1. Compact wall scanner is defective Replace the compact wall scanner Antenna of the compact wall scanner is defective Replace the compact wall scanner External antenna is defective Replace antenna Relay has already picked up Wait for the relay to drop out 12 2014 OPERTIS 19 Compact wall scanners eLOCK eXpress Installation and operating instructions Problem Possible cause Solution Transponder obtains no access Transponder is not programmed or does not have the necessary authorisations Program the transponder Compact wall scanner has wrong date or wrong time Reset the date and time Faulty data transmission with the NFC stick or the ToDo card Error during authorisation with the transponder Insufficient shielding of the connection cable to the antenna Use shielded cables and terminate the shield on connection4 GND of the compact wall scanner Each transponder is authorised for the lock Compact wall scanner is not programmed construction site mode Program the compact wall scanner see eLOCK eXpress Quick Start Guide Reset on authorisation or authorisation check Too much consumption in demand backlog at the bus For supply through POE Secure power supply for the antennas from elsewhere No optical or acoustic signalling at the terminal Signalling has been switched off in the
2. to ensure that the systems controlled by the compact wall scanner do not obstruct anyone at the passage entrance Note If a compact wall scanner is controlled by other external antennas the functional test must be performed separately for each antenna Proceed as follows Step Activity Result 1 Switch on power supply O Initialisation processes The compact wall scanner sets up communication with the connected antennas duration max 15 seconds Signalling to the antenna fast red flashing 1 short green flash O Standby mode Compact wall scanner in standby state Signalling to the antenna slow red flashing relay has not picked up Hold any OPERTIS transponder in front O Compact wall scanner s relays pick up signalling to the antenna 2 short red green flashes and a short high tone Example Activated door opens O After the connection time has expired Relay of the compact wall scanner drops out again Signalling to the antenna Short red flashing and short high tone Example Activated door closes 12 2014 OPERTIS 15 EN eLOCK eXpress Compact wall scanners Installation and operating instructions 7 Operation and Control Programming Terminals and Transponders Terminals and transponders are programmed using the eLOCK eXpress management software Optical and acoustic signals Note The signalling of the terminals depends on the settings in the eLOCK eXpress so
3. eLOCK eXpress software Switch on signalling in the software 20 OPERTIS 12 2014 eLOCK eXpress EN Installation and operating instructions Compact wall scanners 11 Product Specification Declaration of Conformity Konformit tserkl rung gem dem Gesetz ber Funkanlagen und Telekommunikationsendeinrichtungen FTEG und der Richtlinie 1999 5 EG R amp TTE Declaration of Conformity in accordance with the Radio and Telecommunications Terminal Equipment Act FTEG and Directive 1999 5 EC R amp TTE Directive ne OPERTIS GmbH e manufacturer Anschrift Prof Bier Stra e 1 5 Address 34454 Bad Arolsen Deutschland Germany erkl rt dass das Produkt Wandleser System declares that the product ES314 1000T ES314 1000U ES314 2000 ES314 2001 ES314 0001U Type Funkanlage Type Radio equipment Verwendungszweck Identifikation RFID 13 56MHz Intended purpose 7 lass 1 Gerateklasse Class Equipment class bei bestimmungsgem er Verwendung den grundlegenden Anforderungen des 3 und den brigen einschl gigen Bestimmungen des FTEG Artikel 3 der R amp TTE entspricht complies with the essential requirements of S3 and the other relevant provisions of the FTEG Article 3 of the R amp TTE Directive when used for its intended purpose Gesundheit und Sicherheit gem 8 3 1 1 Artikel 3 1 a Health and safety requirements pursuant to 3 1 1 Article 3 1 a angewendete harmonisierte N
4. the small slit above the connection cable and pull out the cable Remove the compact wall scanner from the flush mounted box 18 OPERTIS 12 2014 eLOCK eXpress Installation and operating instructions EN Compact wall scanners 10 Problems and Solutions Note Problems and solutions that can occur during or due to connected components e g antennas are described in the respective installation instructions Problem Possible cause Solution Transponder is not recognised no positive or negative acknowledgement Transponder is defective Replace transponder Compact wall scanner is defective Replace the compact wall scanner Peripheral device does not respond Relay of the compact wall scanner is defective Replace the compact wall scanner Peripheral device has no power supply Switch on the power supply of the peripheral device Peripheral device is connected incorrectly Correct connection Peripheral device is defective Replace peripheral device Connection cables are defective Replace connection cables Antenna has no ready signal Power supply is defective or not connected Ensure power supply Connection cable to the antenna is defective or not connected Ensure connection to the antenna Operating voltage not within the allowable range Connect correct power supply voltage
