Home
AVTrac 482 User Guide
Contents
1. Architectural Connectivity AVTrac Floor mount Raceway with Modular AAP Connectivity for A V Data and Power Ase o gt Extron Electronics Ee bs N o ov INTERFACING SWITCHING AND CONTROL uri 68 1803 01 Rev B 12 10 Precautions Safety Instructions e English A This symbol is intended to alert the user of important operating and maintenance servicing instructions in the literature provided with the equipment P This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product enclosure that may present a risk of electric shock Caution Read Instructions e Read and understand all safety and operating instructions before using the equipment Retain Instructions The safety instructions should be kept for future reference Follow Warnings Follow all warnings and instructions marked on the equipment or in the user information Avoid Attachments Do not use tools or attachments that are not recommended by the equipment manufacturer because they may be hazardous Consignes de S curit Francais Cesymbolesert avertirl utilisateur que la documentation fournie avec le mat riel contient des instructions importantes concernant l exploitation et la maintenance r paration Ce symbole sert avertir l utilisateur de la pr sence dans le boitier de l appareil de tensions dangereuses non isol es posant des risques d lectrocution Attention Lire
2. O Secure the connectivity box to the track and floor page 12 Step 3 Install AC Power Module if needed O Seat and secure the power module in the connectivity box page 13 O Run the AC conduit and connect to the junction box page 13 Step 4 Install Architectural Adapter Plates AAPs O Install AAPs in the connectivity box cover panel page 14 O Run and connect the cables to the AAPs page 14 Reattach the cover panel page 14 Step 5 Complete Installation O Snap on the cover track page 15 O Cut and glue the carpet to the side and end ramps pages 15 and 16 O Trim the wall base boards and apply the carpet or rubber strip finish to cover the track raceway page 16 Extron USA West Headquarters 800 633 9876 Inside USA Canada Only 1 714 491 1500 1 714 491 1517 FAX Extron USA East 800 633 9876 Inside USA Canada Only 1 919 863 1794 1 919 863 1797 FAX Extron Europe 800 3987 6673 Inside Europe Only 31 33 453 4040 31 33 453 4050 FAX Extron Asia 800 7339 8766 Inside Asia Only 65 6383 4400 65 6383 4664 FAX Extron Japan 81 3 3511 7655 81 3 3511 7656 FAX Extron China 400 883 1568 Inside China Only 86 21 3760 1568 86 21 3760 1566 FAX Extron Middle East 971 4 2991800 971 4 2991880 FAX 2010 Extron Electronics All rights reserved www extron com
3. n no intentar personalmente la reparaci n mantenimiento de este equipo ya que al abrir o extraer las tapas puede quedar expuesto a voltajes peligrosos u otros riesgos Ranuras y aberturas Si el equipo posee ranuras o orificios en su caja alojamiento es para evitar el sobrecalientamiento de componentes internos sensibles Estas aberturas nunca se deben obstruir con otros objetos Bater a de litio e Existe riesgo de explosi n si esta bater a se coloca en la posici n incorrecta Cambiar esta bater a nicamente con el mismo tipo o su equivalente recomendado por el fabricante Desachar las bater as usadas siguiendo las instrucciones del fabricante SE as BIS e VS Ae En Epos AS HD ChE ERE BH AEN EER HRA TR EAC s ds HRA KARR MEER EFE TREE SU T FL PRA HRA BS e KEMER mort KEYP UR RAAB MAVEN AE ABET KEARAH REEL SEPA AE PES A SRE 66 D UR LG AN ACAR IP BER si T HET VAT SUL e FAS ALE EA EEL CIR RIEL UROL PEI UL B AB e NIE MAE BG EI ES iE HIS AGERE BELARUS lH US Bruto 12 BR AE P DROE Bernat wE Lh EG HARI RSH FS ARE NEEL RI ARV FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2
4. O Db i l I T 7 l E 2 92 7 42 SIDE VIEW END VIEW Product weight Parts in package 1 of 3 14 9 lbs 6 7 kg Parts in package 2 of 3 8 9 Ibs 4 0 kg Parts in package 3 of 3 8 9 lbs 4 0 kg Shipping weight Parts in package 1 of 3 20 Ibs 10 kg Parts in package 2 of 3 11 Ibs 5 kg Parts in package 3 of 3 11 Ibs 5 kg Aere e cares Svid Erde Sod ISTA 1A in carton International Safe Transit Association Regulatory compliance Safety M C UL UL Accessibility Title Ill Regulation 28 CFR Part 36 ADA Standards for Accessible Design Section 4 8 Ramps VE ne RTT 3 years parts and labor NOTES All nominal levels are at 10 Specifications are subject to change without notice AVTrac Specifications 19 Reference Information Optional Accessories AVTrac Accessories Part Number AVTrac 4 feet Track Extension Kit 70 645 04 Connectivity Box AAP Enclosure 70 801 02 AC Power Modules US Prewired Conduit 70 799 08 AC Power Modules Four US Outlets Prewired Conduit 70 799 09 AC Power Modules Central Europe Isolated Cable 70 799 03 AC Power Modules France Isolated Cable 70 799 04 AC Power Modules Australia Conduit only 70 799 05 AC Power Modules Universal Outlet Isolated Cable 70 799 06
