Operating Instructions - ACS-Control

image

Contents

1. Limit values limits L 7 Default 0200 Pen P For both limit values two different values can be parameterized With this the parameters for each limit value are called up one after the other ACS CONTROL SYSTEM GmbH Lauterbachstr 57 1D 84307 Eggenfelden Iwww acs controlsystem delinfo acs controlsystem de S Menu level Parameterization level Hysteresis for limit values H3 1 Default 0000 o g egege For both limit values a hysteresis function exists that reacts according to the functional principle operating current quiescent current Function if display falls below exceeds limit value FU Default HI9H 5 nN v v P To indicate if the value falls below the lower limit value LOUU can be selected LOW lower limit value and if it goes above the upper limit value HIGH can be selected HIGH upper limit value LOW corresponds to the quiescent current principle and HIGH to the operating current principle Limit value limits L 2 Default 0300 Paegegaet For both limit values two different values can be parameterized With this the parameters for each limit value are called up one after the other Hysteresis for limit values HY 2 Default 0000 2 g 8g e gae For both limit values a hyster
2. There are several measuring inputs options 0 60 mV or 0 150 mV signals as the works calibration without application of the sensor signal and SENS as the sensor calibration with the sensor applied Confirm the selection with P and the display switches back to menu level Setting the measuring range end value END Default 1900 Feglebeblas oe Set the end value from the smallest to the highest digit with A Y and confirm each digit with P A minus sign can only be parameterized on the highest value digit After the last digit the display switches back to the menu level If SENS was selected as the input option you can only select between NOCA and CAL With NOCA only the previously set display value is taken over and with CAL the device takes over both the display value and the analogue input value Setting the measuring range start offset value OFFS Default 0000 Sgepeglsds or Enter the start offset value from the smallest to the highest digit A Y and confirm each digit with P After the last digit the display switches back to the menu level If SENS was selected as the input option you can only select between NOCA and CAL With NOCA only the previously set display value is taken over and with CAL the device takes over both the display value and the analogue input value Setting the decimal point DOT Defaul
3. is only connected on one side or the input is open e Not all of the activated setpoints are parameterised Check if the relevant parameters are adjusted correctly The word HELP lights up in the The unit has found an error in the configuration 7 segment display memory Perform a reset to the default values and re configure the unit according to your application 4 Program numbers for parameterising e Programming lock is activated of the input are not accessible Enter correct code 5 ERRT lights up in the 7 segment e Please contact the manufacturer if errors of this display kind occur The device does not react as e If you are not sure if the device has been expected parameterised before then follow the steps as written in chapter 6 and set it back to its delivery status 1 6 ACS CONTROL SYSTEM GmbH Lauterbachstr 57 1D 84307 Eggenfelden l www acs controlsystem delinfo acs controlsystem de ACS CONTROL SYSTEM GmbH Lauterbachstr 571D 84307 Eggenfelden Iwww acs controlsystem delinfo acs controlsystem de 17 OHO a amp x fill level water level pressure temperature flow visualization signal converter sensoric Wir erwarten Ihren Anruf ACS CONTROL SYSTEM GmbH Lauterbachstr 57 D 84307 Eggenfelden Tel 49 0 8721 9668 0 ACS CONTROL SYSTEM rg OE info acs controlsystem de knowhow with system contsys ere a Stand 07 2014 Your partner for measuring technolo
4. 1D 84307 Eggenfelden l www acs controlsystem delinfo acs controlsystem de Content 1 2 3 4 10 Brief description Assembly Electrical connection and conenction examples Function description and operation 4 1 Programming software PM TOOL Setting up the device 5 1 Switching on 5 2 Standard parameterisation flat operation level Value assignment for control of the signal input 5 3 Programming interlock RUN Activation Deactivation of the programming interlock or change into extended parameterisation 5 4 Extended parameterisation Superior device functions like e g rescaling of the input signals ENDA OFFA parameterisation of a TARA function TARA zero point slowdown of the input signal ZERO allocation of functions onto the navigation keys adjustment of limit values for optical alarm LI 1 2 safety parameter for locking of the programming CODE input of supporting points for the linearisation of the input signals SPCT Reset to default values Reset of the parameter onto delivery condition Alarms Switching points Functional principle of the optical switching points Technical data Safety advice Error elimination ACS CONTROL SYSTEM GmbH Lauterbachstr 57 1D 84307 Eggenfelden l www acs controlsystem delinfo acs controlsystem de ana a kh A OONN oe ODN NON OO 11 13 14 1 Brief description The panel instrument DAL 101 is a 4 digit device for direct voltage and direct voltage signals via shunt a
