1. 11 User selectable functions You can customise some of the functions of your pager to suit your own requirements This can be done at any time The following is a complete list of the functions You will only see those functions made available to you when your pager was configured Several functions are set as configuration defaults in the factory The headings for these are in normal text The remaining functions are shown in italics The user functions are shown on the TOP display The front display will show the last received message if any information To change the setting of a function press whilst it is shown on the display Each time you press the button the setting will change If you do not press the button for a short while the pager will move to the next function To access the selection mode Press and hold button Cf until the individual code is displayed then release it Display orientation MEES Cee Silent mode Long ID rr Ty PON TT LA LUING L Bleep volume HT Vol rr iri L vL LU v UL 12 The pager will show the available functions in sequence Press button f only if you wish to make a change This inverts the display to make it easier to read wherever you wear your pager You can stop your pager from bleeping whilst receiving a call If you select SILENT
2. 20 C lt Ta lt 40 C OCE amp m1 0889___1180 Battery option alkaline 4 Serial no XXxXxxx N RX XXXXXXMHz Chn xxkHz Type APG7 R Y 0 M x00 MAX CONTACT RATING Ui 20V li 40mA CONNECT ONLY IN A SAFE AREA FOR CELL TYPE SEE CERTIFICATE THIS UNIT MUST BE FITTED INTO ITS POUCH WHEN USED IN HAZARDOUS AREAS BLICK EXETER UK MODEL APG7 R T3 CERT No BASO1 ATEX xxxxx EExialICT3 20 C lt Ta lt 40 C Battery option NiMH Blick Pt No 151026 must be fitted Temperature rating CE Eme 0889 1180 Contents Introduction 4 How to use this guide 5 To prepare your pager for use 5 To insert or change the battery 5 Pager Controls 6 To switch your pager on 6 To reprogram your pager with identity codes Individual IC or Group GC 7 To use your pager 9 To receive paging calls 9 To change the top display orientation when in a charging rack 9 Low battery 10 Out of range 10 To review and delete stored messages 10 Block message review 10 Individual message review II User selectable functions 12 To configure your pager 13 To replace the clip 20 Glossary of paging terms 22 Introduction APG1 and APG2 pagers are designed for use in both on site and wide area paging systems The robust plastic case is fitted with a removable clip that allows the pager to be worn on a belt or in a pocket A safety cord with clip
3. Whilst pressing the clip towards the pager body rotate it anticlockwise by 90 and gently pull it away from the case 20 The thumb pressure avoids placing too much strain on the clip mounting To fit the new clip hold it 90 to the pager case and insert it into the aperture Lift the locking tab and whilst applying pressure and rotate the clip clockwise until it clicks into position information Never rotate the clip without lifting the tab as you will damage the case Please note Under certain circumstances your pager can be subjected to electrostatic discharge This can cause the unit to reset and go through the start up sequence before returning to normal operation 21 Bleep Group Code Individual Code Pager configuration Pager programming Open channel Glossary of paging terms Used to describe the sound made by a pager when called also bleep tone bleep sound A number shared between pagers allowing them to be called simultaneously A number representing the unique identity of a pager allowing it to be called selectively The process of selecting those pager functions that will be available to the user This normally forms part of system commissioning The procedure required to enter or change pager identity codes individual and group A diagnostic mode that allows a pager to receive all calls transmitted on a system and display
4. encoder The default Spee Code from the system encoder setting is C The display shows a number between O and 8 which indicated The pager will accept a maximum tha numberornon corectabla When the new code appears release the button of 6 group codes errors that are permissible in each ERRORS error level message block before a message is rejected as unusable If a message F is rejected in this way the call is The pager will show the Group Codes GC in sequence disregarded and the pager does not respond Corrupted characters are shown as blanks To add a Group Code press Ff while it is displayed Select this option to allow the user LONG ID long bleep to choose either the normal bleep time 5 s or a long bleep time 24 s Send a programming call from the system encoder This will save the settings t This is an engineering function onl BITSPRE decode algorithm E ERA E E 4 When the new code appears release the button The display will change to show the next Group Code This screen will allow you to set the default message review facility Select a tick to default to BLOCK MESSAGES or a cross to default to INDIVIDUAL MESSAGES You can _ BLKMESS temporarily change the setting from If you wish to add another Group Code press f and i the user selectable functions page A p default message review method 9 If you switch the pager off it will send a programming call r
5. is also supplied The APG1is an alphanumeric pager The APG2 is an alphanumeric pager that can receive speech messages where the system licence allows Pagers have a memory that can store up to 80 characters Messages are displayed in blocks of eight characters and can be reviewed and deleted when required The display can be inverted by the user so that messages are legible whichever way round the pager is worn The operational prompts may be displayed in any of six languages Fourteen different bleep tones are available Two volume levels or silent operation can be selected A light flashes during the call Each pager can be programmed with up to seven different addresses The first address is the pager s Individual Code number and the remaining six are Group Codes Each Group Code can be allocated to any number of pagers to allow them to be called simultaneously Addresses may be entered or changed by sending special programming calls to the selected pager The pagers are powered by one AA size cell battery this can be either disposable or rechargeable A rechargeable cell will be charged when the pager is placed in a charging rack A low battery indication is made on the pager s display when cells require replacement or recharging Vibrator optional A display back light How to use this guide To perform the required task simply follow the paragraphs in the left column To give you f
