Home

Operating Instructions SMV 04 Update

image

Contents

1. ag a a PLAST g WPSG SERVICE GMBH Operating Instructions PSG Plastic Service GmbH P O Box 42 01 62 68280 Mannheim Germany Phone 49 621 71620 Fax 49 621 7162 162 www psg online de info psg online de Update SMV 04 CE Rev 0 1 3 11 2009 PSG Plastic Service GmbH 1 Operating Instructions SMV 04 Update EEE EE EE NK NE A 2 Ze 000 go EEE EE EE EE 7 GE 0 oa 0 EE EE EE RE RE 7 Right to technical changes reserved Rev 0 1 3 2 Chapter 1 Installation 1 Installation Install the Atmel Software on directory Atmel Setup exe on the attached CD ROM Step 1 Switch off 230 V voltage Remove the two fuses F1 and F2 on the SMV 04 module Step 2 DIP switch setting for CAN current interface CAN STI Put DIP switch 5 to ON The sending of control information to the SMV 04 modules is interrupted Step 3 Attachment of program adapter AT COM The SMV 04 module exists in two models e Revision 1 without LEDs e Revision 2 with LEDs for status indication of controller outputs The program adapter is attached to the appropriate SMV 04 model as shown in the following two pictures pemektaees g SSSR Bceee TE Tab BEER SNP Tuna van lt p geet S 288668 Figure 2 SMV 04 with LEDs Right to technical changes reserved Rev 0 1 3 PSG Plastic Service GmbH 3 Operating Instructions SMV 04 Update Step 4 Start update software for SMV 04 Controller f Atm
2. Version History Version Date Changes 0 1 3 11 12 2009 In detail the following amendments were made e Installation step 1 2 changed e Flip 2 4 2 amended e Controller type changed T89C51RD2 gt AT89C51ED2 e Reset before Connect amended 0 1 2 05 10 2005 Feasible baud rate 19200 0 1 1 07 07 2005 Serial interface process abort supplemented 0 1 17 06 2005 First release Right to technical changes reserved Rev 0 1 3
3. el Flip 2 27 4 File Buffer Device Settings Help Start update software Flip Use Flip 2 4 2 Buffer Information Size G Ebytes Blank FF M Erase Range 0000 FFFF Checksum Ae Offset 0000 Reset Before Loading yf ile M Program ae o leit Mo device selected f Verify AMEL iii Runf Clear Step 5 Selection of controller type f Atmel Flip 2 2 4 File B E Device tings Help Select device Buffer Information Size B4 Kbytes Blank FF Range 000D FFFF Checksum A Offset 000 Reset Before Loading a ile E ioan HE File NONE Mo device selected IY Verify AMEL n A Run Clear 7 Device Selection x Select type AT89C51ED2 Right to technical changes reserved Rev 0 1 3 OK Cancel 4 Chapter 1 Installation Step 6 HEX file load menu Atmel Flip 2 2 4 Fletter Devic Settings Help Load HEX File Buffer Information T35C51B8D2 Sze 63 Kbytes Signature Bytes P Blank FF Device Boot Ids ao Range 0000 FBFF ox Checksum FBO400 Offset 0000 Bootloader Ver ET W Blank Check Reset Before Loading BSE SBY ex x Hardware Bute 7 Program HEX File Device SSB a Level Level Level 2 f Verify Rur Clear Step 7 File selection SMV04 HEX Metzwerkumq Right to technical changes reserved Rev 0 1 3 D ateiname s MYO4 r Dateitpp Hes Files hex HEX Hex Abbrechen File on CD ROM PSG Plastic Service GmbH 5 Operating Ins
4. ntroller type E T89C51RD2 and change it if 7 Program HEX File SMVDA hex Deng eds FF necessary 8 8 Kbytes fr Leveld l C Level Verify MEL p Start again with Run Level MADRE e If controller type is ok deactivate Blank Check Start again with Run HEX file SMYO4 hex loading dot Step 10 Completion of programming f Atmel Flip 2 2 4 ioj xj File Buffer Device Settings Help View after successful programming Operations Flow Buffer Information Size 63 kbytes Blank FF Device Boot Ids M Erase Range 0000 2334 Checksum 1040CF Offset 0000 Reset Before Loading ESB SBYV Signature Bytes Hardware Byte Bootloader Ver M Blank Check M Program HEX File SMYOM hex Device 58 0 0 Kbytes Level d Level E Verify AMEL c REESE Run Clear Memory verity pass Software start after remove of program adapter AT COM After successful update of all SMV 04 modules connected to CAN STI put DIP switch 5 to OFF Step 11 Potentiometer measurement of end position After completion of programming the potentiometer measurement of end position has to be done according to the instructions of data sheet Serve valve module SMV 04 Recommendation After completion of all steps put a label with firmware version onto SMV 04 module Right to technical changes reserved Rev 0 1 3 PSG Plastic Service GmbH 7 Operating Instructions SMV 04 Update 2 Appendix 2 1
5. tructions SMV 04 Update Step 8 Select communication settings f Atmel Flip 2 2 4 File Buffypevce Selling Help Operations Flow Buffer Information Size Ba Ebytes Blank FF Range 0000 FBFF Checksum FBO400 is Offset 0000 Reset Before Loading BSB SBY Signature Bytes Device Boot Ids Hardware Bute Bootloader Ver W Blank Check f Program HEX File Bars elt Leveld Level Verify A MEL Level SEES i Runf Clear Step 9 Select serial interface Select interface type RS232 ES 5 x Part COMT 4 Select COMPORT dependant on PC e g COM1 Baud 35400 Select baud rate 38400 or baud rate 19200 Manual Sync Connect Disconnect Sync Cancel Press RESET at AT COM adapter ES 5 xi Part COM Establish interface connection pressing the button Connect Baud 36400 Manual Sync Disconnect SFI Cancel Right to technical changes reserved Rev 0 1 3 Chapter 1 Installation 6 f Atmel Flip 2 2 4 SI iol x File Buffer Device Settings Help After a successful connection build up all processing steps are labelled with a Buffer Information q T83C51AD2 L check mark e e Signature Bytes se 7FFFE Ea 7 Erase EE Device Boot Ids 0000 Start of processing by clicking on Run ange Checksum 10400F ped fo De Offset 0000 Bootloader Ver feo If processing aborts ai Reset Before Loading BSB SBV oo FC e Check co