5. de 4 Function description and operation Operation The operation is divided into two different levels Menu Level Here it is possible to navigate between the individual menu items Parameterization level The parameters stored in the menu item can be parameterized here Functions that can be adjusted or changed are always indicated with a flashing of the display Adjustments made at the parameterization level should be always confirmed by pressing the P key to save them However the display automatically saves all adjustments and then switches to operation mode if no further keys are pressed within 10 seconds C a Change to parameterization level with the relevant parameters Menu level For navigation at the menu level To confirm the changes made at the parameterization level Parameterization level To change the value or setting Example Parameterization level 4 1 Programming via configuration software PM TOOL MUSB4 You receive the software on CD incl an USB cable with a device adapter The connection is done via a 4 pole micromatch connector plug on the back and the PC is connected via an USB connector plug System requirements PC with USB interface Software Windows XP Windows Vista With this tool the device configuration can be created skipped and safed on the PC Via the easy to handle program surface the parameter can be changed whereat the
6. KA fill level water level pressure temperature flow visualization signal converter sensoric m L IL z J f d Pe de sn p m1 Fam Im T A Ir Fl Yf Cl f lla IQ VJ Pa L II Cul V VU AL DIVIICIDI Vic 7 SLIT it j J III f DL J E a A y Las I OUt V Vi N w i de Lf a i 4 w7 l PRP IC A LA U I LS IEEWV d Technical features e red display of 1999 9999 digits optional green orange or blue display e minimal installation depth 25 mm without plug in terminal e adjustment via factory default or directly on the sensor signal e min max memory e 10 adjustable supporting points e display flashing at threshold exceedance undershooting e tara function e programming interlock via access code e protection class IP65 at the front e plug in terminal e pc based configuration software PM TOOL with CD and USB adapter for devices without keypad for a simple adjustment of standard devices Lf 7 a J ACS CONTROL SYST gt m ale 14 rn Fae A De Knowl VAr nsartnar far mnanSc r nrs Farhbhrnalar ang s kar Your partner Tor measuring recni 10log y di id autor Order code power supply 0 230V AC 2 24V DC galvanic seperated 6 4 20 mA 2 wire current loop display function input 3 Shunt 60 150 mV function output O display 230V AC 24 V DC version O standard configuration S standard protection IP65 DAL 101 Gib ACS CONTROL SYSTEM GmbH Lauterbachstr 57
7. aching the threshold On I i i ia 3 A Va a G i Off Display Hysterisis N Alarms optical setpoint display An activated setpoint can be optically indicated by flashing of the 7 segment display Functional principle of the alarms Deactivated display value Threshold limit value for switch over Width of the window between the thresholds Limit value exceedance limit value undercut 12 ACS CONTROL SYSTEM GmbH Lauterbachstr 57 1D 84307 Eggenfelden l www acs controlsystem delinfo acs controlsystem de 8 Technical data omeno dnain emina Display min 5 max 80 mV 0 60 mV 12 KQO 0 5 of measuring range min 10 max 180 mV 0 150 mV 30 KQ 0 5 of measuring range Accuracy Resolution approx 18 bit at 1s measuring time Power pack 230 VAC 10 max 3 VA 24 VDC 10 max 1 VA Data life 2 100 years at 25 C ACS CONTROL SYSTEM GmbH Lauterbachstr 571D 84307 Eggenfelden www acs controlsystem delinfo acs controlsystem de 1 WW Ambient conditions Working temperature 0 C 60 C Storing temperature 20 C 80 C Weathering resistance relative humidity 0 80 on years average without dew EMV EN 61326 CE sign Conformity to directive 2004 108 EG Safety standard According to low voltage directive 2006 95 EG EN 61010 EN 60664 1 1 4 ACS CONTROL SYSTEM GmbH Lauterbachstr 57 1D 84307 Eggenfelden Iwww acs controlsystem delinfo acs controlsystem de 9 Safety advices Plea
8. esis function exists that reacts according to the functional principle operating current quiescent current Function if display falls below exceeds limit value FU 2 Default HI9H S CELH To indicate if the value falls below the lower limit value LOUU can be selected LOW lower limit value and if it goes above the upper limit value HIGH can be selected HIGH upper limit value LOW corresponds to the quiescent current principle and HIGH to the operating current principle 1 ACS CONTROL SYSTEM GmbH Lauterbachstr 57 1D 84307 Eggenfelden I www acs controlsystem delinfo acs controlsystem de Menu level Parameterization level Setting the code CODE Default 1234 qp e g 8 yee With this setting it is possible to select an individual code works setting 7 2 3 4 for locking the keyboard To lock release the key proceed according to menu item RUN Supporting points number of additional supporting points SPCT Default 0 ga gee In addition to the start and end value 8 extra supporting points can be defined to linearise non linear sensor values Only the activated setpoint parameters are displayed 2 g 2 g P Under this parameter the supporting points are defined on a value basis At the sensor calibration one wi
9. gy and automation
