1. BLANKOM Professional Headend Solutions Operating instructions Power supply module 9 amps HELIOS P1 2 Part N 5150 10 ae Selig Sispuals HELIOS P1 Power supply module 9 amps Contents 1 Safety and operating instructions Device variants General Device view 4 1 Front view 4 2 Rear view Functional description Meaning of status LED s Technical data Bibliography Document history HELIOS P1 Part N 5150 10 Power supply module 9 amps 1 Safety and operating instructions gt PRPBRBPRP BP RBRPPRP O When assembling starting up and adjusting the modules it is necessary to consider the system specific references in the manual instruction The modules may only be installed and started up by authorized technical personnel When assembling the modules into the receiving points the adherence of the EMC regulations is to be secured The assembly and wiring have to be done without voltage All active modules may only be operated with the power supply HELIOS or HELIOS P1 The main voltage and the operating voltage of the modules working by DC have to be in complience to the operating parameters described in the technical data With all work the defaults of the DIN EN 50083 have to be considered Especially the safety relevant execution of the DIN EN 60728 11 1 is necessary The HELIOS P1 module comes under protection classification It is absolutely necessary therefore to ins
2. Donor open Germany a Oo 5 Functional description The HELIOS P1 module is the power supply of the processing units modules The total power consumption of all connected mo dules may not exceed the current limit of the HELIOS P1 The unit has an over voltage protection shutdown Increases the output voltage to 14 V by a malfunction of the power supply eg interruption of the controlled system then an independent monitoring circuit is activated and turns off the power Erasing this state is only possible by separating the power supply from the mains After a required latency of around 1 2 minutes the control circuit is reset and power supply can be connected to the mains If the malfunc tion is still not resolved then the described process is repeated again The HELIOS P1 is insensitive to load side external voltages because power and energy are limited by a suppressor diode The start up takes place under all load conditions and a capacitive loads up to 12 000 uF across the overall temperature range The unit has an inrush current which is engaged actively and is limitting consumtion to 50 A during hot and cold start and power interruptions 6 Meaning of status LED s POWER Unit is ready off Unit is off operating voltage not applied OVERLOAD Overload on the output for example to many consumers off Load is within limits HELIOS P1 Part N 5150 10 7 Technical data Electrical ch
3. aracteristics Main voltage Mains frequency Mains connector Power consumption Output voltage Ripple noise ratio Current drain Current limit Short circuit protection Overvoltage protection Internal fuse Protection class Protection standard Radio noise suppression 8 Bibliography 1 EN 60728 11 Cable networks for television signals sound signals and interactive services Part 11 Safety Power supply module 9 amps 100 240 V 10 5 47 63 Hz built in connector according DIN EN 60320 1 IEC 60320 C14 3 max 127 W 12V 66 dB max 9A yes 10 A typical yes yes lt 14 5 VY G5 x 20 T4A IEC 127 2 V according DIN EN 61140 VDE 0140 1 4 IP 20 according DIN VDE 0871 curve B 5 IEC 60728 11 2005 German version EN 60728 11 2005 Environmental conditions Temperature range Relative humidity Mounting method Mounting location Miscellaneous Dimensions I x w x h Weight Delivery contents 10 55 C lt 80 not condensing vertical splash proof and drip proof 46 x 262 x 167 mm ca 1 200 g 1x power cord 1x DIN rail clip 1x mounting accessories 2x dummy connector 1x ground mount kit To reset device interrupt the mains voltage 2 minutes 2 EN 50083 2 Cabled distribution systems for television and sound signals Electromagnetic compatibility for equipment EN 50083 2 2001 3 EN 60320 1 Appliance couplers for household and similar gen
4. eral purposes Part 1 General requirements IEC 60320 1 2001 A1 2007 German version EN 60320 1 2001 A1 2007 Corrigendum to DIN EN 60320 1 VDE 0625 1 2008 05 4 DIN EN 61140 VDE 0140 1 Protection against electric shock Common aspects for installation and equipment IEC 61140 2001 A1 2004 modified German version EN 61140 2002 A1 2006 5 DIN VDE 0871 Radio noise suppression of high frequency units Determination of limits for industrial scientific and medical equipment identical with CISPR 23 1987 9 Document History Version Date Modification 1 00 06 06 2012 basic document Options available upon request Subjects to changes due to technical progress BLANKOM Antennentechnik GmbH Hermann Petersilge StraBe 1 07422 Bad Blankenburg Germany Phone 49 0 3 67 41 60 0 Fax 49 0 3 67 41 60 100 C Declaration of Conformity The Manufacturer BLANKOM Antennentechnik GmbH Hermann Petersilge Str 1 07422 Bad Blankenburg Germany herewith declares the conformity of the product Product name Power supply module 9 amps Type HELIOS P1 Product number 5150 01 according to the following regulations EN 50083 2 EN 60728 11 as far as relevant and additional device specific regulations enclosed above which this product is subjected to Date 06 06 2012 Signature S en Piero Kirchner Managing Director
5. ert the mains plug into a fused socket The ventilation slots of the modules are to be kept absolutely free When rail mounting the DIN rail clip is mounted with 2x countersunk screws M4 enclosed in the accessory tray The enc losed housing feet is mounted to the corresponding mark on the rear panel see 4 2 At the rear there is a connection option for an additional ground wire For installation of the protective conductor 1x lens M4 K serrated lock washer and lock washer enclosed in the accessory tray should be used WEEE Reg Nr DE 50389067 2 Device variants HELIOS P1 5150 10 Power supply 9 amps 100 240 V input 3 General The Smart Business Line SBL is a modern head end system that is distinguished by its modular and compact design A user friend ly operating concept facilitates setup configuration and maintenance of the system The HELIOS P1 is a power supply 9 amps of the SBL The status of the module will be displayed by LED s HELIOS P1 Part N 5150 10 Power supply module 9 amps 4 Device view 4 1 Front view 4 2 Rear view O BLANKOM HELIOS P1 Device label 5150 102 ce o gatea ai Attachment points for DIN rail clip Operating voltage L LED OVERLOAD red LED POWER green Connection for additional protective earth Mark for housing feet for DIN rail mounting Power supply connection 7 O A Caumon