5. les instructions Prendre connaissance de toutes les consignes de s curit et d exploitation avant d utiliser le mat riel Conserver les instructions Ranger les consignes de s curit afin de pouvoir les consulter l avenir Respecter les avertissements e Observer tous les avertissements et consignes marqu s sur le mat riel ou pr sent s dans la documentation utilisateur Eviter les pi ces de fixation Ne pas utiliser de pi ces de fixation ni d outils non recommand s par le fabricant du mat riel car cela risquerait de poser certains dangers Sicherheitsanleitungen Deutsch Dieses Symbol soll dem Benutzer in der im Lieferumfang enthaltenen Dokumentation besonders wichtige Hinweise zur Bedienung und Wartung Instandhaltung geben Dieses Symbol soll den Benutzer darauf aufmerksam machen da im Inneren des Geh uses dieses Produktes gef hrliche Spannungen die nicht isoliert sind und die einen elektrischen Schock verursachen k nnen herrschen Achtung Lesen der Anleitungen Bevor Sie das Ger t zum ersten Mal verwenden sollten Sie alle Sicherheits und Bedienungsanleitungen genau durchlesen und verstehen Aufbewahren der Anleitungen Die Hinweise zur elektrischen Sicherheit des Produktes sollten Sie aufbewahren damit Sie im Bedarfsfall darauf zur ckgreifen k nnen Befolgen der Warnhinweise Befolgen Sie alle Warnhinweise und Anleitungen auf dem Ger t oder in der Benutzerdokumentation Keine Zusatzger te e Ver
6. une batterie du meme type ou d un ype equivalent recommande par le constructeur Mettre au reut les batteries usagees conformement aux instructions du fabricant Vorsicht Stromquellen e Dieses Ger t sollte nur ber die auf dem Produkt angegebene Stromquelle betrieben werden Dieses Ger t wurde f r eine Verwendung mit einer Hauptstromleitung mit einem geerdeten neutralen Leiter konzipiert Der dritte Kontakt ist f r einen Erdanschluf und stellt eine Sicherheitsfunktion dar Diese sollte nicht umgangen oder au er Betrieb gesetzt werden Stromunterbrechung Um das Ger t auf sichere Weise vom Netz zu trennen sollten Sie alle Netzkabel aus der R ckseite des Ger tes aus der externen Stomversorgung falls dies m glich ist oder aus der Wandsteckdose ziehen Schutz des Netzkabels e Netzkabel sollten stets so verlegt werden dafs sie nicht im Weg liegen und niemand darauf treten kann oder Objekte darauf oder unmittelbar dagegengestellt werden k nnen Wartung e Alle Wartungsmafsnahmen sollten nur von qualifiziertem Servicepersonal durchgef hrt werden Die internen Komponenten des Ger tes sind wartungsfrei Zur Vermeidung eines elektrischen Schocks versuchen Sie in keinem Fall dieses Ger t selbst ffnen da beim Entfernen der Abdeckungen die Gefahr eines elektrischen Schlags und oder andere Gefahren bestehen Schlitze und ffnungen e Wenn das Ger t Schlitze oder Locher im Geh use aufweist dienen diese zur Vermeidung einer berhitzun
7. 1 Low profile Raceway System 1 AAP Compatible Connectivity Box 1 Multiple Accessories n nnnnnennennnnnennnnennne 1 ADA Complant 1 Choice of Einisbes 1 ECKE 2 BOK Toran 2 Checklist for contents of box 1 2 BOX65 2 and i3 EE 3 Checklist for contents of box 2 3 Checklist for contents of box 3 3 Before Getting Started 4 Wett Le SEU T 4 Floor Considerations 4 In Wall Cable Routing Considerations 4 Room Considerations 5 ADA Compliance ssooannneneneennnneonneneeeenne 5 Tools and Equipment Required Before SEAR GG OM BEE 6 JD UE d e ssvisintnntiadnsavensmancataueaeosdsveanntnes 7 Cep EN E E 7 Step 2 Connectivity Box 12 Step 3 AC Power Modlule 13 Step 4 Architectural Adapter Plates 14 Step 5 Completing the Installation 15 AVTrac Contents Ed TE 18 Reference Information 20 Optional Accessories s ssnnnoeeenenenoennnennnn 20 AVTrac Accessories ccccccecececececeavaeaeaeas 20 Audio Visual AAbe eren 20 V AVTrac Contents vi Introduction Overview This guide describes the AVTrac components and provides instructions for installation d EI Projector AVTrac Floor System Low profile Raceway System AVTrac is a low profile raceway sys
