Home

User Guide for Web Electrical Socket V 3.2.9(.x)

image

Contents

1. active during single switching 1 USER GUIDE 11 Example Socket 3 daily switching Choose below the point Time switch gt Socket 3 gt Daily The following page will appear White Socket 3 Heizung Daily switching active Astro time action 7 DO v 00 switch off 7 41 y 00 switch off Ea Ea 2h gt after gt sunrise Ir 14 y 05 switch off 14 y 05 7 switch off 14 y 05 switch off y 14 y 05 switch off y 14 7 05 switch off 14 y 05 switch off X 14 y 05 switch off back Save Figure 9 The setting of daily switching actions First of all you click on the checkbox below the point active in the line in which you want to change settings Then choose the time or select Astro to switch the sockets depending on the sunrise or sunset Determined the type of switching You have the possibilities to determine ten points in time at which the socket shall be switched daily Confirm your entry with Save The data that were entered by you will be arranged chronologically When you want to delete a switching action remove the checkmark at the beginning of the respective line and click Save The settings for particular weekdays take place in the same way as the settings for daily switching All settings will be implemented parallel If a socket shall be turned on and off at the same time then the switching off process has priority 1 USER GUIDE 12 Via Time switch
2. gt Display error_log you can display which onetime switching actions for example because of a blackout could not be conducted This data can be deleted by the button delete error_log 16 06 2011 18 04 Profile Ersatz On 16 06 2011 at 18 02 socket 3 was not switch on 22 06 2011 08 18 Profile Ersatz On 22 06 2011 at 08 16 socket 1 was not switch on 30 06 2011 02 59 Profile Ersatz On 22 06 2011 at 16 16 socket 1 was not switch off 10 07 2011 02 59 Profile Ersatz On 03 07 2011 at 06 16 socket 1 was not switch on back delete error_log Figure 10 Display error_log 1 USER GUIDE 13 1 3 3 Temperature Switching Temperature switching provides you the possibility to switch a socket depending on the ambient temperature Select on the homepage Switching gt Temperature switching The following page will appear Current temperature 24 C Configure Temperature switching Temperature values Socket 1 Socket 2 Socket 3 Temperature value 1 34 C gt 37 ec 24 C Temperature value 2 20 C 22 C 26 C Switch the socket depending on the upper and lower temperature Socket 1 Socket 2 Socket 3 Lampe Pumpe Heizung Figure 11 Temperature dependent switching The current temperature will be shown You also have the possibility here to enter two temperature threshold for a switching action of the socket Further down you can select how the particular socket sh
3. Below the menu item Settings gt Network you configure the socket board individ ually for your network By clicking on the box before LAN or WLAN you chose how your electrical socket shall connect with the network Both ways can operate parallel Confirm your settings always with Apply 1 USER GUIDE 19 LAN Configuration Please decide first of all whether you want to use the con nection via DHCP or a LAN adapter with a fixed IP address If your router is set on DHCP the IP address can be assigned automatically By entering the hostname into your browser you connect with your Electrical Socket tested with FritzBox The other way to connect is by using the IP address the router has allocated to the LAN adapter If your DHCP has not been set or you want to have a fixed IP address for the LAN adapter fill out the box IP Address Netmask Gateway and DNS In the box Gateway enter your routers IP address in the box Netmask enter the netmask sub netmask In the box IP address please enter the IP address that the LAN adapter of your Electrical Socket shall get If your netmask is called 255 255 255 0 the first three fields of the IP address need to correspond with those from your gateway The last field is decided by the individual address Please make sure that no other device that is connected to this network is being used In field DNS you generally enter the IP address of your router but you can also enter an alternative DNS
