1. l i _ 2 aus the instrument components might get hot during operation Items in curved brackets are optional extras for additional price Caution Specifications Pressure ranges Type of pressure Oxygen version of model F 20 bar As of 0 25 Gauge pressure Materials m Wetted parts Internal transmission fluid Stainless steel or Elgiloy Halocarbon oil Not for model with pressure ranges gt 25 bar 300 psi Permissible temperature of E Medium When designing your plant take into account that the stated values e g burst pressure over pressure safety apply depending on the material thread and sealing element used 12 WIKA Operating instructions Betriebsanleitung F 20 F 21 20 60 C 4 140 F WIKA Operating instructions Betriebsanleitung F 20 F 21 2103870 06 GB D 04 2010 2103870 06 GB D 04 2010 8 Adjustment of zero point span Adjustment of zero point span We do not recommend to adjust the span potentiometer It is used for adjustment ex factory and should not be adjusted by you unless you have adequate calibration equip ment at your disposal at least three times more accurate than the instrument being tested m Make sure wires are not cut or pinche during disassembly and reassembly of the connectorOpen the pressure trans mitter by twisting off the field case over E Adjust the zero point Z by generating the lower limit
2. 20 mA 3 wire RA lt U 3V 0 02A 0 5 V 3 wire RA gt 5000 0 10 V 3 wire RA gt 10000 F 20 F 21 2103870 06 GB D 04 2010 2103870 06 GB D 04 2010 Specifications Test circuit signal maximum ohmic load RA Adjustability zero span Model F 20 F 21 Other signal output on request Only for instruments with 4 20 mA signal output RA lt 5 Ohm with 20 mA 5 using potentiometers inside the instrument Response time 10 90 ms lt 1 Insulation voltage DC V 500 Accuracy of span 0 5 0 25 4 Including non linearity hysteresis zero point and full scale error corresponds to error of measurement per IEC 61298 2 Adjusted in vertical mounting position with lower pressure connection gt Accuracy for pressure ranges 2 0 25 bar 100 INWC Non linearity of span lt 0 2 BFSL according to IEC 61298 2 Non repeatability of span lt 0 1 according to IEC 61298 2 1 year stability of span lt 0 2 at reference conditions Permissible temperature of E Medium m Ambience E Storage Compensated temp range Temperature coefficients within compensated temp range m Mean TC of zero m Mean TC of range 30 100 C 40 125 C 9 20 0 C0 105 1 40 100 C 22 212 F 40 257 F 9 4 176 F 22 221 F 40 212 F 6 Response time for model F 20 lt 10 ms at medium temperatures below lt 30 C 22 F for
3. Co KG Phone 48 54 230 11 00 Phone 43 1 8 69 16 31 E Mail info manometry com pl E Mail info wika at Russia ZAO WIKA MERA Benelux WIKA Benelux Phone 7 495 648 01 80 Netherlands Phone 31 4 75 53 55 00 E Mail info wika ru E Mail info wika nl Singapore WIKA Instrumentation Pte Ltd Brazil WIKA do Brasil Ind e Com Ltda Phone 65 68 44 55 06 Phone 55 15 32 66 16 55 info wika com sg E Mail marketing wika com br South Africa WIKA Instruments Pty Ltd Canada WIKA Instruments Ltd Phone 27 11 6 21 00 00 Phone 1 780 463 7035 E Mail sales wika co za E Mail info wika ca Spain Instrumentos WIKA S A China WIKA International Trading Phone 34 902 902 577 Shanghai Co Ltd E Mail info wika es Phone 86 21 53 85 25 73 Switzerland MANOMETER AG E Mail wikash online sh cn Phone 41 41 9 19 72 72 France WIKA Instruments s a r l E Mail info manometer ch a ae 84 84 Taiwan WIKA Instrumentation Taiwan Ltd SMT MO NSE Phone 886 34 20 60 52 Germany WIKA Alexander Wiegand SE amp Co KG E Mail info wika com tw ae ad ig 20 Ukraine WIKA Pribor GmbH u eae eee Phone 38 062 345 34 16 India WIKA Instruments India Pvt Ltd E mail info wika donetsk ua a 91 ae 05 2001 United Arab WIKA Middle East FZE mal SA ES RIN Emirates Phone 971 4 883 90 90 Italy WIKA Italiana SRL E Mail wikame emirates net ae on United Kingdom WIKA Instruments Ltd a Phone 44 1737 644 008 Japan WIKA JAPAN K K E Mail in
4. E Konfektionieren Sie die abgemantelten Aderenden mit Aderendh lsen z E Schrauben Sie den Geh usedeckel auf SOENS piel m L sen Sie mit einem Maulschl ssel SW24 die Kabelverschraubung m Elektrischer Anschluss Mit innenliegenden Federklemmen Anschlussquerschnitt m F hren Sie das Kabel durch die Kabelverschraubung in den ge ffneten Geh usekopf max 2 5 mm Erdungsklemme innen bei Verschraubung m Dr cken Sie den entsprechenden Kunststoffhebel am Federklemmblock mit einem Messing vernickelt und CrNi und CrNi Conduit Schraubendreher herunter damit sich der Klemmkontakt ffnet Interne bertragungsfl ssigkeit Synthetisches l m F hren Sie das konfektionierte Kabelende in die ffnung ein und lassen den Kunststoff 3 Nicht vorhanden bei Typ F 20 f r Messbereiche gt 25 bar hebel los so dass das Kabelende im Federklemmblock eingeklemmt wird m Hilfsenergie UB DC V 10 30 14 30 bei Ausgang 0 10 V m Nach Anschlie en der einzelnen Adern ziehen Sie die Kabelverschraubung fest und ver 11 30 bei Ausgang 4 20 mA schrauben den Gehausedeckel Ausgangssignal und zulassige RA in Ohm Funktion des Testkreises fur 2 Leiter Max ohmsche B rde RA 4 20 mA 2 Leiter RAS U 10 V 0 02 A Anhand des Testkreises ist es m glich w hrend des normalen Betriebes eine Strommessung 0 20 mA 3 Leiter RA lt U 3 V 0 02 A durchzuf hren ohne das Ger t abzuklemmen Sie m ssen hierzu ein Amperemeter Innen Fe