8. AC Power Modules Universal Outlet Conduit only 70 799 07 Rubber Inlay Kit 8 feet 2 4 m 70 670 01 Extra Channel Kit 70 671 01 Rough in Adapter 70 781 01 Wall Trim Plate 70 782 01 Raceway Transition Adapter Wiremold 70 783 01 Raceway Transition Adapter EU Channel 70 783 11 Retrofit Transition Adapter 70 679 22 Cable Pass through kit 70 714 02 Audio Visual AAPs Part Number Extender VGA QXGA Line Driver with Audio 70 147 12 PVT CV Composite Video and Stereo Audio Twisted Pair Transmitter 70 579 12 PVT RGB RGB Video and Stereo Audio Twisted Pair Transmitter 70 580 12 VGA Female to 5 BNC pigtail and 3 5 mm Barrel 70 551 71 RJ 11 Terminal Post and RJ 45 Female to Female Barrel 70 100 12 Two USB A Female to two USB B Female on 10 inch pigtail 70 382 12 One HDMI Female to one HDMI Female on 10 inch pigtail 70 616 12 Two RCA Female to Captive Screw Terminal audio one RCA Female 70 330 11 to Female Barrel video one S Video Female to Female Barrel Please consult the Extron website www extron com or catalog for a complete description of each item AV Trac Reference Information 20 Extrone Warranty Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase In the event of malfunction during the warranty period attributable directly to faulty workmanship and or materials Extron Electronics will at its option rep
9. This device must accept any interference received including interference that may cause undesired operation The Class A limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the user guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense NOTE This unit was tested with shielded cables on the peripheral devices Shielded cables must be used with the unit to ensure compliance with FCC emissions limits For more information on safety guidelines regulatory compliances EMI EMF compliance accessibility and related topics click here Notational Conventions Used in this Guide TIP A tip provides a suggestion to make setting up or working with the device easier NOTE A note draws attention to important information CAUTION A caution warns of things or actions that might damage the equipment Copyright 2010 Extron Electronics All rights reserved Trademarks All trademarks mentioned in this guide are the properties of their respective owners NF I B Contents Introduction E 1 OVENI ENESE enon E 1 AV Irac Floor System
10. ack 1 O 4feet 1 22 m side ramps 2 E Plastic wall base trim template 1 AVTrac Kit Contents 3 Before Getting Started Planning AVTrac can be installed before new carpeting is fitted or retrofitted under preexisting carpet It can also be installed in new construction before the drywall and carpeting is in place Retrofitting the track in a space with existing carpeting and furniture requires some extra preparation to remove the carpet and prepare the floor for laying the track Before installing the AVTrac determine whether the installation will be in new construction under preexisting carpet tiles or under preexisting carpet rolls and follow the appropriate installation instructions see page 7 Read and follow all instructions carefully Floor Considerations AVTrac is designed to be installed only underneath commercial grade carpeting 1 4 inch to 5 16 inch 0 6 to 0 8 cm in thickness It can be installed under new or preexisting carpet tile or carpet roll AV Trac is not designed to be installed under vinyl composite tile VCT To install AVTrac over most types of flooring consult the AVTrac Above Floor Installation Solution which is available on the Extron website In Wall Cable Routing Considerations Locate a convenient junction box in the wall or ceiling for power The AC power module is rated at 20 A maximum and no fuse is used on the box Extron recommends that the AC conduit be connected to a juncti
11. air or replace said products or components to whatever extent it shall deem necessary to restore said product to proper operating condition provided that it is returned within the warranty period with proof of purchase and description of malfunction to USA Canada South America Japan and Central America Extron Electronics Japan Extron Electronics Kyodo Building 16 Ichibancho 1001 East Ball Road Chiyoda ku Tokyo 102 0082 Anaheim CA 92805 Japan U S A Europe Africa and the Middle East China Extron Europe Extron China Hanzeboulevard 10 686 Ronghua Road 3825 PH Amersfoort Songjiang District The Netherlands Shanghai 201611 China Asia Middle East Extron Asia Extron Middle East 135 Joo Seng Road 04 01 Dubai Airport Free Zone PM Industrial Bldg F12 PO Box 293666 Singapore 368363 United Arab Emirates Dubai Singapore This Limited Warranty does not apply if the fault has been caused by misuse improper handling care electrical or mechanical abuse abnormal operating conditions or modifications were made to the product that were not authorized by Extron NOTE f a product is defective please call Extron and ask for an Application Engineer to receive an RA Return Authorization number This will begin the repair process USA 714 491 1500 Europe 31 33 453 4040 Asia 65 6383 4400 Japan 391 33511 7655 Units must be returned insured with shipping charges prepaid If not insured you assume the risk of loss o