4. for any material and personal damage that is the result of inappropriate operating or disregarding the safety information For security and authorization reason it is not allowed to convert or change the device arbitrarily Please consider the security information and instructional devices for the con nected devices Please consider the security information of the individual chapters of this man ual instructions Do not let the packing materials laying around carelessly they could become a dangerous toy for your children The electrical installations and equipment s in industrial facilities must be observed by the security regulations and insurance institutions If you are not aware of a correct connections or may there be any question that have not been answered in the user guide please contact us Return of old devices If the control of a socket board with temperature monitoring becomes worn out please bring your worn out device to the community recycling center e g recycling depot The worn out device needs to be disposed separately from your household rubbish According to the electric and electronic device law the owner of an old device is lawfully upheld to dispose old electric and electronic devices separately from the household rubbish Please assist and contribute your share to environmental protection by not disposing your old devices in the household trash 5 DOC DECLARATION OF CONFORMITY
5. profile 1 OFF 2 OFF 3 ON gt Manual switching gt Temperature curve Configure Time switch download area Current switching status max temperature 24 C temperature in C min temperature 22 C 26 N Y w 8 3 ES 10 00 11 00 Figure 4 Home Page of the Electrical Socket When you put the web electrical socket into service for the first time please choose the menu item Settings and configure the web electrical socket For the actual switching procedures and temperature monitoring you find the menu items left in the navigation box or respectively as a navigation point on the front page By clicking on this menu item Home you return to this page at any time 1 USER GUIDE 7 1 3 Switching 1 3 1 Manual Switching Select the menu item Switching gt Manual Switching on the homepage The fol lowing page will appear W hlke Switching Socket 1 on of Lampe Socket 2 On off Pumpe Socket 3 On off Heizung Figure 5 Manual switching The current state of the socket is shown in the socket picture Using the button which is located below the socket picture the individual sockets can be turned on or off 1 USER GUIDE 8 1 3 2 Time Switch The function of a time switch enables you to determine the times at which your socket turns on or off For every individual socket a single daily or weekly point in time can be defined at which it shall turn on or off These settings wi
6. the form xx xx xx xx in the address bar of your browser This will take you to the home page of the electrical socket 1 2 2 Deactivate DHCP in the router In order to create a connection with the socket you need to change the settings on your computer according to the following information e IP address 192 168 101 x gt x any except 6 e IP subnet mask 255 255 255 0 e Gateway 192 168 101 254 ATTENTION Vote on your computer the previous settings before you change them as they are important for your internet access After the commissioning of the socket board you need to recover these settings Type the IP address 192 168 101 6 into your web browser You are now at the front page of the homepage For control purposes the electrical outlet number 2 will turn on for a short moment until it will switch back to the set position 1 USER GUIDE 6 1 2 3 Home Page of the Electrical Socket On the front page you receive all the important information such as the current temperature chosen profile the latest switching status of the socket as well as the temperature profile of the last 24 hours With every restart the temperature profile will start from the beginning again During operation the homepage is updated every 10 seconds W hlke Home Websteckdose Current temperature 22 C Current profile Sommer gt Configure temperature monitoring Configure temperature switch Configure profile Current
7. 27 60 Update URL http www woehlke dyndns de update php token dca1 3de5531 f422d56a00d4174e62ac2 4 back to host selection Figure 27 Overview of the host details Here you can see the current ip address which you can change if required Depending on the router DDNS must be enabled Enter your user name and pass word of the DDNS service as well the Host name IP address and the update URL The following diagram shows this configuration with the Fritz box 7390 FRITZ Box 7390 Angemeldet w FRITZ Box FRITZINAS MyFRITZ 0 bersicht Internet Online Monitor Zugangsdaten Filter Freigaben Freigaben Portfreigaben FRITZ Box Dienste Dynamic DNS Uber Dynamic DNS k nnen Anwendungen und Dienste fiir die in der FRITZIBox Firewall Portfreigaben eingerichtet wurden unter einem festen Domainnamen aus dem Internet erreicht werden obwohl sich die ffentliche IP Adresse der FRITZ Box mit jeder Interneteinwahl ndert MyFRITZ DSL Informationen Telefonie Heimnetz WLAN DECT System Y Dynamic DNS benutzen Geben Sie die Anmeldedaten f r Ihren Dynamic DNS Anbieter an Dynamic DNS Anbieter Benutzerdefiniert al Neuen Domainnamen anmelden Update URL http www woehlke dyndns de up Domainname Steckdose woehlke dyndns de Benutzername Mustermann 8 Kennwort bernehmen Abbrechen Hilfe Ansicht Standard Inhalt Handbuch Tipps amp Tricks N