5. Pressure connection with internal diaphragm standard version F 21 Pressure connection with flush diaphragm for highly viscous or solids entrained media which might clog the pressure port Function The pressure prevailing within the application is transformed into a standardised electrical signal through the deflection of the diaphragm which acts on the sensor element with the power supply fed to the transmitter This electric signal changes in proportion to the pressure and can be evaluated correspondingly 4 WIKA Operating instructions Betriebsanleitung F 20 F 21 2103870 06 GB D 04 2010 2103870 06 GB D 04 2010 GB 5 For your safety 5 For your safety E Select the appropriate pressure transmitter with regard to scale range performance and specific measurement conditions prior to installing and starting the instrument E Observe the relevant national regulations e g EN 50178 and observe the applicable standards and directives for special applications e g with dangerous media such as acetylene flammable gases or liquids and toxic gases or liquids and with refrigeration plants or compressors If you do not observe the appropriate regulations serious injuries and or damage can occur E Open pressure connections only after the system is without pressure m Please make sure that the pressure transmitter is only used within the overload threshold limit all the time E Observe the ambient and working conditions o
6. cksendeformular vorliegt Eine solche Erkl rung beinhaltet alle Materialien welche mit dem Ger t in Ber hrung kamen auch solche die zu Testzwecken zum Betrieb oder zur Reinigung eingesetzt wurden Das R cksendeformular ist ber unsere Internet Adresse www wika de www wika com verf gbar 11 Lagerung Entsorgung Ergreifen Sie bei Lagerung und Entsorgung Vorsichtsma nahmen f r Mess stoffreste in ausgebauten Druckmessger ten Wir empfehlen eine geeignete Warnung und sorgf ltige Reinigung Messstoffreste k nnen zur Gef hrdung von Menschen Umwelt und Einrichtung f hren Lagerung Montieren Sie die Schutzkappe bei Lagerung des Druckmessger tes damit die Membran nicht besch digt wird F 21 Entsorgung Entsorgen Sie Ger tekomponenten und Verpackungsmaterialien entsprechend den einschl gigen landesspezifischen Abfallbehandlungs und Entsorgungsvorschriften des Anliefergebietes Technische nderungen vorbehalten F 20 F 21 WIKA Operating instructions Betriebsanleitung WIKA Global Argentina WIKA Argentina S A Korea WIKA Korea Ltd Phone 54 11 47 30 18 00 Phone 82 2 8 69 05 05 E Mail info wika com ar E Mail info wika co kr Australia WIKA Australia Pty Ltd Malaysia WIKA Instrumentation M Sdn Bhd Phone 61 2 88 45 52 22 Phone 60 3 56 36 88 58 E Mail sales wika com au E Mail info wika com my Austria WIKA Messger tevertrieb Poland WIKA Polska S A Ursula Wiegand GmbH amp
7. 0 5 V 3 Leiter RA gt 5000 widerstand lt 15 Ohm an die Klemmen Test anschlie en S S 0 10 V 3 Leiter RA gt 10000 N N 7 Inbetriebnahme Betrieb 7 Inbetriebnahme Betrieb Technische Daten Typ F 20 F 21 Andere Ausgangssignale auf Anfrage Testkreissignal max ohmsche B rde RA Einstellbarkeit Nullpunkt Spanne Nur bei Typen mit 4 20 mA Ausgangssignal RA lt 5 Ohm mit 20 mA 5 durch Potentiometer im Ger t Einstellzeit 10 90 ms lt 1 Isolationsspannung DC V 500 Genauigkeit d Spanne lt 0 5 0 25 Nichtlinearit t Nichtwiederholbarkeit Stabilit t pro Jahr 4 Einschlie lich Nichtlinearit t Hysterese Nullpunkt und Endwertabweichung entspricht Messabweichung nach IEC 61298 2 Kalibriert bei senkrechter Einbaulage Druckanschluss nach unten 5 Genauigkeit f r Messbereiche 2 0 25 bar d Spanne d Spanne d Spanne lt 0 2 BFSL nach IEC 61298 2 lt 0 1 nach IEC 61298 2 lt 0 2 bei Referenzbedingungen Zul ssige Temperaturbereiche m Messstoff m Umgebung E Lagerung Nenntemperaturbereich Temperaturkoeffizienten im Nenntemperaturbereich m Mittlerer TK des Nullpunktes m Mittlerer TK der Spanne C C C 30 100 40 125 9 20 80 30 105 40 100 Einstellzeit bei Typ F 20 lt 10 ms bei Messstofftemperatur lt 30 C f r Messbereiche bis 25 bar Einstellzeit bei Typ F 21 lt 1
8. of the pressure range E Adjust the span S by generating the higher limit of the pressure range m Check the zero point E f the zero point is incorrect repeat procedure as required m Reassemble the instrument carefully m Make sure all sealings and o rings are not damaged and correctly installed to assure the rated moisture ingress protec tion Recommended recalibration cycle 1 year L G For further information 49 9372 132 295 14 WIKA Operating instructions Betriebsanleitung F 20 F 21 2103870 06 GB D 04 2010 2103870 06 GB D 04 2010 9 Maintenance accessories 10 Trouble shooting 9 Maintenance accessories E WIKA pressure transmitters require no maintenance m Have repairs performed by the manufacturer only Accessories For details about the accessories e g connectors please refer to WIKA s price list WIKA s product catalog on CD or or contact our sales department 10 Trouble shooting Open pressure connections only after the system is without pressure Warning E Take precautions with regard to remaining media in removed pressure trans mitters Remaining media in the pressure port may be hazardous or toxic m Remove the pressure transmitter from service and mark it to prevent it from being used again accidentally if it becomes damaged or unsafe for opera tion E Have repairs performed by the manufacturer only Do not insert any pointed or hard objects into th
9. 0 ms bei Messstoff temperatur lt 30 C C d Spanne d Spanne 0 80 lt 0 2 10 K lt 0 4 f r Messbereiche lt 250 mbar s 02 10 K CE Kennzeichen m Druckger terichtlinie 26 WIKA Operating instructions Betriebsanleitung Bei diesem Ger t handelt es sich um ein druckhaltendes Ausr stungsteil im Sinne der Richtlinie 97 23 EG F 20 F 21 2103870 06 GB D 04 2010 2103870 06 GB D 04 2010 Technische Daten Typ F 20 F 21 m EMV Richtlinie 2004 108 EG EN 61326 Emission Gruppe 1 Klasse B und St rfestigkeit industrieller Bereich Schockbelastbarkeit Vibrationsbelastbarkeit 600 nach IEC 60068 2 27 Schock mechanisch 10 nach IEC 60068 2 6 Vibration bei Resonanz Elektrische Schutzarten m Kurzschlussfestigkeit S gegen U m Verpolschutz U gegen U Gewicht kg Ca 0 35 _ ee ee ee Ss Angaben in geschweiften Klammern beschreiben gegen Mehrpreis lieferbare Sonderheiten Technische Daten Messbereich Druckart Werkstoff m Messstoffber hrte Teile Interne bertragungsfl ssigkeit Zul ssige Temperaturbereiche m Messstoff Sauerstoffausf hrung Typ F 20 bar Ab 0 0 25 Uberdruck CrNi Stahl oder Elgiloy Halocarbon oil 1 Nicht vorhanden f r Messbereiche gt 25 bar 20 60 Beachten Sie bei der Auslegung Ihrer Anlage dass die angegebenen Werte z B Berstdruck berlastgrenze in Abh ngigkeit vom verwende
