Home
Operating instructions - OPERTIS Produktkatalog
Contents
1. OPERTIS Operating instructions Framed Door System ES6610 ES7610 eLOCK GB Operating Instructions Framed Door System ES6610 ES7610 Contents TV 513 ol U e1 Lo 1 serrian aa arae aaa OBERE AR BEER EEIAERAREEEE EURE 4 PDOUU INES SINS ERUCUIOINS a 4 Explanation of the Symbols and Signal Words Used c ccccceccceeeceeeeeeeeeeeeeeeeeeees 4 Erge GLOUP ee see 4 OPERU 0 6 8 0 9 eee es ene nnn n ee ee 4 Up to date status of the INfOrmatiOn cccccccecceecceeeeeeceeeeeeeeeeeeeceeesseeeeeeeeeeeeneeeeeees 5 2 Product Description una un 5 OUT VS PO al essen eaten seated a AE 5 ETC OMAN ORIN CUD One 6 VETS GL MFON IVT O Mints eu an een dee 6 3 Mtende Se rc ssscccse tant cosedoncuarciaasccceseqecne trqed secu addaa FEERPEREFPERFEBNE 6 Area Ole LS ee een om gate anna ees 6 Condition of the product een 6 ANDERE CONGN ONS ee ee T POWER SUD DIY ausser l RES IQUAL N eK nenne ee ee ae T 4 SSAlety InStrUCHONSs creen a 7 5 Use and OMe atl On HRRPBEEHDEARBERPREREEGEDERENEFERSRERESDEERENGEEEEOREELEDESEREDEFERREBLEEEEREEEEBEERESLEREEEREEERSRRER 10 Programming fittings and identifiers 2 20222022002200000000n0 Bono anno nano nnne name nnne anne 10 Chandno the Dalee sica ri esiarliees lee 10 VUALON A Saa tee E EET E E O EEE 11 6 Servicing Cleaning and Maintenance uuusnsanunnannunnnnnunnnnnnnnnnnunnnnnunnnnnunnnnnen 12 NUS VOUS 22 2 ee T ee es u 12 leaning and malnlenance nass
2. mortise locks Part 1 Mortise locks for tubular frame doors O DIN 18250 Locks mortise locks for fire doors and smoke control doors limited The framed door system has been tested and approved for use in fire doors and smoke control doors but must also definitely be listed in the monitoring design features list of approved products of the relevant profile manufacturer OPERTIS 15 GB eLOCK Framed Door System ES6610 ES7610 Operating Instructions Dimensions All dimensions are given in mm ES6610 and ES7610 50 20 4 A Ol 18 5 252 300 51 15 5 16 OPERTIS 05 2012 eLOCK GB Operating Instructions Framed Door System ES6610 ES7610 Electro mechanical lock 3 05 2012 OPERTIS 17 GB Framed Door System ES6610 ES 610 Technical data Surface Cover caps eLOCK Operating Instructions Polyamide surface Electro mechanical lock O Latch and bolt O Forend Power supply Voltage supply Steel Stainless steel 3 volt lithium battery CR2 OPERTIS article no ES0891 Approved battery types O Energizer ICR2 O Panasonic CR 2L 1BP O VARTA CR2 Professional Battery life O Ready for use with 10 closures per day O Closures total O Standby time Specific data Operating temperature Storage temperature Air humidity for operation and storage Lock strength according to DIN 18251 Class 3 Degree of protection according to EN 60529 Memory capacity i
3. Fitting has been activated and is searching for identifiers system error Dismantle fitting contact OPERTIS Support OPERTIS 11 GB eLOCK Framed Door System ES6610 ES7610 Operating Instructions 6 Servicing Cleaning and Maintenance The servicing cleaning and maintenance may be carried out by qualified personnel only Warranty cover is excluded for damage caused by improper handling Intervals Activity Interval Cleaning and 3 months maintenance Servicing 1 year Cleaning and maintenance CAUTION Damage to property due to incorrect cleaning Incorrect cleaning can cause the surfaces to be attacked and damaged O Maintain the Framed Door system from the outside only do not remove cover caps O Do not use any alkali or acidic cleaning agents or cleaning agents containing chlorine O Do not use cleaning agents with scouring additives O Do not use scouring instruments e g brushes O Do not allow oils and greases to get inside the electro mechanical lock Proceed as follows Step Activity Figure 1 Wipe surfaces with a damp cloth 2 Lightly grease the lock latch on the slanted side 12 OPERTIS 05 2012 eLOCK Operating Instructions Servicing A 05 2012 GB Framed Door System ES6610 ES7610 CAUTION Risk of locking in or out The door cannot be opened without a fully functional fitting if the latch drops into the lock Perform functional tests with the door open Th
4. a self locking lock which automatically locks when the door is closed There is no locking in the conventional sense by means of knobs or keys mechanical locking is no longer necessary In the Framed Door system the inner lever handle is always coupled in The integrated anti panic function pulls back the latch and bolt when the inner lever handle is pressed the doors can always be opened from the inside In the Framed Door system the outer lever handle has no function in the decoupled state It can be pressed but does not have any connection with the lock latch and bolt In this state the door cannot be opened using the outer lever handle Access organisation is realised by short term coupling in of the otherwise idle disengaged outer lever handle after holding an identifier in front of the antenna If the coupled in outer handle lever is pressed the latch and bolt are pulled back There is no unlocking in the conventional sense by means of knobs or keys mechanical unlocking is no longer necessary Management and programming among other things the issue of access authorisations takes place using the eLOCK Center management software Optionally programming with eLOCK LernLosch is also possible via three programming keys without additional software Passive identifiers without their own power supply are available for authorisation at the fittings in different forms such as key fobs cards or customer specific forms Detailed inform