10. ines in the vicinity Connect the screening on one side on a Suitable potential equaliser normally signal ground e The device is not suitable for installation in areas where there is a risk of explosion e Any electrical connection deviating from the connection diagram can endanger human life and or can destroy the equipment e The terminal area of the devices is part of the service Here electrostatic discharge needs to be avoided Attention High voltages can cause dangerous body currents Galvanic isolated potentials within one complex need to be placed on a appropriate point normally earth or machines ground So a lower disturbance sensibility against impacted energy can be reached and dangerous potentials that can occur on long lines or due to faulty wiring can be avoided ACS CONTROL SYSTEM GmbH Lauterbachstr 571D 84307 Eggenfelden Iwww acs controlsystem delinfo acs controlsystem de 15 10 Error elimination 1 The unit permanently indicates e The input has a very high measurement check overflow the measuring circuit e With a selected input with a low voltage signal it is only connected on one side or the input is open e Not all of the activated setpoints are parameterised Check if the relevant parameters are adjusted correctly The unit permanently shows e The input has a very low measurement check underflow the measuring circuit e With a selected input with a low voltage signal it
11. ll be asked at the end like at final value offset too if a calibration shall be triggered Analogue values for supporting points INPI INP8 m 71 nN P g P el Pr Supporting points are always preset according to the selected input signal mV Here the desired analog values can be freely adjusted in ascending order 6 Reset to default values To return the unit to a defined basic state a reset can be carried out to the default values The following procedure should be used e Switch off the power supply e Press button P e Switch on voltage supply and press P button until is shown in the display With reset the default values of the program table are loaded and used for subsequent operation This puts the unit back to the state in which it was supplied Caution All application related data are lost ACS CONTROL SYSTEM GmbH Lauterbachstr 571D 84307 Eggenfelden I www acs controlsystem delinfo acs controlsystem de 1 1 7 Alarms and switching points Functional principle of the switching points Setpoint Limit value exceedance HIGH The setpoint S1 S2 is off below Threshold the threshold and on on reaching On a ee we te E A eS the threshold i t 0 5 Vv A 5 3 Sy ive Off Display Hysterisis Limit value undercut LOW Setpoint The setpoint S1 S2 is on below the threshold and switched off on Threshold ses TE re
12. mode of operation and the possible selection options can be preset via the program CAUTION During parameterisation with connected measuring signal make sure that the measuring signal has no mass supply to the programming plug The programming adapter is galvanic not isolated and directly connected with the PC Via polarity of the input signal a current can discharge via the adapter and destroy the device as well as other connected components 6 ACS CONTROL SYSTEM GmbH Lauterbachstr 57 1D 84307 Eggenfelden Iwww acs controlsystem delinfo acs controlsystem de 5 Setting up the device 5 1 Switching on Once the installation is complete you can start the device by applying the current loop Check beforehand once again that all the electrical connections are correct Starting sequence For 1 second during the switching on process the segment test 8 8 8 8 8 is displayed followed by an indication of the software type and after that also for 1 second the software version After the start up sequence the device switches to operation display mode 5 2 Standard parameterization To be able to parameterize the display press the P key in operating mode for 1 second The display then changes to the menu level with the first menu item TYPE Menu level Parameterization level Selection of the input signal TYPE Default SENS A 5 A A yy U ISO yy y P
13. nd a visual limit value monitoringvia the display The configuration happens via three front keys or via the optional PC software PM TOOL An integra ted programming interlock prevents unrequested changes of the parameter and can be unlocked again via an individual code The electrical connection happens on the rearside via plug interminals Selectable functions like e g the recall of the min max value a zeropoint slowdown a direct change of the limit value in opera ting mode an dadditional measuring supporting points for linearisation complete the modern device concept 2 Assembly Please read the Safety instructions on page 13 before installation and keep this user manual for future reference Gap for physical unit 1 After removing the fixing elements insert the device 2 Check the seal to make sure it fits securely 9 Click the fixing elements back into place and tighten the clamping screws by hand Then use a screwdriver to tighten them another half a turn CAUTION The torque should not exceed 0 1 Nm ACS CONTROL SYSTEM GmbH Lauterbachstr 57 1D 84307 Eggenfelden Iwww acs controlsystem delinfo acs controlsystem de 3 Electrical connection Type DAL 101x300S Type DAL 101x300S supply 230 VAC supply 24 VDC 230 VAC lt 3 VA 0 60 mV 0 60 mV 24 VDC lt 1 VA 0 150 mV 0 150 mV ACS CONTROL SYSTEM GmbH Lauterbachstr 57 1D 84307 Eggenfelden Iwww acs controlsystem delinfo acs controlsystem