10. Current terms and conditions apply Details are available on Es gelten unsere aktuellen Verkaufs und Lieferbedingungen siehe unter www wika de 2103870 06 GB D 04 2010 WIKA Alexander Wiegand SE amp Co KG Alexander Wiegand Stra e 30 63911 Klingenberg Germany Tel 49 93 72 132 295 Fax 49 93 72 132 706 E Mail support tronic wika de www wika de F 20 F 21 Operating instructions Betriebsanleitung Pressure transmitter C Druckmessumformer F 20 WIKA Part of your business Contents Inhalt Contents Page 3 17 ejz oo ee ee ee ee ee EEE 9 10 Trouble shooting 11 Storage disposal Important details for your information A quick overview for you Signs symbols and abbreviations Function For your safety Packaging Starting operation Adjustment of zero point span Maintenance accessories Inhalt Seite 18 31 D 1 Wichtiges zu Ihrer Information 2 Der schnelle berblick f r Sie 3 Zeichenerkl rungen Abk rzungen 4 Funktion 5 Zu Ihrer Sicherheit 6 Verpackung 7 Inbetriebnahme Betrieb 8 Einstellung Nullpunkt Spanne 9 Wartung Zubeh r 10 St rbeseitigung 11 Lagerung Entsorgung 2 WIKA Operating instructions Betriebsanleitung F 20 F 21 2103870 06 GB D 04 2010 2103870 06 GB D 04 2010 1 Important details for your information 2 A quick overview for you 1 Important details for your information Read these operatin
11. all and start the pressure transmitter only if you are familiar with the relevant regulations and directives of your country and if you have the qualification required You have to be acquainted with the rules and regulations on measurement and control technology and elec tric circuits Depending on the operating conditions of your application you have to have the corresponding knowledge e g of aggressive media 2 A quick overview for you If you want to get a quick overview read Chapters 3 5 7 and 11 There you will get some short safety instructions and important information on your product and its starting Read these chapters in any case WIKA Operating instructions Betriebsanleitung F 20 F 21 3 Signs symbols and abbreviations 4 Function 3 Abbreviations signs and symbols Potential danger of life or of severe injuries The product complies with the applicable European Potential danger of life or Notice important informa hd of severe injuries due to tion malfunction Warning catapulting parts Potential danger of burns AN due to hot surfaces Caution 2 wire Two connection lines are intended for the voltage supply The supply current is the measurement signal 3 wire Two connection lines are intended for the voltage supply One connection line is intended for the measurement signal U Positive supply connection U Negative supply connection S Positive measurement connection 4 Function F 20
12. aus Das richtige Drehmo ment ist abh ngig von der Dimension des Druckanschlusses sowie der verwendeten Dichtung Form Werkstoff Verwenden Sie zum Ein bzw Ausschrauben nicht das Geh use als Angriffsfl che E Beachten Sie beim Einschrauben dass die Gewindeg nge nicht verkantet werden E Angaben zu Einschraubl chern und Einschwei stutzen entnehmen Sie bitte unserer Technischen Information IN 00 14 unter www wika de 22 WIKA Operating instructions Betriebsanleitung F 20 F 21 2103870 06 GB D 04 2010 2103870 06 GB D 04 2010 7 Inbetriebnahme Betrieb B Montage elektrischer Anschluss E Erden Sie das Ger t ber den Druckanschluss und oder die Anschlussklemme 5 E Betreiben Sie den Druckmessumformer mit geschirmter Leitung und erden Sie den Schirm auf mindestens einer Leitungsseite wenn die Leitungen l nger als 30m 2 Leiter bzw 3m 3 bzw 4 Leiter sind oder das Geb ude verlassen E Schutzart IP nach IEC 60 529 Die angegebenen Schutzarten gelten nur im gesteckten Zustand mit Leitungsteckern Buchsen entsprechender Schutzart E Wahlen Sie den Kabeldurchmesser passend zur Kabeldurchf hrung des Steckers Achten Sie darauf dass die Kabelverschraubung des montierten Steckers korrekt sitzt und dass die Dichtungen vorhanden und nicht besch digt sind Ziehen Sie die Verschraubung fest und berpr fen Sie den korrekten Sitz der Dichtungen um die Schutzart zu gew hrleisten E Stellen Sie bei Kabelausg ngen s
13. den Nullpunkt E Wenn der Nullpunkt nicht stimmt ggf Prozedur wiederholen E Schlie en Sie das Druckmessgerat Z Nullpunkt 28 WIKA Operating instructions Betriebsanleitung F 20 F 21 2103870 06 GB D 04 2010 06 GB D 04 2010 2103870 8 Einstellung Nullpunkt Spanne 9 Wartung Zubeh r 10 St rbeseitigung wieder sorgf ltig Achten Sie darauf dass die Dichtungen unbesch digt und sauber sind und auf die korrekte Lage der Dichtungen um die Schutzart zu gew hrleisten 9 Wartung Zubeh r E WIKA Druckmessger te sind wartungsfrei m Lassen Sie Reparaturen nur vom Hersteller durchf hren Zubeh r Entnehmen Sie bitte Zubeh rangaben z B Stecker unserer aktuellen Standardpreisliste dem CD Katalog oder setzen Sie sich mit unserem Vertriebsmitarbeiter in Verbindung 10 St rbeseitigung ffnen Sie Anschl sse nur im drucklosen Zustand Warnung E Ergreifen Sie Vorsichtsma nahmen f r Messstoffreste in ausgebauten Druckmessger ten Messstoffreste k nnen zur Gef hrdung von Menschen Umwelt und Einrichtung f hren E Setzen Sie das Druckmessger t au er Betrieb und sch tzen Sie es gegen versehentliche Inbetriebnahme wenn Sie St rungen nicht beseitigen k nnen m Lassen Sie Reparaturen nur vom Hersteller durchf hren Warnung Verwenden Sie keine spitzen bzw harten Gegenst nde zur Reinigung denn die Membran des Druckanschlusses darf nicht besch digt werden WIKA Operating
