Home
Operating instructions
Contents
1. 61000 6 1 10 EN 61000 6 2 11 10 60 C lt 80 non condensing vertical splash proof and drip proof 50 x 276 x 148 mm 50 x 301 x 148 mm about 1 500 g about 1 600 g CKB 100 9650 50 Headend Controller Headend control unit with 8A power supply HCB x00 Part N 965x 0x 10 Programming 10 1 Main program BLANKOM ENTER Y foe A Selection modules Address selection CG Type article number see operating instructions of the module gt Change module NIT distribute display distribute static NIT an key Temperature display temperature an J gt OF key Voltage display voltage an gt gt key Current display current an Configuration gt Q gt Language gt Time gt System restart key display selection german english display selection hours minutes display selection starting time Contrast display selection gt gt Version display version gt Reset System restart gt IP number 10 2 Adjustments Manuel adjustment Adjustment of the addresses at the Bus Extender BEB x00 and at the modules Activation of the dat
2. A yes 9 A typical yes yes lt 14 5 V ll acc DIN VDE 0860 4 IP 20 according DIN VDE 0871 curve B 5 10 55 C 48 V DC 36 72 V DC 2 4 A max 125 W fold back at 110 143 16 8 20 V 8 A 10 43 C 6 A 55 C 1500 V DC input output EN 55022 CIS PR22 Class B 6 EN 61000 4 2 3 4 6 8 7 ENV 50204 8 our 48 V DC 36 72 V DC Plug with screw termina tion with polarity protec tion Fuse Polarity reversal protection Power consumption Voltage stability AC Output DC voltage Rippled noise ratio Output current Current limit Short circuit protection Overvoltage protection Protection class Noise emission Immunity Temperature range Environmental conditions Relative humidity Mounting method Mounting location Physical information Dimensions I x w x h without 19 adapter with 19 adapter Weight HCB 200 300 9653 02 HCB 300 9653 01 Delivery contents 1 x Power cord or connector 1 x Screw driver 2 x Wrenches 4 x Terminal resistance 75 Q 2 x Multipole sockets Software options SNMP activation to reset device 2 minutes without voltage gt 6 A only use bus cable 8 A T 6 3 A 250 V H 5x20 internal yes max 110 W 1500 V input output 12V 66 dB 0 25 8 A yes yes hicc up mode yes gt 14 5 V IP 20 EN 55011 9 EN 55022 CIS PR22 Class B 6 EN 50083 2 2 EN
3. BLANKOM Professional Headend Solutions Operating instructions Headend Controller Headend control unit with 8A power supply Contents 1 Safety and operating instructions 00 0 ec eeee eee eeeeeeeeceeeeeeeeeeeaaeeeeeeeeeeteeeeneas 2 2 DEVICE VATA S eosi ra rE Aae A AERE Ti AETR 2 3 Generalerna e ia E Ea a aaa iaa 2 Ac FROME MIQW oiiro annia aE Ea EE S EEA Aan pR 3 5 FUNCHONAl COSCKIPUOM sccccsissisnisoninnriiiinni innia 3 6 Head end bus Structure 5 s c5 ea iieeete accede A helen el See apace eee 3 6 1 Minimum configuration without Bus Extender c ccceeeeeeeeeeeeeeeees 3 6 2 Standard configuration with Bus Extender cceceeeeeeeeeeeeeeneeeees 4 7 Head end DUS SVUCIUTO cisciecececstvesedestidicccdestent acedeneiticeeeeiwe E 4 8 Redundant y CIRCUIT s enrian aA AE RNEER NEERA 4 9 Alarm fUnCUON ccccceivescccetevvencecceteevsnneseentveandcenwevvenne cease vnnneewenvvvndeeeeevvanndeedeviys 5 TOs TECMMICAN daanin kaea a sha deacon cts taiecenssh A ladesotiveadactecbeats 5 11 Programming senecionis Einni En nE ENEE Meccan acca 6 101 Maim PROQHAIM sierran EAEE EE E A 6 10 2 ACjUStIMOMMS cesccccccteterecncesceeee et iecdeneynteneldnviindeneste is neddistiveaeiabberienaceenetes 6 10 3 Subroutine Change configuration 0 cccceceeeeteeeeeeeeeeeeeeettaeeneneees 7 10 4 Adjusting of the IP NUMDE 0 0 0 cee eect ceeee eects eeeeeeeeeeaeeeeeeeeeetaaeeeeneees 7 TAs IBIBO Gia Y eonenn nar ani E ava EAE