8. 40 5 DOC Declaration of Conformity The company W hlke EDV Beratung GmbH Gr tzmacher Str 4 D 28844 Weyhe Tel 49 421 802791 0 Fax 49 421 802791 18 info woehlke edv de www woehlke edv de declares hereby that the product Web Electrical Socket agrees with the clauses of the following EU guidelines 2004 108 EG Electromagnetic compatibility 2006 95 EG low voltage directive 1999 5 EG telecommunication directive and the following norms were applied EN 55022 2010 AC 2011 Establishment of information technology Radio interference properties limiting values measurement method EN 55024 2010 Establishment of information technology Interference immunity properties limiting values testing procedure EN 61000 3 2 2006 Electromagnetic compatibility Part 3 2 Limiting values for harmonic currents EN 60950 2006 Security of facilities of the information technology EN 300328 V 1 7 1 Radio spectrum Matters in the 2 4 GHz ISM band Weyhe April 23 2013 Prof Dr Eng W W hlke Business Executive
9. User Guide for Web Electrical Socket V 3 2 9 x Please note Sure to read before handling March 6 2015 W hlke EDV Beratung GmbH Gr tzmacher Str 4 28844 Weyhe Contents 1 User Guide 4 deli o A A A 4 T2 A OMA TIVIS SOMITE a Die Date Be ESE de do Se se 5 1 2 1 Activate DHCP in the router 5 1 2 2 Deactivate DHCP in the router 6 4 06 24 44 ela es 5 1 2 3 Home Page of the Electrical Socket 6 o a A A 7 1 3 1 Manual Switching a8 eo a opos Sue ea ee T de Lime A ae a DE Oe tbe aat 8 1 3 3 Temperature Switching ooa a 13 TA Monitoringa eoe oe it A aia le Eee 15 1 4 1 Temperature Monitoring ca 22 5 2 22 2a a ad 15 1 4 2 Temperature curve aoaaa rs at 16 Tor t oetUneS lee sa a a di e 17 1 5 Ys eto Time AAA le tasek ad Er a Sed 18 1 5 2 Network Settings de a Soups ic da tGoe s 18 1 5 3 Hostname and Webserver o 20 1 5 4 Password Protection 2 32 ld Ban a ee 21 1 5 5 On position and Labeling 21 1 5 6 Switching states at missing temperature sensor 22 1 5 7 Further Settings A A a Ar ae st aunt A 22 1 0 Download a cot A A AA A te eke ee e 24 17 Updates acei bo a ESE e ee OD aed hw a BGS 25 1 8 Information NA ISA td A ee a de 26 1 9 Network settings and Password resetting 27 1 10 Create a Domain via woehlke dyndns de 28 LAI Technical Datat zes psp rar Oe eo ae ER e 32 1 12 System Re
10. all switch If you want the socket to turn on below the temperature threshold and to turn off above the temperature threshold you should select choice number two If you want the socket to turn on above the temperature threshold and to turn off below the temperature threshold choose option number three If the socket shall not switch depending on the ambient temperature select option number one deactivate In order to apply the settings confirm with Apply 1 USER GUIDE 14 An example A profile is created and you have set socket no 1 and no 2 in a way that they turn on at 8 00 and turn off at 22 00 every day Now you decide that a temperature sensor should be connected to socket no 3 and that this socket should always turn on above 30 C and turn off below 20 C Time switch for no 3 is inactive So switch off all switching times for the third socket Now click on the menu item Temperature switching and enter temperature value 1 20 C and temperature value 2 30 C Fi nally you activate option number three for socket no 3 and then confirm your entry with Apply Socket no 1 and no 2 continue to turn on at 8 00 and turn off at 22 00 but socket no 3 only turns on if the ambient temperature of 30 C exceeds and turns off if the ambient temperature comes below 20 C Combination of time switch and temperature switching is also possible when a pro file is selected for the timer The switching state has priority which is set under Settin
11. ar W hlke Socket 2 Pumpe One time switching active Astro date time action 2 19 March 1 2013 10 oo gt switch on 2 29 gt June 2013 gt 3h after I sunrise swtchon gt 7 10 August 2013 11 05 switch off 16 May 2013 13 59 gt switch off 16 May 2013 13 s9 switch off 16 May 2013 13 59 T7 switch off 16 gt May 2013 13 59 gt switch off a m ie may 2013 13 59 T switch off gt O O 16 may 2013 gt 13 59 gt switch off Ir 16 May 2013 13 59 switch off Ir back Save Figure 8 Setting of onetime switching actions First of all you select the checkbox below the point active in the line in which you want to change settings Choose a date time and switching action in this line or select Astro to switch the sockets depending on the sunrise or sunset You have the possibility to determine ten onetime moments at which the socket shall be switched Confirm your entry with Save The data that were entered by you will be arranged chronologically When you want to delete a switching action remove the checkmark at the beginning of the respective line and click Save Attention In case of a blackout or any other incident that prevents the Electrical Socket from switching there will be an entry error_ log data This function is only