14. e pressure port for cleaning to prevent damage to the diaphragm of the pressure connection Warning WIKA Operating instructions Betriebsanleitung F 20 F 21 10 Trouble shooting GB Please verify in advance if pressure is being applied valves ball valve etc open and if the right voltage supply and the right type of wiring 2 wire 3 wire has been chosen Failure No output signal No False output signal Possible cause No incorrect voltage supply or current spike Cable break Incorrectly wired e g Connected as 2 wire instead of 3 wire system Output signal unchanged after change Mechanical overload through over in pressure Abnormal output signal Signal span dropping off too small Signal span erratic Abnormal zero point signal pressure Wrong supply voltage or current spike Span incorrectly adjusted Diaphragm is damaged e g through impact abrasive agressive media corrosion of diaphragm pressure connector transmission fluid missing Seal Sealing face damaged conta minated seal mounted incorrectly threads crossed Moisture present e g at the cable tail Power supply too high too low Mechanical overload through over pressure Electromagnetic interference source in the vicinity e g inverter drive Diaphragm is damaged e g through impact abrasive agressive media corrosion of diaphragm pressure connector Zero point signal unstable too low high Moisture
15. erte Druckmessger te E Bei frontb ndiger Ausf hrung F 21 mit vormontierten Dichtungen und Schutzkappe E Untersuchen Sie das Druckmessger t auf eventuell entstandene Transportsch den Sind offensichtlich Sch den vorhanden teilen Sie dies dem Transportunternehmen und WIKA unverz glich mit E Bewahren Sie die Verpackung auf denn diese bietet bei einem Transport einen opti malen Schutz z B wechselnder Einbauort Reparatursendung m Achten sie darauf dass das Druckanschluss Gewinde und die Anschlusskontakte nicht besch digt werden Zum Schutz der Membran ist der Druckanschluss des Ger tes F 21 mit einer speziellen Schutzkappe versehen E Entfernen Sie diese Schutzkappe erst kurz vor dem Einbau damit die Membran bzw das Druckanschluss Gewinde nicht besch digt wird E Bewahren Sie die Schutzkappe des Druckanschluss Gewindes und der Membran zur sp teren Lagerung oder Transport auf m Montieren Sie die Schutzkappe bei Ausbau und Transport des Ger tes 7 Inbetriebnahme Betrieb Membran Pr fung zu Ihrer Sicherheit Ben tigtes Werkzeug Maulschl ssel SW 27 Schraubendreher Es ist erforderlich dass Sie vor Inbetriebnahme des Druckmessger tes die Membran optisch pr fen denn sie ist ein sicherheitsrelevantes Teil E Achten Sie auf auslaufende Fl ssigkeit denn sie ist ein Hinweis auf eine Membranbesch digung E Pr fen Sie die Membran optisch auf Besch digung F 21 Warnung E Setzen Sie das Druckmessger t n
16. fo wika co uk Phone 81 3 54 39 66 73 E Mail t shimane wika co jp U S A WIKA Instrument Corporation Phone 1 770 5 13 82 00 E Mail info wika com Further WIKA subsidiaries worldwide can be found online at www wika de Weitere WIKA Niederlassungen weltweit finden Sie online unter www wika de La liste des autres filiales WIKA dans le monde se trouve sur www wika de Otras sucursales WIKA en todo el mundo puede encontrar en www wika de
17. form the transport company and WIKA without delay E Keep the packaging as it offers optimal protection during transportation e g chan ging installation location shipment for repair E Ensure that the pressure connection thread and the connection contacts will not be damaged In order to protect the diaphragm the pressure connection of the instrument F 21 is provided with a special protection cap m Remove this protection cap only just before installing the pressure transmitter in order to prevent any damage to the diaphragm or the thread E Keep the protection cap of the pressure connection thread and the diaphragm for later storage or transport E Mount the protection cap when removing and transporting the instrument 7 Starting operation Required tools wrench flats 27 screw driver Diaphragm test for your safety It is necessary that before starting the pressure transmitter you test the diaphragm visually as this is a safety relevant component E Pay attention to any liquid leaking out for this points to a diaphragm damage u Check the diaphragm visually for any damage F 21 E Use the pressure transmitter only if the diaphragm is undamaged E Use the pressure transmitter only if it is in a faultless condition as far as the safety relevant features are concerned Warning 6 WIKA Operating instructions Betriebsanleitung F 20 F 21 2103870 06 GB D 04 2010 2103870 06 GB D 04 2010 7 Starting opera
18. g instructions before installing and starting the pressure transmitter Keep the operating instructions in a place that is accessible to all users at any time The following installation and operating instructions have been compiled by us with great care but it is not feasible to take all possible applications into consideration These installation and operation instructions should meet the needs of most pressure measurement applications If questions remain regarding a specific application you can obtain further information E Via our Internet address www wika de www wika com E The product data sheet is designated as PE 81 19 E Contact WIKA for additional technical support 49 9372 132 295 With special model number e g F 20000 or F 21000 please note specifications in the delivery note If the serial number and or the 2D code on the hexagon gets illegible e g by mechanical damage or repainting the retraceability of the instrument is not possible any more WIKA pressure transmitters are carefully designed and manufactured using state of the art technology Every component undergoes strict quality and environmental inspection before assembly and each instrument is fully tested prior to shipment Our environmental manage ment system is certified to DIN EN ISO 14001 Use of the product in accordance with the intended use F 20 F 21 Use the pressure transmitter to transform the pressure into an electrical signal Knowledge required Inst