12. ctivity conduit and accessory components e Boxes 2 and 3 contain the track and ramp components Check the contents of each box to ensure all items are present Double sided Tape 1 roll 5 32 Masonry Bit 1 and 3 16 Masonry Screws 20 AC Power Module 1 Installation Guide 1 HEN Connectivity Box 1 AN End Ramps 2 RK Cover AAP Plate for AC Power Module 1 Pre wired AC Power Flex Conduit 1 Rubber Strip 1 model 42 156 24A only Checklist for contents of box 1 Connectivity box 1 with 6 32 inch nut 1 to secure AC power module AC power module 1 prewired with 24 feet 7 32 m oval flex conduit 9 35 inches 23 7 cm quarter circle end ramps 2 Cover AAP plate for AC power module 1 Double sided adhesive tape 1 roll of 15 feet for rubber inlay strip 3 16 inch masonry screws 20 5 32 inch masonry drill bit 1 Installation guide 1 EI EI E EI E E E EB E 8 feet 2 44 m rubber strip 1 model number 42 156 24A only AVTrac Kit Contents Boxes 2 and 3 Check the contents of each box to ensure all items are present Side Ramp 2 Plastic Template 1 Aluminum Cover Track 1 Aluminum Base Track 1 Checklist for contents of box 2 O 4 feet 1 22 m aluminum base track 1 3 feet 0 91 m aluminum cover track 1 O 4feet 1 22 m side ramps 2 Checklist for contents of box 3 O 4feet 1 22 m aluminum base track 1 O 4feet 1 22 m aluminum cover tr
13. d Prelaid Carpet Tiles For installation of AVTrac under prelaid carpet tiles peel back the carpet to expose the concrete where the track and side ramps will be positioned as shown in the figure at right Prelaid Carpet Rolls Peel back Carpet If AVTrac is being installed in a room that is already fitted with carpet rolls the ideal solution is to peel back the entire carpet roll s covering the area where the track will run AVTrac Installation 7 Prelaid Carpet Rolls Cut Carpet When the positioning of preinstalled furniture makes it impossible to remove existing carpet the carpet must be cut see the figure at right Use tape to mark where the track and ramps will be positioned and make one straight cut in the middle of where the base track will run see the figure to the right This cut must be the same length as the base track Make three shorter cuts and corresponding to but extending about 4 inches 10 2 cm past the edges of the end ramps These cuts must be clean because the carpet needs to be seamed after the AVTrac has been installed Pull the carpet back to expose the floor where the base track the side ramps and the end ramps will be secured Side Ramps NOTE AVTrac is not designed to be installed under vinyl composite tile VCT 2 f necessary remove the baseboard from the bottom of the wall and mark where the AVTrac will meet the wall AVTrac e I
14. e sur l appareil Ce mat riel doit tre utilis avec une alimentation principale comportant un fil de terre neutre Le troisi me contact de mise la terre constitue un dispositif de s curit n essayez pas de la contourner ni de la d sactiver D connexion de l alimentation Pour mettre le mat riel hors tension sans danger d connectez tous les cordons d alimentation de l arri re de l appareil ou du module d alimentation de bureau s il est amovible ou encore de la prise secteur Protection du cordon d alimentation e Acheminer les cordons d alimentation de mani re ce que personne ne risque de marcher dessus et ce qu ils ne soient pas cras s ou pinc s par des objets R paration maintenance Faire ex cuter toutes les interventions de r paration maintenance par un technicien qualifi Aucun des l ments internes ne peut tre r par par l utilisateur Afin d viter tout danger d lectrocution l utilisateur ne doit pas essayer de proc der lui m me ces op rations car l ouverture ou le retrait des couvercles risquent de l exposer de hautes tensions et autres dangers Fentes et orifices Si le boitier de l appareil comporte des fentes ou des orifices ceux ci servent emp cher les composants internes sensibles de surchauffer Ces ouvertures ne doivent jamais tre bloqu es par des objets Lithium Batterie Il a danger d explosion s ll y a remplacment incorrect de la batterie Remplacer uniquement avec
