1.  and reduce the life expectancy  of the air curtain      Once the mains supply is isolated  remove the grille  this is done by removing the four cross  head screws and lifting the grille clear  access can now be gained to the air curtain    Vacuum and clean the built up dirt and debris within the air curtain  please note that the  motor s  and bearings are permanently sealed and require no additional lubrication   Re install  the grille  reconnect the power and fully function test the air curtain to ensure correct operation     e Warranty    lf any problems are encountered  please contact your installer supplier failing this please  contact the Thermoscreens warranty department     Thermoscreens Ltd  St  Mary   s Road  Nuneaton  Warwickshire  England   CV11 5AU    Tel   44  0  24 7638 4646  Fax   44  0  24 7638 8578    Email  sales thermoscreens com    www thermoscreens com    Engineering change number  03 00092 Dwg No  4007100 1  Issued  16 01 04    
2. 1P amp N  1 5 3 0kW 7 5kg  T800ER 230V 50Hz 1P amp N  3 0 4 5kW 8 5kg    To gain access to the electrical connections the recessed grille must be removed  the grille is  secured to the frame of the air curtain via 4 cross head screws  to remove the grille from the unit  remove the screws and lift the grille clear  access can be gained to the mains supply  amp  remote  switch terminals inside the air curtain  located at the left hand end of the unit     Four sets of cable entry holes are provided  20mm knock outs  within the casing  two via the  end cap for side entry  amp  two via the back case for top entry  Once the appropriate cable entry  glands have been fitted  to be supplied by installer in accordance to the latest edition of IEE  regulations or local regulations in use  proceed to connect the supply remote switch to the unit  as per the attached wiring diagram  when fitting the remote switch ensure that it is located in a  Suitable place for easy access     e Operation    All units are supplied with a remote switch that gives the following functions  On off  amp  two heat  settings  for heat output see above table      For thermostatic control a room thermostat maybe connected in series with terminal 4 to give  control over the second stage of heat     e Fault conditions    In the event of a fault the thermal cut out or the internal fuse may operate  The thermal cut out is  located at the left hand end of the unit  the internal fuse is located within the terminals mou
3. Page l of 5  WORLDWIDE SUPPLIERS    THERMOSCREENS    OF AIR CURTAINS             THERMOSCREENS RECESSED RANGE    FOR INDOOR USE ONLY    INSTALLATION AND OPERATING INSTRUCTIONS    PLEASE READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING INSTALLATION        Engineering change number  03 00092 Dwg No  4007100 1  Issued  16 01 04    Page 2 of 5    UN PACKING YOUR RECESSED AIR CURTAIN    The following items are supplied     e RECESSED AIR CURTAIN       e REMOTE SWITCH UNIT  C W 3 0m lead    The remote switch unit is   located inside of the air   curtain         e RECESSED GRILLE       If anything is missing or damaged please contact your place of purchase immediately     For your records    Date of purchase    S  Place of purchase    o  Serial Number  a    For warranty purposes  proof of purchase is necessary  so please keep a copy of your  invoice      Please note that all documentation remains the property of the building and should be stored  accordingly     Engineering change number  03 00092 Dwg No  4007100 1  Issued  16 01 04    Page 3 of 5  INSTALLATION OF YOUR T600ER  amp  T800ER UNIT    e Location    The T600ER  amp  T800ER are designed for recessing mounting within a ceiling void or bulkhead   minimum height of 1 8     to maximum height of 2 3m    When mounting ensure that the air discharge is situated as close to the door as possible  the  T600ER  amp  T800ER are designed to fit directly into a ceiling tile grid formation  T600ER      595mm  I  to suit 600mm grid  amp  the 
4. T800ER 895mm  I  to suit 900mm grid  if the grid does not  align with the door then the grid will need modifying     Note  an air gap of 50mm is required around the external casing   e Ceiling suspension    Each unit is provided with 4 x M6 inserts  two either end  to allow the unit to be suspended via  threaded rods or wire tie  see figure 1 below     Please note when fixing using threaded rods or wire ties  not supplied  that a suitable structure  is used ensuring that it can maintain the unit weight adequately  for unit weights see table 1    Ensure that locking nuts are fitted  not supplied  to stop the threaded bar wire ties rotating and  coming away from the casing    For dimensions of fixing centres please see figure 1 below     Figure 1    4x M6  INSERTS    T600 T800                         CABLE ENTRY    CABLE ENTRY    EANN ae    AIR  DISCHARGE       Engineering change number  03 00092 Dwg No  4007100 1  Issued  16 01 04    Page 4 of 5  e Electrical connections  WARNING     Units should only be wired by a competent electrician in accordance with the latest  edition of the IEE wiring regulations and or local statutory regulations     Ensure that the supply cables and circuit breakers are sufficient for the air curtain s  being  installed  for electrical loading see table 1 below      A single phase isolator rated appropriately must be fitted to the supply wiring with a contact  separation of at least 3mm     Table 1    Supply Heat output Weight       T600ER 230V 50Hz 
5. nted  at the left hand end     In the case of a fault condition do not attempt to reset the thermal cut out or replace the fuse   arrange for a Thermoscreens appointed engineer or certified electrician to attend the unit to  investigate the reason why the thermal cut outs fuse have operated  once the cause has been  determined and rectified  proceed to reset replace the thermal cut out fuse and function test the  unit     Engineering change number  03 00092 Dwg No  4007100 1  Issued  16 01 04    Page 5 of 5    e Air flow    When installing the  air curtain ensure  that the air stream  is as close to the  door opening as  possible to give  optimum  performance  see  figure inset      AIR INTAKE                               e Service  amp  Maintenance    Always disconnect solate the mains electricity supply before maintaining or repairing  this equipment  Note  All maintenance repairs should be carried out by a competent  electrician or Thermoscreens service agent     To ensure the air curtain operates at full efficiency the inlet outlet grilles  impellers  housings  and motors must be kept free of dust and debris  Build up of dust on the impellers can cause  vibration  noise and excessive wear on the impeller motor bearings     Frequency of cleaning will depend on the environment  but we would recommend that the unit  be cleaned a minimum of every 3 months  failure to adequately maintain the unit and provide a  Suitable cleaning schedule will result in performance degradation
    