5. as follows Step 1 10 OPERTIS Activity Figure Undo countersunk screw on the underside of the evaluator unit cover Remove the cover of the evaluator unit Remove batteries Insert the new batteries in the battery compartment ensuring the battery polarity is correct Replace the cover and screw onto the underside Check date and time and if necessary reset see eLOCK software system documentation 05 2012 eLOCK Operating Instructions Visual signals GB Framed Door System ES6610 ES 610 The visual signals of the fitting depend on the programming The programmed fittings in the LernL sch system and the fittings programmed using eLOCK Center have a different signalling concept Note The complete visual and acoustic signals are included in the eLOCK system documentation Signalling Concept section In certain system states and events the Framed Door system emits visual signals Visual signal 2x short blue blue 2x short green green 2x short red green 2x short red red 5x long blue Repeated short red 2x short red red 4 x yellow 05 2012 Meaning Programming mode on Fitting connection by authorised identifier Fitting connection in construction site mode or permanent release mode see eLOCK system documentation Fitting Modes section No fitting connection identifier not authorised Battery flat Warning level 1 with controlled incorrect locking operations
6. ation Further information on the product is given in Section 8 Product Specifications 3 Intended Use Area of use The Framed Door system has been designed for use in narrow framed doors at internal and external doors It is not permitted to use it outdoors e g in fencing Condition of the product Framed Door systems may only be used if they are in a technically perfect condition Independent modifications and changes to the product are not allowed 6 OPERTIS 05 2012 eLOCK GB Operating Instructions Framed Door System ES6610 ES7610 Ambient conditions Use in a particularly polluted environment e g in aggressive gases high humidity in extreme temperatures or in a very dusty environment is not allowed If you have any questions please contact OPERTIS Support Power supply All battery operated fittings activate acoustic and or optical battery flat warnings and controlled failed locking if the battery output in the fitting is fading The battery should then be replaced without delay Residual risk lf used properly and if the maintenance instructions are followed this product will support your property security However the following residual risks cannot be excluded O In the event of failure of the electronics there is a risk of locking out In this case the door can only be opened from the outside with mechanical aids In this case please contact OPERTIS Support O lf the battery flat warning is repeat
7. cessfully completed suitable vocational training for these activities or has had the necessary appropriate experience OPERTIS Support If you have any questions extending beyond the information provided in these instructions please contact OPERTIS GmbH Prof Bier Stra e 1 5 D 34454 Bad Arolsen Tel 49 5691 87741 200 Fax 49 5691 87741 281 E Mail support opertis de 4 OPERTIS 05 2012 eLOCK GB Operating Instructions Framed Door System ES6610 ES7610 Up to date status of the information All details on the product images dimensions and models correspond to the status at the time the product is delivered We reserve the right to make changes due to technical progress and the resulting continuous improvement process to which our products are subjected The current version of these instructions and further information is also available on our internet site www opertis de Dated 05 2012 2 Product Description Component parts The following drawing shows the main component parts of the Framed Door system Read out unit Evaluator unit Electro mechanical lock Control latch Latch Dead bolt O o FR W NhN 05 2012 OPERTIS 5 GB eLOCK Framed Door System ES6610 ES7610 Operating Instructions Functional principle The OPERTIS eLOCK lock system ensures continuous public and commercial building fitout Special fitting solutions are available for different door types The Framed Door system includes
8. e Otherwise the electronic lock of the framed door system cannot uncouple and lock the door if the lever handle is kept pressed for longer than 2 min after the opening time default 20 sec The framed door system then automatically tries to uncouple the outer lever handle at defined intervals CAUTION Unauthorised access The inner lever handle of the Framed Door system is coupled as an anti panic lock This enables the door to be opened at any time using the inner lever handle You should note this above all when using the fitting in publicly accessible doors and doors through which the inner lever handle can be easily accessed from the outside CAUTION Unauthorised access When delivered the Framed Door systems are in construction site mode Access is possible with any OPERTIS identifier even if they are not programmed Program the authorisations immediately after installation to prevent unauthorised access see eLOCK system documentation software Check time and if necessary reset OPERTIS 9 GB eLOCK Framed Door System ES6610 ES7610 Operating Instructions 5 Use and Operation Programming fittings and identifiers Fittings and identifiers are programmed using the eLOCK Center management centre or the eLOCK LernLosch system Detailed information on this is given in the eLOCK system documentation software Changing the batteries Note Note the battery type information in Section Technical data Proceed