5. tool 12 2014 OPERTIS 11 EN eLOCK eXpress Compact wall scanners Installation and operating instructions 6 Installation Overview The installation is divided into the following activities O Connecting the cables O Functional test CAUTION Unauthorised access following installation In the as delivered condition the compact wall scanner is in construction site mode Access is possible with any OPERTIS transponder even if not programmed Immediately following installation you should program the authorisations to prevent unauthorised access refer to the eLOCK eXpress Quick Start Guide Have the date and time reset if necessary by your eLOCK eXpress trade partner Installation Tools Required You will need the following tools for the installation O Suitable screwdriver for installing screws available on site O Cable strippers or side cutters for stripping off the insulation and shortening the connection cable 12 OPERTIS 12 2014 eLOCK eXpress EN Installation and operating instructions Compact wall scanners Connecting the cables Proceed as follows Step Activity Figure 1 All the necessary connection Rear view of the compact wall cables are connected to the scanner UP controller see Pin Assignment table 2 The remaining installation sequence is described in the respective installation instructions of the wall scanner cover or the wall scanner housing 3 The
6. 1 5 1 Other means of proving conformity with the essential requirements standards interface specifications used Phone fax e mail Tel 49 5691 87741 0 Fax 49 5691 87741 310 S i info opertis de AZ Fl f lf ur a T a e s d jf wg Bad Arolsen 2014 05 12 Andreas Steinkamp f Ort Datum Gesch ftsf hrer CEO Place amp date of issue Name und Unterschrift Name and signature 22 OPERTIS 12 2014 eLOCK eXpress EN Installation and operating instructions Compact wall scanners Dimensions All dimensions given in mm Rating plate ES314 0001U Compact wall scanner OPERTIS Serial number 12345 12345 OPERTIS GmbH HW AA FW D E F Prof Bier Stra e 1 5 MAC 00 11 22 33 44 55 D 34454 Bad Arolsen Supply voltage i 12 24V DC max 500mA C RX or Made in Germany Power over Ethernet Class 0 Bitte Installationsanleitung beachten Please note installation instructions Note on the Operating System The compact wall scanner is operated with the FreeRTOS operating system Further information under www freertos org 12 2014 OPERTIS 23 EN Compact wall scanners eLOCK eXpress Installation and operating instructions Technical data Installation environment Installation depth 244mm Installation diameter 2 53 mm or standard flush mounted boxes with 60 mm fixing spacing Installation distance between antennas Power supply connections Power
7. OPERTIS Installation and operating instructions Compact wall scanners ES314 0001 U EN eLOCK eXpress Compact wall scanners Installation and operating instructions Contents 1 Introduction eme 4 About these instructions Heeres ueis ntiesieren 4 Explanation of the symbols and signal words USEGC c ccccceeeceeeeeeeeeeeeeeeeeeeeeeeees 4 MAES OWI TREE E 4 OPERTIS SHDDOLPL anstehen c vei OP Rd EX 4 Up to date information uu oso exten eaae nde ttn cox orav ance Lau ee dor on ex ea du 5 2 Product Description esses exuxa i exkk ark n io cc oo oc o RC OE ER nnk 5 FIV CN NIE We de e ee dA AT aga sean ane Ad E 5 Operating FING IOI Sin een een erde 6 Signalliigisstuo demit e PNEU edi ur md i d dee fep Ceu ENDO nq Pe fU atr 6 Detailed Informatio caecos vae a CERE ee ONU reg Mr ha veu ORUM 6 3 Intended US 7 PCA OUS Iis codg ate tot heu vot item nes Le E Ie ndis noes eA Opis Voted te SCEE NENNE Nb RI pdpr cot HERSENEE RE 7 Condition of the DEOGOLICE ans seen eh 8 Atmbient CondlllOliS coca rcd t Lice i e P en ear eiie e deii Qa ated ee 8 Residual RISK iioc eee noa teu tear ro A et oeque audi feta teme ut ieee 9 4 Safety Instructi nS siiin nn 10 Miis DuEDdqM 11 6 Installation aan RD RIAM REIN IRL IAN IARE 12 OVEIVIEW RR Pu EB pnt RR IR ien Go a 12 Installation Tools Regul G eoe racer Cena Cir t xi