12. ard 802 11b g n WEP WPA WPA2 encoding e Length 482 mm e Width 74 mm e Height 45 mm 1 12 System Requirements The homepage was tested on the browsers Internet Explorer 7 0 8 0 and Firefox 3 6 16 For the display of the homepage Java Script needs to be activated in your browser 1 USER GUIDE 33 1 13 Smartphone App 1 13 1 System requirements The requirement for the installation and operation of the remote control with the help of the smartphone is a successful installation of the Web Electrical Socket in your home network It is also important that the Web Electrical Socket must have a selected domain which is generated by a dyndns service to get access over the internet for example http Steckdose 2013 dyndns org 65000 If these conditions are met the Web Electrical Socket can be remotely controlled with a smartphone app There is a version for the Apple iPhone with OS operat ing system version 6 1 as well as for smartphones with Android operating system version 2 3 3 and higher 1 13 2 Initial Installation Search the App Store Apple for WebSockManager or the Google Play Store Android for WebSock Manager and install the app on your smartphone The app is free Now start the app you will see the setup screen Settings Menu Auto Refresh El Time 0 CU IE Profiles Click short on a profile for option Figure 30 Setup Screen The slider for the auto update on off sets if the disp
13. ate of the display 1 USER GUIDE 36 1 13 4 Other Settings 1 Tap on the Status screen on the area menu gt Change profile on the following screen you can select another profile Refresh Quick Connect Switching Settings About Temperature 18 Socket 1 On Misc Switch off switched on manually Socket 2 On Misc Switch off switched on manually Socket 3 On PC Switch off Figure 33 Status screen Switching Tap on the selected profile and the status screen of the selected profile appears By tapping on the area Add Profile you return to the new profile form and can create another profile lt Status Quick Con websocket1 192 168 2 27 websocket2 192 168 2 87 Add Profile Figure 34 Change profile 1 USER GUIDE 37 2 On the status screen by tapping on the area Menu gt Setting you return to the setup Screen Settings Menu Auto Refresh E Time 10 C D Profiles Click short on a profile for option websocket1 192 168 2 27 192 168 2 87 Figure 35 Settings screen 3 On the status screen by tapping on the area Menu gt About will take you to the page of the manufacturer s contact details 4 On the setting screen by tapping on the area Menu gt Add Profile will take you back to the entry form for creating a further profile 5 On the setting screen by tapping on the area M
14. computer click the link download with the right mouse button Choose from the following selection to the point Save file as Give a destination and confirm with Save The saved files are text files that can be edited with a simple text editor Also you find a link to download the usermanual 1 USER GUIDE 25 1 7 Update The Electrical Socket is equipped with an automatic update function which makes it possible if required to search for updates of the software automatically W hlke Info Softwareupdate can take about four minutes Advice Restart the Web Electrical Socket before update Important Please don t switch off the Web Electrical Socket during the software update otherwise the software could be damaged Figure 23 Update function When you click on the button Run update updates will be downloaded and installed automatically Upon successful update a status message appears just as if your software is up to date 1 USER GUIDE 26 1 8 Information W hlk EDV e Software 3 2 5 2 www woehlke websteckdose de Hardware 3 1 0 W hlke EDV Beratung GmbH Gr tzmacher Str 4 LAN MAC 00 05 14 01 5c 1c 28844 Weyhe WLAN MAC 7c dd 90 1e b5 47 Germany Phon 49 421 80 27 91 43 LAN IP 192 168 101 9 Fax 49 421 80 27 91 18 WLAN IP 192 168 2 63 state online E Mail info woehlke websteckdose de Last time update 16 07 28 05 2014 Figure 24 Information On the informati
15. conds all individual settings in time switching temperature monitoring and temperature switching will be deleted and set back to factory settings A reset differs from a reboot to the effect that resetting as described restores it to the factory settings and a reboot only restarts the system 1 USER GUIDE 28 1 10 Create a Domain via woehlke dyndns de In order to connect to the socket via the internet the socket needs to be connected to an online router In addition the IP address of the router needs to be known and the IP address can be assigned automatically and has to be fixed If a fixed IP address is not assigned to the router by the internet provider the IP address of the router will be changed every 24 hours The service provided by W hlke EDV Beratung can assign a quasi steadily IP ad dress to the router Thereby it is made possible to connect to the web electrical socket via a domain Moreover the IP address of the web electrical socket cannot be obtained automatically but has to be assigned consistently In order to obtain a domain proceed as follows Enter in your browser the address www woehlke dyndns de and select on the home page the menu item new account start new account login my account contact amp Create new account first name last name e mail adress desired username amp password 7 repeat password desired hostname select