15. f the carpet and the cover track Carpet covers ramps but not track AVTrac e Installation 15 4 Glue or tape the carpet to the floor and side ramps NOTE Do not use the supplied tape to attach the carpet to the ramp The tape is intended only for attaching the rubber inlay strip to the cover track 5 Using the provided template trim the wall baseboard to fit snugly around the track 6 Attach the baseboard to the wall 7 For model part number 42 156 24A attach the provided rubber strip to the cover track raceway using double sided adhesive tape provided For model part number 42 155 24A cut a strip of the finished carpeting and glue it to the cover track raceway AMTrac e Installation 16 The figure below shows a completed AVTrac installation which safely and discretely runs power data and A V cables from a wall to a table podium or other furniture AV Trac e Installation 17 Specifications General GWA ee 125 VAC 50 60 Hz 20 A max Mounting options Track system track and ramps Mountable onto base flooring beneath finished carpeting Connectivity DO Xd a Mountable through the metal track onto base flooring Optional AAP plates devices Mountable in the two double space and two triple space Architectural Adapter Plate AAP openings in the connectivity box Enclosure type ae e ie Track base and top metal Connectivity box plastic cover metal base Ramps plastic E
16. g der empfindlichen Teile im Inneren Diese Offnungen d rfen niemals von anderen Objekten blockiert werden Litium Batterie e Explosionsgefahr falls die Batterie nicht richtig ersetzt wird Ersetzen Sie verbrauchte Batterien nur durch den gleichen oder einen vergleichbaren Batterietyp der auch vom Hersteller empfohlen wird Entsorgen Sie verbrauchte Batterien bitte gem t den Herstelleranweisungen Advertencia Alimentaci n el ctrica e Este equipo debe conectarse nicamente a la fuente tipo de alimentaci n el ctrica indicada en el mismo La alimentaci n el ctrica de este equipo debe provenir de un sistema de distribuci n general con conductor neutro a tierra La tercera pata puesta a tierra es una medida de seguridad no puentearia ni eliminaria Desconexi n de alimentaci n el ctrica e Para desconectar con seguridad la acometida de alimentaci n el ctrica al equipo desenchufar todos los cables de alimentaci n en el panel trasero del equipo o desenchufar el m dulo de alimentaci n si fuera independiente o desenchufar el cable del recept culo de la pared Protecci n del cables de alimentaci n Los cables de alimentaci n el ctrica se deben instalar en lugares donde no sean pisados ni apretados por objetos que se puedan apoyar sobre ellos Reparaciones mantenimiento Solicitar siempre los servicios t cnicos de personal calificado En el interior no hay partes a las que el usuario deba acceder Para evitar riesgo de electrocuci
17. in the cover of the connectivity box with seven spaces of AAPs AC Outlet f Cover Plate In models without the AC power module fill all ten spaces of AAPS NOTE Extron AAPs must be purchased separately NOTE To prevent bending of cables place E the AAP with the greatest depth requirement including cables in the AAP slot closest to the center ridge of the connectivity box 3 55 9 02 cm 2 Run the cables from the wall to the connectivity box Attach the cables to the AAPs as described in the installation guide for each AAP module N i EE e Ee pm 3 Reattach the cover panel AVTrac Installation 14 Step 5 Completing the Installation At this point the track and connectivity box must be secured to the floor the electrical power must be connected and the AAP sockets must be populated To complete the installation of the AVTrac follow these instructions 1 Lay the cables and power cords flat against the base track If necessary feed excess cable back into the wall 2 Snap the cover track onto the base track 3 Before cutting and gluing carpet remove all dust and debris with a vacuum cleaner Cut the carpet or carpet tiles so that it runs up to but does not cover the aluminum track see the diagram below NOTE Cut the carpet to meet the edge of the cover track Do not align the cuts to the edge of the ramps because this will leave a gap between the end o
18. ithin 6 inches 15 2 cm of each end of the track Bi Base Track To ensure that all components are securely attached to the floor Extron recommends that the predrilled holes should closely follow the pattern shown in the figure below 6 inches max Le 3feetmax gt x 6 Remove the cover panel from the connectivity box Examine the bottom of the connectivity box one end has two mounting holes one in each corner the other end has three gees mounting holes one in each corner and one 3 mounting holes V mounting Holes in the center The end with three holes faces toward the track This end has 2 mounting holes Align the end of the box with two mounting holes with the end of the base track Mark where the mounting holes in the bottom of the box lie over the base track Using a 1 4 inch bit for drilling metal not supplied drill at least three mounting holes in the base track to secure the connectivity box to the floor AVTrac e Installation 10 7 Lay the base track on the floor in the Tab on side ramp mates with groove prepared location ee Mate the tabs in the side ramps with the j Side Ramp grooves in the base track and place the end Fork EN Base Track ramps in position at the end of the track furthest from the wall 8 Using the provided masonry bit drill Drill a 5 32 x 1 1 2 deep hole 5 32 inch diameter by 1 1 2 inch deep into concrete