19. h internal spring clip terminals 2 wire U 1 U 2 Test 3 Test 4 screen 5 Wire gauge 7 13 mm Ingress protection per IEC 60 529 RGE The ingress protection classes specified only apply while the pressure transmitter is connected with female connectors that provide the corresponding ingress protection Cable connection in the spring clip terminal E Cover the stripped wire ends with end splices m Unscrew the case cover E Loosen the cable gland using an open end wrench wrench size 24 E Lead the cable through the cable gland into the opened case head E Press the corresponding plastic lever at the spring clip terminal down using a screw driver so that the clamped contact will be released E Lead the prepared flying lead into the opening and let go of the plastic lever so that the flying lead will be squeezed inside the spring clip terminal E After connecting the individual wires tighten the cable gland and screw down the case over Function of the test circuit for 2 wire By means of the test circuit the current can be metered during normal operation without having to disconnect the instrument For that purpose you have to connect an ammeter internal resistance lt 15 Ohm to the test terminals 2103870 06 GB D 04 2010 WIKA Operating instructions Betriebsanleitung F 20 F 21 7 Starting operation 7 Starting operation Specifications Model F 20 F 21 Pressure ranges Over pressure safe
20. icher dass am Ende des Kabels keine Feuchtigkeit eintritt F 20 F 21 WIKA Operating instructions Betriebsanleitung 7 Inbetriebnahme Betrieb 7 Inbetriebnahme Betrieb Elektrischer Anschluss Technische Daten Typ F 20 F 21 24 WIKA Operating instructions Betriebsanleitung F 20 F 21 WIKA Operating instructions Betriebsanleitung F 20 F 21 Feldgeh use innenliegende Federklemmen Messbereich bar 0 1 10 16 0 25 0 4 0 6 1 1 6 12 5 4 6 10 J16 Uberlastgrenze bar 1 LS J2 2 4 5 10 10 liz 852385 280 Berstdruck bar 2 2 2 4 12 4 14 8 6 12 12 20 5 42 42 96 Messbereich bar 25 O 60 100 160 250 400 600 1000 berlastgrenze bar 50 180 120 200 1320 1500 800 1200 1500 Saar Ur 1 U 2 Test 3 Test 4 ee ae Berstdruck bar 96 400 1550 800 1000120017002 2400 3 3000 sieta gt eens Unterdruck berdruck sowie Absolutdruck erh ltlich Kabeldurchmesser 7 13 mm Nur f r Typ F 20 g ltig Schutzart nach 9 Bei Typ F 21 Der Tabellenwert gilt ausschlie lich bei Abdichtung mittels IEC 60 529 IP 67 Dichtring unterhalb vom Sechskant Andernfalls gilt max 1500 bar Die angegebenen Schutzarten gelten nur im gesteckten Zustand mit Leitungssteckern Werkstoff Step LE NENGSRSE MEZ m Messstoffber hrte Teile Andere Werkstoffe siehe WIKA Druckmittler Programm F 20 CrNi Stahl Kabelanschluss u Federklemmblock F 21 CrNi Stahl O Ring NBR FPM FKM
21. ie Betriebsparameter gem Punkt 7 Technische Daten E Beachten Sie die Technischen Daten zur Verwendung des Druckmessger tes in Verbin dung mit agressiven korrosiven Medien und zur Vermeidung von mechanischen Gef hr dungen E Stellen Sie sicher dass das Druckmessgerat nur bestimmungsgem also wie in der folgenden Anleitung beschrieben betrieben wird m Unterlassen Sie unzul ssige Eingriffe und nderungen am Druckmessger t welche nicht in dieser Betriebsanleitung beschrieben sind E Setzen Sie das Druckmessger t au er Betrieb und sch tzen Sie es gegen versehentliche Inbetriebnahme wenn Sie St rungen nicht beseitigen k nnen E Ergreifen Sie Vorsichtsma nahmen f r Messstoffreste in ausgebauten Druckmess ger ten Messstoffreste k nnen zur Gef hrdung von Menschen Umwelt und Einrich tung f hren E Lassen Sie Reparaturen nur vom Hersteller durchf hren E ffnen Sie den Stromkreis bevor Sie den Stecker Deckel abnehmen Warnung Angaben zu Korrosions bzw Diffusionsbest ndigkeit der Ger tewerkstoffe entnehmen Sie bitte unserem WIKA Handbuch zur Druck und Temperaturmesstechnik F 20 F 21 20 WIKA Operating instructions Betriebsanleitung rung und spezifischen Messbedingungen vor Montage oder Inbetriebnahme 2103870 06 GB D 04 2010 2103870 06 GB D 04 2010 6 Verpackung 7 Inbetriebnahme Betrieb 6 Verpackung Wurde alles geliefert Uberpr fen Sie den Lieferumfang E Komplett monti
22. instructions Betriebsanleitung F 20 F 21 10 St rbeseitigung B Pr fen Sie bitte vorab ob Druck ansteht Ventile Kugelhahn usw offen und ob Sie die richtige Spannungsversorgung und die richtige Verdrahtungsart 2 Leiter 3 Leiter gew hlt haben Ma nahme M gliche Ursache Keine Falsche Versorgungsspannung oder Stromsto Leitungsbruch Verdrahtungsfehler z B 2 Leiter als 3 Leiter verdrahtet Mechanische berlastung durch Versorgungsspannung gem Betriebs anleitung korrigieren Durchgang berpr fen Anschlussbelegung beachten siehe Typenschild Betriebsanleitung Ger t austauschen bei wiederholtem Kein Ausgangssignal Kein Falsches Ausgangssignal Gleichbleibendes Ausgangssignal bei Druck nderung berdruck Ausfall R cksprache mit Hersteller Falsche Versorgungsspannung oder EEE ET Stromsto Abweichendes Nullpunkt Signal Bei Justage Spanne verstellt Geeignete Referenz benutzen Membranbesch digung z B durch Schl ge abrasives agressives Medium Hersteller kontaktieren und Ger t Korrosion an Membran Druckan austauschen schluss bertragungsmedium fehlt Dichtung Dichtfl che besch digt verschmutzt Dichtung sitzt unkorrekt Gewindeg nge verkantet Feuchtigkeit eingetreten z B am Kabelende Signalspanne zu klein f llt ab Dichtung Fl che s ubern evtl Dich tung austauschen Kabel korrekt montieren Versorgungsspannung gem Betriebs anleit