9. e 12 SEITE ING Er een ee een eg aerate a ae ete ee eect 13 7 Problems ANG Solulions s essen eerheeeeehehe 14 8 Produei Specitieations u a e ea ein 15 Declaration of ConlormiiYaniann ana E E E Ea 15 DIMONSION S eres EE S S 16 Fecnnicakdald asaur e eeertree mee eter are 18 9 DISPOSal cszesesecpeetecescvecereccrmccewttrecsace ce recaceda aca cicasececsdecesneedadsabmsaveanecdavecnsecavecn eeebancheky 19 POO es ee ee ee ee ee ee 19 BAOG S Ares ee ee ade 19 05 2012 OPERTIS 3 GB eLOCK Framed Door System ES6610 ES7610 Operating Instructions 1 Introduction About these instructions These instructions contain important notes and information on operation of the ES6610and ES7610 Framed Door systems O Read through the instructions carefully and attentively O Keep the instructions in a safe place and pass them on to each subsequent user of the Framed Door systems Explanation of the Symbols and Signal Words Used WARNING Indicates risks which could result in fatal or severe personal injuries CAUTION Indicates risks which could result in fatal or severe personal injuries Indicates risks which could result in damage to CAUTION property Note Denotes information notes and tips on optimum use of the instructions and the product Target group These instructions are directed at competent personnel entrusted with the servicing maintenance and disposal of trouble free operation of the Framed Door system and who has suc
10. e and tries to uncouple the mechanically prevented outer lever handle again the uncoupling at defined intervals 14 OPERTIS 05 2012 eLOCK GB Operating Instructions Framed Door System ES6610 ES7610 Problem Possible cause Solution Each identifier Fitting is not Program fitting see couples in the outer programmed eLOCK system lever handle construction site documentation mode software Latch does not latch Latch recess in the Adjust the latch recess into position locking plate does not in the locking plate to match the latch position the latch position of the of the electro electro mechanical lock mechanical lock The lock does not The self locking is Immediately replace lock defective lock The dead bolt is not The panic function is Immediately replace drawn in by pressing defective lock the inner lever handle The door may no or the coupled outer longer be closed as lever handle the panic function is no longer available 8 Product Specifications Declaration of conformity 05 2012 OPERTIS GmbH herewith declares that the Framed Door system fulfils the basic standards and other relevant specifications of the 1999 5 EG and 2002 95 EG directives and that they are CE compliant A copy of the statement of conformity can be ordered from the OPERTIS Support Installation in mortise locks prepared for profile cylinders in accordance with the following standards O DIN 18251 2 Locks
11. e following functional tests must be performed once a year Step Activity 1 Check for secure fit ofthe lock the installed fittings and the screws 2 Press the outer lever handle 3 Hold authorised OPERTIS identifier in front of the read out unit then press the outer door lever Press inner lever handle 5 Check self locking Press in latch and control latch then keep the control latch pressed and let go of the latch 6 Check the panic function Press the inner lever handle with the lock locked 7 Check the panic function Press the coupled outer lever handle with the lock locked 8 CAUTION Risk of being locked out When the door is closed from the outside an authorised identifier must be available to enable the door to then be re opened Close the door from the inside Result All components of the Framed Door system are securely installed The control latch the latch and the dead bolt move smoothly and easily The outer lever handle is idle disengaged The latch is not drawn in The latch is drawn in and automatically returns to the starting position after pulling back The dead lock must spring out The latch and the bolt can no longer be pushed in The dead bolt and latch are drawn in by the action The dead lock must spring out OPERTIS 13 GB eLOCK Framed Door System ES6610 ES7610 Operating Instructions Step Activity Result 9 Press the inner le