6. Blick g userguide Intrinsically safe pager type APG7 APG7 INTRINSICALLY SAFE PAGER LIMITATIONS OF USE This page contains BASEEFA related information No alterations are permitted without reference to the BASEEFA liason officer THE APG7 SERIES OF MOBILES ARE INTRINSICALLY SAFE AND MUST NOT BE MODIFIED WITHOUT PRIOR PERMISSION FROM THE CERTIFYING BODY Classification Category 1 Rating ia zone O Temperature rating See below Suitable for all gas air flammable mixtures except carbon disulphide IP rating protection level against the ingress of dust and liquid 53 Main case material ambient temperature range 20 C to 40 C The polycarbonate material used to manufacture the main case together with the natural leather pouch have been selected to protect the equipment against damage e g being dropped or knocked during normal operation These units contain no user serviceable parts other than the battery Units must be returned to the factory for servicing Important The pager must be fitted into its leather pouch when used in hazardous areas Serial no XWX A RX XXXXXXIMHz Chn xxkHz Y O M XxX Type APG7 D MAX CONTACT RATING Ui 20V li 40mA CONNECT ONLY IN A SAFE AREA FOR CELL TYPE SEE CERTIFICATE THIS UNIT MUST BE FITTED INTO ITS POUCH WHEN USED IN HAZARDOUS AREAS Blick Pt No 151015 must be fitted BLICK EXETER UK MODEL APG7 D CERT No BASO1 ATEX xxx Temperature rating T4 EExialICT4
7. When the displays go blank release the button To switch your pager on Press and hold Q until the displays show two crosses Release the button information The function button F When your pager was configured a number of user selectable functions were enabled You can access these using this button whilst in the selection mode please refer to the section User selectable functions for i Power details on off When you enter the selection mode the screen on your AU pager will show the available functions in sequence Each option is displayed for a short period before changing to function Bs the next Whilst a function is displayed it can be button f P switched between the settings by pressing button f L message Functions that can be switched on or off are selected when a tick 3 is shown and deselected by a cross X If alternative settings are offered then the text indicates the choice e g HIGH VOL or LOW VOL Message button This button controls message review You can press to cancel the bleep tone whilst receiving a call To reprogram your pager with identity codes Individual IC or Group GC You will need to be able to send programming calls from your paging encoder keyboard to carry out this procedure Please refer to the encoder user guide for details Press and hold button Ff until the top display shows the pager s current Individu
8. al Code Release the button Wait until the display shows PROGRAM then press and release f The display will first show PROGRAM and then the Individual Code To change the Individual Code press and hold button O while it is displayed Send a programming call from the paging encoder When the new code appears release the button The pager will show the Group Codes GC in sequence To add change or delete a Group Code press and hold F while it is displayed Send a programming call from the paging encoder When the new code appears release the button The display will change to show the next Group Code If you wish to add change or delete the code press and hold and send a programming call If you do not wish to make changes do not press the button and allow the pager to return to normal operation 8 i information IMPORTANT BEFORE PROGRAMMING YOUR PAGER PLEASE ENSURE THAT YOU FIT A NEW OR FULLY CHARGED BATTERY FAILURE TO DO SO MIGHT RESULT IN LOST CODES The display will scroll through the user selectable options e g display silent volume before reaching PROGRAM The current Individual Code will be shown for example I leem The display will show FF to indicate that your pager has returned to normal operation To use your pager To receive paging calls When your pager receives a c
9. all it will bleep and display a message and vibrate The display will show BLEEP SPEECH or a message Press the message button if you wish to cancel the bleep tone whilst receiving the call After you have received a message call you will offered the option to If you do not wish to save the message momentarily press J ami If you do nothing your pager will store the message The message will remain on the display until you receive another call information MESE mi BLEEP indicates that there is no message The sound of the bleep tone selected by the system operator is normally chosen to indicate the action that you should take SPEECH available on APG2 pagers indicates that a speech message is about to be transmitted When the bleep tone has finished you will receive the speech message To change the top display orientation when in a charging rack To alter the orientation of the display press button during the first second of entry into the rack The selection remains in the memory Low battery When fli HATT is displayed you must replace or recharge as appropriate the battery as soon as possible information Out of range If this option was selected during configuration your pager will bleep and display RANGE if you are out of range of the transmitter for more than 40 seconds l NOTE You mus