8. connected devices for example door openers 12 2014 OPERTIS 9 EN eLOCK eXpress Compact wall scanners Installation and operating instructions 4 Safety Instructions A The following safety instructions must be noted and followed before use OPERTIS does not accept any liability whatsoever for personal injuries or damage to property caused by failure to follow these instructions WARNING Risk of personal injuries and damage to property There is an increased risk of injuries electric shock if the compact wall scanner or the connection cables are touched while the power supply is switched on The compact wall scanner and or the connected peripheral device can be irreparably damaged Do not carry out any installation or maintenance work unless the power supply is switched off Note and follow the VDE guidelines VDE 0100 CAUTION Risk of personal injuries and damage to property Risk of fire due to overheating of the E opener If activated by the fire service transponder the E opener is actuated continuously If E openers are used they must be designed for continuous actuation CAUTION Risk of being locked in or out Peripheral devices cannot be controlled without a functional compact wall scanner During installation of the wall scanner it is necessary to ensure that the systems controlled by the compact wall scanner do not obstruct anyone at the passage entrance CAUTION Risk of malfunctions Ma
9. er specific types are available in the eLOCK locking system for authorisation at the terminals These must be held in front of the antenna for authorisation checking Signalling The signalling of the terminals depends on the settings in the eLOCK eXpress software Optical signalling is switched on by default A buzzer can be switched on optionally for the acoustic signalling The additional power consumption for the buzzer reduces the number of locking cycles that can be achieved by battery operated terminals Detailed Information Further information on the product is given in Section 11 Product specification 6 OPERTIS 12 2014 eLOCK eXpress Installation and operating instructions EN Compact wall scanners 3 Intended Use Area of use The compact wall scanner is designed to control peripheral devices for example electric door openers electric locks motorised bars holding magnets electrical door and gate drives barriers lifts letter boxes etc The compact wall scanner is suitable for installation in flush mounted boxes in the protected interior of the building surface mounted installation is also possible with special spacer frames Combinations of the wall scanner products Note The protected outdoor area is an area which is free from splashed water in all directions Product Area of use TS controller UP controller Suitable for use in the protected indoor area Antenna in conjunc
10. ftware Optical signalling is switched on by default A buzzer can be switched on optionally for the acoustic signalling All optical and acoustic signals are given in the eLOCK eXpress system documentation In case of certain system states and events the wall scanner emits acoustic and or optical signals Optical signal Meaning 2x short blue blue1x short Programming with the ToDo card completed green successfully 2x short blue blue2x short Programming with the ToDo card not red red completed successfully 2x short blue blue1x short No programming job with the ToDo card red exists for the terminal repeated short blue Programming in progress with the NFC stick 2x short green blue Use of the security card 2x short green green Switching on of fitting by an authorised transponder 2x short red red No switching on of fitting transponder is not authorised 2x short red green Switching on of fitting in construction site mode continuous short red Wall scanner is ready for use standby 2x short red red System error contact sales partner 4x long yellow continuous short yellow The fire service transponder has been used 16 OPERTIS 12 2014 eLOCK eXpress EN Installation and operating instructions Compact wall scanners 8 Maintenance Cleaning and Care Intervals Maintenance and cleaning may only be carried out by qualified personnel We do not provide any warranty what
11. installation and connection of external components e g external antenna are described in the respective installation instructions Connection diagram ji Door opener Controller EE power pack power power c External antenna Controller pack cn Electromechanical door opener provided on site 12 2014 OPERTIS 13 EN Compact wall scanners eLOCK eXpress Installation and operating instructions Pin assignment Connection Description DC Power supply GND Power supply Out1 Relay 1 NO contact maximum 60V 1 6A Out1 Relay 1 NO contact maximum 60V 1 6A Bus 1 Connection of external devices VCC for antenna Bus 2 Connection of external devices RS 485 bus Bus 3 Connection of external devices RS 485 bus Bus 4 Connection of external devices GND for antenna In 1 Not used In 1 Not used In 2 Not used In 2 Not used Out 2 Not used GND Not used Out3 Not used GND Not used Connection Description 8 PoE 7 PoE 6 PoE 5 PoE 4 PoE 3 PoE 2 PoE 1 PoE 14 OPERTIS 12 2014 eLOCK eXpress Installation and operating instructions EN Compact wall scanners Functional test A CAUTION Risk of being locked in or out Peripheral devices cannot be controlled without a functional compact wall scanner During the functional test of the wall scanner it is necessary