12. edly ignored the Framed Door system stops all activities Active Power Off The door cannot be opened from the outside This state is retained in until the battery has been replaced and then an external power supply has been provided O In Active Power Off i e if the battery is completely flat or missing the Framed Door system stops all activities The door can then only be opened from the outside with the external power supply EPS ES6781 for ES5000 plus systems or the ES7781 for eLOCK and eLOCK LernLosch systems 4 Safety Instructions The following safety instructions must be read and followed before use OPERTIS does not accept any liability whatsoever for personal losses or injuries or damage to property caused by failure to note and follow these instructions WARNING Risk of personal injuries The Framed Door system has been tested and approved for use in framed fire doors and framed smoke control doors If used in a fire door or smoke control door it must also be listed in the monitoring design features list of approved products of the relevant profile manufacturer 05 2012 OPERTIS 7 GB eLOCK Framed Door System ES6610 ES7610 Operating Instructions WARNING Risk of personal injuries An approved framed door version with anti panic function must be installed in the escape direction for doors in escape routes WARNING Risk of personal injuries lf the Framed Door system is used in doors in escape rout
13. es an approved lock model lever handle side with panic function in the direction of escape must be installed Otherwise the door does not have the anti panic function WARNING Danger of personal injury from the battery Any improper contact with the battery can lead to damage to the health The following instructions must be noted Only use batteries supplied or approved by OPERTIS Do not open solder or weld the batteries Do not throw the batteries into fire Do not recharge the batteries Remove empty batteries immediately from the fitting Store batteries out of the reach of children Do not touch leaking batteries without appropriate protection Avoid contact with the eyes or mouth CAUTION Danger of material damage O0O00000 Malfunctions can occur if unapproved battery types are used The fitting does not signal any battery warnings and does not switch to the secured end state Active Power Off Only use battery types approved by OPERTIS CAUTION Risk of locking in or out The door cannot be opened without a fully functional fitting if the latch drops into the lock Leave the door open during installation and while changing the battery or ensure that the door can be opened at any time without using the fitting 8 OPERTIS 05 2012 eLOCK GB Operating Instructions Framed Door System ES6610 ES7610 05 2012 CAUTION Unauthorised access After opening the door let go of the outer lever handl
14. n the fitting Identifiers Protection zones membership of a group of fittings Events memory authorisation attempts 18 OPERTIS depending on use conditions and fitting type O 3t04 years O 25 000 closures O up to 6 years Read out unit 20 C to 55 C Evaluator unit 0 C to 45 C 20 tot 5 max 95 non condensing Increased break in resistance and increased user frequency IP43 ES6xxx ES7Xxx ES7XXX AddDelete 60 000 80 000 100 296 30 512 628 05 2012 eLOCK GB Operating Instructions Framed Door System ES6610 ES7610 9 Disposal Product X Disposal in accordance with WEEE Directive 2002 96 EC O Do not dispose of product by throwing it in the local household waste O Return product to OPERTIS or dispose of at a municipal collection point for hazardous electrical wastes Batteries X O Do not dispose of batteries in the local household waste but instead hand them in to public battery collection points O Do not throw batteries into a fire O Do not store used batteries together O Dispose of batteries only if they are discharged 05 2012 OPERTIS 19 OPERTIS GmbH Prof Bier Stra e 1 5 O P RT S D 34454 Bad Arolsen Telefon 49 5691 87741 0 Telefax 49 5691 87741 310 info opertis de www opertis de M7000 65GBB V004 05 2012
15. ver handle or The bolt and latch are pulled coupled outer lever handle back the bolt must not scrape on the locking plate 10 Read fitting information see eLOCK system documentation software 7 Problems and Solutions Problem Possible cause Solution Framed Door system ldentifier is not a Use OPERTIS does not respond OPERTIS identifier identifier Identifier is not Program identifier see programmed or does eLOCK system not have the necessary documentation authorisations software Identifier is defective Replace identifier Reset time see eLOCK or wrong time system documentation software Change the batteries defective Replace the Framed jammed Door system Lever handle fitting has Correctly install lever Lever handle is not horizontal been installed slanted handle fitting and check or under pressure for smooth and easy movement Lever handles are too __ Replace the existing heavy lever handles with lighter ones or use additional retention spring Framed Door system Switch mode of the Deactivate switch is continuously fitting is activated see mode coupled The door eLOCK system O Reconfigure the can be opened documentation Fitting fitting time profile without the Modes section Authorisation witk authorisation of an Switch IT to Identifier deactivate switch mode The outer lever handle The framed door was held too long after system automatically the opening tim
Download Pdf Manuals
Related Search
Related Contents
Samsung SP-M221 Bruksanvisning Viewsonic A Series VA2012wb user manual Descargar el manual de usuario ひかり電話対応VoIPアダプタ N906iL収容 設定マニュアル Instantáneos Lexar 16GB JumpDrive S50 Avaya IP Office Softphone - Northwest Communications Inc. User`s Manual Samsung L768 古銅 User Manual Copyright © All rights reserved.