10. de If you wish to add another code press H and send a programming call If you do not wish to make changes do not press the button and allow the pager to return to normal operation information This will store the new code This will store the new code To configure the pager and program the identity codes Switch the pager off Press and hold button F then switch the pager on The pager will display the software title for example 16 IMPORTANT Please ensure that the battery is fully charged rechargeable or new disposable before programming the identity codes otherwise they might not be saved to memory To change the setting of a function press F whilst it is shown on the display Each time you press the button the setting will change If you do not press the button for a short while the pager will move to the next function then after a short while the first 8 function codes shown in the table for example Release the button to reveal those remaining for example The pager will now show the available function options in sequence Press button H only if you wish to make a change LANGUAGE The language options are automatically shown in sequence When your required language is displayed press and release button f SILENT RANGE LED Light POWER Continued on next page 17 informat
11. es are reviewed the display will be illuminated automatically The default message review method is set during pager configuration p13 If you select the alternative then your pager will revert to the default when you next switch it on Block message review User selectable option Press the message button to display the number of stored messages i 10 When no messages are stored then the displays will show 0 M Individual message review User selectable option Press the message button to display the number of stored messages Press the message button again to display the individual message number starting with the oldest Hold the button in to scroll through the message numbers Release the button when the message that you wish to see is shown When the message has been shown you will be offered the option to delete it pan Press the message button 9 momentarily if you wish to delete the message i NOTe If you switch your pager off or place it in a charging rack rechargeable batteries only all messages will be deleted The display will show J M o M The display will show EE E The display will show OF e The display will show MEREMERE The display will show iel e EN NOTE If you switch your pager off or place it in a charging rack rechargeable batteries only all messages will be deleted
12. evert to the default setting the next Block message review allows all the messages in the time that it is switched on store to be read at once in sequence If the offer to If you do not wish to make changes do not press the DELETE is accepted then all the messages are erased button and allow the pager to return to normal operation Individual message review allows individual messages to be selected read and deleted Select USRGRPS to allow the user USRGRPS user groups to join or leave any of the groups programmed into the pager This selects the vibrator where VIBRATE fitted 18 19 To enter the open channel mode Switch the pager off Press and hold button f and then press the power button Q Release the buttons To return to normal operation momentarily press the power button Q i information Open channel is a diagnostic mode that allows the pager to display information from all transmitted calls This is a 3 digit information code followed by the identity code of the pager being called The pager will display its software title and after a short while the first 8 function digits The remainder of the function digits are displayed and the pager will enter the open channel mode To replace the clip Place your thumb on top of the clip and using a screwdriver pull the locking tab away from the pager body
13. ion Block 1 position 1 E D N F G I Language 2 S Silent R Range L Light P Switch A B C Format 0 8 0 to 8 errors L 3 4 5 6 7 8 Long Bleep Block 2 position 1 2 6 Decode algorithm 2 B Block message 3 U User groups 4 V Vibrate NOTE Where a dash appears on the display the function is disabled Language for prompts E English D Dutch N Norwegian F French G German I Italian If you select SILENT the pager will not bleep on receipt of a call The light will still flash unless it has been disabled see light below This function if selected will cause the pager to bleep and display RANGE if no valid transmission has been received for approximately 40 s Other active pager functions will be displayed alternately The RANGE facility must also be selected in the system encoder To prevent the LED from illuminating select X for this option Select this option to prevent the pager being switched off information information le Continued from previous page FORMAT is an engineering function IMPORTANT and is normally set in the factory FORMAT The format letter shown MUST 7 f said correspond to the format setting in Send a programming call for the required Individual This will save the settings the system
14. low it to operate with your paging system and to select user functions WARNING If your are not sure how to set these engineering functions please refer to your supplier If you make an invalid setting your pager might not work You must delete all identity codes from your pager before you can change the configuration 13 To delete all codes Press and hold button Ff until the top display shows the pager s current Individual Code Release the button Allow the pager to go through the user selections Wait until the display shows FRUGRHM then press and release f NEZ The display will first show PROLRHM then the individual code Press and hold O Send a DELETE ALL programming code from the system encoder The display will show NII Lies Pe ee 4 Your pager is now ready to be configured information You will need to be able to send programming calls from your paging encoder to carry out these procedures Please refer to the appropriate user guide for details IMPORTANT Please ensure that the battery is fully charged rechargeable or new disposable before programming the identity codes otherwise they might not be saved to memory Refer to the section To configurethe pager and program the identity codes for details 14 To change the format and program codes without altering the configuration Press a