4. E EERE TE EEE 8 12 Document MSto sasini E n anea AEAEE 9 HCB x00 2 gt Part N 965x 0x HCB x00 Headend Controller Part N 965x 0x Headend control unit with 8A power supply 1 Safety and operating instructions 8 4 When assembling starting up and adjusting the modules it is necessary to consider the system specific references in the manual instruction The modules may only be installed and started up by authorized technical personnel When assembling the modules into the receiving points the adherence of the EMC regulations is to be secured The assembly and wiring have to be done without voltage All active modules may only be operated with the Headend Controller HCB x00 or Bus Extender BEB x00 The main voltage and the operating voltage of the modules working by DC have to be in complience to the operating parameters described in the technical data With all work the defaults of the DIN EN 50083 have to be considered Especially the safetyrelevant execution of the DIN EN 60728 11 1 is necessary gt gt gt hee 2 Device variants HCB 200 9652 01 Headend control unit with 8A power supply 100 240 V input HCB 300 9653 01 Headend control unit with 8A power supply 48 V input HCB 300 9653 02 Headend control unit with 8A power supply 48 V input 3 General The Headend Controller HCB x00 is a module of the head end system B LINE which can also be used in the head end system C LINE C LINE Th
5. EN 61000 4 8 Electromagnetic compatibility EMC Part 4 8 Testing and measurement techniques Power frequency magnetic field immunity test IEC 77A 694 FDIS 2009 German version FprEN 61000 4 8 2009 8 ENV 50204 Radiated electromagnetic field from digital radio telephones Immunity test 1996 02 15 HCB x00 Headend Controller Part N 965x 0x Headend control unit with 8A power supply 9 EN 55011 Industrial scientific and medical equipment Radio frequency disturbance characteristics Limits and me thods of measurement IEC CISPR 11 1997 modificated A1 1999 A2 2002 German Version EN 55011 1998 A1 1999 A2 2002 10 EN 61000 6 1 Electromagnetic compatibility EMC Part 6 1 Generic standards Immunity for residential commer cial and light industrial environments IEC 61000 6 1 2005 German version EN 61000 6 1 2007 11 EN 61000 6 2 Electromagnetic compatibility EMC Part 6 2 Generic standards Immunity for industrial environ ments IEC 61000 6 2 2005 German version EN 61000 6 2 2005 12 Document history Version Date Modification Author 1 00 15 04 2009 basic document HauBer Rudolph 1 01 30 07 2009 revision HauBer 1 02 15 12 2009 revision program flow HauBer 1 03 11 01 2010 insert of HCB 300 9653 01 HauBer 1 04 19 01 2011 insert of HCB 300 9653 02 HauBer 1 05 22 06 2015 new company HauBer Options available upon request Subjects to changes due to t
6. a input at the Headend Controller HCB x00 by pressing the ENTER key Display adjustment of the parameter of the HCB x00 ora selected module as in chapter 11 1 Activation of the programming modus of each module by selecting the line BEB x00 and the module position 01 15 at the Headend Controller HCB x00 the yellow LED at the module will be lit up til the beginning of the parameter adjustment Adjustment of the parameter at the selected module accor ding to the individual product description After the programming the data will be transmitted automa tically to the modules the yellow LED on the HCB x00 will be lit up during the data transfer process The green LED shows the operating status ENTER Going back Going forward only available for HCB 200 Adjustment with the PC laptop An online connection after IP standard and an ethernet connection at the PC laptop is necessary for the remote programming Adjustment of the line position addresses at the Bus Exten der BEB x00 as well as at the modules At the HCB x00 IP address input e g 192 168 001 001 For direct connection between a PC and HCB x00 use a crossed patch cable RJ 45 For connection over a deviation use an uncrossed patch cable HTML browser start up and IP address as target address input If connected correctly the HTML control surface at the PC will open up and a blue LED LINK at the HCB x00 will be lit up All adju
7. ad end bus structure 6 1 Minimum configuration without Bus Extender HCB x00 Module ADDR 00 Module ADDR 01 E i Module ADDR 15 HCB x00 Headend Contoller The number of the possible module connections 00 15 toa BEB x00 depends on the total power consumption of this line HCB x00 Headend Controller Part N 965x 0x Headend control unit with 8A power supply 6 2 Standard configuration with Bus Extender HCB x00 Headend Controller HCB x00 m Module Module ADDR 01 ADDR 01 ADDR 15 ADDR 15 Module signal processing unit BEB x00 ADDR 15 Module ADDR 01 ADDR 15 The number of the possible module connections 01 15 toa BEB x00 depends on the total power consumption of this