19. nclosure dimensions see diagrams below Track system Steel 0 67 1 7 cm H x 9 36 23 8 cm radius approximately 4 5 slope Te 02 108 0 EEN 0 67 1 7 cm H x 7 50 19 0 cm W on either side of track x two 48 0 121 9 cm sections total 96 0 243 8 cm L approximately 4 5 slope Track base and top 1 03 Hx 3 70 W x two 48 0 sections total 96 0 L 2 6 cm H x 9 4 cm W x two 121 9 cm sections total 243 8 cm L AVTrac 482R 18 70 47 55 cm End Ramp Connectivity AAP Box b 3 55 9 02 cm LS A Side Ramp 9 36 S S Rubber Strip 23 77 cm SS included with Tae 00 N AVTrac 482R 30 48 cm i SX p PF AS Track 8 Total 2 44 m two 4 tracks TOP VIEW Eu I 2 91 7 39 cm 0 22 1 09 0 56 cm 2 61 cm Se el LS 4 5 0 67 1 70 cm L M n i P 19 05 cm 9 40 cm 19 05 cm BACK VIEW AVTrac Specifications 18 Connectivity box 3 55 Hx 4 27 Wx 12 0 L 9 0 cm H x 10 8 cm W x 30 5 cm L 12 00 30 48 E 4 27 10 84 TOP VIEW 427 J 10 84 ae E 3 55 9 02 Q Extrom
20. nstallation 8 3 Using a drill and box cutters or a saw cut a hole at the base of the wall 4 inches wide by 1 inches high 10 1 cm x 3 8 cm If there is a metal base stud use a hand saw or tin snips to cut it at both edges of the hole and bend it back into the hole so that the stud lies flat on the floor Use a file to remove any jagged edges that might damage cables The hole will eventually be covered by the baseboard so it does not have to be perfect 4 Measure and cut the track pieces to the desired length The track should run up to but not enter the hole in the wall WARNING Always wear safety goggles when using power equipment If the track is to be cut the base track must be 12 inches 30 48 cm longer than the cover track This is the length of the connectivity box which sits on the base track but not on the cover track see the figure at right The end ramps add an additional 9 36 inches 23 8 cm to the total length of the installed track qu 10 2 cm 1v 3 8 F d F Aluminum Cover Track Side Ramp 9 36 23 77 cm Aluminum Base Track AMTrac e Installation 9 5 Drill mounting holes in the shallow grooves of Shallow Groove the base track and side ramps using a 1 4 inch EEN Ve bit for drilling metal not supplied Shallow Groove in Side Ramp NOTE Mounting holes must be a predrill holes maximum of 3 feet 91 cm apart and one must be w
21. on box that is wired directly to a 20 A main circuit Cables should be run in walls that have drywall cavities The wall should be free of windows studs pipes or other obstructions that could hinder cable runs see the figure below LAN Window Projector Extron AVTrac Floor Mount Raceway System AVTrac Before Getting Started 4 Room Considerations Determine the A V requirements for the room Extron provides a complete range of AAPs that can be purchased separately to provide fully customizable central connectivity Select the best configuration for existing furniture equipment cables and the AVTrac It may help to mark the position of the track using a marker pen or tape The connectivity box must be positioned under a podium or table to avoid creating a tripping hazard AVTrac can be cut to meet the needs of the room For further details see step 4 on page 9 Optional track component extension kits are also available Cable Cubby Cable Cubby MediaLink Controller AV Trac MediaLink Controller Conference Room Classroom ADA Compliance The maximum slope of the AVTrac is 4 5 which fully complies with ADA requirements Refer to Title Ill Regulation 28 Code of Federal Regulations CFR Part 36 ADA Standards for Accessible Design Section 4 8 Ramps for full details Ramps Requirement The maximum slope of a ramp shall be 1 12 ratio 1 inch rise for each 12 inches run ap