23. isse Montieren und nehmen Sie das Druckmessger t nur in Betrieb wenn Sie mit den zutreffenden landesspezifischen Richtlinien vertraut sind und die entsprechende Qualifikation besitzen Sie m ssen mit den Kenntnissen von Mess und Regeltechnik sowie elektrischen Stromkreisen vertraut sein Je nach Einsatzbedingung m ssen Sie ber entsprechendes Wissen verf gen z B ber agressive Medien bzw hohe Dr cke 2 Der schnelle berblick f r Sie Wollen Sie sich einen schnellen berblick verschaffen lesen Sie Kapitel 3 5 7 und 11 Dort erhalten Sie kurze Hinweise zu Ihrer Sicherheit und wichtige Informationen ber Ihr Produkt und zur Inbetriebnahme Lesen Sie diese unbedingt 18 WIKA Operating instructions Betriebsanleitung F 20 F 21 2103870 06 GB D 04 2010 2103870 06 GB D 04 2010 3 Zeichenerklarungen Abk rzungen 4 Funktion 3 Zeichenerklarungen Abkurzungen M gliche Gefahr fur Ihr Leben oder schwerer Das Produkt stimmt mit den zutreffenden europ ischen Warnung Verletzungen Richtlinien berein M gliche Gefahr f r Ihr Hinweis wichtige Informa FAN Leben oder schwerer Verlet tion Funktionsst rung W zungen durch wegschleu a dernde Teile M gliche Gefahr von AN Verbrennungen durch Vorsicht heisse Oberfl chen 2 Leiter Zwei Anschlussleitungen dienen zur Spannungsversorgung Der Speisestrom ist das Mess Signal 3 Leiter Zwei Anschlussleitungen dienen zur Spannungsversorgung Eine Anschlusslei
24. itung 1 Wichiges zu Ihrer Information 2 Schneller berblick 1 Wichtiges zu Ihrer Information Lesen Sie diese Betriebsanleitung vor Montage und Inbetriebnahme des Druckmessger tes Bewahren Sie die Betriebsanleitung an einem f r alle Benutzer jederzeit zug nglichen Ort auf Die nachfolgenden Einbau und Betriebshinweise haben wir mit Sorgfalt zusammengestellt Es ist jedoch nicht m glich alle erdenklichen Anwendungsfalle zu ber cksichtigen Sollten Sie Hinweise f r Ihre spezielle Aufgabenstellung vermissen k nnen Sie hier weitere Informationen finden m Uber unsere Internet Adresse www wika de www wika com E Die Bezeichnung des zugeh rigen Datenblattes ist PE 81 19 m Anwendungsberater 49 9372 132 295 Bei Sondertypennummer z B F 20000 oder F 21000 beachten Sie die Spezifikationen gem Lieferschein Wird die Seriennummer und oder der 2D Code auf dem Sechskant unleserlich z B durch mechanische Besch digung oder Ubermalen ist eine R ckverfolgbarkeit nicht mehr m glich Die in der Betriebsanleitung beschriebenen WIKA Druckmessger te werden nach den neuesten Erkenntnissen konstruiert und gefertigt Alle Komponenten unterliegen w hrend der Fertigung strengen Qualit ts und Umweltkriterien Unser Umweltmanagementsystem ist nach DIN EN ISO 14001 zertifiziert Bestimmungsgem e Produktverwendung Verwenden Sie den Druckmessumformer um Druck in ein elektrisches Signal zu wandeln Ihre erforderlichen Kenntn
25. ng surface for screwing in or unscrewing the instrument E When screwing the transmitter in ensure that the threads are not jammed E For tapped holes and welding sockets please see Technical Information IN 00 14 for download at www wika de WIKA Operating instructions Betriebsanleitung F 20 F 21 7 Starting operation Electrical connection m Connect the instrument to earth via the pressure connection and or connection terminal 5 E Operate the pressure transmitter with a shielded cable and earth the shield at least on one side of the cable if the cable is longer than 30m 2 wire or 3m 3 or 4 wire or if it is run outside of the building E Ingress protection per IEC 60529 The ingress protection classes specified only apply while the pressure transmitter is connected with female connectors that provide the corresponding ingress protection E Ensure that the cable diameter you select fits to the cable gland of the connector Ensure that the cable gland of the mounted connector is positioned correctly and that the sealings are available and undamaged Tighten the threaded connection and check the correct position of the sealings in order to ensure the ingress protection m Please make sure that the ends of cables with flying leads do not allow any ingress of moisture 8 WIKA Operating instructions Betriebsanleitung F 20 F 21 2103870 06 GB D 04 2010 7 Starting operation Wiring details Field case wit
26. on about the problem Pressure transmitters received by WIKA without a valid RMA number will not be accepted Process material certificate Contamination declaration for returned goods Purge clean dismounted instruments before returning them in order to protect our employees and the environment from any hazard caused by adherent remaining media Service of instruments can only take place safely when a Product Return Form has been submitted and fully filled in This Return Form contains information on all materials with which the instrument has come into contact either through installation test purposes or cleaning You can find the Product Return Form on our internet site www wika de www wika com 11 Storage disposal When storing or disposing of the pressure transmitter take precautions with A regard to remaining media in removed pressure transmitters We recom Warning mend cleaning the transmitter properly and carefully Remaining media in the pressure port may be hazardous or toxic Storage Mount the protection cap when storing the pressure transmitter in order to prevent any damage to the diaphragm F 21 Disposal Dispose of instrument components and packaging materials in accordance with the respective waste treatment and disposal regulations of the region or country to which the instrument is supplied WIKA reserves the right to alter these technical specifications F 20 F 21 WIKA Operating instructions Betriebsanle
