Home
USER GUIDE OCTAN REMOTE
Contents
1. INCLUSION ON BEHALF OF THE GATEWAY Push 3 times quickly on the button The LED blinks in blue Place the device you want to add in Learning Mode within 10 seconds To do so please refer to your device s user guide The LED blinks in green to confirm the inclusion EXCLUSION ON BEHALF OF THE GATEWAY Push 3 times quickly on the button The LED blinks in blue Place the device you want to remove in Learning Mode within 10 seconds To do so please refer to your device s user guide The LED blinks in green to confirm the exclusion ASSOCIATION GROUPS Once set up through the gateway association groups allow direct communication between the remote control and the Z Wave devices you want to control without involving the gateway in the communication The Octan Remote has 7 associations groups Group GroupeName Oooo t Mifele i O 5 Button4 Mono Controlled nodes 6 Button18 amp 3 Duo Controlled nodes Group 1 Lifeline Maximum number of devices in the group 1 This group is dedicated for the home automation gateway Group 2 3 4 5 Maximum number of devices in the group 8 Devices associated in these groups are controlled by the corresponding button according to MONO Profile in the exact same way as Standalone Mode Group 6 7 Maximum number of devices in the group 8 Devices associated in these groups are controlled by the corresponding buttons according to DUO Prof
2. network Push 3 times quickly on the button The LED blinks in blue Place the device you want to disassociate in Learning Mode within 10 seconds To do so please refer to your device s user guide The LED blinks in green to confirm the disassociation INCLUSION Inclusion allows adding a device into the remote control s Z Wave network without associating it with any buttons of the remote control The remote control will then not be able to control your added device Push 3 times quickly on the button The LED blinks in blue Place the device you want to add in Learning Mode within 10 seconds To do so please refer to your device s user guide The LED blinks in green to confirm the inclusion EXCLUSION Exclusion allows removing your device from the remote control s Z Wave network Push 3 times quickly on the button The LED blinks in blue Place the device you want to remove in Learning Mode within 10 seconds To do so please refer to your device s user guide The LED blinks in green to confirm the exclusion GATEWAY MODE When the Octan remote is in Gateway Mode it only communicates with the home automation gateway in order to launch scenes when the buttons are pressed However if your home automation gateway does not support scenes features it is still possible to create direct association between the remote control and the compatible devices you want to c
3. all existing association between the remote control and devices will be lost and would need to be set up again using your home automation gateway interface The existing network of the gateway will be lost as well The procedure is as following Place your home automation gateway into Learning Mode To do so please refer to your gateway s user guide Simultaneously push on and F during sec The LED glows in pink to confirm the selection Push on within 10 seconds The LED blinks in pink to confirm your choice The LED blinks in green to confirm the procedure REMOVE THE REMOTE CONTROL FROM THE NETWORK In order to remove the remote control from the gateway s Z Wave network Place your gateway into Exclusion Mode To do so please refer to your gateway s user guide Simultaneously push on and F during sec The LED glows in pink to confirm the selection Push on within 10 seconds The LED blinks in pink to confirm your choice The LED blinks in green to confirm the procedure Expert Note It s possible to send just a single NIF by following this procedure Simultaneously push on and during 1sec The LED glows in pink to confirm the selection Push on within 10 seconds The LED blinks in pink to confirm your choice GATEWAY MODE FEATURES LART Make sure your gateway supports all the features of the Octan remote compatible gateway are listed on www nodon fr en
4. 1 EN 62479 2011 9 EN 60950 1 2006 A11 2009 A1 2010 EN 300220 1 V2 4 1 amp EN 300220 2 V2 4 1 LOGOTYPE This product is compliant with all relevant European standards When sorting your waste please observe the disposal regulations in force Please place your waste in the facilities provided for that purpose and with all due respect for the environment This product must be used indoor only z nt This product is compatible with Z Wave and Z Wave Plus protocol CONTACT NodOn by ID RF ID RF SAS 121 rue des H tres 45590 St CYR EN VAL FRANCE AFTER SALES www nodon fr section support contact dnodon fr For user guides in other languages please visit www nodon fr notices