12. ive gases or extreme temperatures is not allowed O Note In general avoid laying the cables in the immediate vicinity of noise sources Always use a shielded cable in ambient conditions with EMC disturbance To ensure reliable shielding it is advisable to terminate the control shielding to GND If you have any questions please contact OPERTIS Support 8 OPERTIS 12 2014 eLOCK eXpress EN Installation and operating instructions Compact wall scanners Residual Risk If used as intended and in compliance with the maintenance instructions this product will help to maintain your property security However the following residual risks cannot be excluded O If the mains voltage fails there is a risk of being locked in or out In this case it is only possible to open the door using mechanical tools Especially if installed in escape routes ensure that they can be passed through at all times O If the electronics fail there is a risk of being locked in or out It is then only possible to open the door using mechanical tools In this case contact OPERTIS support O If a compact wall scanner is used for access control to a fuse box there is a risk of being locked in or out if a fuse is defective It is then only possible to open the door using mechanical tools O OPERTIS recommends the use of an uninterruptible power supply UPS to ensure operation of the Compact wall scanner during a power failure and to ensure operation of the
13. lfunctions can occur if the compact wall scanner is installed in the immediate vicinity of alternating electromagnetic fields e g transformers MRI scanners etc and transmission equipment Before installing check whether any of the above mentioned interference factors could affect the function of the compact wall scanner 10 OPERTIS 12 2014 eLOCK eXpress EN Installation and operating instructions Compact wall scanners A CAUTION Risk of personal injuries The compact wall scanner is fitted with an LED which has a very bright light Ifthe compact wall scanner is supplied with voltage without a cover cap in front of the antenna the LED can dazzle Do not look directly into the light ofthe LED CAUTION Risk of manipulation When using a compact wall scanner if the controller is removed the exposed connection cables can switch the peripheral device Compact wall scanners should not be used for security relevant applications Instead a controller ES314 1000U ES314 1000T should be installed in the secured interior and an antenna ES314 2000 ES314 2001 installed on the security relevant access side CAUTION Risk of damage to property Electronic components can be irreparably damaged if touched Note and follow the regulations and instructions in the EN 61340 5 1 standard 5 Scope of supply The scope of supply includes the following parts Part Name Compact wall scanners ES314 0001U Unlocking
14. nh iR Cep rette cep dude ed 12 COANSCUNGMASCADISS s osdsoenc schon a a en in NER E RR 13 Funetllionaltest se 15 T Operation ANG Control 16 Programming Terminals and Transponders essen 16 Optucal and aceusuc SIGH ALS teet iota een 16 8 Maintenance Cleaning and Care unnuuuuuunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 17 IESG MEL 17 Cleaning and Gate E 17 Maintenance reelle 17 9 Dismantling issiria riei iara iaasa aha 18 10 Problems and SOM ONS iicicciscccscccccccnccsxcccncccnecencvccevencvexedencvecevencvecedencvexevencvexedeacvns 19 AT Rroduct Speeificauon sicisnirssasatiristiubintiaiatanieadeiiainetatiaiasdebistantaniriaadabagsontuaiaaiaakantans 21 Declaration of Conformity re ee 21 DIMENSIONS siesena oa EEEE EEE EEE EU AEE EEE OEE ETETE ATEEN 23 Rating plate innean a ee 23 Note on the Operating System ia ka diia 23 Technieal data zes see er ehe 24 2 OPERTIS 12 2014 eLOCK eXpress EN Installation and operating instructions Compact wall scanners IAE DISPOSAD mmm 27 gi o1 LE GE PERPE ee ee de een 27 Product packaging essssssssssesessseeseseeeeenenene nnne enne nnne n hn nenne nennen nan 27 erc RI eier 27 12 2014 OPERTIS 3 EN eLOCK eXpress Compact wall scanners Installation and operating instructions 1 Introduction About these instructions These instructions contain important information and instructions for installation o