27. present e g at the cable tail In case of unjustified reclamation we charge the reclamation handling expenses Make sure that after the setting the unit is working properly In case the error continues to exist send in the instrument for reparation or replace the unit 16 WIKA Operating instructions Betriebsanleitung F 20 21 Procedure Adjust the voltage supply to correspond with the Operating Instructions Check connections and cable Follow pin assignment see Instrument Label Operating Instructions Replace instrument if failure reoccurs consult the manufacturer Replace instrument Use appropriate reference Contact the manufacturer and replace the instrument Clean the seal sealing face possibly replace the seal Install the cable correctly Correct the power supply in line with the Operating Instructions Re calibrate the instrument Shield the device shield the cables remove the interference source Replace instrument Install the cable correctly 2103870 06 GB D 04 2010 2103870 06 GB D 04 2010 10 Trouble shooting 11 Storage disposal If the problem persists contact our sales department USA Canada If the problem continues contact WIKA or an authorized agent for assistance If the pres sure transmitter must be returned obtain an RMA return material authorization number and shipping instructions from the place of purchase Be sure to include detailed informati
28. pressure ranges up to 25 bar Response time for model F 21 lt 10 ms at medium temperatures below lt 30 C 22 F of span of span 0 80 C 32 176 F lt 0 2 10 K lt 0 4 for pressure range lt 250 mbar 100 INWC 0 2 7 101K CE conformitiy m Pressure equipment directive WIKA Operating instructions Betriebsanleitung This instrument is a pressure accessory as defined by the directive 97 23 EC F 20 F 21 7 Starting operation Specifications Model F 20 F 21 7 Starting operation Functional test The output signal must be proportional to the pressure If not this might point to a m EMC directive T A PE 326 Emission Group 1 Class B and Immunity damage of the diaphragm In that case refer to chapter 10 Troubleshooting Shock resistance 600 according to IEC 60068 2 27 mechanical shock m Open pressure connections only after the system is without pressure Vibration resistance 10 according to IEC 60068 2 6 vibration under resonance m en the ambient and working conditions outlined in section 7 Technical ata Wiring protection Warnin ae u I m Please make sure that the pressure transmitter is only used within the over m Short circuit proofness S towards U ibad threshold limitat alltime m Reverse polarity protection U towards U f ee Eh aise When touching the pressure transmitter Keep in mind that the surfaces of e rox U
29. ten Material Gewinde und Dichtung gelten WIKA Operating instructions Betriebsanleitung F 20 F 21 7 Inbetriebnahme Betrieb 8 Einstellung Nullpunkt Spanne Funktionspr fung Das Ausgangssignal muss sich dem anstehenden Druck proportional verhalten Wenn dies nicht so ist kann das ein Hinweis auf eine Besch digung der Membran sein Lesen Sie in diesem Fall in Kapitel 10 St rbeseitigung nach m ffnen Sie Anschl sse nur im drucklosen Zustand EN E Beachten Sie die Betriebsparameter gem Punkt 7 Technische Daten E Betreiben Sie das Druckmessger t immer innerhalb des berlastgrenzbe Warnung reichs Beachten Sie beim Ber hren des Druckmessger tes dass die Oberfl chen AN der Ger tekomponenten w hrend des Betriebes hei werden k nnen Vorsicht Einstellung Nullpunkt Spanne Wir empfehlen Ihnen das Spannepotentiometer nicht zu verstellen Es dient zur werk seitigen Justage und sollte nur von Ihnen verstellt werden wenn Sie ber die ausrei chende Kalibrierausstattung mindestens 3x genauer als die angegebene Genauigkeit verf gen E Achten Sie bei der Steckerdemontage montage darauf dass keine Litzen abgerissen bzw eingequetscht werden m ffnen Sie das Druckmessger t indem Sie das Feldgeh use aufdrehen E Stellen Sie den Nullpunkt Z ein indem Sie den Druckanfangswert anfahren E Stellen Sie die Spanne S ein indem Sie den Druckendwert anfahren E berpr fen Sie
30. tion Mechanical connection Product label example wikal Ge F 0 10 bar amp 4 20 mA i 2 I Fe te mA a4 d 5 DG11 30V gt w 0639110 Pw 0639080 WHA Aandi Wiegand eb amp CoN 6307 Mingenbesg Geneiey at T max gt Signal 50 Nm Test Test circuit connection _ um gt Power Supply SB gun S Serial No P Product No PIN assignment Coded manufacture date Generally the serial number on the product label applies If there is no serial number on the product label the number on the hexagon will apply E Remove the protection cap only just before installation and absolutely avoid any damage to the diaphragm during installation as well F 21 E For Model F 20 you have to provide for a sealing element exceptions are instruments with self sealing threads e g NPT thread For Model F 21 the sealing is included in delivery E Please refer to our data sheet Pressure gauge sealing washers AC 09 08 in WIKA s product catalog Pressure and Temperature Measurement or our website www wika de for details about sealing washers E When mounting the instrument ensure that the sealing faces of the instrument and the measuring point are clean and undamaged E Screw in or unscrew the instrument only via the flats using a suitable tool and the prescribed torque The appropriate torque depends on the dimension of the pressure connection and on the sealing element used form material Do not use the case as worki
31. tung dient f r das Mess Signal U Positiver Versorgungsanschluss U Negativer Versorgungsanschluss S Positiver Messanschluss 4 Funktion F 20 Druckanschluss mit innenliegender Membran Standardausf hrung F 21 Druckanschluss mit frontb ndiger Membrane f r hochviskose oder kristallisierende Medien die die Bohrung des Druckanschlusses zusetzen k nnen Funktion Mittels Sensorelement und unter Zuf hrung von Hilfsenergie wird ber die Verfor mung einer Membran der anstehende Druck in Ihrer Anwendung in ein verst rktes standardi siertes elektrisches Signal umgewandelt Dieses elektrische Signal ver ndert sich proportional zum Druck und kann entsprechend ausgewertet werden F 20 F 21 WIKA Operating instructions Betriebsanleitung 5 Zu lhrer Sicherheit 5 Zu Ihrer Sicherheit E Wahlen Sie das richtige Druckmessger t hinsichtlich Messbereich Ausf h E Halten Sie die entsprechenden landesspezifischen Vorschriften ein z B EN 50178 und beachten Sie bei speziellen Anwendungen die geltenden Normen und Richtlinien z B bei gef hrlichen Messstoffen wie Acetylen brennbaren oder giftigen Stoffen sowie bei K lteanlagen und Kompres soren Wenn Sie die entsprechenden Vorschriften nicht beachten k nnen schwere K rperverletzungen und Sachsch den entstehen m ffnen Sie Anschl sse nur im drucklosen Zustand E Betreiben Sie das Druckmessger t immer innerhalb des berlastgrenzbereiches E Beachten Sie d