14. nlock the keyboard FAIL appears if the input is wrong 5 4 Extended parameterization By pressing the A amp V keys during standard parameterization for one second the display switches to the extended parameterization mode Operation is the same as in standard parameterization Menu level Parameterization level Rescaling the measuring input values ENDA ry ci g Al aGglghgte Rescale the input value of e g 50 mV works setting without applying a measuring signal with this function If sensor calibration has been selected these parameters are not available Rescaling the measuring input values OFFA S aGglghgse Rescale the input value of e g 0 5 mV works setting without applying a measuring signal with this function If sensor calibration has been selected these parameters are not available 8 ACS CONTROL SYSTEM GmbH Lauterbachstr 57 1D 84307 Eggenfelden Iwww acs controlsystem delinfo acs controlsystem de Menu level Parameterization level Setting the tare offset value TARA Default 0 eigener The given value is added to the linerarized value In this way the characteristic line can be shifted by the selected amount Zero point slowdown ZERO Default 0 m lA 03e With zero point slowdown a value range around zero can be preselected at which
15. se read the following safety advice and the assembly chapter 2 before installation and keep it for future reference Proper use The DAL 101 device is designed for the evaluation and display of sensor signals Danger Careless use or improper operation can result in personal injury and or damage to the equipment Control of the device The panel meters are checked before dispatch and sent out in perfect condition Should there be any visible damage we recommend close examination of the packaging Please inform the supplier immediately of any damage Installation The DAL 101 device must be installed by a suitably qualified specialist e g with a qualification in industrial electronics Notes on installation e There must be no magnetic or electric fields in the vicinity of the device e g due to transformers mobile phones or electrostatic discharge e The fuse rating of the supply voltage should not exceed a value of 6A N B fuse e Do not install inductive consumers relays solenoid valves etc near the device and suppress any interference with the aid of RC spark extinguishing combinations or free wheeling diodes e Keep input output and supply lines separate from each other and do not lay them parallel with each other Position go and return lines next to one another Where possible use twisted pair So the best measuring results can be received e Screen off and twist sensor lines Do not lay current carrying l
16. t 0 7 Ann A iv U fy fy Heo ry P The decimal point on the display can be moved with A V and confirmed with P The display then switches back to the menu level again ACS CONTROL SYSTEM GmbH Lauterbachstr 571D 84307 Eggenfelden www acs controlsystem delinfo acs controlsystem de 7 Menu level Parameterization level Setting the display time SEC Default 01 0 mi n AG men EG The display time is set with A Y The display moves up in increments of 0 1 up to 1 second and in increments of 1 0 to 10 0 seconds Confirm the selection by pressing the P button The display then switches back to the menu level again 5 3 Programming interlock RUN Activation deactivation of the programming lock and completion of the standard parameterization RUN Default ULOC nm A nr Al LUL fy Cm Choose between the deactivated key lock ULOC works setting and the activated key lock LOC with the navigation keys A V Make the selection with P After this the display confirms the settings with and automatically switches to operating mode If LOC was selected the keyboard is locked To get back into the menu level press P for 3 seconds in operating mode Now enter the CODE works setting 72 3 4 that appears using the A Y keys plus P to u
17. the display shows zero If for example a 10 is set the display would show a zero in the range from 10 to 10 and continue below it with 11 and above it with 11 Min max value inquiry assignment of key functions TAST Default NO N a x a 5 M Li M Md IIL M Here you can enter for the operating mode either a min max value inquiry or a threshold value correction on the arrow keys If the min max memory is activated with EHER the measured min max values will be saved during operation and can be called up via the arrow keys A V The values are lost if the device is restarted If the threshold value correction Li is selected the limit values can be changed during operation without hindering the operating procedure With TARA the display is tared to zero and is saved permanently as offset The device confirms the correct taring by showing 8000 in the display If NG is parameterized the navigation keys V A have no function in operating mode T L Flashing of display FLAS Default NO AL E Here flashing of the display can be added as an extra alarm function either to the first limit value select Li 7 the second limit value select LI 2 or to both limit values select LI 12 With NO works setting no flashing is assigned at all

Download Pdf Manuals

image

Related Search

Related Contents

Motobineuse - Mr.Jardinage  Randothèque Mode d`emploi Consultation des données sur le site  super kappa (11/2005) - Certificazione Energetica  hochbeet Xl  Mellerware Fan 35950 User's Manual  取扱説明書  Lindy VGA/HD  レイアウト 3  SERVICE MANUAL FOR MODEL 902 AUTOMATIC ANALYZER  Drive Medical Design Plumbing Product 11138-1 User's Manual  