15. nd release button The display will show the current format setting eg FURMAT L Whilst the format is displayed each time you press f the format will change Release the button when the required format is displayed The display will show IC Individual Code Press and hold button Ff Send a programming call for the required Individual Code from the system encoder When the new code appears release the button The pager will show the Group Codes G1 to G6 in sequence Continued on next page 15 information IMPORTANT Please ensure that the battery is fully charged rechargeable or new disposable before programming the identity codes otherwise they might not be saved to memory FORMAT is normally set in the factory from the ordering specifications The FORMAT letter shown MUST correspond to the format setting in the system encoder otherwise the pager will not work A B and C represent the three coding formats Format C is the default Blick setting A and B can be used for specific systems please refer to your supplier before using these options This will store the new format setting Continued from previous page To add a Group Code press O while it is displayed Send a programming call for the new code from the system encoder When the new code appears release the button The display will change to show the next Group Co
16. t never place a pager with a DISPOSABLE battery in a charging rack Your pager will continue to display RANGE until it receives a valid transmission Other active pager functions will be displayed alternately To review and delete stored messages The message store has a capacity of 80 characters When the store is full new messages will overwrite the existing ones starting with the oldest You can set your pager see User selectable functions page 11 to review messages using either of two options a Block message review When you initiate the message review your pager will display all the stored messages in sequence If you choose to delete then all messages are cleared from the store b Individual message review This option allows you to review and delete any stored message To view the messages press and hold until the last message is displayed Release the button The pager will display all the messages in sequence When all messages have been displayed the pager will show Me ee e Press the message button momentarily if you wish to clear all messages from the store information If you wish to pause the display press and hold The number of each message is shown on the display If you do not delete the reviewed messages the displays will show the number of stored messages Pie Display backlight When stored messag
17. the results in code 22 23 Blick Communications Limited 15 Cofton Road www blickcommunications com EXETER Devon Tel O13 England FAX 013 EX2 8QW 92 204100 92 204170 International tel 44 13 92 20 41 00 International FAX 44 13 92 20 41 70 Issue 3 Part number 010696
18. the word will be displayed alternately with other active pager functions e g RANGE LOW BATT This selection will lengthen the bleep period to 24 seconds You can still cancel the tone in the normal way by pressing the message bottom button Two bleep volume levels are available Message review method HLKMESS5X ALKMESS select individual select block Program PROGRAM If you wish to program an identity code Individual or Group press O and follow the instructions on page 5 Otherwise allow the pager to continue through the selection sequence User groups ba X9S999 ber bbbbb When you have finished your pager will return to normal operation information This screen will allow you to choose message review facility Select a tick to use BLOCK MESSAGE review or a cross to review INDIVIDUAL MESSAGES If you switch the pager off it will revert to the default setting the next time that it is switched on the default is set during pager configuration see below Programming instructions can be found on page 7 This facility allows you to join or leave any of the groups programmed into your pager Each of the programmed groups is displayed in sequence Press button f to make your choice To configure your pager These procedures allow you to set the engineering functions of your pager to al
19. urther information an information column appears on the right hand side of the instructions This gives additional information for the step that you are following or in some cases the result of your actions To prepare your pager for use Before you use your pager for the first time Please ensure that the battery is new disposable or fully charged rechargeable To ensure that a rechargeable battery is fully charged place your pager in a charging rack for 14 hours To insert or change the battery Press down on the battery door slide it towards the centre and hinge it outward to reveal the battery compartment Push down Slide In Invert the pager and allow the old battery to slide out Hinge up Place the new battery size AA into the compartment with its positive terminal facing outwards Hinge the door over the battery press down and slide it towards the side of the pager case until it clicks into position The pager will bleep and display two crosses to show that it is active If your pager shows NO CODES You will need to program it with an Identity Code before it can be used Please refer to your supplier for details information le ty ie i ee IML CONES Pager Controls All the functions of your pager are controlled by pressing combinations of the three push buttons on the side To switch your pager off Press and hold the power button QX

Download Pdf Manuals

image

Related Search

Related Contents

Genius SP-HF360A  HygroLog HL20 and HL21 version 1: User Guide  OMR装置新製品 SR-1800 発売のご案内  Height Safety Lifting Load Control Safety Management  Inspire FAQ  Metz MZ-1i User's Manual  Harbor Freight Tools 96513 User's Manual  BOMBER HID ハーレー FLTRシリーズ `99~ 専用 取扱説明書  TEFAL HB300141 Instruction Manual    