15. ormen Harmonised standards applied Einhaltung der grundlegenden Anforderungen auf andere Art und Weise hierzu verwendete EN 50364 201 N Standards Spezifikationen EN 60950 1 2006 A11 2009 A1 2010 Other means of proving conformity with the essential A12 2011 requirements standards specifications used 12 2014 OPERTIS 21 EN eLOCK eXpress Compact wall scanners Installation and operating instructions Schutzanforderungen in Bezug auf die elektromagn Vertr glichkeit 3 1 2 Artikel 3 1 b Protection requirements concerning electromagnetic compatibility 8 3 1 2 Article 3 1 b angewendete harmonisierte Normen Harmonised standards applied Einhaltung der grundlegenden Anforderungen auf andere Art und Weise ETSIEN 301 489 3 v 1 4 1 hierzu verwendete Standards Spezifikationen Other means of proving conformity with the essential requirements standards specifications used Ma nahmen zur effizienten Nutzung des Funkfrequenzspektrums Measures for the efficient use of the radio frequency spectrum Luftschnittstelle bei Funkanlagen gem 3 2 Artikel 3 2 Air interface of the radio systems pursuant to 3 2 Article 3 2 angewendete harmonisorte Normen Einhaltung der grundlegenden Anforderungen auf andere Art und Weise hierzu verwendete ETSI EN 301 330 1 v 1 7 1 Sm Standards Schnittstellenbeschreibungen ETSI EN 301 330 2 v
16. peration of the eLOCK eXpress Compact wall scanner O Read through the instructions carefully before starting the installation work and putting into service O Keep the instructions in a safe place and pass them on to each subsequent user of the compact wall scanner Explanation of the symbols and signal words used AN WARNING Indicates hazards which could result in severe or fatal injuries CAUTION Indicates hazards which could result in minor or moderate injuries Indicates hazards which could result in damage to CAUTION property Indicates information and tips for optimum use of the mole instructions and the product Target group Faultless and safe function of the compact wall scanner largely depends on proper installation These instructions are therefore directed at competent personnel who have completed suitable training or have experience appropriate for installation maintenance care disposal and maintenance of wall scanners or comparable products OPERTIS Support If you have any questions which are not answered by the information provided in these instructions please contact OPERTIS GmbH Prof Bier Stra e 1 5 D 34454 Bad Arolsen Tel 49 5691 87741 200 Fax 49 5691 87741 281 Email support opertis de 4 OPERTIS 12 2014 eLOCK eXpress EN Installation and operating instructions Compact wall scanners Up to date information All details of the product images dimensions and ve
17. rsions are correct at the time of delivery of the product We reserve the right to make changes in line with technical progress and the resulting continuous improvement process of our products The current version of these instructions and further information is also available on our internet site www opertis de Dated 12 2014 2 Product Description Overview These instructions describe the following controller Art No Name Drawing ES314 0001U Compact wall scanners 12 2014 OPERTIS 5 EN eLOCK eXpress Compact wall scanners Installation and operating instructions Operating principle The OPERTIS eLOCK eXpress locking system ensures continuous consistent fitout of a building Special terminal devices are available for different door types The Compact wall scanner can be combined with different OPERTIS cover caps and housings and operated with an external power supply or PoE The Compact wall scanner consists of a UP controller and an antenna Therefore no other antenna is required However it is possible to connect up to 3 other antennas to the compact wall scanner Interfaces are available for controlling external relays or peripheral devices The management and programming of the terminals including the issue of access authorisations is carried out using the eLOCK eXpress management software Various types of passive transponders without their own power supply such as key fobs and cards or custom
18. soever for damage caused by improper handling Activity Interval Maintenance 1 year Cleaning and Care Care and cleaning are not necessary for the compact wall scanner Maintenance A CAUTION Risk of being locked in or out Peripheral devices cannot be controlled without a functional compact wall scanner O During the functional test of the wall scanner it is necessary to ensure that the systems controlled by the compact wall scanner do not obstruct anyone at the passage entrance The following functional tests are to be performed once a year if necessary by the eLOCK eXpress trade partner Step Activity Result 1 Hold an authorised OPERTIS The connected peripheral transponder in front ofthe device opens for the duration connected compact wall of the defined opening time scanner The antenna signals as described above see Acoustic and optical signals section 2 Reset the date and time 12 2014 OPERTIS 17 EN Compact wall scanners eLOCK eXpress Installation and operating instructions 9 Dismantling Note Dismantle in the reverse order Proceed as follows Step 1 Activity Dismantle the wall scanner cover or wall scanner housing see separate installation instructions Figure Remove connection cables of network PoE Press respective button and remove the connection cable Remove remaining connection cables Insert the unlocking tool in