line 7 Redundancy circuit Power supply redundancy HCB x00 ADDR 01 Module ADDR 15 redundancy supply broken ADDR 01 Module ADDR 15 BEB x00 ADDR 15 Module ADDR 01 ADDR 15 Description of the power supply redundancy With the redundant operation of a system the control unit HCB x00 will automatically take over the function of the power supply if the Bus Extender BEB x00 is failing HCB x00 Part N 965x 0x 8 Alarm function Headend Controller Headend control unit with 8A power supply To activate the alarm function is additional hardware 9651 01 or 9651 02 necessary The device is endorsed by an additional alarm function and current limitations voltage drops and communi
8. cation disturbaces The contact 13 in the communication and supply bus is switched 5V to 0 V in case of alarm The alarm modules are available in 1 RU and in panel form It is possible to insert the modules in any order into bus system The si gnal is fed to a SUB D 9 connector via relais in case of alarm All the contacts are galvanically isolated It is possible to trigger several kinds of alarm 9 Technical data Manual operation Input Display Remote control Network connection LAN WAN Input connection Address extent Without Bus Extender With Bus Extender Power supply HCB 200 Mains voltage Voltage frequency Mains connector Internal device fuse Power consumption Output DC voltage Rippled noise ratio Current drain Current limit Short circuit protection Overvoltage protection Protective system Protection class Radio noise suppression Temperature range Power supply HCB 300 9653 01 Input voltage Input current at 48 V Power consumption Overcurrent protection Overvoltage protection Max current drain Voltage stability Radio noise suppression Power supply HCB 300 9653 02 Input voltage Input connection 3 operating keys reset key LCD lit 19 x 28 mm Ethernet 10 Base T RJ 45 16 modules 240 modules 15 x 16 100 240 V 10 5 47 Hz 63 Hz built in connector EN 60320 1 C8 IEC 320 C8 3 G5x20 T4A IEC 127 2 V max 110 W 12V 66 dB max 8
9. e B LINE system is conceived as a complete system for middle sized distribution networks the C LINE C LINE for smaller distribution networks All active modules are programmed via the central Headend Controller The individual modules will be addressed by the address switch at the Bus Extender line BEB x00 and at the respective module position The status of the modules will be displayed by colored LEDs Red ERROR Control bus error Green READY Operating status Yellow DATA Data traffic at the internal control bus RJ 45 socket Yellow DATA Data traffic LAN WAN Blue LINK Connection HCB x00 Headend Controller Part N 965x 0x Headend control unit with 8A power supply 4 Front view HCB 200 M 7 HCB 300 Display HEADEND CONTROLLER E a HEADEND CONTROLLER POWER SUPPLY POWER SUPPLY Type HCB 200 Part No 9652 01 Control keys Type HCB 300 Part No 9653 02 INPUT VOLTAGE AC 100 240 V EEEESS INPUT VOLTAGE DC 36 72 V INPUT FREQUENCY 50 60 Hz Reset key INPUT POWER max 110 W INPUT POWER max 110 W ALARM SOURCE yes ALARM SOURCE yes ADDRESSING SPACE max 240 UNITS OUTPUT DC 12V max 8A OUTPUT DC 12V max 8A Operating voltage control bus X1 X2 LED ERROR red ERROR LED READY gre
10. echnical progress BLANKOM systems GmbH Hermann Petersilge StraBe 1 07422 Bad Blankenburg Germany Phone 49 0 3 67 41 60 0 Fax 49 0 3 67 41 60 100 C Declaration of Conformity Manufacturer BLANKOM systems GmbH Hermann Petersilge Stra e 1 07422 Bad Blankenburg Germany Product Name Headend Controller Type Name HCB 200 HCB 300 Type N 9652 01 9653 01 9653 02 BLANKOM systems GmbH confirms that the mentioned products meet the guideline s of the Council for the approximation of legislation of the member states Electromagnetic compatibility 2004 108 EC The following standards are met DIN EN 50083 2 2007 04 EN 50083 2 2006 06 Low voltage guideline 2006 95 EC The following standards are met DIN EN 60950 1 2006 04 EN 60950 1 2006 1 1 Information technology equipment Safety Restriction of hazardous substances 2011 65 EC The following standards are met DIN EN 50581 2013 02 EN 50581 2012 Bad Blankenburg Germany 2015 06 22 Wolfgang Schl ter Managing Director