16. domain woehlke dyndns de v send oder started w account login imprint hike dyndns de Figure 25 Form Create Account 1 USER GUIDE 29 Fill out the displayed form Confirm your entry with send The email address that you have entered can only be used once If there is a problem during the account creation and you try to create an account again you have to use an alternative email address Afterwards you will receive an email to the email address which you have stated in the form Follow the link in the email and log in with your chosen user name and password on woehlke dyndns Now select one by one the menu items my account gt add new host to open the following window w hlke Add another host to your account new hostname SA Steckdose woehlke dyndns de satenesnane 4 back to host selection start logout imprint www woehlke dyndns de Figure 26 Create a host on woehlke dyndns Enter in new Hostname your individually selected domain name and select a domain ending so that you domains name is for example Steckdose woehlke dyndns de Save your Hostname and Select back to host selection or my account Next click on the created domain name in order to get an overview of the host details 1 USER GUIDE 30 cazas 4 Benutzer TobiasWallasch El overview host details sil hostname Steckdose woehlke dyndns de current IP 0 0 0 0 new IP 91 49 1
17. enu gt Change Profile you can chose an other profile in this screen 6 On the setting screen by tapping on the area Menu gt Status you go back to the status screen and the current information of the Web electrical socket with the se lected profile will be displayed 2 SAFETY INFORMATION 38 2 Safety Information Please consider when putting up connecting and operating the socket the following hints e Put the device on a non slip mat e Lay the connections accident proof e Do not put the device close to sources of heat in direct sun light or close to electrical devices e Protect the device from wetness dust aggressive liquids and steam e Connect only to authorized user e Research has proven that in some cases medical devices can be influenced by wireless signals For that reason please observe the regulations of medical facilities before using the web electrical socket within these facilities e Never open this device by yourself never touch the socket with lacy and metal objects and never carry the device at the connection cord e Never use the device in wet rooms e g bathroom or in explosion prone areas e Do not use the provided temperature sensor in liquids 3 SAFETY STATEMENT 39 3 Safety Statement For any damage or harm that is the result of disregarding this instruction manual the warranty claim expires For consequential damage we do not assume liability 4 We do not assume liability
18. ewsletter avm de Figure 28 DynDNS configuration with the FRITZBOX 7390 1 USER GUIDE 31 Finally a port forwarding in your router is set up FRITZ Box 7390 Angemeldet FRITZ Box FRITZINAS MyFRITZ w bersicht Portfreigabe ca memet Portfreigabe bearbeiten Online Monitor m _ Zugangsdaten Portfreigabe aktiv f r Andere Anwendungen v Filter Bezeichnung HTTP Server eigen Protokoll TCP 1 He von Port 30000 bis Port 30000 DSL Informationen P an Computer Steckdose v Telefonie Hemmnetz an IP Adresse 192 168 263 WLAN an Port 80 DECT System 0K Abbrechen Hilfe Ansicht Standard Inhalt Handbuch Tipps amp Tricks Newsletter avm de Figure 29 Port release with the Fritzbox 7390 Now you can connect the homepage of your socket via the selected domain Example http Steckdose woehlke dyndns de 30000 1 USER GUIDE 32 1 11 Technical Data e Connections x mains current connection 3x load current connections 1 x Ethernet connection RJ45 1x Jack connector for Temperature sensor e Power supply 230 VAC e Power consumption 2 5 W e Switching capacity per Electrical Socket 3600 W the maximum of 3600 W for all three sockets must not be exceeded e Network connection 10 100 Mbps WLAN up to 150 Mbps e Protocols TCP IP e Working temperature 0 C 40 C e Operating Humidity 10 85 non condensing e WLAN transmission stand