5. dim down your associated device light roller shutter etc until you release the button ON amp OFF ON amp OFF Up amp Down Up amp Down Up amp Down Up amp Down ON amp OFF ON amp OFF DUO PROFILE This profile allows controlling your associated device s with two mutual buttons e A short press on or depending on your combination choice during association process will activate ON your associated device s e A short press on or depending on your combination choice during association process will deactivate OFF your associated device s If your associated device s has dimming features light dimmer roller shutter etc e A long press on or depending on your combination choice during association process will dim up your associated device light roller shutter etc until you release the button e A long press on or depending on your combination choice during association process will dim down your associated device light roller shutter etc until you release the button ON ON Up Up Down Down OFF OFF AM It s not possible to cumulate a MONO and DUO profile on the same button Repeat the association process as many times as you want to associate a new device DESASSOCIATION The disassociation deletes any association relationship between the device and the remote control s buttons linked to it However your device will remain in your remote control s Z Wave
6. procedure only when the Primary Controller i e the gateway is missing or defective Reset the remote control does not mean that it has been removed from the Primary Controller memory Remove the remote controller through the Primary Controller before performing a factory reset STANDALONE MODE By default the Octan remote is in Standalone Mode It means it can control compatible Z Wave devices without involving the gateway The Octan remote acts as the Primary Controller of the network While the remote control is in Standalone Mode you can Control one or several devices up to 8 with only 1 button MONO Profile Control one or several devices up to 8 with 2 buttons DUO Profile AM You must not unplug a Z Wave device definitely without removing it from the remote control s Z Wave network first See the Exclusion part below This can have a serious impact on the battery lifetime ASSOCIATION Careful Before associating a not recently bought device please perform an EXCLUSION first Please refer to the Exclusion section below Association is performed in 3 steps Push 3 times quickly on the button to activate the Association Mode The LED glows in blue Choose which button will control your device within 10 seconds e A short press on one of the buttons of the remote control O or will activate the MONO Profile The pressed button will then control your d
7. USER GUIDE OCTAN Remote with wall support Reference CRC 3 1 0x Power supply CR2032 battery Radio frequency 868MHz Range up to 80 meters outdoor Range up to 40 meters indoor Operational temperature 10 C 50 C IP20 Radio protocol Z Wave Plus 500 series Dimensions 80 mm L x 80 mm U x 17 5 mm h Weight 68 g with wall plate Warranty 2 years The NodOn Octan remote can be added and operated in any Z Wave network with other Z Wave certified devices from other manufacturers and or other applications All non battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network It has 2 distinctive working modes 1 STANDALONE MODE The Octan remote can control Z Wave compatible devices directly such as the NodOn Smart Plug or a light dimmer whoever is the manufacturer Note No home automation gateway is involved and necessary in this mode 2 GATEWAY MODE The Octan remote is in Gateway Mode as soon as it is added in a Z Wave network managed by a home automation gateway The remote control becomes then the gateway s assistant capable to launch up to 16 different scenes through it SCENE Profile or directly associated to your Z Wave compatible devices MONO or DUO Profile WALL SUPPORT A magnetic wall support is included with your Octan Remote This support can be screwed screws not included or fixed by adhesive bonding
8. evice e A long press on the button will activate the DUO Profile combined with the button The ON and OFF buttons will then control your device e A long press on the button will activate the DUO profile combined with the button The f ON and OFF buttons will then control your device The LED blinks in blue to confirm your choice Place the device you want to associate in Learning Mode within 10 seconds To do so please refer to your device s user guide The LED of the remote control blinks green to confirm the association process eo In case of a too long association process or others problems during the process the LED will blink red Timeout Please restart the procedure Once the association is validated your remote control is able to control your device Different actions are possible MONO PROFILE This profile allows controlling your associated device s using just a single button of the Octan remote A short press on O or depending on your choice during association process will activate ON your associated device s a second short press will deactivate OFF your associated device s If your device has dimming features light dimmer roller shutter etc e A long press on the O or depending on your choice during association process will dim up your associated device light roller shutter etc until you release the button e A second long press on the same button will
