can be adjusted by water heater temperature adjustment screw TEMPERATURE Water heater is located in cuspidor body and its adjustment screw 15 located on top Turn to clockwise increase cupfiller water temperature and turn to counter clockwise decrease water temperature DRAIVER Note Confirm water temperature at any time after adjustment water heater Fig 3 4 Cupfiller Water Heater Temperature Adjustment 3 3 Doctor Unit Section 1 Doctor Table Main Control Panel Fig 3 5 Fig 3 5 Doctor Table Main Control Panel 1 A Dental Viewer Intraoral film can be mounted by a magnetic bar 1 B Dental Vie
22. wer Switch Momentarily pressing turns ON Off the viewer 1 C Light Pack Switch Option Momentarily press light pack switch fiber optic light power will be turned on untill light pack switch is pressed again 1 D Bowl Flush Switch Ref 3 2 Cuspidor Unit Section 2 1 E Cupfiller Switch Ref 3 2 Cuspidor Unit Section 2 F 1 F Doctor Side Chair Auto positioning Switches Ref 3 6 Chair Section 1 G Doctor Side Chair Manual Control Switches Ref 3 6 Chair Section 2 Control Knobs Fig 3 6 Handpiece coolant water and air adjustment knobs syringe flow adjustment knobs are located right hand side under the doctor table Fig 3 6 Doctor Unit Control Knobs 2 H Handpiece Coolant Water Adjustment Knobs For individual handpiece coolant water adjustment handpiece coolant water adjustment knobs are lined up from front side HPI HP2 HP3 The handpiece holder numbers are from facing left hand side HPI HP2 HP3 2 I Handpiece Coolant Air Adjustment Knob Handpiece coolant air adjustment knob controls the flow of coolant air to all handpieces 2 J Doctor Side Syringe Flow Adjustment Knobs Doctor side syringe flow adjustment knobs adjust air and water to doctor side syringe Yellow capped knob is air control knob blue capped knob is water control knob 2 K Master Switch Ref 3 1 Master Switch Section Note Turning flow control knob to counter clockwise increases flow volume and turning to cl