11. en LED DATA yellow h LAN WAN ee Taran LED DATA yellow ee LAr Bee LED LINK blue e en Power supply 5 Functional description The Headend Controller HCB x00 is the central control module of the head end or the individual switch cabinet It consists the data interfaces to a PC LAN WAN and to the Bus Extender BEB x00 The head end internal data bus has to be connected as seen in chapter 6 to 8 and the alarm function is descriped in chapter 9 Both bus connections X1 and X2 can be used for that The data inter face to a PC LAN WAN is implemented as a IP Ethernet interface RJ 45 Programming can be done but also directly at the control unit see programming By pressing the reset key the HCB x00 reboots and all data of the head end are read out again The internal power unit supplies the control unit and in case of a Bus Extender BEB x00 error it will switch automatically to the respective line The Headend Controller HCB 200 and HCB 300 9653 02 have an integrated current display but the HCB 300 9653 01 hasn t this function It is recommended to use an individual control unit for every circuit switch cabinet The IP address of each control unit can be edited and adapted to the respective LAN Additional information Redundancy circuit Headend Controller chapter 8 Structure minimum configuration chapter 6 Option SNMP and DHCP 6 He
12. stments of the modules are specified at the control surface Adjustment of removal of write protection Removal of write protection by input of 0000 password and 0000 user Default IP Address 192 168 2 80 HCB x00 Headend Controller Part N 965x 0x Headend control unit with 8A power supply 10 3 Subroutine Change configuration Address selection direct input or selection All characters all characters numbers amp capital letters only gt Back 10 4 Adjusting of the IP number Adjusting facilities of IP numbers XX OF ZZ see next figure xx OF ZZ see next figure xx OF ZZ see next figure XX OF ZZ see next figure XX OF ZZ see next figure xx OF ZZ see next figure VEA EMA IP number Software option 9650 50 HCB x00 Headend Controller Part N 965x 0x Headend control unit with 8A power supply Subroutine Change IP number change 11 Bibliography 1 EN 60728 11 Cable networks for television signals sound signals and interactive services Part 11 Safety IEC 60728 11 2005 German version EN 60728 11 2005 2 EN 50083 2 Cabled distribution systems for television and sound signals Electromagnetic compatibility for equipment EN 50083 2 2001 3 EN 60320 1 Appliance couplers for household and similar general p
13. urposes Part 1 General requirements IEC 60320 1 2001 A1 2007 German version EN 60320 1 2001 A1 2007 4 DIN VDE 0860 Audio video and similar electronic apparatus Safety requirements IEC 60065 2001 modified A1 2005 modified German version EN 60065 2002 A1 2006 Cor 2007 A11 2008 5 DIN VDE 0871 Radio noise suppression of high frequency units Determination of limits for industrial scientific and me dical equipment identical with CISPR 23 1987 6 EN 55022 Information technology equipment Radio disturbance characteristics Limits and methods of measurement IEC CISPR 22 2005 modified A1 2005 German version EN 55022 2006 A1 2007 7 EN 61000 4 2 Electromagnetic compatibility EMC Testing and measurement techniques Electrostatic discharge immunity test 2009 05 31 EN 61000 4 3 Electromagnetic compatibility EMC Part 4 3 Testing and measurement techniques Radiated radio frequency electromagnetic field immunity test IEC 61000 4 3 2006 A1 2007 German version EN 61000 4 3 2006 A1 2008 EN 61000 4 4 Electromagnetic compatibility EMC Part 4 4 Testing and measurement techniques Electrical fast transient burst immunity test IEC 61000 4 4 2004 German version EN 61000 4 4 2004 EN 61000 4 6 Electromagnetic compatibility EMC Part 4 6 Testing and measurement techniques Immunity to con ducted disturbances induced by radio frequency fields IEC 61000 4 6 2003 A1 2004 A2 2006
Download Pdf Manuals
Related Search
Related Contents
SP-1200-72 - One World Touch Fireplace Manual Manual cHiMenea Motores De Inducción C.A. En potencias Integrales Marshall Amplification 1987X-PW User's Manual Bedienungsanleitung Halo RL560SN6827 Instructions / Assembly MB3 Owners Manual - Optima Heating & Air Conditioning Kobo Touch eReader USER GUIDE こちら Copyright © All rights reserved.