9. ile in the exact same way as Standalone Mode CONFIGURATION PARAMETERS Buttons profile MONO DUO SCENE in Gateway Mode are set up through several configuration parameters BUTTONS 1 amp 3 PROFILE Default Value Size C a a 1 byte To set up the profile of buttons 1 amp 3 Value Description SCENE DUO BUTTONS 2 amp 4 PROFILE Parameter Number Default Value Sze o O 2 Ooo o 1 byte To set up the profile of buttons 2 amp 4 Value Description SCENE DUO SCENE TYPE Default Value Size ee E Poe 1 byte To choose the way of sending Scene to the gateway We strongly advise you to use CENTRAL SCENE which is more user friendly However some home automation gateways don t support CENTRAL SCENE yet then you can still use the previous standard SCENE ACTIVATION The user interface of your gateway will then allow you to set up scenes BUTTON 1 CONFIGURATION Parameter Number Default Value i ee Se 1 byte To set up the how button 1 behaves when set in MONO Profile Value 2 BUTTON 2 CONFIGURATION DefaultValue Size Pp Mhyte O Value 2 BUTTON 3 CONFIGURATION DefaultValue Size_ a 0 1 byte To set up the how button 3 behaves when set in MONO Profile Parameter Number Parameter Number Value Description 2 BUTTON 4 CONFIGURATION Parameter Number DefaultValue Size 7 PT d O To set up the how button 4 behaves when se
10. included The remote control embeds a small magnet allowing fixing it on its wall support or on any metallic surface fridge door heater etc BATTERY REPLACEMENT The Octan remote operates using a CR2032 coin cell battery included To replace the battery slide slowly the battery cover located on the backside of the remote Before the first use take care of removing the battery protector after opening the battery cover AM In order to save as much as possible the battery life time avoid too long learning process and place the remote control as close as possible to the device you want to associate OCTAN REMOTE INTERFACE The remote control has 4 buttons and one LED located at the center of the product BATTERY LEVEL In order to know the battery level a simultaneous short press on and must be performed The LED will display the battery level according to below table Battery level Under 50 Between 50 and 20 Red Below 20 A FACTORY RESET A factory reset will completely delete the memory of the remote control and restore all the parameters to default value A simultaneous long press 1sec on and will perform this factory reset The LED will blink red and green to validate the reset AAM In Standalone Mode make sure to remove all the devices added or associated in the remote control s network before performing a factory reset In Gateway Mode use the factory reset
11. ontrol through configuration parameters and association groups Nonetheless if supported it is strongly advised to use scenes in order to enjoy the best experience and increase the battery lifetime In order to put your remote control into Gateway Mode you just have to add the remote control into the gateway s Z Wave network Procedure as following Place your home automation gateway into Inclusion Mode To do so please refer to your gateway s user guide Simultaneously push on and F during sec The LED glows in pink to confirm the selection Push on within 10 seconds The LED blinks in pink to confirm your choice The LED blinks in green to confirm the procedure LAMEN If your remote control controlled before some devices in Standalone Mode these devices will remain orphans Make sure you remove or reset all devices previously added or associated into the remote control s network before placing the remote control in Gateway Mode If your home automation gateway supports the Controller shift feature you can recover the existing remote controls network while it is in Standalone Mode when you pass into Gateway Mode Your home automation gateway will be added into the remote controller s network and set as the main controller All the information related to the added devices will be automatically copied to the home automation gateway during this process However
12. t in MONO Profile Value Description po ControtGroup 5 _ O pt AS WitchON O When the selected profile is SCENE default value the remote control communicates only with the home automation gateway The user interface of your gateway will then allow you to set up scenes based on which and which way you press the different buttons To do so please refer to your gateway s user guide The different actions that can be handled by the remote control are e Simple press on O or e Double press on O or Long press on O or e Button released on O or Which makes a total of 16 different actions It is strongly advised to use this profile if supported by your gateway However if your home automation gateway does not support these features you can still use association groups and set up your buttons as e MONO Profile to control the corresponding group or activate the Z Wave All Switch ON or All Switch OFF features e DUO Profile to control the corresponding groups LED MANAGEMENT Parameter Number_ DefaultValue Size po o d O How to set up LED behaviour Description No LED Flash Blue after button press Blinking to confirm command Both options above 1 amp 2 COMMAND CLASS The Octan remote supports the following Command Class Controlled only not supported Controlled AND supported DECLARATION OF CONFORMITY EN 301489 1 V1 9 2 amp EN301489 3 V1 4
Download Pdf Manuals
Related Search
Related Contents
manuel d`utilisation de la série 50 309844C - PrecisionFlo LT, Standard, Spanish AC CURRENT OSCILLOSCOPE PROBE E N G L I S H User Manual MSI MS-6380 Motherboard O2 Nokia 5250, Prepaid Pack Black Caractérisations des déchets organiques et évaluation du potentiel User Guide Guide de l`éleveur pour l`identification des porcins User`s Manual HAL BRP Copyright © All rights reserved.