19. supply at least 100 mm in 3D space Automatic detection O 12 24 V DC unstabilised 10 or O PoE The compact wall scanner must be supplied from an electricity source with limited power according to EN 60950 1 2001 Antennas O A maximum of 3 external antennas can be connected to one compact wall scanner Length of the connection cable of antennas lt 300m connected in series Power consumption Depending on the number of antennas connected 0 externally connected antennas 1 8 W 1 externally connected antenna 2 0 W 2 externally connected antennas 2 2 W 3 externally connected antennas 2 4 W 24 OPERTIS 12 2014 eLOCK eXpress Installation and operating instructions EN Compact wall scanners Interfaces O Connection for antennas O Connection for an LAN network O Connection for control of external relays Outputs O 1 relay output Photomos NO contact O Control of the external relay ES0532U with two electromechanical changeover contacts Contact rating Relay contact NO max 60 V AC DC 1 6 A Connection cable Single wire 0 24 1 5mm Stripped length 6 0 9 0mm For details see Cable diagram section Network connection cable Single wire 0 14 0 5mm Stripped length 9 0mm Pin assignment Specific data Operating temperature see Section 6 Installation 20 C to 55 C Storage temperature 40 C to 85 C H
20. tion with cover cap 80x80 Spacer frame low optional Suitable for use indoors or in the protected outdoor area Antenna in conjunction with cover cap 80x80 Spacer frame IP65 Suitable for use outdoors Antenna in conjunction with cover cap 55x55 Suitable for use indoors or in the protected outdoor area Siedle antenna in built in frame of a Siedle Vario or Compact series door intercom system Degree of protection to EN 60529 IP54 UP controller Compact wall scanner in conjunction with cover cap 80x80 Spacer frame high optional Suitable for use indoors or in the protected outdoor area UP controller Compact wall scanner in conjunction with Surface mounted on wall housing IP65 Suitable for use outdoors 12 2014 OPERTIS 7 EN eLOCK eXpress Compact wall scanners Installation and operating instructions Product Area of use UP controller Compact wall Suitable for use indoors or in the scanner in conjunction with protected outdoor area cover cap 55x55 Compact wall scanner If using the individual antenna and UP controller components refer to the information above Condition of the product Compact wall scanners may only be used if they are in faultless technical condition Independent modifications and changes to the product are not allowed Ambient conditions O Use in particularly harsh environments with conditions such as aggress
21. umidity for operation and storage max 95 non condensing Degree of protection to EN 60529 IP20 12 2014 OPERTIS 25 EN eLOCK eXpress Compact wall scanners Installation and operating instructions Cable plan The defined cable types are not a mandatory specification merely a recommendation Antenna X J Y St Y 4x0 6 or CAT5 Preassembled CAT 5 cable External relay for 2 installation in flush mounted boxes LI su Power pply unit Mains voltage 230 Volt S 26 OPERTIS 12 2014 eLOCK eXpress EN Installation and operating instructions Compact wall scanners 12 Disposal Product Disposal in accordance with WEEE Directive 2012 19 EC O Do not dispose of product in the local household waste O Send product back to OPERTIS or dispose of it at a communal collection point for hazardous electronic wastes Product packaging The product packaging must be disposed of through the local household or paper waste collection facility Notes 12 2014 OPERTIS 27 OPERTIS Germany OPERTIS GmbH Prof Bier Stra e 1 5 34454 Bad Arolsen Telephone 49 5691 87741 200 Telefax 49 5691 87741 310 support opertis de www opertis de Ce MB314 03EN V001 12 2014

Download Pdf Manuals

image

Related Search

Related Contents

OlenCom Electronics. FM-16-9 Fiber Optical Mux UserManual  Latchways Personal Rescue Device™  User's Manual  取扱説明書  Mode d`emploi F2 CHROMO PROGRAMME - francepool  Brasil - Genius  ScreenCorder 5 PDF  Philips AVENT SCF784  PZ217E User Manual E-545 PInano® Piezo Controller Release: 1.2    

Copyright © All rights reserved.
Failed to retrieve file