19. gs gt More Switching types gt Priority More detailed descriptions of the switching behaviour can be found from page 21 chapter 1 5 7 Other Settings Please note that the temperature dependent switching can be delayed by a few seconds 1 USER GUIDE 15 1 4 Monitoring 1 4 1 Temperature Monitoring Connect the supplied temperature sensor with the front side of the socket Choose on the homepage the menu item Monitoring gt Temperature monitoring The following page will appear W hlke Monitoring Current temperature 24 C Configure Temperature monitoring Temperature values Temperature value 1 12 C Temperature value 2 27 ec Additional Email text Temperatur Email Account Email address n skyline gmx de Username n skyline gmx de Password Mail server mail gmx net e g mail provider org Mailserverport 25 SSL Receiver Email 1 max mustermann gmx net Email 2 abc test com Email 3 Apply Figure 12 Temperature indicator and settings The current temperature will be shown on the socket board at the temperature sensor The temperature range of the sensor lies between 40 C and 100 C On the homepage you have the possibility to enter one or two temperature thresh olds If you do not want to enter any thresholds please select in the appropriate field deactivate In the following fields you can enter information about your email account and
20. lay is updated regularly when the system is in operation The slider for time specifies the time in seconds between updates If Auto Update is disabled the slider can not be activated 1 USER GUIDE 34 The names of already created profiles are also shown on this screen Type the name of an existing profile so you can change it using the form below First you must create a profile On the Setup screen tap on Menu gt New Profile In the following form enter the profile title the device address an username and a password and tap Save lt Back New Profile Profile title Deviceaddress Username Password Figure 31 Form New Profil The profile is created Select this profile and tap on Connect 1 USER GUIDE 35 1 13 3 Status screen Once you have selected a profile the status screen appears Refresh Status Menu Switching Testbed Temperature 18 C Socket 1 On Misc Switch off switched on manually Socket 2 On Misc Switch off switched on manually Socket 3 On PC Switch off switched on manually Figure 32 status screen The first line shows the name of the selected profile The measured temperature is shown such as the switching status ON OFF of the three sockets with their labels By tapping the large areas you can switch the three sockets on or off The caption of the tip surfaces changes accordingly Tapping the Refresh button force an immediate upd
21. ll be saved in your profile and you can create up to four profiles Select the menu item Switching gt Time switch on the homepage It appears on the following page W hlke Switching Create profile name no deakt Info By the replacement of a profile all entries of the previous profile create a profile are deleted Select a profile dealt Selected profile Sommer Apply Figure 6 Choice and creation of a profile 1 USER GUIDE 9 At least one profile needs to be created and afterwards at least one profile needs to be chosen After the profile is chosen and you pressed Apply the following page appears W hlke EDV BERATUNG Switching Create profile name no deakt Info By the replacement of a profile all entries of the previous profile are deleted create a profile Select a profile deat Selected profile Sommer Apply coordinates latitude 53 longitude 8 8 Current Times Sunrise 05 11 Sunset 21 32 es Chose switching moment Socket 1 Lampe One time Edit Socket 2 Pumpe One time 5 Edit Socket 3 Heizung One time Edit Display error_log Figure 7 Selection of a time switch Now you can choose which socket should be turned off 1 USER GUIDE 10 Example Socket 2 Single switching Choose below the point Time switch gt Socket 2 gt One time and click on Edit The following page will appe
22. n individual hostname if you let DHCP automatically assign an IP ad dress The default hostname is websteckdose In this case you can connect with your Electrical Socket by entering the hostname into your browser tested with FritzBox With the item point Webserver you can set alternative HTTP and HTTPS ports By default port 80 for HTTP and port 443 for HTTPS is set If necessary enter an alternate port and confirm your choice with apply In this case enter the alternative port address always with a colon when you want to achieve the electrical socket Examples 192 168 101 6 65000 websteckdose 65000 1 USER GUIDE 21 1 5 4 Password Protection Password protection New username Mustermann New password Repeat new password e Apply Figure 18 Create a password Below the menu item Settings gt Password Protection you have the possibility to protect the access of your homepage with a password Fill in the fields and confirm your entry with Apply 1 5 5 On position and Labeling Below the menu item Settings gt Other you can specify a base state Switching states at power up inscription Socket 1 Son off Pumpe Socket 2 on off Heizung Socket 3 on a off Lampe Apply Figure 19 Set the on position This state will be adopted by the socket after the socket board was connected to the electricity grid or has been turned on or alternatively after a blackout Choose the desired state for every s