32. ty Burst pressure Pressure ranges Over pressure safety Burst pressure bar 0 1 0 16 10 25 10 4 0 6 1 1 6 2 5 4 6 10 16 bar 1 1 972 2 4 5 107 10 Ae les ke 160 bar 2 2 2 4 12 4 48 16 12 12 20 5 42 42 96 bar 25 140 60 100 1160 250 400 600 1000 bar 50 80 120 200 320 500 800 1200 1500 bar 96 400 550 800 1000 1200 1700 2400 3000 Vacuum gauge pressure compound range absolute pressure are available 10 Only model F 20 2 For model F 21 the value specified in the table applies only when sealing is realised with the sealing ring underneath the hex Otherwise max 1500 bar applies Materials m Wetted parts F 20 F 21 m Case E Electrical connection Internal transmission fluid Other materials see WIKA diaphragm seal program Stainless steel Stainless steel O ring NBR FPM FKM Stainless steel With internal spring clip terminal cross section max 2 5 mm ground terminals internal for brass nickel plated and stainless steel and stainless steel conduit threaded connection Synthetic oil 3 Not for model F 20 with pressure ranges gt 25 bar 300 psi m Power supply U Signal output and maximum ohmic load RA 10 WIKA Operating instructions Betriebsanleitung DC V 10 30 14 30 with signal output 0 10 V 11 30 with signal output 4 20 mA RAinOhm l4 20 mA 2 wire RA lt U 10V 0 02 A 0
33. ung korrigieren Ger t austauschen bei wiederholtem Versorgungsspannung zu hoch niedrig Mechanische berlastung durch berdruck Ausfall R cksprache mit Hersteller EMV St rquellen in Umgebung z B Ger t abschirmen Leitungsabschir Signalspanne schwankend er Frequenzumrichter mung St rquelle entfernen Membranbesch digung z B durch Schl ge abrasives agressives Medium Ger t austauschen Korrosion an Membran Druckanschluss Abweichendes Nullpunkt Signal Feuchtigkeit eingetreten z B Kabe lende Nullpunktsignal instabil zu niedrig hoch Kabel korrekt montieren Im unberechtigtem Reklamationsfall berechnen wir die Reklamationsbearbeitungs Kosten berpr fen Sie nach dem Justieren die korrekte Arbeitsweise des Systems Besteht der Fehler weiterhin senden Sie das Ger t zur Reparatur ein oder tauschen Sie das Ger t aus F 20 F 21 30 WIKA Operating instructions Betriebsanleitung 2103870 06 GB D 04 2010 2103870 06 GB D 04 2010 11 Lagerung Entsorgung D Wenn das Problem bestehen bleibt setzen Sie sich mit unserem Vertriebsmitarbeiter in Verbindung Prozess Material Zertifikat Kontaminationserkl rung im Servicefall Sp len bzw s ubern Sie ausgebaute Ger te vor der R cksendung um unsere Mitarbeiter und die Umwelt vor Gef hrdung durch anhaftende Messstoffreste zu sch tzen Eine berpr fung ausgefallener Ger te kann nur sicher erfolgen wenn das vollst ndig ausge f llte R
34. ur ein wenn die Membran unbesch digt ist E Setzen Sie das Druckmessgerat nur in sicherheitstechnisch einwandfreiem Zustand ein WIKA Operating instructions Betriebsanleitung F 20 F 21 7 Inbetriebnahme Betrieb Montage mechanischer Anschluss Typenschild Beispiel WIKA cE Transma FA ae ae fung EN Ge MG ac gt gt Signal Test Testkreisanschluss gt Spannungsversorgung S Serien Nr P Erzeugnis Nr Anschlussbelegung Codiertes Herstelldatum EW Kimgsmturg Gemeng Es gilt grunds tzlich die Seriennummer auf dem Typenschild Befindet sich keine Seriennummer auf dem Typenschild so gilt die Nummer auf dem Sechskant E Entfernen Sie die Schutzkappe erst kurz vor dem Einbau und achten Sie unbedingt darauf dass die Membran auch w hrend des Einbaus nicht besch digt wird F 21 E Bei Typ F 20 m ssen Sie eine Dichtung vorsehen Ausnahme sind Ger te mit selbst dichtendem Gewinde z B NPT Gewinde Bei Typ F 21 ist der Dichtring im Liefer umfang enthalten E Hinweise zu Dichtungen entnehmen Sie bitte unserer Information Zubeh r Dich tungen AC 09 08 im Gesamtkatalog Druck und Temperaturmesstechnik oder unserer Internet Seite unter www wika de E Achten Sie bei der Montage auf saubere und unbesch digte Dichtfl chen am Ger t und Messstelle E Schrauben Sie das Ger t nur ber die Schl sselfl chen mit einem geeigneten Werk zeug und dem vorgeschriebenen Drehmoment ein bzw
35. utlined in section 7 Technical data E Observe the technical data for the use of the pressure transmitter in connection with aggressive corrosive media and for the avoidance of mechanical hazards E Ensure that the pressure transmitter is only operated in accordance with the provisions i e as described in the following instructions E Do not interfere with or change the pressure transmitter in any other way than described in these operating instructions m Remove the pressure transmitter from service and mark it to prevent it from being used again accidentally if it becomes damaged or unsafe for operation E Take precautions with regard to remaining media in removed pressure transmitter Remaining media in the pressure port may be hazardous or toxic m Have repairs performed by the manufacturer only E Open circuit before removing connector cover Warning Information about material consistency against corrosion and diffusion can be found in our WIKA Handbook Pressure and Temperature Measurement WIKA Operating instructions Betriebsanleitung F 20 F 21 6 Packaging 7 Starting operation 6 Packaging Has everything been supplied Check the scope of supply E Completely assembled pressure transmitters E With flush version F 21 including pre assembled sealings and protection cap E Inspect the pressure transmitter for possible damage during transportation Should there be any obvious damage in