22. osest to the track 6 32 Nut a Slide the power module side tabs into the AC Power Tabs bS slots on the side of the connectivity box noone E b Seatthe power module on the stud in the connectivity box C Secure the module to the stud on the connectivity box by hand tightening the provided 6 32 inch nut 2 Run the unattached end of the AC conduit through the wall cutout and connect it to a junction box inside the wall or ceiling Extron recommends the circuit be attached to a junction box that is directly wired to the main circuit The AC power module does not have a fuse and is rated at 20 A maximum WARNING Switch off all electrical power before connecting the AC conduit to a junction box and keep power off until installation is complete To20 Amp Main Circuit CAUTION All electrical installation should be performed by qualified personnel in accordance with Junction Box local and national electrical codes ground AC Conduit 4 From AVTrac AC Power Module AVTrac Installation 19 Step 4 Architectural Adapter Plates AAPs At this point the track ramps and connectivitly box must all be securely in place If an AC power module is required it must be attached to the connectivity box and connected to an AC junction box Do not turn on the power at this time To attach the Architectural Adapter Plates AAPs follow these instructions AAP 1 Fill the remaining AAP slots
23. pilot holes into the concrete through the Supplied Masonry Screws predrilled mounting holes in the track and T ramps wu uuu 9 Secure the track and ramps to the floor with the provided masonry screws NOTE Do not use the holes that were drilled to secure the connectivity box in sub step 6 of this section AVTrac Installation 11 Step 2 Connectivity Box By this point the base track side ramps and end ramps must be securely fastened to the floor To attach the connectivity box to the base track follow these instructions 1 Reposition the base of the connectivity box Mounting Holes 3 at the end closest to the wall in the correct orientation over the predrilled holes in the base track see sub step 6 in Step 1 Track Masonry Screws The end of the connectivity box that has three mounting holes faces back towards the wall 2 Using at least three of the provided 3 16 inch masonry screws secure the box to the track and floor 3 Remove all dust with a vacuum cleaner AVTrac Installation 12 Step 3 AC Power Module By this point the base of the connectivity box must be securely fastened to the floor If your AVTrac system does not include the AC power module ignore this section To attach the AC power module follow these instructions 1 The AC power module must be positioned under the triple AAP socket that is cl
24. proximately 4 8 The AVTrac maximum slope is 4 5 which meets ADA requirements AVTrac Before Getting Started 5 Tools and Equipment Required Before Installation Almost everything you need to install your AVTrac system has been included You will need some basic tools and materials depending on the facility and requirements Visit www extron com for a Tull range of cables and components for populating the connectivity box Tin Snips iter Cutoff Sa lade for cuttin etal AVTrac Before Getting Started 6 Installation Step 1 Track By this point you must have decided exactly where the AVTrac will be installed checked the contents of the kit and gathered the tools that you will need Extron recommends consulting a carpeting expert before removing the carpet 1 Determine whether the installation will be in new construction under preexisting carpet tiles or under preexisting carpet rolls and follow the appropriate instructions When installing AVTrac under preexisting carpet if possible completely remove the carpet from where the track will be laid If this is not possible the carpet must be cut After removing the carpet make sure that the concrete base is level and structurally sound Prior to installation leveling and topping may be needed New Construction When AVTrac is being placed in a new building the carpet should not be laid until the track has been installe
25. r damage during shipment Returned units must include the serial number and a description of the problem as well as the name of the person to contact in case there are any questions Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality performance merchantability or fitness for any particular use In no event will Extron Electronics be liable for direct indirect or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage Please note that laws vary from state to state and country to country and that some provisions of this warranty may not apply to you Installation Checklist Installation of the AVTrac can be divided into six main sections Before Getting Started O Open the three boxes containing the AVTrac kit and identify all the items provided pages 2 and 3 O Decide where the Track will be placed pages 4 and 5 and if necessary prepare the site O Gather any additional tools needed for the installation page 6 Step 1 Install Track O Remove the existing carpeting pages 7 and 8 Cut a hole for cables in the drywall page 9 oO O Measure and cut the track pieces pages 9 and 10 oO Secure the track to the floor pages 10 and 11 Step 2 Install Connectivity Box O Remove the top cover from the connectivity box and place the base on the track pages 10 through 12