23. ocket board You can also enter a label for every single socket board Confirm your entry with Apply 1 USER GUIDE 22 1 5 6 Switching states at missing temperature sensor Below the menu item Settings gt Other you can specify a base state when the temperature sensor fails or is removed Switching states at missing temperature sensor Socket 1 on off Tip Only if temperature switching of the Socket 2 son off respective socket is activated Socket 3 Son off Apply Figure 20 Switching states at missing temperature sensor The sockets go into these defined state when running during the operation and the temperature sensor fails or is removed and the temperature switching is activated for the respective socket regardless of the programmed switching states 1 5 7 Further Settings Below the menu item Settings gt Other you will find further settings Time Switch and Temperature Switching Temperature sensor Priority switch on Type 3m Apply Apply Reboot Service Tip The system of the Web Power Control will be Tip Only for service engineers intended restarted Apply Apply Figure 21 Further Settings Under Temperature Sensor you can chose between three types of sensors There are 3m 10m and 20m 1 USER GUIDE 23 Under the point Reboot you can restart the system which should not be mistaken with Reset chapter 1 11 which sets the settings back to factory settings Under More Switching t
24. on page on the website you can find contact information from the company Wilfried W hlke EDV Beratung GmbH including telephone number fax number email address On that site you can also find the newest software and hardware versions as well as MAC and IP addresses for LAN and WLAN adapters The date of the last time synchronization can also be checked Your see weather the electrical socket in on or offline 1 USER GUIDE 27 1 9 Network settings and Password resetting The socket board is equipped with a reset key In case you forget the IP address of your socket and or your password for the homepage you can reset the socket with the reset key back to factory settings Hereto you have to hold the reset key for at least 3 seconds The reset key is located on the right next to the LAN connector and needs to be pressed by a thin object for example a paper clip After reset the following values are set for the socket e IP address LAN 192 168 101 6 if there is not DHCP e IP address WLAN 192 168 101 7 not active e Net mask 255 255 255 0 e Gateway 192 168 101 254 e DNS 192 168 101 254 e Connection via LAN e DHCP LAN adapter on e Hostname websteckdose e Username non e Password non e Webserver HTTP Port 80 e Webserver HTTPS Port 443 The settings you have created for the time switch temperature monitoring and temperature switching are saved despite the reset If you push the rest button longer than 15 se
25. quirements a aa ei Ka 32 LAS Smartphone App Y ioy PK Sid Ses WBE E e a BE ek o a Gk 33 1 13 1 System requirements Y o td e 33 1 13 2 Initial Installation 2451004400 2 2 ne 33 1 13 3 Sta t s SCrEEI in a e o tete 35 1 13 41 Other Settings rea o od o EO oe E e 36 2 Safety Information 39 3 Safety Statement 4 Return of old devices 5 DOC Declaration of Conformity 40 40 41 1 USER GUIDE 4 1 User Guide 1 1 Overview Figure 1 Multiple Socket Outlet 1 Main on off switch 2 4 Sockets 1 2 3 5 Adapter Power Cable 6 Adapter LAN cable temperature sensor RESET button Figure 2 Head side without connecting cable Figure 3 Head side with connecting cable 1 Adapter temperature sensor 2 Adapter LAN Cable 3 RESET button 1 USER GUIDE 5 1 2 Commissioning Connect the socket board via LAN wire with the router Plug the power plug in the socket Turn on the socket using the green switch on the front side 1 2 1 Activate DHCP in the router Wait 30 second until you start a web browser for example Mozilla Firefox Enter the hostname of your electrical socket The default hostname is named websteckdose By entering http websteckdose you reach the home page of the electrical socket tested with FritzBox If you have no success with this installation login to your router and find out the IP address that was assigned to the LAN adapter of your electrical socket Enter the IP address determined in
