Fitting and Operating Instructions GB
Contents
1. Spare parts Colour frame Nr Spare parts beige white grey 1a Replacement dome model 28 290 52VB 290 52VAW 290 52VG 1b Replacement dome model 32 320 52VB ween NG Replacement dome model 40 150 cm air flow 420 52VB 420 52VAW 420 52VG 2a Outer frame model 28 280 22B 280 22AW 280 22G 2b Outer frame model 32 320 22B 2c Outer frame model 40 401 400 21B 400 21AW 400 21G Outer frame model 403 400 23B 3a Inner frame model 28 280 21B 280 21AW 280 21G 3b Inner frame model 32 320 21B wee 3c Inner frame model 40 400 22B 400 22AW 400 22G Inner frame model 401 403 401 22B 4 Handle for replacement roller 450 3B_ _ 5 Locks 1 set supplied in polybag with hanger single packed For rooflight model 28 270 99S 270 99S 270 99S For rooflight models 32 40 403 420 99S 420 99S 420 99S 6 Screws for handles 8000 4 8000 4 8000 4
2. A a Wi ii ay ISO 9001 2008 IMID K ISO 14001 2004 Cert No 01 100 89747 Cert No 01 104 069609 Ma und Pr zision in Kunststoff Metall und Plastikverarbeitungs GmbH amp Co KG Kierspe Internet www mpk kierspe de Fitting and Operating Instructions Rooflight Model 28 32 40 lt 1 a J Issue Nov 2013 We reserve the right to change technical specifications without notice E amp OE Illustration tf f jj MMMM HHN MU HEERE We only recommend installation by authorised dealers Please read these instructions carefully before fitting and operating the rooflights Important We cannot be held responsible for incorrect fitting handling or operation Any product faults relating to the production and materials used should be notified to us via an authorised dealer immediately Warning Fitting position Aperture size Roof thickness Fitting direction Fitting screws Sealing Fitting Fitting Instructions Never stand on the dome of the rooflight See picture 1 Choose a fitting position that will not interfere with other roof mounted components e g roof racks antenna s etc and avoid internally installed electrical cables and furniture which could impede the correct operation of the rooflight The rooflight should only be fitted to a flat roof surface both in ternally and externally Depending on rooflight model see technical data page 6 7 Ensure the correct roo
3. flight is selected for the roof thickness for available size options see page 6 Rooflights must only be fitted with the operating handles facing the front and rear of the vehicle not across the vehicle The length of the screw should be determined by the roof thick ness plus approximately 10 mm tor the screw to enter the upper frame Secure only with pan or round headed screws not supplied 3 5 mm head according to DIN ISO 7049 DIN 7981 Do not use countersunk screws as they will damage the rooflight frame See picture 4 Use only long term flexible sealant suitable for external use not supplied and also suitable for the material of the upper frame Consult your sealant supplier Before fitting the rooflignt remove the profiles covering the flynet and blind rollers These are temporarily partially fitted into place when new PLEASE NOTE When fully fitted these profiles cannot be removed without being damaged It is therefore important to make sure the rooflight is fitted and operates correctly before fully installing the profiles Correctly align the upper and lower frames and secure evenly with the screws Do not over tighten as this may damage the frame or affect the correct operation of the rooflight If the inner frame starts to distort the correct torque has been reached See picture 2 3 Screws not supplied Operation Instruction Instruction for use The rooflight can be opened fully or in four differe
4. nt directions so that the dome can be angled against driving weather conditions To open squeeze the locks optional into the handles and push open To open and close pull the flynet slightly into inner direction until it slides beside the flynet click Do not open more than 90 to avoid damaging the hinges Do not over bend as this may break the flynet frame Free air flow A When closed there is a free airflow through the rooflight which must be kept free at all times see technical data page 6 7 Never close the openings of the free air flow Before driving IMPORTANT All rooflights must be closed and locked down before travelling See picture 5 6 Care Instructions Cleaning The rooflight should only be washed by hand using a sponge with plenty of clean water to avoid scratching Caustic detergents and solvents may attack the plastic and make it brittle or disintegrate For easier cleaning of the dome it can be removed from the frame by releasing the four screws holding the handle arms Models from May 2010 Trox TK10 screws See picture 7 Make sure that only the original screws are used when replacing AN the dome and that they enter the thread in the plastic correctly Do not over tighten Never remove the screws holding the dome and the handles to AN gether See picture 8 These are secured by a torque screwdriver and should only be handled by an approved dealer Remove the flynet The flynet is hanged in and it i
5. s removed by first opening fully and hanging out from the frame Reverse the process to install Attention To avoid damage do not bend the flynet frame Clean the flynet mesh only with clean water too Technical Information Product description Opaque rooflight with free airflow Spring assisted mechanism flipable into four different directions with locks Concealed fixing screws Removable flynet optional roller blind ECE R43 Whole Vehicle Type Approved Please ask for further details Technical Data Dome outer frame material Polypropylene Model 28 Aperture 280 x 280 mm Size dome 330 x 330 mm Free air flow 60 cm Height over roof 78mm Model 32 Aperture 320 x 360 mm Size dome 380 x 420 mm Free air flow 120 cm Height over roof 83 mm Model 40 Aperture 400 x 400 mm Size dome 480 x 480 mm Free air flow 30 cm 150 cm Height over roof 91 mm Technical Information Model Options Model 28 Not available anymore has been replaced by rooflight model 29 Model 32 white grey beige roller net roof thickness air flow weight 320VB 24 46 mm 120 cm 1350 g 320VNB X 24 46 mm 120 cm 1400 g Model 40 white grey beige roller net roof thickness air flow weight 400VAW 400VB 24 46 mm 150 cm 1700 g 400VNAW 400VNB 24 46 mm 150 cm 1750 g 401VB 32 55 mm 150 cm 1780 g 401VNB 32 55 mm 150 cm 1830 g 403VB 56 89 mm 150 cm 1850 g 403VNB 56 89 mm 150 cm 1900 g
Download Pdf Manuals
Related Search
Related Contents
UM0621 User manual A4 1枚パンフレット Propuestas de accesorios - Putzmeister Mörtelmaschinen Scosche HA1573B mounting kit Pioneer DVD-103S Blu-ray Player User Manual Manuel Mil Office, partie pers Eurofase 23205-055 Installation Guide 特記仕様書 Pdf User manual for Fast Power Modified Sine Philips HX6001 Copyright © All rights reserved.