26. rces This equipment should be operated only from the power source indicated on the product This equipment is intended to be used with a main power system with a grounded neutral conductor The third grounding pin is a safety feature do not attempt to bypass or disable it Power disconnection To remove power from the equipment safely remove all power cords from the rear of the equipment or the desktop power module if detachable or from the power source receptacle wall plug Power cord protection e Power cords should be routed so that they are not likely to be stepped on or pinched by items placed upon or against them Servicing Refer all servicing to qualified service personnel There are no user serviceable parts inside To prevent the risk of shock do not attempt to service this equipment yourself because opening or removing covers may expose you to dangerous voltage or other hazards Slots and openings If the equipment has slots or holes in the enclosure these are provided to prevent overheating of sensitive components inside These openings must never be blocked by other objects Lithium battery There is a danger of explosion if battery is incorrectly replaced Replace it only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the instructions of the manufacturer Avertissement Alimentations Ne faire fonctionner ce mat riel qu avec la source d alimentation indiqu
27. tem designed to safely and discretely run power data and A V cables from a wall to a table podium or other furniture The raceway system mounts directly onto the concrete floor and underneath the carpet AAP Compatible Connectivity Box The modular enclosure supports up to ten single space Extrone Architectural Adapter Plates AAPs with hundreds of connection options creating a fully customizable connectivity solution Models with the AC module accommodate up to seven single space AAPs AAPs are sold separately LAN Wiremold 4000 Series eon Extron Raceway Transition Adapter Extron AVTrac Floor Mount Raceway System for A V Connectivity Multiple Accessories The AVTrac system has a wide variety of accessories that provide adaptability and versatility to handle most installation requirements ADA Compliant The slope and rise of the side and end ramps comply with the Americans with Disabilities Act Standards for Accessible Design Title Ill Regulation 28 CFR Part 36 ADA Standards for Accessible Design Section 4 8 Ramps Choice of Finishes The AVTrac 482C accommodates commercial grade carpet inlay 1 4 inch to 5 16 inch 0 6 to 0 8 cm thickness in the aluminum raceway cover track The AVTrac 482R accommodates the included black rubber strip inlay as its top finish AVTrac e Introduction 1 Kit Contents Box 1 The AVTrac Kit is shipped in three boxes e Box 1 contains the conne
28. wenden Sie keine Werkzeuge oder Zusatzger te die nicht ausdr cklich vom Hersteller empfohlen wurden da diese eine Gefahrenquelle darstellen k nnen Instrucciones de seguridad Espanol AN A Precaucion Leer las instrucciones Leer y analizar todas las instrucciones de operaci n y seguridad antes de usar el equipo Este s mbolo se utiliza para advertir al usuario sobre instrucciones importantes de operaci n y mantenimiento o cambio de partes que se desean destacar en el contenido de la documentaci n suministrada con los equipos Este s mbolo se utiliza para advertir al usuario sobre la presencia de elementos con voltaje peligroso sin protecci n aislante que puedan encontrarse dentro de la caja o alojamiento del producto y que puedan representar riesgo de electrocuci n Conservar las instrucciones e Conservar las instrucciones de seguridad para futura consulta Obedecer las advertencias Todas las advertencias e instrucciones marcadas en el equipo o en la documentaci n del usuario deben ser obedecidas Evitar el uso de accesorios No usar herramientas o accesorios que no sean especificamente recomendados por el fabricante ya que podrian implicar riesgos ZEM e mx E IN Erem EE Ir E EE DG AAB Ir HI PD LP EO EPREDUE Ze DU HI An VRTrWLBHHR e HEAR AE DDT DR RR fH JiSpERE HP Rr nA sa EAT CRUS UH EIB IN e AREE HIA in ABCA EE A Bk ie Ice DORE TOES Warning Power sou
Download Pdf Manuals