26. server WLAN Configuration Up to the field Network name SSID you can precede the same as in the LAN configuration When you have already configured the LAN settings assign a individual IP address for the WLAN adapter Then enter the network name SSID which is set on your router for WLAN Spaces in the network name are not supported so please remove possible spaces from your SSID By clicking on the button Scan network all picked up networks will be shown Choose the right network Preset security options WPA mode and encryption key These settings need to correspond with the router s security settings Your WLAN password can not contain special characters 1 USER GUIDE 20 Network settings check If you have changed the IP address of your computer during the first settings restore the original settings Test your computer by check ing if it can connect with the internet In order to get to the homepage of the socket board enter your selected hostname into your browser tested with FritzBox and DHCP or use the individual IP ad dress of your electrical socket Via this entry every computer that uses the same network can access to the homepage of the socket board If you cannot connect with the Electrical Socket check the settings and start maybe again with the first settings 1 5 3 Hostname and Webserver Hostname Webserver Websteckdose HTTP Port 80 Apply Apply Figure 17 Hostname and Webserver You need a
27. settings below can be made Confirm your entries in the corre sponding sections always by Apply otherwise changes will not be accepted e Date and time e On position of the socket board and labeling e Network connection LAN and or WLAN e Hostname e Password protection for the homepage e Webserver HTTP Port e Priority for simultaneous operation of timer and temperature switching e Reboot the system e Used temperature sensor 1 USER GUIDE 1 5 1 Date and Time Current 16 05 2013 New manual Area Berlin Apply 18 see o Synchronise with the internet Figure 15 Adjust date and time Below the menu item Settings gt Date Time you have the possibility to set date and time You can also state whether you would like to synchronize the data with the internet Online synchronization will always start at 12 00 am In order to adjust date and time please choose the desired values and confirm your entry by Apply 1 5 2 Network Settings LAN configuration EILAN connected Get IP address automatically Using the following IP address IP address 192 Netmask 255 Gateway 192 DNS 192 Apply 168 255 168 168 101 255 101 101 254 102 WLAN configuration WLAN connected Get IP address automatically Using the following IP address Network name SSID DSLEK Security options WEP Key s unn nnos Scan network Figure 16 Network settings
28. three email addresses If the entered threshold is exceeded or deceeded 1 USER GUIDE 16 an email is send to every email address with information about date and time Confirm your entry with Apply Consequently a test email is sent to the entered email addresses If temperature monitoring is active you will get an e mail every time you restart the electrical socket 1 4 2 Temperature curve The function Monitoring gt Temperature curve shows the temperature history of the last 24 hours Optionally you can also view the progress of the last 7 days or 28 days You have also the possibility to download the hourly temperature values in a CSV file up to 365 days W hlke Monitoring Temperature profile of the last 24 hours temperature in C 27 AA gt o_o oo o gt A o o op 14 00 15 00 16 00 17 00 18 00 19 00 20 00 21 00 22 00 23 00 00 00 01 00 02 00 03 00 04 00 05 00 06 00 07 00 08 00 09 00 10 00 11 00 time max temperature 25 C min temperature 23 C 24 hours 7 days 28 days download Temperature logfile Figure 13 Temperature curve over 24 hours 1 USER GUIDE 17 1 5 Settings In order to adjust the individual settings to the socket board choose the menu item Settings on the homepage W hlke Current 16 05 2013 ill New manual Synchronise with the internet Area Berlin Ir Apply Figure 14 Settings of the socket board On this page the
29. ypes you can define the default priority This setting is rele vant when Time Switch while Temperature Switching is used The priority has the following effects Priority switch on Socket switch on when Time Switch or Temperature Switching switch on Socket switch off when Time Switch and Temperature Switching switch off Priority switch off Socket switch off when Time Switch or Temperature Switching switch off Socket switch on when Time Switch and Temperature Switching switch on Default is switch on Select the switch priority and confirm your entry by Apply 1 USER GUIDE 24 1 6 Download The Electrical socket logs all switching operations and e mail dispatches in log files that can be read with this function Ware Download Log file switching events download User manual link to user manual Log file Email dispatch download Figure 22 Download log file To view these files click with the left mouse button on the link download The recent shifts are displayed with time and cause of the circuit manual timer or temperature switching On temperature switching you can also see the current temperature at shifting time The log file for switching operations is limited to 1000 entries and when an overflow occurs the oldest entries are deleted first In the e mail logfile date time and number of the registered e mail address 1 2 or 3 is displayed and the status OK or ERROR To save the files on your